Records from 2013 to 2019. Most recent: inspection, 8 July 2019.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 June 2019
No resolution recorded
Dry Dock and ISE is overdue
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 April 2019
No resolution recorded
Vessels Hull/ISE exam is overdue by 6 months. A 835 was issued stating that the vessel needs a credit Hull/ISE exam prior to taking passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2018
No resolution recorded
provide safety certificate.
Action required: 705 - Other - as specified
Due 22 June 2018 — due date passed with no resolution recorded
Documentation › Certificates/Documents › FCC SSL
Issued 22 May 2018
No resolution recorded
provide safety station license
Action required: 705 - Other - as specified
Due 22 June 2018 — due date passed with no resolution recorded
Engineering › Lubricating Oil Service System › Gauge
Issued 22 May 2018
Resolved
Prove proper operation of MDE oil pressure gauge at operating station.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
Resolution: Guage repaired.
Navigation › Piloting/Steering › Marine Charts
Issued 22 May 2018
Resolved
Provide updated charts of the area.
Due 22 June 2018
Resolved 20 June 2018
Resolution: Charts updated.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 22 May 2018
Resolved
Provide notice to mariners.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 22 June 2018
Resolution: Notice to mariners updated.
Electrical › Electric Supply System (service) › Cable
Issued 22 May 2018
Resolved
Remove deadend wires on junction box aft of the pilot house.
Due 22 June 2018
Resolved 20 June 2018
Resolution: Wires removed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 May 2018
Resolved
Make proper repairs to the junction box on the second deck. Box rusted out.
Due 22 June 2018
Resolved 20 June 2018
Resolution: Junction box repaired.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 May 2018
Resolved
Repair fuel line between fuel cross over between the main fuel tanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 17 July 2018
Resolution: Fuel cross over installed
Engineering › Fuel Oil Service System › Hose
Issued 22 May 2018
Resolved
Repair replace fuel suppy line and fuel return line on generator.
Due 22 June 2018
Resolved 20 June 2018
Resolution: Hoses replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 May 2018
Resolved
Repair rail stanchion
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 17 July 2018
Resolution: rail stanchion repaired
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 May 2018
Resolved
Replace 24 adult and 1 child type I lifejackets.
Due 22 June 2018
Resolved 22 May 2018
Resolution: Lifejackets replaced.
Engineering › Bilge Water Management System › Piping
Issued 25 May 2017
Resolved
repair fore peak piping. crack in elbow.
Condition: Improper/Lack of Maintenance
Due 25 May 2017
Resolved 2 June 2017
Resolution: Tested Bilge suction.
Engineering › Steering Gear System › Piping
Issued 19 May 2017
Resolved
Repair hydraulic hose on steering ram.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: hose repaired.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 19 May 2017
Resolved
Repair dryrot on sewage hoses in transome
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Sighted new hose
Engineering › Bilge Water Management System › Valve
Issued 19 May 2017
Resolved
Repair/service deck drain valve Portside in transome.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: repaired
Engineering › Bilge Water Management System › Valve
Issued 19 May 2017
Resolved
Repair/service valve for bilge suction in fore peak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: valve repaired.
Engineering › Bilge Water Management System › Manifold
Issued 19 May 2017
Resolved
Repair/service valve on manifold #5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: valve repaired.
Fire Fighting › Fire Pumps › Casing
Issued 19 May 2017
Resolved
Repair/replace dryrot on hoses on fire pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: hoses replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 19 May 2017
Resolved
Install retro tape on upper deck life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Sighted new tape
Operations/Management › Passenger Operations › Safety Orientation
Issued 19 May 2017
Resolved
INSTALL ON DOCK PASSENGER COUNT BOX.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Life Jacket locker labled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2017
Resolved
Install RFI first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: installed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 May 2017
Resolved
Repair open light socket in pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 May 2017
Resolution: installed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 May 2017
Resolved
Secure benches on upper deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Benches secured.
Construction/Loadline › Structures › Superstructure
Issued 19 May 2017
Resolved
Replace Rot wood STBD head upper deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Wood replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 May 2017
Resolved
Replace rot wood on taft rail STBD and PORT side aft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Taft rail repaired
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 19 May 2017
Resolved
STBD wire course attachement point AFT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Life line attached.
Communications › Public Address System › Loudspeaker
Issued 19 May 2017
Resolved
Install/repair PA system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Tested PA
Construction/Loadline › Structures › Deck Plating
Issued 7 November 2016
Resolved
Repair / replace the rotted section of the 3rd deck beam from the aft door way port side for the 2nd deck.
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: Beam repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 10 August 2016
No resolution recorded
Remove the sewage tanks in the laz so the framing can be inspected.
Action required: 705 - Other - as specified