CONSTITUTION

CONSTITUTION is a 1992 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1992, most recently in August 2026, along with 276 deficiencies, 1 operational control and 6 casualty investigations between 2012 and 2022.

Records from 1992 to 2026. Most recent: inspection, 18 August 2026.

Built
1992
Last inspected
18 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH5813
371674
Flag
UNITED STATES
338299000, 367075060, 367148630 (licence lapsed)
Maury page id
psix-371674

Inspections, by type

…with no type recorded18
Years with a record 33 calendar years (1992–2026)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)73.0 ft × 20.5 ft × 8.6 ft
Registered tonnagegross 86 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1992
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH5813MMSI 338299000 · expired · compulsorily equipped · granted 10 July 2014, cancelled 14 September 2024
WDD4734MMSI 367148630 · expired · compulsorily equipped · granted 2 November 2006, cancelled 7 January 2017
WDC7678MMSI 367075060 · expired · compulsorily equipped · granted 5 November 2005, cancelled 9 January 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SHANNON DANN Towing Vessel · MISLE 108694 · 17 May 2016 · activity 5879927RED ROOSTER III Passenger (Inspected) · MISLE 54910 · 22 May 2012 · activity 4321741

Inspection history · 88

18 August 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8467203
27 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8325415
24 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8118409
18 March 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095560
13 May 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7895609
3 August 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853644
11 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7685851
26 January 2023 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7619290
7 August 2022 Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7527069
7 August 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7531284
13 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7449904
27 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7183973
1 February 2021 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134011
5 October 2020 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071941
5 October 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7086060
13 April 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6939227
23 March 2020 Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930583
3 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6827664
14 September 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6856423
1 July 2019 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6732770
1 October 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6560021
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539818
25 July 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6490737
25 June 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6450307
23 May 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6421491
22 June 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6183201
12 October 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6020879
6 July 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5931948
17 May 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5879927
11 June 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4886013
9 June 2014 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4884329
22 May 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4321741
2 December 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4200502
1 December 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4199441
24 September 2010 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3810243
17 March 2010 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3697457
16 July 2009 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3535551
7 November 2008 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3358980
17 October 2008 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3334735
16 April 2008 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3169083
6 December 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3110543
11 October 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3059689
13 February 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2871367
1 February 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2875371
24 October 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2804754
11 May 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2638187
13 March 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2586798
28 October 2005 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2513183
14 June 2004 COI Inspection · Deficiency Check · Inclining Experiment
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2091342
26 May 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2065881
2 August 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1867602
2 June 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1807749
26 May 2003 Deadweight Survey · Inclining Experiment · Construction Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1804996
22 May 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1799000
18 February 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1737022
16 December 2002 COI Inspection · Plan Review "T" Boat
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718598
26 November 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1711383
12 November 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1707204
21 May 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1618123
31 July 2001 Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070719
12 July 2001 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1069483
5 July 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1068002
9 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 37097
9 June 2001 Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1066189
28 August 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 17274
4 May 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049588
3 August 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 778042
1 June 1999 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1192518
27 October 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 803229
29 July 1998 Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1364821
30 June 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1128065
29 July 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 781787
13 July 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 182653
14 November 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 666685
4 September 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 213834
8 August 1996 Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088443
25 October 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 874294
1 August 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880822
16 February 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 842877
7 January 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1171480
3 August 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175407
18 February 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165130
9 August 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147946
2 November 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249998
7 August 1992 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942994
5 August 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 44898
5 August 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 70461
15 June 1992 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1264608

Deficiency record · 276

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 April 2026 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Restore guards to cover rotating machinery in engine room. 46 CFR 177.960
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2026
Resolution: Pics of guards received.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 27 April 2026 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel had multiple new employees who had not yet taken a pre employment test nor were they enrolled in a random testing program. All employees must have a negative drug test before being employed in a safety sensitive position. 46 CFR 16.210
Action required: 705 - Other - as specified
Resolved 3 June 2026
Resolution: Rcvd pictures of negative tests for crewmembers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 April 2025 Resolved
Vessel's port main engine raycor fuel filter was identified by vessel owner to be leaking. Repair or replace fuel filter.
Action required: 705 - Other - as specified
Resolved 2 June 2025
Resolution: Received photo of corrected def.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 April 2025 Resolved
Conduct underway man overboard drills after repairs to port engine raycor filter.
Action required: 705 - Other - as specified
Resolved 2 June 2025
Resolution: Received video of underway drills.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 March 2025 Resolved
Vessel was discovered to have a missed for its drydock exam. To maintain a valid COI, the vessel must complete its drydock exam every 2 years before date stated on COI. Vessel is restricted from carrying passengers for hire until it completes a satisfactory Drydock exam.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2025
Resolution: Hull exam completed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 March 2025 Resolved
Vessel completed dry dock and has not completed IFR / Egress drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: Conducted egress drills. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 March 2025 Resolved
Repair or replace stbd main engine sea valve, valve would not close all the way.
Action required: 705 - Other - as specified
Resolved 21 March 2025
Resolution: Valve was cleaned and lubricated, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 March 2025 Resolved
Small area of fiberglass de-lamination was identified on the port side / forward hull. Remove failed fiberglass and submit repair plan.
