RED ROOSTER III

RED ROOSTER III is a 1982 passenger vessel (inspected). The Coast Guard has recorded 159 inspections since 1985, most recently in June 2026, along with 175 deficiencies, 2 operational controls and 12 casualty investigations between 2002 and 2026.

Records from 1985 to 2026. Most recent: inspection, 20 June 2026.

Built
1982
Last inspected
20 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8744327 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY3865
Flag
UNITED STATES
366749490
Maury page id
psix-54910

Inspections, by type

…with no type recorded44
Years with a record 40 calendar years (1985–2026)
The 159 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)91.3 ft × 26.5 ft × 11.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)91.3 ft × 26.5 ft × 11.0 ft
ITC tonnagegross 185 / net 55
BuilderPOOLE BOAT COMPANY INC · CHULA VISTA, CA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it185 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
55 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY3865MMSI 366749490 · active · compulsorily equipped · granted 18 April 2018, expires 15 May 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CONSTITUTION Passenger (Inspected) · MISLE 371674 · 22 May 2012 · activity 4321741

Inspection history · 159

20 June 2026 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8410622
10 June 2026 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8367444
2 April 2026 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8309725
22 January 2026 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8300379
10 June 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8135693
2 April 2025 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8103635
28 October 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8026751
12 June 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7937196
29 May 2024 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7923208
2 April 2024 Internal Structural Exam · Hull Examination · Inclining Experiment
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7889063
18 October 2023 Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7810857
6 September 2023 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7787948
24 May 2023 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7690320
10 April 2023 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7670226
3 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662119
6 December 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7605281
17 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7578898
30 September 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7569558
30 September 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7624105
28 May 2022 Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7469272
25 May 2022 MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7458156
25 March 2022 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7418567
23 March 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504150
20 January 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7383353
23 September 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319102
19 May 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188241
8 April 2021 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7172165
17 June 2020 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6974917
7 April 2020 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6955386
4 February 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903284
6 November 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6849555
19 June 2019 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6717545
18 March 2019 Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6660391
27 September 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6550172
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548009
23 May 2018 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6414487
9 April 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6387883
24 May 2017 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6148358
15 May 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6163737
5 April 2017 Administrative Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6118240
23 May 2016 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5884242
5 April 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5847581
19 May 2014 COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4862587
6 July 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4370127
23 May 2012 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4319740
22 May 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4321741
7 May 2012 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4304812
29 September 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4157594
26 March 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3703451
26 March 2010 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3703454
24 April 2009 Administrative Inspection · Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3454534
9 February 2009 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3415026
1 February 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3417583
30 May 2008 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3225154
19 May 2008 Administrative Inspection · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3181557
28 April 2008 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3181548
25 April 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3235216
14 November 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3104687
25 April 2007 Deficiency Check · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2900751
28 March 2007 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2882670
14 March 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3107475
31 January 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2892171
15 August 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2777302
31 May 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2666700
24 April 2006 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2619697
6 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2618403
30 March 2006 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2603547
12 July 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2424125
27 May 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2390740
17 May 2005 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2360377
10 May 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2345135
4 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2349092
22 March 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2290364
26 July 2004 Deficiency Check · MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2145580
19 July 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2148081
30 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2116865
14 May 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2064061
11 March 2004 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2022961
9 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1981618
3 October 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1920757
11 June 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1815192
2 May 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1784218
8 April 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1768266
21 February 2003 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1747855
3 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714323
10 September 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1673583
12 June 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1630127
29 April 2002 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1605603
31 January 2002 Deficiency Check · Excursion Permit
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1482862
13 July 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 176867
28 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067384
28 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373530
3 May 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1420512
20 April 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467284
