Records from 2007 to 2026. Most recent: inspection, 8 July 2026.
Inspection history · 80
8 July 2026
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8433019
9 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8345335
10 March 2026
Vessel Attendance · MTSA Verification · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8320043
22 January 2026
Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8299531
4 December 2025
Damage Survey · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8277928
30 May 2025
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8148257
17 January 2025
COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8059352
10 December 2024
Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8045553
4 October 2024
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8014505
20 August 2024
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7985321
7 August 2024
Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7976304
29 July 2024
Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7969616
28 July 2024
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7974705
20 July 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7962576
12 June 2024
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7933536
4 March 2024
COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7871661
18 January 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7851306
8 January 2024
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7885260
7 November 2023
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7821514
1 November 2023
Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7818978
1 November 2023
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7821009
6 July 2023
Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7734457
21 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7672841
10 January 2023
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7615569
20 October 2022
Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7581482
15 September 2022
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7557245
28 July 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7519403
4 April 2022
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7427196
3 February 2022
COI Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7378595
10 January 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7377987
28 October 2021
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7382366
11 October 2021
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7330483
7 October 2021
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7328300
7 October 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7328681
26 August 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7361210
8 June 2021
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7215266
27 May 2021
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7212185
28 March 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7165566
26 March 2021
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7162899
16 March 2021
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7157276
21 January 2021
COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7128855
20 January 2021
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7130445
19 January 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7126523
18 December 2020
DAPI Audit · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7114782
3 December 2020
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7105922
19 November 2020
Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7104987
13 August 2020
Administrative Inspection · In-Service Inspection · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7031941
4 August 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7024447
10 March 2020
MTSA Verification · Examination of Repairs · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6894931
27 January 2020
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6896628
14 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6855818
16 October 2019
In-Service Inspection · DAPI Audit · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6832073
3 June 2019
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6709961
28 May 2019
MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6692588
24 January 2019
MTSA Verification · Deficiency Check · Administrative Inspection · COI Inspection · Examination of Repairs · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6615086
9 July 2018
MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6469112
8 June 2018
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6449434
5 June 2018
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6435590
13 April 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6391012
16 January 2018
COI Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam · In-Service Inspection · Deadweight Survey · Deficiency Check · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6338673
2 November 2017
In-Service Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6296388
23 October 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6294845
24 September 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6278055
9 September 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6291799
1 September 2017
DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6256976
10 July 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6261553
10 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139904
28 February 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6305870
21 February 2017
DAPI Audit · Deficiency Check · MTSA Verification · Plan Review (Other than "T") · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6089380
8 February 2017
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6085938
8 February 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6117398
2 February 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6081858
27 January 2017
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6078574
4 November 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6035351
7 September 2016
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5995159
21 August 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5984100
14 June 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5906894
9 June 2016
Periodic Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5922704
10 April 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5851283
22 March 2016
Damage Survey · DAPI Audit · MTSA Verification · Examination of Repairs · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5832990
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 March 2026
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Vessel did not complete a MOB and Fire Drill during their COI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2026
Resolved 7 April 2026
Resolution: Drills completed underway
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 March 2026
Resolved
Multiple lighting fixtures on the freight deck were inoperative, damaged, and missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2026
Resolved 20 March 2026
Resolution: See activity number 8320043
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 December 2024
Resolved
All automatic control, remote control, safety control, and alarm systems must be failsafe. Vessel throttle head is displaying a code that indicates that that the Woods Hole side of the ferry main propulsion is having an issue with the reduction gear. The cause of the fault alarm is undetermined. Make permanent repairs to the reduction gear/alarm system.46CFR62.31(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2024
Resolution: Witness repair and completed satisfactory operational test of the throttle system
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 August 2024
Resolved
Vessel had the #1 generator go off line due to a failure of the crank case sensor. #2 generator displayed a low hertz reading.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2024
Resolution: #1 crank case sensor replaced. Operationally tested all generators under load in parallel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 July 2024
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter. Crank case sensor wire harness clip on the #1 Generator prime mover is worn and loose, resulting in an improper connection between the wire harness and engine. The improver connection has and will result in the shut down of the #1 generator. Replace the harness/securing clip to the crank case sensor wire harness.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 November 2023
Resolved
If a main transverse watertight bulkhead is penetrated, the penetration must be made watertight. A thru bulkhead penetration in way of WTD #4 was improperly installed and not watertight. Provide watertight installation to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2023
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. The self-igniting light fitted on top side ring buoy was in-op. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 7 November 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 November 2023
Resolved
An MMC, license, MMD, COR, or STCW endorsement must be retained by the mariner to whom it was issued and, while valid, must be produced to verify qualifications when requested by an authorized official as identified in 33 CFR 101.515(d). The vessel Chief Engineer was unable to produce an MMC. Vessel was able to locate a properly credentialed Chief Engineer to take over operations over crew change-out.
