MAURY USCG vessel records
← All vessels

MARTHA'S VINEYARD

Built
1993
Last inspected
21 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2026
…with no type recorded19
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9103881
WCC9025
395385
Flag
UNITED STATES
Maury page id
psix-395385

Documentation record

Registered dimensions (L × B × D)216.5 ft × 60.0 ft × 17.0 ft
Registered tonnagegross 1,449 / net 1,004
ITC dimensions (L × B × D)216.5 ft × 60.0 ft × 17.0 ft
ITC tonnagegross 2,795 / net 1,215
BuilderATLANTIC MARINE INC · JACKSONVILLE, FL, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWOODS HOLE, MA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1449 - Regulatory (Subpart C or D), Gross Ton
2795 - Convention (Subpart B), Gross Ton
1004 - Regulatory (Subpart C or D), Net Ton
1215 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 101 inspections, each with its date, unit and type; 67 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOVERNOR Passenger (Inspected) · MISLE 42928 · 6 July 2016 · activity 5940514

Inspection history · 101

21 May 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8377763
1 May 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8359405
9 April 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8345114
4 March 2026 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8318556
23 December 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8286667
26 November 2025 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8275554
23 October 2025 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8257875
23 September 2025 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8248737
11 July 2025 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8183197
16 June 2025 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8204791
3 April 2025 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8104458
2 March 2025 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087159
4 February 2025 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8074497
9 January 2025 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8060591
7 January 2025 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8059489
10 September 2024 Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7989477
4 June 2024 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7907370
24 March 2024 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7884235
27 February 2024 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7871050
31 January 2024 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7858991
2 January 2024 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7877657
26 October 2023 COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7800623
19 September 2023 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7790027
6 September 2023 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7786357
11 August 2023 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7764933
10 August 2023 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7765655
8 August 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7841317
15 July 2023 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7743053
8 May 2023 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7683729
5 April 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7663534
27 March 2023 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7657749
5 February 2023 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7632581
4 February 2023 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7632454
4 February 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7648205
2 February 2023 Re-Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7631604
30 January 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7628885
15 January 2023 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7626598
16 September 2022 COI Inspection · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7547768
5 February 2022 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7392410
19 December 2021 Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7370564
19 December 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7379529
9 November 2021 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7323883
20 September 2021 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7316512
28 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7212350
21 May 2021 Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7202846
29 March 2021 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7164891
13 March 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7155561
13 March 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7162838
24 February 2021 In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7144770
18 December 2020 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7114725
3 December 2020 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7106172
20 October 2020 MTSA Verification · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7054883
27 February 2020 Periodic Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6918953
16 December 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6879510
15 December 2019 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6874417
12 December 2019 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6872412
12 December 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6875386
11 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6872551
4 November 2019 Examination of Repairs · DAPI Audit · MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6845659
19 September 2019 Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6795863
13 August 2019 MTSA Verification · Periodic Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6777757
5 June 2019 Plan Review (Other than "T")
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6705546
20 May 2019 Administrative Inspection · DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6686454
21 March 2019 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6646792
6 February 2019 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6625099
1 February 2019 Administrative Inspection · MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6620136
11 January 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6609881
4 December 2018 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6591679
4 December 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6592768
27 November 2018 Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6588312
25 October 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6575974
10 September 2018 DAPI Audit · Deficiency Check · MTSA Verification · Examination of Repairs · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6535141
13 August 2018 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6510962
18 July 2018 Administrative Inspection · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6477663
7 July 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637897
13 June 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6452234
5 May 2018 Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6408492
5 May 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7173862
19 April 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6402969
5 April 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6381828
29 March 2018 Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6381186
18 March 2018 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6374633
15 August 2017 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6241639
7 August 2017 Administrative Inspection · Construction Oversight
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6241018
13 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6207667
28 June 2017 Cargo Tank Internal · Annual Inspection · COI Inspection · Construction Oversight · Deficiency Check · Examination of Repairs · Inclining Experiment · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6189814
16 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6153389
10 May 2017 In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139927
7 February 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6084151
18 January 2017 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6072894
28 November 2016 DAPI Audit · Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6043590
3 November 2016 Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6034617
14 October 2016 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6022553
10 August 2016 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5969791
21 July 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5957076
6 July 2016 Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5932051
6 July 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5940514
24 May 2016 Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5893692
20 May 2016 Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5874695
6 May 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878834
2 February 2016 Periodic Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5808267