27 March 2001 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1060757
28 July 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 824049
23 June 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 818809
25 May 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 819412
3 May 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1410303
30 March 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1449305
7 July 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1092252
7 June 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1451410
4 June 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 118546
30 April 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461149
8 April 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386502
31 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 18938
3 January 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 211107
3 January 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 754509
2 December 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 32206
20 October 1998 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372398
17 October 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 113880
26 June 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1129052
6 May 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1465393
22 April 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375371
12 November 1997 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 784567
7 September 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 785772
19 May 1997 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1465916
21 March 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213428
24 February 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1435874
17 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 114367
18 July 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 230823
18 July 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1383294
15 May 1996 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374729
13 October 1995 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 882615
31 August 1995 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1182452
4 May 1995 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409291
3 May 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377197
15 April 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1422376
29 March 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 664134
4 May 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 831612
4 May 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 836598
15 April 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1147936
8 May 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1267750
30 March 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1258627
22 October 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 942511
26 June 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225644
29 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1216193
8 May 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1232595
15 April 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 902898
15 May 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1232854
13 April 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 923726
14 December 1989 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1232403
23 May 1989 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 895238
11 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1045315
8 May 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1196568
4 April 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1347675
6 June 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 888911
31 May 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 886868
12 May 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1348423
18 April 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1202730
28 May 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1026457
20 May 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1336105
15 December 1986 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1332569
22 May 1986 Credit Drydock · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 998056
1 May 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1001565
21 April 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 998642
28 October 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1304089
16 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 981844
10 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 981842

Deficiency record · 175

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 May 2024 Resolved
Vessel does not have current stability letter.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2024
Resolution: Vessel was issued a new stability letter by MSC.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 May 2024 Resolved
Vessel EPIRB hydro expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2024
Resolution: Observed new EPIRB's hyro-static release
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2024 Resolved
Vessel Safety Radio certificate expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 17 June 2024
Resolution: observed FCC certificate
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 May 2024 Resolved
Vessel master could not prove LRIT was transmitting position.
Condition: Invalid
Action required: 702 - Prior to embarking on international voyage
Resolved 17 June 2024
Resolution: observed LRIT transmission
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 29 May 2024 Resolved
Vessel SSB non operational.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 17 June 2024
Resolution: observed operational test of MF/HF radio
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022 Resolved
On May 25, 2022, an 835 was issued stating "Main Salon rod reel line spool machine unit has multiple cable splices in power cord. Reel spool machine unit power cord must be of an approved type per its manufacturer. Must replace cable or remove unit." On September 30, 2022 the vessel was found to have the spool machine back on board and in service. Equipment must be removed prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2022
Resolution: SSD MI's verified the equipment was no longer onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 September 2022 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit. Stateroom H was found to have a smoke detector without a battery after attempting to test it. Vessel must replace battery and ensure unit is operational in addition to testing and ensuring proper operation of all smoke detectors onboard prior to carriage of passengers. Licensed Mariner must provide statement in writing, signed with their MMC Reference # to the full operability and completion of satisfactory testing on all smoke detectors onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2022
Resolution: Vessel previded attestation that all vessels smoke detectors were tested and operational, in addition Mi's conducted a spot check and verified the operation of two random smoke detectors.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 September 2022 Resolved
AIS must be maintained in effective operating condition, which includes the continual operation of AIS and its associated devices at all times while the vessel is underway or at anchor, and, if moored at least 15 minutes prior to getting underway. The AIS installed on board was not transmitting and has not been transmitting since January 2, 2022. The vessels AIS was found in the off position at the time of the in service inspection but when it was turned on the AIS was still not transmitting. Vessel must ensure AIS is operating as designed. The vessel must rectify prior to the carriage of passengers after October 8, 2022.
Action required: 705 - Other - as specified
Resolved 8 October 2022
Resolution: Verified through JHOC and onscene that all systems are working. DEM
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 30 September 2022 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. The escape hatch from aft passenger berthing was blocked by an anti slip carpet in a manner preventing the usage of the escape hatch.