Action required: 705 - Other - as specified
Resolved 21 March 2025
Resolution: Failed layer of glass was removed to solid glass and repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2024 Resolved
Provide all three life ring buoys with new retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: retro-reflective tape was provided for all life rings.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 May 2024 Resolved
Seal forward engine room bulkhead (port and stbd) with fire proof caulking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: forward bulkhead was sealed with fire rated sealant.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024 Resolved
Provide 12V wheelhouse panel with breaker blank to fill the not used opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: Panel blank was provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 August 2023 Resolved
As stated in letter dated September 14, 2023, vessel must comply with Fire Safety of Small Passenger Vessels Interim Final Rule requirements by the next scheduled dry dock or 01JAN2026, whichever comes first. Vessel does not meet requirements and is restricted from carrying overnight passengers in accommodation spaces. National Defense Authorization Act for Fiscal Year 2024 (H.R. 2670), Section 3531(b)
Action required: 705 - Other - as specified
Resolved 4 April 2025
Resolution: Witness egress drills. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2023 Resolved
Both main engine exhaust found to be installed without protective insulation on areas that exceed 150 degrees. Install protective insulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 7 June 2023
Resolution: Installed insulation on turbos and exhaust piping.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2023 Resolved
The owner/operator shall instruct crew members on primary duties in cases of emergencies at least once every three months and log. Last logged drill was November, 2022. Must conduct emergency exercise/briefing with crew members in accordance with station bill prior to getting underway with passengers and log.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2023
Resolution: Vessel POC performed and logged drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2022 Resolved
Starboard Shaft sheared off. Vessel is required to make repairs prior to the carriage of passengers / cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2022
Resolved 12 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 May 2022 Resolved
Vessel radio safety certificate found to be expired. Provide valid radio safety certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Obtained new Safety Certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 May 2022 Resolved
Vessel VHF DSC radio found to be programmed without MMSI informaion. Program radio to include MMSI
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Programmed MMSI and GPS information.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 May 2022 Resolved
Multiple water pumps in the bilge found to be not secured. Secure pumps to prevent movement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2022
Resolution: Secured pumps from movement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2022 Resolved
Fuel shutoff valves found to be missing label. Label valve IAW CFR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Installed label for fuel shutoff valves.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2022 Resolved
Open wire found in pump room. Terminate wire IAW CFR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Terminated wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2022 Resolved
Twist on wire connectors are not permitted, remove and replace noted connector in engine room and on top of operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 7 June 2022
Resolution: Replaced connector with approved type.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 April 2021 Resolved
The battery on the vessel's EPIRB is expired. Replace the EPIRB battery if authorized by the manufacturer or provide a new Category 1 406 MHz EPIRB that is registered with NOAA. The vessel is restricted to no more than 3 NM from shore until this deficiency is resolved.
Action required: 705 - Other - as specified
Resolved 9 June 2021
Resolution: Operator acquired a new EPIRB which had a valid battery and registration. Witnessed a satifcactory test of the EPIRB.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 April 2021 Resolved
Provide lazarette hatch with captive chain fastened securely to the hatch frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Vessel provided hatch with a cord to secure the hatch to the hatch frame, and was found to be sufficient.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
Remove dead ended electrical cable found in pump room void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Visually identified that the dead-end wire had been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
Remove wire nuts from speaker cable behind helm and properly connect with pressure connectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Visually identified that the wire nuts had been swapped for pressure connectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 April 2021 Resolved
Provide stbd generator fuel lines with manufacture provided securing bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Visually identified new fuel line securing brackets on starboard generator, which are identical to the ones on the port generator.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2021 Resolved
Properly mount electric griddle in galley.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Crew screwed the upper section of the griddle's splash shielding to the B15 bulkhead to secure the griddle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 April 2021 Resolved
Provide approved type of bracket for 02 portable fire extinguishers: 1) galley & 2) aft bunk room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 10 June 2021
Resolution: Vessel acquired 02 new fire extinguisher brackets appropriate for each extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 April 2021 Resolved
Provide accurate instructions for the release of CO2 system, to include “pull pin” prior to pulling lever/handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 9 June 2021
Resolution: Owner had a new sign created and posted IVO the controls, which clearing instructed how to operate the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020 Resolved
VESSEL PORT SHAFT REPORTED SHEARED WHILE UNDERWAY AT SEA. MAKE AREAS IWO SHEARED SHAFT AVAILABLE FOR INSPECTION BY MARINE INSPECTOR. PROVIDE REPAIR PROPOSAL TO ATTENDING MARINE INSPECTOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2020
Resolved 9 October 2020
Resolution: Inspected by attending MI's.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 April 2020 Resolved
Port main fuel shut off could not shut off the fuel supply. Repair the port main fuel shut off.6930583
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2020 Resolved
Repair/replace the identified worn life buoy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 April 2020 Resolved
Provide FCC Marine Radio Operator Permit for all required licensed crew members. Vessel may not operate more than 1000 feet from shore until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 25 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 April 2020 Resolved
Six (05) flares were not of an approved type. Provide five (05) new flares of either the orange smoke, red hand, or red parachute type that are USCG 160.021 approved. Vessel is restricted to a "Lakes, Bays, and Sounds" route until this deficiency is corrected. 46 CFR 180.68.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 25 August 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2020 Resolved
Provide fire fighting equipment servicing document attesting to the correct operating of the fixed fire-fighting system shut-downs and override following generator replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2020
Resolved 25 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 April 2020 Resolved
Post COI under glass on board the vessel as per 46 CFR 176.302.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2020
Resolved 21 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2019 Resolved
Provide additional ladder rung near top of forward emergency exit. 46 CFR 177.15-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 13 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019 Resolved
Electrical equipment must be installed and maintained to protect passengers, crew and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Correct the following: (1) Remove or properly terminate (in j-box) dead-end wires found in crew bunk (2) Install spare cover on opening in distribution panel in wheelhouse. (3) Update labels in distribution panel in galley. 46 CFR 177.05-1(a)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 13 April 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2019 Resolved
Replace battery in smoke detector in passenger cabin on main deck. Install smoke detector at forward end of passenger accommodation below deck and in crew cabin (if door is installed). 46 CFR 181.450
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2019 Resolved
Mark fwd emergency escape on both sides w/ "EMERGENCY EXIT - KEEP CLEAR" in letters > 2". 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 25 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2019 Resolved
Provide and log training to all crew regarding use of fire-fighting equipment, engine room CO2 pull station, ventilation closures. 46 CFR 185.524
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Received email with picture of updated log book.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2019 Resolved
Provide current active employee list from consortium with all crew members. 46 CFR 16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2019
Resolved 13 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019 Resolved
Remove and replace welding cables with approved battery cables.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019 Resolved
Properly mount fuel transfer pump in machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019 Resolved
Replace defective fuel hoses on starboard side generator and port side main engine. Install guard on day tank sight glass.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 July 2019 Resolved
Replace defective pressure switch for main engine shutdown.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2019
Resolution: Replaced switch.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 July 2019 Resolved
Remove obstructions to fuel shutoff valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 1 August 2019
Resolution: Removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 July 2019 Resolved
Replace port and starboard rudder carrier bearings, prove proper operation of steering system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2019
Resolved 9 July 2019
Resolution: Replaced, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
CLSN: Vsl is broadcasting Invalid Call Sign, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: No longer in VIVS
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2018 Resolved
Vessel is restricted to carriage of 33 total persons until additional life raft/IBA is provided
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 June 2018 Resolved
Provide permanent fire dampers for both Port and STBD engine room vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2018 Resolved
No sail CG-835: Prove proper operation of the fire pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2018
Resolved 27 June 2018
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 June 2018 Resolved
Conduct underway emergency drills (Fire and Man overboard) in the presence of a CG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2018
Resolved 27 June 2018
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 June 2018 Resolved
Restricted route: Vessel may not operate more than 20NM from the closest point of land until a HF/MF radio with DSC is provided, properly installed, and certified on the vessels safety radiotelephony certificate.
