Records from 1985 to 2023. Most recent: inspection, 22 November 2023.
Inspection history · 67
22 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7826231
5 December 2022
Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7600886
20 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7577543
4 May 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7182553
4 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7135527
13 November 2020
Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094410
19 November 2019
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6857714
17 December 2018
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6599067
20 November 2018
Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583894
24 May 2018
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6423002
20 February 2018
DAPI Audit · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6358284
18 September 2017
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6262171
21 August 2017
Administrative Inspection · Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6247650
27 July 2017
Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6223902
3 July 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6196421
21 September 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6005589
21 September 2015
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5726029
8 October 2014
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4997861
20 August 2014
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5001813
21 August 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4124459
23 November 2010
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3898558
4 May 2009
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3465396
20 April 2009
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3457074
28 July 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3207608
16 May 2007
Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2934276
19 April 2007
COI Inspection · Simplified Stability Test · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2910999
26 April 2006
COI Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2630091
29 June 2005
Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2408673
24 August 2004
Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2174827
13 July 2004
Periodic Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2131951
20 May 2003
Re-Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 1797733
22 May 2001
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1066900
27 April 2001
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426617
15 May 2000
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1381899
9 November 1999
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 804207
4 June 1999
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1410121
24 May 1999
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1442838
3 June 1998
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1129285
11 May 1998
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1392929
22 May 1997
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1457461
5 May 1997
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1402449
25 October 1996
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1163291
26 August 1996
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1088340
11 July 1996
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1086863
29 May 1996
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1439750
28 June 1995
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1191362
10 May 1995
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1405701
12 July 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1177113
4 May 1994
Hull Examination · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1439513
9 June 1993
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 845088
6 June 1992
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1260969
11 May 1992
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1260968
16 July 1991
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1249507
20 May 1991
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 927784
26 June 1990
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 899753
2 May 1990
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 929602
9 June 1989
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1350724
8 May 1989
COI Inspection · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1350224
26 May 1988
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1203949
29 June 1987
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1011591
22 May 1987
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1028281
10 October 1986
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1007868
5 June 1986
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1298415
19 April 1986
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 988794
13 June 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1287761
16 May 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 986018
3 April 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1287422
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 22 November 2023
No resolution recorded
All vessels must have operable navigation lights in accordance with the Navigation Rules. Starboard light was inoperable. Provide starboard navigation light.
46 CFR 183.420
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2023
No resolution recorded
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy grab line deteriorated and in need of replacement.
46 CFR 176.808(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2023
No resolution recorded
All fuel tanks must be electrically bonded to a common ground. Grounding wire for fuel tank is missing in engine room and in generator room. Install common grounding wire to fuel tanks.
46 CFR 182.440(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2023
No resolution recorded
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire and electrical shock. Cover on outlet in wheel house missing. Install proper cover plate on outlet.
46 CFR 183.200 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 November 2023
No resolution recorded
Battery chargers must have an ammeter connected in the charging circuit. Install ammeters for both battery
chargers.
46 CFR 183.350(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2023
No resolution recorded
Each life ring buoy must be marked in clearly legible block capital letters with the vessel's name. Mark life ring buoy with vessel name.
46 CFR 185.604
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 22 November 2023
No resolution recorded
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Starboard engine missing cover or guard over belt. Install guard.
46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 November 2023
No resolution recorded
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are not lashed to the life floats. Properly arranged paddles to life floats.
46 CFR 180.175(f)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 November 2023
No resolution recorded
The light required for life floats must be a floating waterlight approved under 161.010 and attached around the body of the life float by a 3/18 inch lanyard, resistant to deterioration from ultraviolet light, and at least 18 feet in length. Waterlight housing for one life float is cracked and light is not illuminating. Install new floating waterlight approved under 161.010.
46 CFR 180.175(f)(4)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 November 2023
No resolution recorded
When stowed in tiers, the separate units must be kept apart by spacers. Life floats found stacked two high with no spacers in between tiers. Install spacers between life float tiers.