Action required: 10 - Deficiency Rectified
Resolved 7 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2023
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the
vessel from electrical hazards. Loose control junction
box in way of WTD #1. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 7 November 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 November 2023
Resolved
Each vessel certificated under sub chapter H. must have an amplifier type announcing system that will supplement the general alarm system. Vessel master reported smoke from the public address system in the electrical control room. The PA system has been electrically isolated and tagged out. Affect repairs to the satisfaction of the Coast Guard Marine Inspector.
Vessel authorized to continue operations with the following stipulations; No passengers are authorized on the freight deck or the 01 deck while transiting. All passengers shall be on the 02 deck with four crew members with radios, two of which must have bullhorns forward and aft on the 02 deck. Maximum number of passengers allowed is 350. A fire watch must be posted at the electrical control room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 2 November 2023
Resolution: Completed operational test
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 November 2023
Resolved
While trouble shooting the inoperable public address system it was noted that the installed fire alarm (46CFR76.01-5) and required general alarm (46CFR77.05-1) are no longer operating. Vessel shall complete permanent repairs prior to carrying passengers. Vessel is authorized a one time transit from Martha's Vineyard, MA to Woods Hole, MA with no passengers or cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2023
Resolution: Completed an operational test
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 July 2023
Resolved
Several sections of fire insulation on the car deck ceiling required to be re-taped and sealed. There are two sections of missing fire insulation around the newly installed AC piping in the air handler room. Make permanent repairs to structural fire protection insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2023
Resolved 28 August 2023
Resolution: Completed examination of repairs
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 July 2023
Resolved
Several A-60 doors in the ladder well had holes from previously installed automatic closure devices that have been removed. The required A-60 doors are no longer considered A-60 with the holes in them. Make permanent repairs to the holes in all A-60 doors.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 July 2023
Resolution: Received text from [name withheld] stating doors are repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2023
Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Vessel's PSTP does not include written procedure for testing SSDG reverse power relays.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 10 October 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 April 2022
Resolved
A survey, either general or partial, according to teh circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. STBD Beam has damage from pier piling. Repair prior credit credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2023
Resolved 28 February 2024
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2021
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Vessel reported that the #3 SSDG tripped off line, and the #2 SSDG came on line as designed and took the load. Determine cause and repair the the satisfaction of the Coast Guard Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2021
Resolved 26 October 2021
Resolution: Report received. Uploaded. See activity #7330483.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 October 2021
Resolved
The material, design, construction, workmanship, and arrangement of the main propulsion machinery must be at least equivilent to the stds. established by the ABS Steel Vessel Rules. Vessel's woods hold end shaft bearing coupling had 3/4 bolts looken and cause vibration. 46 CFR 58.05-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2021
Resolved 7 October 2021
Resolution: Attended vessel, tightened bolts and underwent satisfactory sea trial with no vibration.
11 - Life Saving Appliances › N/A - No Subsystem › Marine Evacuation System
Issued 27 May 2021
Resolved
Make permanent repairs to port side MES door. Vessel restricted to 50% capacity until repairs are made to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 28 May 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2021
Resolved
STBD MES door was damaged during departure. Door must be replaced In-kind.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2021
Resolved 26 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2021
Resolved
SSDG #2 VOLTAGE REGULATION AND PARALLEL OPS MUST MEET ABS STEEL VSL RULES 4-8-3/3.13.2, 3.13.3. SSDG 2 REACTIVE LOAD SHARE AND REVERSE POWER RELAY NOT OPERATING PROPERLY. LOCK OUT TAG OUT AT ALL TIMES UNDERWAY. SHORESIDE TESTING AUTH WHILE MOORED TO DOCK. SSDG 1 AND 3, SUITABLE FOR SVC.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2021
Resolved 5 March 2021
Resolution: repaired gen #2, demonstrated parallel ops with 1 and 3.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 22 January 2021
Resolved
Rescue boat davit does not meet the gravity lowering speed requirements as required by 46 CFR 199.153. Prove proper operation of rescue boat davits and provide measurement from davit to waterline.
Action required: 705 - Other - as specified
Due 21 February 2021
Resolved 24 February 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 January 2021
Resolved
Repair the following fire doors that do not close and latch properly. 02-35W-1, 2-18M-2, 2-25W-2, 2-35M-1
Action required: 705 - Other - as specified
Due 21 February 2021
Resolved 9 February 2021
Resolution: Fire doors properly closed/latched
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2021
Resolved
Provide signs for type and proper numbers of lifejackets for stowage locations as discussed.