Deficiency record · 67

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2026 No resolution recorded
Double doors capable of independent operation and latching may have a clearance between the doors not to exceed 1/8 inch. Double doors on the first deck exceed the 1/8' allowance in the door gap between doors. Make proper adjustments/ door replacement as needed. 46CFR72.05-25(7)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2026 Resolved
Pipe, tubing, pipe joining fittings, and piping system components, must meet material and standard requirements of subpart 56.60 and must meet the certification requirements of part 50 of this subchapter. The fuel pressure indicators on the port and starboard main engines were leaking fuel at the connection. Pressure indicators were removed and will be replaced.46CFR56.10-1(a)
Action required: 10 - Deficiency Rectified
Resolved 4 March 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 October 2025 Resolved
Alarm panel machinery monitoring is malfunctioning. Prove proper operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 September 2024 Resolved
Repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall not be made without the knowledge of the Officer in Charge, Marine Inspection. Crop and renew wasted deck/MSD tank top in galley to good metal to the satisfaction of the attending USCG Marine Inspector prior to next credit drydock.
Action required: 705 - Other - as specified
Due 16 September 2024
Resolved 7 October 2025
Resolution: During OCT2025 drydock the wasted deck was removed and new metal installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 March 2024 Resolved
A reduction pipe flanged between the main fire pump and the fire main has a pin hole in the middle of the pipe. Make permanent repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2024
Resolution: Received a video of the new spool piece installed and the fire pump running.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 January 2024 Resolved
Watertight doors must have controls in accordance with ASTM F 1197. Local control for the watertight door to the bow thruster room is inoperable. Watertight door can not be closed with the local control. The door can be closed remotely from the bridge and with the had pump closing device. Repair local control to bow thruster watertight door.46CFR170.270(c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 March 2024
Resolution: Received video
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2023 Resolved
Each cable installation must meet IEEE 45–2002. Recently installed fire detection cables are not properly secured with metal supports throughout freight deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 16 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 October 2023 Resolved
Each inflatable lifesaving appliance must be serviced within 12 months of each subsequent servicing. Provide liferaft servicing certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2023 Resolved
Each electric power, control, and interlock circuit of an elevator must meet ASME A17.1. Provide elevator servicing certificate prior to placing the elevator into service.
Action required: 705 - Other - as specified
Resolved 16 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 August 2023 Resolved
There shall be at least two means of escape from all general areas accessible to the passengers or where the crew may ...Two designated emergency egress scuttles where in operable from the escape side. Aux machinery space and bow thruster compartment. Provide proof of operation and unhindered passage for all designated below main-deck emergency egress to the satisfaction of the attending Marine Inspector. 46 CFR 72.10-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2023
Resolved 24 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 July 2023 Resolved
Vessel is required to display navigation lights that meet the 72COLREGS Rule 22 with navigation lights that meet the requirements of 46CFR111.75-18. Vessel currently has inoperable port and starboard navigation lights due to an electrical problem. Diagnose and repair the electrical problem and make repairs to original specs as outlined in the approved MSC drawings. Vessel is restricted to night time and reduced visibility operations until all navigation lights are repaired/replaced.
Action required: 705 - Other - as specified
Resolved 18 July 2023
Resolution: Received photos of port and starboard lights operational (top and bottom filament) and photo of the electrical panel that was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 March 2023 Resolved
Exhaust pipe installations must conform to the requirements of ABYC P–1 and part 1, section 23 of NFPA 302. The stbd MDE exhaust piping is leaking. Make repairs to the exhaust piping prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 March 2023 Resolved
The design, construction, and arrangement of main propulsion machinery directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. The stbd MDE shaft seal is leaking. Make permenant repairs to the shaft seal to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2023
