Inspection history · 62
9 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8345352
13 March 2026
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8324570
14 October 2025
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8251603
12 June 2025
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8157743
25 February 2025
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8078837
16 December 2024
In-Service Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8057034
28 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8010853
11 September 2024
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8000065
4 April 2024
Examination of Repairs · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7881948
7 November 2023
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7821498
11 September 2023
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7789575
24 May 2023
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7713226
24 March 2023
Administrative Inspection · Deficiency Check · COI Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7651793
10 August 2022
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7531451
27 July 2022
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7517939
17 May 2022
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7452884
17 May 2022
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7875754
7 April 2022
Examination of Repairs · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7422798
1 February 2022
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7388852
8 September 2021
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7309478
25 August 2021
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7296608
21 May 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7202718
13 May 2021
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7183809
9 March 2021
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7152026
10 October 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7077176
17 June 2020
Examination of Repairs · COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6978286
14 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855826
22 October 2019
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6840878
24 September 2019
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6830362
24 September 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6831628
24 September 2019
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6862380
17 September 2019
DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6810970
13 August 2019
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6782043
19 July 2019
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6794789
28 May 2019
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6702573
28 May 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6727439
3 May 2019
Examination of Repairs · DAPI Audit · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6677800
15 November 2018
Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6582010
28 August 2018
MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6521643
8 July 2018
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6473069
12 June 2018
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6442169
31 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6423326
24 April 2018
MTSA Verification · Examination of Repairs · COI Inspection · DAPI Audit · Deadweight Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6399350
27 October 2017
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6298493
4 October 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6277754
27 September 2017
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6295013
13 July 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6207689
21 June 2017
In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6177730
2 June 2017
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6163842
2 June 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6200069
24 April 2017
DAPI Audit · Examination of Repairs · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6132384
31 January 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6080363
24 January 2017
Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6079522
16 September 2016
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6004033
9 September 2016
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5999438
9 September 2016
Plan Review (Other than "T")
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6006047
6 July 2016
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5931975
6 July 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5940514
9 June 2016
Deficiency Check · MTSA Verification · DAPI Audit · Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5922651
27 May 2016
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5888696
27 May 2016
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5934234
28 April 2016
MTSA Verification · COI Inspection · DAPI Audit · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5864986
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 March 2026
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Vessel did not complete a MOB and Fire Drill during their COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2026
Resolved 9 April 2026
Resolution: Vessel is being sold. Vessel is off the run
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2025
Resolved
Spaces which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on board while the vessel is being navigated shall be fitted with an approved audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. Alarm was broken, prove proper operation of CO2 siren behind the ladder in the vidmar space prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2025
Resolved 10 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2025
Resolved
All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance
with NFPA 10. Provide fire fighting servicing certificates prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2025
Resolved 10 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 25 February 2025
Resolved
Information required for the fire control plan shall be kept up-to-date, any alteration being recorded in the applicable medium as soon as practicable. Update fire control plan and submit to local OCMI for review and approval prior to 06Apr25.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2025
Resolved 21 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2024
Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter. Vessel reported that the #2 Generator has a jacket water leak. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2024
Resolved 4 October 2024
Resolution: See Activity Number 8010853.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 September 2024
Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that—
(a) Illustrate the purpose of controls;
(b) Illustrate the procedures for operating the launching device;
(c) Give relevant instructions or warnings;
The vessel's life raft launching procedures that are posted do not match or work as instructed with the installed raft mount. Correct posted instructions to provide clear direction.
46CFR 199.90
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2024
Resolved 3 October 2024
Resolution: renewed postings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2024
Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. The lifebuoy, mid-deck has clear opening in shell exposing core foam. Provided buoy that is secure from water penetration.
46CFR 199.70.a.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 3 October 2024
Resolution: renewed ring.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 September 2024
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire; ...The lower fire vent closure, as identified has a hole in the closure. Provide a closure that meets the
structural requirements of the installed bulkhead.
46CFR 72.05-50
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 25 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 September 2024
Resolved
All bulkheads and decks shall be classed as A-60, A-30, A-15, A-0, B-15, B-0, or C, depending upon the type of space on each side of the bulkhead or above and below the deck. The engine control room is missing various cutouts of the once installed fire insulation. Vessel to provide boundary IAW the bulkhead tables contained in 46 CFR 72.05-12 to the satisfaction of the attending USCG MI.
