Inspection history · 25
15 April 2026
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8350688
1 May 2025
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8105317
1 May 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8109492
21 April 2025
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8097536
5 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7874417
11 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7666570
17 March 2023
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7652440
14 November 2022
In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7590868
14 April 2022
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7430825
14 April 2022
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7436047
26 January 2022
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385857
12 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7254075
19 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7200716
16 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175176
7 April 2021
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169935
3 March 2020
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919473
29 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6697775
19 April 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6666361
13 March 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6371262
9 March 2018
Cargo Tank Internal · Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6368853
4 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6281327
18 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6127064
26 October 2016
Administrative Inspection · Deficiency Check · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6030348
30 August 2016
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5996679
4 April 2016
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5847214
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 21 April 2025
Resolved
All U.S.-flagged vessels which engage in domestic voyages by sea shall be subject to the applicable regulations regarding Load Line. The vessel has not completed the annual Load Line survey. Complete Load Line survey with Class prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 April 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 21 April 2025
Resolved
Bulkheads or decks of the "A" Class shall be composed of steel or equivalent metal construction, suitably stiffened and made intact with the main structure of the vessel, such as shell, structural bulkheads and decks. They shall be so constructed that, if subjected to the standard fire test, they would be capable of preventing the passage of smoke and flame for 1 hour. Forward bulkhead in engine room lacks proper structural fire protection for wire run. Properly install structural fire protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 April 2025
Resolved
All systems for detecting smoke and fire, including sensors and alarms, must be inspected and tested. Smoke detectors in several state rooms were not operating. Replace batteries or replace with new detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 21 April 2025
Resolved
Emergency lighting must be marked with a letter "E" at least 1/2" high. The emergency light from bow thruster space to stairway leading to main deck is missing letter "E".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2025
Resolved
Each connection to a battery terminal must be made with a permanent connector, rather than with spring clips or other temporary clamps. Batteries behind the wheelhouse have wing nuts, which are not considered permanent connectors. Replace with permanent connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 April 2025
Resolved
Each vessel must have an amplifier-type announcing system that will supplement the general emergency alarm. PA system is not amplifying in galley area. Repair so speaker is operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 25 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2024
Resolved
b) Construction. Bells and gongs shall be made of corrosion-resistant material and designed to give clear tone. The diameter of the mouth of the bell shall be not less than 300 mm for vessels of 20 meters or more in length. Bell found to be less than 300 mm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 14 March 2024
Resolution: Ships bell of required size installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 5 March 2024
Resolved
Except as provided by this part, the design, installation, testing, and inspection of materials, machinery, pressure vessels, and piping for OSVs of less than 6,000 GT ITC (500 GRT if GT ITC is not assigned) must comply with subchapter F of this chapter. Bilge overboard discharge pipe found to be improperly repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 14 March 2024
Resolution: Cropped and replaced affected section of bilge discharge piping.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 March 2024
Resolved
4.06-15 Accessibility of chemical testing devices.
(a) Alcohol testing. (1) The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol test strips were found to be expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2024
Resolved 14 March 2024
Resolution: Non-expired lcohol test strips provided.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 5 March 2024
Resolved
§ 143.405 Equipment.
(a) Standby vessels must have, at least, the following equipment: (8) A scramble net that can be rigged on either side of the standby vessel. No scramble net onboard. Obtain scramble net prior to engaging in stand-by vessel ops.
