EAGLE

EAGLE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 2016, most recently in June 2026, along with 83 deficiencies — 2 with no resolution recorded — and 23 casualty investigations between 2002 and 2025.

Records from 2002 to 2026. Most recent: inspection, 9 June 2026.

Built
1987
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 June 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8705864
WCX5125
295658
Flag
UNITED STATES
Maury page id
psix-295658

Documentation record

Registered dimensions (L × B × D)218.7 ft × 60.0 ft × 16.0 ft
Registered tonnagegross 397 / net 270
ITC dimensions (L × B × D)218.7 ft × 60.0 ft × 16.0 ft
ITC tonnagegross 3,269 / net 1,389
BuilderMCDERMOTT SHIPYARD · AMELIA, LA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3269 - Convention (Subpart B), Gross Ton
397 - Regulatory (Subpart C or D), Gross Ton
1389 - Convention (Subpart B), Net Ton
270 - Regulatory (Subpart C or D), Net Ton
522 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

80 inspections, each with its date, unit and type; 83 deficiencies with the resolution recorded against each; 23 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 80

9 June 2026 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8395660
20 March 2026 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8329259
2 December 2025 COI Inspection · Examination of Repairs · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8276942
11 July 2025 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8183305
7 May 2025 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8130857
9 April 2025 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8109362
5 April 2025 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 8158480
7 March 2025 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090289
20 December 2024 Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8049802
28 October 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8022995
11 July 2024 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7955856
25 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7919109
17 May 2024 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7914207
16 May 2024 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7913389
16 May 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8022999
10 May 2024 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7909942
11 April 2024 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7893603
25 March 2024 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7885238
16 February 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7866472
30 November 2023 Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7820903
3 October 2023 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7803211
27 September 2023 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7803190
16 June 2023 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7709368
1 June 2023 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7704469
28 October 2022 COI Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs · In-Service Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7583318
24 October 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7557280
22 September 2022 Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7564289
2 September 2022 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7549598
31 May 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7459655
24 April 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7437392
24 April 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7846898
28 March 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7431850
29 December 2021 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7373853
29 December 2021 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7374580
7 December 2021 COI Inspection · MTSA Verification · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7352093
21 July 2021 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7263019
5 July 2021 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7256006
3 July 2021 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7255978
8 April 2021 MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7170837
4 January 2021 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7095945
29 October 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7086988
4 September 2020 Periodic Inspection · DAPI Audit · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7052910
17 August 2020 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7035150
17 August 2020 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7035828
4 June 2020 Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6977107
13 May 2020 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6952498
28 April 2020 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6945183
14 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855841
31 October 2019 Examination of Repairs · In-Service Inspection · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6846248
13 September 2019 DAPI Audit · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6810977
3 July 2019 In-Service Inspection · MTSA Verification · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6728633
26 June 2019 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6726168
10 March 2019 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6640330
10 March 2019 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6645279
2 March 2019 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6654357
18 December 2018 DAPI Audit · COI Inspection · Deficiency Check · Examination of Repairs · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6599798
8 November 2018 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6578148
3 October 2018 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6557496
3 October 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6562351
20 June 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6451235
11 June 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6441475
8 June 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6444346
6 June 2018 MTSA Verification · DAPI Audit · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6431268
1 June 2018 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6431566
23 February 2018 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6366289
23 February 2018 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6367766
9 February 2018 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6352599
6 December 2017 COI Inspection · MTSA Verification · DAPI Audit · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6308122
22 November 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6311580
23 October 2017 In-Service Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6291725
27 September 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6276576
26 June 2017 DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6189701
15 March 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6105458
4 January 2017 In-Service Inspection · DAPI Audit · COI Inspection · MTSA Verification · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6065618
26 October 2016 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6030169
7 July 2016 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5941423
1 April 2016 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5845518
31 March 2016 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5845525
7 March 2016 Examination of Repairs · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5814221
19 January 2016 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5800947

