Records from 1985 to 2026. Most recent: inspection, 9 April 2026.
Inspection history · 221
9 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8345352
13 March 2026
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8324570
14 October 2025
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8251603
12 June 2025
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8157743
25 February 2025
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8078837
16 December 2024
In-Service Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8057034
28 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8010853
11 September 2024
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8000065
4 April 2024
Examination of Repairs · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7881948
7 November 2023
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7821498
11 September 2023
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7789575
24 May 2023
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7713226
24 March 2023
Administrative Inspection · Deficiency Check · COI Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7651793
10 August 2022
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7531451
27 July 2022
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7517939
17 May 2022
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7452884
17 May 2022
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7875754
7 April 2022
Examination of Repairs · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7422798
1 February 2022
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7388852
8 September 2021
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7309478
25 August 2021
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7296608
21 May 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7202718
13 May 2021
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7183809
9 March 2021
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7152026
10 October 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7077176
17 June 2020
Examination of Repairs · COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6978286
14 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855826
22 October 2019
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6840878
24 September 2019
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6830362
24 September 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6831628
24 September 2019
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6862380
17 September 2019
DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6810970
13 August 2019
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6782043
19 July 2019
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6794789
28 May 2019
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6702573
28 May 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6727439
3 May 2019
Examination of Repairs · DAPI Audit · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6677800
15 November 2018
Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6582010
28 August 2018
MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6521643
8 July 2018
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6473069
12 June 2018
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6442169
31 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6423326
24 April 2018
MTSA Verification · Examination of Repairs · COI Inspection · DAPI Audit · Deadweight Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6399350
27 October 2017
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6298493
4 October 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6277754
27 September 2017
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6295013
13 July 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6207689
21 June 2017
In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6177730
2 June 2017
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6163842
2 June 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6200069
24 April 2017
DAPI Audit · Examination of Repairs · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6132384
31 January 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6080363
24 January 2017
Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6079522
16 September 2016
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6004033
9 September 2016
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5999438
9 September 2016
Plan Review (Other than "T")
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6006047
6 July 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5931975
6 July 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5940514
9 June 2016
Deficiency Check · MTSA Verification · DAPI Audit · Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5922651
27 May 2016
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888696
27 May 2016
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5934234
28 April 2016
MTSA Verification · COI Inspection · DAPI Audit · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5864986
29 October 2015
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5751141
22 September 2015
Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5727461
28 August 2015
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5228856
21 May 2014
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4865600
26 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4357484
9 December 2011
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4205167
7 February 2011
Examination of Repairs · Deadweight Survey · Plan Review (Other than "T")
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3940593
23 November 2010
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3897649
5 October 2010
Examination of Repairs · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3868860
1 October 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3862826
1 October 2010
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3864361
30 July 2009
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3551636
7 May 2009
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3472945
1 May 2009
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3458179
23 March 2009
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3439334
3 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3426883
22 September 2008
Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3317506
19 June 2008
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3219355
19 March 2008
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3157901
13 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3163517
30 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3089904
1 October 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3252583
21 March 2007
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2891840
26 September 2006
Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2786594
12 September 2006
MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2777101
12 September 2006
MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2784678
12 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2710717
14 June 2006
Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2657443
5 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2671131
9 May 2006
Deficiency Check · COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2601356
21 February 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2589274
1 September 2005
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2481795
28 July 2005
Damage Survey · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2443744
18 July 2005
MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2427964
19 May 2005
Re-Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2361708
25 March 2005
Deficiency Check · COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2318547
10 November 2004
MTSA Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2239709
2 September 2004
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2183621
11 June 2004
Administrative Inspection
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2095509
18 May 2004
Damage Survey
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2073312
18 May 2004
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2076652
18 May 2004
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2350670
12 May 2004
COI Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2064556
13 February 2004
Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2011287
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977613
20 October 2003
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1932236
22 September 2003
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1908565
4 June 2003
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1809357
5 May 2003
COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1786708
7 October 2002
Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1686638
6 July 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1684000
9 May 2002
COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1614656
3 April 2002
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1598082
22 March 2002
Permit to Proceed
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1496061
4 October 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1074720
28 September 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1457994
2 February 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1430965
20 March 2000
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1047468
29 October 1999
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1130037
12 October 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1448020
8 April 1999
Inclining Experiment
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 787403
7 April 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 3819
5 April 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799607
5 April 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799901
5 April 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415285
5 March 1999
Deadweight Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1365094
30 September 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 801364
20 September 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 146020
20 June 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 22413
17 June 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 170396
10 March 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 98584
3 March 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1116920
27 February 1998
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1119665
10 July 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1116273
8 May 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1099887
5 February 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1446454
4 February 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103762
21 October 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848091
9 October 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150691
18 September 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133000
17 July 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 118571
15 July 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 23520
13 May 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1472508
1 May 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 59872
1 May 1996
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1414632
28 February 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 134971
26 February 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 131934
26 February 1996
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1371310
6 February 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882204
5 January 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1355652
7 October 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 187931
20 May 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 219452
4 February 1995
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154156
31 October 1994
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173492
8 September 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1179874
23 March 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 133178
3 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165269
24 February 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165088
2 February 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 30056
11 January 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 850365
7 January 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160660
10 December 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159790
15 November 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159575
26 October 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1139112
16 September 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149958
15 September 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144568
19 August 1993
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156865
2 August 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842831
10 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834443
25 February 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834922
24 February 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932790
31 December 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831870
30 December 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961072
25 November 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 143241
25 November 1992
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832688
23 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945927
20 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 173041
16 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 72858
16 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945473
13 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949571
4 August 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 186367
4 August 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263800
7 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 97580
26 February 1992
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263691
27 June 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935625
24 June 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249934
18 April 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942800
27 February 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242762
21 December 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233274
24 September 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242152
1 September 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1224875
13 July 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211357
12 February 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231264
4 January 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241133
22 December 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235399
12 December 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1238263
8 November 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922492
5 June 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196023
3 January 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040376
8 December 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 898503
17 November 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893535
20 June 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1205618
29 January 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324097
9 December 1987
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002423
3 December 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308091
8 October 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320006
5 December 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022646
1 October 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005555
29 September 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005762
8 September 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005760
2 July 1986
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998888
14 April 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999530
22 February 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294645
4 January 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996841
15 October 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301777
1 October 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994005
26 September 1985
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299093
17 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984282
18 March 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1282090
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 March 2026
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Vessel did not complete a MOB and Fire Drill during their COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2026
Resolved 9 April 2026
Resolution: Vessel is being sold. Vessel is off the run
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2025
Resolved
Spaces which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on board while the vessel is being navigated shall be fitted with an approved audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. Alarm was broken, prove proper operation of CO2 siren behind the ladder in the vidmar space prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2025
Resolved 10 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2025
Resolved
All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance
with NFPA 10. Provide fire fighting servicing certificates prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2025
Resolved 10 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 25 February 2025
Resolved
Information required for the fire control plan shall be kept up-to-date, any alteration being recorded in the applicable medium as soon as practicable. Update fire control plan and submit to local OCMI for review and approval prior to 06Apr25.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2025
Resolved 21 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2024
Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter. Vessel reported that the #2 Generator has a jacket water leak. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2024
Resolved 4 October 2024
Resolution: See Activity Number 8010853.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 September 2024
Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that—
(a) Illustrate the purpose of controls;
(b) Illustrate the procedures for operating the launching device;
(c) Give relevant instructions or warnings;
The vessel's life raft launching procedures that are posted do not match or work as instructed with the installed raft mount. Correct posted instructions to provide clear direction.
46CFR 199.90
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 3 October 2024
Resolution: renewed postings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2024
Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. The lifebuoy, mid-deck has clear opening in shell exposing core foam. Provided buoy that is secure from water penetration.
46CFR 199.70.a.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 3 October 2024
Resolution: renewed ring.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 September 2024
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire; ...The lower fire vent closure, as identified has a hole in the closure. Provide a closure that meets the
structural requirements of the installed bulkhead.
46CFR 72.05-50
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 25 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 September 2024
Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0, or C, depending upon the type of space on each side of the bulkhead or above and below the deck. The engine control room is missing various cutouts of the once installed fire insulation. Vessel to provide boundary IAW the bulkhead tables contained in 46 CFR 72.05-12 to the satisfaction of the attending USCG MI.
46CFR 72.05-50
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 25 February 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 September 2023
Resolved
An MMC, license, MMD, COR, or STCW endorsement must be retained by the mariner to whom it was issued and, while valid, must be produced to verify qualifications when requested by an authorized official as identified in 33 CFR 101.515(d). Posting of the officer endorsement may be necessary as required in 46 U.S.C. 7110. The vessel Chief Engineer was unable to produce an MMC. Vessel was able to locate a properly credentialed Chief Engineer to take over operations over crew change-out.