Action required: 30 - Ship detained
Resolved 30 September 2022
Resolution: Vessel removed the rug that was covering the escape hatches from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2022 Resolved
All vessels on an Oceans Route are required to carry twelve (12) distress flares. Vessel only had nine (9) rocket parachute flares on board at time of inspection. Vessel operator must provide three (3) additional rocket parachute flares prior to sailing on an oceans route.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: POC Provided proof of the appropriate number of flares.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022 Resolved
Topside deck freezer units (3) power cord spliced. Power cord must be of an approved type per its manufacturer. Must replace to satisfaction of CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Corrected. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022 Resolved
Main Salon rod reel line spool machine unit has multiple cable splices in power cord. Reel spool machine unit power cord must be of an approved type per its manufacturer. Must replace cable or remove unit.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Unit unplugged and removed from vessel. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022 Resolved
Port side FWD PAX accommodation room closet; electrical cable has multiple splices; Replace cable.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Replaced electrical cable. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022 Resolved
Fore peak void; Overhead electrical junction box not properly mounted. Must repair to the satisfaction of the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2022
Resolution: Corrected. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022 Resolved
Engine room: following electrical panels not properly sealed: FWD BHD outboard STBD side electrical panel, FWD BHD outboard Port side electrical panel, AFT BHD Outboard Port side electrical panel, SWBD panel light indicator covers (3) missing. Must repair to the satisfaction the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 June 2022
Resolution: Corrected; received pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 May 2021 Resolved
While conducting operational tests of the steering gear, the stbd rudder was making an unusual noise. Upon further investigation it was discovered the upper support bearing was wasted away and failed. Replace bearing and prove proper operation of stbd rudder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: Vessel's crew replaced the upper rudder bearing, conducted steering test at the pier, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2021 Resolved
While conducting fire main / fire hose pressure test, the stbd main deck fire hose ruptured. Replace fire hose with in-kind 1-1/2” UL 19 approved type.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: Vessel's crew repaired fire hose, hoses tested sat under working pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2021 Resolved
While Inspecting life saving appliances discovered 01 Ring Life Buoy deteriorating due to excessive sun damage. Provide vessel with new 24 in. SOLAS approved Ring Life Buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 21 May 2021
Resolution: Vessel rep replaced life ring with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 6 February 2020
Resolved 4 February 2020
Resolution: Vessel submitted A/C one-line drawing, SSD reviewed drawing and conducted accuracy spot check on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 November 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2019
Resolution: Conducted training
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019 Resolved
Electrical equipment on a vessel must be installed to protect persons from electrical hazards. Remove stray cable in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 15 November 2019
Resolution: Dead ended cable was removed from galley.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2019 Resolved
Repair leaking shaft seal on center shaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: New dripless fitting installed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 June 2019 Resolved
Replace expired EPIRB HRU.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: New HRU installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 June 2019 Resolved
Replace expired First Aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: New first aid kit on board.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 June 2019 Resolved
Store O2/Acetylene cylinders on open deck (or remove).
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: Gas cylinders removed from vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019 Resolved
Cover open slots within circuit breaker panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 10 July 2019
Resolution: Pictures used to clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 June 2019 Resolved
Replace inoperable oil pressure gauge on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 10 July 2019
Resolution: Pictures used to clear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019 Resolved
Replace missing cover for electrical panel under helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 10 July 2019
Resolution: Pictures used to clear.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 June 2019 Resolved
Repair cracked longitudinal frame in forepeak stbd side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 21 June 2019
Resolution: Repaired
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 June 2019 Resolved
Correct station bills with proper crew duties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 21 June 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018 Resolved
Port side MDE fuel leak on main fuel return line. Make proper repairs and prove proper operation to attending MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2018
Resolved 27 September 2018
Resolution: Attending MI's operational tested MDE. No leaking present from saudered piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018 Resolved
Stbd side MDE fuel injection line leaking at header #2. Repair and prove proper operation to attending MI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2018
Resolved 27 September 2018
Resolution: MI's witnessed engineer identify loose bolt on individual fuel return lines. Bolt tigtened. Leak stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2018 Resolved
Stbd generator has improper repairs to expansion tank freeze plugs (belzona). Make repairs and prove proper operation to attending MI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2018
Resolved 27 September 2018
Resolution: Freeze plugs installed. Generator operationally tested under load.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018 Resolved
Center MDE oil leaking off port side. Make repairs and prove proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: Replaced fuel pump, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018 Resolved
Center MDE improper repairs to jacket water freeze plug. Make repairs and prove proper operation to attending MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: Freeze plug replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2018 Resolved
Fiberglass observed at MDE shaft logs. Continuously inspect and make permanent repairs at dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 21 June 2019
Resolution: Port & Stbd shaft logs renewed. Center authorized one additional year of use. Special note added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018 Resolved
Port MDE leak on #2 cylinder fuel injection line at flared fitting. Make repairs and prove proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: Replaced fuel line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 September 2018 Resolved
Stbd side fuel day tank sight glass is leaking with temporary repair. Make repairs and prove proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: LTI repaired, tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V), ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS
Fire Fighting › Means of Escape › Doorways
Issued 23 May 2018 Resolved
Provide means of escape from reefer.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 23 May 2018 Resolved
Fill out emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2018 Resolved
Provide current charts and navigation publications.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 13 August 2018
Resolution: Charts onboard
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 23 May 2018 Resolved
Replace smoke detector in fwd bunkroom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Fire Fighting › Firemans Outfit › Axe
Issued 23 May 2018 Resolved
Provide a fire axe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 24 May 2017 Resolved
Provide LRIT conformance test results prior to sailing international.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 June 2017
Communications › Radio Communications › EPIRB
Issued 23 May 2016 Resolved
Prior to operating greater than 3 nm from shore, provide valid EPIRB
Action required: 705 - Other - as specified
Resolved 27 May 2016
Resolution: Attended vessel and verified validity of EPIRB
Communications › Radio Communications › EPIRB
Issued 23 May 2016 Resolved
Prior to operating greater than 3 nm from shore, stow EPIRB in float free location.