46CFR 72.05-50
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 25 February 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 September 2023
Resolved
An MMC, license, MMD, COR, or STCW endorsement must be retained by the mariner to whom it was issued and, while valid, must be produced to verify qualifications when requested by an authorized official as identified in 33 CFR 101.515(d). Posting of the officer endorsement may be necessary as required in 46 U.S.C. 7110. The vessel Chief Engineer was unable to produce an MMC. Vessel was able to locate a properly credentialed Chief Engineer to take over operations over crew change-out.
46 CFR 10.203(b)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 11 September 2023
Resolved 11 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 March 2023
Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation. Vessel is outfitted with fixed concrete ballast at either end of the vessel, that is not accounted for on the stability letter. This additional fixed ballast invalidates the stability letter. Prior to returning to service, submit locations, weights and dates that the concrete was installed to the Marine Safety Center and this office.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2023
Resolved 11 May 2023
Resolution: Vessel received updated stability letter from MSC.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2023
Resolved
In a passenger vessel no oil level gauge sight glasses may require penetration below the top of the tank, and neither the failure of a gauge nor an overfilling of the tank may permit release of fuel into the space. Remove/replace fuel oil day tank sight glass in forward storage room with an approved gauging system.
Action required: 705 - Other - as specified
Due 17 June 2023
Resolved 4 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 24 March 2023
Resolved
Submit corrected fire control plan to the local OCMI for review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 10 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2022
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs, or a defect is discovered with affects the safety of the vessel. Vessels bow engine experienced loss of propulsion on approach to company dock in Woods Hole Massachusetts. Effect repairs as necessary and demonstrate satisfactory operation to the satisfaction of the attending Marine Inspector. 46CFR71.40-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022
Resolved 19 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2021
Resolved
A survey, either general or partial shall be made every time a defect is discovered which affects the safety of the vessel. Vessel reported the forward engine shut down due to low oil pressure during approach to dock. Prior to carrying passengers, Determine the cause of engine shut down, repair, and conduct a sea trial to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2021
Resolved 25 August 2021
Resolution: See Activity Number 7296608
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2021
Resolved
Repair closure device on the door between passenger and crew accomodation area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 7 June 2021
Resolution: Confirmed new closure has been installed on door between passenger and crew accommmodation area that is fully functional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2021
Resolved
Provide boiler servicing report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 17 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 May 2021
Resolved
Mark emergency escape hatches for the machinery spaces and direction to turn to open.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 7 June 2021
Resolution: Confirmed appropriate signage for emergency escape has been appropriately installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2021
Resolved
Make corrections to June 2020 PSTPs, re-test and verify all test procedures are correct. Submit corrected PSTPs to local OCMI after procedures are verified.
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 13 May 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 May 2021
Resolved
Submit weight change calculations to Marine Safety Center for approval for new mast installations for current stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 21 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 13 May 2021
Resolved
Renew grating btm of ladder of the aft steering machinery room, grating is rotted out and poses a danger to personnel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019
Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
Make permanent repairs to steering system and test to the satisfaction of the attending USCG Marine Inspector prior to carrage of passengers/cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2019
Resolved 24 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
Tube transmission cooler failure. Repair / replace cooler.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2019
Resolved 25 November 2019
Resolution: Repair made to cooler tube bundle, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2019
Resolved
Wirenuts on batteries, Woods Hole end (Motor room 2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 3 October 2019
Resolution: Vessel Installed proper nuts on the batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2019
Resolved
MDE has saltwater leak on the after end onf the engine. Investigate leak. Motor room 1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 8 October 2019
Resolution: Vessel engineer rectified issue.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 September 2019
Resolved
gasket on EDG room is wasted. replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Gasket has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2019
Resolved
Investigate heavy dust particles located on MDE turbo in motor room 2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel crew determined the dust was from in the intake exhaust system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2019
Resolved
#1 MDE derating on alarm codes. Repair and prove proper operation of #1 MDE prior to carriage of passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 May 2019
Resolved
Revise and correct fire control plan as discussed with [name withheld] revised plan to local OCMI for review. Obtain local plan approval prior to 22Jun19.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2019
Resolved 1 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 May 2019
Resolved
Obtain MSC plan approval for MSCORP dwg No. 3233-84-14 "180V/120V electrical mods incidental generator replacement" and IEM Marine Job No. 180-104677 "Main Switchboard" prior to 30Jun2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 17 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2019
