Records from 1984 to 1997. Most recent: inspection, 17 November 1997.
Navigation
Issued 30 May 1995
Resolved
Make permanant repair to autopilot servo motor and prove proper operation of steering system.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Engineering
Issued 30 May 1995
Resolved
MAKE PROPER REPAIRS OR RENEW AS ORIGINAL - ALL MAIN BOILER EXHAUST SYSTEMS.IN ORDER TO STOP EXHAUST LEAKS ASSOCIATED WITH BOILER EXHAUST EXPANSION JOINTS. REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CGMARINE INSPECTOR/COGNIZANT OCMI.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 2 May 1995
Resolved
Number four lifeboat nameplate data plate incorrect. Plate indicates 150 person lifeboat vice actual 60 person lifeboat. Provide proper capacity plate and properly afix to boat.
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Lifesaving
Issued 2 May 1995
Resolved
Properly label oil pressyre guage and start controllever direction of operation for #4 motor lifeboat.
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Fire Fighting
Issued 2 May 1995
Resolved
Submit drawing and list of materials for newly installed pressure switch and CO2 piping installation for forward paint locker. Prove proper operation and conduct installation test of CO2 pressure switch/piping for paint forward locker fan unit.
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Lifesaving
Issued 18 April 1995
Resolved
Restore #2 lifeboat as original or remove boat from vessel. In accordance with 46CFR75.05-5.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Lifesaving
Issued 18 April 1995
Resolved
#4 lifeboat in disrepair. Properly secure throttle cable adrift on motor box. Renew broken starter control handle, and missing transmission selector handle. Provide operating instructions and properly label all controls and gauges. Afix proper manufacturers capacity plate for boat.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Fire Fighting
Issued 11 April 1995
Resolved
Provide copies of all fire fighting system service reports. Reports must include but are not limited to: Tests and inspections performed, weights full and as recorded, hydrostatic test dates, 6yr maintenance dates, S/N's of all cylinders, and location of extinguishers aboard the vessel.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Electrical
Issued 28 March 1995
Resolved
Theater emergency exit light out. Trouble shoot, repair, and prove proper operation of exit light.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 28 March 1995
Resolved
Main galley gaylord hood exhaust duct automatic fusible link fire damper not functioning as designed. Provide print, research operation, repair as original, and prove proper operation.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 28 March 1995
Resolved
#2 Hatch cover failed hose test. Repair/reseal and prove #2 hatch cover water tight.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 21 March 1995
Resolved
M5 Provide dogging wrenches for watertight doors at engine lockers 3 and 4.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 21 March 1995
Resolved
M3 Bosun store CO2 discharge pipe cut in anchor windlass room. Make permanent repair to discharge line.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 21 March 1995
Resolved
M6 Provide cover for electrical box located in # 3 engine locker.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 21 March 1995
Resolved
M7 Ladder penetration cover through overhead of #3 engine locker space obstructed. Clear access and prove proper operation.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Construction/Loadline
Issued 21 March 1995
Resolved
M9 Properly screen rose boxes for port and starboard #6 hold bilge suctions.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 21 March 1995
Resolved
M8 Hold #3 CO2 discharge pipe holed. Make permanent repair to holed pipe located in bicycle storage room._x001C_
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 21 March 1995
Resolved
M2 Shelf installation in CO2 control room blocking access to control valves. Remove shelf to provide unobstructed access to control valves.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 21 March 1995
Resolved
M10 Provide knob for Theater stage door latch assembly.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 21 March 1995
Resolved
M11 Cable penetration through bulkhead 75 not properly sealed. Properly pack bulkhead cable penetration with approved material.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 21 March 1995
Resolved
M12 Provide discharge outlet of an approved type for CO2 discharge pipe serving Bosuns Stores.
Condition: Unknown
Due 29 March 1995
Resolved 5 April 1995
Construction/Loadline
Issued 21 March 1995
Resolved
M4 Bow thruster bilge suction well accumulated with rust, and scale. Clean bilges and prove proper operation of bilge pump.
Condition: Unknown
Due 29 March 1995
Resolved 12 April 1995
Fire Fighting
Issued 21 March 1995
Resolved
M1 Paint locker exhaust fan not provided with automatic shut down for fan upon CO2 discharge. Provide automatic ventilation shut down for forward_x001C_ paint locker vent fan and prove proper operation.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Construction/Loadline
Issued 14 March 1995
Resolved
Rose box strainers missing and/or in disrepair. Adjacent deck areas wastedand holed. Provide strainers and repair damaged strainers and adjacent deck areas as required to bring into compliance with 46 CFR 56.50-50.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Electrical
Issued 14 March 1995
Resolved
Provide adequate lighting for Fire Zone 5 emergency equipment locker.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 14 March 1995
Resolved
Emergency escape exit door from theater latch/knob in disrepair. Renew latch door knob and prove proper operation of the door and latch system.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Lifesaving
Issued 14 March 1995
Resolved
#4 lifeboat bilge pump discharge hose in disrepair, hose crushed, tape repair. Renew discharge hose.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 14 March 1995
Resolved
Demonstrate by positive means that all fixed CO2 discharge piping is clear.Demonstration to be to the satisfaction of the Chief of the Inspection Department.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Electrical
Issued 14 March 1995
Resolved
Repair inoperative light fixture atop the #6 elevator.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 14 March 1995
Resolved
#6 elevator trunk holed. Make permanent repair to bring elevator into required A boundary requirements.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Construction/Loadline
Issued 14 March 1995
Resolved
Cargo holds 2,3,4,5 contain excessive amount of rust, scale, and debris. Scale, muck out and remove rust, scale, debris, etc. from holds.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
Provide light for bottom of elevator shaft 6.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
Properly dead end or remove electric wires hanging from bottom of #6 elevator car.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
Provide general cleaning of #6 elevator electrical fixtures and controls.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Fire Fighting
Issued 14 March 1995
Resolved
Cable penetration through aft bulkhead Tropicana Showplace holed. Properlypack cable penetration with approved material.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Construction/Loadline
Issued 14 March 1995
Resolved
Hole punched in forward bulkhead of emergency squad equipment locker 6 to WTD oil reservoir tank. Tank missing cap. Provide cover for tank access and restore cover to tank.
Condition: Unknown
Due 21 March 1995
Resolved 15 March 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
CO2 room supply and exhaust vent ducting blocked, screens clogged with dirtand debris. Clean vents and prove ventilation adequate for CO2 room.
Condition: Unknown
Due 21 March 1995
Resolved 5 April 1995
Lifesaving
Issued 14 March 1995
Resolved
Make permanent repair in lieu of temporary repair to bottom of #4 lifeboat.Repair to include renewal of rotted floor boards, wasted rivits and flooring.
Condition: Unknown
Due 30 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #1, remove the debris from the drain located at the bottom of the elevator shaft.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Clean accumulated dirt and debris from WTD storage locations at WTD's 18B,12B, and 16B.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace the local selector switch for WTD 8B.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair the oil leaks identified on the local hand closing device handle for WTD 13B.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Replace the missing drain screens and renew any deteriorated drain trays located in the crew galley.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Locate the source of water leaking under the tiles in the crew galley, andmake proper repairs. Lift tiles as needed to remove standing water. Replace tiles and properly seal as needed upon completion. 14MAR95)
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Electrical
Issued 7 March 1995
Resolved
Restore the emergency lighting to the escape trunk located near the thaw box in the refer flat area.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Repair or replace the MSD lift station and associated defective MSD pipinglocated in the space across from the fresh fruit locker in the refer flat area.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 March 1995
Resolved
Crop and renew the wasted decks located under the MSD lift station in the space across from the fresh fruit locker in the refer flat area. All repairs are to be completed to the satisfaction of the attending marine inspector and consistent with good marine practice.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Effect temporary repairs to the leaky sewage pipes in the MSD lift stationlocated across from the fresh fruit locker in the refer flat area until such time as permanent repairs can be completed.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Remove raw sewage from the deck located in the MSD lift station located across from the fresh fruit locker in the refer flat area.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair the hydraulic oil leaks identified on WTD's 20B, 11C, 9C, 1D, 12B, 16B, and 8B.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace missing port light covers.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 March 1995
Resolved
Properly train personnel in handling and use of frapping lines during lifeboat drills.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Clean all excess debris and remove fire hazards from hold 6.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Post talk back system operating instructions in each elevator car fitted with a talk back system.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Provide gaging reports for the decks located at the bottom of elevator shafts 3, 4, 5, 6, and 7.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Electrical
Issued 7 March 1995
Resolved
Relamp the emergency exit lights located in the theater.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Renew the wasted deck near drain lines located above WTD 5C to restore water tight integrity.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Remove and replace the defective MSD units and all defective MSD piping located in holds 2, 3, 4, 5, and 6. All repairs are to be completed to the satisfaction of the attending marine inspector and consistent with good marine practice.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Replace the bottom of the vertical ladder at the tank top level in #2 hold.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Remove improper bolted pipe flange pipe penetration through bulkhead arrangement located on the forward bulkhead, port side of the #2 hold and replace it with a proper welded through bulkhead pipe fitting.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 March 1995
Resolved
Submit gaging report for tank top of #7 hold.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Navigation
Issued 7 March 1995
Resolved
Repair the selector switch for the sound powered phone on the bow.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Add missing light and whistle to bow lookout PFD.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Crop and renew the wasted bottom sections of the I beams supporting the overhang on the port and starboard sides of the Beach Comber Lounge. All repairs are to be completed to the satisfaction of the attending marine inspector and consistent with good marine practice.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 March 1995
Resolved
Gouge out and properly weld the fracture located below the cabin windows across from lifeboat #5.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Replace the defective plumbing located in the crew galley under the sinks.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Remove and properly store dry stores blocking the strainer located atop the rose box in hold 5.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair as original or renew the air operated bilge suction valve for hold 7 located at the aft end of the shaft alley.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Properly secure the piping attached to the oil content meters located in the auxiliary machinery space.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Engineering
Issued 7 March 1995
Resolved
Provide documentation that speedaire valves installed on fuel oil lines for boilers are acceptable for use in fuel oil systems.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Remove flammables stored between boilers 1 and 2.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Engineering
Issued 7 March 1995
Resolved
(W/L item E07) Replace rudder packing.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Make permanent repairs to leaky drain pipes located above the main electrical switchboards in the forward engine room.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
(W/L item E19) Provide proper dog retaining devices for all WTD's as required by ASME.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Electrical
Issued 7 March 1995
Resolved
Properly label areas located behind the main switchboards.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly label all fire equipment lockers.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Properly secure fan room light fixtures located on the sports deck, and ensure all deck lights throughout the vessel are properly secured.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
(W/L item E05) Gage the deck in the fan room located forward of the EMD generator room and renew where wastage exceeds 25% of original thickness.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 March 1995
Resolved
Properly seal bulkhead cable penetrations located in the radio battery room.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Engineering
Issued 7 March 1995
Resolved
Properly support free standing EMD generator fuel tank.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
(W/L item E01) Remove all damaged and defective batteries from the emergency battery room, and replace with like kind as original.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 March 1995
Resolved
Conduct a load test on both banks of emergency batteries in the presence of a marine inspector as required by 46CFR 78.17-45(c).
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Place an emergency eye wash station in the vicinity of the emergency battery room
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Documentation
Issued 7 March 1995
Resolved
(W/L item E18) Update and post all plans as required by 46 CFR 78.45-1.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Engineering
Issued 7 March 1995
Resolved
(W/L item E13) Identify the source of flue gas leaks noted in the forward engine room and make proper repairs as needed.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Engineering
Issued 7 March 1995
Resolved
(W/L item E06) Demonstrate proper operation of the fuel oil fill valve for the #1 port forward settler tank.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Electrical
Issued 7 March 1995
Resolved
Properly seal deck cable penetrations in EMD generator room.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Replace missing hand rails located at the upper level of hold 7.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Make permanent repairs in lieu of soft patches on the MSD system located in hold 6.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 March 1995
Resolved
Prove proper operation of the bilge suction system for holds 2, 3, 4, 5, 6, and 7
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Clean all dirt and debris from all rose boxes located in holds 2, 3, 4, and 5.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #4, secure from further use until all electrical fire hazards are properly addressed. Install proper wiring to control circuits and remove dangling cables from within the elevator shaft.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Prove proper operation of both bilge pumps and both bilge/ballast pumps atrated design capacity.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 7 March 1995
Resolved
Provide Certificates of Registry for a [name withheld], 1st assistant purser,and junior assistant purser.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly stow all equipment in emergency gear lockers.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Navigation
Issued 7 March 1995
Resolved
Provide proper side screen arrangements for the stern light.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Repair and prove satisfactory operation of FSD 37.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Documentation
Issued 7 March 1995
Resolved
Update, post and provide for review during inspections an accurate lifesaving plan.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Electrical
Issued 7 March 1995
Resolved
Properly secure wasted and fractured electrical junction box at #3 Lifeboat station ladder.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #2, replace the missing receptacle outlet cover.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Electrical
Issued 7 March 1995
Resolved
Restore adequate lighting to all levels of all cargo holds and prove proper operation.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #3, remove the dead ended cables located on the bottom of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #5, replace the missing junction box cover located on the top of the elvator car.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #5, replace missing covers for the electrical terminal boards located on top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Make elevator #6 available for inspection.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Properly label all PFD stowage lockers and locations.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #3, repair the elevator stop button located inside the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #5, replace the missing cover for the electric relays located on top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #3, repair the emergency lighting circuits.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #3, replace the missing terminal box cover located on the bottom of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Replace missing hardware and demonstrate closing of all vent closures on vent duct trunks located on focsle.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
(W/L item 121) Conduct annual servicing of all fixed CO2 systems and semi portable extinguishers in the presence of a CG Marine Inspector.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace wasted and fractured 1 1/2 inch vent pipe, port side of focsle, six foot forward of house.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Free up seized dogs on water tight door to deck house forward of #2 hold, focsle.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly secure heat detector in Tropicana Showplace, port aft service locker.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Clean excess dust from port side second row of heat detectors, Tropicana Showplace.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Permanently repair leaking piping over electrical equipment in starboard stewards pantry, Tropicana Showplace.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #7, replace the missing junction box cover located on the top of the elvator car.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #7, replace the missing junction box cover located on the bottom of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #4, cover all exposed electrical terminal boxes and junction boxes located on the top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #4, cover all the electrical relay circuits located on top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #4, remove all dead ended electrical cables located on top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Establish a program to familiarize Kauai, Maui, and Ohau fire departments with shipboard firefighting procedures.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Crop and renew the wasted and holded deck located at the bottom of the #5 elevators shaft. All repairs are to be completed to the satisfaction of the attending marine inspector and consistent with good marine practice.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 7 March 1995
Resolved
Renew wasted door hinges on door to elevator #1 machinery space, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Provide dead front cover for power panel P03-108-P, NWDG locker, starboardBoat deck.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Provide dead front cover for power panel P03-108-S, port NWDG locker, Boatdeck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew wasted areas of #5 Lifeboat davit assemblies.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Field day all crew quarters, remove excess combustibles and fire hazards, and any unauthorized modifications.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew wasted areas of #7 Lifeboat davit assemblies.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Crop and renew holed and wasted vent duct, forward NWDG locker, starboard Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
In lieu of soft patch, crop and renew pipe in trunk space at #2 Lifeboat, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Update fire control plans to reflect current equipment installation; submit for approval and post legible copy.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Properly label PFD stowage in passenger cabins.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Clean clogged vent screen for fire damper #47.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Electrical
Issued 7 March 1995
Resolved
Properly secure light switch, aft starboard air intake room, Sports deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly secure overhead heat detector in hospital.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Electrical
Issued 7 March 1995
Resolved
Properly label "Emergency" lighting in hospital.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly secure overhead heat detector in infirmary.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove complete closure and latching of fire screen door #12 and remove hold back device, Promenade deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
All weak links on liferafts missing name tag; renew all 15 weak links for the liferafts.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Send #1 Liferaft to approved facility for annual servicing, two months overdue.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Quarterly firing of line throwing gun elapsed, conduct training and fire line throwing gun.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Properly connect painter to weak link, #7 Liferaft.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew expired hydrostatic devices (Hammar) on #11 and #15 liferafts.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew grab line on life ring buoy, port and aft, #10 Lifeboat, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew grab line on life ring buoy, starboard, aft, under #11 Lifeboat, Promenade deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew grab line on life ring buoy, port forward breakwater, Upper deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew gasket on waterlight lens cover, port aft conning bridge, Upper deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
(W/L item 107) Renew kinked falls on #5 Lifeboat davit assembly; Determine and remedy cause of wire rope failure.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 March 1995
Resolved
Renew grab line life ring buoy, starboard capstan fan tail, Main deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew grab line life ring buoy, port capstan fan tail, Main deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
(W/L item 108) Renew kinked falls on #7 Lifeboat davit assembly; Determine and remedy cause of wire rope failure.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 March 1995
Resolved
(W/L item 109) Renew kinked falls on #9 Lifeboat davit assembly; Determine and remedy cause of wire rope failure.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 March 1995
Resolved
(W/L item 110) Renew kinked falls on #11 Lifeboat davit assembly; Determineand remedy cause of wire rope failure.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 March 1995
Resolved
Insufficient number of line throwing apparatuses aboard, provide three additional apparatuses, or provide sufficient number of rockets and cartridges for the Kilgore gun.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #1, replace the missing junction box cover located on the top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #1, replace the missing glass globe for the electric light located on the top of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #2, remove oil and dirt build up on electric cables located onthe bottom of the elevator car.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Crop and renew all wasted bottom sections of frames and bottom brackets tieing the vertical side frames to the tank top levels in holds 2, 3, and 4. All repairs are to be completed to the satisfaction of the attending marine inspector and consistent with good marine practice.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 March 1995
Resolved
Crop and renew the wasted decks located at the "D" deck level in holds 2, 3, and 4. All repairs are to be completed to the satisfaction of the attending marine inspector and consistent with good marine practice.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #1 provide a cover for the electric eye control box located on the bottom of the elevator car.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Electrical
Issued 7 March 1995
Resolved
Provide circuit directory for distribution panel in Solarium fan room.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Provide suitable suction strainer for the installed bilge pump, #4 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
On elevator #3, repair the alarm.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Relamp all extinguished lights located in the emergency escape tunnels.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair the selector switch indicator for WTD 18B.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Repair defective switches located on the refer boxes and replace missing lens covers.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace missing labels for WTD's and ensure all labels are ledgible and ingood condition.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace missing dogging wrenchs for the WTD's.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Provide proper selector switch for WTD 8B.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Permanently repair leaking piping over electrical equipment in starboard stewards pantry, Tropicana Showplace.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Engineering
Issued 7 March 1995
Resolved
(W/L item E20) Label and identify all Fuel and Flammable tank vents.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Remove obstructions blocking access to Fire station 57.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly arrange equipment in the fire locker located on Bali deck and ensure all equipment lockers are in good order.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove proper operation of fire main gauge on bridge.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew wasted foundation for searchlight.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Demonstrate proper operation of the smoke detection system in the presenceof a CG Marine Inspector.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly mount and prove operation of heat detector in chief mate's clothing locker.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace the missing alarm warning signs located near WTD's 11C, 7C, 8C, 18B, 8B, #2 hold, and #3 hold.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Remove portable extension cords located throughout the main galley.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew all fractured lifeline floats, #6 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Prove proper operation of talk back devices at the Lifeboat embarkation stations.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew deteriorated power supply cable to #2 Lifeboat embarkation light.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Free up corroded nozzle tip at fire station #14.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
In lieu of the two 6"x6" doubler plates on #2 Lifeboat, crop and renew to a minimum of 18"x18" bottom shell plating, garboard strake, amidships, port and starboard sides.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Properly secure adrift hydraulic hoses and valves, #4 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Provide proof that the six year maintenance requirement is current for allthe stored pressure dry chemical portable fire extinguishers.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Clean to white metal all bottom shell hull plating seams and butts for thorough examination, #6 Lifeboat; make permanent repairs as directed by the attending CG Marine Inspector.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew bottom shell plating in way of spigot patch, port side, garboard strake, three feet aft of stem, #6 Lifeboat.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 March 1995
Resolved
Renew fractured athwartships aft seat benches, #6 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew missing and broken hardware for the port and starboard aft bench seats, bottom row, #6 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Remove and properly stow excess gear from infirmary bath tub.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Remove from vessel wood canoe in purser area.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Electrical
Issued 7 March 1995
Resolved
Remove temporary overhead lighting in officer's lounge.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Electrical
Issued 7 March 1995
Resolved
Properly route and secure coaxial cable to the television in officer's lounge.
