MAURY USCG vessel records Sign in
← All vessels

KELLY MORRISON

KELLY MORRISON is a 1983 industrial vessel. The Coast Guard has recorded 88 inspections since 1983, most recently in December 2025, along with 89 deficiencies, 1 operational control and 3 casualty investigations between 2007 and 2016.

Records from 1983 to 2025. Most recent: inspection, 9 December 2025.

Built
1983
Last inspected
9 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8216485 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC7532
Flag
UNITED STATES
367072840
Maury page id
psix-54884

Inspections, by type

…with no type recorded25
Years with a record 36 calendar years (1983–2025)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)166.1 ft × 40.0 ft × 14.0 ft
Registered tonnagegross 298 / net 202
ITC dimensions (L × B × D)166.1 ft × 40.0 ft × 14.0 ft
ITC tonnagegross 750 / net 225
BuilderMCDERMOTT INCORPORATED · NEW IBERIA, LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 September 2025 · expires 30 September 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it750 - Convention (Subpart B), Gross Ton
298 - Regulatory (Subpart C or D), Gross Ton
225 - Convention (Subpart B), Net Ton
202 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7532MMSI 367072840 · active · compulsorily equipped · granted 9 December 2025, expires 21 October 2035
WRB9569MMSI not assigned · expired · compulsorily equipped · granted 9 December 1997, cancelled 3 May 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GO PATRIOT Offshore Supply Vessel · MISLE 664008 · 30 August 2016 · activity 5996679POOL RIG 50 Mobile Offshore Drilling Unit · MISLE 320584 · 29 June 1999 · activity 78481

Inspection history · 88

9 December 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8270298
3 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8262548
5 February 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8074959
17 April 2024 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7892028
29 March 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7887088
27 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7642405
30 July 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7546383
6 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7425793
8 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7392434
18 November 2020 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7098007
14 October 2020 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7089581
13 October 2020 Appeal
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 7076369
6 January 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6883764
28 November 2018 Hull Examination · Annual Survey · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6588425
29 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6345845
7 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6100380
27 February 2017 Examination of Repairs · Commercial Dive Inspection · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6095452
30 August 2016 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5996679
30 November 2015 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5771964
13 November 2015 Deficiency Check · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5763096
11 January 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4222367
9 November 2010 Internal Structural Exam · Hull Examination · COI Inspection · Drydock Exam · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3888347
3 February 2010 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3674385
27 January 2009 Commercial Dive Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3401373
4 December 2008 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3374086
16 October 2008 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3367131
12 February 2008 Commercial Dive Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3146472
27 July 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3009201
17 June 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2992372
30 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2946260
25 April 2007 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2946323
17 April 2007 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2909561
17 April 2007 Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2909579
10 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2675669
12 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2623227
18 October 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2517090
26 September 2005 Deadweight Survey · Hull Examination · MTSA Verification · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501146
8 February 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1485149
4 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059923
15 February 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471597
6 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 157987
17 April 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817043
13 March 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 816360
11 January 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756989
7 January 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 195421
18 November 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 526007
29 June 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 78481
4 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793225
30 April 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792852
21 September 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 800862
15 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473188
27 March 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455572
30 July 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116546
19 June 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438602
29 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 539808
26 April 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 42648
31 January 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 135657
20 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454344
11 June 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371433
26 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 656434
26 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 701500
24 January 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380405
20 June 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412824
8 November 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172416
22 September 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1181344
18 August 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407364
16 October 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 113024
28 June 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440713
16 February 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405373
13 August 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362642
30 June 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407078
26 June 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923461
23 January 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912840
20 July 1990 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918000
25 July 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1034081
27 June 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208280
27 December 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198213
13 July 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036164
11 March 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337049
8 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336803
29 January 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1325225
15 November 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319714
7 July 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028793
10 July 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292741
16 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292471
20 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286551
14 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974635
5 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973807