Resolution: New seal was installed by Simplex, sea trial sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2023 Resolved
A survey, either general or partial shall be made every time a defect is discovered which affects the safety of the vessel. Vessel reported a switchboard problem and the # 3 SSDG would not parallel. #1 and #2 SSDG are paralleled in manual. Vessel is authorized a one time transit from vineyard haven to woods hole where the vessel will come out of service to determine the cause of switchboard issue and repair to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 January 2023
Resolved 30 January 2023
Resolution: See Activity Number 7628885
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 October 2022 Resolved
In the event of alterations involving the safety of a vessel, the applicable plans shall be submitted for approval covering the proposed work. Fire safety plan needs to be updated/corrected to satisfaction of CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 16 November 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 October 2022 Resolved
Where fire detecting systems and equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of 46 CFR Part 76. Submit as built dwgs for the fixed fire detection system to the USCG Marine Safety Center for review and approval prior to 20Nov2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 17 November 2022
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 February 2022 Resolved
Vessel's stern door is inoperable. Repair door to the satisfaction of USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2022
Resolved 24 February 2022
Resolution: Door properly repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2021 Resolved
The relief valve requirements for hot water heating boilers must be as indicated in article 4 of section IV of the ASME Boiler and Pressure Vessel Code. The relief valve on the #1 boiler does not meet the min relief capacity for the boiler. Tag out/lock out boiler and replace relief valve with one of sufficient capacity prior to placing boiler into service.
Action required: 705 - Other - as specified
Due 18 November 2021
Resolved 10 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2021 Resolved
A Survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Vessel reported the stbd shaft seal is leaking excessively. Repair of replace the stbd shaft seal to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2021
Resolved 29 March 2021
Resolution: STBD Shaft Seal Replaced to the satisfaction of the CGMI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2020 Resolved
Stbd low lube oil level is disabled due to the being inaccurate. Repair or replace sensor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2020
Resolved 3 March 2020
Resolution: Sensor replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
F/o service tank level indicator is faulty. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2020
Resolved 3 March 2020
Resolution: Sensor replaced.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 27 February 2020 Resolved
Escape hatch is leaking. Repair or replace gasket, Chaulk test hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2020
Resolved 23 March 2020
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2020 Resolved
Port and Stbd MDe exhaust is leaking. repair or replace exhaust.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2020
Resolved 23 March 2020
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 December 2019 Resolved
Loss of electrical power. Make repairs and test to the satisfaction of the attending USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 December 2019
Resolved 16 December 2019
Resolution: E-stop button malfunction in pilothouse, repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 December 2019 Resolved
Power-operated main and auxiliary steering gear must be independent. The #2 steering pump is inoperable. Repair/replace and conduct sea trials prior to carrying passengers to the satisfaction of attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 December 2019
Resolution: Power supply replaced, sea trials completed. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 November 2019 Resolved
The vessel owner/operator must obtain an approved NTVRP Approval Letter by 14 Dec 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 27 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2019 Resolved
Make permenant repairs to exhaust leaks in muffler void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 21 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 August 2019 Resolved
Repair doors 02-P-12, Main-S-60, and 02-S-24. These doors are not closinh properly. Have missing doors closure, a device blocking the door to close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 21 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 August 2019 Resolved
HPU in Aux room is leaking hydraulic fluid from the hose. Replace hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2019
Resolved 21 August 2019
Resolution: Hose has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2019 Resolved
Both MDE exhaust is leaking. repair or replace exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 21 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019 Resolved