Action required: 705 - Other - as specified
Due 5 April 2024
Resolved 14 March 2024
Resolution: Scramble net provided and rigged for stand-by ops.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 April 2022
Resolved
After loading but before departure, and at other times necessary to assure the safety of the vessel, the master shall verify that the vessel complies with requirements of its stability letter, Certificate of Inspection, and Loadline Certificate, whichever apply, and then enter a statement of the verification in the log book. The vessel may not leave port until it is in compliance with these requirements. Master was not capturing above and below deck cargo to complete an accurate stability assessment. 46 CFR 131.513(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2022
Resolution: Capt provided cargo capacities to obtain accurate stability assessment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2022
Resolved
Vessel shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil and water tanks which have acceptable means for filling and emptying independent of the bilge system. Engine room bilge suction valve was damaged preventing its operation by hand. 46 CFR 56.50(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Port Capt provided purchase invoice for new bilge valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2022
Resolved
Tests and inspections of lifesaving equipment shall be carried out during each inspection for renewal of certification and shall demonstrate the proper condition of flotation equipment such as lifebuoys. Port lifebuoy line was deteriorated and easily pulled apart. 46 CFR 133.45 (b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: Port Capt provided purchase invoice for new lifebouy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 April 2022
Resolved
Where pressure-indicating gages are used the size of the visual display in no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Pressure vessels had gauges installed with a max reading of 200 psi and the same psi as the relieving devices. 46 CFR 54.15-5(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: New gauges were installed that were within the 1.2 and 2 times range of the relieving device.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 April 2022
Resolved
Emergency lighting must be marked with a letter “E” at least 13 millimeters (1/2-inch) high. Several E-Lights throughout vessel were not stenciled. 46 CFR 131.840
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2022
Resolution: "E" were stenciled on emergency lights as indicated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2019
Resolved
Power take off on starboard SSDG is not operable. PTO does not disengage from cargo pump causing the cargo pump to run everytime the generator is running.
33CFR155.730
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 29 May 2019
Resolved
EPIRB battery was expired.
46 CFR 94.60
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 May 2019
Resolved
SSDG ground detection on switchboard not operable. Vessel must ensure gauge operates. 46 CFR 111.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2019
Resolved
Overspeed on starboard SSDG did not properly secure the generator. Ensure the overspeed trip device is operable.
46CFR111.12-1
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2019
Resolved
Gaskets in both engine room WTD's and engine room not serviceable and do not provide watertight integrity. Replace gaskets.
46CFR174.195
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2019
Resolved
Stuffing tube in engine room bulkhead is not watertight. Vessel must ensure bulkhead penetration above aft engine room WTD is watertight.
46CFR174.195
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2019
Resolved
Hoses on portable CO2 extinguishers in the machinery passageway & engine room, and hose on paint lockers CO2 extinguisher are cracked/not serviceable.
46CFR95.50
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 May 2019
Resolved
Line throwing gun is not equipped w/ 500 feet of auxiliary line, & it is missing 03 service projectiles. Vessel must acquire these items.
46CFR160.031-4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 30 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 May 2019
Resolved
Anchor light on vessel is obstructed. Vessel must ensure light is visible a full 360 degrees.
33CFR84.15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 26 August 2019
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 29 May 2019
Resolved
Vessel is missing deck line. Vessel must ensure load lines are painted in accordance with loadline certificate.
46CFR42.13-40
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2019
Resolved
Vessel is missing instruction placard for liferafts posted nearby the rafts. Vessel must post placards at every liferaft.
46CFR199.80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2019
Resolved
Port SSDG was leaking fuel oil during operation. Vessel must ensure SSDG does not leak excessive fuel oil during operation.
46CFR56.50-75
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 30 May 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 May 2019
Resolved
Vessel needs to provide proof of last tailshaft examination.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 31 July 2019
Resolution: Added special note for the tailshafts to be removed for inspection no later than the next scheduled dry dock exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 29 May 2019
Resolved
Provide emergency steering training to crew on operation of the emergency steering system.
46CFR97.37-33
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 30 May 2019
Fire Fighting › Fire Pumps › Pressure
Issued 13 March 2018
Resolved
Provide proper operation of fire pump and fire monitor.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Resolution: Witnessed fire pump and fire monitor pump. Fire pump produced 100 p.s.i. with two (02) hoses. Fire monitor produced 165 p.s.i.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 March 2018
Resolved
Bow thruster hallway bilge alarm inoperable. Provide proper operation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Resolution: Bilge alarm pulled and witnessed and heard alarm on bridge
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 13 March 2018
Resolved
Rudder angle indicator off from proper reading. Readjust and provide proper operation.