Deficiency record · 89

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2025 Resolved
Inspection shall insure that the vessels machinery is in satisfactory condition. The stbd main diesel engine has a substantial exhaust leak in the engine room. Find leak and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2025
Resolution: Flex pipe about 6 feet up the stack was cracked, replaced flex pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2025 Resolved
Inspection shall insure that the vessels machinery is in satisfactory condition. The port main diesel engine would not start.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2025
Resolution: Starter replaced, port main started.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2025 Resolved
Inspection shall insure that the vessels machinery is in satisfactory condition. The stbd ship's service generator would not shutoff when testing the overspeed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2025
Resolution: Fuel shutoff solenoid replaced, generator shutdown completely on overspeed test.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 December 2025 Resolved
Vessels shall have efficient guard rails as least two courses high. The elevated platform in front of the crane was missing the bottom chain.
Action required: 10 - Deficiency Rectified
Resolved 9 December 2025
Resolution: Chain replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2025 Resolved
Each crane must be inspected IAW A.P.I. RP 2D, Recommended Practice and Maint. of Offshore cranes. The angle indicator on the boom was missing the indications for the angle; fix prior to crane use
Action required: 10 - Deficiency Rectified
Resolved 9 December 2025
Resolution: New angle indicator installed.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 February 2025 Resolved
A vessel engaged in commercial service shall maintain a video survellance system with overnight accomodations for 10 or more people. Vessel does not have survellance system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2025
Resolved 7 March 2025
Resolution: Received proof of installation & full operation of surveillance equipment.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 17 April 2024 Resolved
A designated duty engineer may serve as chief engineer provided the person holds the appropriate STCW endorsement; chief engineer did not have C/E STCW endorsement. 46 CFR 15.915
Action required: 10 - Deficiency Rectified
Resolved 17 April 2024
Resolution: C/E with appropriate STCW endorsement brought on board during inspection.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 17 April 2024 Resolved
Where installed, fire detecting systems shall meet applicable installation requirements; portable accommodation module was missing one smoke detector. 46 CFR 95.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 18 April 2024
Resolution: PAM smoke detector installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2024 Resolved
Electrical system installations are to meet subchapter J requirements; improperly sized breaker installed in pilothouse. 46 CFR 91.25-30 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 18 April 2024
Resolution: Breaker replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2024 Resolved
Electrical system installations are to meet subchapter J requirements; electrical cables found to be insufficiently supported, and junction box on the fly bridge was not properly secured. 46 CFR 91.25-30 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 18 April 2024
Resolution: Cables supported by metal supports and junction box permanently affixed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 April 2024 Resolved
Electrical system installations are to meet subchapter J requirements; one (01) e-light found to be inoperable in the port side E/R. 46 CFR 91.25-30 (Old "I")
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 18 April 2024
Resolution: E-light fixed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 April 2024 Resolved
Each crane must be inspected in accordance with Section 3 of the API Recommended Practice for Operation and Maintenance of Offshore Cranes; boom angle indicator was not present due to blasting and painting the crane. 46 CFR 107.259
Action required: 10 - Deficiency Rectified
Resolved 17 April 2024
Resolution: Boom angle indicator re-installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 February 2023 Resolved
Falls used in a launching appliance must be replaced at intervals not more than 4 years. Falls were renewed in 2018 and not end for ended at 30 months.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2023
Resolved 28 February 2023
Resolution: Vessel provided tech report from 3rd party attesting to replacement of wire rope and weight test of rescue boat davit.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 February 2023 Resolved
All machinery capable of injuring personnel shall be provided with guards. Guards around shafts do not offer adequate protection.
Action required: 705 - Other - as specified
Due 30 November 2023
Resolved 18 April 2024
Resolution: Guards satisfactory
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2022 Resolved
Galley uptakes and similar sources of ignition shall be kept clear of and suitably insulated from any woodwork or combustible matter. Frying vat in the galley is located beneath a wooden cabinet with no ventilation or fire protection, must be reconfigured accordingly.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 16 March 2022
