DOLPHIN 105

DOLPHIN 105 is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 88 inspections since 1982, most recently in December 2003, along with 206 deficiencies — 6 with no resolution recorded — and 3 casualty investigations between 2000 and 2002.

Records from 1982 to 2003. Most recent: inspection, 12 December 2003.

Built
1982
Last inspected
12 December 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8750998 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCJ7761
Flag
UNITED STATES
—
Maury page id
psix-54705

Inspections, by type

…with no type recorded24
…past their stated due date6
Years with a record 22 calendar years (1982–2003)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it943 - Regulatory (Subpart C or D), Gross Ton
943 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCJ7761MMSI not assigned · cancelled · voluntarily equipped · granted 15 July 1994, cancelled 14 June 2002
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

C - CARRIER Offshore Supply Vessel · MISLE 468539 · 16 October 2001 · activity 163456GB BALAM Freight Ship · MISLE 242732 · 1 August 2000 · activity 7175

Inspection history · 88

12 December 2003 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1963206
31 October 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1939626
14 April 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2001600
3 October 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1685875
3 October 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1698891
16 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 163456
6 September 2001 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1410684
28 August 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072558
14 August 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069995
9 July 2001 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1412334
1 March 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1057997
9 January 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 825111
24 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823914
10 October 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1057208
25 August 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444399
1 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7175
1 August 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466707
14 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053265
9 December 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812311
8 September 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458675
27 August 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116680
4 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803260
16 April 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122883
29 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779869
21 September 1998 Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444053
19 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 156923
17 July 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128281
9 July 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459434
8 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123284
12 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785754
9 September 1997 COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1430456
7 May 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 34649
17 April 1997 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400563
20 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093619
27 November 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873856
12 November 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 862565
10 September 1996 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459259
4 January 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1187051
20 December 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 871658
14 September 1995 COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1363383
1 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854513
20 September 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385300
22 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 856939
9 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162843
16 September 1993 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434046
11 January 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 830805
8 October 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933237
30 September 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949880
30 September 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260103
21 September 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1255257
17 September 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947616
17 June 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944965
24 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268191
25 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935257
21 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253411
15 October 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939858
20 September 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 941094
13 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904684
7 March 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239920
13 February 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905922
31 January 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303718
15 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918889
27 December 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917410
14 November 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931513
11 October 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 929521
17 January 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904572
4 December 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916063
11 October 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007768
28 April 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034771
20 December 1988 Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1038606
20 December 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350592
13 October 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206946
29 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 886502
27 June 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895283
8 June 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893831
23 May 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1195213
16 March 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966971
15 October 1987 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317361
28 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024535
23 April 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320544
14 October 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1013382
2 January 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996088
2 December 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992583
23 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975288
13 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975385
11 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976511
6 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276833
31 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965859

Deficiency record · 206

Construction/Loadline
Issued 9 July 2001 Resolved
CROP AND RENEW WASTED BIT PORT SIDE AFT.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Fire Fighting
Issued 9 July 2001 Resolved
CROP AND RENEW WASTED AND HOLED FIRE MAIN PIPING AT FM STATION #11.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Construction/Loadline
Issued 9 July 2001 No resolution recorded
CROP AND RENEW UNDERDECK LONGS OF HELIPORT.
Condition: Unknown
Due 9 November 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 July 2001 No resolution recorded
CROP AND RENEW WASTED VERTICAL FRAMES IN TANKS #1S WING BALLAST AND #6S WING BALLAST, AND UNDERDECK LONGS IN #6S WING BALLAST.
Condition: Unknown
Due 9 November 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 July 2001 No resolution recorded
CROP AND RENEW TRIPPED/TWISTED VERTICALS IN #1S OUTBOARD BALLAST, #6P OUTBOARD DRILLWATER (INBOARD BULKHEAD), AND #1P WING BALLAST.
Condition: Unknown
Due 9 November 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 July 2001 No resolution recorded
CONDUCT PHASE II SEILODD.
Condition: Unknown
Due 9 November 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 July 2001 No resolution recorded
CROP AND RENEW WASTED PORTION OF LOWER BULKHEAD IN #5P WING VOID COMMON WITH LAUNDRY ROOM. REPAIR TO GOOD STEEL.
Condition: Unknown
Due 9 November 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 July 2001 No resolution recorded
MAKE READY FOR INTERNAL INSPECTION PORT SIDE OF COFFERDAM.
Condition: Unknown
Due 9 November 2001 — due date passed with no resolution recorded
Electrical
Issued 9 July 2001 Resolved
REPAIR/REPLACE HOLED BATTERY BOX AT HELIPORT.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Electrical
Issued 25 August 2000 Resolved
INSTALL LINING IN BATTERY BOXES IAW 46CFR111.15-5
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Lifesaving
Issued 25 August 2000 Resolved
PROVE PROPER OPERATION OF FIRE ALARM SYSTEM AT ELECTRICAL CONTROL ROOM, 01 DECK FORWARD BOW AND MAIN DECK STBD AFT.
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Unknown
Issued 1 August 2000 Resolved
PRIOR TO COMMENCING DRILLING OPERATIONS OR MOVING, PROVIDE TO THE SATISFACTION OF THE [name withheld], THE STRUCTURAL INTEGRITY OF RIG'S: UPPER HULL, LEG TO MAT CONNECTIONS, LEGS, CANTILEVER SUPPORTS AND MAT.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Lifesaving
Issued 8 September 1999 Resolved
CONDUCT 1.1 RELEASE GEAR TEST FOR LIFEBOAT RELEASE GEAR OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL [name withheld] IN WATER OPERATION OF LIFEBOAT TILL TEST IS COMPLETED.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Lifesaving
Issued 21 September 1998 Resolved
REPLACE ALL PAINTED OR SAND BLASTED HELO DECK LIGHTS.