Action required: 705 - Other - as specified
Due 25 July 2018
Resolved 27 June 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2018 Resolved
Make entire Drug and Alcohol program available for inspection
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 June 2018 Resolved
Galley range hood vent ducting needs a thorough cleaning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 1 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2018 Resolved
Provide adequate pulley/belt safety guards for the STBD generator and port Main propulsion engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 1 July 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 June 2018 Resolved
Provide valid medical cards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 June 2018 Resolved
Prove operation of bunk room bilge alarm visual signal (light.)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2018 Resolved
Properly install two main engine 24vlt breakers IVO forward STBD main engine overhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2018 Resolved
Engine room: Provide Junction box cover for 120vlt wiring
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2018
Resolved 27 June 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 June 2017 Resolved
Provide battery box lid at helm.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Lid installed.
Navigation › Piloting/Steering › Marine Charts
Issued 22 June 2017 Resolved
Provide current charts, coast pilot, tide tables, currents.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Publications provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2017 Resolved
Provide wire nuts for dead end wires under helm.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Wire nuts installed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 22 June 2017 Resolved
Secure forepeak hatch to rope/leash/line.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Forepeak secured.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 June 2017 Resolved
Provide smoke detector for upper stateroom.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Fire detector installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 June 2017 Resolved
Provide light and light cover in pump room.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Light and cover installed.
Engineering › Fuel Oil Service System › Pump
Issued 22 June 2017 Resolved
Mount and secure fuel pump.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Pump mounted.
Communications › Radio Communications › EPIRB
Issued 22 June 2017 Resolved
Provide NOAA EPIRB paper work.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: EPIRB documentaion provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2017 Resolved
Provide first aid kit.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: First aid kit provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 June 2017 Resolved
Post COI so passengers can view.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: COI posted in public view.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 June 2017 Resolved
Provide drug testing paperwork.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Drug testing documentation provided.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 June 2017 Resolved
Provide 65 lifejackets to meet COI requirement. 23 June 2017 - Provide 12 lifejackets to meet COI. 28 June 2017 - 12 life jackets provided to meet COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Resolution: All lifejackets on board vessel. Meet requirements of COI.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 22 June 2017 Resolved
Secure 04 junction boxes on top of pilot house.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Junction boxes secured.
Fire Fighting › Fire Hoses › Condition
Issued 22 June 2017 Resolved
Provide new port side firehose. Firehose wasted.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: New firehose provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 22 June 2017 Resolved
Lift CO2 tanks 2 inches off of deck.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 23 June 2017
Resolution: Tanks lifted 2 inches off of the deck.
Fire Fighting › Fire Hoses › Connections
Issued 22 June 2017 Resolved
Mount fire hoses so they are attached to the fire hydrant at all times.
Action required: 705 - Other - as specified
Due 23 July 2017
Resolved 28 June 2017
Resolution: Fire hoses mounted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 July 2016 Resolved
Provide EAP substance abuse hotline number posted
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 6 July 2016
Resolution: Properly posted EAP substance abuse hotline number
Communications › Alarms/Indicators › High Water Alarm
Issued 6 July 2016 Resolved
Prove proper operation of the high water level alarm for the bunk roo (prior to carrying passenger)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2016
Resolution: The nuetral wire was re-attached and tested.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 July 2016 Resolved
Properly secure upper deck rail system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Deck rail now properly secured
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 July 2016 Resolved
Label forward emergency escape hatch on both sides
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Escape hatch now labeled.
Stability › Watertight Integrity › General
Issued 6 July 2016 Resolved
Make forepeak hatch watertight
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Fore peak hatch is now water tight
Electrical › Lighting (service) › Switch
Issued 6 July 2016 Resolved
Install light switch cover in bunk room overhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Light switch cover is now installed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 July 2016 Resolved
Install guards on maintenance machinery pulleys
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Guards are now in place
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 July 2016 Resolved
install covers on 110 panel and junction box in pump room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Covers are now installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 July 2016 Resolved
Modify battery box cover in engine room to fit over terminals
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 30 September 2016
Resolution: Battery box was modified.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 6 July 2016 Resolved
Provide 8 adults sized life jackets
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 July 2016
Resolution: Added 8 adult sized life jackets
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 July 2014 Resolved
Provide proper blanks for breaker panel underneath bridge console.
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 12 August 2014
Resolution: Verfied blanks in place
Electrical › Electric Generation Source (service) › Conductor
Issued 7 July 2014 Resolved
Remove dead ended wires from under bridge console
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 12 August 2014
Resolution: Verified dead ended wires have been removed.
Documentation › Certificates/Documents › Stability Letter
Issued 7 July 2014 Resolved
Post stability letter in the vicinity of the operating station.
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 12 August 2014
Resolution: Stability letter has been posted IVO op station
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 July 2014 Resolved
Provide FCC safety certificate
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 12 August 2014
Resolution: Verified validity of FCC Safety Cert. New expiration date of 11Aug2019
Documentation › Logs/Records › Drug Test Records
Issued 7 July 2014 Resolved
Provide drug and alcohol testing equipment onboard
Action required: 705 - Other - as specified
Resolved 7 July 2014
Resolution: Drug testing equipment was provided.
Documentation › Logs/Records › Drug Test Records
Issued 7 July 2014 Resolved
Prove recent submission of MIS reporting documentation.
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 12 August 2014
Resolution: Verified that MIS reports have been submitted.
Communications › Radio Communications › EPIRB
Issued 7 July 2014 Resolved
Show proof of current Epirb registration (prior to operating beyond 3nm)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2014
Resolution: Current EPIRB registration onboard the vessel.
Fire Fighting › Fire Hoses › Condition
Issued 7 July 2014 Resolved
Replace starboard fire station hose and prove operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2014
Resolution: Hose was replced and tested sat
Stability › Watertight Integrity › General
Issued 9 June 2014 Resolved
Make forward escape hatch watertight.
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 12 August 2014
Resolution: Verified forward escape hatch is now watertight.