46 CFR 180.137(4)(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2023
No resolution recorded
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Three life jackets had deteriorated retroreflective material. Provide appropriate markings to the satisfaction of the attending marine inspector.
46 CFR 185.604
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 November 2023
No resolution recorded
Each vessel certificated to operate on a limited coastwise route within three miles of land in warm water must have on board a FCC Type Accepted Category 1 406 MHz EPIRB, installed to automatically float free and activate. The vessels EPIRB HRU is beyond the expiry date. Vessel shall not operate beyond 3nm from shore until the HRU is replaced.
46 CFR 180.205(e)
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 October 2022
Resolved
Each vessel constructed of a material other than wood certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons on board. MI discovered 01 20 person life float to be severely worn. Vessel to provide serviceable life float. Vessel restricted to operating no more than 3 NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 15 December 2022
Resolution: Vessel repaired life float with manufacturer's repair kit; all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2022
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Vessel only had four of the six hand red flare distress signals. Vessel to provide all of the required six red hand flare distress signals. Vessel restricted to operating no more than 3 NM from shore.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 26 October 2022
Resolution: Vessel sent objective evidence of purchasing new red hand flares, all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 October 2022
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears,
machinery, etc. MI discovered guard missing over flywheel of port main engine. Vessel to provide suitable guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 26 October 2022
Resolution: Vessel provided objective evidence of installing a new guard over the rotating machinery, all satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2021
Resolved
Seats used to determine the number of passengers permitted, in accordance with 46CFR176.113(b)(3) of this chapter, must be secured to the deck, bulkhead, or bulwark. The six boxes on the upper deck and the two boxes on the bow that are used for passenger seating are not secured to the deck. No passengers shall be carried on the upper deck or on the bow while propulsion is engaged until a repair proposal is submitted for review and approval by the attending USCG Marine Inspector, and those approved repairs are completed to the satisfaction of the attending USCG Marine Inspector. Total passenger count is reduced by 32 passengers, to a total of 42 passengers allowed on board, due to the prohibited use of these seats.
46CFR177.820(d)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 November 2021
Resolution: Attended vessel and verified satisfactory secured deck boxes used for passenger seating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2021
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. The flexible fuel hose from the port fuel tank to the port engine is wasted and shall be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 2 March 2021
Resolution: Received email with photographs attesting to the installation of SAE J1942 fuel lines.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 February 2021
Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. The vessel has exposed electrical conductors located on the outboard sides of both main engines, coming from the bottom of the electrical panel forward of the generator, and penetrating the bulkhead between the compressor and rudder compartments. All exposed conductors shall be secured or removed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2021
Resolved 25 February 2021
Resolution: Attended vessel and observed removed exposed electrical wiring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 February 2021
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. The top deck rail on the port quarter of the vessel is missing and shall be replaced.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 25 February 2021
Resolution: Attended vessel and verified proper labeling of upper deck capacity.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 February 2021
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The vessel does not have logs documenting drills or training.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2021
Resolved 25 February 2021
Resolution: Attended vessel and witnessed satisfactory drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2021
Resolved
To maintain a valid Certificate of Inspection (COI), you must complete your annual inspection within the periods specified in §176.500(b)(1) and your COI must be endorsed. Vessel has exceeded the 3 month window from its anniversary date for an annual inspection without completing required inspection. Vessel shall not carry passengers until both a credit drydock and an annual COI inspection have been satisfactorily completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2021
Resolution: Credit drydock given and COI inspection completed on 26 August 2021.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 November 2019
Resolved
A pre-engineered fixed gas fire extinguishing system must: automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. When the engine room pre-engineered fixed gas fire extinguisher was activated it shut down the engines and activated an alarm. With the pre-engineered fixed gas fire extinguisher still activated and the override switch in the normal (off) position the engines were capable of being started and continued to run.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2019
Resolved 5 December 2019
Resolution: Tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2019
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The starboard engine full shut off handle is not permanently connected to the full shut off valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Fuel shutoff is permanently installed with hexnuts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2019