Condition: Unknown
Due 25 April 1995
Resolved 25 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Crop and renew wasted vent louvers and screens in all fan rooms exposed tothe weather decks.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Unplug and prove operation of clogged deck drain in Solarium fan room.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Properly label "Emergency" lighting in infirmary.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Unplug and prove operation of clogged deck drain in forward port air intake room.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Clean clogged vent screen at #11 fire damper.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Remove plastic bag installed in #5A fan room vent duct and renew duct as original.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly secure #46 fire damper access panel (held by tape) located in theTropicana Showplace.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
The #2 Lifeboat is not designed as a motor Lifeboat; remove outboard motorand gas tank and provide sails and sail equipment.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Provide protective guard for exposed water pump shaft in fan room #3C.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Replace all missing hardware for access panel at fire damper #43.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Replace missing vent screen to #6 fire damper.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Documentation
Issued 7 March 1995
Resolved
Correct and provide copies of all documents and certificates to reflect the correct owner and operator.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Provide one water fog applicatot for each of the (7) fire zone equipmentlockers.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Provide for each boiler room (1) portable foam applicator, (1) 20 litre canister of foam, and (1) spare canister of foam.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Provide three additional flame safety lamps or O2 meters for the repair lockers.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Renew the wasted drain lines above WTD 5C.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Provide each member of the fire patrol with a two-way portable radio telephone apparatus and demonstrate proper operation throughout the ship.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 7 March 1995
Resolved
(W/L item 114) Remove temporary wiring to bow light, properly install approved wiring and prove operation of the bow light.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Properly blank off the emergency exit from passing through the shower on the starboard side of the main deck forward of the pursers lobby and labelcrew side of the escape door as alternate emergency escape.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair the hydraulic oil leaks on hydraulic units for WTD's 4B, 5C and 9B.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair the alarm for WTD 7B.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Prove remote operation of WTD 7B.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Repair the local selector switch for WTD 5B.
Condition: Unknown
Due 25 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Prove watertight integrity of the watertight hatches on the Upper deck, focsle by chalk testing or hose testing.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Replace missing sounding tube plugs for chain locker and forepeak; sounding tube located in anchor windlass space.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove operation of fire alarm bell on "A" deck forward engineer berthing port side passageway.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Reinstall and prove proper operation of heat detector in Tropicana Showplace service locker.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove proper operation of heat detectors in Zone 31 on Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Prove watertight integrity of #1 and #2 cargo hold hatch covers by chalk testing or hose testing.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove proper operation of Manual fire alarm pull stations in Zone 31 on Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Prove watertight integrity of the port and starboard side ports by chalk testing or hose testing.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly label all fire zone lockers.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Repair emergency lighting at forward paint and oil locker, aft of bosn stores.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Replace missing globe on forward center overhead light, bosn stores.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Remove PVC pipe from exhaust line, #3 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Renew wasted dry chemical fire extinguisher at fire station #24.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Renew wasted and holed vent duct trunks, six port and six starboard, and provide suitable vent closures, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew missing lens cover gasket, #4 Lifeboat embarkation light.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew wasted bracket in area of aft limit switch, #2 Lifeboat davit assembly.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew wasted brackets and gussets, #4 Lifeboat aft davit.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Crop and renew wasted brackets and gussets on forward and aft davit assembly, #6 Lifeboat.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 7 March 1995
Resolved
Renew broken valve handle on wash down valve at fire station #13.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Free up corroded nozzle tip at fire station #8.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Reinstall 27 screws missing from engine cover, #4 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Provide adequate length upper pintle pin, #4 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Permanently repair as original, upper gudgeon, #4 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Provide suitable suction strainers for the two newly installed bilge pumps, amidships, starboard and forward port sides, #6 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew fuel in diesel storage tank in #4 Lifeboat.(CLEARED 14MAR95)
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Install valve handle and prove operation of the chain locker eductor.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Conduct annual servicing on 15lb CO2 fire extinguisher, #18, entrance to butcher shop.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Remove lock and cable assembly; permanently repair door frame and latch mechanism; outboard meat freeze box.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Properly label "man locked in reefer/freezer" alarms in all boxes; five each on "C" deck and six each on "D" deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Prove operation of the searchlight.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Install and prove operation of the second smoke detection sniffer motor and blower assembly.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Replace missing door latch in door to forward Engine room uptake space, starboard passageway, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Navigation
Issued 7 March 1995
Resolved
Label port and starboard radar transponders with vessel name.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Label 406 EPIRB and Class "A" EPIRB with vessel name.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Renew expired battery in Class "A" EPIRB.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Navigation
Issued 7 March 1995
Resolved
Renew missing and rotten wood planking on flying bridge helm station.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Renew wasted and fractured foundation for deck light above #8 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Navigation
Issued 7 March 1995
Resolved
Properly secure electrical cables with metallic straps every 24", port bridge wing from RPM indicators to #1 fire station.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Navigation
Issued 7 March 1995
Resolved
Prove operation of the port and starboard bridge wing RPM indicators.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 7 March 1995
Resolved
Crop and renew wasted decking aft port air intake room, Sport deck.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 March 1995
Resolved
Renew broken and missing overhead light fixtures in aft port air intake room, Sport deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Renew broken overhead light fixture in paint locker, Sport deck. Provide an approved type.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Prove operation of defective general alarm bells #21 and #119.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Remove independent flotation tanks on #2 Lifeboat for examination of the floatation tanks and Lifeboat internals.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Prove hydraulic starting system can maintain pressure for a 24 hour period, and demonstrate six start capacity of the hydraulic starting system, #4 Lifeboat.
Condition: Unknown
Due 25 April 1995
Resolved 18 April 1995
Electrical
Issued 7 March 1995
Resolved
Replace missing eye wash station at forward paint and oil locker, aft of bosn stores.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Deck/Cargo
Issued 7 March 1995
Resolved
Permanently repair oil leaks on both anchor windlass'; remove drip bucketsand clean excess oil from equipment and deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
(W/L item 123) Demonstrate proper operation of the automatic sprinkler system in the presence of a CG Marine Inspector.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Electrical
Issued 7 March 1995
Resolved
Properly secure power cable to evaporator unit #57, bread and juice reeferbox.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Properly secure all heat detectors in flour storage locker.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove proper operation of the bridge ventilation shutdown; provide and post an index listing all vent blowers associated with this shutdown.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Replace broken circuit breakers on switchboard in anchor windlass space.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Demonstrate proper operation of the gaylord hood system in the automatic mode, main galley, and crew's galley.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Make available for examination, all gaylord hood exhaust vent ducts in themain galley and crews galley.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Prove proper operation of seized inner door latch, vegetable walk-in reefer, main galley.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Remove temporary wiring, permanently install approved wiring to reefer box#22, dinner salads, main galley.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
(W/L item 125) Remove fire alarm pull box from gaylord hood system, replacewith proper switch, main galley, and crew's galley.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
(W/L item 126) Demonstrate proper closure of fire screen door #22A, main galley.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Prove proper operation of seized inner door latch, larder walk-in reefer,Main galley.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
25APR95 dead front cover for exposed power panel L2-147-P, main galley.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Renew broken CO2 horn and conduct annual servicing on 15lb CO2 fire extinguisher, #C17, crews galley.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Prove complete closure of fire screen doors #6, Promenade Deck, Constitution lounge.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Prove operation of all deck lighting on the Sport deck.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Reinstall latch devices, prove proper operation and complete closure of fire screen doors #5, Promenade deck, Constitution lounge.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Install lens covers on all naked lights in crew quarters.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Lifesaving
Issued 7 March 1995
Resolved
Update lifesaving plans to reflect current equipment installation; submit for approval and post legible copy.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Renew/repair as original, main galley fire screen doors and automatic doors.
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Fire Fighting
Issued 7 March 1995
Resolved
Replace missing fire extinguisher #32 in Radio Room.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Repair overhead lighting in trunk space of #2 Lifeboat, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Properly secure deck grating in #2 trunk space, forward of #2 Lifeboat, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Repair overhead lighting in NWDG locker, starboard Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Electrical
Issued 7 March 1995
Resolved
Renew broken light switch, NWDG locker forward, starboard Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 7 March 1995
Resolved
Permanently repair fractured blower foundation in #2 trunk space, forward of #2 Lifeboat, Boat deck.
Condition: Unknown
Due 25 April 1995
Resolved 13 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Renew as original, weather doors to stairwells on Promenade deck port and starboard aft area.
Condition: Unknown
Due 25 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 7 March 1995
Resolved
Permanently seal opening cut into #5 elevator shaft trunk bulkhead, and reinsulate this area, Sport Deck.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Electrical
Issued 7 March 1995
Resolved
Properly secure fractured deck light mounting brackets over #11 Lifeboat, and over #11 Liferaft.
Condition: Unknown
Due 25 April 1995
Resolved 5 April 1995
Engineering
Issued 30 December 1994
Resolved
REPAIR LEAKY FUEL OIL HEATER LINE AT THE UNION IN WAY OF FUEL OIL HEATERS.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 30 December 1994
Resolved
REPAIR THE GAP OR HOLE BETWEEN THE SUPERHEATER HEADERS TO PREVENT GAS LEAK INTO THE AIR BOX.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Accommodation/Occupational Safety
Issued 30 December 1994
Resolved
MAKE PERMANENT REPAIR TO THE SOFT-PATCHED FRESH WATER RECIRC LINE IN ER #2 UNDER DECK PLATE PORT OUTBOARD OF THE F/O SERVICE PUMP.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 30 December 1994
Resolved
REPAIR EXCESSIVE LEAK ON THE 600 LBS CROSS CONNECT STEAM VALVE LOCATED FWD OF BOILER NO.3.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 30 December 1994
Resolved
REPLACE DAMAGE GASKET AT THE LEAKY FLANGE IN THE DESUPERHEATED LINE BHD STOP FWD AND ABOVE NO.3 SSTG.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 30 December 1994
Resolved
CLEAN AND MAKE AVAILABLE FOR INSPECTION THE WATERSIDE OF NO.3 BOILER. DO NOT USE BOILER UNTIL AFTER SATISFACTORY INSPECTION.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 30 December 1994
Resolved
RENEW BROKEN MAIN STEAM PIPE SPRING HANGER LOCATED AFT AND ABOVE NO.4 BOILER.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 30 December 1994
Resolved
REPAIR FRACTURE IN THE NO.3 BOILER INNER CASING BEHIND THE FORWARD HANDHOLDON THE SIDEWALL HEADER._x001C_
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Accommodation/Occupational Safety
Issued 30 December 1994
Resolved
REPLACE OR RE-ROUTE THE 8 INCH PVC PIPING IN WAY OF STEAM PIPING ABOVE NO.4 BOILER.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Engineering
Issued 17 December 1994
Resolved
Make permanent in lieu of temporary repair (red hand patch) to the upper oil cooler forward main condensor spoolpiece, and to the auxiliary condensor overboard elbow in the aft engineroom._x001C_
Condition: Unknown
Due 17 December 1994
Resolved 17 December 1994
Electrical
Issued 7 December 1994
Resolved
Motor control centers and switchboard hinged doors in disrepair. Ronew/repair all electrical switchboards/motor control center door hold back devices. IAW 46CFR111.70-3. IAW 46CFR111.30.
Condition: Unknown
Due 20 December 1994
Resolved 4 January 1995
Electrical
Issued 7 December 1994
Resolved
Properly mark all emergency lights throughout the vessel. IAW 46CFR112.43-17.