Documentation › Logs/Records › Drug Test Records
Issued 9 June 2014 Resolved
Show proof of current consortium enrollment.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 27 August 2014
Stability › Incline Test › General
Issued 1 December 2011 Resolved
Vessel delinquent in submitting COC for new AAWPP of 185lbs and has not conducted a new stability test. Reduced/restricted passenger count to 17 until corrected.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 2 December 2011
Resolution: Recieved Certification of Compliance Letter from Vessel O/op. Letter has been forwarded to MSC.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 29 September 2010 Resolved
No NOAA registration for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 1 October 2010
Resolution: E-mail received to confirm NOAA registration. Sticker not received yet.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 29 September 2010 Resolved
No expiration date provide on Hydro release for liferaft
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 4 October 2010
Resolution: Company who installed the liferaft was contacted and expiration date confirmed as 2011.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 September 2010 Resolved
Label external escape hatch "do not block"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 4 October 2010
Resolution: Properly labeled
Electrical › Lighting (service) › Lighting Fixture
Issued 29 September 2010 Resolved
Broken light bulb in aft center of enginroom is an electrical hazard. I checked it to see if it was live and it was.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 4 October 2010
Resolution: Light repaired and a cover installed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 September 2010 Resolved
Open circuit breaker on messdeck port side breaker panel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 4 October 2010
Resolution: Blank installed to prevent shock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2010 Resolved
Loose and exposed live wires in the lazeret need to be caped or removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 4 October 2010
Resolution: All dead end wires removed and dead ended wires placed in J-box.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 August 2009 Resolved
Engine room bilge has excessive oil collecting in bilge (Apx 9 inches). Vessel is restricted until bilge is clean of all oil.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 August 2009 Resolved
Both main diesel engines appear to have several leaks, on various systems, which appear to be contributing to an excessive build up of oil in engine room bilges. Vsl is required to have a certified manufacture technical representative provide a technical report, regarding the conditions of engines, and scope of repairs required. This report shall be submitted to CG prior to start of next drydock.
Due 12 May 2010
Resolved 15 April 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 July 2009 Resolved
Prove operation of fixed fire fighting engine shut down devise.
Action required: 705 - Other - as specified
Resolved 17 August 2009
Engineering › Bilge Water Management System › Not Operational
Issued 16 July 2009 Resolved
Prove operation of bilge dewatering system.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Lifesaving › Lifefloat › Lifeline
Issued 16 July 2009 Resolved
life floats are missing painter.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 July 2009 Resolved
Life float is missing float light.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 July 2009 Resolved
Lazarette high water alarm is not functioning.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 16 July 2009 Resolved
Missing B-I fire extinguisher and ensure proper location of B-II extinguisher in bunkhouse.
Action required: 705 - Other - as specified
Resolved 17 July 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 July 2009 Resolved
Compass light is not illuminating.
Due 16 August 2009
Resolved 17 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 16 July 2009 Resolved
Obtain FCC radio operator permit.
Due 16 August 2009
Resolved 21 August 2009
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 July 2009 Resolved
post emergency instructions as per 46 CFR 185.510
Due 15 August 2009
Resolved 21 August 2009
Navigation › Piloting/Steering › Marine Charts
Issued 16 July 2009 Resolved
Correct charts with local NTM or procure new required charts.
Due 15 August 2009
Resolved 21 August 2009
Fire Fighting › Fire Hoses › Condition
Issued 16 July 2009 Resolved
Female coupling on fire hose is tight and needs servicing.
Due 16 August 2009
Resolved 21 August 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 July 2009 Resolved
Several adult life jackets and two child size jackets were rejected by [name withheld] is restricted to carrying 46 adult and 4 children while on the zone one non-overnight trip route listed on COI.
Action required: 705 - Other - as specified
Resolved 6 October 2010
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 16 July 2009 Resolved
Several life jackets were found with out personal marking lights or the lights were not working Ensure all life jacket have operating lights as per 46 CFR 180.75
Action required: 705 - Other - as specified
Resolved 17 August 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 July 2009 Resolved
One life ring did not have the proper amount of retro-reflective tape as required by 46CFR 185.604
Due 16 August 2009
Resolved 17 July 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 July 2009 Resolved
The center engine needs a protective guard fabricated and installed around the FWD pulleys.
Due 16 August 2009
Resolved 21 August 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 July 2009 Resolved
Modify port battery cover so it is stable and secure as discussed with CGMI.
Due 16 August 2009
Resolved 21 August 2009
Construction/Loadline › Structures › Superstructure
Issued 16 July 2009 Resolved
Redesign Bunkhouse ventilation intake ducts located outside on FWD superstructure as discussed with CGMI, to keep water from entering the bilge during rough weather. Current design performs as a scoop allowing water to enter in to FWD bilge located in bunkroom. Correct deficiency at next scheduled Drydock.
Action required: 705 - Other - as specified
Due 31 May 2010
Resolved 15 April 2010
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 16 July 2009 Resolved
Fabricate or procure Rescue platform adequate enough to facilitate rescue of person in the water during a MOB situation.
Due 16 August 2009
Resolved 21 August 2009
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 16 July 2009 Resolved
MIS report not submitted; EAP hot line number nonexistent; Supervisory training not completed; substance abuse professional name and contact information not available. Chemical testing program is not in compliance. 8/21/09: additional 30 day extension granted to Vessel; correct by 17 Sep 09.
Action required: 705 - Other - as specified
Due 16 August 2009
Resolved 16 September 2009
Documentation › Certificates/Documents › FCC SSL
Issued 17 October 2008 Resolved
Provide current FCC Safety Radiotelephony Certificate, vessel restricted to 1000' from dock until corrected.
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 18 October 2008
Documentation › Logs/Records › Drug Test Records
Issued 17 October 2008 Resolved
Provide pre-employment drug test results for Joe and Myron, and update random drug testing crew list (remove Alex Centner).
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 October 2008 Resolved
Replace panel in galley where exposed electrical wires are present.
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 17 October 2008 Resolved
Repair loose railing on upper deck (at ladder).
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 October 2008 Resolved
Re-mount instructions for remote fuel shut-off valves (4) at reach rod location (E/R).
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 October 2008 Resolved
Label emergency exit from E/R ("Emergency Exit, Keep Clear").
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 October 2008 Resolved
Ensure PFD stowage location signage reflects actual number of adult/child PFDs stowed inside.
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Electrical › Lighting (service) › Outlet Box
Issued 17 October 2008 Resolved
Properly secure electrical outlet at operating station (stbd side bridge).
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 17 October 2008 Resolved
Provide ventilation closure devices for E/R blower ventilation ducts.
Action required: 705 - Other - as specified
Due 5 November 2008
Resolved 12 November 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 October 2007 Resolved
Provide valid Certificate of Documentation (COD).
