SANKATY is a 1981 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 2016, most recently in May 2026, along with 75 deficiencies — 3 with no resolution recorded — and 17 casualty investigations between 2004 and 2025.

Records from 2004 to 2026. Most recent: inspection, 21 May 2026.

Built
1981
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8108030
WCE6015
Flag
UNITED STATES
Maury page id
psix-52800

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded11
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)220.3 ft × 52.0 ft × 14.0 ft
Registered tonnagegross 749 / net 550
ITC dimensions (L × B × D)220.3 ft × 52.0 ft × 14.0 ft
ITC tonnagegross 1,315 / net 394
BuilderRYSCO SHIPYARD INC · BLOUNTSTOWN, FL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWOODS HOLE, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it749 - Regulatory (Subpart C or D), Gross Ton
1315 - Convention (Subpart B), Gross Ton
550 - Regulatory (Subpart C or D), Net Ton
394 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ISLAND HOME Passenger (Inspected) · MISLE 832132 · 26 August 2021 · activity 7361210

Inspection history · 60

21 May 2026 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8377851
28 March 2026 Administrative Inspection · Vessel Attendance · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8333487
4 December 2025 COI Inspection · Examination of Repairs · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8277512
6 June 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8153825
8 May 2025 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8131038
31 January 2025 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8073068
31 January 2025 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8078292
29 October 2024 Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8022990
1 August 2024 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7972558
29 July 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8027762
24 July 2024 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7965993
29 April 2024 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7903642
11 March 2024 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7877235
12 January 2024 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7848812
14 December 2023 COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7834451
26 October 2023 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7809911
12 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7713792
10 November 2022 Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7583332
28 July 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7519422
24 January 2022 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7384881
24 January 2022 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7385325
3 January 2022 Administrative Inspection · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7364530
9 November 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7348571
17 October 2021 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7334117
17 October 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7334821
26 August 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7361210
27 April 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7184832
8 December 2020 COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7109662
28 September 2020 DAPI Audit · MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7070223
10 August 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7019004
12 June 2020 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6983959
10 February 2020 COI Inspection · Examination of Repairs · MTSA Verification · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6907111
21 November 2019 Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6856532
14 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855852
10 July 2019 MTSA Verification · DAPI Audit · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6742903
8 April 2019 MTSA Verification · Periodic Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6649680
8 April 2019 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6658256
11 March 2019 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6640955
4 October 2018 Examination of Repairs · Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6557688
7 August 2018 MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6503535
18 May 2018 Administrative Inspection · MTSA Verification · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6412005
2 January 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6331495
19 December 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6326771
18 December 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6326012
13 November 2017 Examination of Repairs · COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6306699
8 November 2017 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6327382
12 October 2017 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6282526
19 April 2017 Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6128277
2 February 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6081936
31 January 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6080104
21 December 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6060969
9 December 2016 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6057796
7 December 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6113690
7 December 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6113805
17 November 2016 MTSA Verification · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6042296
3 August 2016 Deadweight Survey · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5963143
6 June 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5909080
4 May 2016 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5869455
4 May 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878661
1 April 2016 Re-Inspection · Deficiency Check · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5845552

