SANKATY is a 1981 passenger vessel (inspected). The Coast Guard has recorded 174 inspections since 1981, most recently in May 2026, along with 196 deficiencies — 3 with no resolution recorded — and 17 casualty investigations between 2004 and 2025.

Records from 1981 to 2026. Most recent: inspection, 21 May 2026.

Built
1981
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8108030 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCE6015
Flag
UNITED STATES
366917530
Maury page id
psix-52800

Inspections, by type

…with no type recorded34
Years with a record 38 calendar years (1981–2026)
The 174 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)220.3 ft × 52.0 ft × 14.0 ft
Registered tonnagegross 749 / net 550
ITC dimensions (L × B × D)220.3 ft × 52.0 ft × 14.0 ft
ITC tonnagegross 1,315 / net 394
BuilderRYSCO SHIPYARD INC · BLOUNTSTOWN, FL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWOODS HOLE, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it749 - Regulatory (Subpart C or D), Gross Ton
1315 - Convention (Subpart B), Gross Ton
550 - Regulatory (Subpart C or D), Net Ton
394 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCE6015MMSI 366917530 · active · compulsorily equipped · granted 20 January 2024, expires 17 March 2034
EX147MMSI 366917530 · expired · exemption · granted 10 May 2010, cancelled 31 May 2014
EX120MMSI 366917530 · terminated · exemption · granted 15 December 2009, cancelled 14 January 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

Inspection history · 174

21 May 2026 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8377851
28 March 2026 Administrative Inspection · Vessel Attendance · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8333487
4 December 2025 COI Inspection · Examination of Repairs · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8277512
6 June 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8153825
8 May 2025 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8131038
31 January 2025 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8073068
31 January 2025 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8078292
29 October 2024 Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8022990
1 August 2024 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7972558
29 July 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8027762
24 July 2024 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7965993
29 April 2024 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7903642
11 March 2024 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7877235
12 January 2024 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7848812
14 December 2023 COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7834451
26 October 2023 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7809911
12 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7713792
10 November 2022 Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7583332
28 July 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7519422
24 January 2022 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7384881
24 January 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7385325
3 January 2022 Administrative Inspection · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7364530
9 November 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7348571
17 October 2021 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7334117
17 October 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7334821
26 August 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7361210
27 April 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7184832
8 December 2020 COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7109662
28 September 2020 DAPI Audit · MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7070223
10 August 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7019004
12 June 2020 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6983959
10 February 2020 COI Inspection · Examination of Repairs · MTSA Verification · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6907111
21 November 2019 Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6856532
14 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855852
10 July 2019 MTSA Verification · DAPI Audit · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6742903
8 April 2019 MTSA Verification · Periodic Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6649680
8 April 2019 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6658256
11 March 2019 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6640955
4 October 2018 Examination of Repairs · Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6557688
7 August 2018 MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6503535
18 May 2018 Administrative Inspection · MTSA Verification · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6412005
2 January 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6331495
19 December 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6326771
18 December 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6326012
13 November 2017 Examination of Repairs · COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6306699
8 November 2017 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6327382
12 October 2017 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6282526
19 April 2017 Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6128277
2 February 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6081936
31 January 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6080104
21 December 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6060969
9 December 2016 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6057796
7 December 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6113690
7 December 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6113805
17 November 2016 MTSA Verification · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6042296
3 August 2016 Deadweight Survey · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5963143
6 June 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5909080
4 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5869455
4 May 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878661
1 April 2016 Re-Inspection · Deficiency Check · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5845552
23 November 2015 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5770407
3 November 2015 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5756283
21 September 2015 DAPI Audit · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5724496
25 June 2014 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4914831
22 May 2014 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4870557
27 March 2014 MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4824584
6 July 2012 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4381968
7 June 2012 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4333287
4 December 2011 Damage Survey · MTSA Verification · Examination of Repairs · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4201612
4 December 2011 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4202482
1 September 2011 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4133625
1 September 2011 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4133922
28 July 2011 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4096782
28 January 2011 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3936357
11 January 2011 COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3924583
26 October 2010 Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3878808
30 March 2010 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3723152
11 March 2010 COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3694415
29 January 2009 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3402561
23 January 2009 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3425284
18 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3382148
17 October 2008 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3346546
30 September 2008 Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3336169
6 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3290987
31 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3284985
7 July 2008 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3260497
2 July 2008 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3240541
31 March 2008 Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3171679
17 March 2008 Administrative Inspection
Administrative · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3166748
13 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3163525
13 February 2008 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3146835
24 January 2008 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3135789
16 November 2007 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3110783
23 October 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3086289
6 September 2007 Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3051673
24 May 2007 Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2919211
23 February 2007 Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2875119
18 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2781339
15 September 2006 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2776594
7 June 2006 Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2650546
31 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2666278
30 May 2006 Construction Oversight
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2665299
12 April 2006 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2622777
6 March 2006 Administrative Inspection
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2597157
17 February 2006 COI Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2587034
17 October 2005 Hull Examination · Deadweight Survey · COI Inspection · Construction Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2518557
19 September 2005 Re-Inspection · Administrative Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2488222
1 June 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2374893
23 March 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2316624
14 March 2005 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2331296
14 March 2005 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2331318
28 January 2005 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2287815
27 January 2005 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2289125
14 October 2004 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2220030
11 June 2004 Administrative Inspection
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2095508
29 April 2004 Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2054800
18 February 2004 Damage Survey
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2009755
2 February 2004 Damage Survey
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1998558
30 January 2004 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2000300
7 January 2004 Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1977376
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977608
14 October 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1932241
23 September 2003 COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1910301
14 March 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1757427
30 January 2003 Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1737150
25 January 2003 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1758791
12 December 2002 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1717966
21 November 2002 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1707809
23 October 2002 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1694454
6 July 2002 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1684000
6 July 2002 Damage Survey
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1694003
2 May 2002 Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1612599
4 March 2002 Construction Oversight
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1491348
31 January 2002 Quarterly Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1483279
17 December 2001 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1475902
16 October 2001 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1454986
4 October 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1074728
30 March 2001 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1066462
15 February 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1436513
25 October 2000 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1418785
12 April 2000 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 816772
29 October 1999 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 796156
26 October 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1471725
25 March 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 54197
19 February 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1129686
20 November 1998 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1429081
28 July 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 799371
17 February 1998 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 778119
23 January 1998 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 779440
12 January 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 775162
14 May 1997 COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1109398
10 September 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 69869
14 May 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1088288
5 February 1996 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872099
25 January 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879367
30 October 1995 Re-Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 879360
8 September 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1404004
25 July 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 875744
18 July 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 9806
22 June 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1390092
6 June 1995 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 874977
10 April 1995 Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1181358
5 May 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 74094
23 March 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1469428
7 June 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1465750
20 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015551
15 October 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300900
20 September 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992001
13 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284395
13 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288453
27 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972552
11 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275253
13 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963294
14 September 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276175

Deficiency record · 196

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 February 2025 No resolution recorded
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. A temporary repair to a horizontal fractured weld was accepted above the starboard side MDE exhaust penetration at the side shell. During inspection is was noted that there is additional wastage on the side shell at the welds between the exhaust piping and side shell and in way of the existing welds for a previous insert. Crop and renew this section of the side shell to good metal prior to next credit drydock in the fall of 2025.