Condition: Unknown
Due 20 December 1994
Resolved 12 January 1995
Lifesaving
Issued 7 December 1994
Resolved
Block and tackle secured to emergency generator fuel oil tank vent riser. Properly secure block and tackle.
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Lifesaving
Issued 7 December 1994
Resolved
Provide operating instructions and proper control labels for #2 motor lifeboat. IAW 160.35-5_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Fire Fighting
Issued 7 December 1994
Resolved
PROVIDE THE PROPER FIREMANS' OUTFIT GLOVES AS PER 46CFR77.35-5(f).
Condition: Unknown
Due 7 January 1995
Resolved 4 January 1995
Navigation
Issued 7 December 1994
Resolved
Trouble shoot repair and prove proper operation of aft deck steering wheel and compass light._x001C_ _x001C_
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Lifesaving
Issued 7 December 1994
Resolved
REMOVE AND REPLACE WITH AN APPROVED TYPE, THE GAS TANK IN LIFEBOAT NO.2.
Condition: Unknown
Due 7 January 1995
Resolved 4 January 1995
Lifesaving
Issued 7 December 1994
Resolved
RESTENCIL LIFEBOAT NUMBER ON LIFEBOAT NO.2._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1995
Resolved 4 January 1995
Accommodation/Occupational Safety
Issued 7 December 1994
Resolved
REMOVE ALL COMBUSTIBLE WASTE PAPER BASKETS AND REPLACE WITH INCOMBUSTIBLE WASTE BASKETS AS PER 46CFR72.05-55(b).
Condition: Unknown
Due 7 January 1995
Resolved 4 January 1995
Construction/Loadline
Issued 7 December 1994
Resolved
Provide copy of current hull gauging report to the [name withheld] for evalution._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 February 1995
Resolved 1 February 1995
Accommodation/Occupational Safety
Issued 7 December 1994
Resolved
Clean officers mess and galley to bring to a satisfactory sanitary condition. IAW 46CFR71.45
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Lifesaving
Issued 7 December 1994
Resolved
REPLACE OR REPAIR DRAIN ON NO.8 LIFEBOAT.
Condition: Unknown
Due 7 January 1995
Resolved 11 January 1995
Navigation
Issued 7 December 1994
Resolved
Provide legible and accurate operating instructions for changing the steering gear. IAW 46CFR78.47-55
Condition: Unknown
Due 20 December 1994
Resolved 4 January 1995
Lifesaving
Issued 7 December 1994
Resolved
PREPARE ALL LIFEJACKETS FOR INSPECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1995
Resolved 11 January 1995
Electrical
Issued 7 December 1994
Resolved
Properly dead end electrical cables, and properly secure electrical boxes not properly secured throughout the ship. IAW 46CFR111.75-20, 111.81-1.
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Engineering
Issued 7 December 1994
Resolved
Excessive lengths of fuel hose in use for fuel piping on main boiler burnersystem. Bring fuel system into compliance with 46CFR56.50-65_x001C_
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Fire Fighting
Issued 7 December 1994
Resolved
Properly mark all hand portable fire extinguishers with a number and the location where stored with a corresponding number at 1/2 inch high. IAW 46CFR78.47-30
Condition: Unknown
Due 20 December 1994
Resolved 4 January 1995
Fire Fighting
Issued 7 December 1994
Resolved
Repair leaking valve on the discharge side of number 3 fire pump. Valve overhaul to be completed prior to completion of next drydock exam. _x001C_ _x001C_
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 December 1994
Resolved
Laundry in general state of disrepair, maintenance and cleanliness. Properly secure all electrical cables, remove all extension cords, restore steam press safety devices, renew/repair door nobs, bring washer/dryers andother service equip. into compliance with UL standard, and clean laundry.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 7 December 1994
Resolved
Numerous sections of lagging disturbed on high temperature piping. Properly insulate all high temperature piping. IAW 46CFR 56.50-1
Condition: Unknown
Due 7 February 1995
Resolved 7 February 1995
Engineering
Issued 7 December 1994
Resolved
Make temporary repair to the wasted and holed spool piece upper oil cooler forward main condensor. Permanent repair/renewal to be completed prior to returning to service from shipyard.
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Lifesaving
Issued 7 December 1994
Resolved
Clean and properly secure items adrift in the capstan room.
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Lifesaving
Issued 7 December 1994
Resolved
REPAIR FLEMING GEAR BUSHING BRACKET IN LIFEBOAT NO. 8._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1995
Resolved 4 January 1995
Electrical
Issued 7 December 1994
Resolved
Properly secure expanded metal protective screen for emergency generator cooling fan._x001C_ _x001C_
Condition: Unknown
Due 20 December 1994
Resolved 19 December 1994
Fire Fighting
Issued 3 December 1994
Resolved
Doors leading from forward and after machinery spaces missing latches and/or knobs. Restore all doors throughout the vessel as original. IAW 46CFR72.05-25.
Condition: Unknown
Due 3 December 1994
Resolved 3 December 1994
Engineering
Issued 3 December 1994
Resolved
Boiler alley gauge boards in disrepair. Gauge glasses broken, water level indicators bent and mutilated, faces broken and torn, gauges not labeled and/or improperly labeled. Renew, repair, and/or recalibrate all damaged and malfunctioning gauges and indicators as required. IAW 46CFR71.10
Condition: Unknown
Due 3 December 1994
Resolved 3 December 1994
Lifesaving
Issued 13 October 1994
Resolved
#4 motor lifeboat in disrepair. Restore #4 motor lifeboat as original. Restoration to include: motor box, battery box, equipment locker, floor boards, hydraulic starter hose, Rottmer release, and operating instructions.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Construction/Loadline
Issued 13 October 1994
Resolved
Port and starboard sideports at "Time Square" in disrepair. Renew door gaskets and prove watertight.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Electrical
Issued 13 October 1994
Resolved
Speaker wire connection at lifeboat station #8 splice, not proper. Bring cable splice into compliance with 46CFR 111.60-13.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Electrical
Issued 13 October 1994
Resolved
Deck lights located on the front of the house foredeck area, in disrepair, fixtures fallen off and hanging by electric cable. Properly mount light fixtures in accordance with 46CFR 111.75-20.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Accommodation/Occupational Safety
Issued 13 October 1994
Resolved
Air supply vent located on boat deck near #8 lifeboat wasted and holed. Make permanent repair to restore as original.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Lifesaving
Issued 8 October 1994
Resolved
NUMBER THREE MOTOR LIFEBOAT ENGINE BOX IN DISREPAIR. COVER ADRIFT, COVER DAMAGED, HINGE BROKEN. MAKE PERMANENT REPAIR TO RESTORE ENGINE BOX AS ORIGINAL IN ACCORDANCE WITH 46CFR160.035-5.
Condition: Unknown
Due 8 October 1994
Resolved 8 October 1994
Lifesaving
Issued 8 October 1994
Resolved
ROTTMER RELEASE GEAR NOT PROPERLY TIMED. HOOK NOT PROPERLY POSITIONED AND DOES NOT TRAVEL THROUGH 180 DEGREE ARC. PROPERLY TIME ROTTMER RELEASE AND BRING INTO COMPLIANCE WITH MANUFACTURES SPECIFICATION.
Condition: Unknown
Due 8 October 1994
Resolved 8 October 1994
Electrical
Issued 8 October 1994
Resolved
Lifeboat embarkation lights in disrepair. Embarkation lights are frozen inmounts. Free up or renew light assemblies and prove proper operation in accordance with 46CFR75.50-10 and 46CFR111.75-16.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 24 September 1994
Resolved
REMOVE AND MAKE PROPER REPAIRS TO THE WATER BUBBLED DECK, APPROXIMATELY FOUR(04) SQUARE FEET, IN THE MAIN GALLEY LARDER STATION. PROVIDE GAUGING OFTHIS AREA TO THE ATTENDING CG MARINE INSPECTOR AND MAKE REPAIRS AS DEEMED NECESSARY BY THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 24 September 1994
Resolved
RESEAL OPEN GAPS BETWEEN DECK TO BULKHEAD THROUGHOUT ENTIRE MAIN GALLEY. OPEN GAPS IN THESE AREAS HAVE EXCESSIVE STANDING WATER AND NO MEANS FOR DRAINAGE.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 24 September 1994
Resolved
INSTALL DRAINS FOR THE FOLLOWING MAIN GALLEY AREAS: PANTRY LOCKER, STBD SIDE ELECTRICAL STATION, FORWARD BEVERAGE STATION, ICE MACHINE STBD DRAINWELL, POT & PAN ROOM AND THE PLASTIC WARES ROOM.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 24 September 1994
Resolved
INSTALL NEGATIVE MECHANICAL VENTILATION IN THE VEGETABLE ROOM IN THE MAIN GALLEY, AS ORIGINAL.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER FOUR LIFEBOAT DAVIT AFT AND FORWARD BRACKETS.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER ON LIFEBOAT DAVIT AFT AND FORWARD BRACKETS.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRTS TO NUMBER THREE LIFEBOAT DAVIT AFT BRACKET.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER EIGHT LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER TEN LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER ELEVEN LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER TWELVE LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 13 June 1994
Resolved
PROVE PROPER OPERATIONS OF WATER TIGHT DOORS #15B AND #07C.
Condition: Unknown
Due 12 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW ALL TWO POLE LIFEBOAT LIMIT SWITCHES WITH THREE POLE SWITCHES IAW 46 CFR 111.95-5(C). LIFEBOAT LIMIT SWITCHES WERE ORIGINALLY THREE POLE SWITCHES AND AN UNAUTHORIZED MODIFICATION WAS MADE RENEWING THE THREE POLE SWITCHES WITH TWO POLE SWITCHES.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER FIVE LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Documentation
Issued 13 June 1994
Resolved
PROVIDE MERCHANT MARINER DOCUMENTS FOR SANITATION OFFICER AND ENTERTAINMENTSTAFF._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1994
Resolved 7 July 1994
Lifesaving
Issued 13 June 1994
Resolved
PROVIDE WEATHERTIGHT STORAGE LOCKER FOR MESSENGER LINE AND FLAG LOCKER ON FLYING BRIDGE.
Condition: Unknown
Due 12 July 1994
Resolved 27 June 1994
Fire Fighting
Issued 13 June 1994
Resolved
REPAIR/REPLACE BROKEN AND LOOSE WIRE INSERTED GLASS IN DOOR LOCATED PORTSIDE FORWARD IN MAIN GALLEY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1994
Resolved 27 June 1994
Electrical
Issued 13 June 1994
Resolved
REPLACE/RENEW TWO(02) BATTERIES WITH WARPED LIDS LOCATED IN THE BATTERY ROOM.
Condition: Unknown
Due 12 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
SUBMIT PLANS FOR APPROVAL FOR BBQ "PIGROAST" ON FANTAIL.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Engineering
Issued 13 June 1994
Resolved
OPEN FOR FIRE AND WATERSIDE EXAMINATION, PERFORM HYDRO TEST AND PROVE PROPER OPERATION OF ALL SAFETY VALVES FOR #1 MAIN PROPULSION BOILER.
Condition: Unknown
Due 12 July 1994
Resolved 7 July 1994
Lifesaving
Issued 13 June 1994
Resolved
PROVE VESSEL CONDUCTING BOAT DRILLS WITH FULL COMPLIMENT OF PERSONS ON BOARD AT LEAST ONCE PER WEEK AS PER 46 CFR 78.17-50._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Fire Fighting
Issued 13 June 1994
Resolved
RENEW GLASS IN FIRE SCREEN DOOR #13 MAIN DECK WITH USCG APPROVED GLASS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1994
Resolved 27 June 1994
Lifesaving
Issued 13 June 1994
Resolved
SUBMIT FIRE LOAD ANALYSIS FOR NEWLY INSTALLED WOODEN LAWN CHAIRS AND _x001C_ DIRECTOR CHAIRS IN AND ADAJACENT TO THE "BEACHCOMBERS BAR" AND FOR THE _x001C_ WOODEN CANOE IN MAIN DECK FOYER.
Condition: Unknown
Due 12 July 1994
Resolved 7 July 1994
Fire Fighting
Issued 13 June 1994
Resolved
PROVIDE TWO (2) O2 INDICATORS FOR FIREMANS OUTFIT
Condition: Unknown
Due 12 July 1994
Resolved 27 June 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER FIVE LIFEBOAT DAVIT FORWARD LOCKING BAR AND FORWARD BRACKET.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER SIX LIFEBOAT DAVIT FORWARD AND AFT LOCKING BAR.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER SEVEN LIFEBOAT DAVIT FORWARD LOCKING BAR AND FORWARD AND AFT BRACKETS.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER EIGHT LIFEBOAT DAVIT FORWARD LOCKING BAR AND AFT LOCKING BAR.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER NINE LIFEBOAT DAVIT FORWARD BRACKET.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Navigation
Issued 13 June 1994
Resolved
RENEW PORT NAVIGATION LIGHT BULB WITH AN USCG APPROVED TYPE.
Condition: Unknown
Due 12 July 1994
Resolved 27 June 1994
Lifesaving
Issued 13 June 1994
Resolved
SUBMIT PROOF THAT THE NEWLY INSTALLED POPCORN, HOTDOG, ICE SHAVER AND COFFEE MACHINES ARE EITHER U.L. APPROVED OR MARINE TYPE.
Condition: Unknown
Due 12 July 1994
Resolved 7 July 1994
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER SEVEN LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 13 June 1994
Resolved
CROP AND RENEW APPROXIMATELY SIX(06) LINEAR FEET OF BUCKLED SIDE SHELL FRAME #104 LOCATED BEHIND THE 20 TON DISTILLED WATER TANK ON THE STBD SIDE UPPER LEVEL OF THE FORWARD MACHINERY SPACE. TO BE COMPLETED AT NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 June 1994
Resolved
PROVIDE "UL" APPROVED GLOBE GUARDS FOR CREW AND ACCOMONDATION SPACE LIGHTING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Lifesaving
Issued 13 June 1994
Resolved
CROP AND RENEW WASTED TRACKWAYS ON FORE AND AFT DAVITS AND REPLACE TRACKWAYWHEEL WITH FLAT SPOT ON #5 LIFEBOAT GRAVITY DAVITS.
Condition: Unknown
Due 12 July 1994
Resolved 27 June 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER TWELVE LIFEBOAT DAVIT FORWARD AND AFT LOCKINGBAR AND FORWARD AND AFT BRACKET.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER TWELVE AFT ELEVATOR BLOCK SWING ARM.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 June 1994
Resolved
MAKE PROPER REPAIRS TO NUMBER SIX FORWARD ELEVATOR BLOCK SWING ARM.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 13 June 1994
Resolved
PROVIDE GAUGING REPORT AND MAKE TEMPORARY REPAIRS TO WASTED AREAS ON THE UPPER LEVEL AFT BULKHEAD OF THE AFT MACH SPACE PORT SIDE. GAUGING TO BE ACCOMPLISHED ON 12" CENTERS VERTICALLY AND HORIZONTALLY IN AN 8' BAND MEASURED DOWN FROM THE OVERHEAD ACROSS THE ENTIRE WIDTH OF 2P & 3POB TANKS.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 June 1994
Resolved
CROP AND RENEW ALL WASTAGE BEYOND 25% LOCATED IN THE AFT UPPER LEVEL BULKHEAD IN THE AFT MACHINERY SPACE PORT SIDE, AS INDICATED ON GAUGING REPORT REQUIRED BY CG835 IDENT./ E3 ISSUED THIS CASE MI94021200. TO BE COMPLETED DURING THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 June 1994
Resolved
PROVIDE GAUGING REPORT OF ALL INTERNAL STRUCTURAL MEMBERS, BULKHEADS, DECKSAND TANKTOP OF THE AFT COFFERDAM.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 June 1994
Resolved
CROP AND RENEW ALL WASTAGE BEYOND 25% AS INDICATED IN GAUGING REPORT REQUIRED BY CG835 IDENT./ E6 ISSUED THIS CASE #MI94021200. TO BE COMPLETED AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 June 1994
Resolved
RENEW AS ORIGINAL GROOVED LIFEBOAT SHEAVES ON NUMBER SIX LIFEBOAT DAVIT.