Deficiency record · 75

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 February 2025 No resolution recorded
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. A temporary repair to a horizontal fractured weld was accepted above the starboard side MDE exhaust penetration at the side shell. During inspection is was noted that there is additional wastage on the side shell at the welds between the exhaust piping and side shell and in way of the existing welds for a previous insert. Crop and renew this section of the side shell to good metal prior to next credit drydock in the fall of 2025.
Action required: 705 - Other - as specified
Due 31 December 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 November 2024 Resolved
The emergency generator set must shut down automatically upon loss of lubricating oil pressure, overspeed, or operation of a fixed fire extinguishing system in the emergency generator room. The EDG will not shutdown by means of the CO2 pressure switch. Prove proper operation to the satisfaction of the attending USCG MI prior to 06Jan24.
Action required: 705 - Other - as specified
Due 6 January 2025
Resolved 19 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2024 Resolved
The emergency generator set must shut down automatically upon loss of lubricating oil pressure, overspeed, or operation of a fixed fire extinguishing system in the emergency genrator room. The EDG will not shutdown by means of the CO2 pressure switch or low lube oil pressure. Prove proper operation to the satisfaction of the attending USCG MI prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2024
Resolved 14 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2024 Resolved
In addition to the emergency power sources required under 46 CFR part 112, each self-propelled vessel must have at least two electric generating sources. #1 SSDG is not operable. Prove proper operation of the #1 SSDG to the satisfaction of the USCG MI prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2024
Resolved 19 November 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2024 No resolution recorded
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. A temporary repair consisting of a doubler plate at the exhaust piping penetration through the deck for the #1 SSDG in the port side exhaust stack has been approved. Crop and renew wasted area of the deck to good metal prior to next credit drydock.
Action required: 705 - Other - as specified
Due 31 December 2026
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2024 No resolution recorded
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. A temporary repair consisting of a doubler wear plate on the Port and Starboard side stern of the vehicle deck where the transfer bridge rests has been approved. Crop and renew worn section of the vehicle deck to good metal prior to next credit drydock.
Action required: 705 - Other - as specified
Due 31 December 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2024 Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The installed gauges on the 02 air receivers, aft engine room, are out of this range for the 200 PSI relief devices. Provide gauges IAW with regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2024
Resolution: New gauges were installed
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 July 2024 Resolved
A current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. The current deviation card allows for a 6 degree deviation. the magnetic compass displayed a heading of 180 while the gyro compass and GPS displayed a heading of 164.1 degrees. This does not meet the 6 degree deviation. Determine the cause of the reason for the discrepancy in deviation and take corrective action.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 August 2024
Resolution: Received a copy of new deviation card
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024 Resolved
An inspection, either general or partial depending upon the circumstances, shall be made whenever any important repairs or alterations are undertaken. Vessels port main governor is not operating as designed. Vessel is authorized to make one time transit to Fairhaven, MA via Hyannis, MA to make repairs to governor. No passengers or cargo is authorized on transit. Vessel to complete repairs to the satisfaction of attending CGMI prior to return to service.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 May 2024
Resolved 7 May 2024
Resolution: Governor was replaced, Vessel sea trials were conducted in the presence of a CGMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2024 Resolved
Vessel's rudders shift 4-5 degrees while shifting from the non-follow up to follow up steering mode while rudder are in the midship position. Diagnose and complete repairs to ensure steering is in proper operating order.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2024
Resolution: EMI Technician recalibrated system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 January 2024 Resolved
Drawings of alterations shall be approved before work is started, unless deemed unnecessary by the Officer in Charge, Marine Inspection. Submit drawings for the ventilation modifications for the emergency generator space to USCG Marine Safety Center for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2024
Resolved 26 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 January 2024 Resolved
The emergency power source must meet table 112.05–5(a) and have the capacity to supply all loads that are simultaneously connected to it. Prove proper operation of the emergency generator to the satisfaction of the attending USCG MI prior to carrage of passengers. Emergency generator is overheating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2024
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 12 June 2023 Resolved
Deviations from rules and reporting: Non-operating equipment.(a) If during a voyage any equipment required by this part stops operating properly, the person directing the movement of the vessel may continue to the next port of call, subject to the directions of the District Commander or the Captain of the Port, as provided by part 160 of this chapter. Vessel reported loss of steering due to number two steering pump 24vdc power supply failure. Vessel is authorized a one time transit from Nantucket to Hyannis, MA. to affect repairs to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2023
Resolution: 13JUNE2023 - Attended vessel. Witnessed operation of steering system in all modes after replacement of the number two steering pump 24vdc power supply; all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 November 2022 Resolved
Relocate CO2 siren in E/R to face upwards and clean out trap to face downwards to avoid debris being collected in siren prior to completion of COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 29 November 2022
Resolution: Piping set up properly
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 November 2022 Resolved
Update fire control plan and submit to local OCMI for review, verification, and approval to reflect installation of the new fire detection system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 30 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 November 2022 Resolved
Vessel only has one 128-person life raft on board. Reduce total persons allowed on vessel to 191 till two other life rafts are placed on board.
Action required: 705 - Other - as specified
Resolved 29 November 2022
Resolution: All life rafts installed on board
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 November 2022 Resolved
Fire door FSD-2 not properly latching. Fix to satisfaction of CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 29 November 2022
Resolution: Fire door repaired