Deficiency record · 83

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2025 Resolved
Vessel had a cracked weld in the side shell/deck seam on the stern where the vessel allided with the mooring dolphin. The crack was on the inside of the vessel only. No day light could be seen from inside the steering void. Crack was repaired by a certified welder and inspected by the attending MI.
Action required: 10 - Deficiency Rectified
Due 9 April 2025
Resolved 9 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2025 No resolution recorded
Cylinders shall be so installed as to provide a space of at least 2 inches between the flooring and the bottom of the cylinders. The fixed fire extinguishing cylinders are not raised 2" off the deck. Have servicing agent raise & inspect cylinders and provide tech report to CG marine inspector. Vessel has till no later than next drydock to properly install cylinders. Cylinders are to be inspected within the next 30 days and then annually till correction is made.
Action required: 705 - Other - as specified
Due 31 December 2027
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 December 2024 No resolution recorded
Cylinders shall be so installed as to provide a space of at least 2 inches between the flooring and the bottom of the cylinders. The fixed fire extinguishing cylinders are not raised 2" off the deck. Have servicing agent raise & inspect cylinders and provide tech report to CG marine inspector. Vessel has till no later than next drydock to properly install cylinders. Cylinders are to be inspected within the next 30 days and then annually till correction is made.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 May 2024 Resolved
All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Vessel reported excessive smoke coming from the stack of the number one generator. The number three generator is tagged out from a previous casualty, and there are insufficient generators to continue operations. Repair the Number one or number three generator to the satisfaction of the Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2024
Resolved 26 May 2024
Resolution: See Activity Number 7919109
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 May 2024 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship’s service load under normal operational conditions. #3 SSDG stalled and could not be re-started. Prove proper operation of #3 SSDG to the satisfaction of the attending USCG MI prior to placing back into service.
Action required: 705 - Other - as specified
Due 16 May 2024
Resolved 16 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2024 Resolved
Emergency generator must supply emergency loads that may be necessary to maintain or restore the propulsion plant, such as control systems, controllable pitch propellers, hydraulic pumps, control air compressors, and machinery necessary for dead-ship start-up. Vessel lost propulsion controls after vessel lost #3 SSDG and went darken ship, vessel did not regain propulsion controls when emergency generator started and provided emergency power. Prove proper operation of propulsion controls during loss of ships power and while under emergency power to the satisfaction of the attending USCG MI prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 16 May 2024
Resolved 16 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 May 2024 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time a defect is discovered. Vessels bow thruster was leaking and needed a seal replacement. CGMI to inspect repairs prior to the vessel returning to passenger service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Repairs completed and inspected by CGMI.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 December 2022 Resolved
Update Fire Control Plan to reflect fire detection system installation and submit to local OCMI for review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2023
Resolved 20 January 2023
Resolution: Plan approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 September 2022 Resolved
The fuel connection from the portable fuel tank to the outboard engine on the rescue boat had an active fuel leak. fuel was collecting on the deck of the rescue boat. Leak was able to be stopped by opening the fuel tank vent. Fitting from fuel line to the portable tank shall be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2022
Resolution: Received photo of the fuel tank with the new fitting
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 September 2022 Resolved
Fire door on the 3rd deck aft on the stbd side in vicinity of the food service area would not self close or latch. The door is equipped with a crash bar and is located in a a fire boundary. Adjust the door or replace the crash bar to ensure the fire door self closes and latches shut.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2022
Resolution: Received a video of the door closing and latching
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2022 Resolved
A ground fault is being indicated on the main electrical panel. Ground fault needs to be isolated and repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2022
Resolved 24 October 2022
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2022 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operating conditions. Vessel reported that the #3 generator & switchboard is not operational. Effect repairs prior to running the #3 generator or it's switchboard to the satisfaction of the attending CG marine inspector. 46 CFR 111.10-4(d), Code 705C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 5 October 2022
Resolution: Witnessed an operational test of the generator in parallel with the #2 generator as well as the reverse power relay tripping and putting the full electrical load on the #3 generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2022 Resolved
POWER OPERATED MAIN AND AUX STEERING GEAR MUST BE SEPERATE / INDEPENDENT SYSTEMS; Vessel reported loss of steering from bridge console on the #2 pump. Identified issue to be potentiometer in steering console. 46 CFR 58.25-10(b)(1).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2022
