MAURY USCG vessel records
← All vessels

TOM NEVERS

TOM NEVERS is a 1981 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 2016, most recently in February 2026, along with 38 deficiencies and 15 casualty investigations between 2008 and 2024.

Records from 2008 to 2026. Most recent: inspection, 27 February 2026.

Built
1981
Last inspected
27 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 February 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8123418
WCY2060
Flag
UNITED STATES
Maury page id
psix-53279

Documentation record

Registered dimensions (L × B × D)217.9 ft × 52.0 ft × 14.0 ft
Registered tonnagegross 99 / net 73
ITC dimensions (L × B × D)217.9 ft × 52.0 ft × 14.0 ft
ITC tonnagegross 1,277 / net 383
BuilderMOSS POINT MARINE INC · ESCATAWPA, MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW BEDFORD, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
1277 - Convention (Subpart B), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
383 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GREY LADY IV Passenger (Inspected) · MISLE 1337718 · 28 June 2020 · activity 7007147

Inspection history · 51

27 February 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8317518
6 February 2025 Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8072268
18 October 2024 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8020975
18 October 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8021229
6 September 2024 In-Service Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7997745
14 March 2024 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7879265
29 September 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7798032
3 August 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7759581
2 August 2023 Examination of Repairs · Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7751086
22 June 2023 Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7720563
22 May 2023 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7694205
12 October 2022 Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7576308
12 October 2022 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7576438
16 September 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7562113
7 September 2022 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7553478
2 August 2022 Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7534101
28 July 2022 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7519717
15 July 2022 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7507667
9 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7448660
3 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7296151
8 July 2021 Internal Structural Exam · Hull Examination · Construction Oversight · Deficiency Check · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7248341
27 April 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7184851
22 April 2021 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7180439
21 October 2020 Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7081859
24 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7058310
22 July 2020 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7012910
28 June 2020 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7006090
28 June 2020 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7007147
4 June 2020 Deficiency Check · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6967885
11 January 2020 Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6888015
29 December 2019 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6880343
14 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855839
29 September 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6824289
28 August 2019 Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6796969
12 July 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6744926
17 June 2019 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6716512
28 May 2019 Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6698033
10 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6469171
7 June 2018 Examination of Repairs · MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6423425
27 December 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6337095
13 November 2017 Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6308263
22 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6272610
30 August 2017 COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6255969
26 June 2017 Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6188107
17 April 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6128389
16 April 2017 Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6126391
15 April 2017 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6134717
27 February 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6095543
10 November 2016 DAPI Audit · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6042170
8 March 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5829864
5 February 2016 Examination of Repairs · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5808060