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The mounting bracket on the obsolete alternator on the port side of the port engine is cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Mounting bracked removed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 November 2019
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The vent closures when closed leave an approximate 1/6 inch gap.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Tightly secured with strap.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2019
Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form (OMB Number: 2105-0529) by mail to Commandant (CG-INV). Annual MIS report was not provided during the course of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 10 December 2019
Resolution: Reviewed submitted information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2019
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. During the course of the inspection the supervisory personnel was unable to provide proof of the required 60 minutes of training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 10 December 2019
Resolution: Reviewed EAP training information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2019
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. The vessel did not have the required EAP education program information displayed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 10 December 2019
Resolution: Required EAP information displayed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 November 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The mast running light's mount has corroded extensively leaving the lightbulb to be improperly displayed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Mast head light assembly replace and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 November 2019
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: On each life float and buoyant apparatus. On all three lifefloats the vessel's previous name is still legible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 5 December 2019
Resolution: Name properly stenciled on the life float.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 December 2018
Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced before the date required by FCC Regulations in 47 CFR Part 80; Vessel EPIRB Battery is past expiration date. Replace EPIRB Battery. Vessel route restricted to less than or equal to 3 NM. 46 CFR 185.728 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 1 January 2019
Resolution: Vessel rep emailed pic of new EPIRB with new battery.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 December 2018
Resolved
The master shall ensure that the EPIRB test required by Paragraph (a) shall be logged or otherwise documented as applicable; vessel does not have EPIRB tests logged. Log EPIRB tests. 46 CFR 185.728 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 1 January 2019
Resolution: Vessel rep emailed pic of log entry of EPIRB tests.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 December 2018
Resolved
Placards containing instructions for the donning and the use of life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers; vessel does not have placards posted. Post placards. 46 CFR 185.516 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 1 January 2019
Resolution: Vessel rep emailed pic of placard posted on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 December 2018
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing actions to be taken in the event of man overboard conditions; vessel doesn't have instructions for man overboard posted. Post instructions. 46 CFR 185.510 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 1 January 2019
Resolution: Vessel rep submitted picture of MOB procedures mounted at operating station.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 December 2018
Resolved
On a vessel not more than 65 ft in length, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces of the vessel during normal operating conditions; vessel has no PA system and wants to use Bullhorn. Obtain bullhorn to serve as vessel PA system. 46 CFR 184.610 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 1 January 2019
Resolution: Vessel rep emailed picture of bullhorn on vessel
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar publication, Coast Guard Light List; Vessel's Coast Pilot and Light List are out of date. Replace publications with up to date versions. 46 CFR 184.420 (a)(2) and (3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 1 January 2019
Resolution: Vessel rep emailed pictures of updated publications.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 December 2018
Resolved
Except as allowed by paragraph (e) of this section, each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board; one of the vessel's life floats was cracked and unusable. Replace life float. 46 CFR 180.205 (c)
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Vessel rep replaced cracked 15 man life float with 22 man life float. Weak link was replaced as well to accommodate new weight.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 December 2018
Resolved
Each life jacket must be marked with type I retro-reflective material. The arrangement of the retro-reflective material applied after march 11, 1996 must be as specified by IMO Resolution A.658(16); 15 Life Jackets need new retro-reflective material applied. Add new retro-reflective material. 46 CFR 185.604 (h)
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Vessel rep added new retro-reflective material to required life jackets.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 September 2017
Resolved
Provide guard for expoxed belts on starboard engine in accordance with 46 CFR 177.960.
Condition: Improper Installation
Due 10 October 2017
Resolved 10 October 2017
Resolution: Guard installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 September 2017
Resolved
Arrange ring lifebuoy with light and buoyant line in accordance with 46 CFR 180.70.
