Records from 2008 to 2026. Most recent: inspection, 27 February 2026.
Inspection history · 51
27 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8317518
6 February 2025
Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8072268
18 October 2024
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8020975
18 October 2024
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8021229
6 September 2024
In-Service Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7997745
14 March 2024
Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7879265
29 September 2023
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7798032
3 August 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7759581
2 August 2023
Examination of Repairs · Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7751086
22 June 2023
Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7720563
22 May 2023
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7694205
12 October 2022
Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7576308
12 October 2022
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7576438
16 September 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7562113
7 September 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7553478
2 August 2022
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7534101
28 July 2022
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7519717
15 July 2022
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7507667
9 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7448660
3 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7296151
8 July 2021
Internal Structural Exam · Hull Examination · Construction Oversight · Deficiency Check · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7248341
27 April 2021
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7184851
22 April 2021
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7180439
21 October 2020
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7081859
24 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7058310
22 July 2020
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7012910
28 June 2020
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7006090
28 June 2020
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7007147
4 June 2020
Deficiency Check · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6967885
11 January 2020
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6888015
29 December 2019
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6880343
14 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855839
29 September 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6824289
28 August 2019
Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6796969
12 July 2019
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6744926
17 June 2019
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6716512
28 May 2019
Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6698033
10 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6469171
7 June 2018
Examination of Repairs · MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6423425
27 December 2017
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6337095
13 November 2017
Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6308263
22 September 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6272610
30 August 2017
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6255969
26 June 2017
Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6188107
17 April 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6128389
16 April 2017
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6126391
15 April 2017
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6134717
27 February 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6095543
10 November 2016
DAPI Audit · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6042170
8 March 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5829864
5 February 2016
Examination of Repairs · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5808060
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2026
Resolved
REMOVE DEADEND WIRES FROM FWD ENG. RM. BULKHEAD
Action required: 705 - Other - as specified
Resolved 15 April 2026
Resolution: CLEARED
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 August 2025
Resolved
Vessels exposed to saltwater for more than three months in any 12-month period must undergo a drydock examination at least once every two years. The vessel has not undergone the required drydock inspection within the prescribed interval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2025
Resolved 17 April 2026
Resolution: VSL Completed Credit Dry dock/ISE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2024
Resolved
Propulsion system and its necessary auxiliaries and controls must be arranged so that there are two sources of power. Propulsion controls are air powered and one of the two air compressors are inoperable. Prove proper operation of the inoperable air compressor to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2024
Resolved 18 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 August 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the operator shall be prepared to conduct tests of lifesaving equipment, including each rescue boat launching appliance. The rescue boat launching davit was inoperable upon inspection. Effect repairs ensure functionality to the satisfaction of the OCMI prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2023
Resolution: Engineers replaced launching davit limit switch; witness satisfactory operation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 May 2023
Resolved
Crop and renew longitudinal frames to good metal on both sides of the ladder in void #12, stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2023
Resolution: Completed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 May 2023
Resolved
Conduct UT gauging on the fwd bulkhead and deck of void #12 at next scheduled drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2023
Resolution: Result lead to crop and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 May 2023
Resolved
Crop and renew wasted deck beams around the hatch in the #12 void, stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2023
Resolution: Completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2022
Resolved
The owner, managing operator, or master shall report damage to a boiler, unfired pressure vessel, or machinery that renders further use of the item unsafe until repairs are made, to the OCMI as soon as practicable after the damage occurs. Vessel reported that the port engine shut down and the cause is undetermined. Determine source of loss of propulsion and affect repairs to the satisfaction of the Coast Guard Marine Inspector. A Technicians Report and or a sea trial may be required by the Coast Guard to clear this deficiency.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2022
Resolved 13 October 2022
Resolution: Completed sea trial and engine safety tests
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 September 2022
Resolved
A mechanical manually operated device to assist in launching a survival craft must be provided if the survival craft weighs more than 200 pounds and the survival craft requires lifting more than 1 vertical foot to be launched. Vessel reported that its rescue boat is unable to be manually launched, and can only be launched with ships power. Effect repairs to the satisfaction of the attending Marine Inspector. 46 CFR 180.130 (c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 September 2022
Resolution: OEM replaced brake assembly. Operational test witnessed by MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 July 2020
Resolved
Steering alarm panel inoperable. Make effective repairs to the satisfaction of Coast Guard Marine Inspector prior to sail.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 August 2020
Resolved 22 July 2020
Resolution: Replaced communication node. Alarms tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2020
Resolved
Prove proper operation of port generator to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2020
Resolved 24 June 2020
Resolution: Port generator rehauled and repaired to satisfaction of CG inspector
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 January 2020
Resolved
Vessel allied with barge and pier while mooring causing damage to the vessel on the stbd bow and rub rail. Make vessel available for inspection of damage prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 January 2020
Resolved 11 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 December 2019
Resolved
Failure of control air on main engine control on bridge.46 CFR 184.620
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 December 2019
Resolved 29 December 2019
Resolution: Found air filtration control filter faulty, and repaired line with leak, operational test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019
Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019
Resolved
All mattresses must comply with either 16 CFR Part 1632 Subpart A and not contain polyurethane foam or IMO Resolution A.688(17) and may contain polyurethane foam. Newly purchased mattresses on board do not meet either. 46 CFR 177.405(g)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Mattresses removed from vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2019
Resolved
Install lagging P/S for MDE's in #11 void.
