GO PATRIOT

GO PATRIOT is a 2004 offshore supply vessel. The Coast Guard has recorded 37 inspections since 2004, most recently in April 2026, along with 69 deficiencies and 2 casualty investigations between 2008 and 2016.

Records from 2004 to 2026. Most recent: inspection, 15 April 2026.

Built
2004
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8987852 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDJ4988
664008
Flag
UNITED STATES
367783120
Maury page id
psix-664008

Inspections, by type

…with no type recorded3
Years with a record 18 calendar years (2004–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)129.6 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 84 / net 57
ITC dimensions (L × B × D)129.6 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 442 / net 132
BuilderMASTER BOAT BUILDERS · CODEN, AL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it442 - Convention (Subpart B), Gross Ton
84 - Regulatory (Subpart C or D), Gross Ton
132 - Convention (Subpart B), Net Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

EX254MMSI 367783120 · expired · exemption · granted 11 September 2019, cancelled 25 May 2024
WDJ4988MMSI 367783120 · active · compulsorily equipped · granted 18 April 2017, expires 18 April 2027
WDG7587MMSI 367568780 · expired · compulsorily equipped · granted 4 April 2013, cancelled 10 June 2023
WDB6876MMSI 366932160 · expired · compulsorily equipped · granted 17 March 2004, cancelled 17 May 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KELLY MORRISON Industrial Vessel · MISLE 54884 · 30 August 2016 · activity 5996679

Inspection history · 37

15 April 2026 Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8350688
1 May 2025 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8105317
1 May 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8109492
21 April 2025 Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8097536
5 March 2024 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7874417
11 April 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7666570
17 March 2023 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7652440
14 November 2022 In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7590868
14 April 2022 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7430825
14 April 2022 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7436047
26 January 2022 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385857
12 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7254075
19 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7200716
16 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175176
7 April 2021 Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169935
3 March 2020 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919473
29 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6697775
19 April 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6666361
13 March 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6371262
9 March 2018 Cargo Tank Internal · Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6368853
4 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6281327
18 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6127064
26 October 2016 Administrative Inspection · Deficiency Check · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6030348
30 August 2016 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5996679
4 April 2016 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5847214
16 September 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5720886
3 March 2009 Administrative Inspection · Cargo Tank Internal · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3431022
11 June 2008 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3233945
11 June 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3973234
10 June 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3623160
18 May 2007 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2933750
18 May 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2933764
22 March 2007 Internal Structural Exam · Examination of Repairs · Periodic Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2892871
16 May 2006 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2650900
22 March 2005 MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2316245
9 March 2004 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight · Internal Structural Exam · Cargo Tank Internal
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2020664
8 March 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2021105