Action required: 705 - Other - as specified
Due 31 December 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 November 2024 Resolved
The emergency generator set must shut down automatically upon loss of lubricating oil pressure, overspeed, or operation of a fixed fire extinguishing system in the emergency generator room. The EDG will not shutdown by means of the CO2 pressure switch. Prove proper operation to the satisfaction of the attending USCG MI prior to 06Jan24.
Action required: 705 - Other - as specified
Due 6 January 2025
Resolved 19 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2024 Resolved
The emergency generator set must shut down automatically upon loss of lubricating oil pressure, overspeed, or operation of a fixed fire extinguishing system in the emergency genrator room. The EDG will not shutdown by means of the CO2 pressure switch or low lube oil pressure. Prove proper operation to the satisfaction of the attending USCG MI prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2024
Resolved 14 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2024 Resolved
In addition to the emergency power sources required under 46 CFR part 112, each self-propelled vessel must have at least two electric generating sources. #1 SSDG is not operable. Prove proper operation of the #1 SSDG to the satisfaction of the USCG MI prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2024
Resolved 19 November 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2024 No resolution recorded
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. A temporary repair consisting of a doubler plate at the exhaust piping penetration through the deck for the #1 SSDG in the port side exhaust stack has been approved. Crop and renew wasted area of the deck to good metal prior to next credit drydock.
Action required: 705 - Other - as specified
Due 31 December 2026
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2024 No resolution recorded
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. A temporary repair consisting of a doubler wear plate on the Port and Starboard side stern of the vehicle deck where the transfer bridge rests has been approved. Crop and renew worn section of the vehicle deck to good metal prior to next credit drydock.
Action required: 705 - Other - as specified
Due 31 December 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2024 Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The installed gauges on the 02 air receivers, aft engine room, are out of this range for the 200 PSI relief devices. Provide gauges IAW with regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2024
Resolution: New gauges were installed
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 July 2024 Resolved
A current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. The current deviation card allows for a 6 degree deviation. the magnetic compass displayed a heading of 180 while the gyro compass and GPS displayed a heading of 164.1 degrees. This does not meet the 6 degree deviation. Determine the cause of the reason for the discrepancy in deviation and take corrective action.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 August 2024
Resolution: Received a copy of new deviation card
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024 Resolved
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. Vessels port main governor is not operating as designed. Vessel is authorized to make one time transit to Fairhaven, MA via Hyannis, MA to make repairs to governor. No passengers or cargo is authorized on transit. Vessel to complete repairs to the satisfaction of attending CGMI prior to return to service.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 May 2024
Resolved 7 May 2024
Resolution: Governor was replaced, Vessel sea trials were conducted in the presence of a CGMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2024 Resolved
Vessel's rudders shift 4-5 degrees while shifting from the non-follow up to follow up steering mode while rudder are in the midship position. Diagnose and complete repairs to ensure steering is in proper operating order.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2024
Resolution: EMI Technician recalibrated system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 January 2024 Resolved
Drawings of alterations shall be approved before work is started, unless deemed unnecessary by the Officer in Charge, Marine Inspection. Submit drawings for the ventilation modifications for the emergency generator space to USCG Marine Safety Center for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2024
Resolved 26 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 January 2024 Resolved
The emergency power source must meet table 112.05–5(a) and have the capacity to supply all loads that are simultaneously connected to it. Prove proper operation of the emergency generator to the satisfaction of the attending USCG MI prior to carrage of passengers. Emergency generator is overheating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2024
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 12 June 2023 Resolved
Deviations from rules and reporting: Non-operating equipment.(a) If during a voyage any equipment required by this part stops operating properly, the person directing the movement of the vessel may continue to the next port of call, subject to the directions of the District Commander or the Captain of the Port, as provided by part 160 of this chapter. Vessel reported loss of steering due to number two steering pump 24vdc power supply failure. Vessel is authorized a one time transit from Nantucket to Hyannis, MA. to affect repairs to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2023
Resolution: 13JUNE2023 - Attended vessel. Witnessed operation of steering system in all modes after replacement of the number two steering pump 24vdc power supply; all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 November 2022 Resolved
Relocate CO2 siren in E/R to face upwards and clean out trap to face downwards to avoid debris being collected in siren prior to completion of COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 29 November 2022
Resolution: Piping set up properly
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 November 2022 Resolved
Update fire control plan and submit to local OCMI for review, verification, and approval to reflect installation of the new fire detection system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 30 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 November 2022 Resolved
Vessel only has one 128-person life raft on board. Reduce total persons allowed on vessel to 191 till two other life rafts are placed on board.