46 CFR 10.203(b)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 11 September 2023
Resolved 11 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 March 2023
Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation. Vessel is outfitted with fixed concrete ballast at either end of the vessel, that is not accounted for on the stability letter. This additional fixed ballast invalidates the stability letter. Prior to returning to service, submit locations, weights and dates that the concrete was installed to the Marine Safety Center and this office.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2023
Resolved 11 May 2023
Resolution: Vessel received updated stability letter from MSC.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2023
Resolved
In a passenger vessel no oil level gauge sight glasses may require penetration below the top of the tank, and neither the failure of a gauge nor an overfilling of the tank may permit release of fuel into the space. Remove/replace fuel oil day tank sight glass in forward storage room with an approved gauging system.
Action required: 705 - Other - as specified
Due 17 June 2023
Resolved 4 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 24 March 2023
Resolved
Submit corrected fire control plan to the local OCMI for review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 10 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2022
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs, or a defect is discovered with affects the safety of the vessel. Vessels bow engine experienced loss of propulsion on approach to company dock in Woods Hole Massachusetts. Effect repairs as necessary and demonstrate satisfactory operation to the satisfaction of the attending Marine Inspector. 46CFR71.40-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022
Resolved 19 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2021
Resolved
A survey, either general or partial shall be made every time a defect is discovered which affects the safety of the vessel. Vessel reported the forward engine shut down due to low oil pressure during approach to dock. Prior to carrying passengers, Determine the cause of engine shut down, repair, and conduct a sea trial to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2021
Resolved 25 August 2021
Resolution: See Activity Number 7296608
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2021
Resolved
Repair closure device on the door between passenger and crew accomodation area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 7 June 2021
Resolution: Confirmed new closure has been installed on door between passenger and crew accommmodation area that is fully functional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2021
Resolved
Provide boiler servicing report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 17 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 May 2021
Resolved
Mark emergency escape hatches for the machinery spaces and direction to turn to open.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 7 June 2021
Resolution: Confirmed appropriate signage for emergency escape has been appropriately installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2021
Resolved
Make corrections to June 2020 PSTPs, re-test and verify all test procedures are correct. Submit corrected PSTPs to local OCMI after procedures are verified.
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 13 May 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 May 2021
Resolved
Submit weight change calculations to Marine Safety Center for approval for new mast installations for current stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 21 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 13 May 2021
Resolved
Renew grating btm of ladder of the aft steering machinery room, grating is rotted out and poses a danger to personnel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019
Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
Make permanent repairs to steering system and test to the satisfaction of the attending USCG Marine Inspector prior to carrage of passengers/cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2019
Resolved 24 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
Tube transmission cooler failure. Repair / replace cooler.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2019
Resolved 25 November 2019
Resolution: Repair made to cooler tube bundle, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2019
Resolved
Wirenuts on batteries, Woods Hole end (Motor room 2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 3 October 2019
Resolution: Vessel Installed proper nuts on the batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2019
Resolved
MDE has saltwater leak on the after end onf the engine. Investigate leak. Motor room 1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 8 October 2019
Resolution: Vessel engineer rectified issue.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 September 2019
Resolved
gasket on EDG room is wasted. replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Gasket has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2019
Resolved
Investigate heavy dust particles located on MDE turbo in motor room 2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel crew determined the dust was from in the intake exhaust system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2019
Resolved
#1 MDE derating on alarm codes. Repair and prove proper operation of #1 MDE prior to carriage of passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 May 2019
Resolved
Revise and correct fire control plan as discussed with [name withheld] revised plan to local OCMI for review. Obtain local plan approval prior to 22Jun19.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2019
Resolved 1 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 May 2019
Resolved
Obtain MSC plan approval for MSCORP dwg No. 3233-84-14 "180V/120V electrical mods incidental generator replacement" and IEM Marine Job No. 180-104677 "Main Switchboard" prior to 30Jun2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 17 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2019
Resolved
Submit revised MSCorp dwg No. 3233-84-14 "480V/120V electrical mods incidental generator replacement" and IEM Marine Job No. 180-104677 "Main Switchboard" for MSC approval as noted in MSC ltr E2-1801766 dtd 14May2018 to address comments #4 and #9 and comment #4 on MSC ltr E2-1802082 dtd 13Jun2018.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
Resolution: Dwgs Submitted to MSC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2019
Resolved
Master PSTPs do not reflect testing actually performed on the vessel. Modify PSTPs and submit to local OCMI for approval, verification, and testing prior to next issuance of COI in 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 May 2021
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 3 May 2019
Resolved
Indicator lights not functioning. Repair indicator lights on the water tight doors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2019
Resolved
120 VAC Dist panel indicates a ground on Island Space Heating PL #2. Repair ground.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
Emergency lighting for rescue boat is inoperable. Repair emergency lighting for the rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
Emergency lights exterior of house on vehicle deck are not on the emgerency circuit. Repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
Resolution: Not required per Regulations and not installed IAW orginial electrical dwgs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 November 2018
Resolved
Revise A/C one line dwg, A/C load analysis, and Fault Current Analysis and Protective Device Coordination study to reflect as built and obtain plan approval from MSC.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 November 2018
Resolved
Crop and renew wasted through decking in crew cleaning locker on main deck to good metal or provide a written repair proposal to the OCMI for review and determination.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 26 November 2018
Resolved
Make vessel available for inspection for USCG verification and approval of Fire and Safety plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Provide Marine Safety Center (MSC) approved plans for references (d) and (g) noted in MSC ltr E2-1801766 dtd May 14, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Cleared and re-issued to submit revised plans to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Address comments # 2, 4, 5, and 9 in MSC ltr E2-1801766 dtd May 14, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Cleared and re-issued to submit revised plans to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Address comments #3 and #4 noted in MSC ltr E2-1802082 dtd June 13, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Cleared and re-issued to submit revised plans to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Provide copy of latest approved plans noted in reference (a) and (b) in MSC ltr E2-1802082 dtd June 13, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2018
Resolved
Cannon plug wires parted on the Woods Hole end transmission.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 July 2018
Resolved 29 August 2018
Resolution: Vessel repaired cannon plugs on the Woods Hole End transmission.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2018
Resolved
Throttle positioning sensor is actively going off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 July 2018
Resolved 29 August 2018
Resolution: Vessel repaired throttle positioning sensor.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 12 June 2018
Resolved
Fuel oil pressure alarm active on main diesel engine, repair / replace, prove propper operation of fuel system on main engine, prior to operations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 29 August 2018
Resolution: Vessel repaired fuel oil pressure alarm on main diesel engine.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 31 May 2018
Resolved
Mark area on deck that identifies the opening/swing path of the main control room access hatch on the main deck. This will help alleviate the door not being able to close while vehicles onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 29 August 2018
Resolution: Vessel painted a yellow area detailing the swing area of the watertight hatch to the engine control room.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 16 May 2018
Resolved
Install ground detection as per comment #9 listed in MSC return for revision ltr dtd 16Jun17. E2-172071
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2018
Resolved 16 November 2018
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 16 May 2018
Resolved
Replace jacket water hoses on the SSDGs with hoses that meet J1942.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Resolution: Verified vessel installed J1942 approved jacket water hoses on new gensets.
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2018
Resolved
Provide approved plans for the electrical one-line diagram, electrical AC load analysis, and main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 29 August 2018
Resolution: Vessel provided approval for vessel's one-line diagram for the AC load analysis.
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2018
Resolved
Revise AC one line dwg to reflect correct location of the emergency switchboard CB on SS SWBD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 29 August 2018
Resolution: Vessel provided approval letter from MSC for the revisions for the AC one-line drawing.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 16 May 2018
Resolved
Provide plan approval for dwgs/PSTP/DVTP testing the speed interlock.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 3 May 2019
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 16 May 2018
Resolved
Identify and repair communication fault/nuisance alarm on the SSDG alarm panels located on the bridges.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Resolution: Vessel repaired communication fault/nuisance alarm on SSDG.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 16 May 2018
Resolved
Provide updated compass deviation table.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Resolution: Vessel provided a new deviation card for the compass.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 May 2018
Resolved
Conduct man overboard, security, and fire drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 31 May 2018
Resolution: Vessel was able to demonstrate satisfactory man overboard, security, and fire drill.