Condition: Unknown
Due 8 October 1998
Resolved 9 October 1998
Lifesaving
Issued 21 September 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 October 1998
Resolved 9 October 1998
Lifesaving
Issued 21 September 1998 Resolved
REPLACE AS NEEDED ALL DAMAGED LIFE RINGS.
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998
Unknown
Issued 21 September 1998 Resolved
POST FUEL TRANSFER PROCEDURES AT FUEL TRANSFER STATION AS PER 33CFR155.720.
Condition: Unknown
Due 8 October 1998
Resolved 9 October 1998
Electrical
Issued 21 September 1998 Resolved
REPLACE/REPAIR CAP ON ELECTRICAL OUTLET ON STARBOARD SIDE WELDER LEAD BOX.
Condition: Unknown
Due 8 October 1998
Resolved 9 October 1998
Fire Fighting
Issued 21 September 1998 Resolved
LABEL ALL FIRE HOSE STATIONS THAT ARE NOT.
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998
Fire Fighting
Issued 9 September 1997 Resolved
HYDRO EXTINGUISHERS AS NEEDED/IDENTIFIED ON GULF WIDE SAFETY SYSTEM REPORT DATED 09SEP97.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Construction/Loadline
Issued 9 September 1997 Resolved
REPAIR OR REPLACE ALL VALVES ON BILGE MANIFOLD.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Electrical
Issued 9 September 1997 Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY GENERATOR
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
REPLACE WASTED SPOOL PIECE ON #1 FIREPUMP.
Condition: Unknown
Due 17 September 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROPERLY MOUNT FIRE ALARM PULL BOX IN SCR ROOM.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Engineering
Issued 9 September 1997 Resolved
REPLACE DAMAGED FUEL LINE ON #3 GENERATOR.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
REPAIR HEAT SENSOR BETWEEN #3 AND #4 GENERATOR.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Construction/Loadline
Issued 9 September 1997 Resolved
REPLACE GASKETS IN WTD'S BETWEEN CHANGE ROOM AND WORK SHOP, AND CHANGE ROOMAND AIR COMPRESSOR ROOM.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
REPLACE 6FT APPLICATOR IN ENGINE ROOM WITH 4FT APPLICATOR.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Electrical
Issued 9 September 1997 Resolved
REPAIR OR REPLACE ELECTRICAL BOX BELOW PHONE IN SHALE SHKER AREA.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Electrical
Issued 9 September 1997 Resolved
REPAIR OR REPLACE BROKEN OUTLETS AT DRILL FLOOR.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Lifesaving
Issued 9 September 1997 Resolved
REPAIR SHEARED LOCK BLOCK CABLE BOLTS, MAKE READY FOR INSPECTION/WEIGHT TEST, LIFEBOAT AND WINCH.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Lifesaving
Issued 9 September 1997 Resolved
REPAIR CRACKED FIBERGLASS ON TOP OF LIFEBOAT, PORTSIDE AMIDSHIPS.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Accommodation/Occupational Safety
Issued 9 September 1997 Resolved
REPLACE DATED MEDICINES IN FIRST AID KITS.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
REPLACE WASTED CO2 NOZZLE CONNECTION FOR FIXED PAINT LOCKER SYSTEM.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVIDE 1 SET OF FIREMAN'S GLOVES.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Accommodation/Occupational Safety
Issued 9 September 1997 Resolved
PROVE PROPER OPERATION OF FREEZER EMERGENCY ESCAPE KNOBS.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
LABEL FIRE DAMPNERS OPEN/CLOSED DIRECTION.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVE PROPER OPERATION OF O2/LEL PORTABLE METER
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Lifesaving
Issued 9 September 1997 Resolved
REPAIR LEAK TO FUEL INJECTOR FOR LIFEBOAT.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Lifesaving
Issued 9 September 1997 Resolved
REPAIR BRAKE RELEASE CABLE BRACKETS FOR INBOARD RAFT SO AS TO REMOVE EXCESSSLACK.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
REPLACE FRAYED PULL CABLE FOR MAIN STOP VALVE AT HALON STATION.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Electrical
Issued 9 September 1997 Resolved
REPAIR ENGINE ALARM PANEL IN ENGINE ROOM.
Condition: Unknown
Due 3 October 1997
Resolved 3 October 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVIDE INSTRUCTIONS FOR OPERATION OF HALON SYSTEM AT MAIN STATION FOR SCR/ENGINE ROOM.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
REPAIR LEAK TO NOZZLE AT FIRE STATION #8.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVIDE MOUNTS FOR FIRE EXTINGUISHERS AT STATIONS #33 AND #27.
Condition: Unknown
Due 10 October 1997
Resolved 22 September 1997
Construction/Loadline
Issued 17 April 1997 Resolved
SUBMIT REPAIR/WELDING PROCEDURES, WELDER'S QUAL'S, PLATE CERT'S, NDT REPORTS AND ABS SURVEYOR REPORTS ON LEG REPAIRS. NDT REPORTS TO INCLUDE LEGBRACING REPAIRS, ACCESS HOLES, AND THICKNESS GUAGING OF CORRODED AREAS OF LEG SHELL IN 40-80 FT ELEVATION ZONE.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Engineering
Issued 10 September 1996 Resolved
INSTALL HEAT RESISTANT (PYREX) GLASS IN EMERGENCY GENERATOR F.O. DAY TANK SIGHT GLASS.