Action required: 705 - Other - as specified
Resolved 29 November 2022
Resolution: All life rafts installed on board
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 November 2022 Resolved
Fire door FSD-2 not properly latching. Fix to satisfaction of CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 29 November 2022
Resolution: Fire door repaired
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 17 November 2022 Resolved
Properly label newly installed fire alarms.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 2 December 2022
Resolution: Fire alarms labeled
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 November 2022 Resolved
Replace proximity switch for watertight door #5.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 2 December 2022
Resolution: Switch repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2022 Resolved
Label fire extinguisher box IVO fire station #6.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 29 November 2022
Resolution: Fire extinguisher box labeled
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 November 2022 Resolved
Submit "as built" drawings for fire detection system to MSC for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 26 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2022 Resolved
Properly service fire extinguisher on rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Fire extinguisher serviced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 November 2022 Resolved
Submit fire detection system tech report and have CG marine inspector check system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Tech report submitted and tested smoke/heat detectors
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 July 2022 Resolved
If a pipe, scupper, or electric cable passes through a main transverse watertight bulkhead, the opening through which is passes must be watertight. Cable penetrations found at bulkhead 7 leading into engine room were found not watertight. In addition, penetration found aft engine room bulkhead also found not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo of item completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2022 Resolved
No repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. A pipe fitting for #3 remote watertight door actuation was found welded, repair must be made in accordance with approved plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 12 August 2022
Resolution: RCVD photos of satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2022 Resolved
Each battery-operated lantern must remain fully charged, and capable of providing light for at least three hours, 10 emergency lanterns were found non-operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received a photo of e-lights working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2022 Resolved
Instructions in at least 1/2 inch letters shall be posted in the steering engine room, relating in order, the different steps to be taken in changing to the emergency steering gear. Instructions were not present at steering gear location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 12 August 2022
Resolution: RCVD photos of satisfactory posting of instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2022 Resolved
Install and test remote shutdown for the fuel oil purifier as per approved plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2022
Resolved 3 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 January 2022 Resolved
The main steering gear and rudder stock must be capable of moving the rudder from 35° on either side to 35° on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed. Vessel's crew reports that at cruising speed, the steering gear becomes "stuck" at 25° port rudder, and cannot return to amidship unless the vessels throttle is reduced. Effect repairs to the satisfaction of the attending Marine Inspector prior to movement. (No Sail) *** Vessel is authorized a one time transit from Woods Hole MA to Fairhaven MA.*** 46 CFR 58.25-10(b)(2)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 24 February 2022
Resolved 26 January 2022
Resolution: Adjusted relief valve setting on rudder hydraulic pump & crossover relief valve within manufacturer's spec; satisfactory sea trial complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2022 Resolved
Rescue boat is missing fire extinguisher. Place fire extinguisher on board rescue boat.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 7 January 2022
Resolution: Fire extinguisher mounted on board rescue boat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 January 2022 Resolved
General alarm in bow thruster space is missing placard. Post placard near general alarm bell.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 7 January 2022
Resolution: Placard posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2022 Resolved
Provide approved plans for fuel oil purifier prior to placing in service.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 4 April 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 January 2022 Resolved
Pull handle to access control for fixed fire system in emergency generator space is broken. Fix prior to getting underway.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 January 2022
Resolution: New pull handle installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 October 2021 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire fighting or other equipment or whenever repairs or renewals are made. Vessel experienced failure of its #1 Ship Service Generator. Effect repairs to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 October 2021
Resolved 18 October 2021
Resolution: Vessel replaced number 2 genertor digital and analog voltage regulator, and conducted testing to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 January 2021 Resolved
Obtain plan approval from MSC of Rev A of dwg Firemain Cross Over Relief Valve Installation 3233-180.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021
Resolved 8 February 2021
Resolution: plan appvd by uscg msc.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 January 2021 Resolved
Verify AC and DC approved electrical dwgs correctly reflect what is installed on the vessel; verify modifications/installations on the vessel are IAW the approved dwgs to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2021
Resolved 25 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 December 2020 Resolved
Newly installed bow thruster firemain relief valve cannot prevent the firemain from being over pressurized. Provide an acceptable solution to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 25 January 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 December 2020 Resolved
Batteries were dead in the emergency lights in the passagway leading to the engine room. Prove proper operation of the emergency lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 4 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2020 Resolved
Air start actuator for the port MDE is leaking excessively, prove proper operation of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 December 2020 Resolved
Provide sign for CO2 siren in the bow thruster space “When alarm sounds vacate at once. Carbon Dioxide being released”
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 December 2020 Resolved
Emergency light in passageway outside of crew quarters is dim/failed light bulb. Make repairs to emergency light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2020 Resolved
Make repairs to bilge suction for void #7 and retest to the satisfaction of the attending USCG Marine Inspector. Suction could not be obtained from this space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 December 2020 Resolved
Prove proper operation of emergency stop button for the EDG. Button is not functioning.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 8 December 2020 Resolved
Rescue boat davit winch does not meet lowering speeds as required by 46 CFR 199.153(h)-(j). Make repairs to rescue boat davit winch to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 8 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2020 Resolved
Properly install or remove hanging LED light stbd side aft on the air receiver. Is hung up by wire ties and rigged with extension cord.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 19 November 2020 Resolved
A LAUNCHING APPLIANCE MUST NOT DEPEND ON ANY MEANS OTHER THAN GRAVITY TO LAUNCH THE SURVIVAL CRAFT IT SERVES IN ALL CONDITIONS. RESCUE BOAT LAUNCHING APPLIANCE NOT ABLE TO LOWER THE RESCUE BOAT IN A LIGHT CONDITION BY RELEASING THE BRAKE/GRAVITY.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2020 Resolved
Oil leak on the port governor must be fixed to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2020
Resolved 30 June 2020
Resolution: [name withheld] TRIAL OLD GOVERNOR REPAIRED RE-INSTALLED.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 March 2020 Resolved
FIRE MAIN DOES NOT HAVE A PRESSURE RELIEF VALVE INSTALLED. NEEDED FOR SECONDARY(MONITOR) PUMP. MAIN FIRE PUMP IN COMPLIANCE. INSTALL BY 1NOV20.
Action required: 705 - Other - as specified
Due 1 November 2020
Resolved 29 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020 Resolved
PSTP(S) DO NOT REFLECT ALL ANNUAL TESTING REQUIRED. CONSOLIDATE, AMMEND, SUBMIT TO OCMI FOR LOCAL APPROVAL. BY 10MAY20.
Action required: 705 - Other - as specified
Due 10 May 2020
Resolved 4 March 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 February 2020 Resolved
Repair or replace the inoperative door handle to the interior door to the stair tower from the second deck the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2020 Resolved
Install/provide a smoke detector IWO the pilots stateroom. Must meet UL 217.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2020 Resolved
Replace the inoperative emergency light on the 02 deck exterior, IWO the port aft accommodation door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 February 2020 Resolved
Provide one additional (2 total) lifeline for the emergency gear locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 February 2020 Resolved
DVTP/PSTP FOR BOW THRUSTER/2ND FIRE PUMP NOT APPROVED OBTAIN APPROVED DVTP PSTP. REF MSC LTR 20FEB E2-2000596.
Action required: 705 - Other - as specified
Due 6 April 2020
Resolved 4 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020 Resolved
DVTP/PSTP FOR STEERING SYSTEM NOT APPROVED. OBTAIN APPROVED DVTP/PSTP. CORRECT DVTP TO REFLECT PSTP PROCD 6.19.5/6.29.5, REMOVE SAME FROM PSTP. UPDATE ELECTRICAL DWG FOR RESISTER MOD SUBMIT WITH DVTP.