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 3 September 2019
Resolution: Lagging installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2019
Resolved
Renew vent screens and caps as needed.
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 3 September 2019
Resolution: Screen installed in vents on deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2019
Resolved
Permanently repair cracked fuel fill piping to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 June 2018
Resolved
Conduct underway man overboard, fire and security drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2018
Resolved 10 July 2018
Resolution: Witnessed satisfactory drills.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2018
Resolved
Attach the #6 void high bilge alarm to the stanchion.
Action required: 10 - Deficiency Rectified
Due 20 June 2018
Resolved 20 June 2018
Engineering › Steering Gear System › Follow-up Assembly
Issued 13 November 2017
Resolved
FU / NFU port controller inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2017
Resolved 14 November 2017
Resolution: Tech repaired broken wire at FU / NFU controller power unit. CGMI witnessed repairs and testing of unit.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 September 2017
Resolved
Rescue boat was unbalanced when deployed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 1 November 2017
Resolution: SSA conducted safety check. All sat,
Operations/Management › Drills/Instruction › Fire
Issued 30 August 2017
Resolved
Conduct fire and man overboard drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 29 September 2017
Resolution: Drills conducted.
Engineering › Steering Gear System › Feedback Unit
Issued 16 April 2017
Resolved
PC Board possible failure, circuit bad.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 17 April 2017
Resolution: PC Board replaced, see tech report in file.
Operations/Management › Drills/Instruction › Fire
Issued 6 December 2016
Resolved
Conduct man overboard and fire drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 27 February 2017
Resolution: Witnessed a man overboard, fire, and security drill; all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 December 2016
Resolved
Make permanent repairs to CO2 piping where holed and wasted that leads to siren in the E/R. Test piping to 600 psi in the attendance of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 December 2016
Resolved
Prove proper operation of the port radar and gyro compass.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 December 2016
Resolved
Prove proper operation of all time delays on the CO2 systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Construction/Loadline › Structures › Deck Plating
Issued 10 November 2016
Resolved
main deck, aft in way of lazzerette and machinery space, holed/wasted, 2 locations, guage and renew plating as needed beam to beam at Jun 2017 yard availbility, doubler(s) accepted as temp repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 16 August 2017
Resolution: Area cropped and renewed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 February 2016
Resolved
Emergency light adjacent to crews head not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Engineering › Bilge Water Management System › Piping
Issued 18 February 2016
Resolved
Unable to take bilge suction from forepeak, bow thruster, and aft peak voids.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 February 2016
Resolved
Prove proper operation of bilge alarm in void #11.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Engineering › Bilge Water Management System › Piping
Issued 18 February 2016
Resolved
Demonstrate bilge suction in #4 void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 18 February 2016
Resolved
#2 SSDG low lube oil pressure shutdown not functioning. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 18 February 2016
Resolved
Demonstrate alarms and shutdowns for port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Stability › Watertight Integrity › General
Issued 18 February 2016
Resolved
Replace 3 WTD aft of house and chalk test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Lifesaving › Launching Appliances › Falls
Issued 18 February 2016
Resolved
Provide documentation for rescue boat davit falls and release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 February 2016
Resolved
Demonstrate fire and man overboard drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 8 March 2016
Resolution: Conducted satisfactory Man Overboard Fire drills.