Condition: Unknown
Due 10 October 1996
Resolved 24 October 1996
Documentation
Issued 10 September 1996 Resolved
SUBMIT TO [name withheld], A COPY OF UNDERWATER SURVEY VIDEO AND ABS/AMERICAN OIL FIELD DIVERS, INC. REPORTS.
Condition: Unknown
Due 10 October 1996
Resolved 24 October 1996
Deck/Cargo
Issued 10 September 1996 Resolved
RENEW DRILL FLOOR AIR RECEIVER IN KIND. INSURE MAWP OF NEW TANK IS EQUAL TOOR GREATER THAN ORIGINAL UNIT.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Deck/Cargo
Issued 10 September 1996 Resolved
MAKE ALL AIR RECEIVERS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 10 October 1996
Resolved 30 September 1996
Fire Fighting
Issued 10 September 1996 Resolved
RENEW SEAL IN #2 FIRE PUMP.
Condition: Unknown
Due 10 October 1996
Resolved 24 October 1996
Lifesaving
Issued 10 September 1996 Resolved
PROVIDE ON BOARD MSHA APPROVED FIRST AID KIT AS PER 33 CFR 77.1707.
Condition: Unknown
Due 10 October 1996
Resolved 24 October 1996
Fire Fighting
Issued 14 September 1995 Resolved
HYDRO TEST NITROGEN BOTTLES ON HELO DECK B-V EXTINGUISHERS.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Electrical
Issued 14 September 1995 Resolved
INSTALL GOOSENECK VENT W/ 30 X 30 IN FLAME SCREEN ON DAY TANK TO E-GEN. _x001C_
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Documentation
Issued 14 September 1995 Resolved
PROVIDE ON BOARD AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN.
Condition: Unknown
Due 14 October 1995
Resolved 29 November 1995
Fire Fighting
Issued 14 September 1995 Resolved
REPLACE FIRE APPLICATOR TIP AT F/S #2 W/ CG APPROVED TIP.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Electrical
Issued 14 September 1995 Resolved
REPAIR/REPLACE E-LIGHT PORT AFT OF MOTOR ROOM BY #4 GEN.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Lifesaving
Issued 14 September 1995 Resolved
PROVIDE ENOUGH WATER FOR LIFEBOAT CAPACITY OF 34 PERSONS (814 PACKETS).
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Lifesaving
Issued 14 September 1995 Resolved
REPAIR/REPLACE FRAYED SHIPBOARD RELEASE CABLES ON BOTH INFLATABLE LIFE RAFTS.
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Lifesaving
Issued 14 September 1995 Resolved
PROVIDE 2 ORANGE SMOKE FLOATS FOR LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1995
Resolved 28 September 1995
Lifesaving
Issued 14 September 1995 Resolved
PROVIDE APPROPRIATE OPERATING INSTRUCTIONS FOR INFLATABLE LIFE RAFT DAVIT ON VSL.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Electrical
Issued 14 September 1995 Resolved
PERFORM OVERSPEED TRIP ON EMERGENCY GENERATOR.
Condition: Unknown
Due 14 October 1995
Resolved 29 November 1995
Fire Fighting
Issued 14 September 1995 Resolved
HYDROSTATICALLY TEST PAINT LKR CO2 BOTTLE.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Fire Fighting
Issued 14 September 1995 Resolved
PERFORM HYDROSTATIC TEST ON HALON SYS FLEX LOOP HOSES.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Fire Fighting
Issued 14 September 1995 Resolved
HYDRO TEST FIRE EXT'S: 6, 13, 15, 16, 34, 40 & 44.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Fire Fighting
Issued 14 September 1995 Resolved
INSTALL SECTION OF COAST GUARD APPROVED FIRE MAIN JUMPER HOSE TO DRILL FLOOR.
Condition: Unknown
Due 14 October 1995
Resolved 26 October 1995
Fire Fighting
Issued 14 September 1995 Resolved
REPAIR/REPLACE HALON WARNING SIREN IN SCR ROOM.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Fire Fighting
Issued 14 September 1995 Resolved
PERFORM HYDROSTATIC TEST ON SCBA BOTTLE FOR FIREFIGHTING ENSEMBLE LOCATED IN HOSPITAL SPACE.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Electrical
Issued 14 September 1995 Resolved
PERFORM LOW LUBE OIL SHUTDOWN ON #2 GENERATOR.
Condition: Unknown
Due 14 October 1995
Resolved 28 September 1995
Construction/Loadline
Issued 16 September 1993 Resolved
ADJUST ALL WATERTIGHT DOORS AS NECESSARY.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Lifesaving
Issued 16 September 1993 Resolved
PROVIDE FLAME SPREAD TEST DATA OF FIBERGLASS GRATING AS PER ASTM STANDARD 84 AND A SKETCH OF ALL LOCATIONS OF THE SAME.
Condition: Unknown
Due 16 October 1993
Resolved 20 October 1993
Lifesaving
Issued 16 September 1993 Resolved
MAKE REPAIRS AND PROVE PROPER OPERATION TO LIFE BOAT WINCH AND TEST LIMIT SWITCHES.
Condition: Unknown
Due 23 September 1993
Resolved 20 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
CONDUCT UNDERWATER EXAM OF TOP, SIDES, AND BOTTOM OF MAT.
Condition: Unknown
Due 16 October 1993
Resolved 20 October 1993
Fire Fighting
Issued 16 September 1993 Resolved
REPAIR GENERAL ALARM BELLS IN FOLLOWING LOCATIONS: DRILL FLOOR, SHALE SHAKER, MUD PITS, SWITCHBOARD ROOM, HELIPORT AND TEST ON 24V SYS.