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 15 March 2018
Resolution: Witnessed test of rudder operations. Verified readings on bridge matched engine room readings.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 March 2018
Resolved
Secure hoses and wiring on port and stbd main engines.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Resolution: Witnessed all hoses and wiring on both engines secured properly
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 4 November 2016
Resolved
Obtain and provide onboard a Non Tank Vessel Response Plan approval letter (33 CFR Part 155, Subpart J), and Shipboard Oil Pollution Emergency Plan (SOPEP)/ Shipboard Marine Pollution Emergency Plan (SMPEP) approval letter (33 CFR 151.09/151.30).
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 4 November 2016
Resolution: NTVRP approval letter issued 04Nov2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 October 2016
Resolved
Vessel exceeded 3 month window after COI anniversary date to conduct periodic inspection by 1 month and 20 days. Complete satisfactory periodic vessel inspection in accordance with 46 CFR 126.510.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Endorsed COI.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 October 2016
Resolved
Vessel's non-tank vessel response plan (NTVRP) expired 17May2015. Submit NTVRP for Coast Guard approval in accordance with 33 CFR Part 155, Subpart J. Owner/ operator must identify Qualified Individual and alternate (33 CFR 155.5026), OSRO and provide written consent (33 CFR 155.5050), and salvor and written consent (33 CFR 155.5050) prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Plan submitted and under expedited review.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 26 October 2016
Resolved
Vessel SOPEP/SMPEP expired 21May2014. Submit SOPEP/SMPEP for Coast Guard approval in accordance with 33 CFR 151.09/151.30 prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: SMPEP submitted to Coast Guard and under review.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 October 2016
Resolved
Vessel does not have onboard a lifesaving equipment maintenance record and does not log maintenance. Provide onboard lifesaving equipment maintenance checklist in accordance with 46 CFR 131.545(a)(1) and log tests and inspections in accordance with 46 CFR 131.565.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Checklist and maintenance record developed and onboard.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 26 October 2016
Resolved
Provide onboard a Notice of Intent for EPA Vessel General Permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 3 November 2016
Resolution: NOI onboard.
Communications › Internal Communications System › Sound-powered Telephone
Issued 26 October 2016
Resolved
Provide proper operation of fixed means of communication between the pilothouse and local steering control in engineering room per 46 CFR 130.110.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Replaced damaged sound powered phone.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 October 2016
Resolved
Repair and prove operation of pilothouse fire detection panel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 3 November 2016
Resolution: Fire detection panel replaced. Witnessed proper operation of fire detection system.
Lifesaving › Lifefloat › Float-free Link
Issued 26 October 2016
Resolved
Provide proper arrangement of life floats in accordance with 46 CFR 133.105. Float-free link was inadequate for total capacity, floating water light lines were not attached to body of the raft, painter line was not directly attached to float.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 3 November 2016
Resolution: Replaced weak link; witnessed proper lifefloat arrangement.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 October 2016
Resolved
Vessel's transfer procedures are incomplete. Update transfer procedures contents in accordance with 33 CFR 155.750 and make available onboard per 33 CFR 155.740.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 13 February 2017
Resolution: Transfer procedures updated and posted onboard.
Construction/Loadline › Structures › Scuttle
Issued 26 October 2016
Resolved
Make engine room escape hatch watertight in accordance with 46 CFR 42.15.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 26 October 2016
Resolution: Corrected during inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 26 October 2016
Resolved
Provide proper sealing and operation of port stack vent cover.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 26 October 2016
Resolution: Corrected during inspection.
Lifesaving › Lifebuoys › Approval
Issued 26 October 2016
Resolved
Prove proper arrangement of retro reflective tape on all ring buoys in accordance with 46 CFR 131.875.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 31 October 2016
Resolution: Corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 26 October 2016
Resolved
Prove proper condition of flame screens on fuel vents in accordance with 46 CFR 56.50-85.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2016
Resolved 4 November 2016
Resolution: Flame screens replaced.