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2018
Resolved
Remove dead ended cables that were tied into the main switchboard and emergency switchboard for the EDG feedback circuit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2018
Resolved 16 November 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 October 2017
Resolved
Provide U.S. Coast Guard approved Qualitivative Failure Analysis (QFA), Design Verification Test Procedure (DVTP), and Periodic Safety Tests Procedure (PSTP) for newly installed generator switchboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2018
Resolution: msc approved/tested local ref msc e2-1801862 ltr
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 October 2017
Resolved
PFD locker on car deck was decommissioned for installation of new emergency fuel shutoff device. Provide updated Fire & Safety Plan for OCMI review and approval.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 16 November 2018
Stability › Incline Test › General
Issued 27 October 2017
Resolved
Conduct assessment of vessel's stability to show the total aggregate weight change (due to replacement of vessel's SSGs) doesn not exceed 2% of the currently approved lightship displacement and the longitudnal center of gravidty does not shif by more than 1% of the vessel's lenght between perpendiculars. Assessment/calculations are to be provided to the Coast Guard Marine Safety Center for review.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2018
Resolution: New Stability letter issued.
Electrical › Electric Generation Source (service) › Generator
Issued 27 October 2017
Resolved
Provide approved "as built" plans associated with SSGs renewal. Plans to be submitted to Coast Guard Marine Safety Center for review/approval.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 29 August 2018
Resolution: Vessel provided approval letter for new SSDG installations.
Engineering › Bilge Water Management System › Piping
Issued 27 October 2017
Resolved
Conduct pressure test of repaired ballast piping in forward steering gear machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2018
Resolution: pressure tested sat.
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 October 2017
Resolved
Vessel's fuel oil shut off button located on the main car deck is easily accessible to passengers. Provide a different means to shut down the fuel oil.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 12 April 2018
Resolution: The fuel shutoff button located on the car deck is a shut off for the transfer pump, not an emergency shutdown.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 October 2017
Resolved
Vessel is not properly using the company's lock out/tag procedure. Vessel has several pieces of tape over many fuses in panel boards in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 12 April 2018
Resolution: New switchboard installed.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 4 October 2017
Resolved
Vessel has a large amount of oil waste in the bilge. Vessel is to remove the oil water waste to prevent a fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 12 April 2018
Resolution: Bilges pumped/cleaned.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 October 2017
Resolved
Vessel has vast amounts of combustible equipment in the engine room. Vessel is to conduct housekeeping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 12 April 2018
Resolution: Combustibles removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 October 2017
Resolved
Vessels's first aid kit was found to have many expired items. Vessel is to replace the expired items with unexpired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 14 May 2018
Resolution: all renewed dureing 2018 COI
Lifesaving › Hand Flares › Expired
Issued 4 October 2017
Resolved
Vessel's hand flares were found expired. Replace with unexpired ones.
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 5 October 2017
Engineering › Generator (propulsion-electric) › Winding
Issued 2 June 2017
Resolved
Gen winding possible grounded to case and caught fire.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 12 April 2018
Resolution: SSGs renewed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 May 2017
Resolved
Conduct drills: security, man overboard, and fire to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 21 June 2017
Resolution: Conducted satisfactory drills
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 10 May 2017
Resolved
Complete DVTP USGC MSC review, test as required, fwd main engine reversing interlock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 4 June 2018
Resolution: re-wrote 835, reissued plan approval only tested sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 May 2017
Resolved
Label remote fuel transfer pump shutoff outside the house of the #2 motor room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 11 May 2017
Communications › Alarms/Indicators › High Water Alarm
Issued 10 May 2017
Resolved
Repair/replace high jacket water alarm indicator on the local panel for the emgergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 11 May 2017
Engineering › Electric Propulsion System › Interlock Circuitry
Issued 28 April 2017
Resolved
Obtain plan approval from MSC for the DVTPs/PSTPs for the fwd MDE propulsion interlock system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 10 May 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 April 2017
Resolved
Replace steel grating at bottom of ladders in both emergency steering
rooms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 May 2017
Engineering › Bilge Water Management System › Not Operational
Issued 24 April 2017
Resolved
Unable to take bilge suction from both fwd and aft steering room bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 May 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 April 2017
Resolved
Label bilge alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 10 May 2017
Stability › Watertight Integrity › General
Issued 24 April 2017
Resolved
Hydraulic watertight door in the E/R will not function correctly, it is unable to close, open, close using the accumulator tank and will not close remotely from the bridge properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 May 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 September 2016
Resolved
Vessel's class III sliding watertight door located in the engine room spaces does not operate as designed. Door does not close within the time required times. Vessel is to take the door out of service and to permanently leave it in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 September 2016
Resolution: verified vessel's class III watertight door was taken out of service. Crew removed the two main hydraulic lines along with tagging it out.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 September 2016
Resolved
Light covers in overhead IWO CO2 room are missing. Provide light covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 September 2016
Resolved
CO2 discharge for engine room instructions are not clearly understood. Rewrite instructions to clearly understand how to activate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 September 2016
Resolved
Life buoy water light on bridge deck had an expired battery. Provide an unexpired battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 24 April 2017
Operations/Management › Drills/Instruction › Safety Orientation
Issued 9 September 2016
Resolved
Update training manual to reflect correct life rafts onboard vsl.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 September 2016
Resolved
batteries onboard the vessel found for the MDE have wire nuts on them. remove wing nuts and put on correct terminals.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 September 2016
Resolved
numerous lose items found throughout the ER space. Clean up and remove lose items. House keeping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 September 2016
Resolved
Remove 5 gallon can of lube oil from er.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Construction/Loadline › Hull › Weld
Issued 6 July 2016
Resolved
C/R port side Woods Hole end railing. Provide repair proposal prior to C/R. In addition a Coast Guard Marine Inspector must attend vessel for final weld once repairs are completed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 23 January 2017
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 9 June 2016
Resolved
Accumulator bottles are leaking hydraulic oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2017
Operations/Management › Pollution › Retention of Oily Mixture
Issued 9 June 2016
Resolved
Lube oil in engine room, remove L/O
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 September 2016
Resolution: oil has been removed
Engineering › Steering Gear System › Pin
Issued 27 May 2016
Resolved
Make permanent repairs to the tiller arm assembly and collar on the vinyard haven side within 7 days by June 3, 2016 to the satisfaction of a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 May 2016
Resolved
Provide adequate alcohol test kits prior to carrying passengers.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the manual vent closure for the MSD space (port aft L/jacket storage).
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Manual vent closure has been repaired.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the round vent closures for the main deck male and female heads on the main deck.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Vent closure has been rectified.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the main deck men's head vent closure (does not close).
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Vent has been rectified.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the female head ventilation cover dogs.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Vent has been rectified.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 May 2016
Resolved
Label the two motor room emergency escapes on the freight deck
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 9 June 2016
Resolution: cwo v
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 May 2016
Resolved
Update the fire control plan by removing the 50 person IBA.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Plan has been updated to reflect actual IBA count
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 20 May 2016
Resolved
Install a 2nd portable fire extinguisher in the forward and aft steering compartments or update the fire control plan to reflect 1 portable fire extinguisher in each space.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 29 July 2016
Resolution: crm
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Lubricate the supply vent in the aft end of the emergency generator space.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 9 June 2016
Resolution: Supply fans have been lubricated.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 May 2016
Resolved
Conduct underway man overboard, fire, abandon ship and security drills.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: Drills were conducted satisfactorily
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 20 May 2016
Resolved
Sliding watertight door does not close remote. Does not accumulate hydraulic pressure Fr (03) movements. Must be closed at all times while the vessel is underway.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 10 May 2017
Electrical › Electric Generation Source (service) › Power Requirement
Issued 20 May 2016
Resolved
SSDG #1 fails to restart after warming up for 20 minutes.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: cwov
Lifesaving › Launching Appliances › Winch
Issued 20 May 2016
Resolved
Rescue boat not visible to winch operator "on deck" at all times during lowering. Remote umbilical does not include lower button.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 24 April 2017
Resolution: added lowering button to remote umbilical, sat.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 19 May 2016
Resolved
update to include new rescue boat/launching appliance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016
Resolved
obtain approved plans for AC unit install bowling alley, inspect by MI to approved plans.
Due 19 June 2016
Resolved 1 July 2016
Resolution: [name withheld] INSPECTED.
Stability › Incline Test › General
Issued 19 May 2016
Resolved
obtain MSC approval of all wieght changes to date; incld liferaft reconfiguration.
Due 19 June 2016
Resolved 9 August 2016
Resolution: msc ser#H2-1602872
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 19 May 2016
Resolved
label indicators bow and stern each pilot house.