Condition: Unknown
Due 13 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 30 April 1994
Resolved
CROP-OUT AND RENEW THE FOLLOWING DISTORTED FLOORS IN THE NO.2 STARBOARD DOUBLE BOTTOM TANK; FROM THE CENTER LONGITUDINAL WATERTIGHT BULKHEAD INBOARD SECTION: FRAMES 46, 47, 48, & 49 AND THE BUCKLED FLOOR ON FRAME 61.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 April 1994
Resolved
CROP-OUT AND RENEW THE FOLLOWING DISTORTED FLOORS IN THE NO.2 PORT DOUBLE BOTTOM TANK; FROM THE CENTER LONGITUDINAL WATERTIGHT BULKHEAD INBOARD SECTION: FRAMES 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, & 57 AND FROM THE SIDESHELL OUTBOARD SECTION: FRAMES 50, 51, 52, & 53.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 April 1994
Resolved
CROP-OUT AND RENEW WASTED KNEE BRACKETS IN THE HOLD NO.2 TANKTOP PORT AND STARBOARD SIDE FRAMES.
Condition: Unknown
Due 30 April 1994
Resolved 30 April 1994
Construction/Loadline
Issued 4 April 1994
Resolved
PROVIDE GAS FREE CERTIFICATE ISSUED BY AN NFPA CERTIFIED MARINE CHEMIST ANDMAKE AVAILABLE FOR INTERNAL INSPECTION THE FOLLOWING TANKS: NO.2 PDB, NO.2 SDB, NO.3 PDB AND NO.3 SDB.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 7 December 1993
Resolved
REPAIR OR RENEW LEAKING HYDRAULIC RAM ON WTD#1.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Lifesaving
Issued 7 December 1993
Resolved
PROPERLY REPAIR BRACKET FOR LIFERING #17.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Lifesaving
Issued 7 December 1993
Resolved
REPLACE BOLT IN LIFEBOAT #12 RELEASING GEAR SHAFT IN WAY OF LOWER, FORWARD U-JOINT.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
PROVIDE VENTILATION TO WASHER #1 ELECTRICAL CONTROL CABINET SUCH THAT WASHER IS OPERABLE WITH CABINET DOOR CLOSED.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Construction/Loadline
Issued 7 December 1993
Resolved
UNCLOG DECK DRAINS ON "BT" DECK BETWEEN LIFEBOATS #1 AND 3 AND BETWEEN LIFEBOATS #2 AND 4.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
REPAIR/RENEW FREEZER DOOR LOCKS FOR PANTRY AND OUTBOARD MEAT LOCKER.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Fire Fighting
Issued 7 December 1993
Resolved
REPAIR THE BINDING HOSE REEL LOCATED IN THE AFT MACHINERY SPACE.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Fire Fighting
Issued 7 December 1993
Resolved
REPAIR LEAKING VALVE AT FIRE STATION #110 LOCATED PORT SIDE AUX MACHINE SHOP.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Engineering
Issued 7 December 1993
Resolved
INSTALL MISSING INSULATION ON STEAMLINE LOCATED IN THE AFT MACHINERY SPACE FWD OF THE MAIN REDUCTION GEAR JUST INBOARD OF THE MAIN CONDENSER.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
MAKE TIGHT THE ACCESS PLATES TO THE FOLLOWING COLLECTION TANKS: 1. BOTH TANKS IN NO.6 HOLD, 2. TANK IN NO.4 HOLD, 3. TANK IN NO.2 HOLD.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Construction/Loadline
Issued 7 December 1993
Resolved
MAKE PORT AND STARBOARD DOORS TO THE EMERGENCY GENERATOR ROOM WEATHERTIGHT.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
REPAIR OVERHEAD SHEATHING AND RE-ATTACH LIGHT FIXTURE IN PORT LINEN LOCKER,"D" DECK, SHIPS LAUNDRY.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
REPAIR OVERHEAD SHEATHING IN SOILED LINEN LOCKER, FORWARD, OUTBOARD, "D" DECK, LAUNDRY.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Lifesaving
Issued 7 December 1993
Resolved
PROVIDE 92 LIFEJACKETS FOR INSPECTION BY A MARINE INSPECTOR. UNTIL SUCH TIME THE TOTAL NUMBER PERSONS CARRIED SHALL NOT EXCEED 1367 PERSONS.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Construction/Loadline
Issued 7 December 1993
Resolved
REMOVE "REDHAND" AND MAKE PERMANENT REPAIRS TO THE DRAIN PIPE LOCATED IN THE AFT MACHINERY SPACE BEHIND THE MAIN SWITCHBOARD, FORWARD.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Fire Fighting
Issued 7 December 1993
Resolved
MAKE OPERABLE KIDDE SMOKE DETECTION CABINET. UNTIL SYSTEM IS OPERABLE, HOURLY ROUNDS OF ALL CARGO HOLDS SHALL BE CONDUCTED AND LOGGED IN THE BRIDGE LOG.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 November 1993
Resolved
PROVIDE A COPY OF THE ELEVATOR SERVICING REPORT AND PROVIDE A COPY OF THE WRITTEN ESTIMATE OF DAMAGES RESULTING FROM THE FIRE IN THE CLEAN LINEN LOCKER TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 December 1993
Resolved 16 December 1993
Accommodation/Occupational Safety
Issued 7 November 1993
Resolved
RENEW FOUR DAMAGED FIRE DETECTORS IN THE CLEAN LINEN LOCKER AND DEMONSTRATEPROPER OPERATION OF THE FIRE DETECTION SYSTEM TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 11 December 1993
Resolved 16 December 1993
Accommodation/Occupational Safety
Issued 7 November 1993
Resolved
MAKE AVAILABLE FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR THE BULKHEAD OVERHEAD INSULATION IN THE CLEAN LINEN LOCKER.
Condition: Unknown
Due 13 November 1993
Resolved 6 December 1993
Accommodation/Occupational Safety
Issued 7 November 1993
Resolved
RENEW AS ORIGINAL ALL GLOBE LIGHT FIXTURES/BULKHEAD RECEPTACLES AND ASSOCIATED ARMOURED CABLE IN THE CLEAN LINEN LOCKER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 December 1993
Resolved 16 December 1993
Fire Fighting
Issued 23 October 1993
Resolved
PERFORM DAILY CLEANING OF EXCESSIVE GREASE AND LINT BUILT-UP OVERHEAD AND VENT SYTEM IN THE CREW GALLEY AS PER 46 CFR 71.25-40.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Engineering
Issued 16 October 1993
Resolved
REPLACE THE BROKEN SUPERHEATER TEMPERATURE GAUGE ON NO.3 MAIN BOILER GAUGE BOARD LOCATED IN THE AFT MACHINERY SPACE AS PER 46 CFR 71.30-5(a).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Lifesaving
Issued 16 October 1993
Resolved
RENEW THE WASTED BOTTOM MOUNTING BRACKET AND ASSOCIATED FASTENERS ON THE AFT RELEASING GEAR ON LIFEBOAT NO.9 AS PER 46 CFR 71.25-50. THE VESSEL'S TOTAL PASSENGER CAPACITY ON THE "COI" SHALL BE REDUCED BY 150 PERSONS UNTILALL REPAIRS ARE COMPLETED ON THIS REQUIREMENT AS PER 46 CFR 75.10-10(a).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Electrical
Issued 16 October 1993
Resolved
RENEW THE (3) DAMAGED EMERGENCY LEAD BATTERIES LOCATED IN BATTERY LOCKER AFT OF THE EMERGENCY GENERATOR ROOM AS PER 46 CFR 111.15-2.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGE STBD SIDE SHELL PLATE BETWEEN FR 68 & 69 AT "J" STRAKE DOWN INTO "K" STRAKE APPROX. 9'X10' AREA INCLUDING ALL ASSOCIATED FRAMES AND BRACKETS AS PER FIELD SURVEY SUBMITTED BY OCEAN SURVEYS AND MANAGEMENT COMPANY DATED 16OCT93 IAW 46 CFR 71.50-3(d).
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 16 October 1993
Resolved
REMOVE FLAMMABLES (FIRE HAZARDS) FROM STORAGE SHELVES IN THE AFTER LAZZERETTE AS PER 46 CFR 71.25-50.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Lifesaving
Issued 16 October 1993
Resolved
REPLACE THE WASTED FASTENERS ON FORWARD RELEASING GEAR COLLAR SUPPORT ON LIFEBOAT NO.11 AS PER 46 CFR 71.25-50.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
MAKE THE FOLLOWING WATERTIGHT DOORS IN COMPLIANCE WITH 46 CFR 71.25-25 AS FOLLOWS: WTD NO.10B ADJUST THE CLOSING SEQUENCE, WTD NO.20B MUST OPERATE MANUALLY, AND PERFORM MAINTENANCE ON THE SEALING SURFACES(PAINT) ON WTD'S NOS. 10B, 15B, AND 19B.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Electrical
Issued 16 October 1993
Resolved
REMOVE THE DEAD-END WIRE ON FWD PORT BULKHEAD AND INSTALL CORRECT COVERS ONALL EXPOSED 115 VAC LOW & HIGH PRESSURE CUT OUT SWITCHES IN THE "B" DECK REEFER SPACE AS PER 46 CFR 111.60-17.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Unknown
Issued 16 October 1993
Resolved
PROVIDE UPDATED DRAWINGS OF PIPING DIAGRAMS FOR MODIFICATIONS COMPLETED DURING LAST DRYDOCKING TO THE FUEL TRANSFER AND SLOP TANK SYSTEMS AS PER 46CFR 71.65-10.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
REPAIR TORN INSULATION IN THE FOLLOWING SPACES: (a)AFT MACHINERY SPACE BEHIND MAIN SWITCHBOARD FWD, (b) FWD MACHINERY SPACE OVERHEAD STBD AND (c)(12) AREAS OVERHEAD IN THE STEERING GEAR ROOM IAW 46 CFR 72.05-1.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Navigation
Issued 16 October 1993
Resolved
INSTALL COAST GUARD APPROVED NAVIGATIONAL LIGHTS FOR THE STERN AND ANCHOR LIGHTS AS PER 46 CFR 111.75-17(d).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Deck/Cargo
Issued 16 October 1993
Resolved
PERFORM ROUTINE MAINTENANCE (FREE-UP) ON ALL "PANAMA CHOCKS" AS PER 46 CFR 71.25-50.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Electrical
Issued 16 October 1993
Resolved
INSTALL HIGH STRENGTH GUARDS FOR EACH GLOBE LIGHTS IN THE FOLLOWING AREAS: "B" DECK 3RD STEWARDS OFFICE, LOCKER NEXT TO FIRESTATION NO.81, LOCKER BY HOSPITAL NEAR GURNEY, BARTENDER SECTION FWD ON "B" DECK, LOCKER BY PORT FUELING SIDEPORT AS PER 46 CFR 111.75-20.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Electrical
Issued 16 October 1993
Resolved
REPLACE THE MISSING ELECTRICAL PANEL COVER IN SERVICE LOCKER NO.15 LOCATED ADJACENT TO CABIN NO.54 AS PER 46 CFR 111.40-1.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Electrical
Issued 16 October 1993
Resolved
REPLACE THE BROKEN LIGHT GLOBE FIXTURE OUTSIDE OF CABIN NO.58 AS PER 46 CFR111.75-20.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Lifesaving
Issued 16 October 1993
Resolved
RENEW WASTED FLEMMING GEAR HANDLES NO.1, 5, AND 6 ON LIFEBOAT NO.7 AS PER 46 CFR 78.17-60.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
RE-INSTALL MISSING STEAM PIPE INSULATION ON NO.4 MAIN STEAM TURBINE GENERATOR AS PER 46 CFR 56.50-1(K).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
RE-INSTALL THE MISSING STEAM PIPE INSULATION LOCATED AFT & OUTBOARD OF THE PORT MAIN REDUCTION GEAR IN THE AFT MACHINERY SPACE AS PER 46 CFR 56.50- 1(k).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
REMOVE OR MAKE WATERTIGHT THE STUFFING TUBE LOCATED IN THE FORWARD BULKHEADCENTERLINE IN THE AFT ROPE STOWAGE SPACE AS PER 46 CFR 71.25-25(a)(1).
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
REPAIR THE TORN OVERHEAD INSULATION IN THE WAY OF THE UPPER MAIN CONTROL STATION IN THE AFT MACHINERY SPACE AS PER 46 CFR 72.05-1.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
CROP-OUT AND RENEW THE LOWER WASTED AREA OF THE STANCHION LOCATED IN THE AFT MACHINERY SPACE STBD IN A WAY OF NO.3 FIRE PUMP AS PER 46 CFR 71.15-1.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
MAKE THE STARBOARD BILGE PIPING SYTEM TO THE NO.2 CARGO HOLD AS PER 46 CFR 56.50-50.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
INSTALL A HEAT SENSOR IN THE SERVICE LOCKER LOCATED IN "ARNOLD'S LOUNGE" ASPER 46 CFR 76.05-1(a).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
MAKE DOOR LEADING TO AFT ENGINEROOM CLOSE PROPERLY, DOOR DOES NOT LATCH.
Condition: Unknown
Due 20 November 1993
Resolved 18 October 1993
Accommodation/Occupational Safety
Issued 16 October 1993
Resolved
MECHANICALLY CLEAN EXCESSIVE GREASE & LINT BUILD-UP IN THE VENT SYSTEM & INTHE OVERHEAD AREA (FIRE HAZARDS) AND INSTALL THE PROPER FUSIBLE LINKS ON FIRE DAMPNERS NO.151, 152, 153, 154, AND 155 IN THE CREWS GALLEY AS PER 46 CFR 71.25-40 & 71.25-45.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
REPLACE MISSING COUNTERWEIGHT FOR THE AUTOMATIC FIRE DAMPNER NO.119 ON THE "B" DECK AS PER 46 CFR 72.05-50.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
INSTALL HEAT SENSORS ON THE "A" DECK IN THE POOL PUMP ROOM AND ON THE "A" DECK NO.2 CARGO HOLD FORWARD AS PER 46 CFR 76.05-1(a).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Fire Fighting
Issued 16 October 1993
Resolved
REPLACE THE INSTALLED CLEAR PLEXI-GLASS ON ALL GALLEY DOORS WITH THE PROPERWIRE INSERTED GLASS IN THE MAIN GALLEY AS PER 46 CFR 72.05-25(b)(4)&(c)(2).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Accommodation/Occupational Safety
Issued 16 October 1993
Resolved
REMOVE THE POURED CONCRETE PLUG ON THE DECK DRAIN NEAR THE SCULLERY AREA AND MAKE PERMANENT REPAIRS TO THE WASTED DRAIN LINE IN THE MAIN GALLEY AS PER 46 CFR 71.25-40.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
REPLACE THE MISSING VENT COVER LOCATED STARBOARD SIDE IN WAY OF STARBOARD CAPSTAN ON THE FOC'SULE UPPERDECK AS PER 46 CFR 171.122(f)(2).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
PERFORM DAILY MAINTENANCE(FREE-UP) DOGGING DEVICES AND REPLACE GASKET TO VENT COVER ON THE UPPERDECK CENTERLINE AFT OF THE SWIMMING POOL AS PER 46 CFR 171.122(f)(2).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Construction/Loadline
Issued 16 October 1993
Resolved
PERFORM DAILY MAINTENANCE BY REPLACING (6) MISSING SECURING BOLTS, FREE-UP (2) SECURING BOLTS, AND REPLACE THE GASKET ON THE VENT COVER ON THE STARBOARD SIDE OF THE UPPERDECK IN WAY OF THE SWIMMING POOL AS PER 46 CFR 171.122(f)(2).