Resolved
Submit revised MSCorp dwg No. 3233-84-14 "480V/120V electrical mods incidental generator replacement" and IEM Marine Job No. 180-104677 "Main Switchboard" for MSC approval as noted in MSC ltr E2-1801766 dtd 14May2018 to address comments #4 and #9 and comment #4 on MSC ltr E2-1802082 dtd 13Jun2018.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
Resolution: Dwgs Submitted to MSC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2019
Resolved
Master PSTPs do not reflect testing actually performed on the vessel. Modify PSTPs and submit to local OCMI for approval, verification, and testing prior to next issuance of COI in 2020.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 May 2021
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 3 May 2019
Resolved
Indicator lights not functioning. Repair indicator lights on the water tight doors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2019
Resolved
120 VAC Dist panel indicates a ground on Island Space Heating PL #2. Repair ground.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
Emergency lighting for rescue boat is inoperable. Repair emergency lighting for the rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019
Resolved
Emergency lights exterior of house on vehicle deck are not on the emgerency circuit. Repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2019
Resolution: Not required per Regulations and not installed IAW orginial electrical dwgs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 November 2018
Resolved
Revise A/C one line dwg, A/C load analysis, and Fault Current Analysis and Protective Device Coordination study to reflect as built and obtain plan approval from MSC.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 November 2018
Resolved
Crop and renew wasted through decking in crew cleaning locker on main deck to good metal or provide a written repair proposal to the OCMI for review and determination.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 26 November 2018
Resolved
Make vessel available for inspection for USCG verification and approval of Fire and Safety plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Provide Marine Safety Center (MSC) approved plans for references (d) and (g) noted in MSC ltr E2-1801766 dtd May 14, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Cleared and re-issued to submit revised plans to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Address comments # 2, 4, 5, and 9 in MSC ltr E2-1801766 dtd May 14, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Cleared and re-issued to submit revised plans to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Address comments #3 and #4 noted in MSC ltr E2-1802082 dtd June 13, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Resolution: Cleared and re-issued to submit revised plans to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
Provide copy of latest approved plans noted in reference (a) and (b) in MSC ltr E2-1802082 dtd June 13, 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2018
Resolved
Cannon plug wires parted on the Woods Hole end transmission.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 July 2018
Resolved 29 August 2018
Resolution: Vessel repaired cannon plugs on the Woods Hole End transmission.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2018
Resolved
Throttle positioning sensor is actively going off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 July 2018
Resolved 29 August 2018
Resolution: Vessel repaired throttle positioning sensor.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 12 June 2018
Resolved
Fuel oil pressure alarm active on main diesel engine, repair / replace, prove propper operation of fuel system on main engine, prior to operations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 29 August 2018
Resolution: Vessel repaired fuel oil pressure alarm on main diesel engine.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 31 May 2018
Resolved
Mark area on deck that identifies the opening/swing path of the main control room access hatch on the main deck. This will help alleviate the door not being able to close while vehicles onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 29 August 2018
Resolution: Vessel painted a yellow area detailing the swing area of the watertight hatch to the engine control room.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 16 May 2018
Resolved
Install ground detection as per comment #9 listed in MSC return for revision ltr dtd 16Jun17. E2-172071
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2018
Resolved 16 November 2018
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 16 May 2018
Resolved
Replace jacket water hoses on the SSDGs with hoses that meet J1942.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Resolution: Verified vessel installed J1942 approved jacket water hoses on new gensets.
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2018
Resolved
Provide approved plans for the electrical one-line diagram, electrical AC load analysis, and main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 29 August 2018
Resolution: Vessel provided approval for vessel's one-line diagram for the AC load analysis.
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2018
Resolved
Revise AC one line dwg to reflect correct location of the emergency switchboard CB on SS SWBD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 29 August 2018
Resolution: Vessel provided approval letter from MSC for the revisions for the AC one-line drawing.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 16 May 2018
Resolved
Provide plan approval for dwgs/PSTP/DVTP testing the speed interlock.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 3 May 2019
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 16 May 2018
Resolved
Identify and repair communication fault/nuisance alarm on the SSDG alarm panels located on the bridges.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Resolution: Vessel repaired communication fault/nuisance alarm on SSDG.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 16 May 2018
Resolved
Provide updated compass deviation table.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2018
Resolved 31 May 2018
Resolution: Vessel provided a new deviation card for the compass.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 May 2018
Resolved
Conduct man overboard, security, and fire drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 31 May 2018
Resolution: Vessel was able to demonstrate satisfactory man overboard, security, and fire drill.