Condition: Improper Installation
Due 10 October 2017
Resolved 10 October 2017
Resolution: Ring lifebuoy arranged with light and buoyant line in accordance with 46 CFR 180.70.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 September 2017
Resolved
Provide and post emergency instructions onboard vessel in accordance with 46 CFR 185.510 and 185.512.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: Emergency instructions posted onboard vessel in accordance with 46 CFR 185.510 and 185.512.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 September 2017
Resolved
Provide proof of completion and creation of crew training log in accordance with 46 CFR 185.420.
Due 10 October 2017
Resolved 10 October 2017
Resolution: Verified creation of crew training logs.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 18 September 2017
Resolved
Conduct safety orientation in accordance with 46 CFR 185.506.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: Safety orientation conducted in accordance with 46 CFR 185.506.
Engineering › Steering Gear System › Rudder Stock
Issued 18 September 2017
Resolved
Eliminate excessive leaking from port and starboard rudder post seals while underway to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 10 October 2017
Resolution: Verified operation of steering gear and excessive leaking at rudder post stopped.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 September 2017
Resolved
Conduct satisfactory DAPI compliance audit in accordance with 46 CFR Part 16 and 40.
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 20 February 2018
Resolution: Conducted satisfactory DAPI audit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 September 2017
Resolved
Prove proper operation of starboard navigation running light in accordance with 46 CFR 183.470. Vessel is restricted to day time operations until corrected.
Condition: Improper/Lack of Maintenance
Due 10 October 2017
Resolved 19 September 2017
Resolution: Recieved satisfactory proof of operation of starboard navigation light.
Lifesaving › Lifefloat › Markings
Issued 18 September 2017
Resolved
Lable all lifefloats with vessel name in accordance with 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Due 19 September 2017
Resolved 18 September 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 September 2017
Resolved
Lable ring life buoy with vessel name in accordance with 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Due 19 September 2017
Resolved 18 September 2017
Communications › Alarms/Indicators › High Water Alarm
Issued 18 September 2017
Resolved
Install bilge high water alarm in steering gear compartment in accordance with 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 24 May 2018
Resolution: Witnessed installation of high water alarm and operation of alarm at the operating station.
Construction/Loadline › Structures › Deck Plating
Issued 21 August 2017
Resolved
A new swim platform was installed on this vessel with-out approved plans. Provide approved plans and prove proper construction iaw the plans.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 24 May 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 July 2017
Resolved
Vessel is restricted from carrying more than 6 passengers until vessel has received credit dry dock. 46 CFR 176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2017
Resolved 27 July 2017
Resolution: Completed Credit Dry-dock Examination.
Construction/Loadline › Structures › Trunk
Issued 21 September 2016
Resolved
Aft deck hatch coaming was found to be wasted.
Due 15 February 2017
Resolved 15 February 2017
Resolution: Owner provided proof of resolution.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 September 2015
Resolved
Renew fire extinguisher bracket on bridge or ensure proper fire extinguisher is installed.
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 24 September 2015
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 21 September 2015
Resolved
Prove proper operation of mast and anchor lights.
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 24 September 2015
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 21 September 2015
Resolved
Renew sewage tank due to multiple leaks.
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 14 October 2015
Operations/Management › Drills/Instruction › Fire
Issued 21 September 2015
Resolved
Conduct fire and man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2015
Resolved 24 September 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 21 September 2015
Resolved
Prove proper operation of both main engines and steering system while underway.
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 24 September 2015
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 October 2014
Resolved
Provide current navigation publications including Coast Pilot [name withheld], tide and current tables.
Due 5 November 2014
Resolved 6 November 2014
Resolution: Emailed copies of pubs downloaded, printed, and put on vessel
Communications › Radio Communications › EPIRB
Issued 29 October 2014
Resolved
Install EPIRB such that it can automatically float free and activate.
Action required: 705 - Other - as specified
Resolved 29 October 2014
Resolution: Operator remounted EPIRB on railing to permit it to automatically float free.