Deficiency record · 69

01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 21 April 2025 Resolved
All U.S.-flagged vessels which engage in domestic voyages by sea shall be subject to the applicable regulations regarding Load Line. The vessel has not completed the annual Load Line survey. Complete Load Line survey with Class prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 April 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 21 April 2025 Resolved
Bulkheads or decks of the "A" Class shall be composed of steel or equivalent metal construction, suitably stiffened and made intact with the main structure of the vessel, such as shell, structural bulkheads and decks. They shall be so constructed that, if subjected to the standard fire test, they would be capable of preventing the passage of smoke and flame for 1 hour. Forward bulkhead in engine room lacks proper structural fire protection for wire run. Properly install structural fire protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 April 2025 Resolved
All systems for detecting smoke and fire, including sensors and alarms, must be inspected and tested. Smoke detectors in several state rooms were not operating. Replace batteries or replace with new detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 21 April 2025 Resolved
Emergency lighting must be marked with a letter "E" at least 1/2" high. The emergency light from bow thruster space to stairway leading to main deck is missing letter "E".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2025 Resolved
Each connection to a battery terminal must be made with a permanent connector, rather than with spring clips or other temporary clamps. Batteries behind the wheelhouse have wing nuts, which are not considered permanent connectors. Replace with permanent connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 April 2025 Resolved
Each vessel must have an amplifier-type announcing system that will supplement the general emergency alarm. PA system is not amplifying in galley area. Repair so speaker is operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2024 Resolved
b) Construction. Bells and gongs shall be made of corrosion-resistant material and designed to give clear tone. The diameter of the mouth of the bell shall be not less than 300 mm for vessels of 20 meters or more in length. Bell found to be less than 300 mm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 14 March 2024
Resolution: Ships bell of required size installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 5 March 2024 Resolved
Except as provided by this part, the design, installation, testing, and inspection of materials, machinery, pressure vessels, and piping for OSVs of less than 6,000 GT ITC (500 GRT if GT ITC is not assigned) must comply with subchapter F of this chapter. Bilge overboard discharge pipe found to be improperly repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 14 March 2024
Resolution: Cropped and replaced affected section of bilge discharge piping.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 March 2024 Resolved
4.06-15 Accessibility of chemical testing devices. (a) Alcohol testing. (1) The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol test strips were found to be expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2024
Resolved 14 March 2024
Resolution: Non-expired lcohol test strips provided.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 5 March 2024 Resolved
§ 143.405 Equipment. (a) Standby vessels must have, at least, the following equipment: (8) A scramble net that can be rigged on either side of the standby vessel. No scramble net onboard. Obtain scramble net prior to engaging in stand-by vessel ops.
Action required: 705 - Other - as specified
Due 5 April 2024
Resolved 14 March 2024
Resolution: Scramble net provided and rigged for stand-by ops.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 April 2022 Resolved
After loading but before departure, and at other times necessary to assure the safety of the vessel, the master shall verify that the vessel complies with requirements of its stability letter, Certificate of Inspection, and Loadline Certificate, whichever apply, and then enter a statement of the verification in the log book. The vessel may not leave port until it is in compliance with these requirements. Master was not capturing above and below deck cargo to complete an accurate stability assessment. 46 CFR 131.513(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2022
Resolution: Capt provided cargo capacities to obtain accurate stability assessment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2022 Resolved
Vessel shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil and water tanks which have acceptable means for filling and emptying independent of the bilge system. Engine room bilge suction valve was damaged preventing its operation by hand. 46 CFR 56.50(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Port Capt provided purchase invoice for new bilge valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2022 Resolved
Tests and inspections of lifesaving equipment shall be carried out during each inspection for renewal of certification and shall demonstrate the proper condition of flotation equipment such as lifebuoys. Port lifebuoy line was deteriorated and easily pulled apart. 46 CFR 133.45 (b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Port Capt provided purchase invoice for new lifebouy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 April 2022 Resolved
Where pressure-indicating gages are used the size of the visual display in no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Pressure vessels had gauges installed with a max reading of 200 psi and the same psi as the relieving devices. 46 CFR 54.15-5(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: New gauges were installed that were within the 1.2 and 2 times range of the relieving device.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 April 2022 Resolved
Emergency lighting must be marked with a letter “E” at least 13 millimeters (1/2-inch) high. Several E-Lights throughout vessel were not stenciled. 46 CFR 131.840
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: "E" were stenciled on emergency lights as indicated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2019 Resolved
Power take off on starboard SSDG is not operable. PTO does not disengage from cargo pump causing the cargo pump to run everytime the generator is running. 33CFR155.730
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 29 May 2019 Resolved
EPIRB battery was expired. 46 CFR 94.60
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 May 2019 Resolved
SSDG ground detection on switchboard not operable. Vessel must ensure gauge operates. 46 CFR 111.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2019 Resolved
Overspeed on starboard SSDG did not properly secure the generator. Ensure the overspeed trip device is operable. 46CFR111.12-1
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2019 Resolved