Resolution: Provided photographic evidence of galley protection
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 February 2022 Resolved
In the event of alterations involving the safety of vessel, the applicable plans shall be submitted for approval. PAM installation did not have installed PA and approved plans for PAM. Must have installed PA and approved plans from MSC for PAM.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 8 March 2022
Resolution: Sumbitted plans for PAM replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022 Resolved
Non-conducting mats or gratings must be suitable for the specific switchboard voltage installed for personnel protection at the front and rear of the switchboard. Approved type II matting must be in front of the switchboard in engine room.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 8 March 2022
Resolution: Provided photographic evidence of mat in front of switchboard.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 8 February 2022 Resolved
All crew spaces are to be constructed and arranged in a manner suitable to the purpose of which they are intended. Missing door handle on PAM. Replace handle.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 15 March 2022
Resolution: Vsl rep provided pictures of replaced door handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020 Resolved
FUEL LINES MUST BE SEAMLESS STEEL, ANNEALED SEAMLESS COPPER OR BRASS PIPE OR TUBING, OR OF NICKEL COPPER OR COPPER NICKEL COPPER OR COPPER NICKEL ALLOY. VSL HAS BROKEN F/O RETURN LINE IN THE ENGINE ROOM WHICH ARE BROKEN AND HAVE BEEN REPLACED BY A LONG LENGTH OF NON-METALLIC PIPING. IN ADDITION THERE ARE MULTIPLE PARTS OF THE F/O SYSTEM IN THE ENGINE ROOM THAT APPEAR TO BE WASTED BEYOND 25% THESE AREAS MUST BE CROPPED AND RENEWED WITH APPROVED PIPING. 46 CFR 56.50-75
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2020
Resolution: Attended vsl and inspected the installation of new F/O return piping and F/O supply lines to the F/O purifier. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2020 Resolved
02 hoses on the port and 02 hoses on the starboard MDE's. Vessel must ensure the hoses and fittings meet SAE J1942 & SAE J1475 respectively. Also, 01 fuel hose was deteriorated on generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2020
Resolution: Replaced hoses and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2020 Resolved
The vessel E-stop on the stbd MDE was not functional upon arrival. Repair and test E-stop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2020
Resolution: Replaced solenoid and tested sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2020 Resolved
Vessel has plastic fuel filter bowls on multiple engineering systems to include; Generators and MDE's. Vessel must meet CG approved standard of fuel filter bowls meeting ASTM F 1201.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2020
Resolution: Replaced all fuel filter bowls.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 7 January 2020 Resolved
Fuel transfer procedures must be permanently posted or available at a place where the procedures can be easily seen near the transfer station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 January 2020
Resolution: Posted x-fer procedures.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 January 2018 Resolved
Repair extinguished Nav light (FWD anchor)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 3 April 2018
Resolution: Repaired to the satisfaction of marine inspector
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 January 2018 Resolved
Adjust all watertight doors to ensure proper closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 3 April 2018
Resolution: All doors were adjusted.
Engineering › Fuel Oil Service System › Hose
Issued 29 January 2018 Resolved
Replace fuel oil/ oil hoses on the following machinery; Port SSDG- oil gauge hose, jet pump engine-fuel oil supply, Central SSDG- Return fuel line, Port MDE- fuel return, Rescue Boat Davit-3 hydraulic lines, Deck Jet Pump engine-Fuel and oil hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 3 April 2018
Resolution: All improper hoses were replaced.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 29 January 2018 Resolved
Remove storage bin, restricting access to STBD embarkation station.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 3 April 2018
Resolution: Storage bin was relocated and embarkation route was cleared.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 January 2018 Resolved
Port watertight door to engine room gasket channel near bottom is wasted. Repair to original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 3 April 2018
Resolution: Watertight door was repaired.
Communications › Alarms/Indicators › Fire Alarm
Issued 29 January 2018 Resolved
Engine room fire alarm beacon light is weak and inconsistent. repair to original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 3 April 2018
Resolution: Fire alarm beacon light was repaired.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 1 March 2017 Resolved
Requested approved copy of automation test procedures.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 April 2018
Resolution: Vessel rep updated the automation test procedures and were approved by MSU Houma.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 1 March 2017 Resolved