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Engineering
Issued 31 July 1993
Resolved
IDENTIFY AND LABEL THE GOOSENECK VENT LOCATED ON THE FOREDECK, PORTSIDE OUTBOARD KINGPOST AS PER 46 CFR 56.50-85(a)(8). VENT OUTLETS MUST BE IN ACCORDANCE WITH 46 CFR 56.50-85(a)(8).
Condition: Unknown
Due 31 July 1993
Resolved 31 July 1993
Deck/Cargo
Issued 10 July 1993
Resolved
AS PER 46 CFR 56.50-85(a)(7)(i), RENEW SEWAGE VENTLINE GOOSENECK BALL CHECKBODY ASSEMBLY ON FOCSULE PORT SIDE.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Accommodation/Occupational Safety
Issued 10 July 1993
Resolved
AS PER 46 CFR 71.45-1, REFASTEN LOOSE OVERHEAD PANELS LOCATED IN UPPERDECK PANTRY.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Navigation
Issued 10 July 1993
Resolved
AS PER 46 CFR 111.80-70, PROVE PROPER OPERATION OF HAND ELECTRIC STEERING SYSTEM.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Electrical
Issued 10 July 1993
Resolved
AS PER 46 CFR 112.50-1, REPAIR THE JACKET WATER LEAKS ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 10 July 1993
Resolved 10 July 1993
Accommodation/Occupational Safety
Issued 10 July 1993
Resolved
AS PER 46 CFR 72.20-90(d)(1) & (6), RENEW/REPAIR DRINKING FOUNTAIN LOCATED ON THE UPPER LEVEL OF THE AFT MACHINERY SPACE.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Electrical
Issued 10 July 1993
Resolved
INSTALL PROTECTIVE COVERINGS FOR THE LIGHT IN THE MACHINERY SPACES.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Engineering
Issued 10 July 1993
Resolved
AS PER 46 CFR 56.50-1(k), INSTALL INSULATION OVER EXPOSED AREAS ON NO. 4 AND 5 FEEDWATER PUMPS LOCATED IN THE AFT ENGINEROOM.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Construction/Loadline
Issued 10 July 1993
Resolved
AS PER 46 CFR 72.01-25, RENEW GASKETS ON BOTH MAIN DECK FANTAIL WATERTIGHT HATCHES.
Condition: Unknown
Due 10 July 1993
Resolved 10 July 1993
Construction/Loadline
Issued 10 July 1993
Resolved
AS PER 46 CFR 72.01-25, MAKE WATERTIGHT THE AFTMOST WATERTIGHT HATCH TRUNK ON FANTAIL MAIN DECK.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Construction/Loadline
Issued 10 July 1993
Resolved
AS PER 46 CFR 72.01-25, RENEW GASKET ON ESCAPE SCUTTLE, PORT MAIN DECK AFT.
Condition: Unknown
Due 10 July 1993
Resolved 10 July 1993
Lifesaving
Issued 10 July 1993
Resolved
AS PER 46 CFR 113.25-9, INSTALL GENERAL ALARM BELL IN VICINITY OF SERVICE PANTRY FORWARD OF GIFT SHOP ON UPPER DECK.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Construction/Loadline
Issued 10 July 1993
Resolved
AS PER 46 CFR 72.01-25, RENEW GASKET ON WATERTIGHT DOOR LOCATED ON FOCSULE LEADING TO #2 CARGO HATCH.
Condition: Unknown
Due 10 July 1993
Resolved 10 July 1993
Lifesaving
Issued 10 July 1993
Resolved
AS PER 46 CFR 75.10-5(a)(2), MAKE OPERABLE THE HAND PROPELLING GEAR ON LIFEBOATS NO. 5 AND 7.
Condition: Unknown
Due 10 July 1993
Resolved 10 July 1993
Deck/Cargo
Issued 10 July 1993
Resolved
AS PER 46 CFR 56.50-85(a)(8), RENEW 30X30" MESH FLAME SCREEN FOR NO. 5 AND 6 DEEPTANK GOOSENECK VENTS LOCATED ON AFT MAIN DECK.
Condition: Unknown
Due 10 July 1993
Resolved 10 July 1993
Lifesaving
Issued 10 July 1993
Resolved
AS PER 46 CFR 113.25-15(c)(2), PROPERLY ADJUST GENERAL ALARM BELL #321 TO AN ACCEPTABLE SOUND LEVEL, LOCATED UPPER DECK PORT SIDE JUST FORWARD OF GIFT SHOP.
Condition: Unknown
Due 31 July 1993
Resolved 2 August 1993
Construction/Loadline
Issued 26 June 1993
Resolved
IN ACCORDANCE WITH 33CFR 155.370, INSTALL THE OWS BILGE ALARM SYSTEM AS PERMANUFACTURE'S INSTRUCTIONS. DEMONSTRATE COMPLIANCE IN THE PRESENCE OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 26 June 1993
Resolved 26 June 1993
Construction/Loadline
Issued 26 June 1993
Resolved
RENEW DESSICATORS ON OWS BILGE ALARMS AS PER MANUFACTURE'S INSTRUCTIONS. DEMONSTRATE COMPLIANCE IN THE PRESENCE OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 26 June 1993
Resolved 26 June 1993
Construction/Loadline
Issued 26 June 1993
Resolved
IN ACCORDANCE WITH 33CFR 155.370, DEMONSTRATE PROPER OPERATION OF OWS BILGEALARM USING A CALIBRATED OIL-FREE SAMPLE AND A CALIBRATED 15 PPM SAMPLE AS PER MANUFACTURE'S INSTRUCTIONS.
Condition: Unknown
Due 26 June 1993
Resolved 26 June 1993
Construction/Loadline
Issued 26 June 1993
Resolved
PROVIDE ADEQUATE SUPPLY OF SPARE PARTS FOR OWS AS PER MANUFACTURE'S INSTRUCTIONS. DEMONSTRATE COMPLIANCE IN THE PRESENCE OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 26 June 1993
Resolved 26 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE DECK IN #7 HOLD WHERE TEMPORARY REPAIRS (DOUBLED AREAS)WERE MADE IN MAY 1993 AND ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
MAKE PERMANENT REPAIR TO THE WASTED LONGINTUDINAL FLOORS BETWEEN FRAMES 75-76, 76-77, 78-79, 79-80, & 80-81 IN #4 PORT DOUBLE BOTTOM.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT TEMPORARILY REPAIRED, WASTED TRANSVERSE AND LONGITUDINAL FLOORS AND UNDERDECK TRANSVERSE FRAMES THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL (BETWEEN FR 217 AND 238) IN THE AFT PEAK TANK AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE ENTIRE TANK TOP OF THE AFT PEAK TANK AS REQUIRED BY [name withheld] LETTER 16711 DATED 17 MAY 1993 AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE WASTED CENTERLINE SWASH BULKHEAD IN THE #6 DEEP TANK AT THE NEXT DRYDOCKING._x001C_ _x001C_
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE DECK IN #5 HOLD WHERE TEMPORARY REPAIRS (DOUBLED AREAS)WERE MADE IN MAY 1993 AND ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE DECK IN #6 HOLD WHERE TEMPORARY REPAIRS (DOUBLED AREAS)WERE MADE MAY 1993 AND ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL_x001C_ AT THE NEXT DRYDOCKING._x001C_ _x001C_
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE TANK TOPS FOR THE FORWARD ENGINE ROOM DOUBLE BOTTOMS AND THE STBD SHAFT ALLEY DOUBLE BOTTOMS WHERE TEMPORARY REPAIRS HAVE BEEN MADE AND ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE DISTORTED FLOORS UNDER THE INTERMEDIATE LINE SHAFT BEARING FOUNDATIONS IN THE #9 AND #10 STBD DOUBLE BOTTOMS AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE TANK TOPS OF THE #2 PORT AND STBD FRESH WATER TANKS (FRAMES 145-151) WHERE TEMPORARY REPAIRS (DOUBLED AREAS) WERE MADE JUNE 1993 AND ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL AT THE NEXT DRYDOCKING._x001C_
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE TANK TOPS OF THE #3 PORT AND STBD INBD DEEP TANKS (FRAMES 152-157) WHERE TEMPORARY REPAIRS (DOUBLED AREAS) WERE MADE IN JUNE 1993 AND ALL WASTED AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE TANK TOPS IN #5 PORT AND STARBOARD INBD DOUBLE BOTTOM IN ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE WASTED AND TEMPORARILY REPAIRED FRAMES (87-98) UNDER THEDISTILLED WATER TANK AND POTABLE WATER TANK IN THE FWD COFFERDAM AT NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE LOWER WASTED SECTION OF THE STANTION UNDER THE AIR COMPRESSOR UNITS AT THE STBD SIDE IN THE AUX MACHINERY ROOM.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
PROVE PROPER OPERATION OF THE CARGO BILGE PUMPING SYSTEM INCLUDING A TEST TO DETERMINE THE TIGHTNESS/INTEGRITY OF ALL SUCTION PIPING.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
SUBMIT FOR APPROVAL YOUR CRITICAL AREA INSPECTION PLAN (CAIP).
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
SUBMIT FOR APPROVAL A DETAILED PERMANENT REPAIR PROPOSAL FOR THE AFTER ENGINE ROOM AND PORT SHAFT ALLEY DOUBLE BOTTOM TANK TOP RENEWALS BASED ON THE ACTUAL GAUGE READINGS INDICATED ON THE RONALD NISBET ASSOC, INC. REPORTDATED 16OCT92.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Deck/Cargo
Issued 4 June 1993
Resolved
MAKE MODIFICATIONS TO THE CARGO HOLD PUMPING SYSTEM SO THAT IT IS SELF- PRIMING IN ACCORDANCE WITH 46 CODE OF FEDERAL REGULATIONS PART 56.50-50.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Electrical
Issued 4 June 1993
Resolved
PROVIDE COAST GUARD APPROVED ELECTRICAL PLANS FOR THE GALLEY MODIFICATIONS AND COOKING EQUIPMENT INSTALLATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE BOTTOMS AND SIDES OF THE POTABLE/DISTILLED WATER TANKS IN WAY OF THE FWD COFFERDAM WHERE TEMP REPAIRS (DOUBLED AREAS) HAVE BEEN MADE AND ALL AREAS THAT SHOW 25% WASTAGE OF ORIGINAL AT NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE FWD COFFERDAM FWD BULKHEAD (#87) WHERE TEMP REPAIRS (DOUBLED AREAS) HAVE BEEN MADE AND ALL AREAS THAT SHOW 25% WASTAGE OF ORIGINAL AT NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND INSERT THE TANK TOPS FOR THE AFT ENG RM DOUBLE BOTTOMS AND THE PORT SHAFT ALLEY DOUBLE BOTTOMS WHERE TEMPORARY REPAIRS HAVE BEEN MADE AND ALL AREAS THAT SHOW WASTAGE BEYOND 25% OF ORIGINAL, AT THE DRYDOCKING FOLLOWING THE NEXT DRYDOCKING.
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 June 1993
Resolved
CROP AND RENEW THE DISTORTED FLOORS UNDER THE INTERMEDIATE LINE SHAFT BEARING FOUNDATIONS IN THE #9 AND #10 PORT DOUBLE BOTTOM AT THE DRYDOCKING FOLLOWING THE NEXT DRYDOCKING._x001C_ _x001C_
Condition: Unknown
Due 1 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 4 June 1993
Resolved
REPAIR OR RENEW THE CRACKED CHLORINATOR UNIT FOR THE #2 MSD IN #6 HOLD.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
MAKE TEMPORARY REPAIRS TO HOLED AND WASTED TANK TOPS IN THE #2 PORT AND STBD FRESH WATER TANKS AND THE #3 PORT AND STBD INBD DEEP TANKS AS INDICATED ON THE SHAKA ENGINEERING, INC. GAUGING REPORT DATED 11 MAY 1993 _x001C_PRIOR TO PLACING VESSEL IN PASSENGER SERVICE._x001C_
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
SUBMIT TO COAST GUARD COMMANDANT G-MVI FOR APPROVAL A DETAILED PERMANENT REPAIR PROPOSAL FOR THE FORWARD ENGINE ROOM AND STARBOARD SHAFT ALLEY DOUBLE BOTTOM TANK TOP RENEWALS BASED ON THE ACTUAL GAUGE READINGS INDICATED ON THE RONALD NISBET ASSOC, INC. REPORT DATED 16OCT92._x001C_
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 4 June 1993
Resolved
MAKE PERMANENT REPAIRS TO THE TANK TOP OF THE #6 MSD UNIT IN THE #4 HOLD WHERE TEMPORARY REPAIRS WERE MADE MAY 1993.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In double bottom tank #6 port inboard, repair floors that are distorted andbuckling underneath boiler #1 and restore adequate strength to support the boiler.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In double bottom tank #4 stbd, gauge floors at frames # 78 - 80. Submit report to cognizant [name withheld] repairs to frames with more than 30% wastage.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In double bottom tank #6 port outboard, repair fwd and aft ladders, crop and renew the sounding tubes for this DB and #5 port outboard DB.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Engineering
Issued 24 April 1993
Resolved
#2 PORT DEEP TANK, RENEW SOUNDING TUBES FOR #2 DEEP TANK, FORWARD_x001C_ COFFERDAM, ALL #5 DOUBLE BOTTOM VENTS EXCEPT AFT PORT OUTBOARD. CROP AND RENEW AREA OF FRACTURE IN BULKHEAD #88 IN WAY OF LOWER LONGITUDINAL DEEP FRAME.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Engineering
Issued 24 April 1993
Resolved
#2 STARBOARD DEEP TANK; RENEW SOUNDING TUBES FOR #2 STBD DEEP TANK, STBD COFFERDAM, ALL #5 STBD DOUBLE BOTTOM VENTS, CROP AND RENEW AREA OF FRACTUREIN BULKHEAD #88 IN WAY OF LOWER LONGITUDINAL DEEP FRAME.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
Double bottom tank tops #4 port and stbd, remove sewage, rust and debris and gauge tank top on at least 36 inch intervals. Submit gauging report toMSO Honolulu.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In double bottom tank #6 port outboard, make temporary repairs to restore watertight integrity of the tank top under the evaporator and in the aft rose box.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In double bottom tank top #8 stbd inboard, frames 143-144, conduct temporary repairs to restore watertight integrity and local strength until permanent repairs can be accomplished.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In hold #7, make temporary repairs to aft watertight bulkhead to restore watertight integrity and gauge lower portion of fwd & aft bulkheads in areas that show excessive corrosion. Submit gauging report to [name withheld].
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In aft cofferdam, frames 145-151, remove all oil residue and gas free so structural condition of surrounding tanks can be evaluated.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Accommodation/Occupational Safety
Issued 24 April 1993
Resolved
In aft steering room, make permanent repairs to 5" overboard line port side.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In aft peak tank, crop and renew upper portion of floors between frames 232-236 and under port and stbd rudder rams frames 228-232, in way of areasthat show signs of working and distortion.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In double bottom tank top #8 stbd outboard, crop and renew wasted section of tank top under the evaporator and #3 aux condenser.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In aft peak tank, de-scale and gauge tank top frames below the steering machinery gear. Submit gauging report to cognizant [name withheld] repairs to frames with more than 30% wastage.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
Renew wasted sounding tube and ladder rungs in #2 starboard double bottom tank.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
Gauge lower 3 feet of bulkhead 63, Renew areas where wastage is greater than 25%._x001C_
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
Crop and insert doubled area of #2 port and starboard double bottom tank top between frames 62 and 63._x001C_
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Construction/Loadline
Issued 24 April 1993
Resolved
In hold #7, gauge deck on 36" centers to determine extent of repairs necessary and submit repair proposal to preserve longitudinal strength and make watertight. Submit report to [name withheld].
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Accommodation/Occupational Safety
Issued 24 April 1993
Resolved
In holds #6 & 7, repair all pipe lagging that is deteriorated and fragmented using asbestos handling precautions.