Deficiency record · 38

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2026 Resolved
REMOVE DEADEND WIRES FROM FWD ENG. RM. BULKHEAD
Action required: 705 - Other - as specified
Resolved 15 April 2026
Resolution: CLEARED
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 August 2025 Resolved
Vessels exposed to saltwater for more than three months in any 12-month period must undergo a drydock examination at least once every two years. The vessel has not undergone the required drydock inspection within the prescribed interval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2025
Resolved 17 April 2026
Resolution: VSL Completed Credit Dry dock/ISE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2024 Resolved
Propulsion system and its necessary auxiliaries and controls must be arranged so that there are two sources of power. Propulsion controls are air powered and one of the two air compressors are inoperable. Prove proper operation of the inoperable air compressor to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2024
Resolved 18 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 August 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the operator shall be prepared to conduct tests of lifesaving equipment, including each rescue boat launching appliance. The rescue boat launching davit was inoperable upon inspection. Effect repairs ensure functionality to the satisfaction of the OCMI prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2023
Resolution: Engineers replaced launching davit limit switch; witness satisfactory operation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 May 2023 Resolved
Crop and renew longitudinal frames to good metal on both sides of the ladder in void #12, stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2023
Resolution: Completed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 May 2023 Resolved
Conduct UT gauging on the fwd bulkhead and deck of void #12 at next scheduled drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2023
Resolution: Result lead to crop and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 May 2023 Resolved
Crop and renew wasted deck beams around the hatch in the #12 void, stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2023
Resolution: Completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2022 Resolved
The owner, managing operator, or master shall report damage to a boiler, unfired pressure vessel, or machinery that renders further use of the item unsafe until repairs are made, to the OCMI as soon as practicable after the damage occurs. Vessel reported that the port engine shut down and the cause is undetermined. Determine source of loss of propulsion and affect repairs to the satisfaction of the Coast Guard Marine Inspector. A Technicians Report and or a sea trial may be required by the Coast Guard to clear this deficiency.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2022
Resolved 13 October 2022
Resolution: Completed sea trial and engine safety tests
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 September 2022 Resolved
A mechanical manually operated device to assist in launching a survival craft must be provided if the survival craft weighs more than 200 pounds and the survival craft requires lifting more than 1 vertical foot to be launched. Vessel reported that its rescue boat is unable to be manually launched, and can only be launched with ships power. Effect repairs to the satisfaction of the attending Marine Inspector. 46 CFR 180.130 (c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 September 2022
Resolution: OEM replaced brake assembly. Operational test witnessed by MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 July 2020 Resolved
Steering alarm panel inoperable. Make effective repairs to the satisfaction of Coast Guard Marine Inspector prior to sail.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 August 2020
Resolved 22 July 2020
Resolution: Replaced communication node. Alarms tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2020 Resolved
Prove proper operation of port generator to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2020
Resolved 24 June 2020
Resolution: Port generator rehauled and repaired to satisfaction of CG inspector
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 January 2020 Resolved
Vessel allied with barge and pier while mooring causing damage to the vessel on the stbd bow and rub rail. Make vessel available for inspection of damage prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 January 2020
Resolved 11 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 December 2019 Resolved
Failure of control air on main engine control on bridge.46 CFR 184.620
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 December 2019
Resolved 29 December 2019
Resolution: Found air filtration control filter faulty, and repaired line with leak, operational test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019 Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019 Resolved
All mattresses must comply with either 16 CFR Part 1632 Subpart A and not contain polyurethane foam or IMO Resolution A.688(17) and may contain polyurethane foam. Newly purchased mattresses on board do not meet either. 46 CFR 177.405(g)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Mattresses removed from vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2019 Resolved
Install lagging P/S for MDE's in #11 void.
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 3 September 2019
Resolution: Lagging installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2019 Resolved
Renew vent screens and caps as needed.
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 3 September 2019
Resolution: Screen installed in vents on deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2019 Resolved
Permanently repair cracked fuel fill piping to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 June 2018 Resolved
Conduct underway man overboard, fire and security drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2018
Resolved 10 July 2018
Resolution: Witnessed satisfactory drills.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2018 Resolved
Attach the #6 void high bilge alarm to the stanchion.
Action required: 10 - Deficiency Rectified
Due 20 June 2018
Resolved 20 June 2018
Engineering › Steering Gear System › Follow-up Assembly
Issued 13 November 2017 Resolved
FU / NFU port controller inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2017
Resolved 14 November 2017
Resolution: Tech repaired broken wire at FU / NFU controller power unit. CGMI witnessed repairs and testing of unit.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 September 2017 Resolved
Rescue boat was unbalanced when deployed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 1 November 2017
Resolution: SSA conducted safety check. All sat,
Operations/Management › Drills/Instruction › Fire
Issued 30 August 2017 Resolved
Conduct fire and man overboard drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 29 September 2017
Resolution: Drills conducted.
Engineering › Steering Gear System › Feedback Unit
Issued 16 April 2017 Resolved
PC Board possible failure, circuit bad.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 17 April 2017
Resolution: PC Board replaced, see tech report in file.
Operations/Management › Drills/Instruction › Fire
Issued 6 December 2016 Resolved
Conduct man overboard and fire drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 27 February 2017
Resolution: Witnessed a man overboard, fire, and security drill; all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 December 2016 Resolved
Make permanent repairs to CO2 piping where holed and wasted that leads to siren in the E/R. Test piping to 600 psi in the attendance of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 December 2016 Resolved
Prove proper operation of the port radar and gyro compass.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 December 2016 Resolved
Prove proper operation of all time delays on the CO2 systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2016
Resolved 6 December 2016
Construction/Loadline › Structures › Deck Plating
Issued 10 November 2016 Resolved
main deck, aft in way of lazzerette and machinery space, holed/wasted, 2 locations, guage and renew plating as needed beam to beam at Jun 2017 yard availbility, doubler(s) accepted as temp repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 16 August 2017
Resolution: Area cropped and renewed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 February 2016 Resolved
Emergency light adjacent to crews head not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Engineering › Bilge Water Management System › Piping
Issued 18 February 2016 Resolved
Unable to take bilge suction from forepeak, bow thruster, and aft peak voids.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 February 2016 Resolved
Prove proper operation of bilge alarm in void #11.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Engineering › Bilge Water Management System › Piping
Issued 18 February 2016 Resolved
Demonstrate bilge suction in #4 void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 18 February 2016 Resolved
#2 SSDG low lube oil pressure shutdown not functioning. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 18 February 2016 Resolved
Demonstrate alarms and shutdowns for port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Stability › Watertight Integrity › General
Issued 18 February 2016 Resolved
Replace 3 WTD aft of house and chalk test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Lifesaving › Launching Appliances › Falls
Issued 18 February 2016 Resolved
Provide documentation for rescue boat davit falls and release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 25 February 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 February 2016 Resolved
Demonstrate fire and man overboard drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 8 March 2016
Resolution: Conducted satisfactory Man Overboard Fire drills.

Casualty record · 15

8 August 2008Routine · role: Involved in a Marine Casualty · activity 3297214
12 May 2009Routine · role: Involved in a Marine Casualty · activity 3475421
27 November 2010Routine · role: Involved in a Marine Casualty · activity 3902098
29 December 2010Routine · role: Involved in a Marine Casualty · activity 3919978
12 August 2012Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4414056
2 November 2012Routine · role: Involved in a Marine Casualty · activity 4481364
22 September 2013Routine · role: Involved in a Marine Casualty · activity 4742312
18 October 2013Routine · role: Involved in a Marine Casualty · activity 4742291
15 May 2015Routine · role: Alleged Pollution Source · activity 5128470
15 April 2017Routine · role: Involved in a Marine Casualty · activity 6134717
17 April 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6128389
28 June 2020Routine · role: Involved in a Marine Casualty · activity 7006090
28 June 2020Routine · role: Involved in a Marine Casualty · activity 7007147
12 October 2022Routine · role: Involved in a Marine Casualty · activity 7576438
18 October 2024Routine · role: Involved in a Marine Casualty · activity 8021229
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GAY HEAD (2008–2024). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.