Emergency steering showed 8 degrees to port while bridge readings were at zero.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 30 March 2017
Resolution: installed correct life buoys and smokes
Lifesaving › Buoyant Smoke Signals › General
Issued 1 March 2017 Resolved
02 life buoys needed with smoke signals on bridge. Only one smoke signal was provided with the wrong ring buoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 30 March 2017
Resolution: installed correct life buoys and smokes
Lifesaving › Launching Appliances › Lines
Issued 1 March 2017 Resolved
Rescue boat davit cable was rusty and needed replacement or lubrication and testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 29 January 2018
Resolution: Rescue boat davit wire rope was in satisfactory condition for attending Coast Guard marine inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 February 2017 Resolved
02 life jackets in engine room considerably covered in grease/soot and require replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 March 2017
Resolution: Replaced with 02 new life jackets. 02 defective life jackets were destroyed and removed from service.
Fire Fighting › Fire Main › Condition
Issued 27 February 2017 Resolved
Ballast piping to fire manifold that ties into fire main is currently being repaired. Approximately 4 foot section cut out.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2017
Resolution: Repaired and replaced piping. Hydrostatically tested to 1.5 MAWP; 85psi. Test satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2017 Resolved
Lighting fixture on 02 deck in main passageway is being utilized as a junction box for an outlet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 March 2017
Resolution: Cable removed from lighting fixture and outlet removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 27 February 2017 Resolved
Jacket water temperature sensor on stbd main was not secure. Attached by cable with a ziptie.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 3 March 2017
Resolution: Secured sensor to metal plate with bolts.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 30 November 2015 Resolved
International Loadline Certificate expired Vessel was recently on drydock, however did not complete the required items to obtain a new Int. Loadline Cert from ABS. Met with ABS and vessel representative, the outstanding items are being addressed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: New Loadline issued by ABS.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 November 2015 Resolved
Jet pump in engine room missing guard around shaft and exhaust lagging.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Guard and lagging installed.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 30 November 2015 Resolved
Upon arrival it was identified that the STBD forward generator was having automation issues. The overspeed device was inoperable. Prove proper operation of shutdowns on engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Ran engine and tested shutdowns.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 30 November 2015 Resolved
Safety radio certificate and FCC authorization expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 2 December 2015
Resolution: Certificates renewed
Engineering › Fuel Oil Service System › Valve, Solenoid
Issued 30 November 2015 Resolved
Prove proper operation of emergency fuel shutdowns. 1)Port Day Tank 2)#2 storage tank port 3)#2 storage tank STBD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Tested remote valves.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 30 November 2015 Resolved
Have 5 year crane weight test witnessed by USCG, ABS or ICGB as required by 46 CFR 107.257. Vessel rep discussed conducting weight test at next annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 7 March 2017
Resolution: Witnessed 5 year crane weight test conducted by Southern Hydraulic and Crane. All Sat
Construction/Loadline › Structures › Door
Issued 30 November 2015 Resolved
Multiple WTD's and hatches would not seal. Service WTD's and hatches, prove proper operation of all WTD'd and hatches.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 3 December 2015
Resolution: Verified WTD's operational
Engineering › Lubricating Oil Service System › Piping
Issued 30 November 2015 Resolved
Replace leaky and wasted flexable hoses, piping and chain guard on Port winch on deck. Replace outboard walkway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Walkway removed and hoses piping renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 November 2015 Resolved
Renew cracked J-box and light fixture on port winch inboard side.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: J-box and fixture replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 November 2015 Resolved
Replace missing exhaust lagging on port generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Lagging replaced
Electrical › Electric Supply System (service) › Cable
Issued 30 November 2015 Resolved
Attach wire support rack which is hanging above the port generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Support rack reattached
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 30 November 2015 Resolved
Remove automatic sub pumps which are installed in bilge under jet pump which has oily water present. Prove that jet pump does not have excessive leakage.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Sub pumps removed and jet pump ran.