Condition: Improper Installation
Due 19 June 2016
Resolved 9 June 2016
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 19 May 2016
Resolved
create log or checksheet for all lifesaving equip inspections 46 CFR 199.190
Due 19 June 2016
Resolved 29 July 2016
Resolution: log sheet created see act docs
Electrical › Electrical Distribution System (service) › Switch
Issued 19 May 2016
Resolved
replace rescue boat light switch on deck at rescue boat.
Due 1 June 2016
Resolved 20 May 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 19 May 2016
Resolved
replace cable bow liferaft embark light on bowling alley cut sheathing/ cracked wasted.
Due 19 June 2016
Resolved 20 May 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 May 2016
Resolved
repair aft lifraft embark light will not hold posn.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2016
Resolved 20 May 2016
Resolution: repaired.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 May 2016
Resolved
Repair wasted louver/damper for emergency generator space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 16 May 2016
Resolved
Repair main fuel tank high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Lifesaving › Rescue Boat › Carriage Requirement
Issued 16 May 2016
Resolved
Conduct weight test on rescue boat/davit IAW MSM Vol II procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Stability › Incline Test › General
Issued 16 May 2016
Resolved
Provide stability assessment addressing weights added and removed from
passenger cabin (bowling alley) and concrete removed from both stern tube
voids.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 16 May 2016
Resolved
Repair aft shaft tachometer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 16 May 2016
Resolved
Adjust both rudder angle indicators. Both are out > 10 degrees.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 September 2015
Resolved
Crew mess door IWO passenger area is slamming and is a safety and security hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 9 October 2015
Resolution: Door has been adjusted satisfactory.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 22 September 2015
Resolved
Non-combustible trash cans in bowling areas. Remove and install proper trash cans
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 9 October 2015
Resolution: Non-combustible trash cans have been installed throughout the vessel.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 22 September 2015
Resolved
Signage for fire dampers for Martha's Vineyard side is worn. Needs to be updated
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 9 October 2015
Resolution: All signage has been updated.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 September 2015
Resolved
Signage for CO2 cyclinders valve control is wasted. Needs o be updated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 9 October 2015
Resolution: Signage has been updated.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2015
Resolved
Aft end light fixture in way of day tank is broken. replace cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 9 October 2015
Resolution: Light fixture has been replaced.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 September 2015
Resolved
Woods Hole end p/w piping soft patch. repair pipe properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 16 May 2016
Resolution: Piping renewed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 September 2015
Resolved
Woods Hole end and M/V end have large quantities of dirty oil in bilge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 9 October 2015
Resolution: bilges have been cleaned satisfactory.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 22 September 2015
Resolved
R/W pump is leaking on #1SSDG. repair R/W pump PTCP
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2015
Resolved 9 October 2015
Resolution: R/W pump was changed out and the SSDG is up and running as desinged.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 22 September 2015
Resolved
L/O leak on #2SSDG. Repair L/O leak PTCP
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2015
Resolved 20 May 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 September 2015
Resolved
All first aid kits on vessel need to be updated
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 9 October 2015
Resolution: All first aid kits have been updated.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 September 2015
Resolved
ECR light coveres are missing. install light covers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 9 October 2015
Resolution: Light fixture has been replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 August 2015
Resolved
Vessel reported mechanical failure and voluntarily removed vessel from service. Vessel must provide information and corrective actions
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2015
Resolution: Vessel discovered water leaking in from shaft flange bolts. All bolts had backed off and was allowing water to enter. Vessel added lock wire and lock washers to rectify issue.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 August 2015
Resolved
remove oily water from all spaces.: FWD aft peak #2, Engine room, Shaft alley & Void
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2015
Resolution: Vessel removed all oily water from spaces.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 28 August 2015
Resolved
Replace steering gear hatch cover and replace gaskets and chalk test fwd peak hatch, shaft alley hatch, after peak hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2015
Resolution: Vessel rep replaced hatch cover for the steering gear and chalk tested all other hatches. Some hatches needed new gaskets or dogs needed to be tightened.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 28 August 2015
Resolved
Conduct sea trial.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2015
Resolution: Vessel conducted sea trial. No water coming in through the shaft flange bolts at the time of the sea trial.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 28 August 2015
Resolved
Lock wire shaft flange bolts on woods hole end shaft
Action required: 705 - Other - as specified
Resolved 29 August 2015
Resolution: Received pictures form the [name withheld] showing that the flange bolts have been wire locked.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 August 2015
Resolved
remove remaining bilge water in spaces listed: Shaft alley, ballast tanks, voids and engine room.
Action required: 705 - Other - as specified
Resolved 28 August 2015
Resolution: Ship’s [name withheld] provided pictures showing that the bilges were clean and dry.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 28 August 2015
Resolved
Provide plan to rectify ballast piping that is wasted.
Action required: 705 - Other - as specified
Resolved 16 May 2016
Resolution: Piping renewed.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 26 June 2012
Resolved
Complete 1-1/4 hydro test & demonstrate proper operation of boiler automation & safeties prior to commissioning boiler for cold weather season.
Action required: 705 - Other - as specified
Due 10 September 2012
Resolved 24 October 2012
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 29 April 2011
Resolved
Complete remaining DVTP items 7, 8, 9, 10, 14
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 February 2011
Resolved
Re-label C02 system to align with new engineroom configuration
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2011
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 February 2011
Resolved
Repair potable water piping (syntho glass) in sewage hold room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2011
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 February 2011
Resolved
Repair holes in sewage pipe in sewage hold room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Engineering › Generator (propulsion-electric) › Winding
Issued 5 October 2010
Resolved
Identify the cause and properly repair the propulsion motor failure which occurred Oct 1st 2010. Upon proper repairs, demonstrate satisfactory operation to CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2011
Resolution: No definitive cause for the motor failure was identified. The entire propulsion system was converted from diesel electric to diesel reduction.
Engineering › Electric Propulsion System › Winding
Issued 1 October 2010
Resolved
Trouble shoot and identify cause of propulsion failure. Properly repair and demonstrate satisfactory operation.
Action required: 705 - Other - as specified
Resolved 14 January 2011
Resolution: Propulsion plant being converted to conventional diesel reduction.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 May 2009
Resolved
Demonstrate ability to perform satisfactory underway manuvering and man overboard drills to USCG with embarked crewmembers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 28 May 2009
Resolution: Conducted with satisfactory results.
Operations/Management › Drills/Instruction › Fire
Issued 1 May 2009
Resolved
Demonstrate ability to satisfactorily perform an underway fire drill to USCG inspector with embarked crewmembers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 28 May 2009
Resolution: Conducted with satisfactory results.
Engineering › Lubricating Oil Service System › Cooler
Issued 1 May 2009
Resolved
Prior to commercial operations identify source of jacket water leak and repair same that has been located in the #1 generator lube oil cooler to satisfaction of USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 May 2009
Electrical › Electric Generation Source (service) › Power Requirement
Issued 1 May 2009
Resolved
Prior to commercial operations install a new, fully operational #3 main motor SCR power relay circuit breaker to satisfaction of USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 May 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 1 May 2009
Resolved
Prior to commercial operations prove proper operation of the ship's MSD high level alarm indicator to attending USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 16 May 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 May 2009
Resolved
Prior to getting vessel underway properly stow all Lifesaving and Fire Fighting equipment in approved stowage locations to satisfaction of USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 May 2009
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 1 May 2009
Resolved
Prior to commercial operations properly install the ship's EPIRB in its approved location to satisfaction of USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 May 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 May 2009
Resolved
Prior to commercial operations provide a USCG inspector with a current annual servicing report from an approved fixed gas fire extinguishing system servicing company.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 15 May 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 March 2009
Resolved
Replace deck grating in aft stern tube space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2009
Resolution: Verified as completed this date.
Engineering › Bilge Water Management System › Strainer
Issued 23 March 2009
Resolved
Replace bilge strainer in aft stern tube space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2009
Resolution: Verified as completed this date.
Deck/Cargo › Holds/Tanks › Coaming
Issued 23 March 2009
Resolved
Prove proper operation of watertight door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2009
Engineering › Bilge Water Management System › Manifold
Issued 23 March 2009
Resolved
Conduct operational test of bilge system in the presence of a U.S. Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2009
Resolution: Verified as completed this date.