Gaskets in both engine room WTD's and engine room not serviceable and do not provide watertight integrity. Replace gaskets. 46CFR174.195
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2019 Resolved
Stuffing tube in engine room bulkhead is not watertight. Vessel must ensure bulkhead penetration above aft engine room WTD is watertight. 46CFR174.195
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2019 Resolved
Hoses on portable CO2 extinguishers in the machinery passageway & engine room, and hose on paint lockers CO2 extinguisher are cracked/not serviceable. 46CFR95.50
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 May 2019 Resolved
Line throwing gun is not equipped w/ 500 feet of auxiliary line, & it is missing 03 service projectiles. Vessel must acquire these items. 46CFR160.031-4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 30 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 May 2019 Resolved
Anchor light on vessel is obstructed. Vessel must ensure light is visible a full 360 degrees. 33CFR84.15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 26 August 2019
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 29 May 2019 Resolved
Vessel is missing deck line. Vessel must ensure load lines are painted in accordance with loadline certificate. 46CFR42.13-40
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2019 Resolved
Vessel is missing instruction placard for liferafts posted nearby the rafts. Vessel must post placards at every liferaft. 46CFR199.80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2019 Resolved
Port SSDG was leaking fuel oil during operation. Vessel must ensure SSDG does not leak excessive fuel oil during operation. 46CFR56.50-75
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 May 2019 Resolved
Vessel needs to provide proof of last tailshaft examination.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 31 July 2019
Resolution: Added special note for the tailshafts to be removed for inspection no later than the next scheduled dry dock exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 29 May 2019 Resolved
Provide emergency steering training to crew on operation of the emergency steering system. 46CFR97.37-33
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
Fire Fighting › Fire Pumps › Pressure
Issued 13 March 2018 Resolved
Provide proper operation of fire pump and fire monitor.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Resolution: Witnessed fire pump and fire monitor pump. Fire pump produced 100 p.s.i. with two (02) hoses. Fire monitor produced 165 p.s.i.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 March 2018 Resolved
Bow thruster hallway bilge alarm inoperable. Provide proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Resolution: Bilge alarm pulled and witnessed and heard alarm on bridge
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 13 March 2018 Resolved
Rudder angle indicator off from proper reading. Readjust and provide proper operation.
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 15 March 2018
Resolution: Witnessed test of rudder operations. Verified readings on bridge matched engine room readings.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2018 Resolved
Secure hoses and wiring on port and stbd main engines.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Resolution: Witnessed all hoses and wiring on both engines secured properly
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 4 November 2016 Resolved
Obtain and provide onboard a Non Tank Vessel Response Plan approval letter (33 CFR Part 155, Subpart J), and Shipboard Oil Pollution Emergency Plan (SOPEP)/ Shipboard Marine Pollution Emergency Plan (SMPEP) approval letter (33 CFR 151.09/151.30).
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 4 November 2016
Resolution: NTVRP approval letter issued 04Nov2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 October 2016 Resolved
Vessel exceeded 3 month window after COI anniversary date to conduct periodic inspection by 1 month and 20 days. Complete satisfactory periodic vessel inspection in accordance with 46 CFR 126.510.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Endorsed COI.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 October 2016 Resolved
Vessel's non-tank vessel response plan (NTVRP) expired 17May2015. Submit NTVRP for Coast Guard approval in accordance with 33 CFR Part 155, Subpart J. Owner/ operator must identify Qualified Individual and alternate (33 CFR 155.5026), OSRO and provide written consent (33 CFR 155.5050), and salvor and written consent (33 CFR 155.5050) prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Plan submitted and under expedited review.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 26 October 2016 Resolved
Vessel SOPEP/SMPEP expired 21May2014. Submit SOPEP/SMPEP for Coast Guard approval in accordance with 33 CFR 151.09/151.30 prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: SMPEP submitted to Coast Guard and under review.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 October 2016 Resolved
Vessel does not have onboard a lifesaving equipment maintenance record and does not log maintenance. Provide onboard lifesaving equipment maintenance checklist in accordance with 46 CFR 131.545(a)(1) and log tests and inspections in accordance with 46 CFR 131.565.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Checklist and maintenance record developed and onboard.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 26 October 2016 Resolved
Provide onboard a Notice of Intent for EPA Vessel General Permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 3 November 2016
Resolution: NOI onboard.
Communications › Internal Communications System › Sound-powered Telephone
Issued 26 October 2016 Resolved
Provide proper operation of fixed means of communication between the pilothouse and local steering control in engineering room per 46 CFR 130.110.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Replaced damaged sound powered phone.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 October 2016 Resolved
Repair and prove operation of pilothouse fire detection panel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 3 November 2016
Resolution: Fire detection panel replaced. Witnessed proper operation of fire detection system.
Lifesaving › Lifefloat › Float-free Link
Issued 26 October 2016 Resolved
Provide proper arrangement of life floats in accordance with 46 CFR 133.105. Float-free link was inadequate for total capacity, floating water light lines were not attached to body of the raft, painter line was not directly attached to float.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 3 November 2016
Resolution: Replaced weak link; witnessed proper lifefloat arrangement.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 October 2016 Resolved
Vessel's transfer procedures are incomplete. Update transfer procedures contents in accordance with 33 CFR 155.750 and make available onboard per 33 CFR 155.740.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 13 February 2017