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 17 November 2022 Resolved
Properly label newly installed fire alarms.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 2 December 2022
Resolution: Fire alarms labeled
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 November 2022 Resolved
Replace proximity switch for watertight door #5.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 2 December 2022
Resolution: Switch repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2022 Resolved
Label fire extinguisher box IVO fire station #6.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 29 November 2022
Resolution: Fire extinguisher box labeled
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 17 November 2022 Resolved
Submit "as built" drawings for fire detection system to MSC for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 26 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2022 Resolved
Properly service fire extinguisher on rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Fire extinguisher serviced
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 November 2022 Resolved
Submit fire detection system tech report and have CG marine inspector check system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Tech report submitted and tested smoke/heat detectors
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 July 2022 Resolved
If a pipe, scupper, or electric cable passes through a main transverse watertight bulkhead, the opening through which is passes must be watertight. Cable penetrations found at bulkhead 7 leading into engine room were found not watertight. In addition, penetration found aft engine room bulkhead also found not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo of item completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2022 Resolved
No repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. A pipe fitting for #3 remote watertight door actuation was found welded, repair must be made in accordance with approved plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 12 August 2022
Resolution: RCVD photos of satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2022 Resolved
Each battery-operated lantern must remain fully charged, and capable of providing light for at least three hours, 10 emergency lanterns were found non-operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received a photo of e-lights working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2022 Resolved
Instructions in at least 1/2 inch letters shall be posted in the steering engine room, relating in order, the different steps to be taken in changing to the emergency steering gear. Instructions were not present at steering gear location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 12 August 2022
Resolution: RCVD photos of satisfactory posting of instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2022 Resolved
Install and test remote shutdown for the fuel oil purifier as per approved plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2022
Resolved 3 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 January 2022 Resolved
The main steering gear and rudder stock must be capable of moving the rudder from 35° on either side to 35° on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed. Vessel's crew reports that at cruising speed, the steering gear becomes "stuck" at 25° port rudder, and cannot return to amidship unless the vessels throttle is reduced. Effect repairs to the satisfaction of the attending Marine Inspector prior to movement. (No Sail) *** Vessel is authorized a one time transit from Woods Hole MA to Fairhaven MA.*** 46 CFR 58.25-10(b)(2)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 24 February 2022
Resolved 26 January 2022
Resolution: Adjusted relief valve setting on rudder hydraulic pump & crossover relief valve within manufacturer's spec; satisfactory sea trial complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2022 Resolved
Rescue boat is missing fire extinguisher. Place fire extinguisher on board rescue boat.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 7 January 2022
Resolution: Fire extinguisher mounted on board rescue boat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 January 2022 Resolved
General alarm in bow thruster space is missing placard. Post placard near general alarm bell.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 7 January 2022
Resolution: Placard posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2022 Resolved
Provide approved plans for fuel oil purifier prior to placing in service.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 4 April 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 January 2022 Resolved
Pull handle to access control for fixed fire system in emergency generator space is broken. Fix prior to getting underway.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 January 2022
Resolution: New pull handle installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 October 2021 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its life-saving appliances, fire fighting or other equipment or whenever repairs or renewals are made. Vessel experienced failure of its #1 Ship Service Generator. Effect repairs to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 October 2021
Resolved 18 October 2021
Resolution: Vessel replaced number 2 genertor digital and analog voltage regulator, and conducted testing to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 January 2021 Resolved
Obtain plan approval from MSC of Rev A of dwg Firemain Cross Over Relief Valve Installation 3233-180.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021
Resolved 8 February 2021
Resolution: plan appvd by uscg msc.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 January 2021 Resolved
Verify AC and DC approved electrical dwgs correctly reflect what is installed on the vessel; verify modifications/installations on the vessel are IAW the approved dwgs to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2021
Resolved 25 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 December 2020 Resolved
Newly installed bow thruster firemain relief valve cannot prevent the firemain from being over pressurized. Provide an acceptable solution to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 25 January 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 December 2020 Resolved
Batteries were dead in the emergency lights in the passagway leading to the engine room. Prove proper operation of the emergency lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 4 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2020 Resolved
Air start actuator for the port MDE is leaking excessively, prove proper operation of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 December 2020 Resolved
Provide sign for CO2 siren in the bow thruster space “When alarm sounds vacate at once. Carbon Dioxide being released”
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 December 2020 Resolved
Emergency light in passageway outside of crew quarters is dim/failed light bulb. Make repairs to emergency light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2020 Resolved
Make repairs to bilge suction for void #7 and retest to the satisfaction of the attending USCG Marine Inspector. Suction could not be obtained from this space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 December 2020 Resolved
Prove proper operation of emergency stop button for the EDG. Button is not functioning.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 8 December 2020 Resolved
Rescue boat davit winch does not meet lowering speeds as required by 46 CFR 199.153(h)-(j). Make repairs to rescue boat davit winch to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 8 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2020 Resolved
