CONSTITUTION

CONSTITUTION is a 1992 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in August 2026, along with 87 deficiencies, 1 operational control and 6 casualty investigations between 2012 and 2022.

Records from 2012 to 2026. Most recent: inspection, 18 August 2026.

Built
1992
Last inspected
18 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 August 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5813
371674
Flag
UNITED STATES
Maury page id
psix-371674

Documentation record

Registered dimensions (L × B × D)73.0 ft × 20.5 ft × 8.6 ft
Registered tonnagegross 86 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SHANNON DANN Towing Vessel · MISLE 108694 · 17 May 2016 · activity 5879927

Inspection history · 29

18 August 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8467203
27 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8325415
24 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8118409
18 March 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095560
13 May 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7895609
3 August 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853644
11 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7685851
26 January 2023 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7619290
7 August 2022 Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7527069
7 August 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7531284
13 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7449904
27 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7183973
1 February 2021 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134011
5 October 2020 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071941
5 October 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7086060
13 April 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6939227
23 March 2020 Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930583
3 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6827664
14 September 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6856423
1 July 2019 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6732770
1 October 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6560021
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539818
25 July 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6490737
25 June 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6450307
23 May 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6421491
22 June 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6183201
12 October 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6020879
6 July 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5931948
17 May 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5879927

Deficiency record · 87

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 April 2026 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Restore guards to cover rotating machinery in engine room. 46 CFR 177.960
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2026
Resolution: Pics of guards received.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 27 April 2026 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel had multiple new employees who had not yet taken a pre employment test nor were they enrolled in a random testing program. All employees must have a negative drug test before being employed in a safety sensitive position. 46 CFR 16.210
Action required: 705 - Other - as specified
Resolved 3 June 2026
Resolution: Rcvd pictures of negative tests for crewmembers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2025 Resolved
Vessel's port main engine raycor fuel filter was identified by vessel owner to be leaking. Repair or replace fuel filter.
Action required: 705 - Other - as specified
Resolved 2 June 2025
Resolution: Received photo of corrected def.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 April 2025 Resolved
Conduct underway man overboard drills after repairs to port engine raycor filter.
Action required: 705 - Other - as specified
Resolved 2 June 2025
Resolution: Received video of underway drills.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2025 Resolved
Vessel was discovered to have a missed for its drydock exam. To maintain a valid COI, the vessel must complete its drydock exam every 2 years before date stated on COI. Vessel is restricted from carrying passengers for hire until it completes a satisfactory Drydock exam.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2025
Resolution: Hull exam completed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 March 2025 Resolved
Vessel completed dry dock and has not completed IFR / Egress drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: Conducted egress drills. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 March 2025 Resolved
Repair or replace stbd main engine sea valve, valve would not close all the way.
Action required: 705 - Other - as specified
Resolved 21 March 2025
Resolution: Valve was cleaned and lubricated, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 March 2025 Resolved
Small area of fiberglass de-lamination was identified on the port side / forward hull. Remove failed fiberglass and submit repair plan.
Action required: 705 - Other - as specified
Resolved 21 March 2025
Resolution: Failed layer of glass was removed to solid glass and repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2024 Resolved
Provide all three life ring buoys with new retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: retro-reflective tape was provided for all life rings.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 May 2024 Resolved
Seal forward engine room bulkhead (port and stbd) with fire proof caulking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: forward bulkhead was sealed with fire rated sealant.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024 Resolved
Provide 12V wheelhouse panel with breaker blank to fill the not used opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: Panel blank was provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 August 2023 Resolved
As stated in letter dated September 14, 2023, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not meet requirements and is restricted from carrying overnight passengers in accommodation spaces. National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b)
Action required: 705 - Other - as specified
Resolved 4 April 2025
Resolution: Witness egress drills. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2023 Resolved
Both main engine exhaust found to be installed without protective insulation on areas that exceed 150 degrees. Install protective insulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 7 June 2023
Resolution: Installed insulation on turbos and exhaust piping.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2023 Resolved
The owner/operator shall instruct crew members on primary duties in cases of emergencies at least once every three months and log. Last logged drill was November, 2022. Must conduct emergency exercise/briefing with crew members in accordance with station bill prior to getting underway with passengers and log.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2023
Resolution: Vessel POC performed and logged drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2022 Resolved
Starboard Shaft sheared off. Vessel is required to make repairs prior to the carriage of passengers / cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2022
Resolved 12 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 May 2022 Resolved
Vessel radio safety certificate found to be expired. Provide valid radio safety certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Obtained new Safety Certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 May 2022 Resolved
Vessel VHF DSC radio found to be programmed without MMSI informaion. Program radio to include MMSI
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Programmed MMSI and GPS information.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 May 2022 Resolved