Lifesaving › Lifefloat › Painter
Issued 29 October 2014
Resolved
Replace weathered, unserviceable lifefloat painters
Action required: 705 - Other - as specified
Resolved 29 October 2014
Resolution: A crewmember purchased and installed 3 new 100'''' lengths of black synthetic painter lines, one for each lifefloat
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 October 2014
Resolved
Provide aspirin for first aid kit
Action required: 705 - Other - as specified
Resolved 29 October 2014
Resolution: Provided aspirin for first aid kit.
Documentation › Logs/Records › Logbook (official)
Issued 4 May 2009
Resolved
Provide proof of user fee payment and receipt.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Provided receipt for payment of user fee.
Fire Fighting › Fire Pumps › Arrangement
Issued 4 May 2009
Resolved
Submit plan for modification made to firemain valve.
Action required: 705 - Other - as specified
Resolved 15 February 2017
Resolution: Modification plan submitted to inspector satisfaction.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 May 2009
Resolved
Verify tides table publication onboard prior to sea trials.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Provided current tide table for operating area.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 May 2009
Resolved
Conduct fire and man overboard drill during sea trials.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Both fire and man overboard drills conducted to inspector satisfaction.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 May 2009
Resolved
Properly label all lifejacket storage containers.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: All lifejacket storage containers properly labeled.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 4 May 2009
Resolved
Prove proper operation of navigation equipment.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Verified operation of nav equipment while underway for sea trials and drills.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 May 2009
Resolved
Conduct post dry-dock inspection in sync with annual COI.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Sea trials and annual COI inspections completed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 May 2009
Resolved
Conduct test for manual over-ride for pre-engineered system.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Manual over-ride test completed for engine and generator spaces to inspector satisfaction.
Fire Fighting › Fire Pumps › Power Source
Issued 4 May 2009
Resolved
Conduct test of fire pump during sea trials.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Verified operation of fire pumps.
Engineering › Steering Gear System › Pump
Issued 4 May 2009
Resolved
Verify operation of main steering gear system.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Operation of steering gear system verified.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 4 May 2009
Resolved
Verity operation of propulsion machinery.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Propulsion machinery operation verified to inspector satisfaction.
Engineering › Bilge Water Management System › Pump
Issued 4 May 2009
Resolved
Verify operation of bilge pump.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Bilge pump operation verified to inpector satisfaction.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 4 May 2009
Resolved
Verity operation of electrical equipment.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Electrical equipment operation verified to inspector satisfaction.
Fire Fighting › Nozzles › Number
Issued 28 July 2008
Resolved
Provide bronze nozzle for fire hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 31 July 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 July 2008
Resolved
Complete an Audit of drug and alcohol program for the company.
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 7 May 2009
Lifesaving › Lifefloat › Markings
Issued 26 April 2006
Resolved
Vessel name is faded needs to be repainted.
Due 26 May 2006
Resolved 17 May 2007
Resolution: Lifefloats are appropriately marked
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 April 2006
Resolved
Vessel name has faded on multiple lifejackets all need to ge gone through and restencil all faded ones.
Due 26 May 2006
Resolved 17 May 2007
Resolution: Lifejackets appropriately marked
Personnel › Training › First Aid/CPR
Issued 26 April 2006
Resolved
NO documentation that 50% of crew has had the required Fisrt aid/cpr cards.
Due 26 May 2006
Resolved 17 May 2007
Resolution: Proper CPR and First Aid Documentation presented during inspection
Electrical › Electrical Distribution System (service) › Cable
Issued 13 July 2004
Resolved
Replace commercial wire with approved marine grade cable for the air compressor.
Condition: Improper Installation
Due 14 August 2004
Resolved 23 August 2004
Resolution: Cable replaced with marine grade cable.
Lifesaving › Lifefloat › Lifeline
Issued 13 July 2004
Resolved
Replace lifeline on lifefloat.