Resolved 24 April 2022
Resolution: Crew replaced part in kind; satisfactory sea trial tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 December 2021 Resolved
Shaft seal on the bow thruster discharged oil into a navigable waterway of the U.S. Lockout/tag out bow thruster till proper repairs are made to the satisfaction of CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2022
Resolved 14 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 July 2021 Resolved
Vessel reported inoperable bow thruster due to a failure of the starter on the prime mover. Vessel is directed to make reapirs & prove satisfactory operation to the CG prior to departure. 46 CFR 70.20-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2021
Resolved 5 July 2021
Resolution: Vessel replaced starter in kind, proved satisfactory start/operation of the bow thruster.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 3 July 2021 Resolved
Each vessel must have a gyrocompass. Vessel is required to make repairs and prove satisfactory operation of the gyro compass by 07 July 2021. 33 CFR 164.35(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2021
Resolved 4 July 2021
Resolution: Vessel replaced gyro in kind, proved satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 January 2021 Resolved
Pipe leading to fire station #26 (03 deck stbd side) has hole. Replace and test at operational pressure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2021
Resolved 12 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 January 2021 Resolved
Fire door not properly latching (01 deck stbd side frame 43). Ensure door latches properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2021
Resolved 11 January 2021
Resolution: Door adjusted and properly latches upon closure.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2021 Resolved
Install fire extinguisher on rescue boat. Currently, none onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2021
Resolved 8 April 2021
Resolution: Extiguisher has been installed on the rescue boat.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 11 January 2021 Resolved
Make repairs to #1 boiler and test to satisfaction of attending USCG marine inspector prior to placing into service.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 February 2021
Resolved 11 August 2021
Resolution: Boiler has been repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 August 2020 Resolved
The system shall be arranged that the overhead is effectively sprayed and all portions of the deck are covered. Piping to port mid section of sprinkler system is damaged preventing waterflow. Repair and test system to the satisfaction of attending Marine Inspector. No cargo is allowed on port mid section.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2020
Resolution: Piping replaced in-kind. System tested. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2020 Resolved
Replace fuel pressure safety switch and test to the satisfaction of the attending USCG Marine Inspector prior to placing the #1 boiler into service.
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 11 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2020 Resolved
Update PSTPs and submit to local OCMI for review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2020
Resolved 25 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2020 Resolved
Recently submitted AC one line dwg is to be updated and re-submitted to MSC for review and approval along with and updated load analysis. A spot check verification of pages 17 and 19 was conducted utilizing the latest revision of the AC one line dwg. The dwg does not reflect what is installed, ie AC one line shows systems installed such as marine sanitation devices that are no longer existent, sewage pumps, salt water sanitation pumps, etc. In addition, some systems that are installed are not on the AC one line dwg.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2020
Resolved 12 August 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 13 December 2019 Resolved
Install general alarm bell in bow thruster space. Must be on emergency circuit.
Action required: 705 - Other - as specified
Due 1 October 2020
Resolved 4 January 2021
Resolution: General alarm installed in bow thruster space.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2019 Resolved
Install low oil pressure alarm on the reduction gears.
Action required: 705 - Other - as specified
Due 1 October 2020
Resolved 11 January 2021
Resolution: Prior to credit drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 December 2019 Resolved
Calibrate fuel tank gages in the EOS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2020
Resolved 11 January 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 December 2019 Resolved
Address the excessive wastage in the AMR plenum to the satisfaction of the attending USCG Marine Inspector or provide repair proposal to OCMI if extension of repairs is requested for next drydock fall of 2020.
Action required: 705 - Other - as specified
Due 1 October 2020
Resolved 17 November 2020
Resolution: Prior to credit drydock fall 2020.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019 Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 September 2019 Resolved
Vessel's 6 orange hand flares are expired.
Condition: Invalid
Due 20 September 2019
Resolved 24 September 2019
Resolution: Vessel purchased new orange hand flares.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 September 2019 Resolved
Excessive bilge oil under the #2 SSDG must be cleaned up and oil leaks investigated.
Condition: Invalid
Due 20 September 2019
Resolved 24 September 2019
Resolution: Vessel removed oily bilge water, found source & tightened connection.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 September 2019 Resolved
PA syatem is inaudible in certain points throughout the vessel. Troubleshoot entire PA system to ensure appropriate volume in all areas.
Condition: Invalid
Due 20 September 2019
Resolved 24 September 2019