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2018
Resolved
Remove dead ended cables that were tied into the main switchboard and emergency switchboard for the EDG feedback circuit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2018
Resolved 16 November 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 October 2017
Resolved
Provide U.S. Coast Guard approved Qualitivative Failure Analysis (QFA), Design Verification Test Procedure (DVTP), and Periodic Safety Tests Procedure (PSTP) for newly installed generator switchboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2018
Resolution: msc approved/tested local ref msc e2-1801862 ltr
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 October 2017
Resolved
PFD locker on car deck was decommissioned for installation of new emergency fuel shutoff device. Provide updated Fire & Safety Plan for OCMI review and approval.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 16 November 2018
Stability › Incline Test › General
Issued 27 October 2017
Resolved
Conduct assessment of vessel's stability to show the total aggregate weight change (due to replacement of vessel's SSGs) doesn not exceed 2% of the currently approved lightship displacement and the longitudnal center of gravidty does not shif by more than 1% of the vessel's lenght between perpendiculars. Assessment/calculations are to be provided to the Coast Guard Marine Safety Center for review.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2018
Resolution: New Stability letter issued.
Electrical › Electric Generation Source (service) › Generator
Issued 27 October 2017
Resolved
Provide approved "as built" plans associated with SSGs renewal. Plans to be submitted to Coast Guard Marine Safety Center for review/approval.
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 29 August 2018
Resolution: Vessel provided approval letter for new SSDG installations.
Engineering › Bilge Water Management System › Piping
Issued 27 October 2017
Resolved
Conduct pressure test of repaired ballast piping in forward steering gear machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2018
Resolution: pressure tested sat.
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 October 2017
Resolved
Vessel's fuel oil shut off button located on the main car deck is easily accessible to passengers. Provide a different means to shut down the fuel oil.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 12 April 2018
Resolution: The fuel shutoff button located on the car deck is a shut off for the transfer pump, not an emergency shutdown.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 October 2017
Resolved
Vessel is not properly using the company's lock out/tag procedure. Vessel has several pieces of tape over many fuses in panel boards in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 12 April 2018
Resolution: New switchboard installed.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 4 October 2017
Resolved
Vessel has a large amount of oil waste in the bilge. Vessel is to remove the oil water waste to prevent a fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2017
Resolved 12 April 2018
Resolution: Bilges pumped/cleaned.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 October 2017
Resolved
Vessel has vast amounts of combustible equipment in the engine room. Vessel is to conduct housekeeping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 12 April 2018
Resolution: Combustibles removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 October 2017
Resolved
Vessels's first aid kit was found to have many expired items. Vessel is to replace the expired items with unexpired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 14 May 2018
Resolution: all renewed dureing 2018 COI
Lifesaving › Hand Flares › Expired
Issued 4 October 2017
Resolved
Vessel's hand flares were found expired. Replace with unexpired ones.
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 5 October 2017
Engineering › Generator (propulsion-electric) › Winding
Issued 2 June 2017
Resolved
Gen winding possible grounded to case and caught fire.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 12 April 2018
Resolution: SSGs renewed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 May 2017
Resolved
Conduct drills: security, man overboard, and fire to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 21 June 2017
Resolution: Conducted satisfactory drills
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 10 May 2017
Resolved
Complete DVTP USGC MSC review, test as required, fwd main engine reversing interlock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 4 June 2018
Resolution: re-wrote 835, reissued plan approval only tested sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 May 2017
Resolved
Label remote fuel transfer pump shutoff outside the house of the #2 motor room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 11 May 2017
Communications › Alarms/Indicators › High Water Alarm
Issued 10 May 2017
Resolved
Repair/replace high jacket water alarm indicator on the local panel for the emgergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 11 May 2017
Engineering › Electric Propulsion System › Interlock Circuitry
Issued 28 April 2017
Resolved
Obtain plan approval from MSC for the DVTPs/PSTPs for the fwd MDE propulsion interlock system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 10 May 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 April 2017
Resolved
Replace steel grating at bottom of ladders in both emergency steering
rooms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 May 2017
Engineering › Bilge Water Management System › Not Operational
Issued 24 April 2017
Resolved
Unable to take bilge suction from both fwd and aft steering room bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 May 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 April 2017
Resolved
Label bilge alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 10 May 2017
Stability › Watertight Integrity › General
Issued 24 April 2017
Resolved
Hydraulic watertight door in the E/R will not function correctly, it is unable to close, open, close using the accumulator tank and will not close remotely from the bridge properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 May 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 September 2016
Resolved
Vessel's class III sliding watertight door located in the engine room spaces does not operate as designed. Door does not close within the time required times. Vessel is to take the door out of service and to permanently leave it in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 September 2016
Resolution: verified vessel's class III watertight door was taken out of service. Crew removed the two main hydraulic lines along with tagging it out.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 September 2016