Condition: Unknown
Due 24 April 1993
Resolved 24 April 1993
Accommodation/Occupational Safety
Issued 13 March 1993
Resolved
CLEAN ALL SOOT FROM FORWARD AND AFT ENGINE ROOM STACK SPACES, ALL LEVELS.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Lifesaving
Issued 13 March 1993
Resolved
RENEW BOLTS IN ROTMER GEAR, LIFE BOAT #2
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Fire Fighting
Issued 13 March 1993
Resolved
REPAIR NUMBER 1 AND 2 FIRE PUMP UPPER AND LOWER SHAFTS AND PACKING TO STOP EXESSIVE LEAKING.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 13 March 1993
Resolved
PRIOR TO PLACING #1 BOILER BACK IN SERVICE THE REPAIRS TO THE SUPERHEATER MUST BE SATISFACTORY TO THE ATTENDING MARINE INSPECTOR AND THE SUPERHEATER HYDRO TESTED TO 150% MAWP, AND THE SAFETY VALVES SET AND SEALED.
Condition: Unknown
Due 13 March 1993
Resolved 13 March 1993
Accommodation/Occupational Safety
Issued 13 March 1993
Resolved
REPAIR TWO HOT WATER LESLIE VALVES ON "B" DECK IN WAY OF FORWARD ENGINE ROOM ENTRANCE.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 13 March 1993
Resolved
RENEW ENGINE EXHAUST IN LIFE BOAT #4
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Accommodation/Occupational Safety
Issued 13 March 1993
Resolved
RENEW WASTED VENT DUCT, PT.SIDE BETWEEN LIFE BOAT #8 AND LIFE BOAT #10, BT DECK
Condition: Unknown
Due 13 March 1993
Resolved 13 March 1993
Deck/Cargo
Issued 13 March 1993
Resolved
RENEW BOLTS IN FOUNDATION OF #6 FIFE BOAT WINCH
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Electrical
Issued 13 March 1993
Resolved
RENEW AS ORIGIONAL ,MARINE PLUG OUTLETS
Condition: Unknown
Due 13 March 1993
Resolved 13 March 1993
Accommodation/Occupational Safety
Issued 13 March 1993
Resolved
RENEW HOLED GRAY WATER CHECK VALVE ABOVE GRAY WATER COLLECTION TANK IN AFT STARBOARD SIDE OF AFT ENGINE ROOM.
Condition: Unknown
Due 13 March 1993
Resolved 13 March 1993
Construction/Loadline
Issued 4 February 1993
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED AREA IN WAY OF PORT BOW JUST BELOW THE MAIN DECK. TO BE COMPLETED AT DRY DOCK.
Condition: Unknown
Due 4 February 1993
Resolved 4 February 1993
Engineering
Issued 26 December 1992
Resolved
CROP AND RENEW WASTED PLATING ON UNDERSIDE OF #4 BOILER.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Fire Fighting
Issued 26 December 1992
Resolved
AT FIRE STATION 93 UNPLUG BOTH VALVES AND FLUSH FIREMAIN TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 January 1993
Resolved 11 January 1993
Accommodation/Occupational Safety
Issued 26 December 1992
Resolved
REPAIR LEAKS IN 2 INCH AND 4 INCH SEWAGE LINE IN CARGO HOLD #2.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Construction/Loadline
Issued 26 December 1992
Resolved
RENEW 2.5" VENT LINES TO 12 PORT AND 12 STARBOARD DOUBLE BOTTOM TANKS WITHIN 6 CENTERLINE DEEP TANK JUST FORWARD OF FRAME 196.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Electrical
Issued 26 December 1992
Resolved
REMOVE OR PROPERLY TERMINATE DEAD END CABLE RUNS IN THE AFT SIDE PORTS ABOVE CARGO HOLD #7 AND IN CARGO HOLD #4.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Accommodation/Occupational Safety
Issued 26 December 1992
Resolved
MAKE REPAIRS TO, OR RENEW SEWAGE COLLECTION TANKS #2,3,4,5,6,7,8, AND 9 TO STOP ALL LEAKS.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Engineering
Issued 26 December 1992
Resolved
REPAIR OR REPLACE WASTED SECTIONS OF SEA WATER INLET LINE TO #1 AUX CONDENSER BETWEEN THE CIRC PUMP AND CONDENSER.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Accommodation/Occupational Safety
Issued 26 December 1992
Resolved
REPAIR, RENEW OR REMOVE SEWAGE EJECTOR COLLECTION TANK ON LOWER LEVEL OF FWD ENGINE ROOM, STBD SIDE.
Condition: Unknown
Due 26 December 1992
Resolved 26 December 1992
Lifesaving
Issued 19 September 1992
Resolved
REPAIR OR REPLACE THE LIMIT SWITCHES FOR & AFT ON LIFEBOAT DAVIT #7 (REF: 46CFR 111.95-7(C))
Condition: Unknown
Due 19 September 1992
Resolved 19 September 1992
Construction/Loadline
Issued 19 September 1992
Resolved
REINSTALL REFRIGERATION PRESSURE RELIEF PIPING IN THE AUXILIARY MACHINERY COMPARTMENT IN ACCORDANCE WITH 46CFR 58.20-20(C)
Condition: Unknown
Due 19 September 1992
Resolved 19 September 1992
Engineering
Issued 25 June 1992
Resolved
REPAIR OR REPLACE THE OVERSPEED TRIP VALVE ON THE #2 MAIN FEED PUMP IN THE FORWARD ENGINE ROOM.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 25 June 1992
Resolved
ON LIFEBOAT #1 REPLACE WASTED BOLTS ON THE AFT ROTTMER RELEASE GEAR BRACE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 25 June 1992
Resolved
ON LIFEBOAT #3, MAKE REPAIRS TO AFT RELEASE GEAR CONNECTION ROD AT THE UNIVERSAL JOINT WHERE WASTED.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 25 June 1992
Resolved
ON LIFEBOAT #5, REPLACE WASTED BOLTS ON THE AFT ROTTMER RELEASING GEAR AND REPAIR BOTH FLEMMING GEAR DRIVE BARS WHERE WASTED.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Accommodation/Occupational Safety
Issued 25 June 1992
Resolved
MODIFICATIONS AND REPAIRS TO THE FLASHING AND EQUIPMENT OF THE MAIN AND CREW GALLEYS, REQUIRED BY THE FDA TO PROVIDE CLEANLINESS AND A SANITARY ENVIRONMENT, SHALL BE COMPLETED BY THE COMPLETION OF THE NEXT DRYDOCKING.
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Electrical
Issued 25 June 1992
Resolved
REPAIR OR REPLACE THE AUTO-START BREAKER TRIP FOR THE EMERGENCY GENERATOR AND CONDUCT A DROP LOAD AND 2 HOUR FULL LOAD TEST.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Accommodation/Occupational Safety
Issued 25 June 1992
Resolved
REPAIR VARIOUS VENTILATION DUCTING, COVERS, DOGS AND SCREENS ON THE FOCSLE DECK WHERE MISSING OR WASTED.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Construction/Loadline
Issued 21 March 1992
Resolved
CROP TO GOOD METAL AND MAKE PERMANENT REPAIRS TO THE SHAFT ALLEY BILGE SUCTION LINE LOCATED IN WAY OF THE AFT ENGINE ROOM (STBD SIDE) BY SHAFT ALLEY_x001C_ W.T.D.
Condition: Unknown
Due 21 March 1992
Resolved 21 March 1992
Construction/Loadline
Issued 21 March 1992
Resolved
MAKE PERMANENT REPAIRS BY REPLACING ALL WASTED FASTENERS (STUDS AND NUTS) IN WAY OF ALL MOUNTS AND VALVE FLANGES, LOCATED ON THE STBD SIDE, IN THE AFTER ENGINE ROOM BILGE SUCTION MANIFOLD.
Condition: Unknown
Due 21 March 1992
Resolved 21 March 1992
Construction/Loadline
Issued 21 March 1992
Resolved
CROP TO GOOD METAL AND MAKE PERMANENT REPAIRS TO WASTED SECTION OF THE AFT PEAK TANK OVERFLOW DISCHARGE LINE IN WAY OF THE PORT SIDE, STEERING ROOM. _x001C_
Condition: Unknown
Due 21 April 1992
Resolved 13 April 1992
Lifesaving
Issued 21 March 1992
Resolved
NO.9 L/B HAS BEEN CONDEMNED AND WILL BE REMOVED FROM VSL UNTIL SATISFACTORYREPAIRS HAVE BEEN MADE. PASSENGERS AND CREW WILL CONTINUE TO MUSTER AT L/BSTATION NO.9 BUT WILL BE DIRECTED TO ALTERNATE L/B'S BY THE MASTER OR NEXT IN COMMAND. TOTAL PERSONS ONBOARD SHALL BE REDUCED TO 1106 TOTAL._x001C_
Condition: Unknown
Due 21 March 1992
Resolved 21 March 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN WAY OF THE GALLEY AREAS WHERE STOVES AND EQUIPMENT ARE JOINED TOGETHER BY WELDING AND LEAVING PITS AND MOUNDS THAT ARE NOT SMOOTH AND CLEANABLE, SHALL BE GROUND OR FILLED IN PROPERLY._x001C_ _x001C_
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN THE CREW AND MAIN GALLEY WHERE THE HOBART REFRIGERATORS ARE INSTALLED, DRAIN PIPES FOR CONDENSATE SHALL BE PLUMBED TO A FLOOR DRAIN. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN THE FOOD PREPARATION AREAS OF BOTH GALLEYS WHERE TABLES AND COUNTERS HAVE BEEN WELDED LEAVING PITS AND MOUNDS THAT ARE NOT SMOOTH AND CLEANABLE,THEY SHALL BE GROUND OR FILLED IN PROPERLY.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN THE AREAS THROUGHOUT THE GALLEY WHERE FOOD IS BEING PREPARED USING UTENSILS THERE SHALL BE INSTALLED CONVENIENT CLEANABLE HOOKS SO UTENSILS CAN BE PLACED BETWEEN USE AND STORAGE.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN WAY OF THE GALLEY BAKERY, COLD JUICE ROOM AND ENGINE MESS WHERE DECK DRAINS ARE PLUGGED, THEY SHALL BE PROPERLY CLEANED OUT AND REPAIRED SO GRAYWATER CAN EASILY FLOW.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN WAY OF THE GARBAGE STOWAGE ROOM, INSTALL RODENT PROOFING OVER VENTS TO PREVENT VERMIN INGRESS AND EGRESS, AND REPAIR PENETRATIONS IN BULKHEADS, AND OVERHEADS TO MAINTAIN INSULATION STANDARDS TO A-60. _x001C_ _x001C_
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
WHERE CLEAN POTS AND PANS ARE STOWED SO THAT THEY MUST COME IN CONTACT WITHBULKHEAD SURFACES THAT CANNOT BE PROPERLY SANITIZED, FLASHING OR ADEQUATE SHELVING MUST BE INSTALLED SO THAT CLEAN POTS AND PANS DO NOT COME IN CONTACT WITH UNSANITIZABLE SURFACES.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
THROUGHOUT THE CREW GALLEY, THE BULKHEADS, SIDE SHELL, AND OVERHEAD FLASHING MUST BE PERMANENTLY REPAIRED AND SEALED IN WAY OF HOLES AND FRACTURES THAT CAN PROVIDE ROACH HARBORAGE.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN CREW HEAD IN WAY OF B-DECK FWD, ADJACENT TO CB-33, INSTALL SPLIT (OPEN FRONT) TOILET SEATS AND CAULK AROUND THE BASE OF THE FIXTURES. _x001C_(REF46CFR72.20-25) _x001C_ _x001C_
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
WHERE EQUIPMENT IS INSTALLED TO CLOSE TO ALLOW FOR CLEANING, AND WHERE FLASHING IS PULLED AWAY FROM BULKHEADS AND SIDE SHELL LEAVING GAPS WHICH SERVE AS ROACH HARBORAGE, THESE AREAS MUST BE CLEANED OUT AND SECURED BY SEALING TO PREVENT ENTRY WAYS FOR INSECTS AND LIQUIDS TO SEEP.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN WAY OF THE VEGETABLE PREP ROOM OF THE MAIN GALLEY AND COLD STORAGE AREASON C-DECK, WHERE CONDENSATION IS FORMING AND DRIPPING FROM THE OVERHEAD, THERE SHALL BE ADEQUATE VENTILATION INSTALLED TO PREVENT CONDENSATION OR REDUCE THE AMOUNT OF HUMIDITY.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN THE CREW GALLEY FOOD PREP AREA AND THE MAIN GALLEY VEGETABLE PREP AREA, A PROPER HAND WASHING SINK FACILITY SHALL BE INSTALLED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
IN WAY OF THE TROUGH DRAINS IN THE MAIN AND CREW GALLEY WHERE THERE IS INSUFFICIENT SLOPE TO DRAIN STANDING WATER, THEY SHALL BE CLEANED, MODIFIEDAND OR REPAIRED SO THAT GRAY WATER CAN EASILY FLOW AND DRAIN.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Accommodation/Occupational Safety
Issued 29 February 1992
Resolved
REPAIR OR REPLACE THE VENT DUCT AND LAGGING OVER THE ENTRANCE TO THE BUTCHER SHOP.
Condition: Unknown
Due 29 February 1992
Resolved 29 February 1992
Lifesaving
Issued 16 January 1992
Resolved
TOTAL NUMBER OF ADULT PERSONS (PASSENGERS ADN CREW) THAT CAN BE CARRIED ON BOARD IS LIMITED TO THE NUMBER OF APPROVED LIFE PRESERVERS, CURRENTLY 1334.
Condition: Unknown
Due 1 February 1992
Resolved 5 February 1992
Fire Fighting
Issued 16 January 1992
Resolved
REPAIR A-60 BULKHEAD AND FIRE SCREEN DOOR IN SERVICE LOCKER #7, IN WAY OF STAIR TOWER ON C-DECK AFT.
Condition: Unknown
Due 19 March 1992
Resolved 5 February 1992
Lifesaving
Issued 16 January 1992
Resolved
REPAIR OR REPLACE THE PA SYSTEM SPEAKERS LOCATED ON D-DECK AFT, D-DECK DRY STORES, C-DECK AFT, C-DECK BY BUTCHER STORES, C-DECK BY CB-11 & FS95, B- DECK PASSAGE AFT OF ENG OFF, B-DECK BY CB-11, A-DECK BY CAW-1 AND CA-3
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 16 January 1992
Resolved
INSTALL PROTECTIVE CAGES AROUND KNOCK-OUT PLUGS IN THE FRESH VEG. REFER, FRESH FRUIT REFER, EGGS & BUTTER REFER, AND THE ICE CREAM REFER.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 16 January 1992
Resolved
RENEW WASTED SECTION OF 2 INCH SEWAGE LINE IN AFT ENGINE ROOM BEHIND NO. 4 BOILER AND ABOVE STBD SHAFT BEARING.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Fire Fighting
Issued 16 January 1992
Resolved
REPAIR OR REPLACE PHOTO SENSING SYSTEM IN SMOKE DETECTOR AND PROVE OPERATION OF THE SMOKE SENSING SYSTEM FOR THE C AND D DECKS. SET AN HOURLYWATCH TO CHECK THE SPACES PROTECTED BY THE SMOKE DETECTION SYSTEM.
Condition: Unknown
Due 18 January 1992
Resolved 24 January 1992
Engineering
Issued 16 January 1992
Resolved
REPAIR OR REPLACE TANK VENT SCREENS (30X30 MESH) ACCORDING TO VENT SCREEN WORKLIST ISSUED 17JAN92.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 10 December 1991
Resolved
CROP AND RENEW WASTED FLOORS AND FRAMES IN STBD SIDE OF THE FORWARD COFFERDAM.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Construction/Loadline
Issued 10 December 1991
Resolved
CROP AND RENEW WASTED SECTION OF FORWARD VENT LINES OF NO. 5 PORT AND STBD INBD DOUBLE BOTTOM TANKS.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Construction/Loadline
Issued 10 December 1991
Resolved
CROP AND RENEW WASTED SECTIONS OF NO. 6 PORT OUTBD DOUBLE BOTTOM TANK TOP AND FORWARD LADDER RUNGS.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Construction/Loadline
Issued 10 December 1991
Resolved
UT GAUGE EXPOSED PORTIONS OF POTABLE WATER AND FUEL TANK AND BULKHEADS AT FRAMES 78 AND 87 IN THE FORWARD COFFERDAM, AND PROVIDE THE REPORT TO MSO HONOLULU.
