Records from 2002 to 2026. Most recent: inspection, 20 June 2026.
Inspection history · 42
20 June 2026
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8410622
10 June 2026
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8367444
2 April 2026
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8309725
22 January 2026
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8300379
10 June 2025
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8135693
2 April 2025
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8103635
28 October 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8026751
12 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7937196
29 May 2024
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7923208
2 April 2024
Internal Structural Exam · Hull Examination · Inclining Experiment
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7889063
18 October 2023
Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7810857
6 September 2023
Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7787948
24 May 2023
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7690320
10 April 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7670226
3 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662119
6 December 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7605281
17 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7578898
30 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7569558
30 September 2022
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7624105
28 May 2022
Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7469272
25 May 2022
MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7458156
25 March 2022
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7418567
23 March 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504150
20 January 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7383353
23 September 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319102
19 May 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188241
8 April 2021
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7172165
17 June 2020
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6974917
7 April 2020
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6955386
4 February 2020
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903284
6 November 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6849555
19 June 2019
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6717545
18 March 2019
Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6660391
27 September 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6550172
25 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548009
23 May 2018
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6414487
9 April 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6387883
24 May 2017
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6148358
15 May 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6163737
5 April 2017
Administrative Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6118240
23 May 2016
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5884242
5 April 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5847581
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 May 2024
Resolved
Vessel does not have current stability letter.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2024
Resolution: Vessel was issued a new stability letter by MSC.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 May 2024
Resolved
Vessel EPIRB hydro expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2024
Resolution: Observed new EPIRB's hyro-static release
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2024
Resolved
Vessel Safety Radio certificate expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2024
Resolved 17 June 2024
Resolution: observed FCC certificate
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 May 2024
Resolved
Vessel master could not prove LRIT was transmitting position.
Condition: Invalid
Action required: 702 - Prior to embarking on international voyage
Resolved 17 June 2024
Resolution: observed LRIT transmission
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 29 May 2024
Resolved
Vessel SSB non operational.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 17 June 2024
Resolution: observed operational test of MF/HF radio
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2022
Resolved
On May 25, 2022, an 835 was issued stating
"Main Salon rod reel line spool machine unit has multiple cable splices in power cord. Reel spool machine unit power cord must be of an approved type per its manufacturer. Must replace cable or remove unit."
On September 30, 2022 the vessel was found to have the spool machine back on board and in service. Equipment must be removed prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2022
Resolution: SSD MI's verified the equipment was no longer onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 September 2022
Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit.
Stateroom H was found to have a smoke detector without a battery after attempting to test it. Vessel must replace battery and ensure unit is operational in addition to testing and ensuring proper operation of all smoke detectors onboard prior to carriage of passengers. Licensed Mariner must provide statement in writing, signed with their MMC Reference # to the full operability and completion of satisfactory testing on all smoke detectors onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2022
Resolution: Vessel previded attestation that all vessels smoke detectors were tested and operational, in addition Mi's conducted a spot check and verified the operation of two random smoke detectors.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 September 2022
Resolved
AIS must be maintained in effective operating condition, which includes the continual operation of AIS and its associated devices at all times while the vessel is underway or at anchor, and, if moored at least 15 minutes prior to getting underway.
The AIS installed on board was not transmitting and has not been transmitting since January 2, 2022. The vessels AIS was found in the off position at the time of the in service inspection but when it was turned on the AIS was still not transmitting. Vessel must ensure AIS is operating as designed. The vessel must rectify prior to the carriage of passengers after October 8, 2022.
Action required: 705 - Other - as specified
Resolved 8 October 2022
Resolution: Verified through JHOC and onscene that all systems are working. DEM
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 30 September 2022
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. The escape hatch from aft passenger berthing was blocked by an anti slip carpet in a manner preventing the usage of the escape hatch.
Action required: 30 - Ship detained
Resolved 30 September 2022
Resolution: Vessel removed the rug that was covering the escape hatches from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2022
Resolved
All vessels on an Oceans Route are required to carry twelve (12) distress flares. Vessel only had nine (9) rocket parachute flares on board at time of inspection. Vessel operator must provide three (3) additional rocket parachute flares prior to sailing on an oceans route.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: POC Provided proof of the appropriate number of flares.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022
Resolved
Topside deck freezer units (3) power cord spliced. Power cord must be of an approved type per its manufacturer. Must replace to satisfaction of CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Corrected. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022
Resolved
Main Salon rod reel line spool machine unit has multiple cable splices in power cord. Reel spool machine unit power cord must be of an approved type per its manufacturer. Must replace cable or remove unit.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Unit unplugged and removed from vessel. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022
Resolved
Port side FWD PAX accommodation room closet; electrical cable has multiple splices; Replace cable.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2022
Resolution: Replaced electrical cable. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022
Resolved
Fore peak void; Overhead electrical junction box not properly mounted. Must repair to the satisfaction of the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2022
Resolution: Corrected. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022
Resolved
Engine room: following electrical panels not properly sealed: FWD BHD outboard STBD side electrical panel,
FWD BHD outboard Port side electrical panel, AFT BHD
Outboard Port side electrical panel, SWBD panel light indicator covers (3) missing. Must repair to the satisfaction the CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 June 2022
Resolution: Corrected; received pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 May 2021
Resolved
While conducting operational tests of the steering gear, the stbd rudder was making an unusual noise. Upon further investigation it was discovered the upper support bearing was wasted away and failed. Replace bearing and prove proper operation of stbd rudder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: Vessel's crew replaced the upper rudder bearing, conducted steering test at the pier, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2021
Resolved
While conducting fire main / fire hose pressure test, the stbd main deck fire hose ruptured. Replace fire hose with in-kind 1-1/2” UL 19 approved type.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2021
Resolution: Vessel's crew repaired fire hose, hoses tested sat under working pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2021
Resolved
While Inspecting life saving appliances discovered 01 Ring Life Buoy deteriorating due to excessive sun damage. Provide vessel with new 24 in. SOLAS approved Ring Life Buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 21 May 2021
Resolution: Vessel rep replaced life ring with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 6 February 2020
Resolved 4 February 2020
Resolution: Vessel submitted A/C one-line drawing, SSD reviewed drawing and conducted accuracy spot check on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 November 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2019
Resolution: Conducted training
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019
Resolved
Electrical equipment on a vessel must be installed to protect persons from electrical hazards. Remove stray cable in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 15 November 2019
Resolution: Dead ended cable was removed from galley.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2019
Resolved
Repair leaking shaft seal on center shaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: New dripless fitting installed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 June 2019
Resolved
Replace expired EPIRB HRU.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: New HRU installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 June 2019
Resolved
Replace expired First Aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: New first aid kit on board.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 June 2019
Resolved
Store O2/Acetylene cylinders on open deck (or remove).