Action required: 705 - Other - as specified
Resolved 27 May 2016
Resolution: Attended vessel and verified float free stowage of EPIRB
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2016 Resolved
Provide proper plugs for fuel filter bowls located on stbd side engine room.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified proper metallic plugs fitted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 May 2016 Resolved
Properly terminate all splices under nav console
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified proper termination of splice.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2016 Resolved
Provide burn gel
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified burn gel on board.
Engineering › Fuel Oil Service System › Valve
Issued 23 May 2016 Resolved
Provide emergency fuel shutoff decal
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified Emergency Fuel Shut off now labeled.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 May 2014 Resolved
Complete a satisfactory COI inspection prior to carrying passengers for hire. Vessel's COI expired 20 May 2014.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2014
Resolution: Vessel completed required annual inspection.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2012 Resolved
Make repairs to damaged railing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2012
Resolved 25 May 2012
Resolution: Made repairs to original condition.
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 7 May 2012 Resolved
Vessels O/O has ordered and registered for the equipment associated with the LRIT, but it was not onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2012
Resolved 29 June 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 March 2010 Resolved
Provide fire servicing report for engine room CO2 system
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 June 2010
Resolved 25 May 2010
Fire Fighting › Firemans Outfit › Axe
Issued 26 March 2010 Resolved
Provide a fire ax.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2010
Resolved 28 May 2010
Engineering › Bilge Water Management System › Manifold
Issued 26 March 2010 Resolved
Mark/label bilge manifold valves for spaces of service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2010
Resolved 28 May 2010
Engineering › Steering Gear System › Rudder Stock
Issued 9 February 2009 Resolved
Replace Starboard side ram support arm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2009
Resolution: New arm has been installed
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 February 2009 Resolved
Renew starboard exhaust piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2009
Resolution: Exhaust piping has been replaced
Electrical › Electric Supply System (service) › Cable
Issued 9 February 2009 Resolved
Replace main cable for starboard generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2009
Resolution: Main cable has been repalced
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 May 2008 Resolved
Perform annual servicing of inflatable liferaft (Elliot serial #S3154, Lot 896). Vessel is restricted to 25 persons on international voyages until corrected.
Action required: 705 - Other - as specified
Due 19 May 2008
Resolved 27 May 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 May 2008 Resolved
Provide tidal current tables for areas vessel transits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2008
Resolved 27 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2008 Resolved
Use or remove dead-end wires under pilot station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2008
Resolved 27 May 2008
Fire Fighting › Fire Pumps › Pressure
Issued 19 May 2008 Resolved
Repair/replace inoperative fire pump gage & prove proper operation as per 46 CFR 181.10-1(c) (Existing Vessel).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2008
Resolved 27 May 2008
Engineering › Fuel Oil Service System › Gauge
Issued 19 May 2008 Resolved
Repair fuel leak on portside fuel (flow) meter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2008
Resolved 27 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 May 2008 Resolved
Move fixed fire-fighting system pressure switch to location outside protected space as per CG-approved plan & regulation (46 CFR 181.20-15(a) (Existing Vessel).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2009
Resolved 22 May 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 May 2008 Resolved
Prove proper operation of port generator pressure switch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2008
Resolved 27 May 2008
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 19 May 2008 Resolved
Provide self-closing valve on fuel tank (system) gauge (sight) glass or provide signage to indicate valves to be shut except during gauging check.