Condition: Unknown
Due 23 September 1993
Resolved 19 October 1993
Lifesaving
Issued 16 September 1993 Resolved
PROVIDE PROPERLY CHARGED AIR BOTTLES FOR LIFEBOAT ENCLOSED AIR BREATHING SYS.
Condition: Unknown
Due 23 September 1993
Resolved 19 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
MAKE REPAIRS BY INSERT TO #6 STARBOARD WING BALLAST TANK SWASH BULKHEAD.
Condition: Unknown
Due 16 October 1993
Resolved 20 October 1993
Navigation
Issued 16 September 1993 Resolved
REPLACE OBSTRUCTION LIGHT LENS ON STARBOARD BOW.
Condition: Unknown
Due 16 October 1993
Resolved 20 October 1993
Fire Fighting
Issued 16 September 1993 Resolved
REPLACE AND HYDRO TEST 2 50FT-1 1/2" FIRE HOSES FOR STATIONS #3 & 14.
Condition: Unknown
Due 23 September 1993
Resolved 20 October 1993
Lifesaving
Issued 16 September 1993 Resolved
PROVIDE ON BOARD VESSEL A CALIBRATION KIT FOR OXYGEN/LEL METER.
Condition: Unknown
Due 16 October 1993
Resolved 20 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
CROP AND RENEW MAIN DECK GOOSENECK VENTS 6PC, 6PO, 7PCL, 7PO, 6PW, 1PO, 1PW, 1PCL, 1SCL, 1SO; CLEAN AND REPAIR AS NECESSARY #3SO & CDV.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
PROVIDE CHECK VALVE (BALL) FOR #4 STBD GOOSENECK VENT.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
MAKE TEMPORARY PATCHES AS NECESSARY TO TANK VENTS IN ITEM 5 PRIOR TO FLOATING RIG.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Engineering
Issued 16 September 1993 Resolved
REPAIR LOW LUBE OIL PRESSURE SHUTDOWN ON EMERGENCY GENERATOR.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Engineering
Issued 16 September 1993 Resolved
MAKE FLEXIBLE NON-METALLIC FUEL SUPPLY AND RETURN LINES TO EMER. GEN. NO LONGER THAN 30".
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
INSTALL REINFORCEMENT COLLARS ON PIPING PENETRATIONS IN 7P BALLAST TANK.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Unknown
Issued 16 September 1993 Resolved
PROVIDE MUD PUMP PURGE AIR SUPPLY TO A NON HAZARDOUS AREA.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 16 September 1993 Resolved
REPLACE OR REPAIR WATERTIGHT DOOR FROM PORT MAIN DECK TO LAUNDRY ROOM.
Condition: Unknown
Due 16 October 1993
Resolved 19 October 1993
Electrical
Issued 30 September 1992 Resolved
PROVE THAT JUNCTION BOX ON OUTBOARD SIDE OF BLOWER MOTOR APPROVED FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Construction/Loadline
Issued 30 September 1992 Resolved
PROPERLY SEAL BULKHEAD PENETRATIONS/HOLES ON FWD BULKHEAD SHALE SHAKER AREA.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 30 September 1992 Resolved
REMOVE SPLICES AFT EDGE OF MUD PIT. REMOVE PA HORN ON MUD PIT OR REPLACE WITH ONE APPROVED FOR CLASS 1 DIV 1 AREA.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 30 September 1992 Resolved
POUR THE FOLLOWING EYS FITTINGS: 1) J-BOX NEXT TO DRILLERS CONSOLE._x001C_ 2) GENERAL ALARM BELL ON RIG FLOOR. 3) PHONE BOX NEXT TO DRILLERS CONSOLE.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 30 September 1992 Resolved
PROPERLY MOUNT EMERGENCY LIGHT ON AFT BLKHD DRILL FLOOR.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 30 September 1992 Resolved
REPLACE SPLICED WIRES IN CLASSIFIED LOCATIONS WITH APPROVED JUNCTION BOXES.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 30 September 1992 Resolved
REPLACE NON-APPROVED WIRES IN SHALE SHAKER AREA (CLASS 1, DIV 1) WITH APPROVED WIRE.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 30 September 1992 Resolved
PROVE DRAW WORKS BLOWER MOTOR APPROVED FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Electrical
Issued 17 September 1992 Resolved
INSTALL EYS FITTINGS ON TRIP TANK PUMP MOTOR.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Documentation
Issued 17 September 1992 Resolved
SUBMIT FOR APPROVAL A HAZARDOUS LOCATION PLAN WITH PLAN & ELEVATION PROFILES INDICATIONG ALL STRUCTURE IN WAY OF THE MUD PIT, SHALE SHAKER AND DRILL FLOOR AREAS PLAN SHOULD INDICATE THE HAZARDOUS AREAS IN THE WORST CASE CONDITION (I.E. WORK OVER WITH DRILL FLOOR MINIMUM SKID DISTANCE).