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2019
Resolved 21 June 2019
Resolution: Gas cylinders removed from vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
Cover open slots within circuit breaker panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 10 July 2019
Resolution: Pictures used to clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 June 2019
Resolved
Replace inoperable oil pressure gauge on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 10 July 2019
Resolution: Pictures used to clear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2019
Resolved
Replace missing cover for electrical panel under helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 10 July 2019
Resolution: Pictures used to clear.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 June 2019
Resolved
Repair cracked longitudinal frame in forepeak stbd side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 21 June 2019
Resolution: Repaired
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 June 2019
Resolved
Correct station bills with proper crew duties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 21 June 2019
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Port side MDE fuel leak on main fuel return line. Make proper repairs and prove proper operation to attending MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2018
Resolved 27 September 2018
Resolution: Attending MI's operational tested MDE. No leaking present from saudered piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Stbd side MDE fuel injection line leaking at header #2. Repair and prove proper operation to attending MI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2018
Resolved 27 September 2018
Resolution: MI's witnessed engineer identify loose bolt on individual fuel return lines. Bolt tigtened. Leak stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2018
Resolved
Stbd generator has improper repairs to expansion tank freeze plugs (belzona). Make repairs and prove proper operation to attending MI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2018
Resolved 27 September 2018
Resolution: Freeze plugs installed. Generator operationally tested under load.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Center MDE oil leaking off port side. Make repairs and prove proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: Replaced fuel pump, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Center MDE improper repairs to jacket water freeze plug. Make repairs and prove proper operation to attending MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: Freeze plug replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2018
Resolved
Fiberglass observed at MDE shaft logs. Continuously inspect and make permanent repairs at dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 21 June 2019
Resolution: Port & Stbd shaft logs renewed. Center authorized one additional year of use. Special note added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Port MDE leak on #2 cylinder fuel injection line at flared fitting. Make repairs and prove proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: Replaced fuel line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 September 2018
Resolved
Stbd side fuel day tank sight glass is leaking with temporary repair. Make repairs and prove proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2018
Resolved 29 October 2018
Resolution: LTI repaired, tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V), ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS
Fire Fighting › Means of Escape › Doorways
Issued 23 May 2018
Resolved
Provide means of escape from reefer.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 23 May 2018
Resolved
Fill out emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2018
Resolved
Provide current charts and navigation publications.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 13 August 2018
Resolution: Charts onboard
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 23 May 2018
Resolved
Replace smoke detector in fwd bunkroom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Fire Fighting › Firemans Outfit › Axe
Issued 23 May 2018
Resolved
Provide a fire axe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2018
Resolved 31 July 2018
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 24 May 2017
Resolved
Provide LRIT conformance test results prior to sailing international.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 June 2017
Communications › Radio Communications › EPIRB
Issued 23 May 2016
Resolved
Prior to operating greater than 3 nm from shore, provide valid EPIRB
Action required: 705 - Other - as specified
Resolved 27 May 2016
Resolution: Attended vessel and verified validity of EPIRB
Communications › Radio Communications › EPIRB
Issued 23 May 2016
Resolved
Prior to operating greater than 3 nm from shore, stow EPIRB in float free location.
Action required: 705 - Other - as specified
Resolved 27 May 2016
Resolution: Attended vessel and verified float free stowage of EPIRB
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2016
Resolved
Provide proper plugs for fuel filter bowls located on stbd side engine room.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified proper metallic plugs fitted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 May 2016
Resolved
Properly terminate all splices under nav console
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified proper termination of splice.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2016
Resolved
Provide burn gel
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified burn gel on board.
Engineering › Fuel Oil Service System › Valve
Issued 23 May 2016
Resolved
Provide emergency fuel shutoff decal
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 27 May 2016
Resolution: Attended vessel and verified Emergency Fuel Shut off now labeled.