Action required: 705 - Other - as specified
Due 6 April 2020
Resolved 8 April 2020
Resolution: approved Steering Gear System drawings, updated DVTP and PSTP USCG Approval Letter # E2-2001261 dated 4/8/2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020 Resolved
A/C ONE-LINE DOES NOT REFLECT CURRENT INSTALLATION, OBTAIN APPROVED UPDATED AC ON-LINE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2020
Resolved 25 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020 Resolved
STEERING GEAR BREAKER OVERSIZE FOR CONDUCTOR, CORRECT. SPECIFY CORRECT ON ONE-LINE. ENSURE SAME MEETS LOCK ROTOR CURRENT CAPACITIES AS SPECIFIED BY 46 CFR 58.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2020
Resolved 23 March 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 10 February 2020 Resolved
EMERGENCY STEERING CONTROL BOX, PUMP #2 COMMAND JOY STICK WIRED BACKWARD. (STICK TO PORT RUDDER MOVE STBD AND VICE VERSA)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2020
Resolved 23 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2019 Resolved
Complete testing of approved FEMA/DVTP for the bow thruster control system in the presence of Sector South East New England marine inspectors. Vessel is authorized to transit without passenger from New London, CT to Faihaven, MA.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2020
Resolved 4 March 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019 Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2019 Resolved
Steering system failure.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2019
Resolved 25 March 2019
Resolution: Steering system has been upgraded.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 October 2018 Resolved
Provide guards or other suitable means to prevent injury to personnel around the main propulsion shafts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 October 2018 Resolved
Hydro test fire hoses and test fire monitor to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 October 2018 Resolved
Prove proper operation of anchors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 October 2018 Resolved
Conduct u/w man overboard, security, and fire drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 19 December 2017 Resolved
Prior to operating starboard engine make repairs to prevent loss of coolant to the satisfaction to the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2017
Resolved 19 December 2017
Resolution: Witnessed satisfactory operation of the starboard main engine.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston Ring
Issued 18 December 2017 Resolved
Vessel's stbd main engine does not work as designed due to a possible blown head gasket and cooling leak. Vessel is to repair the starboard main engine and demonstrate to the satisfaction of a Coast Guard Marine Inspector. Vessel was transiting from Vineyard Haven, MA to Woods Hole, MA at time of loss of propulsion.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2017
Resolved 18 December 2017
Resolution: Vessel replaced head gasket for the #4 cylinder head and proved proper operation to CG.
Operations/Management › Drills/Instruction › Fire
Issued 11 December 2017 Resolved
Conduct underway fire, man overboard, abandon ship and security drills.
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 2 January 2018
Resolution: Drills have been conducted satisfactory.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 November 2016 Resolved
Conduct underway man overboard fire, man overboard and security drills.
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 21 December 2016
Resolution: Attended vessel to witness drills; all sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 November 2016 Resolved
Update the fire control plans, fuel tank location, fuel shut off's and life preserver storage and submit for review approval to Sec SENE
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 31 January 2017
Engineering › Lubricating Oil Service System › Piping
Issued 3 August 2016 Resolved
Repair lube oil leak in way of starboard lube oil regulator valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2016
Resolved 23 November 2016
Lifesaving › Launching Appliances › Falls
Issued 3 August 2016 Resolved
Canduct 1.1 weight test of rescue boat/davit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2016
Electrical › Electric Generation Source (service) › Generator
Issued 4 May 2016 Resolved
Generator windings have been damaged due to a piece of metal getting caught up in the windings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2016
Resolved 4 May 2016
Resolution: Ships force replaced generator end.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 April 2016 Resolved
AVH02: life jacket access in handicap passenger area is not accessible. Make access more accessible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 23 November 2016
Construction/Loadline › Structures › Superstructure
Issued 1 April 2016 Resolved
AVH01: Crack in frieght deck, provide report of final repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 19 April 2016
Resolution: Crack has been welded.
Lifesaving › Launching Appliances › Davit
Issued 29 October 2015 Resolved
Perform rescue boat full weight test, limit switch, and demonstrate proper operation of the rescue boat.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2015
Resolved 2 November 2015
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 October 2015 Resolved
Provide written request for equivalant level of safety or move fixed fire extinguishing controls outside the emergency generator space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2015
Resolved 2 November 2015
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 October 2015 Resolved
Conduct MOB, Fire, and Security drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 November 2015
Resolved 23 November 2015
Resolution: Conducted satisfactory man overboard, fire, abandon ship and security drills.
Deck/Cargo › Cargo Stowage › General
Issued 16 February 2012 Resolved
Ensure vehicles are secured at each end while vessel is navigating IAW 46 CFR 78.40-5.
Action required: 705 - Other - as specified
Due 16 February 2012
Resolved 16 February 2012
Resolution: Vehicles were chocked on return run to Woods Hole. Deficiency cleared.
Construction/Loadline › Hull › Hull Plating
Issued 4 December 2011 Resolved
Starboard bow bulwarks turned in 8-10 inches, cap pipe seperated iwo mast base. Make permanent repairs w/ in 30 days.
Action required: 705 - Other - as specified
Due 6 January 2012
Resolved 7 June 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 1 September 2011 Resolved
Repair and test port main engine to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2011
Resolved 2 September 2011
Resolution: Engine over speed device was repaired.
Communications › Radio Communications › EPIRB
Issued 28 July 2011 Resolved
Renew registration for EPIRB IAW 46 CFR 199.510.
Action required: 705 - Other - as specified
Due 4 August 2011
Resolved 28 July 2011
Resolution: Port captain provided documentation that the EPIRB registration was current.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 28 July 2011 Resolved
Renew lifting straps for rescue boat IAW 46 CFR 199.160
Action required: 705 - Other - as specified
Due 28 August 2011
Resolved 16 September 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 October 2010 Resolved
Address location of CO2 manual activation handle to prevent contact with water tight door.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2011
Resolved 20 January 2011
Resolution: Added door stop to prevent the WTD from contacting the CO2 handle. New handle installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 October 2010 Resolved
Repair rail netting on 01 level.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2011
Resolved 20 January 2011
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 26 October 2010 Resolved
Make first 10' of anchor chain available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2011
Resolved 25 January 2011
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2010 Resolved
Make repairs to leaking tie downs on car deck over #3 void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2011
Resolved 20 January 2011
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 12 March 2010 Resolved
Demonstrate steering alarms. Hydraulic level and loss of power at motor controller.
Action required: 705 - Other - as specified
Due 12 April 2010
Resolved 12 April 2010
Resolution: WITTNESSED LOSS OF POWER, ACCEPTED WRITTEN LOG C/E CONDUCTED LOW LEVEL.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 March 2010 Resolved
Label all E lights in Machinery space.
Action required: 705 - Other - as specified
Due 12 April 2010
Resolved 12 April 2010
Resolution: CORRECTED.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 March 2010 Resolved
Conduct operational drills (MOB, Fire, Abandon Ship).
Action required: 705 - Other - as specified
Due 12 April 2010
Resolved 12 April 2010
Resolution: CONDUCTED SAT.
Electrical › Electric Generation Source (service) › Generator
Issued 12 March 2010 Resolved
Provide amended DVTP/PSTP for newly installed gensets.