Construction/Loadline › Hull › Bottom Plating
Issued 3 March 2009
Resolved
Vessel overdue for drydock. Vessel taken out of service until drydock completed. Vessel rep [name withheld] office regarding lack of drydock availability. Vessel rep voluntarily took vessel off its run and is not carrying passengers until receiving satisfactory drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Resolution: Credit Hull/ISE completed.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 22 September 2008
Resolved
Engine failed to start and run reliably
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 September 2008
Resolved 22 September 2008
Resolution: Engine was replaced with new.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2008
Resolved
Remove lighting fixture from engine room work bench.
Due 20 June 2008
Resolved 19 June 2008
Resolution: corrected this date
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2008
Resolved
Replace guards to motor in aft motor room.
Due 20 June 2008
Resolved 16 May 2008
Construction/Loadline › Structures › Manhole
Issued 15 May 2008
Resolved
Replace gasket to deck hatches to be watertight.
Due 20 June 2008
Resolved 16 May 2008
Communications › Radio Communications › EPIRB
Issued 5 May 2008
Resolved
Replace EPIRB hydro.
Due 15 May 2008
Resolved 15 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 May 2008
Resolved
Replace time delays for engine room and aft motor room.
Due 15 May 2008
Resolved 15 May 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 May 2008
Resolved
Logbook required entries
Due 15 May 2008
Resolved 15 May 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2008
Resolved
Replenish first aid kit
Due 15 May 2008
Resolved 15 May 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 May 2008
Resolved
Connect corrosion resistant clips to ring buoys.
Due 15 May 2008
Resolved 15 May 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 May 2008
Resolved
Need to provide portable/semiportable extinguishers servicing report.
Due 15 May 2008
Resolved 15 May 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 May 2008
Resolved
Ensure PFDs are stowed according to placards.
Due 15 May 2008
Resolved 15 May 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 5 May 2008
Resolved
Repair MSD vent damper port aft.
Due 15 May 2008
Resolved 15 May 2008
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 5 May 2008
Resolved
Remove all power strips and extension cords not in use.
Due 15 May 2008
Resolved 15 May 2008
Engineering › Steering Gear System › Power Unit
Issued 5 May 2008
Resolved
Test steering/EOT on ship's power.
Due 15 May 2008
Resolved 15 May 2008
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 5 May 2008
Resolved
Operational test of rescue boat and davit during drills.
Due 16 May 2008
Resolved 16 May 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 May 2008
Resolved
Need to complete MOB, fire and security drills.
Due 16 May 2008
Resolved 16 May 2008
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 May 2008
Resolved
Free up aft emg escape hatch to motor room.
Due 15 May 2008
Resolved 15 May 2008
Engineering › Fuel Oil Service System › Piping
Issued 5 May 2008
Resolved
Repair fuel leak to emergency generator.
Due 15 May 2008
Resolved 15 May 2008
Engineering › Bilge Water Management System › Pump
Issued 5 May 2008
Resolved
Test general service pump.
Due 15 May 2008
Resolved 15 May 2008
Construction/Loadline › Structures › Manhole
Issued 5 May 2008
Resolved
Install keeper chains.
Due 20 June 2008
Resolved 16 May 2008
Construction/Loadline › Structures › Manhole
Issued 5 May 2008
Resolved
Replace hatch chain fwd steering compartment.
Due 15 May 2008
Resolved 15 May 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 October 2007
Resolved
Conduct fire and boat drills for a scheduled quarterly exam prior to placing this vessel back in commercial service to satisfaction of an attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 16 May 2008
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 4 May 2007
Resolved
Prior to commercial operations, demonstrate satisfactory operation of all three reverse power relays.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Revrerse power relays operational.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 4 May 2007
Resolved
Prove proper operation of #2 SSDG reverse power relay.
Due 30 May 2007
Resolved 14 May 2007
Resolution: #2 SSDG reverse power relay operational.
Engineering › Compressed Air System (start air) › Valve
Issued 4 May 2007
Resolved
Renew all 4 safety relief valves.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Safety''''s replaced and tested.
Construction/Loadline › Structures › Manhole
Issued 4 May 2007
Resolved
Install keeper chains to hatch openings.
Due 30 May 2007
Resolved 12 June 2007
Resolution: Keepers installed.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 4 May 2007
Resolved
Renew anchor rode double braid shackle.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Anchor rode repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 May 2007
Resolved
Replace inoperable deck lights.
Due 30 May 2007
Resolved 12 June 2007
Resolution: Deck lights replaced.
Engineering › Steering Gear System › Power Unit
Issued 4 May 2007
Resolved
Demonstrate ability to operate steering gear on emergency power.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Steering operated on e-power.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 May 2007
Resolved
Provide updated and ammended DVTPs to local OCMI.
Due 30 May 2007
Resolved 26 June 2007
Resolution: DVTPs provided.
Electrical › Electric Generation Source (service) › Generator
Issued 4 May 2007
Resolved
Demonstrate L/O shutdown function on all SSDGs.
Due 30 May 2007
Resolved 12 June 2007
Resolution: L/O shutdowns tested.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 May 2007
Resolved
Demonstrate e-gen ability to auto start and take load.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Service demonstrated.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 May 2007
Resolved
Demonstrate L/O and overspeed trip for E-gen.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Overspeed trip and L/O shutdown tested.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 4 May 2007
Resolved
Provide servicing report for two semi-portable fire extinguishers in E/R.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Servicing report provided.
Operations/Management › Drills/Instruction › Fire
Issued 4 May 2007
Resolved
Conduct fire drill.
Due 30 June 2007
Resolved 26 June 2007
Resolution: Drills performed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 May 2007
Resolved
Conduct man overboard drill.
Due 30 June 2007
Resolved 26 June 2007
Resolution: Drill performed.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 4 May 2007
Resolved
Prove proper operation of EOT.
Due 30 May 2007
Resolved 14 May 2007
Resolution: EOT operable.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 May 2007
Resolved
Generate and supply an inventory of all non-metallic expansion joints below the water line w/ the installation date and service use.
Due 30 May 2007
Resolved 14 May 2007
Resolution: List provided.
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 March 2007
Resolved
Provide life jacket donning placards
Due 30 May 2007
Resolved 14 May 2007
Resolution: Placards provided.
Lifesaving › Inflatable Liferafts › Servicing
Issued 21 March 2007
Resolved
Provide servicing certs for inflatable liferafts.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Certs provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 March 2007
Resolved
Provide servicing certs for portable fire extinguishers.
Due 30 May 2007
Resolved 14 May 2007
Resolution: Certs provided
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 March 2007
Resolved
Replace time delay to fixed fire extinguisher system in forward motor room.
Due 30 May 2007
Resolved 9 May 2007
Resolution: Time delay replaced and tested.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 March 2007
Resolved
Demonstrate e-lighting works throughout vessel.
Due 30 May 2007
Resolved 12 June 2007
Resolution: E-lights operable.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 5 June 2006
Resolved
Provide ground detection warning system method of operation and proper testing proceudre of same per manufactureer written procedures no later than 30 June 2006.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 12 July 2006
Resolution: Satisfactory Testing Procedures from GE received this date.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 9 May 2006
Resolved
Provide ground detection warning system method of operation and proper testing proceudre of same per manufactureer written procedures no later than 17 May 2006.
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 30 June 2006
Resolution: Extended thru end of June this date
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 May 2006
Resolved
Replace Frequency meter on main switch board and DC voltmeter on #1 end stern motor no later than 17 May 2006.
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 14 June 2006
Resolution: Corrected this date.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 May 2006
Resolved
Replace all missing light covers in engine room no later than 17 May 2006.
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 14 June 2006
Resolution: Corrected this date.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 9 May 2006
Resolved
Obtain and maintain onboard an approved set of design testing and verification procedures no later than 17 May 2006.
Action required: 705 - Other - as specified
Due 2 August 2006
Resolved 26 September 2006
Resolution: Noted corrected onboard the vessel this date.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 9 May 2006
Resolved
Obtain and maintain onboard a set of periodic testing procedures for the Design Testing and Verification procedures which shall specify testing procedures to periodically verify the functionality of the Verification procedures, this to be done no later than 17 May 2006.
Action required: 705 - Other - as specified
Due 2 August 2006
Resolved 26 September 2006
Resolution: Noted corrected onboard the vessel this date.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 May 2006
Resolved
Provide written documentation attesting to the proper servicing of the vessels fire fighting equipment no later than commencement of commercial operations.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 14 June 2006
Resolution: Corrected this date.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 May 2005
Resolved
Install master controls for class III WTD in both pilot houses. Demonstrate operation to attending Coast Guard marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 9 May 2006
Resolution: Witnessed satisfactory operation this date.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 March 2005
Resolved
CG-835 item 01 of 25 MAR 05 is modified as follows: Vessel is allowed to carry passengers provided that sliding watertight door at frame 0 remains closed and tagged out of operation. Proper operation of door to be demonstrated to CG marine inspector prior to 25 APR 05.