Condition: Unknown
Due 8 February 1992
Resolved 12 March 1992
Navigation
Issued 26 October 1991
Resolved
PROVE PROPER OPERATION OF BOTH SOUND POWERED PHONE BELLS AND RINGER CIRCUITS IN THE STEERING GEAR ROOM.
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Construction/Loadline
Issued 26 October 1991
Resolved
UT GAUGE #6 PORT INBOARD DOUBLE BOTTOM TANK TOP TO DETERMINE EXTENT OF PLATING TO BE RENEWED.
Condition: Unknown
Due 8 November 1991
Resolved 13 November 1991
Construction/Loadline
Issued 26 October 1991
Resolved
INSTALL AN ACCESS MANHOLE INTO THE NO. 1 DOUBLE BOTTOM TANK VIA THE NO. 2 DOUBLE BOTTOMS AND MUCK OUT AREA BETWEEN LONGITUDINAL FLOORS. _x001C_
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Electrical
Issued 26 October 1991
Resolved
INSTALL VENTILATION BLOWER FOR BATTERY ROOM WITH INTERLOCK TO THE BATTERY CHARGER IN ACCORDANCE WITH 46 CFRR 111.15-5
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Construction/Loadline
Issued 26 October 1991
Resolved
OPEN, GAS FREE AND CLEAN FOR INSPECTION THE FOLLOWING: NO.5 P&S INDB & OUTBD DB, NO.6 OUTBD DB, NO.7 STBD IN & OUTBD DB, NO.7 PORT INDBD DB, AND COFFERDAM FR 87-88 NOTE: DB= DOUBLE BOTTOM, OUTBD= OUTBOARD
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Construction/Loadline
Issued 26 October 1991
Resolved
IN #6 HOLD, REMOVE THE UNUSED PIPE AND ELIMINATE NONMETALLIC PIPING AND REPLACE WITH METALLIC PIPING.
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Fire Fighting
Issued 26 October 1991
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING FIRE DAMPERS: # 127, 148, 149, 146, 147.
Condition: Unknown
Due 8 November 1991
Resolved 13 November 1991
Construction/Loadline
Issued 26 October 1991
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING WATERTIGHT DOORS: # 7B, 9B, 13B AND 20B.
Condition: Unknown
Due 3 November 1991
Resolved 5 November 1991
Documentation
Issued 14 September 1991
Resolved
OBTAIN PLAN APPROVAL FOR ELECTRICAL INSTALLATION OF NEWLY INSTALLED MSD SYSTEM, REF 46CFR110.25 INCLUDING GROUND DETECTION FOR NEW STEP DOWN TRANSFORMER, REF 46CFR111.05-21(d).
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Construction/Loadline
Issued 14 September 1991
Resolved
REPAIR FOUR OUTBOARD CHANNEL STIFFENERS ON BULKHD 128 THAT HAVE FRACTURED AWAY FROM BULKHD. RENEW AS NEEDED SECTIONS WITH 35% WASTAGE AND PROVIDE GAUGING REPORT TO SUPPORT THE SAME.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Construction/Loadline
Issued 14 September 1991
Resolved
OPEN, GAS FREE & CLEAN FOR INSPECTION THE FOLLOWING: NO.1 CL DB, NO.4 P&S DB, NO.5 P&S INBD & OUTBD DB, NO.5 P&S DEEP TANKS, NO.6 P&S IN & OUTBD DB, NO.7 STBD IN & OUTBD DB, NO.7 PORT INBD DB, NO.8 STBD IN & OUTBD DB, NO.11 PORT DB, AND COFFERDAM FR 87-88. NOTE: DB=DOUBLEBOTTOM, OUTBD=OUTBOARD
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Accommodation/Occupational Safety
Issued 14 September 1991
Resolved
REPAIR LADDER RUNGS IN NO. 8 PORT INBOARD & OUTBOARD DOUBLEBOTTOMS.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Accommodation/Occupational Safety
Issued 14 September 1991
Resolved
DEMONSTRATE PROPER INSTALLATION AND OPERATION OF NEW MARINE SANITATION DEVICE(MSD)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Lifesaving
Issued 14 September 1991
Resolved
REPAIR FLEMMING GEAR ON NO. 5 LIFEBOAT.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Lifesaving
Issued 14 September 1991
Resolved
CROP & RENEW WASTED STANCHIONS IN MACHINERY SHOP/COMPRESSOR ROOM SPACE (FR115-128) AS NEEDED.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Construction/Loadline
Issued 14 September 1991
Resolved
Demonstrate satisfactory hydro(static head) of No. 9 port & stbd inboard doublebottom tanktops.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Engineering
Issued 14 September 1991
Resolved
MAKE PERMANENT REPAIRS TO AFT VENT PIPE FROM DOUBLE BOTTOM TANK NO.9 STBD OUTBOARD. UPON COMPLETION OF REPAIRS, HYDRO PIE IN PRESENCE OF CG INSPECTOR. IN ADDITION CONDUCT HYDRO OF FWD VENT PIPE NO.9 P&S OUTBD AND NO.9 AFT OUTBOARD PORT.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Construction/Loadline
Issued 14 September 1991
Resolved
Make permanent repairs to No. 2 port doublebottom tanktop at aft bulkhead of no.2 hold. Submit gauging report of tanktop plating thickness and drawing of repair proposal to OCMI prior to repairs.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Construction/Loadline
Issued 14 September 1991
Resolved
MAKE REPAIRS TO NO.4 CENTERLINE DEEP TANK AS FOLLOWS: A)CROP & RENEW ENTIRELONG CL SWASH BULKHD, B)CROP & RENEW UPPER & LOWER TRANSVERSE CL SWASH BULKHD, D)CROP & RENEW ENTIRE TANKTOP, E)CROP & RENEW I-BEAM PILLERS AT FR 163 P&S SUPPORT FOR SWASH BULKHD.
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Construction/Loadline
Issued 14 August 1991
Resolved
RENEW WASTED SECTION OF FORWARD VENT LINE AND ALL FORWARD LADDER RUNGS IN #7 PORT INBOARD DOUBLE BOTTOM TANK.
Condition: Unknown
Due 18 November 1991
Resolved 18 November 1991
Engineering
Issued 14 August 1991
Resolved
REPAIR OR REPLACE WASTED SECTION OF DISCHARGE LINE FOR #3 AUXILIARY CONDENSATE CIRC PUMP.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 14 August 1991
Resolved
UT IN PRESENCE OF COAST GUARD MARINE INSPECTOR, THE ENTIRE TANK TOP OF #6 PORT OUTBOARD DOUBLE BOTTOM TANK AT INTERVALS OF 4 FOOT CENTERS. THIS IS TODETERMINE EXTENT OF PLATE TO BE RENEWED.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 14 August 1991
Resolved
CROP TO GOOD METAL AND RENEW WASTED SECTION OF #6 PORT INBOARD DOUBLE BOTTOM TANK TOP. TO BE COMPLETED AT NEXT DRYDOCK BUT NO LATER THAN 15 MAR 93.
Condition: Unknown
Due 14 August 1991
Resolved 14 August 1991
Construction/Loadline
Issued 14 August 1991
Resolved
COMPLETE PERMANENT REPAIRS TO AFT STEERING ROOM DECK BY 1) PLUG WELDING DECK PLATING, 2) REMOVING BACKING STRIPS UNDERNEATH, THEN GOUGING AND REWELDING SEAMS, AND 3) GAUGING DECK FRAMES AND RENEWING THOSE WITH MORE THAM 25% WASTAGE.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Accommodation/Occupational Safety
Issued 29 June 1991
Resolved
RENEW FWD MAIN SEWAGE LINE PASSING THROUGH CARGO HOLDS # 2 & 3 BETWEEN FRAMES 60-75.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Deck/Cargo
Issued 29 June 1991
Resolved
MAKE STERN THRUSTER OPERABLE AND DEMONSTRATE PROPER OPERATION IN THE PRESSENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Electrical
Issued 29 June 1991
Resolved
RENEW NON METALIC EXPANSION JOINTS ON UPPER LUBE OIL COOLER IN FWD ENGINE ROOM AND ON LOWER LUBE OIL COOLER IN AFT ENGINE ROOM.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Lifesaving
Issued 29 June 1991
Resolved
REPAIR AND DEMONSTRATE OPERATION OF FLEMMING GEAR IN LIFEBOATS NOS. 5 & 8
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Electrical
Issued 29 June 1991
Resolved
EFFECT NECESSARY REPAIRS TO EMERGENCY DIESEL GENERATOR AND DEMONSTRATE 1) PROPER OPERATION OF UNIT UNDER FULL LOAD AND 2) OVERSPEED DEVICE OPERATION.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Accommodation/Occupational Safety
Issued 29 June 1991
Resolved
MAKE NECESSARY REPAIRS/RENEWALS TO LEAKING 2" AND 4" VENT LINES IN PORT SIDE MAIN DECK GANGWAY EMBARKATION AREA, PRIOR TO COMPLETION OF NEXT DRY DOCKING.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Accommodation/Occupational Safety
Issued 29 June 1991
Resolved
RENEW SANITARY WATER PIPING IN OVERHEAD OF STEERING GEAR SPACE PRIOR TO COMPLETION OF NEXT DRYDOCKING. METALIC PIPING TO BE INSTALLED OR METALIC VALVES REQUIRED AT ALL OVERHEAD & BULKHEAD PENETRATIONS.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Electrical
Issued 29 June 1991
Resolved
INSTALL PROPER EXPLOSION PROOF FITTING ON ELECTRICAL EQUIPMENT FOR LIGHTINGAND POWER VENTILATION IN FWD PAINT LOCKER.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Accommodation/Occupational Safety
Issued 29 June 1991
Resolved
RENEW 2" SEWAGE PIPING IN OVERHEAD OF SHAFT ALLEY, PORTSIDE PRIOR TO COMPLETION OF NEXT DRYDOCKING.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Construction/Loadline
Issued 29 June 1991
Resolved
RENEW FRAME AND COAMING FOR WATERTIGHT DOORS #2 & 3 ON BRIDGE DECK AND MAKENECESSARY ADJUSTMENTS TO DOORS AND OR DOGS
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Unknown
Issued 19 March 1991
Resolved
RESTORE INSULATING PROPERTIES OF #2 BOILER TO ORIGINAL SPECIFICATIONS._x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
CLEAN AND FREE UP SLIDING FEET ON ALL (4) BOILER MUD DRUMS AND PROVIDE A MEANS OF LUBRICATING THE FEET FOR FUTURE MAINTENANCE.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
PROVIDE GAUGINGS OF LOWER 18" OF AFT BULKHEAD OF #2 CARGO HOLD.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Fire Fighting
Issued 19 March 1991
Resolved
INSTALL AUTOMATIC SPRINKLER SYSTEM IN UPPER DECK GIFT SHOP AREA IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
RENEW WASTED SECTIONS OF DECK IN WAY OF #6 AND #7 CARGO HOLD BOTTOMS PRIOR TO COMPLETION OF NEXT DRYDOCKING. _x001C_ REF: SEE B.R.W. GAUGING REPORT DATED 17NOV90 FOR IDENTIFICATION OF AREAS INEXCESS OF 25% WASTAGE.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
INSTALL PROPER INSERT IN HOLED TANKTOP OF #8 STBD INBOARD DOUBLE BOTTOM TANK, PRIOR TO COMPLETION OF NEXT DRYDOCKING.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
RENEW WASTED SECTIONS OF 2.5" SANITARY LINE IN FWD ENGINEROOM AT BASE OF FORWARD LADDER AND WASTED SCUPPER LINE BEHIND #2 SWITCHBOARD PRIOR TO COMPLETION OF NEXT DRYDOCKING.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
RENEW WASTED PORTIONS OF VERTICAL BULKHEAD STIFFNERS AT BOTTOM OF AFT BULKHEAD IN #2 CARGO HOLD, PRIOR TO COMPLETION OF NEXT DRYDOCKING.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991
Resolved
RENEW WASTED SECTION OF OVERHEAD IN SHAFT ALLEY ON FWD END, PORT SIDE, PRIOR TO COMPLETION OF NEXT DRYDOCKING.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Lifesaving
Issued 17 July 1990
Resolved
REVISE FIRE CONTROL PLAN PER COMMENTS MADE DURING FIRST QUARTERLY REINSPECTION AND RE-SUBMIT PLAN FOR APPROVAL. NOTE: A COPY OF THE DRAFT PLAN WAS HAND CORRECTED DURING THE INSPECTION. THE REVISED VERSION MUST INCORPORATE THE CORRECTIONS FOUND AT THAT TIME.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Accommodation/Occupational Safety
Issued 4 March 1990
Resolved
REPAIR DETERIORATED GALLEY DRAIN LINE ADJACENT TO TRANSFORMERS IN AFT ENGINE ROOM ACCESS VESTIBULE.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
RENEW FORWARD FIREMAIN PRESSURE GAGE.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
PROVIDE ONE ADDITIONAL NON-BOUYANT PROJICTLE FOR LINE THROWING GUN AND CLEAN GUN.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
INSTALL SAFETY MESH ON BOTTOM OF DAVIT ARMS LIFE BOATS 1, 3, AND 5.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
REPAIR PREVENTER ON AFT BOAT FALL HOOK, LIFE BOAT #2.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Construction/Loadline
Issued 4 March 1990
Resolved
PLUG OPEN PENETRATIONS FROM CARGO HOLDS #5, #6, #7 AND LAUNDRY ROOM INTO SHAFT ALLEY.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
PROVIDE NON-CLOG TIP FOR FOG APPLICATOR AT FIRE STATION 109.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Construction/Loadline
Issued 4 March 1990
Resolved
PROVIDE STOP VALVES FOR ALL DRAIN LINES IN SHAFT ALLEY.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Engineering
Issued 4 March 1990
Resolved
REPAIR EXCESSIVELY LEAKING STERN THRUSTER SHAFT GLANDS.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Electrical
Issued 4 March 1990
Resolved
INSTALL HIGH COOLANT TEMP. ALARM ON EMERGENCY GENERATOR.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Accommodation/Occupational Safety
Issued 4 March 1990
Resolved
REPLACE ALL PLASTIC WASTEBASKETS/GARBAGE CANS WITH METAL TYPE PER 46CFR72.05-55(B)
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
PROVIDE COMPLETE RECORDS OF ANNUAL SERVICING OF FIREFIGHTING EQUIPMENT PER 46CFR78.17.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
PROPERLY SECURE AND LABEL WITH STATION NUMBERS ALL MACHINERY SPACE PORTABLEFIRE EXTINGUISHERS
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
RENEW DETERIORATED AREA OF #2 CARGO HOLD LOWER TWEEN DECK STARBOARD AFT CORNER BEHIND MSD UNIT.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Construction/Loadline
Issued 4 March 1990
Resolved
MAKE REPAIR TO FUEL OIL WEEPS #1 PORT FUEL OIL SETTLING TANK BEHIND AUX CONDENSER AIR EJECTOR UNIT, #3 PORT OUTBOARD DEEP FUEL OIL TANK PORT AFT CORNER OF AFT ENGINEROOM
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Engineering
Issued 4 March 1990
Resolved
LABEL ALL FORWARD ENGINEROOM FEED PUMP GAGES.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Engineering
Issued 4 March 1990
Resolved
REPAIR LEAKS TO #1 AIR COMPRESSOR AFTER COOLER LINE.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Engineering
Issued 4 March 1990
Resolved
REPAIR EXCESSIVELY LEAKING FORWARD ENGINEROOM REDUCTION GEAR JACKING GEAR CASING
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Engineering
Issued 4 March 1990
Resolved
REPAIR EXCESSIVELY LEAKING FORWARD ENGINEROOM LUBE OIL SUPPLY LINE SIGHT GLASS.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
REPAIR BROKEN ANGLE ON STARBOARD SIDE OF LIFE BOAT 4 AS POINTED OUT TO [name withheld] WASTED METAL AT RELEASING BAR.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
RENEW DETERIORATED SECTIONS OF STRUCTURAL FIRE PROTECTION ON OVERHEADS OF CARGO HOLDS 5, 6, AND 7 IN VACINITY OF PIPE PENETRATIONS.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Electrical
Issued 4 March 1990
Resolved
PROVIDE LIGHTS, GLOBES AND GUARDS WHERE MISSING IN ALL CARGO HOLDS.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Electrical
Issued 4 March 1990
Resolved
EXAMINE ALL LINEN LOCKERS AND STEWARD SERVICE LOCKERS FOR UNAUTHORIZED FLAMABLE LAMP SHADES. PROVIDE LAMP GLOBES/GUARDS WHERE MISSING.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
RE-RIVET WHERE RIVETS MISSING BOTTOM OF LIFE BOATS 5, 6, 10 AND 12.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Electrical
Issued 4 March 1990
Resolved
REPAIR ELECTRICAL CABLE SUPPORT AT HOUSE FRONT PORT SIDE.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Electrical
Issued 4 March 1990
Resolved
LIGHTING PANEL L2-143 IN GALLEY ALOHA DECK HAS OPEN FRONT. PROVIDE COVER.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Accommodation/Occupational Safety
Issued 4 March 1990
Resolved
PROVIDE DECK DRAIN COVERS AT DISH WASHER MACHINE ALOHA DECK GALLEY.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Construction/Loadline
Issued 4 March 1990
Resolved
REPLACE GATE AND MIDDLE RAIL FORWARD AT LIFE BOAT 11 CONTROLLER ACCESS.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
PROVIDE 105 ADULT LIFE JACKETS (ADDITIONAL). CERTIFICATE OF INSPECTION LIMITED TO 1306 TOTAL PERSONS UNTIL THIS REQUIREMENT MET.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
FOLLOWING FIRE SCREEN DOORS REQUIRE ADJUSTMENT OR PARTS; SUN DECK 3 AND 6, PROM DECK 1, 11 AND 12, UPPER DECK 7, 13 AND 16, MAIN DECK 7 AND 16 ALOHA DECK 3, 13, 17, 29, 37, 18, AND 12, BALI DECK 9, 10, 22 AND 25.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Fire Fighting
Issued 4 March 1990
Resolved
FOLLOWING LOCAL FIRE ALARM STATIONS NEED BREAK GLASS HAMMERS; CORAL DECK 9 ALOHA DECK 53 AND 48 PROM DECK 18 PORT SIDE, MAIN DECK 56
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
REPLACE RING LIFE BOUY LIGHTS AT MAIN DECK, STARBOARD, AFT MOST AND UPPER DECK, STARBOARD, AFT MOST.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Accommodation/Occupational Safety
Issued 4 March 1990
Resolved
INSULATE EXPOSED STEAM LINES IN LAUNDRY.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
RE-RIVET 5 IN A ROW ON LIFE BOAT 9 PORT BOTTOM OF BOAT
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Construction/Loadline
Issued 4 March 1990
Resolved
CLEAR DEBRIS AT LOCAL HAND OPERATING STATIONS BOTH SIDES WATER TIGHT DOOR D-1. COAST GUARD TO TEST UPON COMPLETION.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Lifesaving
Issued 4 March 1990
Resolved
INSTALL GRAB LINE SEINE FLOATS ON LIFE BOAT 6 (TOTAL 3) AND REPAIR BROKEN/ ROTTED THWART FORWARD.