Electrical › Electric Supply System (service) › Cable
Issued 30 November 2015 Resolved
Temporary wire used as permanent for submersible pump in the passage way. Remove and explain why a automatic pump is needed in the space.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 2 December 2015
Resolution: Sub pump and ext cord removed
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 30 November 2015 Resolved
Non Tank vessel response plan approval letter not avalible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Resolution: Went to Homeport while on the vessel, printed and placed in binder.
Lifesaving › Inflatable Liferafts › Float Free
Issued 30 November 2015 Resolved
Liferaft rack had pins painted preventing proper operation. Chains were also missing which would allow the rack to fall to the main deck not directing to the water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2015
Resolved 30 November 2015
Resolution: Pins freed and chains replaced allowing the rafts to be manually released directly overboard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 November 2015 Resolved
Power strips were used on the bridge for high draw equipment- refrigerator and coffee pot. install receptacles in required locations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Resolution: Equipment relocated near the installed receptacles.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 January 2012 Resolved
Provide manning for vessel as indicated on Temporary COI issued on 11 Jan 2012, prior to 30 days from this date.
Action required: 705 - Other - as specified
Due 11 February 2012
Resolved 11 January 2012
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 February 2010 Resolved
Renew alcohol test strips onboard vsl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 February 2010 Resolved
Submit updated fir & safety plan for aproval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Communications › Internal Communications System › Sound-powered Telephone
Issued 3 February 2010 Resolved
Re-install missing dial selector on SPT in rudder room alleyway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 January 2009 Resolved
Tides, Currents and Coast pilot were from previous year. Update publications.
Due 27 February 2009
Resolved 3 February 2010
Engineering › Lubricating Oil Service System › Gauge
Issued 27 January 2009 Resolved
Transmisssion guages in pilothouse were reading eroneous readings. The forward guage for the starbord engine and the aft guage for the port engine.
Due 27 February 2009
Resolved 3 February 2010
Stability › Watertight Integrity › General
Issued 18 December 2007 Resolved
PVC piping through watertight bulkhead does not have metallic valves. PVC piping through a watertight bulkhead shall have metalic valves on both sides or one side with remote operation.
Due 25 December 2007
Resolved 19 December 2007
Resolution: Valves installed correctly.
Lifesaving › Launching Appliances › Falls
Issued 30 May 2007 Resolved
Vessel is required to install, test and demonstrate operation of a CG Approved powered, dedicated rescue boat davit to cognizant OCMI by 23 March 2008. All stability impact must also be mitigated prior to installation and final CG Approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 3 February 2010
Resolution: Vessel installed and tested approved rescue boat davit IAW approved plans. All sat.
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 17 April 2007 Resolved
Port main engine gear box housing sustained a fracture along the forward housing case. Coupling on the aft section of the housing was also damaged after the grounding incident. Make permanent repairs to the port main engine gear box and shaft and prove proper operation of the port main engine to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 29 May 2007
Resolution: Shaft was replaced.
Engineering › Steering Gear System › Rudder
Issued 17 April 2007 Resolved
Vessel grounded in Matagorda Bay resulting in the loss of the port side rudder. Vessel is required to replace port side rudder and ensure proper operation to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 29 May 2007
Resolution: Rudder was replaced and tested while tied up and underway.
Engineering › Steering Gear System › Rudder Stock
Issued 17 April 2007 Resolved
The vessel grounded in Matagorda Bay resulting in the starboard side rudder stock being bent. Vessel is required to renew and repair the starboard side rudder post and prove proper operation of the steering system to the satisfaction of an attending Coast Guard Marine Inspector
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 29 May 2007
Resolution: Rudder replaced, tested pier side and underway...
Engineering › Steering Gear System › Ram
Issued 17 April 2007 Resolved
The starboard side hydraulic ram on the vessels steering gear system was sheered off at the foundation plate on the bulk head. Vessel is required to repair and renew the starboard side steering ram and prove proper operation of the steering system to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 29 May 2007
Resolution: Plate rebuilt and ram was reattached, system tested.
Construction/Loadline › Hull › Side Shell
Issued 17 April 2007 Resolved
Coast Guard inpsector was unable to enter the aft peak tanks to determine the extent of damage sustained to the stern shell plating and framing . When vessel is hauled out for repairs, aft peak tanks to be certified safe by a Marine Chemist and complete damage assessment to be carried out by attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 29 May 2007