Action required: 705 - Other - as specified
Due 25 April 2005
Resolved 4 May 2005
Resolution: Witnessed proper operation of door per ASTM standards.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 25 March 2005
Resolved
COMPLETE MAIN ENGINE TESTING INCLUDING OVERSPEEDS AND REVERSE POWER RELAYS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2005
Resolved 28 March 2005
Resolution: ENGINE TESTING COMPLETED SAT.
Engineering › Compressed Air System (start air) › Compressor
Issued 25 March 2005
Resolved
INSTALL AIR COMPRESSOR RELEIF VALVES BETWEEN COMPRESSORS AND STOP VALVES BEFORE AIR RECEIVER TANKS.
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 9 May 2006
Resolution: Witnessed satisfactory operation this date.
Construction/Loadline › Structures › Plowshare Breakwater
Issued 25 March 2005
Resolved
PROVIDE AS BUILT AND APPROVED PLANS FOR BOW AND STERN MAIN DECK DODGERS.
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 5 June 2006
Resolution: Canceled this date
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 March 2005
Resolved
CONDUCT UNDERWAY DRILLS.
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 19 May 2005
Resolution: DRILLS COMPLETED.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 11 June 2004
Resolved
1. Provide training manual in accordance with 46 CFR 199.180, with emphasis on procedures for launching and recovering rescue boats.
Due 31 October 2004
Resolved 29 March 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 June 2004
Resolved
2. Submit muster list format for OCMI approval in accordance with 46 CFR 199.217
Due 31 October 2004
Resolved 29 March 2005
Operations/Management › Drills/Instruction › Fire
Issued 12 May 2004
Resolved
Conduct underway fire fighting and life boat drills to the satisfaction of the attending Coast Guard marine inspector.
Due 12 June 2004
Resolved 7 June 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 September 2003
Resolved
REPAIR MALFUNCTIONING LIFE RING LIGHT, LOCATED FORWARD OF RESCUE BOAT.
Action required: 705 - Other - as specified
Due 29 September 2003
Resolved 22 September 2003
Resolution: CREW REPLACED SAME.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 22 September 2003
Resolved
REPLACE DISCHARGED PORTABLE FIRE EXTINGUISHER IN PASSENGER COMPARTMENT.
Action required: 705 - Other - as specified
Due 22 September 2003
Resolved 22 September 2003
Resolution: CREW REPLACED WITH SPARE.
Personnel › Manning/Qualifications
Issued 22 September 2003
Resolved
PROVIDE A COPY OF THE SHIP'S LOGS, COMPLETE PAY RECORDS AND REQUESTS FOR EXCHANGE OF TRIP/WATCH FOR ALL PERSONNEL ASSIGNED TO THE VESSEL FOR THE WEEK OF 06-12 SEPT 03. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 20 October 2003
Resolution: LOGS PROVIDED TO MSO PROVIDENCE FOR REVIEW.
Construction/Loadline › Hull › Transverse Frame
Issued 22 September 2003
Resolved
REPAIR WELD ON THE TRANSVERSE FRAME AT THE TOP OF THE E/R LADDER. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 2 September 2004
Resolution: WELD REPAIR COMPLETED DURING PREVIOUS DOCKSIDE AVAILABILITY AND REQUIREMENT NEVER CLEARED. CLEARE REQUIREMENT. WELD REPAIR COMPLETE.
Operations/Management › Drills/Instruction
Issued 5 May 2003
Resolved
CONDUCT UNDERWAY MAN OVERBOARD AND FIRE DRILLS. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 6 June 2003
Resolved 4 June 2003
Resolution: DRILLS COMPLETED SAT.
Communications › Alarms/Indicators
Issued 5 May 2003
Resolved
COMPLETE INSTALLATION AND PROVE PROPER OPERATION OF THE MAIN ENGINE ALARM PANEL. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Action required: 705 - Other - as specified
Due 6 June 2003
Resolved 4 June 2003
Resolution: ALARM PANEL INSTALLED, OLD PANEL TO REMAIN FOR UNDETERMINED TIME.
Unknown
Issued 2 February 2001
Resolved
SUBMIT PLANS FOR NEW MSD SYSTEM TO MSO FOR APPROVAL.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Lifesaving
Issued 2 February 2001
Resolved
PROVE PROPER OPERATION OF REMOTE (MAIN DECK) EMERGENCY VENTILATION SHUTDOWNS (3 TOTAL).
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Electrical
Issued 2 February 2001
Resolved
PROVE PROPER OPERATIONS OF EMERGENCY LIGHTING WHILE ON EMERGENCY CURCUIT.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Lifesaving
Issued 2 February 2001
Resolved
PROVE PROPER OPERATION OF MAIN SPACE GENERATORS' OVERSPEED, HIGH TEMP AND LOW LUBE SHUTDOWNS.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Navigation
Issued 2 February 2001
Resolved
INSTALL DOUBLE NUTS ON STEERING SYSTEM MAIN CONTROL ARM.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Navigation
Issued 2 February 2001
Resolved
SUBMIT PLANS FOR STEERING GEAR MODIFICATIONS TO MSO FOR APPROVAL.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Navigation
Issued 2 February 2001
Resolved
PROVE PROPER OPERATION OF BRIDGE RUDDER REPEATERS AND STEERING SYTEM'S MANUAL INDICATOR TO ELIMINATE 7 DEGREE DISCREPANCY.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Lifesaving
Issued 2 February 2001
Resolved
PROVIDE UNINCUMBERED ACCESS (ADEQUATE SPACE) FOR EMERGENCY PERSONNEL TO DRESS OUT IN OR NEAR THE GEAR LOCKER OR RELOCATE TO ANOTHER LOCATION.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Engineering
Issued 2 February 2001
Resolved
PROVE PR0PER OPERATION OF BRIDGE/ENGINEROOM PROPULSION BELL SYSTEM.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Lifesaving
Issued 2 February 2001
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM "RED" STROBE LIGHT.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Engineering
Issued 2 February 2001
Resolved
PROVE PROPER OPERATION OF REMOTE (BRIDGE) EMERGENCY PROPULSION SHUTDOWN.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Lifesaving
Issued 2 February 2001
Resolved
INSTALL BACKING/LEANING RAIL ON ESCAPE LADDERS TO EMERGENCY SCUTTLES.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Fire Fighting
Issued 2 February 2001
Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP.
Condition: Unknown
Due 15 February 2001
Resolved 14 February 2001
Accommodation/Occupational Safety
Issued 3 March 1998
Resolved
INSTALL HANDLE FOR EMERGENCY ESCAPE HATCH IN NUMBER ONE ENGINE ROOM.
Condition: Unknown
Due 10 March 1998
Resolved 3 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
RENEW HOSE FOR SEMI- PORTABLE CO-2 EXTINGUISHING SYSTEM LOCATED IN THE NUMBER TWO MOTOR ROOM.
Condition: Unknown
Due 10 March 1998
Resolved 3 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
INSTALL A PORTABLE BII CO-2 FIRE EXTINGUISHER IN FRONT OF THE MAIN SWITCH BOARD.
Condition: Unknown
Due 10 March 1998
Resolved 3 March 1998
Electrical
Issued 3 March 1998
Resolved
INSTALL A DRIP SHIELD AND GUARD OVER NEWLY INSTALLED SHORE TIE PANEL BOX.
Condition: Unknown
Due 10 March 1998
Resolved 3 March 1998
Lifesaving
Issued 3 March 1998
Resolved
RELOCATE STAIRWAY ADJACENT TO NEWLY INSTALLED SHORE TIE PANEL BOX.
Condition: Unknown
Due 10 March 1998
Resolved 3 March 1998
Engineering
Issued 10 July 1997
Resolved
PROVE PROPER OPERATION OF NUMBER ONE MDE UPON COMPLETION OF REPAIRS.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Engineering
Issued 10 July 1997
Resolved
PROVE PROPER OPERATION OF NUMBER # 1 MAIN PROPULSION. TWO OF THREE MDE'S REQUIRED TO OPERATE VESSEL.