Multiple water pumps in the bilge found to be not secured. Secure pumps to prevent movement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2022
Resolution: Secured pumps from movement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2022 Resolved
Fuel shutoff valves found to be missing label. Label valve IAW CFR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Installed label for fuel shutoff valves.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2022 Resolved
Open wire found in pump room. Terminate wire IAW CFR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Terminated wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2022 Resolved
Twist on wire connectors are not permitted, remove and replace noted connector in engine room and on top of operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Replaced connector with approved type.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 April 2021 Resolved
The battery on the vessel's EPIRB is expired. Replace the EPIRB battery if authorized by the manufacturer or provide a new Category 1 406 MHz EPIRB that is registered with NOAA. The vessel is restricted to no more than 3 NM from shore until this deficiency is resolved.
Action required: 705 - Other - as specified
Resolved 9 June 2021
Resolution: Operator acquired a new EPIRB which had a valid battery and registration. Witnessed a satifcactory test of the EPIRB.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 April 2021 Resolved
Provide lazarette hatch with captive chain fastened securely to the hatch frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Vessel provided hatch with a cord to secure the hatch to the hatch frame, and was found to be sufficient.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
Remove dead ended electrical cable found in pump room void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Visually identified that the dead-end wire had been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
Remove wire nuts from speaker cable behind helm and properly connect with pressure connectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Visually identified that the wire nuts had been swapped for pressure connectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 April 2021 Resolved
Provide stbd generator fuel lines with manufacture provided securing bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Visually identified new fuel line securing brackets on starboard generator, which are identical to the ones on the port generator.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2021 Resolved
Properly mount electric griddle in galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Crew screwed the upper section of the griddle's splash shielding to the B15 bulkhead to secure the griddle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2021 Resolved
Provide approved type of bracket for 02 portable fire extinguishers: 1) galley & 2) aft bunk room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 10 June 2021
Resolution: Vessel acquired 02 new fire extinguisher brackets appropriate for each extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 April 2021 Resolved
Provide accurate instructions for the release of CO2 system, to include “pull pin” prior to pulling lever/handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Owner had a new sign created and posted IVO the controls, which clearing instructed how to operate the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020 Resolved
VESSEL PORT SHAFT REPORTED SHEARED WHILE UNDERWAY AT SEA. MAKE AREAS IWO SHEARED SHAFT AVAILABLE FOR INSPECTION BY MARINE INSPECTOR. PROVIDE REPAIR PROPOSAL TO ATTENDING MARINE INSPECTOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2020
Resolved 9 October 2020
Resolution: Inspected by attending MI's.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 April 2020 Resolved
Port main fuel shut off could not shut off the fuel supply. Repair the port main fuel shut off.6930583
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2020 Resolved
Repair/replace the identified worn life buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 April 2020 Resolved
Provide FCC Marine Radio Operator Permit for all required licensed crew members. Vessel may not operate more than 1000 feet from shore until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 25 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2020 Resolved
Six (05) flares were not of an approved type. Provide five (05) new flares of either the orange smoke, red hand, or red parachute type that are USCG 160.021 approved. Vessel is restricted to a "Lakes, Bays, and Sounds" route until this deficiency is corrected. 46 CFR 180.68.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 August 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2020 Resolved
Provide fire fighting equipment servicing document attesting to the correct operating of the fixed fire-fighting system shut-downs and override following generator replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2020
Resolved 25 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 April 2020 Resolved
Post COI under glass on board the vessel as per 46 CFR 176.302.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 21 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2019 Resolved
Provide additional ladder rung near top of forward emergency exit. 46 CFR 177.15-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 13 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019 Resolved
Electrical equipment must be installed and maintained to protect passengers, crew and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Correct the following: (1) Remove or properly terminate (in j-box) dead-end wires found in crew bunk (2) Install spare cover on opening in distribution panel in wheelhouse. (3) Update labels in distribution panel in galley. 46 CFR 177.05-1(a)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 13 April 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2019 Resolved
Replace battery in smoke detector in passenger cabin on main deck. Install smoke detector at forward end of passenger accommodation below deck and in crew cabin (if door is installed). 46 CFR 181.450
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2019 Resolved
Mark fwd emergency escape on both sides w/ "EMERGENCY EXIT - KEEP CLEAR" in letters > 2". 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 25 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2019 Resolved
Provide and log training to all crew regarding use of fire-fighting equipment, engine room CO2 pull station, ventilation closures. 46 CFR 185.524
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Received email with picture of updated log book.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2019 Resolved
Provide current active employee list from consortium with all crew members. 46 CFR 16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 13 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019 Resolved
Remove and replace welding cables with approved battery cables.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019 Resolved
Properly mount fuel transfer pump in machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019 Resolved
Replace defective fuel hoses on starboard side generator and port side main engine. Install guard on day tank sight glass.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 July 2019 Resolved
Replace defective pressure switch for main engine shutdown.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2019
Resolution: Replaced switch.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 July 2019 Resolved
Remove obstructions to fuel shutoff valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 July 2019 Resolved
Replace port and starboard rudder carrier bearings, prove proper operation of steering system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 9 July 2019
Resolution: Replaced, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
CLSN: Vsl is broadcasting Invalid Call Sign, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: No longer in VIVS