Condition: Improper/Lack of Maintenance
Due 14 August 2004
Resolved 23 August 2004
Resolution: Life lines replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 13 July 2004
Resolved
Drydock must be completed prior to 30Jun05.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 29 June 2005
Resolution: Conducted drydock exam with no deficiencies.
Unknown
Issued 27 April 2001
Resolved
PROVIDE PROPER MAXIMUM UPPER DECK PASSENGER PLACARDING, MAXIMUM PASSENGERS ALLOWED IS FORTY (40) PER DECK AREA MEASUREMENTS.
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Engineering
Issued 27 April 2001
Resolved
RENEW PARTIALLY OBSTRUCTED PORT FUEL TANK VENT FLAME ARRESTOR.
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Engineering
Issued 27 April 2001
Resolved
PROVIDE/RENEW EMERGENCY FUEL SHUT-OFF VALVE MARKINGS IN ACCORDANCE WITH 46 CFR 185.608
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Engineering
Issued 15 May 2000
Resolved
COMPLETE EXHAUST LAGGING REPAIRS TO THE STBD ENGINE.
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Electrical › Electric Supply System (service) › Cable
Issued 15 May 2000
Resolved
REPLACE WIRES FOR THE ENGINE ROOM FIXED FIRE FIGHTING SYSTEM WITH APPROVED WIRES. IN PARTICULAR, THE ALRM/INDICATION WIRES RUNNING TO THE PILOT HSE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2000
Resolved 23 August 2004
Fire Fighting
Issued 9 November 1999
Resolved
VESSEL IS PROHIBITED FROM OPERATING WITH PASSENGERS UNTIL THE FOLLOWING REQUIREMENT IS COMPLETE: INSTALL A COAST GUARD APPROVED FIXED FIRE FIGHTING SYSTEM IN THE VESSEL'S ENGINE ROOM.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Construction/Loadline
Issued 24 May 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARMS IN THE ENGINE ROOM, GENERATOR ROOM, AND THESTEERING GEAR ROOM.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Lifesaving
Issued 24 May 1999
Resolved
PROVIDE AN FCC 406MHZ EPIRB. VESSEL LIMITED TO NO MORE THAN THREE (3) MILES FROM LAND.
Condition: Unknown
Due 24 June 1999
Resolved 28 May 1999
Fire Fighting
Issued 24 May 1999
Resolved
PROVIDE AN APPROVED FIXED FIRE FIGHTING SYSTEM IN THE ENGINE ROOM, OR PROVIDE PLANS ON THE EXISTING SYSTEM.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Lifesaving
Issued 11 May 1998
Resolved
STENCILE "DISTRESS" ON DISTRESS SIGNAL CONTAINER.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Electrical
Issued 11 May 1998
Resolved
SECURE THE STEERING COMPARTMENT LIGHT WIRE TO PREVENT RUBBING AGAINST THE BULKHEAD FRAME.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Lifesaving
Issued 11 May 1998
Resolved
PLACE A 3-6' LINE ON RING BUOY WATERLIGHT AND ATTACH TO RING BUOY.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Electrical
Issued 5 May 1997
Resolved
Repair aft starboard deck light.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 5 May 1997
Resolved
Properly mark distress signal container and color it with a bright color.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 5 May 1997
Resolved
Provide properly operating waterlight for the life float prior to the carriage of passengers at night or during restricted visibility.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Engineering
Issued 5 May 1997
Resolved
Replace port and starboard flexible fuel hose for main engines.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 5 May 1997
Resolved
Replace netting on life float with new material prior to carrying passengers.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 5 May 1997
Resolved
Properly mark and apply retroreflective material to unmarked life ring buoyprior to carrying passengers.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 26 August 1996
Resolved
Permanently install an ASME approved air receiver, with properly rated relief valve, in accordance with applicable Subchapter F regulations.