Condition: Unknown
Due 15 July 1997
Resolved 30 July 1997
Unknown
Issued 8 May 1997
Resolved
PROVE PROPER OPERATION OF PROPULSION GENERATOR CONTROL, IE. PARALLEL 1&3, 1&2, 2&3 GEN'S UNDER LOAD.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Engineering
Issued 5 February 1997
Resolved
VESSEL IS NOT TO OPERATE UNTIL REPAIRS HAVE BEEN EFFECTED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 19 February 1997
Resolved 4 March 1997
Lifesaving
Issued 4 February 1997
Resolved
Service BAs (renew life lines and retro tape)
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Deck/Cargo
Issued 4 February 1997
Resolved
Remove or lock valve handle for OWS overboard.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 4 February 1997
Resolved
Renew retro reflective tape on rejected life preservers or replace them.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Navigation
Issued 4 February 1997
Resolved
Repair EOT bell on NY bridge.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Navigation
Issued 4 February 1997
Resolved
Effect repairs to NY side steering gear. (Cable is chaffing on outboard sheave).
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Engineering
Issued 4 February 1997
Resolved
Renew fuel oil vent flame screen
Condition: Unknown
Due 4 April 1997
Resolved 3 March 1997
Fire Fighting
Issued 4 February 1997
Resolved
Provide servicing certificates for fixed CO2 systems (including EDG room).
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 4 February 1997
Resolved
Provide date of manufacture for flex couplings on #1,#2, MDE
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Engineering
Issued 4 February 1997
Resolved
Prove proper operation of SCR high temperature alarms.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Accommodation/Occupational Safety
Issued 4 February 1997
Resolved
Lock or remove valve handle on sewage overboard valve
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Electrical
Issued 21 October 1996
Resolved
Conduct sea trials to prove proper operation of propulsion plant prior to carrying passengers.
Condition: Unknown
Due 25 October 1996
Resolved 6 December 1996
Engineering
Issued 1 May 1996
Resolved
ISOLATE CAUSE OF #3 SCR FAILURE & MAKE PROPER REPAIRS TO ELECT. PROPULSION SYSTEM. FERRY IS LIMITED TO CARRYING MOVING VANS AND THEIR OCCUPANTS ONLY. NO PASSENGERS TO BE CARRIED UNTIL A PROPOSED SAFETY PLAN IS APPROVED BY [name withheld] SAFETY WILL BE ENSURED SHOULD POWER FAIL AT DOCKING.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Engineering
Issued 26 February 1996
Resolved
PROPERLY REPAIR MAIN ENGINES. VESSEL CAN NOT OPERATE UNTIL THIS CG-835 IS CLEARED BY AN ATTENDING INSPECTOR.
Condition: Unknown
Due 26 March 1996
Resolved 11 March 1996
Engineering
Issued 26 February 1996
Resolved
A COAST GUARD PETTY OFFICER WITH THOROUGH KNOWLEDGE OF ELECTRICAL SYSTEMS SHALL BE IN ATTENDANCE WHENEVER VSL IS OPERATED. PETTY OFFICER SHALL MONITOR ALARM PANEL TO DETERMINE CAUSE SHOULD VESSEL LOSE PROPULSION POWER.
Condition: Unknown
Due 14 March 1996
Resolved 3 April 1996
Engineering
Issued 6 February 1996
Resolved
Prove proper operation of relief valves on all pressure vessels
Condition: Unknown
Due 30 September 1996
Resolved 9 October 1996
Fire Fighting
Issued 6 February 1996
Resolved
Conduct fire and boat drill
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Engineering
Issued 6 February 1996
Resolved
Prove proper operation of high bilge level alarm in the engine room
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Engineering
Issued 6 February 1996
Resolved
Remove or Prove proper operation of OWS discharge alarm meter.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Lifesaving
Issued 6 February 1996
Resolved
Prove proper operation of alarm panel on Manhattan side pilot house
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Accommodation/Occupational Safety
Issued 4 February 1995
Resolved
INSTALL SCHRAEDER VALVE ON DOMESTIC FRESH WATER TANK.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Engineering
Issued 4 February 1995
Resolved
PROVE PROPER OPERATION OF RELIEF VALVE ON # 1, 3, 4, AIR RCVR'S IN ENGINE ROOM.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Fire Fighting
Issued 4 February 1995
Resolved
HAVE CO2 SYSTEM (FIXED) TESTED, IN THE PRESENCE OF ATTENDING MARINE INSPECTOR, BY AUTH. SUC. REP.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Fire Fighting
Issued 4 February 1995
Resolved
REPAIR/REPLACE CO2 DISCHARGE SIREN LOCATED IN #1 MOTOR ROOM.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Construction/Loadline
Issued 4 February 1995
Resolved
REPAIR LEAKS IN CAR DECK SCUTTLES LEADING TO BOTH STEERING ROOM AND G. I. SIDE MOTOR ROOM.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Engineering
Issued 4 February 1995
Resolved
REMOVE PETCOCK DRAINS FROM ALL RACOR FILTERS AND REPLACED WITH SOLID BODY PLUGS OR VALVE FITTED WITH CAPS.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Electrical
Issued 4 February 1995
Resolved
REPLACE MISSING COVERS ON STOP BOTTON/RUNS LTS ON BILGE PUMP CONTROLLER.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Electrical
Issued 4 February 1995
Resolved
LABEL ALL SPARE CIRCUIT BREAKERS THROUGHOUT MACH. SPACES.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Engineering
Issued 4 February 1995
Resolved
PROVE PROPER OPERATION OF DISCHARGE ALARM/METER ON OW 3.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Navigation
Issued 4 February 1995
Resolved
REPLACE COMPASS IN MANHATTAN PILOT HOUSE.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Navigation
Issued 4 February 1995
Resolved
PROVE PROPER OPERATION OF ALARM PANEL, MANHATTAN PILOT HOUSE.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Accommodation/Occupational Safety
Issued 4 February 1995
Resolved
REMOVE ALL SOOT ACCUMULATION FROM EXHAUST UPTAKE SPACE (OVERHEAD E-BATTERY SPACE.)
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Navigation
Issued 4 February 1995
Resolved
REPLACE FWD MAST HEAD LIGHT + PROVE OPERATION.
Condition: Unknown
Due 4 February 1995
Resolved 4 February 1995
Navigation
Issued 4 February 1995
Resolved
PROVE PROPER OPERATION OF #1 STEERING PUMP INALL MODELS.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Electrical
Issued 24 February 1994
Resolved
PROVE PROPER OPERATION OF THE EMER GEN H20 DEVICE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Fire Fighting
Issued 24 February 1994
Resolved
STENCIL ALL FIRE HOSES WITH THE VESSEL NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Accommodation/Occupational Safety
Issued 24 February 1994
Resolved
REPAIR VENTS TO MOTOR ROOM ON BOTH ENDS AT THE VEHICLE DECK LEVEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Engineering
Issued 24 February 1994
Resolved
SECURE BRACKETS TO G.I. END STERN TUBE VENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 7 January 1994
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR USING INSTALLED FUEL PIPING/SYSTEM TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR. UNTIL THIS ITEM IS CLEARED VESSEL IS NOT TO BE USED AS THE PRIMARY FERRY BUT CAN BE KEPT IN STANDBY.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Construction/Loadline
Issued 2 August 1993
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR BILGE ALARM.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 10 April 1993
Resolved
CONDUCT AN OPERATIONAL TEST OF THE RESCUE BOAT IN THE PRESENCE OF AN ATTENDING USCG INSPECTOR BY 17 APRIL 1993.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Lifesaving
Issued 25 February 1993
Resolved
CONDUCT AN OPERATIONAL TEST OF THE RESCUE BOAT IN THE PRESENCE OF AN ATTENDING USCG INSPECTOR BY 9 APRIL 1993.
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Unknown
Issued 24 February 1993
Resolved
PROVIDE [name withheld] OF ALL DIVERS REPORTS OR UNDERWATER SURVEYS CONDUCTED ON VESSEL PRIOR TO NEXT CREDIT DRYDOCKING PERIOD.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Electrical
Issued 25 November 1992
Resolved
REPAIR AND PROVE PROPER OPERATION OF #1 SHIPS SERVICE GENERATOR. THIS IS TOBE COMPLETED TO THE SATISFACTION OF ATTENDING U.S.C.G. MARINE INSPECTOR. _x001C_
Condition: Unknown
Due 25 November 1992
Resolved 25 November 1992
Engineering
Issued 4 August 1992
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE #1 SCR TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Engineering
Issued 26 February 1992
Resolved
RELOCATE "T" HANDLES TO PROXIMITY OF FUEL SHUT OFF VALVES.