Steering gear valve alignment. SSA shall install steering gear diagram and valve guide.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 February 2019
Resolved 6 February 2019
Resolution: Chief Engineer installed proper guides.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 December 2018 Resolved
Repair stern weathertight door to the satisfaction of the attending Marine Inspector. Stern door may remain open for the day (04Dec2018) as long as weather conditions do not change or worsen.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 December 2018
Resolved 4 December 2018
Resolution: Vessel repaired stern door.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 10 September 2018 Resolved
2 general alrm bells did not operate.
Action required: 10 - Deficiency Rectified
Due 17 September 2018
Resolved 17 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 September 2018 Resolved
Replace the reflective material on several child and adult life preservers.
Action required: 10 - Deficiency Rectified
Due 17 September 2018
Resolved 17 September 2018
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 June 2018 Resolved
3 fire doors are either malfunctioning or do not close properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 20 June 2018
Resolution: Ships force repaired the doors mentioned in the 835's.
Electrical › Electric Generation Source (service) › Generator
Issued 5 May 2018 Resolved
Tech report to clear faults on genset, complnent is still under warranty. Possible temp sending unit failure in gen set bearing housing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 May 2018
Resolved 7 May 2018
Resolution: Tech reported bad sensor and clear fault codes.
Construction/Loadline › Structures › Door
Issued 19 April 2018 Resolved
Vessels forward loading door is inoperable, due to failure of welds on the roller housing unit, which attached to the door track. Housing unit was replaced in kind along with one roller. Vessel is required to implement safety zone, with net 14 ft from center of loading door during operation until permanent repairs have been conducted and doors have been operationally tested to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 30 April 2018
Resolution: Operationally tested door three times, all sat.
Engineering › Steering Gear System › Pump
Issued 29 March 2018 Resolved
Breaker on the main bus OOC.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: New Breaker Installed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 March 2018 Resolved
SWITCHBOARD AUTOMATION NOT OPERATING PROPERLY, SHUT GENERATOR DOWN ERROUNEOUSLY.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 20 March 2018
Resolved 27 March 2018
Resolution: REPLACED COMPONENTS, I/O MODULES(PHEONIX) FOR EASY GEN
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 March 2018 Resolved
NON-CONDUCTIVE MATTS MATS MISSING IN FRONT OF ALL SWITCHBOARDS
Due 23 March 2018
Resolved 27 March 2018
Resolution: ADDED MATTS
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 18 March 2018 Resolved
OUTLET BOX NOT SECURED, FREE SWINGING ON CABLE IN ECR.
Due 23 March 2018
Resolved 27 March 2018
Resolution: SECURED OUTLET PROPERLY FASTENED TO BULKHEAD.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 18 March 2018 Resolved
BRIGE PORT SHAFT TACH NOT OPERATIONAL.
Due 23 March 2018
Resolved 27 March 2018
Resolution: REPAIRED PICKUP
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 18 March 2018 Resolved
FUEL OIL SERVCIE PUMP NOT OPERATIONAL, PUMP EMERGENCY SHUTDOWN DISCONNECTED. PUMP TAGGED OUT DUE TO EARLIER EVENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2018
Resolved 18 March 2018
Resolution: INSTALLED NEW RELAY, REWIRED E-SHUTDOWN CIRCUIT TO MAKE OPERATIONAL. PUMP TESTED ON E POWER, NORMAL POWER AND TESTED E-SHUTDOWN.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 18 March 2018 Resolved
AMP METER NOT OPERATIONAL
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 27 March 2018
Resolution: REPAIRED AMP METER
Personnel › Training › Familiarization Training
Issued 18 March 2018 Resolved
NOT ALL ENGINEERS ON WATCH ARE FAMILIAR WITH NEW EASY GEN SYSTEM ON THIS VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2018
Resolved 27 March 2018
Resolution: CHECK OFF SHEET CREATED BY C/E AND PORT ENG. SENIOR [name withheld] ALONG WITH EACH C/E FOR BEGINING OF EACH WATCH NEXT 5 DAYS UNTIL FAMILIARZATION SHEET IS COMPLETED.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 March 2018 Resolved
Obtain approved electrical plans from USCG MSC. Address all remaing coments from MSC ltrs E2-1800650, E2-1800640, dtd 01 Mar 2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 13 August 2018
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 7 March 2018 Resolved
Upon completion of MSC approvals of DVTP/PSTPs combine all DVTP/PSTPs in one document with consolidated table of contents. Submit to OCMI for approval.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 13 August 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 March 2018 Resolved
Conduct underway fire, man overboard, security and abandon ship drills.
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 5 April 2018