Action required: 705 - Other - as specified
Due 11 October 2007
Resolved 12 October 2007
Communications › Radio Communications › EPIRB
Issued 11 October 2007 Resolved
Provide current NOAA EPIRB registration.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 14 November 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 October 2007 Resolved
Provide annual service fixed fire fighting system and portable fire extinguishers.
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 14 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 October 2007 Resolved
Repair mast head light.
Action required: 705 - Other - as specified
Due 11 October 2007
Resolved 11 October 2007
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 11 October 2007 Resolved
Repair/replace leaking water pump on port generator.
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 14 November 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 October 2007 Resolved
Remove non-combustible carpeting used throughout E/R.
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 14 November 2007
Engineering › Fuel Oil Service System › Filter
Issued 11 October 2007 Resolved
Provide missing bowl for racor for port generator.
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 14 November 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 October 2007 Resolved
Post COI where passengers have access, and post Stability Letter at operating station.
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 14 November 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 October 2007 Resolved
Provide current Coast Pilot [name withheld], Tide Tables, or applicable extracts.
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 14 November 2007
Fire Fighting › Grease Extraction Hood › General
Issued 3 January 2007 Resolved
Vsl/Owner was given six months to comply with CID policy letter #20 for his galley grease extraction hood.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 13 April 2007
Resolution: Vsl complies with Galley grease extraction policy.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 24 October 2006 Resolved
Vessel is overdue (beyond 90-day window) for annual inspection, therefore is restricted from operating with passengers until completing a satisfactory annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2006
Resolved 15 December 2006
Resolution: Vsl owner was advised of this and stated it wouldn’t happen again.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 October 2006 Resolved
Replace light cover switch on aft engine room bulkhead
Due 24 November 2006
Resolved 15 December 2006
Resolution: Cover was replaced
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 October 2006 Resolved
Cover open voids in electrical panel in engine room.
Due 24 November 2006
Resolved 15 December 2006
Resolution: Covers were installed
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 October 2006 Resolved
Repair or replace hose or fitting on port aft generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2007
Resolution: Piping was replaced and new hose was installed.
Engineering › Fuel Oil Service System › Piping
Issued 24 October 2006 Resolved
Install cap on fuel oil piping which was crimped and soldered.
Due 24 November 2006
Resolved 15 December 2006
Resolution: Line was capped
Construction/Loadline › Penetrations › Pipe Flange
Issued 24 October 2006 Resolved
Cap off piping (2) in pump room
Due 24 November 2006
Resolved 15 December 2006
Resolution: Pipes were capped off.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 October 2006 Resolved
Provide proof of enrollment and crew list, also write up current ships program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Program is up to date and in place.
Personnel › Training › First Aid/CPR
Issued 24 October 2006 Resolved
Ensure 50% of crew is CPR trained
Due 24 November 2006
Resolved 15 December 2006
Resolution: Crew is now 50 %.
Communications › Radio Communications › EPIRB
Issued 24 October 2006 Resolved
Replace expired hydro release on EPRIB, restricted to 3 miles
Due 24 November 2006
Resolved 15 December 2006
Resolution: Hydro release was renewed.
Lifesaving › Lifefloat › Painter
Issued 24 October 2006 Resolved
Replace all worn painter lines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Worn painter lines were replaced
Lifesaving › Lifefloat › Float-free Link
Issued 24 October 2006 Resolved
Renew float free links
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Float free links were replaced
Lifesaving › Lifefloat › Paddle
Issued 24 October 2006 Resolved
Properly secure paddles
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Paddles are secured
Lifesaving › Lifefloat › Serviceable
Issued 24 October 2006 Resolved
Properly stow all rafts
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Life rafts are properly stowed.
Lifesaving › Lifebuoys › Serviceable
Issued 24 October 2006 Resolved
Replace worn life buoy
Due 24 November 2006
Resolved 15 December 2006
Resolution: Life buoy was replaced.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 24 October 2006 Resolved
Replace missing handle on hatch for escape
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Cover was renewed.
Fire Fighting › Fire Hydrants › Condition
Issued 24 October 2006 Resolved
Replace both deck valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2006
Resolution: Both valves were replace.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 October 2006 Resolved
Rename FCC station license to current ships name.
Due 24 November 2006
Resolved 15 December 2006
Resolution: FCC station license was renewed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 October 2006 Resolved
Update CG light list and all pubs
Due 24 November 2006
Resolved 15 December 2006
Resolution: All pubs and charts are renewed.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 11 May 2006 Resolved
Replace gate valves on each generator (2 total); replace (1) ball valve each for the bait tank pump & deck wash-down pump per owner's PMS schedule.
Action required: 705 - Other - as specified
Resolved 17 May 2006
Resolution: New valves installed to replace the (4) valves that were removed.
Engineering › Freshwater System (jacketwater cooling) › Valve Manifold
Issued 11 May 2006 Resolved
Cap/seal gate valve discharge port no longer in service since the valve has been removed; pump room, stbd-side.
Due 22 May 2006
Resolved 17 May 2006
Resolution: Discharge port capped.
Stability › Watertight Integrity › General
Issued 11 May 2006 Resolved
Replace cables on all deck hatch covers upon completion of dry-dock. (Covers removed for maintenance)
Due 22 May 2006
Resolved 17 May 2006
Resolution: Re-attached cables on all hatch covers.
Engineering › Fuel Oil Service System › Filter
Issued 11 May 2006 Resolved
Remove fuel from fuel filter bowl on port engine.
Due 22 May 2006
Resolved 17 May 2006
Resolution: Fuel removed and bowl cleaned of debris.
Stability › Watertight Integrity › General
Issued 11 May 2006 Resolved
Seal small, thru-hull opening fm inside the pump-room thru to the laz on the stbd-side.
Due 22 May 2006
Resolved 17 May 2006
Resolution: Thru-hull opening sealed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 November 2005 Resolved
REPAIR/FIX EMERGENCY LIGHTING PROBLEM. EMERGENCY LIGHTS WERE INOPERABLE WHEN POWER IS SECURED AND EMERGENCY GENERATOR KICKS IN. VSL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL REPAIRED.
Action required: 705 - Other - as specified
Resolved 14 December 2005
Resolution: Repaired emergency lighting, tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 November 2005 Resolved
THE MAXIUM NUMBER OF PERSONS ALLOWED (PASSENGER & CREW) IS REDUCED TO NOT MORE THAN THIRTY (30) UNTIL ADDITIONAL PFDS HAVE BEEN PURCHASED TO ACCOMMODATE THE MAXIMUM NUMBER OF PERSONS ALLOWED PER THE COI.