Action required: 705 - Other - as specified
Due 12 April 2010
Resolved 12 April 2010
Resolution: PROVIDED TO [name withheld], STAMPED COPY ADDED TO VSL FILE.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 March 2010 Resolved
Prove proper operation of Emergency "exit" signs on 01 deck.
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 24 March 2010
Stability › Incline Test › General
Issued 17 October 2008 Resolved
PROVIDE ONBOARD VALID STABILITY LETTER BASED ON NEW DOWN FLOODING CALCULATIONS, REF MSC LTR h2-0801353
Condition: Improper/Lack of Maintenance
Due 4 December 2008
Resolved 4 December 2008
Resolution: Provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 17 October 2008 Resolved
RENEW CO2 PIPING BOW THRUSTER SYSTEM. TEST PIPING TO 600PSI, AN OPERATIONALLY TEST SYSTEM TO ATTENDING USCG MARINE INSPECTOR. VESSEL TO BE OUTOF SERVICE AT ANY TIME THIS SYTEM IS NOT OPERATIONAL. PIPING AS INSTALLED ACCEPTED AS TEMPORARY.
Condition: Improper Installation
Due 18 December 2008
Resolved 18 December 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 October 2008 Resolved
FIRE CONTROL PLAN OUTDATED DOES NOT REFLECT CURRENT GA. POSE UPDATED FCP ON VESSEL.
Condition: Improper/Lack of Maintenance
Due 15 January 2009
Resolved 12 March 2010
Personnel › Training › Crisis Management/Human Behaviour
Issued 17 October 2008 Resolved
CONDUCT OPERATIONAL DRILLS TO SAT OF ATTENDING MI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 December 2008
Resolved 18 December 2008
Resolution: Witnessed satisfactory drills.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 October 2008 Resolved
RE-STENCIL EMERGENCY ESCAPE HATCH ER AND LAZERETTE FOR STEERING. BOTH LOCATED ON FRIEGHT DECK.
Condition: Improper/Lack of Maintenance
Due 21 November 2008
Resolved 22 November 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 October 2008 Resolved
RE-STENCIL EMERGENCY ESCAPE HATCH ER AND LAZERETTE FOR STEERING. BOTH LOCATED ON FRIEGHT DECK.
Condition: Improper/Lack of Maintenance
Due 21 November 2008
Resolved 22 November 2008
Electrical › Electric Supply System (service) › Cable
Issued 17 October 2008 Resolved
SAFE END OR REMOVE UNUSED WIRES STBD ER.
Condition: Improper/Lack of Maintenance
Due 4 November 2008
Resolved 4 November 2008
Engineering › Diesel Engine (auxiliary) › Governor
Issued 17 October 2008 Resolved
TACH FOR GENERATOR PRIME MOVER NOT OPERATIONAL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Fire Fighting › Fire Pumps › Suction Valve
Issued 17 October 2008 Resolved
MAIN FIRE PUMP STRAINER BASKET COVER FRACTURED LEAKING. REPAIR/REPLACE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Resolution: WELDED UP.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 17 October 2008 Resolved
EXCESS LEAKAGE PACKING GLAND. ADD PACKING REMOVE PLASTIC "CATCH TRAYS".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Resolution: ADDED PACKING, FABRICATED STAINLESS CATCH TRAYS.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 October 2008 Resolved
REPAIR/MARK ALL E-LIGHTS IWO OF TUNNEL.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Engineering › Compressed Air System (start air) › Control Gear
Issued 17 October 2008 Resolved
REPAIR START AIR BUTTON LOCAL CONTROL STBD MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 17 October 2008 Resolved
LABEL EMERGENCY ESCAPE HATCH ON FRIEGHT DECK, WIDEN BOARDER TO AVOID VEHICLE BLOCKAGE. SAME FOR LAZERETTE HATCH FOR E-STEERING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 December 2008
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 October 2008 Resolved
ELECTRIC INDICATOR NOT ON E-POWER.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Resolution: INSTALLED MANUAL INDICATOR.
Construction/Loadline › Structures › Door
Issued 17 October 2008 Resolved
REPAIR/REPLACE WEATHERTIGHT DOOR FWD 01 DECK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Construction/Loadline › Structures › Door
Issued 17 October 2008 Resolved
REPAIR WASTED SILL FSD, MAIN DECK AFT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 17 October 2008 Resolved
REPLACE BLACK IRON A106 SEAMLESS PIPE AND AS105 FORGED STEEL FITTING WITH GALVANIZED PIPING AND FITTINGS P/APPROVED PLANS. TEST CURRENT INSTALLATION TO 600 PSI TO SAT OF ATTENDING INSPECTOR BY JAN 15, 2009, REPLACE NON GALVINIZED COMPONENTS BY NLT JAN 1, 2010.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 30 January 2009
Resolution: Pipe and fittings replaced with galvanized piping and fittings IAW approved plans. Bulkhead penetration replaced with 1.25" pipe and packed with approved fire stop.
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 17 March 2008 Resolved
In accordance with MSC letter 16710/P008804 (Serial: H2-0800626) dated 27 Feb 08 (attached) the Naval architect shall provide updated damage stability calculations demonstrating compliance with the applicable stability requirements of 46 CFR Subchapter S. New calculations are required due to; 1) the new installation of engine room intake and exhaust vents & bow thruster vent. Sent to MSC 24MAR08
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 20 November 2008
Resolution: NEW REQ ISSUED TO REFLECT STAB LTR ONBOARD IN 2WKS.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 March 2008 Resolved
In accordance with 46 CFR 71.65-10; A Fire Control Plan must be updated to reflect the new installation of the engine room intake and exhaust vents, closures and controls during dry dock Nov 07; and 2) the addition of a bow thruster room vent, closures and controls marked examined 27 Feb 08.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 20 November 2008
Resolution: NEW REQ ISSUED REQ UPDATED FCP POSTED IN TWO WEEKS.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 March 2008 Resolved
In accordance with MSC letter 16710/P08804/tlg (Serial: E1-0701658) dated 05 Jun 2006 paragraph 4 (attached); A General Arrangement Plan must be updated to reflect the ventilation changes and indicate ventilation controls. Update to reflect; 1) the new installation of engine room intake and exhaust vents and controls during dry dock Nov 07; 2) the addition of a bow thruster room vent and controls
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 20 November 2008
Resolution: PLANS SUBMITTED AND APPROVED, EMERGENCY ESCAPE AND SFP.
Fire Fighting › Ventilation Systems › Fans
Issued 17 March 2008 Resolved
Bow Thruster; Final installation of the ventilation fan and deck goose neck vent w/closure requires final OCMI approval by an attending USCG Marine Inspector. In addition, the fix fire fighting CO2 pneumatic ventilation shutdown switch was tested and activated satisfactory; a final test - manual lifting of the CO2 pneumatic switch and verification of the new ventilation fan shut down is required.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 July 2008
Resolution: Attended vessel and verified as satisfactory this date.