Resolution: Vessel had a technician come out and investigate the inaudible speakers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2019 Resolved
Lifejacket stowage signage on stern & aft of pilothouse is worn and illegible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: Vessel replaced signage with new stickers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2019 Resolved
Coolant coupling on EDG is leaking and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: Vessel replaced the coupling in question.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 September 2019 Resolved
Conduct drills with a focus on communication. Drills conducted had poor communication which led to a breakdown in the accomplishment of the drills.
Condition: Invalid
Due 20 September 2019
Resolved 24 September 2019
Resolution: Vessel conducted drills with a focus on communication.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2019 Resolved
Vessel's lockout/tagout procedures were not being properly followed.
Condition: Invalid
Due 20 September 2019
Resolved 24 September 2019
Resolution: Vessel properly implemented their lockout/tagout procedures onboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2019 Resolved
Engine room escape scuttle couldn't be opened from inside the engine space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
Resolution: Vessel successfully opened, greased and exercised the scuttle from inside the space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 June 2019 Resolved
Make permanent repairs to vessel's stern vehicle loading door to the satisfaction of the attending USCG Marine Inspector prior to 03Jul19.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2019
Resolved 28 June 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 March 2019 Resolved
Vessel shall c/r the damaged area while at Fairhaven ship yard. In addition, a CG Marine Inspector shall witness fit up, final weld and weld test (vacuum box or water test) prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2019
Resolved 30 March 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 March 2019 Resolved
Damage at FWD BOW/FWD Peak. Fractured weld has been welded and water tested.Temp repair has been made.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2019
Resolved 11 March 2019
Resolution: Temp repair has been made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 January 2019 Resolved
Resubmit USCG witnessed tests of DVTPs and PSTPs to the Marine Safety Center for final approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2019
Resolved 2 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2019 Resolved
Update electrical drawings to reflect the new installation of the MDE hot starts and submit to MSC for approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2019
Resolved 9 January 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2019 Resolved
Conduct security audit with VSO and USCG Marine Inspector. VSO was unfamilar with security plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2019
Resolved 24 January 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 January 2019 Resolved
Repair PA speakers / general alarm bells / emergency lighting / and label accordingly as discussed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 January 2019 Resolved
Identify purpose / label / and test the red alarm bell located outside of both elevators on the freight deck and/or remove.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2019
Resolution: Removed bells and cable dead ended in junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 December 2018 Resolved
Repair Tachometer on #2 SSDG
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 December 2018 Resolved
Repair emergency light in EDG space
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 December 2018 Resolved
Repair/replace port MDE exhaust expansion bellows, cracked with exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 December 2018 Resolved
Replace missing/torn down insulation in AUX machinery space IWO soft patch / IWO of new monorail installation in E/R / and IWO aft elevator on overhead on the freight deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 December 2018 Resolved
Repair ventilation/fire damper in EDG space
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 October 2018 Resolved
Pinhole leak at flex joint piping flange on the discharge side of the fire pump. Repair flex joint flange to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 June 2018 Resolved
Relabel aft portside lifering on passenger deck with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 8 June 2018
Resolution: Verified vessel stenciled vessel name on lifebuoy.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 June 2018 Resolved
Repair portside MES evacuation ligting in way of MES system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 8 June 2018
Resolution: Verified lights were fixed for portside MES.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 6 June 2018 Resolved
Reinstall MES lifesaving on stbd side.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2018
Resolved 14 June 2018
Resolution: Verified vessel's starboard side MES was reinstalled.
Engineering › Compressed Air System (control) › Valve
Issued 23 February 2018 Resolved
AIR DRYER AUTOMATIC DRAIN VALVE MALFUNCTIONED OPEN, RESULTED IN LOSS OF CONTROL AIR
Due 7 March 2018
Resolved 7 March 2018
Resolution: VALVE REPLACED IN KIND TO ORIGINAL.
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 8 January 2018 Resolved
Hydro test both Boilers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 9 February 2018
Resolution: Cleared by MSD CC.
Electrical › Electric Generation Source (service) › Switch
Issued 8 January 2018 Resolved
Repair the audible alarm for the overspeed shutdown on the #3 SSDG.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 6 June 2018
Resolution: Vessel was able to demonstrate overspeed visual/audible alarm and shutdown on the #3 SSDG.
Documentation › Certificates/Documents › Stability Letter
Issued 8 January 2018 Resolved