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Electrical
Issued 17 September 1992 Resolved
INSTALL EYS FITTINGS ON J-BOX IN SHAKER AREA ABOVE MUD SHAKER.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Electrical
Issued 17 September 1992 Resolved
STENCIL EMERGENCY LIGHTS WHERE REQUIRED.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Engineering
Issued 17 September 1992 Resolved
INSTALL HEAT RESISTANT SIGHT GLASS FOR EMERGENCY GENERATOR FUEL TANK.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Fire Fighting
Issued 17 September 1992 Resolved
PROVIDE MEANS TO CLOSE VENT IN THE PAINT LOCKER WHEN CO2 SYSTEM DISCHARGES.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
INSTALL NO-FLOW ALARM ON DRAW WORKS BLOWER SUPPLY PIPING.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Electrical
Issued 17 September 1992 Resolved
REPLACE CABLE LIGHT LEFT AND RIGHT SIDE OF DOG HOUSE. MOVE OUT OF CLASS I DIV II LOCATION BECAUSE NO APPROVAL FOR THOSE AREAS FOUND ON LIGHT.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Deck/Cargo
Issued 17 September 1992 Resolved
REWIRE ELECTRICAL CONTROLS FOR STBD SIDE HYDRAULIC CONTILEVER SKID SYSTEM. RENEW ALL DETERIORATED HYDRAULIC HOSES IN THE VICINITY.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Electrical
Issued 17 September 1992 Resolved
REMOVE SO CABLE AND INSTALL EYS FITTINGS ON EXPLOSION PROOF BOX ATTACHED TOBACK OF LIFEJACKET BOX LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Electrical
Issued 17 September 1992 Resolved
EXPLOSION PROOF BOX LOCATED IN BACK LEFT CORNER OF DRILL FLOOR.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Electrical
Issued 17 September 1992 Resolved
INSTALL PURGE AIR PRESSURE GAUGE THAT WILL INDICATE LESS THAN THREE PSI FORPURGE AIR ON MUD PUMP CONTROL BOX.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Navigation
Issued 17 September 1992 Resolved
REPLACE THE LENS IN THE PORT FORWARD OBSTRUCTION LIGHT. PROVE PROPER OPERATION OF ALL OBSTRUCTION LENS AND ENSURE THAT THEY ARE ALL LEVEL.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Electrical
Issued 17 September 1992 Resolved
FILL STUFFING TUBE OVER DOOR IN SCR ROOM.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Fire Fighting
Issued 17 September 1992 Resolved
CLEAN FIRE DAMPER SIGN OUTSIDE SCR ROOM DOOR ON RIGHT SIDE.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
REPLACE RELIEF VALVE ON AIR RECEIVER LOCATED UNDER DRILL FLOOR.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Electrical
Issued 17 September 1992 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL PRESSURE AND HIGH TEMP. ALARMS FOR EMERGENCY GENERATOR (AUDIBLE).
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
STENCIL HIGH BILGE ALARM HORN LOCATED IN CHANGE ROOM.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
PROVE PROPER OPERATION OF HIGH BILGE ALARM LOCATED BELOW FIRE STATION #3.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Unknown
Issued 17 September 1992 Resolved
PROVIDE AND POST OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.720.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Construction/Loadline
Issued 17 September 1992 Resolved
MAKE EMERGENCY ESCAPE HATCH LATCH MECHANICALLY OPERATIONAL.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
STENCIL FUEL TANKS WITH "NO BURNING, CUTTING OR WELDING".
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Electrical
Issued 17 September 1992 Resolved
INSTALL BLANK IN LP-1A ELECTRICAL BOX.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
RENEW ANGLE SUPPORTING WALK WAY TO SHAKER AREA.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
PROVIDE AN OPERATING MANUAL FOR THE LIFEBOAT. OPERATING MANUAL SHALL BE PLACED IN THE LIFEBOAT.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 17 September 1992 Resolved
PROVIDE SIX ADDITIONAL PARACHUTE FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 17 September 1992 Resolved
MAKE BOTH RING BUOYS WITH SMOKE CANISTERS ATTACH DEPLOY IN A QUICK RELEASE MANNER.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Navigation
Issued 17 September 1992 Resolved
PROVE PROPER OPERATION AND INSTALLATION OF RED MASTHEAD LIGHT.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 17 September 1992 Resolved
INSTALL PROPER SHACKLE ON THE DAVIT LAUNCHED LIFERAFT, RATED AT NOT LESS THAN TWO TONS. VESSEL MAY NOT JACK-UP ON LOCATION UNTIL THE PROPER SHACKLEIS INSTALLED AND MSO NEW ORLEANS IS NOTIFIED. NOTIFICATION MAY BE A BILL OF SALE FOR THE SHACKLE.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 17 September 1992 Resolved
PLACE APPROPRIATE MARKINGS (NO. AND CAPACITY) ON THE CONTAINER FOR THE SECOND DAVIT LAUNCHED LIFERAFT.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 17 September 1992 Resolved
REPLACE BATTERIES IN FLASHLIGHTS IN LIFEBOAT. PROVIDE SPARE BATTERIES IN LIFEBOAT.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Navigation
Issued 17 September 1992 Resolved
PROVIDE ONBOARD A DIAMOND DAY SHAPE.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Deck/Cargo
Issued 17 September 1992 Resolved
REPLACE/RENEW DECK BOLTS TO THE STBD PROPULSION UNIT.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Construction/Loadline
Issued 15 October 1991 Resolved
REPLACE BOTH 6" GATE MAIN SEA CHEST VALVES AND MAKE AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 6 November 1991
Resolved 6 November 1991
Construction/Loadline
Issued 15 October 1991 Resolved
MAKE AVAILABLE FOR VISUAL INSPECTION THE LOWER HALF OF THE MAT AND SKIRT INORDER TO COMPLETE SPECIAL EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 6 November 1991
Resolved 6 November 1991
Fire Fighting
Issued 20 September 1991 Resolved
PROVIDE ONBOARD AND POST A USCG APPROVED FIRE CONTROL AND SAFETY PLAN, INCLUDING LEGEND. INCLUDE FINAL APPROVED PLANS IN RIG OPERATIONS MANUAL.
Condition: Unknown
Due 4 October 1991
Resolved 4 October 1991
Documentation
Issued 20 September 1991 Resolved
PROVIDE ONBOARD A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Lifesaving
Issued 31 January 1991 Resolved
PROVIDE INSTALLATION OF PERSWONNEL LANDINGS IN WAY OF THE LIFEBOAT. (IN COMPLIANCE WITH MANUFACTURE'S APPROVED PLANS).