Condition: Unknown
Due 26 March 1992
Resolved 23 April 1992
Engineering
Issued 26 February 1992
Resolved
PREPARE ALL FOUR 250 PSI (MAWP) AIR RECEIVERS FOR HYDROSTATIC TEST OR VISUAL EXAMINATION BY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 March 1992
Resolved 23 April 1992
Engineering
Issued 26 February 1992
Resolved
APPROPRIATELY LABEL THE FOLLOWING ITEMS: A) ALL PFD STOWAGE AREAS WITH NUMBERS AND TYPE OF PFD. B) ALL FIRE STATIONS (HOSE) WITH STATION NUMBER, C) FUEL OIL VENTS.
Condition: Unknown
Due 28 March 1992
Resolved 23 April 1992
Construction/Loadline
Issued 26 February 1992
Resolved
DETERMINE THAT CORRECT AMOUNT OF LEAD BALLAST AS CALLED FOR IN G-MMT LETTERDATED 16JUL85 SER#50526 IS ONBOARD. REPLACE ANY MISSING BALLAST AS PER DWG#242-WFRY-191-1, BALLAST REPLACEMENT PLAN, 26NOV89.
Condition: Unknown
Due 9 March 1992
Resolved 23 April 1992
Engineering
Issued 26 February 1992
Resolved
REPAIR OIL LEAK IN #3 MAIN PROPULSION GENERATOR TURBOCHARGER.
Condition: Unknown
Due 9 March 1992
Resolved 23 April 1992
Engineering
Issued 26 February 1992
Resolved
REPLACE FUEL OIL VENT SCREENS ON VENT ON PORTSIDE GI END BILGE PUMP DISCHARGE. REPLACE SCREEN ON VENT BY EXIT ON NY SIDE OF PASSENGER SPACE.
Condition: Unknown
Due 26 March 1992
Resolved 23 April 1992
Navigation
Issued 18 April 1991
Resolved
PROVE PROPER OPERATION OF LOSS OF SCR POWER ALARMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 September 1991
Resolved 3 September 1991
Construction/Loadline
Issued 21 December 1990
Resolved
PROVIDE REPORT ON VESSELS SACRIFICIAL ZINC ANODES. REPORT IS TO BE BASED UPON VISUAL EXAMINATION AND IS TO INCLUDE APPROXIMATE PERCENTAGE OF WASTAGEFOR ZINCS IN ALL LOCATIONS. PROVIDE REPORT TO [name withheld].
Condition: Unknown
Due 21 December 1990
Resolved 21 December 1990
Construction/Loadline
Issued 21 December 1990
Resolved
PROVIDE CONDITION REPORT TO [name withheld] ON VESSELS SACRIFICIAL ZINC ANODES. REPORT IS TO BE BASED UPON VISUAL EXAMINATION, AND IS TO INCLUDE APPROXIMATE PERCENTAGE OF WASTAGE FOR ZINCS IN ALL LOCATIONS.
Condition: Unknown
Due 21 December 1990
Resolved 21 December 1990
Construction/Loadline
Issued 21 December 1990
Resolved
PROVIDE CONDITION REPORT IN VESSEL'S SACRIFICIAL ZINC ANODES. REPORT IS TIBE BASED UPON VISUAL EXAMINATION, AND IS TOO INCLUDE APPROXIMATE PERCENTAGEOF WASTAGE FOR ZINCS IN ALL LOCATIONS. PROVIDE REPORT TO [name withheld].
Condition: Unknown
Due 21 December 1990
Resolved 21 December 1990
Construction/Loadline
Issued 21 December 1990
Resolved
PROVIDE CONDITION REPORT ON VESSELS SACRIFICIAL ZINC ANODES. REPORT IS TO BE BASED UPON VISUAL EXAMINATION, AND IS TO INCLUDE APPROXIMATE PERCENTAGE OF WASTAGE FOR ZINCS IN ALL LOCATIONS. PROVIDE REPORT TO [name withheld].
Condition: Unknown
Due 21 December 1990
Resolved 21 December 1990
Engineering
Issued 4 January 1990
Resolved
PROVE THE PROPER OPERATION OF #3 MDE & OF OVERSPEED, LOW OIL PRESSURE SHUT-DOWN, HIGH WATER TEMPERATURE SHUTDOWN AND ALARMS. THIS REQUIREMENT IS CONTINGENT UPON THE SUCESSFUL CORRECTION OF THE MALFUNCTIONING ELECTRONIC CIRCUIT BOARD. THE #3 MDE SHALL NO BE OPERATED UNTIL COMPLETED.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Engineering
Issued 8 November 1989
Resolved
PROVE PROPER OPERATION OF #3 MDE AND OF OVERSPEED, LOW OIL PRESS SHUTDOWN, HIGH WATER TEMP SHUTDOWN AND ALARMS.
Condition: Unknown
Due 8 November 1989
Resolved 8 November 1989
Engineering
Issued 8 November 1989
Resolved
PROVE PROPER OPERATION OF RELIEF VALVES FOR ALL (4) AIR RECEIVERS NOT TO EXCEED 250 PSI.
Condition: Unknown
Due 8 November 1989
Resolved 8 November 1989
Navigation
Issued 8 November 1989
Resolved
PROVIDE INSTRUCTIONS FOR EMERGENCY LOCAL STEERING STATION GOV. IS. END.
Condition: Unknown
Due 8 November 1989
Resolved 8 November 1989
Lifesaving
Issued 17 November 1988
Resolved
PROPERLY REPLACE GRAB LINES ON THREE OF FOUR LIFERINGS ABOARD VESSEL AS NOTED.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Lifesaving
Issued 17 November 1988
Resolved
PROPERLY SERVICE ALL THREE OVERDUE LIFERAFTS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Lifesaving
Issued 17 November 1988
Resolved
PROPERLY SERVICE ALL THREE HYDRAULIC RELEASE UNITS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 17 November 1988
Resolved
PROPERLY RE-ALIGN VESSEL'S RUDDER ORDER INDICATOR WITH ITS RUDDER ANGLE INDICATOR LOCATED AT GOVERNOR'S ISLAND WHEELHOUSE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 17 November 1988
Resolved
ADD FLUID TO MAGNETIC COMPASS LOCATED AT MANHATTAN SIDE WHEELHOUSE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Construction/Loadline
Issued 17 November 1988
Resolved
PROPERLY REPAIR VENTILATION LOUVERS CONNECTED TO MOTOR ROOM #1.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988
Resolved
PROPERLY REPAIR ELECTRIC HORN LOCATED AT MANHATTAN SIDE WHEELHOUSE.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Construction/Loadline
Issued 20 June 1988
Resolved
CROP AND RENEW TO GOOD METAL THE FOLLOWING SPANS OR FRAMES WHERE FRACTURED OR TRIPPED: PORT SIDE FRAMES 25, 20, 15, 10, 5; FORWARD FRAMES 15, 20, 25 AND 31.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Documentation
Issued 3 December 1987
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Lifesaving
Issued 3 December 1987
Resolved
CONDUCT FIRE AND BOAT DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Navigation
Issued 29 September 1986
Resolved
PROVIDE A MARKING SYSTEM FOR ENGINEROOM ENGINE ORDER TELEGRAPH AND MOTOR CONTROLLER TO AVOID CONFUSION WHEN ANSWERING BELLS.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Lifesaving
Issued 29 September 1986
Resolved
PROVIDE 4 ADDITIONAL ADULT LIFEJACKETS AND 2 CHILDRENS LIFEJACKETS. UNTIL THIS IS COMPLETED, VESSEL MAY NOT OPERATE WITH MORE THAN 488 PERSONS ON BOARD.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Navigation
Issued 29 September 1986
Resolved
PROVE PROPER OPERATION OF G.I. END ENGINE ORDER TELEGRAPH ALARM BELL IN ENGINE ROOM.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Navigation
Issued 29 September 1986
Resolved
PROVE PROPER OPERATION OF N.Y. END LOSS OF POWER TO STEERING ALARM.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Engineering
Issued 29 September 1986
Resolved
PROVE PROPER OPERATION OF #1 AND #2 GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Construction/Loadline
Issued 1 October 1985
Resolved
CROP AND RENEW DISTORTED AND FRACTURED AND ADRIFT SPONSON FRAMES #1 - 6 AFT OF FOREMAST, PORT SIDE NO LATER THAN THE VESSELS NEXT CREDIT DRYDOCKINGING APRIL 1986. PRIOR TO PERMANENT REPAIRS, NO VEHICLES SHALL BE PARKED ON THE ADJACENT SPONSON DECK OVERHANG, (APPX. 40'), ON THE PORTSIDE.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Lifesaving
Issued 17 May 1985
Resolved
CONDUCT SATISFACTORY FIRE AND BOAT DRILLS PRIOR TO REGULARLY SCHEDULED OPERATIONS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985