Action required: 705 - Other - as specified
Due 21 February 2021
Resolved 9 February 2021
Resolution: Signs posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2021
Resolved
Vessel reported inoperable #1 steering pump on bow steering gear (used on Woods Hole to Vineyard route). Vessel is required to effect reapirs & prove satisfactory operation to USCG prior to departure from Wood's Hole.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2021
Resolved 19 January 2021
Resolution: Vessel found tripped breaker for #1 steering pump. Witnessed satisfactory operation of pump, found sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 August 2020
Resolved
Prove proper operation of the #1 WTD to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 August 2020
Resolved 18 August 2020
Resolution: Ships forced repaired the WTD. Tested several times in the attendance of CGMI
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2019
Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 3 June 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2019
Resolved 3 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 May 2019
Resolved
Vessel's #2 rescue boat davit limit switch is not properly working. This is the switch located on the main crank. Repair or replace within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2019
Resolved 28 May 2019
Resolution: Vessel replaced limit switch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2019
Resolved
Provide evidence on what employees are considered HazMat Employees, who has completed HazMat training IAW 49CFR176.13 and 172.704, and provide records of such training.
Action required: 705 - Other - as specified
Due 15 June 2019
Resolved 26 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2019
Resolved
Prove proper operation of MV end bow thruster compartment bilge suction.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 February 2019
Resolved
Repair lights that are out in MV end steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 February 2019
Resolved
Prove proper operation of rudder angle indicators in both steering compartments. Indicators are hanging up and require pounding on gages to get needles to move.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 February 2019
Resolved
Label flashing red strobe lights to indicate purpose. ie, discharge of fixed fire extinguishing system for the bow thruster engine compartments.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 January 2019
Resolved
Repair exhaust leak on #3 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 January 2019
Resolved
Prove proper operation of the ground detection system ammeter on the main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 January 2019
Resolved
Prove proper operation of the high lube oil temp alarm on the #1 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2019
Electrical › Lighting (emergency) › Outlet Box
Issued 5 June 2018
Resolved
Vessel's Woods Hole end exterior MES evacuation light on port side does not work. Vessel is lock out and tag out breaker for daylight operations until repaired.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 5 June 2018
Resolution: Vessel was able to repair the light fixture and junction box.
Electrical › Lighting (service) › Outlet Box
Issued 5 June 2018
Resolved
Vessel is to inspect all exterior weather deck evacuation lighting plugs and J-boxes for functionality.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2018
Resolved 6 June 2018
Resolution: Vessel inspected J-boxes located on weather deck areas and replaced as necessary.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 5 April 2018
Resolved
Provide plan approval for submitted A/C one line, load analysis, and coordination study.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 30 May 2018
Communications › Alarms/Indicators › Lateral Thrust Propeller Indicator
Issued 5 April 2018
Resolved
Remove/disconnect not used R/G bow thruster sum alarm and bow thruster ctrl alarm from EMS Marcon panel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 26 February 2019
Operations/Management › Drills/Instruction › Fire
Issued 5 April 2018
Resolved
Conduct fire, man overboard, and security drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 13 April 2018
Resolution: Witnessed satisfactory drills.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 March 2017
Resolved
Conduct man overboard, fire, and security drills to the satisfaction of the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 10 May 2017
Resolution: Satisfactory drills were conducted.
Electrical › Electric Generation Source (service) › Generator
Issued 29 March 2017
Resolved
Lockout one generator in accordance with Steamship Authority's proposal dtd 28Mar2017 until approval of short circuit calculations is obtained from the Marine Safety Center or obtain plan approval and implement permanent modifications so that only 2 generators can be paralleled at any given time. Permission must be obtained from the OCMI to remove lockout on generator. See uploaded 835.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 May 2018
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 21 February 2017
Resolved
Steering system alarms for the Woods Hole end steering system do not sound in the pilot houses. (power failure, phase failure, low oil level)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 21 February 2017
Resolved
#3 SSDG low oil pressure shutdown/alarm not functioning. Repair and retest.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 21 February 2017
Resolved
Calibrate rudder angle indicators in steering compartments and pilothouses. (indicators off by up to 7 degress)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Construction/Loadline › Structures › Door
Issued 21 February 2017
Resolved
Repair #2 sliding water tight door. Hydraulic leak from fill/vent cap when attempting to close using manual hand pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 30 March 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 February 2017
Resolved
AVH01:Engineering department shall asses the bilge high level alarm in the Vineyard Haven bow thruster space. Due to the water reaching a height over the affected area it is recommended that the bilge high level alarm be lowered. Engineering shall evaluate the area and make effective repairs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: The bilge alarms are aproximently 1 foot above the bilge, a suffiecient height. During this casualty the height of the water above the bilge alarms was in excess of 8 feet above the alarms.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 8 February 2017