Action required: 705 - Other - as specified
Due 3 June 2008
Resolved 27 May 2008
Resolution: Installed signage.
Construction/Loadline › Structures › Machinery Space Opening
Issued 30 April 2008 Resolved
Make exhaust penetrations water tight using an industry and USCG acceptable method.
Due 30 April 2008
Resolved 27 May 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 30 April 2008 Resolved
Clean oil/water from fwd berthing bilge.
Due 30 April 2008
Resolved 27 May 2008
Construction/Loadline › Penetrations › Bottom Plug
Issued 28 April 2008 Resolved
Repair transducer void plate.
Due 28 April 2008
Resolved 30 April 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 28 April 2008 Resolved
Repair portside drain valve and thru hull fitting.
Due 28 April 2008
Resolved 30 April 2008
Construction/Loadline › Hull › Transverse Frame
Issued 28 April 2008 Resolved
Repair fractured welds in forepeak, stbd side at long/deep frame.
Due 28 April 2008
Resolved 19 May 2008
Construction/Loadline › Structures › Air Pipe
Issued 28 April 2008 Resolved
Repair all vents on main deck as needed. Ensure fuel vents have 30x30 mesh flame screens.
Due 28 April 2008
Resolved 19 May 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 April 2008 Resolved
Repair stbd aft fuel fill (replace pedro hose, double hose clamp).
Due 28 April 2008
Resolved 30 April 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 28 April 2008 Resolved
Service E/R fixed CO2 fire system. System was discharged at some point. Provide report as to cause of discharge from servicing technician. Ensure USCG is notified for any future events/failures that effect primary fire, lifesaving, or other vital systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 19 May 2008
Construction/Loadline › Hull › Bottom Plating
Issued 25 April 2007 Resolved
Provide ultrasonic hull gauging report and affect permanent repair to areas of significant pitting identified at aft E/R bottom plate aft of generators (both port & stbd).
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 25 May 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 25 April 2007 Resolved
Replace or clean fuel vent flame screens with 30 x 30 mesh.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 25 May 2007
Communications › Radio Communications › Satellite Communications Capability
Issued 28 March 2007 Resolved
Replace or prove proper operation of installed NAVTEX receiver. Vessel restricted to no more than 100NM from shore until corrected.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 March 2007 Resolved
Ensure proper closure of stbd side E/R ventilation damper.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 28 March 2007 Resolved
Clean excess grease from galley hood grease filters and grease trap, and replace guard for galley hood light fixture.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 March 2007 Resolved
Provide current coast pilot, light list, and tidal current tables.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 April 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 28 March 2007 Resolved
Make bulkhead penetrations watertight for exhaust piping (port and stbd).
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 28 March 2007 Resolved
Replace all expired medications and remove all outdated medication/drugs.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 April 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 28 March 2007 Resolved
Repair/replace broken handle for sea valve in lazarette.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 April 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 March 2007 Resolved
Replace electrical distribution panel on aft bulkhead in E/R.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 March 2007 Resolved
Repair/replace inoperative radar (stbd unit at operating station).
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 March 2007 Resolved
Provide proper connection (junction box) for wire splice above fuel tank.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 April 2007
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 28 March 2007 Resolved
Prove proper operation of inoperative GMDSS hand held radio (1).
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 28 March 2007 Resolved
Submit written CG-2692 form to report recent loss of electrical power.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 April 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 March 2007 Resolved
Conduct and log drills as drills, and not as exercises.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 March 2007 Resolved
Conduct annual exercise as per VSP.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 25 May 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 April 2006 Resolved
Renew forward and aft draft marks, draft marks are missing.
Due 25 April 2006
Resolved 27 April 2006
Resolution: Draft marks are renewed.
Stability › Watertight Integrity › General
Issued 24 April 2006 Resolved
Repair portside hull in the area of the forward breathing area.
Due 25 April 2006
Resolved 27 April 2006
Resolution: 18" by 18" area on the portside hull in the area of the forward breathing area was cropped out due to a pin hole leak. Area was inspected and Dye penetrate test was performed and test was satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 10 April 2006 Resolved
Submit plans for generator replacement.
Due 30 April 2006
Resolved 28 April 2006
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 30 March 2006 Resolved
Provide original International Tonnage Certificate.
Due 14 April 2006
Resolved 4 May 2006
Lifesaving › Rocket Parachute Flares › General
Issued 30 March 2006 Resolved
Provide 12 rocket parachute flares.