Resolution: Transfer procedures updated and posted onboard.
Construction/Loadline › Structures › Scuttle
Issued 26 October 2016 Resolved
Make engine room escape hatch watertight in accordance with 46 CFR 42.15.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 26 October 2016
Resolution: Corrected during inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 26 October 2016 Resolved
Provide proper sealing and operation of port stack vent cover.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 26 October 2016
Resolution: Corrected during inspection.
Lifesaving › Lifebuoys › Approval
Issued 26 October 2016 Resolved
Prove proper arrangement of retro reflective tape on all ring buoys in accordance with 46 CFR 131.875.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 31 October 2016
Resolution: Corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 26 October 2016 Resolved
Prove proper condition of flame screens on fuel vents in accordance with 46 CFR 56.50-85.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Flame screens replaced.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 September 2015 Resolved
No record of a VRP
Due 15 October 2015
Resolved 28 September 2015
Resolution: The approved VRP is currently on board. All sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 September 2015 Resolved
The secondary mast head light was inop.
Due 2 October 2015
Resolved 18 September 2015
Resolution: Replaced lamp, all sat.
Stability › Watertight Integrity › General
Issued 16 September 2015 Resolved
The fwd engine room water tight bulkhead had several openings in the cable penetration.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2015
Resolved 18 September 2015
Resolution: The cable penetration was sealed in all open places, all sat.
Engineering › Diesel Engine (auxiliary) › Block
Issued 16 September 2015 Resolved
The bow thruster engine gear cover was duct taped on. Install cover with proper mounting hardware.
Due 15 October 2015
Resolved 18 September 2015
Resolution: Installed gear cover with proper hardware, all sat.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 16 September 2015 Resolved
The sewage overboard discharge valve was not locked in the closed position.
Due 15 October 2015
Resolved 18 September 2015
Resolution: The valve is secured with lock and chain.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 16 September 2015 Resolved
The chem-light on one life jacket was expired.
Due 2 October 2015
Resolved 18 September 2015
Resolution: Replaced chem light with new light that expires in 2018
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 September 2015 Resolved
Both generator overspeed devices are inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2015
Resolution: Adjusted overspeed devices, tested sat.
Communications › Radio Communications › EPIRB
Issued 10 March 2009 Resolved
Replace expired battery in EPRIB prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: Received email with receipt and new registration for EPRIB.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 March 2009 Resolved
Renbew OSHA approved safety harness for use during man overboard recovery.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: Received email stating that the new harness has been purchased and placed on the vessel
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 March 2007 Resolved
The hydraulic hose connection in the aft deck steering system was not tightened and caused a hydraulic fluid leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 9 March 2004 Resolved
Install chafing gear on the power supply cable for engine room panel P-3.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 9 March 2004
Engineering › Diesel Engine (auxiliary)
Issued 9 March 2004 Resolved
Properly install fuel hose for the port generator to remove severe kink. LEGACY COMPONENT DESC: fuel line
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 9 March 2004
Resolution: hose rerouted.
Engineering › Diesel Engine (auxiliary)
Issued 9 March 2004 Resolved
Properly install starboard generator fuel supply line to stop fuel leak and move hose off of foundation. LEGACY COMPONENT DESC: fuel line
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 9 March 2004
Resolution: fuel leak stopped, and chafing gear added at foundation.
Navigation › Piloting/Steering
Issued 9 March 2004 Resolved
Provide all missing navigation publications and charts. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2004
Resolved 12 March 2004
Resolution: Provided
Operations/Management › Drills/Instruction
Issued 9 March 2004 Resolved
Conduct fire drill in the presence of a marine inspector. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2004
Resolved 12 March 2004
Resolution: Satisfactory drill witnessed
Operations/Management › Drills/Instruction
Issued 9 March 2004 Resolved
Conduct abandon ship drill in the presence of a marine inspector. LEGACY COMPONENT DESC: Abandon Ship
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2004
Resolved 12 March 2004
Resolution: Satisfactory drill witnessed.
Electrical › Electric Supply System (service)
Issued 9 March 2004 Resolved
Install fuses at or near each battery. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 12 March 2004
Resolution: Fuses installed
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 March 2004 Resolved
Provide and install oil dip stick for the port main engine. LEGACY COMPONENT DESC: dip stick
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2004
Resolved 12 March 2004
Resolution: Provided and installed
Engineering › Diesel Engine (auxiliary)
Issued 9 March 2004 Resolved
Properly secure the hydraulic hoses for the bow thruster controls at the bow thruster drive shaft. LEGACY COMPONENT DESC: hydraulic hoses
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2004
Resolved 12 March 2004
Resolution: Hoses secured.
Navigation › Emergency Steering
Issued 9 March 2004 Resolved
Provide and install control wheel for the second engine room back-up (manual) steering system. LEGACY COMPONENT DESC: wheel
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2004
Resolved 12 March 2004
Resolution: Provided and tested.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 March 2004 Resolved
Remove plates blocking natural ventilation accesses for the methanol pump deck box or install proper fixed fire fighting system. LEGACY COMPONENT DESC: Pumproom Ventilation
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2004
Resolved 12 March 2004
Resolution: Second vent installed.
Lifesaving › Buoyant Apparatus
Issued 9 March 2004 Resolved
Properly label second life float. LEGACY COMPONENT DESC: Label lifefloats
Action required: 705 - Other - as specified
Due 12 March 2004
Resolved 12 March 2004
Resolution: Completed.

Casualty record · 2

11 June 2008Routine · role: Involved in a Marine Casualty · activity 3973234
30 August 2016Routine · role: Involved in a Marine Casualty · activity 5996679
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

TINA CALLAIS (2008), BALTY (2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.