Resolved
Engineering departments policy on conducting rounds of unmanned spaces should be reviewed ensuring these spaces are being checked often within SSA written policy. In addition, it is recommended upper management look into these rounds as well to make certain each department is doing its due diligence of checking spaces. After review has been made contact CG Inspector with corrective actions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 27 March 2017
Resolution: Uploaded vessels standing orders regarding rounds for flooding.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 8 February 2017
Resolved
AVH03:Remove all excess water from Vineyard Haven bow thruster room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 February 2017
Engineering › Thrusters › Tunnel
Issued 8 February 2017
Resolved
AVH04: Provide a repair proposal that will include a plan to eliminate dissimilar metals for the shaft tunnel and salt water cooling line. In addition, due to this being a re-occurring issue the engineering department shall provide this plan in a timely manner.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 28 February 2017
Resolution: SSA is looking into a better design
Operations/Management › Pollution › Retention of Oily Mixture
Issued 27 January 2017
Resolved
Oil was found in the vessel's bilge areas in way of the main engines in the main engine room. Vessel is to remove oily water within the bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 21 February 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 January 2017
Resolved
Vessel's lifebuoys need to be restenciled with vessel's name and hailing port. Check all lifesaving for proper labeling.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 23 March 2017
Fire Fighting › Fire Hydrants › Number
Issued 27 January 2017
Resolved
Vessel's fire station was not properly labeled with station number. Ensure all stations are properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 23 March 2017
Deck/Cargo › Mooring/Anchoring › Winch
Issued 7 September 2016
Resolved
Vessel's forward starboard side anchor cannot be recovered if anchor is released. Recovery motor does not operate as designed. Repair or replace to CG satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 9 September 2016
Resolution: Witnessed satisfactory operation of the vessel's anchor windless; all sat.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 11 April 2016
Resolved
Revise PSTPs DTD Feb 2016 to reflect actual test procedures utilized by the vessel and re-submit to MSC for review.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 4 November 2016
Operations/Management › Drills/Instruction › Fire
Issued 11 April 2016
Resolved
Conduct fire, man overboard, and security drills to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 6 June 2016
Resolution: Drills have been completed
Electrical › Electric Generation Source (service) › Conductor
Issued 11 April 2016
Resolved
Lockout/Tagout on SSDG from being tied into the switchboard until MSC approves short circuit calculations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 27 April 2018
Resolution: Cleared. This is a duplicate deficiency of 29Mar17.
Electrical › Electric Generation Source (service) › Conductor
Issued 11 April 2016
Resolved
Provide MSC approval of drawings C through J refenced in MSC ltr E2-1500707 dtd 24Feb15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 21 February 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 April 2016
Resolved
Dry chem extinguisher was used for the emergency generator fire on this date. Replace in kind or recharge prior to operations. Location adjacent to e-gen space hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2016
Resolved 11 April 2016
Electrical › Electric Generation Source (emergency) › Conductor
Issued 10 April 2016
Resolved
Batteries, (x2 6D), wire, starter failed during manual mode starting causeing fire to the associated system. No other damage sighted in the vicinity or to the space. Prior to operations replace inkind.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2016
Resolved 11 April 2016
Engineering › Steering Gear System › Power Unit
Issued 6 April 2016
Resolved
M/V pilothouse has no control of steering system on the M/V end.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2016
Resolved 11 April 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 April 2016
Resolved
Mark with "E" on emergency light fixture fwd center in the E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2016
Resolved 11 April 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 April 2016
Resolved
Replace bulbs on emergency lights in the following locations. 1) Fwd Center E/R 2)Over W/H bow thruster controller 3) Top of ladder in crew quarters 4)ECR
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2016
Resolved 11 April 2016
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 29 March 2016
Resolved
Prove proper operation of overspeed device on #3 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2016
Resolved 6 April 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 March 2016
Resolved
Prove proper operation of time delay for the emergency generator space. Time delay failed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2016
Resolved 6 April 2016
Fire Fighting › Fire Pumps › Pumpshaft
Issued 22 March 2016
Resolved
Prove proper operation of the fire pump.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 22 March 2016
Resolved
Adjust the following doors FSD 01-30W-01 and 2-25W-2 and doors 02 level port forward and 03 levelstbd aft.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016
Fire Fighting › Structural - A Class Divisions › Windows
Issued 22 March 2016
Resolved
Properly replace 5 saftey glass windows (03 level port fwd (All 3 windows), 03 level stbd aft fwd window and the 02 level stbd aft side, forward window.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 23 March 2017
Navigation › Piloting/Steering › Marine Charts
Issued 22 March 2016
Resolved
Repair the Chart plotter M/V end
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016
Lifesaving › Rescue Boat › Markings
Issued 22 March 2016
Resolved
Renew reflective tape on forward rescue boat
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 22 March 2016
Resolved
Perform maintenance on anchor/windlass and retest
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 11 April 2016