Due 14 April 2006
Resolved 10 April 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 March 2006 Resolved
Provide eye wash solution for 1st aid kit.
Due 14 April 2006
Resolved 10 April 2006
Lifesaving › Visual Distress Signals (General) › Storage
Issued 30 March 2006 Resolved
Provide proper mounts for SARTS.
Due 14 April 2006
Resolved 10 April 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 March 2006 Resolved
Replace/provide (1) additional Type 1 child lifejacket
Due 14 April 2006
Resolved 10 April 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 March 2006 Resolved
Repair E/R bilge alarm light.
Due 14 April 2006
Resolved 10 April 2006
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 22 March 2005 Resolved
At next dry-dock, have vessel measured to determine if International Tonnage applies.
Due 22 March 2005
Resolved 16 May 2005
Resolution: Received ABS report that vessel was 185ITC. Cleared above CG-835.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 March 2005 Resolved
Add retro-reflective tape to fwd lifebuoy.
Due 7 April 2005
Resolved 10 May 2005
Resolution: corrected
Communications › Radio Communications › VHF Radiotelephone
Issued 22 March 2005 Resolved
Repair SSB and VHF radios.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2005
Resolved 27 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2005 Resolved
Provide aspirin for 1st aid kit.
Due 7 April 2005
Resolved 27 May 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 March 2004 Resolved
Replace 09 adult PFD's. Carry no more than 31 passengers prior to completion.
Due 30 April 2004
Resolved 30 April 2004
Electrical › Electric Supply System (service)
Issued 11 March 2004 Resolved
Clean the windings on both ship service generators. LEGACY COMPONENT DESC: Generator windings.
Due 30 April 2004
Resolved 30 April 2004
Electrical › Lighting (service)
Issued 2 May 2003 Resolved
provide diffuser for light in cabin berth. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 2 June 2003
Resolved 6 May 2003
Engineering › Fuel Oil Service System
Issued 2 May 2003 Resolved
free emergency F/O cutoff valves and rods. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2003
Resolved 6 May 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 2 May 2003 Resolved
Enable reefer door to be opened from the inside.
Condition: Design Flaw
Due 2 June 2003
Resolved 6 May 2003
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 May 2003 Resolved
Renew drug alcohol swab test kit.
Condition: Improper/Lack of Maintenance
Due 2 June 2003
Resolved 6 May 2003
Communications › Radio Communications
Issued 2 May 2003 Resolved
renew hydrostatic release on EPIRB LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 May 2003 Resolved
Repair exhaust leak in STBD exhaust compartment.
Condition: Improper/Lack of Maintenance
Due 2 June 2003
Resolved 6 May 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 April 2002 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 8 May 2002
Navigation › Piloting/Steering
Issued 29 April 2002 Resolved
Update charts used for operating area. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 8 May 2002
Documentation › Certificates/Documents
Issued 29 April 2002 Resolved
Remove expired Small Passenger Vessel (SPV) sticker.
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 8 May 2002
Accommodation/Occupational Safety
Issued 29 April 2002 Resolved
Clear aft emergency berthing exit (remove carpet over exit).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 8 May 2002
Engineering › Steering Gear System
Issued 29 April 2002 Resolved
Repair starboard steering hydraulic ram (leaking during operational check of steering system). LEGACY COMPONENT DESC: Actuator
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 28 May 2002
Documentation
Issued 28 June 2001 Resolved
Post COI in plain view of passengers.
Condition: Unknown
Due 5 July 2001
Resolved 5 February 2002
Resolution: Entered in error during MSIS/MISLE change-over.
Lifesaving
Issued 28 June 2001 Resolved
Provide proper separation of childs and adults PFDs.
Condition: Unknown
Due 5 July 2001
Resolved 5 February 2002
Resolution: Entered in error during MISLE/MSIS change-over.
Navigation
Issued 28 June 2001 Resolved
Provide proof of repair of steering system.
Condition: Unknown
Due 5 July 2001
Resolved 5 February 2002
Resolution: Entered in error during MISLE/MSIS change-over.
Construction/Loadline
Issued 28 June 2001 Resolved
Repair bilge alarm in lazarette.
Condition: Unknown
Due 5 July 2001
Resolved 5 February 2002
Resolution: Entered in error during MISLE?MSIS change-over.