Submit stability calculations (weight addition of deck seating) to the USCG Marine Safety Center.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 1 June 2018
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 8 January 2018 Resolved
Deploy the starboard side MES by 23 April 2018
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018
Fire Fighting › Nozzles › Size
Issued 8 January 2018 Resolved
Replace the incorrect sized sprinkler head, port forward.
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 9 January 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 January 2018 Resolved
Conduct underway fire, man overboard, abandon ship and security drills.
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 9 February 2018
Resolution: Witnessed satisfactory drills.
Engineering › Bilge Water Management System › Piping
Issued 6 December 2017 Resolved
Prove proper operation of the bilge suctions in the forepeak and bow thruster compartments.
Due 8 January 2018
Resolved 9 January 2018
Resolution: Pipes were frozen due to extreme low temps.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 22 November 2017 Resolved
The vessel's EDG switchboard is not properly operating as designed. The switchboard has a bad/damage relay resulting in the EDG autostarting when not needed. Until the relay is replace, the vessel may leave the EDG in manual operation. Also, a crewmember shall be present to switch the EDG to the autostart function when the vessel is transiting from the sea buoy to the dock in both Hyannis and Nantucket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 24 November 2017
Resolution: Vessel replaced faulty relay for EDG switchboard.
Lifesaving › Launching Appliances › Davit
Issued 23 October 2017 Resolved
The vessel's rescue boat davit limit switch for the raising and lowering of the boat is not working properly. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2017
Resolved 23 October 2017
Resolution: Vessel was able to replace the limit switch.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 6 February 2017 Resolved
Port MDE; low oil pressure alarm not operational, retest prior to completion of COI.
Due 6 February 2017
Resolved 14 February 2017
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 6 February 2017 Resolved
Repair FSDs; 01-05, MD 06, 02-10, 02-14
Due 6 February 2017
Resolved 17 February 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 February 2017 Resolved
Replace expired medicine(s); e.g. amomonia inhalent.
Due 6 February 2017
Resolved 17 February 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 January 2017 Resolved
Conduct underway man overboard, fire and security drills.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 15 March 2017
Resolution: Vessel conducted drills satisfactory.
Stability › Incline Test › General
Issued 4 January 2017 Resolved
Submit stability calculations to the USCG MSC for the weight change and location of the new rescue boat.
Due 17 March 2017
Resolved 22 March 2017
Engineering › Steering Gear System › Ram
Issued 1 April 2016 Resolved
The Pin that connects the tiller to the steering ram broke free due to cracked welds.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2016
Resolved 1 April 2016
Resolution: SSA engineers welded new washer in place to secure pin from falling out. Conducted sea trial, all sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 March 2016 Resolved
Stbd side vehicle deck fwd lighting fixture not operational, repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 March 2016 Resolved
Stbd side vehicle deck emergency lighting fixture adjacent to engine room entrance is partially lit, repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Communications › Public Address System › Loudspeaker
Issued 7 March 2016 Resolved
Repair two PA speakers located above port side gangway door and stbd side aft on vehicle deck. Speakers not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 7 March 2016 Resolved
Light fixture located on vehicle deck at top of ladder port side fwd leading to 01 Deck is missing the globe. Replace globe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 March 2016 Resolved
Provide up to date charts and light list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Communications › Alarms/Indicators › General Alarm
Issued 7 March 2016 Resolved
Repair the following GA bells, Crews quarters, main deck aft IWO the elevator and open deck IWO the anchor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 March 2016 Resolved
Provide 15 additional adult life preservers, max allowable passengers is reduced to 784.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 18 March 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 March 2016 Resolved
Conduct man overboard, abandon ship, fire, and security drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 31 March 2016
Resolution: Conducted satisfactory crew drills.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 March 2016 Resolved
Low oil pressure alarm on the emergency generator is not functioning. Demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2016
Resolved 18 March 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 29 February 2016 Resolved
Remove electrical wiring associated with decommisioned grey water tank level indicator.
Due 29 March 2016
Resolved 18 March 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 29 February 2016 Resolved
Remove dead ended electrical cable in bow thruster space.
Due 29 March 2016
Resolved 14 March 2016
Engineering › Bilge Water Management System › Strainer
Issued 29 February 2016 Resolved
Provide strainers for aux machinery space and fore peak bilge suctions.
Due 7 March 2016
Resolved 14 March 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 19 January 2016 Resolved
Remove piping associated with decommissioned grey water tank.
Due 29 March 2016
Resolved 6 February 2017
Resolution: Two pipes at the bottom of grey water tank are not capped off, but do not pose a hazard to progressive flooding as the tank is contained well in between the watertight bulkheads fore and aft. All other associated piping has been blanked off.