Resolved
Light covers in overhead IWO CO2 room are missing. Provide light covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 September 2016
Resolved
CO2 discharge for engine room instructions are not clearly understood. Rewrite instructions to clearly understand how to activate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 September 2016
Resolved
Life buoy water light on bridge deck had an expired battery. Provide an unexpired battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 24 April 2017
Operations/Management › Drills/Instruction › Safety Orientation
Issued 9 September 2016
Resolved
Update training manual to reflect correct life rafts onboard vsl.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 September 2016
Resolved
batteries onboard the vessel found for the MDE have wire nuts on them. remove wing nuts and put on correct terminals.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 September 2016
Resolved
numerous lose items found throughout the ER space. Clean up and remove lose items. House keeping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 September 2016
Resolved
Remove 5 gallon can of lube oil from er.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 10 May 2017
Construction/Loadline › Hull › Weld
Issued 6 July 2016
Resolved
C/R port side Woods Hole end railing. Provide repair proposal prior to C/R. In addition a Coast Guard Marine Inspector must attend vessel for final weld once repairs are completed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 23 January 2017
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 9 June 2016
Resolved
Accumulator bottles are leaking hydraulic oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2017
Operations/Management › Pollution › Retention of Oily Mixture
Issued 9 June 2016
Resolved
Lube oil in engine room, remove L/O
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 September 2016
Resolution: oil has been removed
Engineering › Steering Gear System › Pin
Issued 27 May 2016
Resolved
Make permanent repairs to the tiller arm assembly and collar on the vinyard haven side within 7 days by June 3, 2016 to the satisfaction of a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 May 2016
Resolved
Provide adequate alcohol test kits prior to carrying passengers.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the manual vent closure for the MSD space (port aft L/jacket storage).
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Manual vent closure has been repaired.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the round vent closures for the main deck male and female heads on the main deck.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Vent closure has been rectified.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the main deck men's head vent closure (does not close).
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Vent has been rectified.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Properly repair the female head ventilation cover dogs.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Vent has been rectified.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 May 2016
Resolved
Label the two motor room emergency escapes on the freight deck
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 9 June 2016
Resolution: cwo v
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 May 2016
Resolved
Update the fire control plan by removing the 50 person IBA.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Resolution: Plan has been updated to reflect actual IBA count
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 20 May 2016
Resolved
Install a 2nd portable fire extinguisher in the forward and aft steering compartments or update the fire control plan to reflect 1 portable fire extinguisher in each space.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 29 July 2016
Resolution: crm
Accommodation/Occupational Safety › Ventilation › General
Issued 20 May 2016
Resolved
Lubricate the supply vent in the aft end of the emergency generator space.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 9 June 2016
Resolution: Supply fans have been lubricated.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 May 2016
Resolved
Conduct underway man overboard, fire, abandon ship and security drills.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: Drills were conducted satisfactorily
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 20 May 2016
Resolved
Sliding watertight door does not close remote. Does not accumulate hydraulic pressure Fr (03) movements. Must be closed at all times while the vessel is underway.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 10 May 2017
Electrical › Electric Generation Source (service) › Power Requirement
Issued 20 May 2016
Resolved
SSDG #1 fails to restart after warming up for 20 minutes.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: cwov
Lifesaving › Launching Appliances › Winch
Issued 20 May 2016
Resolved
Rescue boat not visible to winch operator "on deck" at all times during lowering. Remote umbilical does not include lower button.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 24 April 2017
Resolution: added lowering button to remote umbilical, sat.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 19 May 2016
Resolved
update to include new rescue boat/launching appliance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 9 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016
Resolved
obtain approved plans for AC unit install bowling alley, inspect by MI to approved plans.
Due 19 June 2016
Resolved 1 July 2016
Resolution: [name withheld] INSPECTED.
Stability › Incline Test › General
Issued 19 May 2016
Resolved
obtain MSC approval of all wieght changes to date; incld liferaft reconfiguration.
Due 19 June 2016
Resolved 9 August 2016
Resolution: msc ser#H2-1602872
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 19 May 2016
Resolved
label indicators bow and stern each pilot house.
Condition: Improper Installation
Due 19 June 2016
Resolved 9 June 2016
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 19 May 2016
Resolved
create log or checksheet for all lifesaving equip inspections 46 CFR 199.190
Due 19 June 2016
Resolved 29 July 2016
Resolution: log sheet created see act docs
Electrical › Electrical Distribution System (service) › Switch
Issued 19 May 2016
Resolved
replace rescue boat light switch on deck at rescue boat.
Due 1 June 2016
Resolved 20 May 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 19 May 2016
Resolved
replace cable bow liferaft embark light on bowling alley cut sheathing/ cracked wasted.
Due 19 June 2016
Resolved 20 May 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 May 2016
Resolved
repair aft lifraft embark light will not hold posn.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2016
Resolved 20 May 2016
Resolution: repaired.