Engineering
Issued 20 April 2001 Resolved
Remove and repair props for Coast Guard inspection.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 20 April 2001 Resolved
Provide damage control kit for PVC piping.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 20 April 2001 Resolved
Provide metallic piping traversing through water tight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 8 February 2002
Resolution: Vessel meets non-metallic piping installation requirements of 46 Code of Federal Regulations 182.700.
Engineering
Issued 20 April 2001 Resolved
Fix fuel leak from fuel manifold forward bulkhead engine room.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 20 April 2001 Resolved
Repair stern damage (port & starboard side) above the water line.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 20 April 2001 Resolved
Clean fuel from bilge under starboard engine.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 20 April 2001 Resolved
Repair bottom paint as necessary.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Engineering
Issued 20 April 2001 Resolved
Replace port & starboard forward generator seals.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 25 May 2000 Resolved
Install high level bilge alarm in forepeak, prove proper operation to CG inspector both audio and visual.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Construction/Loadline
Issued 25 May 2000 Resolved
Install high level bilge alarm in aft berthing bilge. Prove proper operation to CG inspector both audio and visual.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Electrical
Issued 3 May 2000 Resolved
Renew SARTS battery.
Condition: Unknown
Due 4 May 2000
Resolved 8 May 2000
Navigation
Issued 3 May 2000 Resolved
Update publications over 3 yrs old re: Coast Pilot [name withheld], CFRs etc.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000 Resolved
Update charts.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 3 May 2000 Resolved
Renew broken deck plate in E/R.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 3 May 2000 Resolved
Remove fuel from sonar compartment, find and fix leak.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 3 May 2000 Resolved
Master needs current CPR 1st aid as per ISM.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000 Resolved
Familiarize with publications.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Documentation
Issued 3 May 2000 Resolved
Update ISM to 5 yr COI.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 3 May 2000 Resolved
Repair rudder angle indicator.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 3 May 2000 Resolved
Acquire required number of SOLAS flares.
Condition: Unknown
Due 4 May 2000
Resolved 8 May 2000
Accommodation/Occupational Safety
Issued 3 May 2000 Resolved
Install galley hood
Condition: Unknown
Due 4 May 2000
Resolved 8 May 2000
Construction/Loadline
Issued 3 May 2000 Resolved
Fix inoperable bbilge alarm in lazarette.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Fire Fighting
Issued 8 April 1999 Resolved
Correct improper installation of fixed fire system.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Accommodation/Occupational Safety
Issued 8 April 1999 Resolved
Install guard on A/C compressor aft engine room, port side.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Engineering
Issued 8 April 1999 Resolved
Renew as required all fuel vent fittings.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Navigation
Issued 19 May 1997 Resolved
Show proper operation of rudder angle indicator at both steering stations.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Fire Fighting
Issued 19 May 1997 Resolved
Properly mark remote pull for fixed fire extinguishing system.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 19 May 1997 Resolved
Remove excessive water in sonar bilge area.
Condition: Unknown
Due 23 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 19 May 1997 Resolved
Properly remove excessive bilge slops from bilges.
Condition: Unknown
Due 23 May 1997
Resolved 27 May 1997
Electrical
Issued 4 May 1995 Resolved
PROVIDE EMERGENCY LIGHTS IN THE OVERNIGHT ACCOMMODATION SPACES BY PROVIDINGOPENING ON EACH DOORS TO PERMIT EMERGENCY LIGHTS TO LIGHT THE ESCAPE ROUTE OUT OF EACH STATEROOMS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 4 May 1995 Resolved
MARK FIRE AXE WITH VESSEL NAME.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Engineering
Issued 4 May 1995 Resolved
REMOVE EXCESSIVE LENGTH OF FLEXIBLE FUEL LINE CONNECTED TO PORT ENGINE.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Electrical
Issued 4 May 1995 Resolved
POWER PANELS IN ENGINE ROOM NOT MARKED TO INDICATE EACH CIRCUIT USE.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Documentation
Issued 4 May 1995 Resolved
VALID ABS LOADLINE CERTIFICATE NOT HELD ONBOARD.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Electrical
Issued 15 April 1993 Resolved
PROVIDE A COVER FOR THE JUNCTION BOX LOCATED ON THE AFT BULKHEAD OF THE FOREPEAK COMPARTMENT.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 15 April 1993 Resolved
PROVIDE METAL CABLE SUPPORTS AS PER IEEE STANDARD 45, 20.5, EVERY 24 INCHESFOR WIRING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 15 April 1993 Resolved
REPLACE TWIST CONNECTORS WITH PERMANENT CONNECTORS FOR WIRING LOCATED ON AFT BULKHEAD OF FOREPEAK COMPARTMENT.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 15 April 1993 Resolved
REPLACE TWIST CONNECTORS WITH PERMANENT CONNECTORS FOR WIRING LOCATED BELOWSTATEROOM "N" IN WAY OF FUEL TANKTOP (BILGE ALARM).