Resolution: Witnessed satisfactory man over drill, fire drill, and security drill.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 March 2018 Resolved
Provide indicators for the automatic ventilation louvers concealed in the 4 vents on the exterior of the 02 deck.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 15 March 2018
Resolution: Access doors provided in vent covers to allow the crew to open and see the automatice vent indicators.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 March 2018 Resolved
Provide appropriate ventilation closures in the two vents in the A-60 bulkhead between the starboard side elevator machinery space and the stateroom.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 17 September 2018
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 15 August 2017 Resolved
Noted vessel firefighter outfits oxygen bottles did not have adequate breathing air in them. Re-charge bottles for the suits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 25 August 2017
Resolution: New bottles were placed on board.
Fire Fighting › Grease Extraction Hood › General
Issued 15 August 2017 Resolved
Clean crew galley exhaust hood and provide servicing report for the fixed fire fighting suppression system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 19 January 2018
Construction/Loadline › Structures › Door
Issued 15 August 2017 Resolved
Door to galley for the crew has a broker latch. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 25 August 2017
Resolution: Galley door has been repaired
Fire Fighting › Fire Hoses › Connections
Issued 15 August 2017 Resolved
Several fire stations were missing spanner wrenches. Vessel is to check all fire stations and ensure they have spanner wrenches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 25 August 2017
Resolution: Several fire stations now have the correct # of spanner wrenches.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 May 2017 Resolved
Vessel's engine room bilge has 8" to 12" of oil in the bilge as per the chief engineer. Also, oily waste tank is full. Vessel will need to remove oil from the bilge and empty the oil bilge water holding tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 16 May 2017
Resolution: Vessel provided evidence of draining their oily waste bridge along with removing the oil from their bilge.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 November 2016 Resolved
Conduct underway man overboard, fire and security drills.
Action required: 705 - Other - as specified
Due 28 January 2017
Resolved 31 December 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 November 2016 Resolved
Provide a copy of the fixed fire fighting and portable fire extinguisher certificates.
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 30 December 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 14 October 2016 Resolved
Port MDE Exhaust leak. repair or replace port exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 3 November 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 14 October 2016 Resolved
Air Quality in Engineroom is poor. Upon Inspecting the engineroom a strong odor of exhaust is present. Additionally, there is a large amount of soot build up on equipment. Air quality needs to be addressed for the safety of the crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 3 November 2016
Construction/Loadline › Hull › Hull Plating
Issued 6 July 2016 Resolved
Damage due to collision with vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 21 November 2017
Communications › Internal Communications System › Sound-powered Telephone
Issued 2 February 2016 Resolved
Sound power #14 OOC. Repair phone.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Phone connection was repaired.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 February 2016 Resolved
"E" light IWO FSD #4 OOC. Repair light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Light has been repaired.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 February 2016 Resolved
there are multiple combustible trash cans throughout the ship. Trash can should be non-combustible type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Vessel replaced all trash cans with non-combustible materials.
Fire Fighting › Fire Hoses › Material
Issued 2 February 2016 Resolved
Fire stations 17 & 8 are missing spanner wrenches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Vessel installed spanner wrenches.
Fire Fighting › Means of Escape › Doorways
Issued 2 February 2016 Resolved
BD-05 door closure broken.Repair door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Door closure has been repaired.
Fire Fighting › Fire Hoses › Location
Issued 2 February 2016 Resolved
Fire station #6 can not be opened. Coffee machine is blocking access.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Coffee machine has been moved to a different location. Fire hose can be accessed.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 February 2016 Resolved
FD 08 door does not close properly. Repair door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 23 February 2016
Resolution: Door has been repaired.

Ownership record