Casualty record · 23

1 May 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1778554
23 April 2005Routine · role: Involved in a Marine Casualty · activity 2343934
15 September 2005Routine · role: Involved in a Marine Casualty · activity 2493072
17 March 2008Routine · role: Involved in a Marine Casualty · activity 3180470
19 November 2008Routine · role: Involved in a Marine Casualty · activity 3413372
15 September 2009Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 3596542
15 September 2009Routine · role: Involved in a Marine Casualty · activity 3596556
17 September 2011Routine · role: Involved in a Marine Casualty · activity 4293055
27 September 2011Routine · role: Involved in a Marine Casualty · activity 4160682
4 October 2011Routine · role: Involved in a Marine Casualty · activity 4162967
23 May 2012Routine · role: Involved in a Marine Casualty · activity 4336654
13 July 2012Routine · role: Involved in a Marine Casualty · activity 4380631
14 October 2012Routine · role: Involved in a Marine Casualty · activity 4464153
17 May 2013Routine · role: Involved in a Marine Casualty · activity 4594007
25 July 2013Routine · role: Involved in a Marine Casualty · activity 4664064
23 February 2018Routine · role: Involved in a Marine Casualty · activity 6366289
3 October 2018Routine · role: Involved in a Marine Casualty · activity 6562351
10 March 2019Routine · role: Involved in a Marine Casualty · activity 6645279
17 August 2020Routine · role: Involved in a Marine Casualty · activity 7035828
29 December 2021Routine · role: Involved in a Marine Casualty · activity 7374580
24 April 2022Routine · role: Involved in a Marine Casualty · activity 7846898
16 May 2024Routine · role: Involved in a Marine Casualty · activity 8022999
5 April 2025Routine · role: Involved in a Marine Casualty · activity 8158480
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.