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Construction/Loadline
Issued 15 April 1993 Resolved
MAKE PERMANENT REPAIRS TO FRAME 2, STARBOARD SIDE, IN WAY OF PREVIOUS REPAIR.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Navigation
Issued 8 May 1991 Resolved
PROVIDE CURRENT TABLE AND LIGHT LIST FOR YEAR 1991.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Construction/Loadline
Issued 8 May 1991 Resolved
PROPERLY REPAIR THE STARBOARD VENTILATION DAMPER IN THE ENGINE ROOM.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Documentation
Issued 8 May 1991 Resolved
PROVIDE AN ANNUAL SURVEY CERTIFICATE BY FCC ON THE RADIO TELEPHONE _x001C_ INSTALLATION AND SOLAS EXEMPTION.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Lifesaving
Issued 8 May 1991 Resolved
PROPERLY STOW THE LIFERAFTS UPON RECEIPT FROM THE SERVICING FACILITY AND _x001C_ PRIOR TO DEPARTURE AND OPERATION WITH PASSENGERS.
Condition: Unknown
Due 8 May 1991
Resolved 8 May 1991
Electrical
Issued 15 April 1991 Resolved
PROVIDE PROPER PLASTIC OR LEAD LINED TRAY FOR THE BATTERY STOWAGE BOXES_x001C_ LOCATED ON THE MAIN DECK, AFT OF THE DECK HOUSE.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Unknown
Issued 8 May 1989 Resolved
REPAIR LEAKING EXHAUST PIPE TO STARBOARD SERVICE GENERATOR.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Navigation
Issued 8 May 1989 Resolved
PROVIDE THREE(3) BLACK BALL DAY SHAPES.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Navigation
Issued 8 May 1989 Resolved
PROVIDE NEW BATTERY FOR THE EPIRB.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Unknown
Issued 8 May 1989 Resolved
HYDROTEST AIR HORN RECEIVER AT 1 1/4 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Engineering
Issued 31 May 1988 Resolved
REPAIR SUSPECTED MALFUNCTION TO PNEUMATICALLY OPERATED POWER TRANSMISSION ON MAIN PROPULSION DIESEL PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Construction/Loadline
Issued 31 May 1988 Resolved
MAKE PERMANENT REPAIRS TO HOLE APPROXIMATELY 10FT LONG, 6FT WIDE, 4-5FT ABOVE THE LOAD WATERLINE JUST FORWARD OF COLLISION BULKHEAD IN WAY OF STAR-BOARD SIDE SHELL PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Navigation
Issued 12 May 1988 Resolved
MAKE AIR RECEIVER READY FOR INTERNAL INSPECTION.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Documentation
Issued 12 May 1988 Resolved
PROVIDE FCC CERTIFICATION.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Engineering
Issued 12 May 1988 Resolved
INSTALL AIR DUCT IN ENGINE ROOM.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988

Casualty record · 12

3 December 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1714323
3 October 2003Routine · role: Involved in a Marine Casualty · 1 dead · activity 1920757
19 July 2004Routine · role: Involved in a Marine Casualty · 1 dead · activity 2148081
15 August 2006Routine · role: Involved in a Marine Casualty · activity 2777302
14 March 2007Routine · role: Involved in a Marine Casualty · activity 3107475
14 November 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3104687
25 April 2008Routine · role: Involved in a Marine Casualty · activity 3235216
1 February 2009Routine · role: Involved in a Marine Casualty · activity 3417583
22 May 2012Routine · role: Involved in a Marine Casualty · activity 4321741
6 July 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4370127
27 August 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4423907
20 June 2026Routine · role: Involved in a Marine Casualty · activity 8410622
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.