Operations/Management › Drills/Instruction › Fire
Issued 16 November 2007 Resolved
Complete a fire and MOB drill to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 24 January 2008
Resolution: Completed this date,
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 October 2007 Resolved
Repair or replace the swash bulkheads in the P&S ballast tanks located between frames 55 & 65.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 December 2007
Resolution: Stbd side to be completed at next availablity (with in one year)
Engineering › Reduction Gearing/Clutches › Shrink-Fit Rings
Issued 23 October 2007 Resolved
Repair lube oil leaks on the P&S red gears.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 20 December 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 October 2007 Resolved
Repair or replace fwd 01 deck fire door.
Due 31 December 2007
Resolved 26 December 2007
Resolution: repaired
Construction/Loadline › Hull › Hull Plating
Issued 23 October 2007 Resolved
Provide as built drawings for repairs to muffler space side shell, P & S.
Action required: 705 - Other - as specified
Resolved 31 July 2008
Resolution: Attended vessel and verified as satisfactory this date.
Accommodation/Occupational Safety › Ventilation › General
Issued 23 October 2007 Resolved
Verify installation of e/r fans as per MSC letter dated June 5, 2007.
Due 31 December 2007
Resolved 26 December 2007
Resolution: All sat
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 May 2007 Resolved
Rescue boat non operational. Crew incompetent resulting in a failed drill.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2007
Resolved 24 May 2007
Resolution: Passed another attempt later in the day to satisfaction of Supervisor MSD CC
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 24 May 2007 Resolved
Engine Room escape hatch not marked for escape hatch nor stenciled as reqiured
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 24 May 2007
Resolution: Remarked this date.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 May 2007 Resolved
Fire door to galley equipped with illegal holdbacks and broken door threshold resulting in an inoperative door. This to be fixed prior to commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 24 May 2007
Resolution: Corrected this date to satisfaction of MSD CC Supervisor.
Lifesaving › Launching Appliances › Davit
Issued 15 September 2006 Resolved
Rescue boat davit found inoperable. Repair to satisfaction of USCG prior to resuming commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 18 September 2006
Resolution: Boarded vessel and found davit had been fully overhauled this date.
Construction/Loadline › Penetrations › Weld
Issued 30 May 2006 Resolved
Provide MSC approved plans for installation of new engine room escape hatch. Include weld procedure, weldment specifications, and welder certifications.
Due 9 June 2006
Resolved 31 May 2006
Resolution: Completed this date
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 May 2006 Resolved
Paint deck hatch and stencil with designation to not obstruct. Yellow background with black letters "Escape Hatch" "Keep Clear".
Due 9 June 2006
Resolved 31 May 2006
Resolution: Verified as done this date
Lifesaving › Launching Appliances › Davit
Issued 10 April 2006 Resolved
Rescue boat davit limit switch found out of adjustment allowing rescue boat to be placed under hull overhang while recovering baot due to operator inattention to his duties. Repair no later than 1300 on April 11 2006.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Resolution: Done
Lifesaving › Launching Appliances › Falls
Issued 10 April 2006 Resolved
Rescue boat davit found with broken and bent releasing wire support bracket. Repair no later than Friday 14 April
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 7 June 2006
Resolution: Found to be repaired satisfactory this date
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 April 2006 Resolved
Upper deck missing "no passengers" labeling as required by vessel stability letter.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Resolution: Done
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 April 2006 Resolved
Engine room escape hatch missing "escape hatch, do not obstruct" labeling.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Resolution: Done
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 April 2006 Resolved
Crew size is inadequate for intended route and service. Crew size is recommended to be increased by one (1) Ordinary Sseaman.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 12 February 2007
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 February 2006 Resolved
Approved General Arrangements plan has not been received from MSC. Provide no later than 24 March 2006 to MSD Cape Cod.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 15 September 2006
Resolution: Found satisfactory this date.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 17 February 2006 Resolved
Re-write the vessel operations manual to reflect the vessels latest major modifications.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 15 September 2006
Resolution: Found satisfactory this date.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 February 2006 Resolved
Obtain a written exemption letter from Commander D1 for 46/199.202, rescue boat no later than March 24 2006.
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 7 March 2006
Resolution: Exemtion letter received this date and included in vessel e-files.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 October 2005 Resolved
Re-submit as built drawings to the vessel's OCMI for approval, for the following system: F/W system, Bow thruster exhaust piping installation, Hydraulic watertight door and the electrical equipment arrangement.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Engineering › Fuel Oil Service System › Piping
Issued 17 October 2005 Resolved
Properly re-route the emergency generator f/o supply line and conduct a pressure test.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2006
Resolved 9 February 2006
Engineering › Lubricating Oil Service System › Piping
Issued 17 October 2005 Resolved
Remove the existing L/O system piping, valves and sight glass IAW the approved drawing
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 9 February 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 October 2005 Resolved
Provide approved drawings Electrical 2500 (E-1 & 5) and the bilge piping mod.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 17 October 2005 Resolved
Port and starboard void tanks, fwd of frame 32 has weep holes installed that are not shown on the drawing. Make the necessary changes or correction.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 27 February 2006
Resolution: Completed this date
Lifesaving › Rescue Boat › Hull (rigid)
Issued 17 October 2005 Resolved
Based on the new gross tonnage, the vessel is now required to carry two rescue boats as per 46 CFR 199.202. Issue must be resolved by the local OCMI prior to the carriage of passenger and/or cargo.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 7 March 2006
Resolution: Exemtion letter received this date and included in vessel e-files.
Navigation › Piloting/Steering › Magnetic Compass
Issued 17 October 2005 Resolved
Magnetic Compass is more than 50 deg. off. Calibrate compass and provide updated deveation table.
Condition: Improper/Lack of Maintenance
Due 9 February 2006
Resolved 9 February 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 October 2005 Resolved
New Sliding Watertight Doors are using the Gyro Compass backup batteries for emergency source of power. Gyro Compass is a vital navigational device and requires a separate source of power as per 46 CFR 111.60.9. Remove Sliding WTD's from circuit and provide another source of power for WTD's.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 March 2006
Resolution: Completed this date
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 October 2005 Resolved
Repair or Replace #4 Bilge sensor and demonstrate proper operation to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 9 February 2006
Resolved 9 February 2006
Communications › Internal Communications System › Sound-powered Telephone
Issued 17 October 2005 Resolved
Repair sound powered phone buzzer in aft steering space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 October 2005 Resolved
Bow Thruster Engine Day Tank fuel supply line is not equipped with a remote control fuel shut off valve. Install new remote control fuel shut off valve and demonstrate proper operation to the attending Coast Guard Marine Inspector and update drawing to reflect the change.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 October 2005 Resolved
Port MDE day fuel oil tank remote fuel shut off valve required assistance of pipe wrench to close. All other remote fuel shut off valves were in poor condition and required excessive force to close. Perform Maintenance on all remote fuel shut off valves and demonstrate proper operation to the Attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2006
Resolution: Completed this date
Engineering › Compressed Air System (start air) › Compressor
Issued 17 October 2005 Resolved
Starting air compressor will not start on automatic, trouble shoot and make repairs, demonstrate proper operation to Attending Coast Guard Marine Inspector
Condition: Improper/Lack of Maintenance
Due 9 February 2006
Resolved 9 February 2006
Documentation › Certificates/Documents › Stability Letter
Issued 17 October 2005 Resolved
Provide an approved Stability Letter .