Condition: Unknown
Due 31 January 1991
Resolved 31 January 1991
Lifesaving
Issued 31 January 1991 Resolved
PROVIDE THE FOLLOWING ITEMS FOR THE #1 SURVIVAL CAPSULE: 1. 494 BAGS OF WATER (ONLY 322 ON BOARD) 2. BOARDING LADDER 3. OPERATION AND MAINTENACE MANUAL 4. EQUIPMENT LIST 5. STENCIL PORT & STBD BOW WITH RIG NAME, PORT OF REGISTRY, BOAT NUMBER, AND CAPACITY (IAW 465CFR 108.645)
Condition: Unknown
Due 31 January 1991
Resolved 31 January 1991
Fire Fighting
Issued 11 October 1990 Resolved
HYDROSTATICALLY TEST SPARE SCBA BOTTLE.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Accommodation/Occupational Safety
Issued 11 October 1990 Resolved
REPAIR OR REPLACE RELIEF VALVES ON RIG AIR AND START AIR RECEIVERS AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Electrical
Issued 11 October 1990 Resolved
DEMONSTRATE #4 DIESEL GENERATOR LOW LUBE OIS SHUTDOWN TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Engineering
Issued 11 October 1990 Resolved
DEMONSTRATE PROPER OPERATION OF LOW SUCTION FUEL SHUTOFF VALVE.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Construction/Loadline
Issued 11 October 1990 Resolved
RESTAFF BULKHEAD PENETRATION BETWEEN ENGINEROOM AND HYDRAULIC ROOM.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Lifesaving
Issued 11 October 1990 Resolved
CONDUCT A WEIGHT TEST OF DAVIT LAUNCHED LIFERAFT SYSTEM AS PER 46 CFR 107.239 IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Documentation
Issued 11 October 1989 Resolved
PROVIDE AND POST OIL TRANSFER PROCEDURES AS REQUIED BY 33CFR155.720 . (ENSURE PERSON IN CHARGE HAS TANKERMAN'S CERTIFICATE OR EQUIVALENT.)
Condition: Unknown
Due 11 October 1989
Resolved 11 October 1989
Deck/Cargo
Issued 11 October 1989 Resolved
CONDUCT TEST OF ONE & A HALF MAWP ON EACH FUEL/OIL SERVICE HOSE; MARK HOSES "OIL SERVICE", DATE OF LAST TEST, AND MAXIMUM ALLOWABLE WORKING PRESSURE (MAWP). REF: 33 CFR 156.170(F)
Condition: Unknown
Due 11 October 1989
Resolved 11 October 1989
Lifesaving
Issued 11 October 1989 Resolved
RELOCATE PORT & STARBOARD QUICK-RELEASE LIFE RING BUOYS WITH SMOKE FLARES TO OUTBOARD OF HAND RAIL, SO AS TO FALL TO SEA WHEN RELEASED.
Condition: Unknown
Due 11 October 1989
Resolved 11 October 1989
Lifesaving
Issued 11 October 1989 Resolved
REPLACE OR REPAIR DETERIORATED ESCAPE ROPE FOR LIFE FLOAT EMBARKATION, PORT SIDE.
Condition: Unknown
Due 11 October 1989
Resolved 11 October 1989
Lifesaving
Issued 23 May 1988 Resolved
REPLACE FADED RING LIFE BOUYS WITH NEW "INTERNATIONAL ORANGE" RING LIFE BOUYS AND PROPERLY MARK WITH VESSEL NAME AND HOMEPORT.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Fire Fighting
Issued 23 May 1988 Resolved
PROVIDE EVIDENCE THAT THE UNMARKED "RED HOSE" ATTACHED TO THE SEMI-PORTABLEFIRE EXTINGUISHER ON THE HELO DECK IS APPROVED AND SUITABLE FOR HIGH PRESSURE SERVICE OR REPLACE WITH APPROVED HOSE.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Fire Fighting
Issued 23 May 1988 Resolved
REPLACE RECALLED ANSUL EX607 HOSE (1480-2Q81) FOR THE SEMI-PORTABLE FIRE EXTINGUISHER ON HELO DECK.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Construction/Loadline
Issued 15 October 1987 Resolved
APPROPRIATELY LABEL PUMP CONTROLLERS AND BILGE/BALLAST VALVES.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Lifesaving
Issued 15 October 1987 Resolved
LABEL ALL GENERAL ALARM BELLS AND LIGHTS WITH REQUIRED MARKING IN ACCORDANCWITH 46 CFR 97.37.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Fire Fighting
Issued 15 October 1987 Resolved
REPAIR OR REPLACE BROKEN NOZZEL TIP RETAINING CHAINS ON COMBINATION NOZZELS
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Electrical
Issued 15 October 1987 Resolved
PROVIDE CORROSION RESISTANT LINING FOR SCR BATTERY BOX AT LEAST TO A HEIGHTOF 3 INCHES, WHICH IS WATER TIGHT.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Electrical
Issued 15 October 1987 Resolved
REPAIR BATTERY BOXES FOR OBSTRUCTION LIGHT&GENERAL ALARM SO AS TO BE WATER TIGHT TO A HEIGHT OF AT LEAST 3 INCHES AND PROPERLY SECURE CONTAINER LIDS.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Fire Fighting
Issued 15 October 1987 Resolved
PROVIDE EVIDENCE OF HYDROSTATIC TESTING FOR CO2 STEEL FIRE EXTINGUISHERS ATSTATIONS 19 AND 20.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Electrical
Issued 15 October 1987 Resolved
INSTALL GUARDS ON EMERGENCY GENERATOR FUEL TANK SIGHT GUAGE.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Lifesaving
Issued 15 October 1987 Resolved
SUBMITT PLANS FOR THE INSTALLATION OF ADDITONAL LIFESAVING EQUIPMENT, ALONGWITH A REVISED LIFESAVING PLAN, TO THE OCS SECTION AT THE ABOVE ADDRESS, FOR APPROVAL OF THE SAME.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Deck/Cargo
Issued 15 October 1987 Resolved
REMOVE RUBBER HOSE AND INSTALL APPROPIATE VALVES, FITTINGS AND PIPING FOR CLASS II SERVICE ON DISCHARGE LINE OF DERRICK AIR RECEIVER IN ACCORDANCE WITH 46CFR PART 56.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Accommodation/Occupational Safety
Issued 15 October 1987 Resolved