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2018 Resolved
Vessel is restricted to carriage of 33 total persons until additional life raft/IBA is provided
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 June 2018 Resolved
Provide permanent fire dampers for both Port and STBD engine room vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2018 Resolved
No sail CG-835: Prove proper operation of the fire pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2018
Resolved 27 June 2018
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 June 2018 Resolved
Conduct underway emergency drills (Fire and Man overboard) in the presence of a CG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2018
Resolved 27 June 2018
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 June 2018 Resolved
Restricted route: Vessel may not operate more than 20NM from the closest point of land until a HF/MF radio with DSC is provided, properly installed, and certified on the vessels safety radiotelephony certificate.
Action required: 705 - Other - as specified
Due 25 July 2018
Resolved 27 June 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2018 Resolved
Make entire Drug and Alcohol program available for inspection
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 June 2018 Resolved
Galley range hood vent ducting needs a thorough cleaning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 1 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2018 Resolved
Provide adequate pulley/belt safety guards for the STBD generator and port Main propulsion engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 1 July 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 June 2018 Resolved
Provide valid medical cards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 June 2018 Resolved
Prove operation of bunk room bilge alarm visual signal (light.)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2018 Resolved
Properly install two main engine 24vlt breakers IVO forward STBD main engine overhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2018 Resolved
Engine room: Provide Junction box cover for 120vlt wiring
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 June 2017 Resolved
Provide battery box lid at helm.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Lid installed.
Navigation › Piloting/Steering › Marine Charts
Issued 22 June 2017 Resolved
Provide current charts, coast pilot, tide tables, currents.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Publications provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2017 Resolved
Provide wire nuts for dead end wires under helm.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Wire nuts installed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 22 June 2017 Resolved
Secure forepeak hatch to rope/leash/line.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Forepeak secured.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 June 2017 Resolved
Provide smoke detector for upper stateroom.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Fire detector installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 June 2017 Resolved
Provide light and light cover in pump room.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Light and cover installed.
Engineering › Fuel Oil Service System › Pump
Issued 22 June 2017 Resolved
Mount and secure fuel pump.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Pump mounted.
Communications › Radio Communications › EPIRB
Issued 22 June 2017 Resolved
Provide NOAA EPIRB paper work.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: EPIRB documentaion provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2017 Resolved
Provide first aid kit.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: First aid kit provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 June 2017 Resolved
Post COI so passengers can view.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: COI posted in public view.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 June 2017 Resolved
Provide drug testing paperwork.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Drug testing documentation provided.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 June 2017 Resolved
Provide 65 lifejackets to meet COI requirement. 23 June 2017 - Provide 12 lifejackets to meet COI. 28 June 2017 - 12 life jackets provided to meet COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Resolution: All lifejackets on board vessel. Meet requirements of COI.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 22 June 2017 Resolved
Secure 04 junction boxes on top of pilot house.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Junction boxes secured.
Fire Fighting › Fire Hoses › Condition
Issued 22 June 2017 Resolved
Provide new port side firehose. Firehose wasted.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: New firehose provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 22 June 2017 Resolved
Lift CO2 tanks 2 inches off of deck.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Tanks lifted 2 inches off of the deck.
Fire Fighting › Fire Hoses › Connections
Issued 22 June 2017 Resolved
Mount fire hoses so they are attached to the fire hydrant at all times.
Action required: 705 - Other - as specified
Due 23 July 2017
Resolved 28 June 2017
Resolution: Fire hoses mounted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 July 2016 Resolved
Provide EAP substance abuse hotline number posted
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 6 July 2016
Resolution: Properly posted EAP substance abuse hotline number
Communications › Alarms/Indicators › High Water Alarm
Issued 6 July 2016 Resolved
Prove proper operation of the high water level alarm for the bunk roo (prior to carrying passenger)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2016
Resolution: The nuetral wire was re-attached and tested.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 July 2016 Resolved
Properly secure upper deck rail system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Deck rail now properly secured
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 July 2016 Resolved
Label forward emergency escape hatch on both sides
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Escape hatch now labeled.
Stability › Watertight Integrity › General
Issued 6 July 2016 Resolved
Make forepeak hatch watertight
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Fore peak hatch is now water tight
Electrical › Lighting (service) › Switch
Issued 6 July 2016 Resolved
Install light switch cover in bunk room overhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Light switch cover is now installed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 July 2016 Resolved
Install guards on maintenance machinery pulleys
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Guards are now in place
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 July 2016 Resolved
install covers on 110 panel and junction box in pump room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Covers are now installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 July 2016 Resolved
Modify battery box cover in engine room to fit over terminals
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Battery box was modified.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 6 July 2016 Resolved
Provide 8 adults sized life jackets
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 July 2016
Resolution: Added 8 adult sized life jackets

Casualty record · 6

22 May 2012Routine · role: Involved in a Marine Casualty · activity 4321741
17 May 2016Major Marine Casualty · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · activity 5879927
1 October 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6560021
14 September 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6856423
5 October 2020Routine · role: Involved in a Marine Casualty · activity 7086060
7 August 2022Routine · role: Involved in a Marine Casualty · activity 7531284
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.