Records from 1983 to 2015. Most recent: inspection, 11 January 2015.
Inspection history · 46
11 January 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5054474
31 March 2004
Permit to Proceed
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2035157
10 July 2002
Security Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1644065
3 May 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1626377
13 March 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1493556
28 August 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1370345
28 August 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1487469
5 August 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 280818
22 February 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 669023
2 December 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 28564
23 November 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1151204
10 December 1992
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 826769
17 July 1992
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954471
23 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265616
23 December 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962521
23 December 1991
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269571
6 December 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253237
5 December 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254249
25 November 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253036
27 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937201
11 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906115
1 October 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 925817
24 September 1990
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1217401
18 May 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230127
23 April 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 336634
28 January 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 518978
1 September 1989
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1199274
7 June 1989
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1199830
8 September 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1350873
26 August 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346907
20 August 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1037263
24 May 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890875
14 January 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 533680
23 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017250
8 July 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019019
8 July 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019022
2 July 1987
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019215
16 December 1986
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1312048
27 August 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 990215
15 August 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295943
31 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001447
6 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287435
9 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983454
25 April 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 986001
16 June 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 977023
4 May 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278235
Construction/Loadline
Issued 28 August 2001
Resolved
COMPLETE ISE IWO LEAKAGE FROM SLOP TANKS TO #5 DB BALLAST TANKS AFTER CARGODISC, TANK CLEANING AND GAS FREEING. MAKE REPAIR PROPOSALS TO CLASS AND USCG FOR APPROVAL. USCG AND CLASS TO BE IN ATTENDANCE FOR REPAIR INSPECTIONS. TO BE COMPLETED PRIOR TO NEXT LOADING AND NLT 10SEP01.
Condition: Unknown
Due 10 September 2001
Resolved 18 February 2004
Engineering
Issued 23 March 1992
Resolved
PROVE PROPER OPERATION OF AUX BOILER FEED WATER SYSTEM ON AUTOMATIC OPERATOR.
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Engineering
Issued 23 March 1992
Resolved
REPAIR OR REPLACE AUDIBLE AND VISUAL ALARM PANEL FOR AUX BOILER. (BOILER MUST BE MANNED ALL THE TIME DURING ANY OPERATION)
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Engineering
Issued 5 December 1991
Resolved
COMPLETE SATISFACTORY PERMANENT REPAIR TO FUEL TANK STBD VGO BUNKER TANK _x001C_NO LATER THAN 31MAR92
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Engineering
Issued 5 December 1991
Resolved
VESSEL IS PROHIBITED FROM CARRYING FUEL OR SLOPS IN STBD VGO BUNKER TANK_x001C_ UNTIL PERMANENT REPAIRS ARE COMPLETED TO THE SATISFACTION OF AN ATTENDING_x001C_ CG MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Construction/Loadline
Issued 25 November 1991
Resolved
MAKE PERMANENT REPAIRS TO DECK, PORT SIDE DECK BEAM, AND AFT BULKHEAD _x001C_ CORNER BRACKET IN FORWARD ROPE LOCKER, WHERE TRIPPED. THESE ITEMS TO BE COMPLETED AT NEXT DRYDOCKING AND IN ANY CASE NOT LATER THAN 31MAR92.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Electrical
Issued 18 May 1990
Resolved
LOCATE AND REPAIR GROUND FAULT/DETECTION ON BARGE FWD LIGHTING CIRCUIT.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 18 May 1990
Resolved
PROVE PROPER OPERATION OF OPERATIONAL SAFETY DEVICES IAW 46 CFR 63 FOR BARGE BOILER PRIOR TO PLACING INTO SERVICE.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Unknown
Issued 18 May 1990
Resolved
REMOVE ALL HIGH PRESSURE CYLINDERS WITH A HYDORSTATIC TEST DATE GREATER THAN 5 YRS AS LISTED; OXYGEN 3/79 NITROGEN 6-81, ACETYLENE 11-82, A-12 REFREGERANT 2-84 & 12-78, A-22 REFREGERANT 9-28 & 4-82.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Electrical
Issued 18 May 1990
Resolved
PROVE AUTOMATIC START UP OF SHIP'S SERVICE GENERATORS IAW AUTOMATION PROCEDURES.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Construction/Loadline
Issued 18 May 1990
Resolved
PROVE SET PRESSURE ON INBOARD SAFETY VALVE ON THE TUG BOILER.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 18 May 1990
Resolved
PROVE PROPER OPERATION OF HIGH/LOW LUBE OIL SUMP LEVEL FOR MDE SUMPS AS PERAUTOMAITON TEST PROCEDURES.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Electrical
Issued 18 May 1990
Resolved
INSTALL PERMANENT WIRING FOR 2 LIGHTING FIXTURES ONE LOCATED IN EACH MDE SPACE UPPER LEVEL BULKHEAD.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Electrical
Issued 18 May 1990
Resolved
REMOVE ALL PLASTIC TIE WRAPS LOCATED ON WIRE WAYS IN BOTH STEERING GEAR ROOMS, MACHINERY SPACES AND IN THE ENGINE CONTROL CONSOLE ROOM. INSTALL METALLIC WRAPS.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Construction/Loadline
Issued 18 May 1990
Resolved
PROVER PROPER LIFTING OF RELIEF VALVE ON THE DC HEATER FOR THE BARGE BOILERPRIOR TO PLACING INTO SERVICE.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Deck/Cargo
Issued 18 May 1990
Resolved
PROVE PROPER OPERATION OF #1 PRIME MOVER FOR HYDRAULIC CARGO PUMP, OVERSPEED (NOT TESTED).
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Fire Fighting
Issued 26 August 1988
Resolved
SHOW PROPER INSTALLATION OF PULL CABLES TO CO2 PILOT BOTTLES FOR ACTIVATIONOF HALON SYSTEM FOR TUG.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Fire Fighting
Issued 26 August 1988
Resolved
PROVE THE ENGINEROOM VENTILATION IS SECURED PRIOR TO DISCHARGE OF HALON INTO THE SPACE.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Fire Fighting
Issued 26 August 1988
Resolved
PROVE THE DIESEL GENERATORS ARE SECURED PRIOR TO DISCHARGE OF HALON INTO THE SPACE.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988
Fire Fighting
Issued 26 August 1988
Resolved
PLACE WARNING SIGNS AT THE ENTRANCE TO THE ENGINEROOM THAT STATES THIS SPACE IS PROTECTED BY A HALON SYSTEM.
Condition: Unknown
Due 26 August 1988
Resolved 26 August 1988