Properly install or remove hanging LED light stbd side aft on the air receiver. Is hung up by wire ties and rigged with extension cord.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2020
Resolved 29 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 19 November 2020 Resolved
A LAUNCHING APPLIANCE MUST NOT DEPEND ON ANY MEANS OTHER THAN GRAVITY TO LAUNCH THE SURVIVAL CRAFT IT SERVES IN ALL CONDITIONS. RESCUE BOAT LAUNCHING APPLIANCE NOT ABLE TO LOWER THE RESCUE BOAT IN A LIGHT CONDITION BY RELEASING THE BRAKE/GRAVITY.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2020 Resolved
Oil leak on the port governor must be fixed to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2020
Resolved 30 June 2020
Resolution: [name withheld] TRIAL OLD GOVERNOR REPAIRED RE-INSTALLED.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 March 2020 Resolved
FIRE MAIN DOES NOT HAVE A PRESSURE RELIEF VALVE INSTALLED. NEEDED FOR SECONDARY(MONITOR) PUMP. MAIN FIRE PUMP IN COMPLIANCE. INSTALL BY 1NOV20.
Action required: 705 - Other - as specified
Due 1 November 2020
Resolved 29 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2020 Resolved
PSTP(S) DO NOT REFLECT ALL ANNUAL TESTING REQUIRED. CONSOLIDATE, AMMEND, SUBMIT TO OCMI FOR LOCAL APPROVAL. BY 10MAY20.
Action required: 705 - Other - as specified
Due 10 May 2020
Resolved 4 March 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 February 2020 Resolved
Repair or replace the inoperative door handle to the interior door to the stair tower from the second deck the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2020 Resolved
Install/provide a smoke detector IWO the pilots stateroom. Must meet UL 217.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2020 Resolved
Replace the inoperative emergency light on the 02 deck exterior, IWO the port aft accommodation door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 February 2020 Resolved
Provide one additional (2 total) lifeline for the emergency gear locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 4 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 February 2020 Resolved
DVTP/PSTP FOR BOW THRUSTER/2ND FIRE PUMP NOT APPROVED OBTAIN APPROVED DVTP PSTP. REF MSC LTR 20FEB E2-2000596.
Action required: 705 - Other - as specified
Due 6 April 2020
Resolved 4 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020 Resolved
DVTP/PSTP FOR STEERING SYSTEM NOT APPROVED. OBTAIN APPROVED DVTP/PSTP. CORRECT DVTP TO REFLECT PSTP PROCD 6.19.5/6.29.5, REMOVE SAME FROM PSTP. UPDATE ELECTRICAL DWG FOR RESISTER MOD SUBMIT WITH DVTP.
Action required: 705 - Other - as specified
Due 6 April 2020
Resolved 8 April 2020
Resolution: approved Steering Gear System drawings, updated DVTP and PSTP USCG Approval Letter # E2-2001261 dated 4/8/2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020 Resolved
A/C ONE-LINE DOES NOT REFLECT CURRENT INSTALLATION, OBTAIN APPROVED UPDATED AC ON-LINE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2020
Resolved 25 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020 Resolved
STEERING GEAR BREAKER OVERSIZE FOR CONDUCTOR, CORRECT. SPECIFY CORRECT ON ONE-LINE. ENSURE SAME MEETS LOCK ROTOR CURRENT CAPACITIES AS SPECIFIED BY 46 CFR 58.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2020
Resolved 23 March 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 10 February 2020 Resolved
EMERGENCY STEERING CONTROL BOX, PUMP #2 COMMAND JOY STICK WIRED BACKWARD. (STICK TO PORT RUDDER MOVE STBD AND VICE VERSA)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2020
Resolved 23 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2019 Resolved
Complete testing of approved FEMA/DVTP for the bow thruster control system in the presence of Sector South East New England marine inspectors. Vessel is authorized to transit without passenger from New London, CT to Faihaven, MA.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2020
Resolved 4 March 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019 Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2019 Resolved
Steering system failure.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2019
Resolved 25 March 2019
Resolution: Steering system has been upgraded.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 18 October 2018 Resolved
Provide guards or other suitable means to prevent injury to personnel around the main propulsion shafts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 October 2018 Resolved
Hydro test fire hoses and test fire monitor to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 October 2018 Resolved
Prove proper operation of anchors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 October 2018 Resolved
Conduct u/w man overboard, security, and fire drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2018
Resolved 29 October 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 19 December 2017 Resolved
Prior to operating starboard engine make repairs to prevent loss of coolant to the satisfaction to the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2017
Resolved 19 December 2017
Resolution: Witnessed satisfactory operation of the starboard main engine.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston Ring
Issued 18 December 2017 Resolved
Vessel's stbd main engine does not work as designed due to a possible blown head gasket and cooling leak. Vessel is to repair the starboard main engine and demonstrate to the satisfaction of a Coast Guard Marine Inspector. Vessel was transiting from Vineyard Haven, MA to Woods Hole, MA at time of loss of propulsion.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2017
Resolved 18 December 2017
Resolution: Vessel replaced head gasket for the #4 cylinder head and proved proper operation to CG.
Operations/Management › Drills/Instruction › Fire
Issued 11 December 2017 Resolved
Conduct underway fire, man overboard, abandon ship and security drills.
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 2 January 2018
Resolution: Drills have been conducted satisfactory.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 November 2016 Resolved
Conduct underway man overboard fire, man overboard and security drills.
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 21 December 2016
Resolution: Attended vessel to witness drills; all sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 November 2016 Resolved
Update the fire control plans, fuel tank location, fuel shut off's and life preserver storage and submit for review approval to Sec SENE
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 31 January 2017
Engineering › Lubricating Oil Service System › Piping
Issued 3 August 2016 Resolved
Repair lube oil leak in way of starboard lube oil regulator valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2016
Resolved 23 November 2016
Lifesaving › Launching Appliances › Falls
Issued 3 August 2016 Resolved
Canduct 1.1 weight test of rescue boat/davit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2016
Electrical › Electric Generation Source (service) › Generator
Issued 4 May 2016 Resolved
Generator windings have been damaged due to a piece of metal getting caught up in the windings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2016
Resolved 4 May 2016
Resolution: Ships force replaced generator end.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 April 2016 Resolved
AVH02: life jacket access in handicap passenger area is not accessible. Make access more accessible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 23 November 2016
Construction/Loadline › Structures › Superstructure
Issued 1 April 2016 Resolved
AVH01: Crack in frieght deck, provide report of final repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 19 April 2016
Resolution: Crack has been welded.