Action required: 705 - Other - as specified
Resolved 18 May 2007
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 28 October 2005 Resolved
REPAIR/REPLACE INSTALLED BILGE VISUAL ALARMS TO REFLECT PROPER OPERATIONS OF ALL FOUR (4) BILGE ALARMS SO THEY WORK IN CONJUNCTION WITH THE AUDIBLE ALARMS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: BILGE ALARMS WERE REWIRED AND VISUAL ALARMS NOW WORK IN CONJUNCTION WITH THE AUDIBLE ALARMS.
Navigation › Piloting/Steering › Marine Charts
Issued 28 October 2005 Resolved
REPLACE OUTDATED NAVIGATIONAL CHART WITH CURRENT/UPDATED EDITION.
Due 15 November 2005
Resolved 7 November 2005
Resolution: NEW NAVIGATIONAL CHARTS WERE PURCHASED.
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 October 2005 Resolved
REPLACE OUTDATED U.S. COAST PILOT WITH CURRENT/UPDATED EDITION.
Due 15 November 2005
Resolved 7 November 2005
Resolution: A NEW U.S. COAST PILOT WAS PURCHASED.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 October 2005 Resolved
PROVIDE CURRENT EDITION OF TIDE & TIDAL CURRENT TABLE PUBLICATIONS. VSL HAS NO CURRENT PUBLICATIONS.
Due 15 November 2005
Resolved 7 November 2005
Resolution: A NEW TIDE & TIDAL CURRENT TABLE PUBLICATION WAS PURCHASED.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 October 2005 Resolved
REPLACE OUTDATED COAST GUARD LIGHT LIST WITH CURRENT/UPDATED EDITION.
Due 15 November 2005
Resolved 7 November 2005
Resolution: A NEW COAST GUARD LIGHT LIST PUBLICATION WAS PURCHASED.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 October 2005 Resolved
PRESENT/PROVIDE PROOF OF CURRENT DRUG TESTING PROGRAM WHICH INCLUDES ALL CREWMEMBERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: PROOF OF CURRENT ENROLLMENT OF ALL CREWMEMBERS WAS PRESENTED.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 October 2005 Resolved
PRESENT (FOR VERICATION) ORIGINAL LICENCES FOR BOTH OF THE VSL'S LICENCED MASTERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: THE ORIGINAL LICENSES FOR BOTH MASTERS WERE PRESENTED & VERIFIED.
Documentation › Certificates/Documents › FCC SSL
Issued 28 October 2005 Resolved
PRESENT (FOR VERIFICATION) ORIGINAL FCC SAFETY RADIO-TELEPHONY CERTIFICATE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: THE ORIGINAL FCC SAFETY RADIO-TELEPHONY CERTIFICATE WAS PRESENTED & VERIFIED.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 October 2005 Resolved
PRESENT (FOR VERIFICATION) THE VSL'S ORIGINAL DOCUMENTATION CERTIFICATE. A PHOTOCOPY IS NOT ACCEPTABLE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: THE ORIGINAL DOCUMENTATION CERTIFICATE WAS PRESENTED & VERIFIED.
Communications › Radio Communications › EPIRB
Issued 28 October 2005 Resolved
PROVIDE PROOF OF CURRENT EPRIB REGISTATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: PROOF OF CURRENT REGISTRATION WAS PRESENTED & VERIFIED.
Lifesaving › Lifefloat › Not on Board
Issued 28 October 2005 Resolved
THREE (3) LIFERINGS ARE REQUIRED FOR VSLS OVER 65 FT. AN ADDITIONAL LIFERING IS REQUIRED BECAUSE THE VSL ONLY HAS TWO (2) ONBOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: AN ADDITIONAL LIFERING WAS PURCHASED TO COMPLETE THE THREE (3) LIFERING REQUIREMENT.
Lifesaving › Lifebuoys › Serviceable
Issued 28 October 2005 Resolved
REPAIR/REPLACE INOPERABLE LIFERING WATER LIGHT AND RE-LABEL WITH THE CURRENT VESSEL NAME.
Due 15 November 2005
Resolved 7 November 2005
Resolution: MASTER REPAIR INOP WATERLIGHT.
Communications › Alarms/Indicators › Fire Alarm
Issued 14 June 2004 Resolved
Install smoke detector unit in overnight accomodation area IAW 46CFR181.400(c)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 28 June 2004
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 June 2004 Resolved
Repair distribution panels on bridge IAW 46CFR183.330 (e)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 June 2004 Resolved
Replace stbd side junction box in lazarrette IAW 183.210(2)(c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2004 Resolved
Remove dead end wires from lazarrette wire run IAW 183.200
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 June 2004 Resolved
Procure and provide covers for blue and grey junction boxes in lazarrette IAW 183.210(2)(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Electrical › Electric Generation Source (service) › Panelboard
Issued 14 June 2004 Resolved
Provide a dead front in circuit breaker boxes in engine room IAW 183.330(b)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Electrical › Electric Generation Source (service) › Generator
Issued 14 June 2004 Resolved
Clean generator windings IAW 183.330(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 June 2004 Resolved
Repair generator control switch IAW 46CFR183.200(c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 June 2004 Resolved
Procure pin for stbd side sea gate IAW 179.360(b)(2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 June 2004 Resolved
Repair crack in frame on port side in lazarrette space IAW 177.300
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Stability › Incline Test › General
Issued 14 June 2004 Resolved
Resolve stability issue via Naval Architect and MSC Inspector David Crede. Naval Architect needs to provide more raw data from incline test.
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 16 November 2004
Resolution: Received stability letter from MSC.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 June 2004 Resolved
Re-crimp lazarrette safety chain on watertight hatch IAW 46CFR179.360(b)(2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 29 June 2004
Engineering › Bilge Water Management System › Not Operational
Issued 14 June 2004 Resolved
Remove excess oil from bilge caused by maintenance on generator IAW 176.830(b)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 1 July 2004
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 May 2004 Resolved
Properly repair cracked vertical side shell framing IWO Port #2, 4, & 6 and Stbd #6. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Due 15 July 2004
Resolved 28 June 2004
Construction/Loadline › Hull › Transverse Frame
Issued 26 May 2004 Resolved
Properly repair de-laminated fiberglass "tab" on first transverse frame in the engine room, port side, just aft of the fuel tank. (The delaminated portion is where the matt is wrapped over the frame and attaches to the hull to provide strengthening.