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Lifesaving
Issued 29 May 1996
Resolved
Provide 06 current red flares or 06 orange distress signals.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Construction/Loadline
Issued 29 May 1996
Resolved
Permanently install an ASME approved air receiver, with a properly rated relief valve, horn in accordance with applicable Subchapter F regulations.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Engineering
Issued 29 May 1996
Resolved
Properly install port side fuel 30x30 mesh vent screen.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Deck/Cargo
Issued 29 May 1996
Resolved
Permanently install proper guard for anchor windlass.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Navigation
Issued 29 May 1996
Resolved
Provide magnetic compass with current deviation table.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Electrical
Issued 29 May 1996
Resolved
Provide proper legend for main breaker panel.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Lifesaving
Issued 29 May 1996
Resolved
Replace waterlight batteries and provide proper length for waterlight lanyard.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Engineering
Issued 29 May 1996
Resolved
Properly install new rubber coupling hoses in raw water overboards on port and starboard engines.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Electrical
Issued 10 May 1995
Resolved
Secure all wire runs in engine space with metal fasteners.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Lifesaving
Issued 10 May 1995
Resolved
Restencil vessel's name on 2 lifefloat paddles.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Lifesaving
Issued 10 May 1995
Resolved
Provide working waterlight for lifefloat prior to nighttime operation._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Lifesaving
Issued 10 May 1995
Resolved
Install new life lines and painters on life float and ring buoys.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Navigation
Issued 10 May 1995
Resolved
Provide corrected and up to date navigation charts.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Engineering
Issued 10 May 1995
Resolved
Install machinery guards on the front of the port and starboard main dieselengines.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Construction/Loadline
Issued 4 May 1994
Resolved
RENEW RUBBER GASKET ON WATERTIGHT DOOR BETWEEN ENGINE ROOM AND HOLD.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994
Resolved
PROPERLY STENCIL 25 MAN LIFEFLOAT AND ITS EQUIPMENT.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Fire Fighting
Issued 4 May 1994
Resolved
PROVE ANNUAL SERVICING OF FIXED HALON EXTINGUISHER IN ENGINE ROOM.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Navigation
Issued 4 May 1994
Resolved
PROVIDE CURRENT CHARTS AND PUBS.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Electrical
Issued 20 May 1991
Resolved
REPAIR OR RENEW FREQUENCY METER FOR SHIP SERVICE GENERATOR.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Engineering
Issued 20 May 1991
Resolved
RENEW PORT FORWARD FLAME SCREEN ON FUEL TANK VENT.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Lifesaving
Issued 2 May 1990
Resolved
RENEW THE GRAB LINE AND PENDANTS ON THE BUOYANT APPARATUS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Fire Fighting
Issued 2 May 1990
Resolved
PROVIDE TWO USCG-APPROVED MARINE TYPE B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990
Resolved
PROVIDE MECHANICAL INTERLOCK TO PREVENT PUTTING SHORE POWER BREAKER AND SHIP SERVICE BREAKER ON AT THE SAME TIME.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 8 May 1989
Resolved
INSTALL VENTILATION IN THE FORE PEAK AND LAZARETTE NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Engineering
Issued 8 May 1989
Resolved
INSTALL SAFETY GUARDS OVER THE PORT AND STARBOARD SHAFTS NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Navigation
Issued 22 May 1987
Resolved
REPLACE, REPAIR OR REMOVE INOPERATIVE RADAR NO LATER THAN 22 JUNE 1987.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Engineering
Issued 19 April 1986
Resolved
INSTALL INSULATION ON BOTH MAIN ENGINE EXHAUST TO COOLING WATER CONNECTIONSPRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 19 April 1986
Resolved 19 April 1986
Engineering
Issued 19 April 1986
Resolved
INSTALL FLAME SCREEN ON PORT FUEL TANK VENT, PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 19 April 1986
Resolved 19 April 1986
Construction/Loadline
Issued 19 April 1986
Resolved
INSTALL HATCH COVER SECURING CHAIN ON AFT HATCH PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 19 April 1986
Resolved 19 April 1986