PROVIDE EVIDENCE DEMONSTRATING THE RELIEF VLAVE ON THE AIR CUSHIONED SANITARY WATER SUPPLY TANK IS SET A 100 PSIG OR LESS, OR OPEN THE TANK FOR INTERNAL INSPECTION.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Construction/Loadline
Issued 23 April 1987 Resolved
MAKE RIG AVAILABLE FOR DRYDOCK EXAMINATION BY A MARINE INSPECTOR PRIOR TO PLACING RIG IN SERVICE, BUT IN NO CASE LATER THAN 14OCT88.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Navigation
Issued 2 December 1985 Resolved
PROVIDE A DIAMOND DAY SHAPE, REF COLREGS AND 33 CFR 67.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Electrical
Issued 2 December 1985 Resolved
FREE UP AND LABEL REMOTE FUEL SHUTOFF EMERGENCY GENERATOR.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE RESCUE BOAT: TWO (2) FLASHLIGHTS, TOWLINE REPAIR KIT, AND TOWING BRIDLE. PER 46 CFR 94.10-5 AND [name withheld]8 LTR DTD 22JAN81.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Fire Fighting
Issued 2 December 1985 Resolved
PROVIDE ADDITIONAL B-V FIRE EXTINGUISHER FOR THE HELO DECK. REF 46 CFR 95.50-10A.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Fire Fighting
Issued 2 December 1985 Resolved
PROVIDE SPARE CHARGES FOR BOTH SELF CONTAINED BREATHING APPARATUS. REF 46 CFR 96.35-20.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Navigation
Issued 2 December 1985 Resolved
PROVIDE WIND SOCK FOR HELO DECK. REF 46 CFR 108.653
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Electrical
Issued 2 December 1985 Resolved
REPAIR INOPERATIVE GENERAL ALARM BELLS IN HYDROLIC AND AIR COMPRESSOR ROOMSREF 46 CFR 97.37-7.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Electrical
Issued 2 December 1985 Resolved
PROPERLY LABEL GENERAL ALARM BELLS, HELO DECK. REF 46 CFR 97.37-7.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Electrical
Issued 2 December 1985 Resolved
REMOVE REUSABLE FUSE FOR FOG HORN, BATTERY BANK. REF 46 CFR 111.30.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Electrical
Issued 2 December 1985 Resolved
PROVIDE RUBBER MAT IN SCREEN ROOM FOR SWITCHBOARDS. REF 46 CFR 111.30.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Deck/Cargo
Issued 2 December 1985 Resolved
PROVIDE HAND SIGNAL CHART IN CRANE. REF CFR 91.37-45.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Deck/Cargo
Issued 2 December 1985 Resolved
TEST FUEL LOAD HOSE. REF 33 CFR 155.80.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROPERLY STENCIL THE LIFEFLOAT MOUNTED ON THE PORT BOW. REF 46 CFR 94.05-5.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE DOCUMENTATION THAT THE RESCUE BOAT ONBOARD IS APPROVED. REF 46 CFR 94.05-1.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE ONBOARD TWELVE (12) HANDHELD ROCKET PROPELLED PARACHUTE RED FLARE DISTRESS SIGNALS. REF 46 CFR 94.90-5.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE ILLUMINATION AT LIFERAFT STATION DAVIT LAUNCH DOWN TO THE WATER. REF 46 CFR 111.75-15(E).
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Accommodation/Occupational Safety
Issued 2 December 1985 Resolved
REPAIR OR REPLACE THE VENT CLOSURES ON THE MAIN DECK WHERE DETERIORATED ANDREPAIR STUDS ON MANHOLE COVER TO SLOP TANKS. REF 46 CFR 92.15-10.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE TWO MEANS OF ESCAPE FROM PIPE RACK DECK. REF 46 CFR 92.10-5.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Deck/Cargo
Issued 2 December 1985 Resolved
INSTALL GUARD ON AIR-TUGGERS LOCATED AT STERN MAIN DECK. REF 46 CFR 92.25-15.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Fire Fighting
Issued 2 December 1985 Resolved
SUBMIT FOR APPROVAL, THE FIRE CONTROL PLAN AND THE HAZARDOUS LOCATION PLAN REF 46 CFR 91-55-5.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Fire Fighting
Issued 2 December 1985 Resolved
PROVIDE FIRE HOSE AT STATION #5. FAILED DURING HYDRO. REF 46 CFR 95.10-1.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Engineering
Issued 2 December 1985 Resolved
LABEL REMOTE SHUTOFF SWITCHES FOR ALL FUEL OIL TRANSFER PUMPS. REF 46 CFR 56.50-75.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE TEST DATA ON DAVIT LAUNCH HOOK/RELEASE.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE TEST DATA FOR LINE THROWING APPARATUS. REF 46 CFR 97.15-25.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Lifesaving
Issued 2 December 1985 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE LINE THROWING APPARATUS: ONE (1) SVC LINE, FOUR (4) PRIMER CARTRIDGES, (FOUR (4) ROCKET, TWO (2) FLOAT TYPE). REF 46 CFR 94.45-15.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Accommodation/Occupational Safety
Issued 2 December 1985 Resolved
REPAIR VENTILATION CIRCUT BREAKER, MCC "B" (ACCOMODATION SPACE). REF 46 CFR 111.103.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Fire Fighting
Issued 2 December 1985 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE FIREMAN'S OUTFIT: FLASHLIGHTS, GLOVES, AND FLAME SAFETY LAMP. REF 46 CFR 96.35-10.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Accommodation/Occupational Safety
Issued 2 December 1985 Resolved
PROVE SATISFACTORY OPERATION OF THE QUARTER VENTILATION SHUTDOWN. REF 46 CFR 111.103.