Condition: Unknown
Due 15 July 2004
Resolved 28 June 2004
Stability › Watertight Integrity › General
Issued 26 May 2004 Resolved
Provide proper metallic bulkhead penetrations for PVC piping systems traversing watertight bulkheads. LEGACY COMPONENT DESC: PVC Piping Penetrations
Condition: Improper Installation
Due 15 July 2004
Resolved 28 June 2004
Stability › Watertight Integrity › Weathertight Enclosure
Issued 26 May 2004 Resolved
Provide Captive Chains for all watertight hatches. LEGACY COMPONENT DESC: Watertight Hatches
Due 15 July 2004
Resolved 29 June 2004
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 26 May 2004 Resolved
Provide current FCC Safety Radiotelephony Certificate
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2004
Resolved 28 June 2004
Communications › Radio Communications
Issued 26 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 July 2004
Resolved 26 May 2004
Resolution: Redundant requirement
Communications › Radio Communications › VHF Radiotelephone
Issued 26 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 July 2004
Resolved 28 June 2004
Stability › Incline Test
Issued 29 May 2003 Resolved
Conduct incline test prior to next operating season. This requirement is due to weight changes made during modification and will provide you with a new stability letter. Incline procedure is to be approved by Marine Safety Center and observed by MSO San Diego.
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 26 May 2004
Resolution: Witnessed satisfactory inclining test.
Communications › Radio Communications
Issued 18 February 2003 Resolved
SSB radio will not transmit. Vessel issued requirement to operate within 100 miles of shore until radio is operational. Owner can fax repair reciept to Mso to clear requirement.
Action required: 705 - Other - as specified
Due 18 March 2003
Resolved 22 May 2003
Resolution: Recieved fax reciept for purchase of Single Side Band radio
Operations/Management
Issued 16 December 2002 Resolved
Have onboard a copy of T boat anf FCC regulations
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Electrical › Electrical Distribution System (service)
Issued 16 December 2002 Resolved
Replace panel cover on 115v panelboard under bridge instruments LEGACY COMPONENT DESC: Panelboard
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Navigation › Piloting/Steering
Issued 16 December 2002 Resolved
Have onboard current compass deviation table LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Engineering
Issued 16 December 2002 Resolved
Plug sea valve on hull in stbd engineroom aft.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Engineering › Steering Gear System
Issued 16 December 2002 Resolved
Renew upper rudder bearings next dry dock LEGACY COMPONENT DESC: Rudder Bearing
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 26 May 2004
Operations/Management
Issued 16 December 2002 Resolved
Provide Garbage, EPIRB, FCC and Lifesaving Logs.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Resolution: Provided
Documentation › Certificates/Documents
Issued 16 December 2002 Resolved
Have onboard FCC Safety Certificate and Station License.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Fire Fighting › Fire Main
Issued 16 December 2002 Resolved
Repair leak on fire main system on engine room overhead
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 December 2002 Resolved
have onboard First Aid Kit.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 16 December 2002 Resolved
Install emergency egress lighting in forward berthing.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Construction/Loadline › Structures
Issued 16 December 2002 Resolved
Repair as new structural deck beams in overhead of engine room in way of wood rot
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 26 May 2004
Resolution: Owner renewed aft deck
Construction/Loadline › Structures
Issued 16 December 2002 Resolved
Repair deck as new in way of aft soft patch on main deck
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 26 May 2004
Documentation › Certificates/Documents
Issued 12 November 2002 Resolved
Provide original Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Pollution Prevention/Response
Issued 12 November 2002 Resolved
Have on board a waste management plan as required by 33 CFR 151.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 November 2002 Resolved
Have on board and maintain drill training and logs as required by 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Operations/Management
Issued 12 November 2002 Resolved
Maintain crew list and passenger count as required by 46 CFR 185.502/504.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Communications
Issued 12 November 2002 Resolved
Provide FCC station license and safety certificate.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Operations/Management
Issued 12 November 2002 Resolved
Provide proof the vessel/company complies with the drug testing regulations of 46 CFR part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Lifesaving
Issued 12 November 2002 Resolved
Renew 406 EPIRB hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Navigation › Piloting/Steering
Issued 12 November 2002 Resolved
Provide a current copy of the lightlist, coast pilot, and notice to mariners for the vessel's new area of operations. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 12 November 2002 Resolved
Have on board smoke detectors in way of accommodation spaces. This requirement shall be accomplished prior to sailing with passengers in the overnight accommodations.
Due 12 December 2002
Resolved 16 December 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 November 2002 Resolved
Provide plans for modifications to fixed fire extinguishing system in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 19 December 2002
Fire Fighting › Fire Pumps
Issued 12 November 2002 Resolved
Renew fire pump guage.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Engineering › Shafting/Propeller Arrangements
Issued 12 November 2002 Resolved
Repair as new port shaft packing gland. LEGACY COMPONENT DESC: Stern Tube
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Electrical › Electric Supply System (service)
Issued 12 November 2002 Resolved
Submit proposal to re-wire bilge alarms as required by 46 CFR part 183. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 2 June 2003
Resolution: Reviewed and approved plans.
Construction/Loadline › Penetrations
Issued 12 November 2002 Resolved
Make all PVC or plastic bulkhead penetrations watertight as required by 46 182.720(d)(i).
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Fire Fighting › Fire Main
Issued 12 November 2002 Resolved
Repair as new R/W leaking pipes in firemain piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2003
Resolved 18 February 2003
Engineering
Issued 12 November 2002 Resolved
Renew pressure temperature relief valve with valve not to exceed 100 psig.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 November 2002 Resolved
Replace fire extinguisher brackets with approved brackets. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Electrical › Electric Supply System (service)
Issued 12 November 2002 Resolved
Secure all bare wires in AC & DC electrical system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 November 2002 Resolved
Submit proposal to install fixed fire extinguishing system above galley griddle in accordance with 46 CFR 181.400(d)
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Resolution: griddle was removed from vessel
Electrical › Electric Supply System (service)
Issued 12 November 2002 Resolved
Install all wiring in all AC pumps correctly in way of wiring clamps.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 November 2002 Resolved
Repair as new fuel oil leaks on stbd generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 16 December 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 12 November 2002 Resolved
Renew fuel oil hose on both generators with approved hoses as required by 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Engineering
Issued 12 November 2002 Resolved
Install double hose clamps on all R/W pedro connections.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Electrical › Electric Supply System (service)
Issued 12 November 2002 Resolved
Support all AC & DC electrical wiring runs as required by 46 CFR part 183.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Electrical › Lighting (service)
Issued 12 November 2002 Resolved
Provide protection for all exposed AC/DC lamps. (Luminaries)
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 18 February 2003
Construction/Loadline › Structures
Issued 12 November 2002 Resolved
Make all watertight bulkheads watertight. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 12 November 2002 Resolved
Properly support exhaust piping in way of aft compartment.