Casualty record · 17

30 January 2004Routine · role: Involved in a Marine Casualty · activity 2000300
27 January 2005Routine · role: Involved in a Marine Casualty · activity 2289125
14 March 2005Routine · role: Involved in a Marine Casualty · activity 2331318
28 January 2011Routine · role: Involved in a Marine Casualty · activity 3936357
1 September 2011Routine · role: Involved in a Marine Casualty · activity 4133625
25 November 2013Routine · role: Involved in a Marine Casualty · activity 4758971
22 May 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4870557
4 May 2016Routine · role: Involved in a Marine Casualty · activity 5878661
6 June 2016Routine · role: Involved in a Marine Casualty · activity 5909080
7 December 2016Routine · role: Involved in a Marine Casualty · activity 6113690
7 December 2016Routine · role: Involved in a Marine Casualty · activity 6113805
8 November 2017Routine · role: Involved in a Marine Casualty · activity 6327382
8 April 2019Routine · role: Involved in a Marine Casualty · activity 6658256
17 October 2021Routine · role: Involved in a Marine Casualty · activity 7334821
24 January 2022Routine · role: Involved in a Marine Casualty · activity 7385325
29 July 2024Routine · role: Involved in a Marine Casualty · activity 8027762
31 January 2025Routine · role: Involved in a Marine Casualty · activity 8078292
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.