Condition: Unknown
Due 2 December 1985
Resolved 2 December 1985
Unknown
Issued 13 September 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE M/V DOLPHIN TITAN RIG 105, O.N. 653832. THE BELOW LISTED ITEM IS TO BE COMPLIED WITH BY 13OCT84.
Condition: Unknown
Due 13 September 1984
Resolved 13 September 1984
Construction/Loadline
Issued 13 September 1984 Resolved
PROVIDE APPROVED PLAN SHOWING MODIFICATION TO UPPER HULL WITH DEEP WELL REMOVED.
Condition: Unknown
Due 13 September 1984
Resolved 13 September 1984
Electrical
Issued 31 December 1982 Resolved
ALL GENERAL ALARM CONTACT MAKERS EXCEPT IN TOOL PUSHERS OFFICE SHALL BE PROTECTED BY AN ENCLOSURE WITH BREAKABLE TRANSPARENT WINDOW:
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
(REQ. 9 CONTINUED) 46 CFR 113.25-5(A).
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Engineering
Issued 31 December 1982 Resolved
RE-ROUTE AIR LINE SO AS TO AVOID TRANSITING THROUGH THE LUBE OIL TANK.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Construction/Loadline
Issued 31 December 1982 Resolved
INSTALL VALVE IN EACH OF THE TWO AIR LINES LEADING TO THE SEA CHEST AT THE SEA CHEST.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Construction/Loadline
Issued 31 December 1982 Resolved
REPAIR THE DAMAGED SAFETY NETTING AROUND THE HELIPORT.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Accommodation/Occupational Safety
Issued 31 December 1982 Resolved
PROVIDE DIVIDERS FOR TOILETS IN THE CHANGE ROOM.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
AIR RECEIVER TO BE INSTALLED ON THE DRILL FLOOR REQUIRES TEST OF RELIEF VALVE.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Navigation
Issued 31 December 1982 Resolved
INSTALL OBSTRUCTION LIGHTS IN ACCORDANCE WITH 46 CFR 143.15(A) AND DEMONSTRATE OPERATION TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DOLPHIN TITAN RIG 1O5, DN653832.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Electrical
Issued 31 December 1982 Resolved
VERTICAL ELECTRIC CABLE RUNS MUST BE INDIVIDUALLY BANDED BY COMMON SIZE TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 1 March 1983
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
COMPLETE MARKING AND LABELING OF VESSEL.
Condition: Unknown
Due 1 March 1983
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
PERMANENTLY INSTALL REQUIRED PLACARDS AND WARING SIGNS.
Condition: Unknown
Due 1 March 1983
Resolved 31 December 1982
Electrical
Issued 31 December 1982 Resolved
PROVIDE ACCESS TO MAIN GENERATOR FUEL SHUT OFF VALVES WHERE FLEXIBLE NON- METALIC HOSES ARE CONNECTED.
Condition: Unknown
Due 1 March 1983
Resolved 31 December 1982
Fire Fighting
Issued 31 December 1982 Resolved
ELECTRICAL CABLE FOR THE NUMBER 2 FIRE/BALLAST PUMP SHALL BE RUN SO AS TO AVOID PENETRATING THE BOUNDARIES OF THE MACHINERY SPACE IN ACCORDANCE
Condition: Unknown
Due 1 March 1983
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
(REQ. 6 CONTIUED) WITH: 46 CFR 112.05-5.
Condition: Unknown
Due 1 March 1983
Resolved 31 December 1982
Accommodation/Occupational Safety
Issued 31 December 1982 Resolved
FIRE DAMPER RELEASE CABLES FOR DAMPERS IN SCR ROOM VENTILATION SYSTEM SHALLBE RUN TO PROVIDE FOR CLOSING OF THE FIRE DAMPERS FROM OUTSIDE SCR ROOM.
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Accommodation/Occupational Safety
Issued 31 December 1982 Resolved
NON RETURN STOP VALVES SHALL BE INSTALLED IN THE BILGE MANIFOLD FOR THOSE BILGE SUCTION LINES NOT PROVIDED WITH A CHECK VALVE AT OR NEAR THE SUCTION
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982
Unknown
Issued 31 December 1982 Resolved
(REQ. 8 CONTINUED) END IN ACCORDANCE WITH: 46 CFR 56.50-50(3)(C)(1)
Condition: Unknown
Due 31 December 1982
Resolved 31 December 1982

Casualty record · 3

1 August 2000Major Marine Casualty · role: Involved in a Marine Casualty · 2 injured · activity 7175
16 October 2001Routine · role: Involved in a Marine Casualty · activity 163456
3 October 2002Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1685875
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.