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2006
Resolution: Recieved this date.
Electrical › Electric Generation Source (service) › Generator
Issued 17 October 2005 Resolved
Conduct an Electrical System Load Analysis due to additional equipment installed during major modification. Provide report to Attending Coast Guard Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Electrical › Electric Generation Source (service) › Generator
Issued 17 October 2005 Resolved
Repair or Replace automatic voltage regulators for both Ship Service Generators. Demonstrate proper operation to Attending Coast Guard Marine Inspector. Auto voltage regulators are slow to respond or do not respond to load changes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 October 2005 Resolved
Wire runs on both port and starboard side of aft bulkhead in engine room have plastic wire ties holding wire runs in place. Remove plastic wire ties and replace with metal wire straps to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Improper Installation
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 17 October 2005 Resolved
Demonstrate proper operation of Main Diesel and Ship Service Generator Engine low lube oil, high jacket water alarms and MDE over speed shutdown devices in the presence of Attending Coast Guard Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 17 October 2005 Resolved
Marine Reduction Gear back up oil pumps failed during initial test, blowing out seals and improper operation. Demonstrate proper operation of reduction gear backup oil pumps in presence of Attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 27 February 2006
Resolution: Completed this date
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 October 2004 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILL AND UNDERWAY VESSEL OPERATIONS.
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 14 December 2004
Resolution: DRILLS COMPLETED SAT.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 11 June 2004 Resolved
1. Provide training manual in accordance with 46 CFR 199.180, with emphasis on procedures for launching and recovering rescue boats.
Due 31 October 2004
Resolved 1 June 2005
Resolution: TRAINING MANUAL PROVIDED.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 June 2004 Resolved
2. Submit muster list format for OCMI approval in accordance with 46 CFR 199.217
Due 31 October 2004
Resolved 1 June 2005
Resolution: MUSTER LIST PROVIDED.
Lifesaving › Rescue Boat
Issued 18 February 2004 Resolved
Prior to tcarriage of passengers make permenent repairs to damaged electrical feed cable to rescue boat davit.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2004
Resolution: Cable replaced in kind.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 30 January 2004 Resolved
PROCEED TO SHIPYARD AND MAKE PERMANENT REPAIRS TO THE STARBOARD SHAFT. SEA TRIALS TO BE CONDUCT IN PRESENCE OF A USCG INSPECTOR PRIOR TO RESUMPTION OF SERVICE.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2004
Resolved 9 February 2004
Resolution: REPLACEMENT SHAFT INSTALLED AND SEA TRAILS COMPLETED SAT.
Engineering › Reduction Gearing/Clutches
Issued 14 October 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2003
Resolved 28 October 2003
Resolution: REDUCTION GEAR REPAIRED AND UNDERWAY TESTS SAT.
Engineering › Fuel Oil Storage/Transfer System
Issued 23 September 2003 Resolved
REPLACE FLAME SCREENS FOR THE LUBE OIL AND DIRTY OIL TANKS.
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 15 December 2003
Resolution: Screens replaced, [name withheld].
Construction/Loadline › Structures
Issued 23 September 2003 Resolved
LABEL ALL VENTS ON DECK. LEGACY COMPONENT DESC: Ventilators
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 15 December 2003
Resolution: [name withheld], [name withheld]
Personnel › Manning/Qualifications
Issued 30 January 2003 Resolved
PROVIDE A COPY OF THE SHIP'S LOGS AND COMPLETE PAY RECORDS FOR ALL REQUIRED PERSONNEL ASSIGNED TO THE VESSEL FOR THE WEEK OF 23-30 JAN 03. RECORDS ARE TO BE DELIVERED TO THE SENIOR INVESTIGATOR, MSO PROVIDENCE, NO LATER THAN 15 FEB 03. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 14 March 2003
Resolution: SHIPS LOG AND RECORDS DELIVERED TO MSO PROVIDENCE.
Engineering › Bilge Water Management System
Issued 23 October 2002 Resolved
Replace Eductor Pipe to Forepeak/Chain Locker. Section of pipe is on the Focs'l Deck under the raised deck. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 2 December 2002
Resolved 8 November 2002
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 May 2002 Resolved
REPLACE BETTERIES IN EMERGENCY LIGHTING ABOVE SWITCHBOARD IN ENGINEROOM.
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 2 May 2002
Resolution: BATTERIES REPLACED.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2001 Resolved
REPLACE PLASTIC TRASH CANS WITH APPROVED INCOMBUSTIBLE TYPE AS REQUIRED BY 46 CFR 72.05-55(b). LEGACY COMPONENT DESC: Trash bins
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2001
Resolved 16 October 2001
Resolution: As per agreement between vessel operators and CID MSO Providence, all interior trash cans replaced with incombustible type and exterior trash cans allowed to be plastic.
Lifesaving › Rescue Boat
Issued 16 October 2001 Resolved
CONDUCT SATISFACTORY FIRE AND MAN OVERBOARD DRILL. LEGACY COMPONENT DESC: drills
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2001
Resolved 16 October 2001
Resolution: All drills conducted sat.
Construction/Loadline › Structures
Issued 16 October 2001 Resolved
ADJUST ALL WATER TIGHT DOORS TO CLOSE AND SEAL PROPERLY. LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2001
Resolved 16 October 2001
Resolution: All watertight and weather doors tested sat.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 16 October 2001 Resolved
PROVIDE PROOF OF TESTING OF MAIN ENGINE, S/S GENS AND BOW THRUSTER ENGINE TEMERATURE SENSORS. LEGACY COMPONENT DESC: ALARMS AND SHUTDOWNS
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2001
Resolved 17 December 2001
Resolution: Vessel chief engineer provided paperwork of all alarms and shutdown tests sat. Random checked several alarms, all tested sat.