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Lifesaving
Issued 31 July 2001 Resolved
STENCIL EMERGENCY ESCAPE IN #2 COMPT.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Navigation
Issued 31 July 2001 Resolved
PROVIDE UPDATED CHARTS.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Documentation
Issued 31 July 2001 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Navigation
Issued 31 July 2001 Resolved
RE-ATTACH RUDDER SHAFT BONDING STRAP.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Engineering
Issued 31 July 2001 Resolved
CONNECT AND OPERATIONALLY CHECK FUEL OIL EMERGENCY SHUT-OFF REACH ROD.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Engineering
Issued 31 July 2001 Resolved
PROVE PROPER OPERATION OF MDE LUBE OIL PRESSURE GAUGE.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Navigation
Issued 31 July 2001 Resolved
VESSEL IS RESTRICTED FROM NIGHT-TIME OPERATIONS UNTIL NAVIGATION LIGHTS HAVE BEEN TESTED IN THE PRESENCE OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Engineering
Issued 31 July 2001 Resolved
STBD SSDG NOT TO BE USED UNTIL FUEL OIL LEAK IS REPAIRED AND A OPERATIONAL CHECK COMPLETE IN THE PRESENCE OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Navigation
Issued 3 August 1999 Resolved
PROVIDE CURRENT TIDE AND CURRENT TABLES.
Condition: Unknown
Due 17 September 1999
Resolved 17 September 1999
Electrical
Issued 3 August 1999 Resolved
PROPERLY MOUNT AND WIRE BOTH HEAD PUMPS.
Condition: Unknown
Due 17 September 1999
Resolved 17 September 1999
Lifesaving
Issued 29 July 1998 Resolved
PROVIDE RENEWED RETRO TAPE ON FORWARD CABIN L/F BOTTOM.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 29 July 1998 Resolved
SEPERATE PAINTER TO FLOAT FREE CONFIGURATION.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 29 July 1998 Resolved
PROVIDE PROPER RING BOUT PAINTER LINES.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Fire Fighting
Issued 29 July 1998 Resolved
PROVIDE 1 APPROVED 1.5" FIRE HOSE.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Construction/Loadline
Issued 29 July 1998 Resolved
RENEW BILGE LINE IN #2 COMP.
Condition: Unknown
Due 29 July 1998
Resolved 29 July 1998
Lifesaving
Issued 29 July 1998 Resolved
PROVIDE RENEWED PAINTER LINE ON L/F ON BRIDGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 29 July 1998 Resolved
PROVIDE RENEWED WATER LIGHT PAINTER LINE.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 29 July 1998 Resolved
RENEW RETRO TAPE ON CABIN TOP L/F BOTTOM.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 29 July 1998 Resolved
PROPERLY STOWE HAND LINES OF ALL L/F.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Navigation
Issued 1 August 1995 Resolved
PROVIDE PROOF OF CHEMICAL TESTING PROGRAM._x001C_ _x001C_ _x001C_ X
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Navigation
Issued 1 August 1995 Resolved
PROVIDE AND POST THE VESSEL STABILITY LETTER IN THE WHEEL HOUSE.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Navigation
Issued 1 August 1995 Resolved
PURCHASE A COPY OF THE NOTICE TO MARINERS.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Electrical
Issued 7 January 1995 Resolved
Repair base to decklight on portside, upper deck.
Condition: Unknown
Due 14 January 1995
Resolved 17 February 1995
Lifesaving
Issued 7 January 1995 Resolved
Replace missing waterlight on ring life buoy.
Condition: Unknown
Due 14 January 1995
Resolved 17 February 1995
Engineering
Issued 7 January 1995 Resolved
Repair leak on salt water washdown pump discharge on starboard side of engineroom forward.
Condition: Unknown
Due 14 January 1995
Resolved 17 February 1995
Engineering
Issued 9 August 1993 Resolved
PROVE PROPER OPERATION OF CENTER MDE. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR NO LATER THAN 16AUG93.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Documentation
Issued 9 August 1993 Resolved
PROVIDE CURRENT NAVIGATION RULES NO LATER THAN 16AUG93.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Fire Fighting
Issued 9 August 1993 Resolved
PROVIDE APPROVED NOZZEL FOR FIRE HOSE NO LATER THAN 16AUG93.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Documentation
Issued 9 August 1993 Resolved
PROVIDE ORIGINAL CERTIFICATE OF DOCUMENTATION NO LATER TAHN 16AUG93.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 7 August 1992 Resolved
INSTALL PROPER FUEL HOSE FOR EMERGENCY GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 November 1992
Resolved 3 November 1992
Accommodation/Occupational Safety
Issued 7 August 1992 Resolved
INSTALL DECK RAILS NEAR THE PERIPHERY OF ALL WEATHER DECKS ACCESSIBLE TO PASSENGERS AND CREW 36" HIGH, 12" SPACE BETWEEN EACH COURSE._x001C_
Condition: Unknown
Due 2 November 1992
Resolved 3 November 1992
Documentation
Issued 7 August 1992 Resolved
PROVIDE & POST FCC SAFETY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 November 1992
Resolved 3 November 1992
Engineering
Issued 7 August 1992 Resolved
PROPERLY MARK REMOTE FUEL SHUTOFF STATIONS TO THE SATISFACTION OF ATTENDINGMARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1992
Resolved 21 August 1992
Lifesaving
Issued 7 August 1992 Resolved
PROVIDE 10 ADDITIONAL ADULT LIFEPRESERVERS FOR 80 TOTAL PERSONS. MANNING REDUCED TO 70 PERSONS UNTIL CLEARED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 November 1992
Resolved 3 November 1992

Casualty record · 6

22 May 2012Routine · role: Involved in a Marine Casualty · activity 4321741
17 May 2016Major Marine Casualty · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · activity 5879927
1 October 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6560021
14 September 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6856423
5 October 2020Routine · role: Involved in a Marine Casualty · activity 7086060
7 August 2022Routine · role: Involved in a Marine Casualty · activity 7531284
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.