Deck/Cargo
Issued 19 June 1997 Resolved
PLACE STARBOARD ANCHOR ONBOARD AND PROVE PROPER OPERATION OF WINDLASS/GEAR.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Engineering
Issued 11 June 1996 Resolved
PROVE OPERATION OF CONTROL AIR RECEIVER PRESSURE REGULATOR PROIR TO OPERATION OF VESSEL.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 11 June 1996 Resolved
REPLACE DEFECTIVE CONTROL AIR RECEIVER RELIEF VALVE. MUST BE SET BELOW _x001C_ 165 PSI.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Lifesaving
Issued 11 June 1996 Resolved
REPLACE RING BOUY LINES AND WATER LIGHT LINES TO PORT BRIDGE WING AND PORT MAIN DECK RING BOUYS.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Navigation
Issued 11 June 1996 Resolved
PROVIDE CHARTS NO.S 11361, 11364, AND 11368 (UP TO DATE).
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 11 June 1996 Resolved
PROVE OPERATION OF OILY WATER SEPARATOR (OR REMOVE EQUIPMENT FROM VESSEL).
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Documentation
Issued 18 August 1994 Resolved
SUBMIT FOR REVIEW DOCUMENTARY EVIDENCE AND/OR CALCULATIONS SHWOING THAT EQUIPMENT INSTALLED ON CARGO DECK IS WITHIN CONSTRAINTS/ALLOWANCES OF STABILITY BOOKLET.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Engineering
Issued 18 August 1994 Resolved
HYDROSTATICALLY TEST IN THE PRESENCE OF A MARINE INSPECTOR THE SEA WATER SUCTIONLINE FROM ENGINE ROOM TO ON DECK CARGO PUMP ENGINES.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Documentation
Issued 18 August 1994 Resolved
SUBMIT TO THIS OFFICE FOR REVIEW AND APPROVAL, A REVISED FIRE AND SAFETY PLAN SHOWING THE ADDITIONAL SEMI-PORTABLE FIRE EXTINGUISHERS, PORTABLE FOAMUNIT AND EMERGENCY ESCAPE BREATHING APPARATUS LOCATIONS.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 30 June 1992 Resolved
RENEW SECTION OF BALLAST DISCHARGE PIPING PORTSIDE THAT HAS PATCH WELDED INPLACE.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Accommodation/Occupational Safety
Issued 27 June 1989 Resolved
REPLACE SANITARY WATER HYDROPNUEMATIC TANK.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Deck/Cargo
Issued 27 June 1989 Resolved
REMOVE AND PROVIDE DOCUMENTATION OF SATISFACTORY TEST OF PRESSURE RELIEF VALVES FOR THIRTEEN (13) HAZARDOUS CARGO TANKS. ENSURE RELIEVING PRESSURE IS PERMANENTLY AFFIXED TO EACH VALVE BODY.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Deck/Cargo
Issued 27 June 1989 Resolved
DEMONSTRATE PROPER OPERATION OF CHEMICAL MIXING SYSTEM SHUTDOWNS FROM BOTH OPERATING STATIONS.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Construction/Loadline
Issued 27 June 1989 Resolved
RENEW DECK VALVE FOR THE PORT POTABLE WATER INTAKE FITTING.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Documentation
Issued 27 June 1989 Resolved
PROVIDE PROOF OF SUBMITTAL OF A CHEMICAL DATA SHEET (CG-4355) ON 'INFLO 40'TO COMMANDANT (G-MTH-1), U.S. COAST GUARD, WASHINTON D.C. 20593-0001
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Lifesaving
Issued 27 June 1989 Resolved
REPAIR OR RENEW AS ORIGINAL THE CABLE SLING FOR THE RESCUE BOAT.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Documentation
Issued 15 November 1987 Resolved
SUBMIT CG-4355 TO COMMANDANT(G-MTH-1) FOR THE CARRIAGE OF AMMONIUM FLORIDE,INFLO 40, CLATROL 3, PARAVAN 23, PARAVAN 22, PARAVAN 19, NE-18, NE-10, CI-25, CI-23, CI-21.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987
Deck/Cargo
Issued 15 November 1987 Resolved
SUBMIT PLANS OF ALL PIPING SYSTEMS FOR THE TRANSFER, OR DRAINAGE OF FLAMMABLE, COMBUSTIBLE, OR HAZARDOUS MATERIALS, AND AIR/WATER SUPPLY LINES FOR THE ACIDIZING PACKAGE TO COMMANDANT(G-MSC) FOR APPROVAL.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987
Electrical
Issued 15 November 1987 Resolved
INSTALL LIGHTING FIXTURES THAT ARE CLASS 1, DIVISION 1 RATED ABOVE THE MIXING TANKS LOCATED ON THE PORT SIDE.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987
Construction/Loadline
Issued 15 November 1987 Resolved
RADIOGRAPHICALLY TEST 20% OF ALL WELDED JOINTS FOR THE ACID, XYLENE, AMMONIUM FLORIDE & INFLO 40 TANKS. THE INTERSECTIONS OF GIRTH AND BUTT WELDS MUST BE RADIOGRAPHED AT 100% FOR A DISTANCE OF 8 INCHES OR 10(T) WHICHEVER IS GREATER. ULTRASONIC GUAGING OF THE TANKS IN WASTED AREAS MUST ALSO BE DONE.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987
Deck/Cargo
Issued 15 November 1987 Resolved
INSTALL AN EMERGENCY SHUTDOWN STATION OUTSIDE THE AREA OF CARGO TRANSFER OPERATIONS THAT WOULD SECURE ALL REMOTELY OPERATED VALVES AND PUMP ENGINES.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987
Deck/Cargo
Issued 15 November 1987 Resolved
INSTALL MISSING RELIEF VALVE ON 120 GALLON STORAGE TANK.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987
Documentation
Issued 15 November 1987 Resolved
SUBMIT CALCULATIONS TO COMMANDANT(G-MSC) DEMONSTRATING THAT THE WIND HEELING PROFILE OF THE ACIDIZING PACKAGE AND NITROGEN TANKS MEET THE STABILITY REGULATIONS FOR THIS VESSEL.
Condition: Unknown
Due 15 November 1987
Resolved 15 November 1987

Casualty record · 3

17 April 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2909561
17 June 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 2992372
30 August 2016Routine · role: Acknowledged Pollution Source · activity 5996679
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.