Construction/Loadline
Issued 15 February 2001 Resolved
Make #4 P/S ballast tanks ready for coast guard marine inspector. No commercial activity allowed until this requirement is cleared.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Lifesaving
Issued 23 January 1998 Resolved
Within the next thirty days, conduct underway drills to the satisfaction ofthe attending Marine Inspector.
Condition: Unknown
Due 17 February 1998
Resolved 18 February 1998
Engineering
Issued 12 January 1998 Resolved
PROPERLY SAND BLAST AND PAINT THE F/O VENT PIPES.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Deck/Cargo
Issued 12 January 1998 Resolved
CROP OUT AND RENEW DONUT COLLAR FROM CHAIN LOCKER TO ANCHOR WINDLASS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Construction/Loadline
Issued 12 January 1998 Resolved
RENEW BILGE STRAINER ON THE #5 STBD AFT BALLAST TANK BILGE ROSE BOX.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Navigation
Issued 14 May 1997 Resolved
REPAIR SOUND POWERED PHONES IN STEERING STATION AND AUXILIARY ROOM.
Condition: Unknown
Due 23 June 1997
Resolved 15 September 1997
Electrical
Issued 14 May 1997 Resolved
REPAIR EMERGENCY EXIT LIGHT ON MAIN DECK AFT ACCOMODATION AREA.
Condition: Unknown
Due 23 June 1997
Resolved 15 September 1997
Engineering
Issued 14 May 1997 Resolved
REPLACE HANDLIFTING HANDLE FOR RELIEF VALVE ON PORT AIR RECEIVER.
Condition: Unknown
Due 23 June 1997
Resolved 15 September 1997
Lifesaving
Issued 14 May 1996 Resolved
CONDUCT ANNUAL SERVICING OF VESSELS LIFE RAFTS.
Condition: Unknown
Due 14 May 1996
Resolved 20 August 1996
Lifesaving
Issued 14 May 1996 Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 14 May 1996
Resolved 20 August 1996
Engineering
Issued 14 May 1996 Resolved
REBUILT VESSEL'S PORT AND STARBOARD REDUCTION GEARS INCLUDING REPLACEMENT OF BEARINGS.
Condition: Unknown
Due 14 May 1996
Resolved 20 August 1996
Construction/Loadline
Issued 25 January 1996 Resolved
Gas free and make available for internal inspection by USCG inspector MSD/sewage holding tank and fresh water tank.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Navigation
Issued 30 October 1995 Resolved
PROPERLY SHOCK MOUNT THE AFTER STERN LIGHT TO PREVENT FILAMENT OUTAGE.
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Accommodation/Occupational Safety
Issued 25 July 1995 Resolved
PROVIDE HAND GRAB RAILS AT FORE AND AFT FRAME EDGE FOR PORT AND STARBOARD EMBARKATION DOORS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 August 1995
Resolved 18 September 1995
Lifesaving
Issued 10 April 1995 Resolved
CONDUCT A FIRE AND BOAT DRILL NOT LATER THAN 24APR95.
Condition: Unknown
Due 24 April 1995
Resolved 22 May 1995
Electrical
Issued 20 September 1985 Resolved
PROVE OPERATION OF ALLEYWAY EMERGENCY LIGHT.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Engineering
Issued 20 September 1985 Resolved
LIFT SAFTIES AND PROVIDE FOR INTERNAL INSPECTION TWO PRESSURE VESSELS IN ENGINE ROOM.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Navigation
Issued 20 September 1985 Resolved
PROVE OPERATION OF LORAN C.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Engineering
Issued 20 September 1985 Resolved
PROVE OPERATION OF BOW THRUSTER.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Construction/Loadline
Issued 20 September 1985 Resolved
PROVE OPERATION OF BILGE AND BALLAST SYSTEM INCLUDING RELATED PUMPS, VALVESAND PIPING.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Engineering
Issued 20 September 1985 Resolved
PROVE OPERATION OF MAIN ENGINES, ASSOCIATED ALARM AND FUEL SYSTEMS.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Unknown
Issued 13 November 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL INSIGNIA DN640565
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Deck/Cargo
Issued 13 November 1984 Resolved
REINSTALL OPERABLE PNEUMATIC ACTIVATORS ON FUEL SYSTEM MANIFOLD BUTTERFLY VALVES.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Navigation
Issued 13 November 1984 Resolved
RECALIBRATE RUDDER ANGLE INDICATOR IN PILOT HOUSE SO THAT IT READS ACCURAT-ELY WITH NO STICKING.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Engineering
Issued 13 November 1984 Resolved
PROVIDE RELIEF VALVES FOR BOTH AIR RECEIVERS WHICH ARE SET AT OR BELOW TANKMAWP.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Navigation
Issued 13 November 1984 Resolved
REPAIR SOUND POWERED PHONE IN STEERING COMPARTMENT.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Unknown
Issued 13 September 1983 Resolved
(REQUIREMENT E2 CONTINUED) COAST GUARD INSPECTOR
Condition: Unknown
Due 13 September 1983
Resolved 13 September 1983
Unknown
Issued 13 September 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAINS TO THE VESSEL INSIGNIA, DN640565.
Condition: Unknown
Due 13 September 1983
Resolved 13 September 1983
Engineering
Issued 13 September 1983 Resolved
REMOVE FROM SERVICE THE PORT ENGINE START AIR RECEIVER UNTIL THE RELIEF VALVE OR SAME HAS BEEN SATISFACTORILY TESTED IN THE PRESENCE OF A
Condition: Unknown
Due 13 September 1983
Resolved 13 September 1983

Casualty record · 17

30 January 2004Routine · role: Involved in a Marine Casualty · activity 2000300
27 January 2005Routine · role: Involved in a Marine Casualty · activity 2289125
14 March 2005Routine · role: Involved in a Marine Casualty · activity 2331318
28 January 2011Routine · role: Involved in a Marine Casualty · activity 3936357
1 September 2011Routine · role: Involved in a Marine Casualty · activity 4133625
25 November 2013Routine · role: Involved in a Marine Casualty · activity 4758971
22 May 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4870557
4 May 2016Routine · role: Involved in a Marine Casualty · activity 5878661
6 June 2016Routine · role: Involved in a Marine Casualty · activity 5909080
7 December 2016Routine · role: Involved in a Marine Casualty · activity 6113690
7 December 2016Routine · role: Involved in a Marine Casualty · activity 6113805
8 November 2017Routine · role: Involved in a Marine Casualty · activity 6327382
8 April 2019Routine · role: Involved in a Marine Casualty · activity 6658256
17 October 2021Routine · role: Involved in a Marine Casualty · activity 7334821
24 January 2022Routine · role: Involved in a Marine Casualty · activity 7385325
29 July 2024Routine · role: Involved in a Marine Casualty · activity 8027762
31 January 2025Routine · role: Involved in a Marine Casualty · activity 8078292
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.