Condition: Unknown
Due 4 March 1990
Resolved 4 March 1990
Engineering
Issued 9 February 1990
Resolved
COMPLETE HIGH PRESSURE WASHDOWN OF STEAM DRUM AND ASSOCIATED BOILER TUBE INTERNALS, AND GENERATING & SUPERHEATER TUBE EXTERIORS. COMPLETE HYDRO TESTPRIOR TO PLACING BOILER BACK ON LINE.
Condition: Unknown
Due 9 February 1990
Resolved 9 February 1990
Engineering
Issued 9 February 1990
Resolved
REBRICK #1 BOILER ROOF, SIDE, & REAR WALLS AND RENEW DETERIORATED SECTIONS OF CASTABLE REFRACTORY UNDER STEAM DRUM & IN SUPERHEATER VESTIBULE. RENEW BUCKLED SECTION OF REAR WALL INTERIOR CASING & DETERIORATED SECTION OF FRONT WALL INTERIOR CASING ADJACENT TO MUD DRUM.
Condition: Unknown
Due 9 February 1990
Resolved 9 February 1990
Lifesaving
Issued 3 February 1990
Resolved
RENEW THE FOLLOWING SECTIONS OF LIFEBOAT DAVIT TRACKWAYS: #1 LIFEBOAT UPPERTRACK MIDLENGTH, #1 LIFEBOAT AFT LOWER OUTBOARD END, #5 LIFEBOAT FWD AND AFT LOWER OUTBOARD ENDS, #10 LIFEBOAT AFT LOWER OUTBOARD END, AND #12 LIFEBOAT FWD LOWER OUTBOARD END.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
PROVE PROPER OPERATION OF FIRE DAMPER NO. 23 IN FAN ROOM 4A.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
PROVE PROPER OPERATION OF FIRE DAMPERS 65 AND 66.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
PROVE PROPER OPERATION OF FIRE DAMPER AT LIFEBOAT STATION 12 IN BOAT DECK WEATHER DECK PASSAGEWAY TO SUN DECK INCLUDING PERMANENT REPAIR TO DECK PENETRATION ADJACENT TO SAME FIRE DAMPER IN SAME SPACE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990
Resolved
MAKE FINAL REPAIRS TO BOILER UPTAKE SECTIONS: ONE 6" HOLE ON FORWARD OUTBOARD SECTION AND ONE 6" HOLE ON AFT OUTBOARD SECTION ON"B" DECK ON #3 BOILER, INBOARD FORWARD CORNER OF AIR HEATER UPTAKE ON #1 BOILER & INBOARD FORWARD CORNER ON "A" DECK IN FRONT OF D.C. HEATER ON #1 BOILER.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
MAKE PERMANENT REPAIRS TO AFT STEERING ROOM DECK, AT NEXT DRYDOCK.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
REPLACE DAMAGED OR INSTALL MISSING GASKETS ON ALL SIDE PORTS.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
REPLACE EXPANSION JOINT, UPPER OF TWO 10"/12" EXPANSION IN AFT ENGINE ROOM,PORTSIDE, COMING FROM MAIN CONDENSER.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
CROP OUT AND RENEW FOUNDATION OF BILGE AND BALLAST PUMPS IN AFT ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
PROVIDE COAST GUARD APPROVED PLANS AND MATERIAL SPECIFICATIONS FOR MODIFICATIONS TO OWNER'S SUITE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
PROVIDE DATES OF MANUFACTURE & INSTALLATION FOR ALL EXPANSION JOINTS. REPLACE ALL EXPANSION JOINTS GREATER THAN 10 YEARS OF MANUFACTURE IAW NEW PIPING REGULATIONS EFFECTIVE 01NOV89; 46CFR61.15-12(B).
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR PROPER INSTALLATION OF ALL GLASS BULKHEADS ON VESSEL.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
REPLACE PVC DECK PENETRATION IN STARBOARD SHAFT ALLEY IN WAY OF #5 DEEP TANK WITH METALLIC FIXED PIPING & ISOLATION VALVE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Construction/Loadline
Issued 3 February 1990
Resolved
RENEW BILGE AND BALLAST MANIFOLD IN AFT ENGINE ROOM, STARBOARD SIDE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Electrical
Issued 3 February 1990
Resolved
REPLACE RELAY NO. 27B ON EMERGENCY SWITCHBOARD AND PROVE PROPER OPERATION
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
PROVE PROPER OPERATION TO FIRE DAMPER NO. 18 IN FAN ROOM 3A.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
CROP OUT AND RENEW APPROXIMATELY 25 FEET BETWEEN RESPECTIVE FLANGES OF SEWAGE LINE APPROXIMATELY 8 FEET ABOVE THE DECK PLATES AND 6 FEET FORWARD OF AFT BULKHEAD IN AFT ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
RENEW WHERE WASTED OR REPLACE WHERE MISSING DECK PLATE STANCHIONS IN FORWARD AND AFT ENGINEROOMS.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FLANGE BOLTS AND NUTS AT NO. 2 MAIN CIRC PUMP SUCTION VALVE BETWEENCIRC PUMP AND BILGE INJECTOR VALVE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Electrical
Issued 3 February 1990
Resolved
PROPERLY BRACE AND BAND LOOSE ELECTRICAL CABLES FOR STERN THRUSTER IN HOLD 7.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Fire Fighting
Issued 3 February 1990
Resolved
CROP OUT AND RENEW HOSE REEL FOR FIRE STATION NO. 107 IN FWD ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FOUNDATION BOLTS AND NUTS TO PUMP(UNLABELED) IN PORT AFT CORNER OF FWD ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPAIR OPEN-CLOSE INDICATOR TO FUEL OIL TRANSFER PORT SUCTION AND SETTLER STRIPPING VALVE IN FWD ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
CROP OUT AND RENEW FOUNDATION FOR FRESH WATER PUMP NEAR FIRE STATION 107 IN FWD ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FOUNDATION BOLTS AND NUTS ON DISTILLER PUMP IN FORWARD ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FOUNDATION INCLUDING BOLTS AND NUTS OF SUBMERSIBLE BILGE PUMP IN FORWARD ENGINE ROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FOUNDATION BOLTS AND NUTS TO NO. 1 AND NO. 2 BILGE PUMPS IN FORWARDENGINE ROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FOUNDATION BOLTS AND BOLTS TO AUXILIARY CONDENSATE PUMP INCLUDING DISCHARGE VALVE BOLTS AND NUTS IN FORWARD ENGINE ROOM
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REPLACE FOUNDATION BOLTS AND NUTS TO NO. 1 A/C CIRC PUMP IN FORWARD ENGINE ROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Accommodation/Occupational Safety
Issued 3 February 1990
Resolved
REMOVE ALL FLAMMABLE PIPING INSULATIONS, ESPECIALLY THIN BLACK INSULATION, IN ALL MACHINERY SPACES AND FAN ROOMS AND REPLACE AS NECESSARY WITH CG APPROVED TYPE NON-FLAMMABLE PIPE INSULATION.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Engineering
Issued 18 November 1989
Resolved
REBRICK #4 BOILER ROOF, SIDE, AND REAR WALL. REPAIR DETERIORATED SECTIONS OF CASTABLE REFRACTORY IN SUPERHEATER VESTIBULE INCLUDING LOWER HEMISPHERE OF STEAM DRUM IN REGION OF MISSING GENERATING TUBES. COMPLETE PRIOR TO RETURN TO HONOLULU FROM SHIPYARD.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
CONDUCT GENERAL SANITARY CLEAN UP OF CREW SPACES TO MINIMIZE POTENTIAL FIREHAZARDS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
REPLACE MISSING VENTILATION DUCT DIFFUSERS IN ALL "A" AND "B" DECK CREW ACCOMODATIONS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
REMOVE ALL HOUSEHOLD RECEPTACLE MULTIPLIERS AND HOUSEHOLD THIN GAGE EXTENSION CORDS FROM ALL CREW ACCOMODATIONS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Construction/Loadline
Issued 13 November 1989
Resolved
PROVIDE BOLTS FOR WATERTIGHT ACCESS HATCH COVER IN RESISTOR ROOM LEADING TO VOID SPACE BELOW.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989
Resolved
LABEL AND PROVE PROPER OPERATION OF FIRE DAMPERS FOUND INOPERABLE AND IDENTIFIED ON FIRE DAMPER INSPECTION REPORT.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Lifesaving
Issued 13 November 1989
Resolved
RENEW FOLLOWING DETERIORATED FORWARD AND AFT DAVIT ROLLER TRACKWAYS: LB #2 #3,#4,#6,#8,#9 & #11, ENTIRE LENGTHS; FOLLOWING LIMITED SECTIONS TO BE RE- NEWED: LB#1 FWD UPPER TRACK MIDLENGTH,#1 AFT LWR OUTBD END,#5 FWD&AFT LWR OUTBD ENDS,#10 AFT LWR OUTBD END, #12 FWD LWR OUTBD END.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Lifesaving
Issued 13 November 1989
Resolved
RENEW DETERIORATED DAVIT TRAVELING BLOCK CHEEK PLATES LB #6 FWD, #7 AFT, #9FWD & AFT, #11 FWD & AFT, #12 AFT.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Lifesaving
Issued 13 November 1989
Resolved
RENEW MISSING ROTTMER RELEASE RETAINING PIN LIFEBOAT#7 AFT, AND FREE UP ALLSTICKY PINS AS NEEDED ON ALL BOATS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Lifesaving
Issued 13 November 1989
Resolved
CONDUCT ANNUAL SERVICING OF LIFERAFT #5 WHICH IS DUE ON 16DEC89
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
REMOVE ALL COMBUSTIBLE LAMP SHADES, JAPANESE PAPER LANTERNS, UMBRELLAS, PLYWOOD BEDBOARDS, COMBUSTIBLE DRAPERIES, TRACK LIGHTS, AND CHRISTMAS LIGHTS FROM ALL CREW ACCOMODATIONS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
PROVIDE PROPER COVER PLATES FOR RECEPTACLE OUTLETS, CABIN LAMPS AND LIGHTING FIXTURES THROUGHOUT ALL "A" AND "B" DECK CREW ACCOMODATIONS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELL OUTSIDE CREW ROOM CB-58.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989
Resolved
PROVE PROPER OPERATION OF HEAT SENSORS AND FIRE TROUBLE ALARM IN ZONE 55
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989
Resolved
PROVE PROPER OPERATION OF ALL HEAT SENSORS IN ZONE 25, DINING ROOM.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989
Resolved
UPDATE KIDDE SMOKE DETECTION SYSTEM DIAGRAM IN THE FIRE CONTROL ROOM TO REFLECT CURRENT LAYOUT AND ZONE IDENTIFICATION
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989
Resolved
UPDATE VESSEL'S FIRE CONTROL PLAN TO PROVIDE ALL INFO REQUIRED BY 46 CFR 78.45-1 AND REFLECT VESSEL'S CURRENT CONDITION.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Construction/Loadline
Issued 13 November 1989
Resolved
REPAIR LEAKING HYDRAULICS ON WATERTIGHT DOORS #14 AND #19, AND REMOVE PAINTFROM DIRECTIONAL ARROW AT HYDRAULIC HAND PUMP ON WATERTIGHT DOOR #10.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
CLEAN EXCESSIVE GREASE BUILDUP ON GALLEY RANGES AND VENT HOODS
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
PROVIDE DECK DRAINS FOR GALLEY PANTRIES.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989
Resolved
CLEAN OUT GALLEY DECK DRAINS TROUGHS AND ASSOCIATED PIPING SYSTEM. PROVIDE EFFECTIVE DRAINAGE CAPABILITY FOR ENTIRE GALLEY SPACE.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Construction/Loadline
Issued 13 November 1989
Resolved
COMPLETE ALL INNER BOTTOM TANK TOP, AFT PEAK TANK TOP, AND DECK PLATE RENEWAL, MACHINERY FOUNDATION RENEWAL, AND COFFERDAM FUEL OIL CONTAMINATIONCLEAN UP AS SPECIFIED IN [name withheld] 16710/CONSTITUTION 71.50-3 OF 14NOV89 PRIOR TO RETURNING TO HONOLULU FROM SHIPYARD.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Construction/Loadline
Issued 11 November 1989
Resolved
CONDUCT GENERAL SANITARY CLEAN UP OF CREW SPACES TO MINIMIZE POTENTIAL FIRE HAZARDS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Fire Fighting
Issued 11 November 1989
Resolved
UPDATE KIDDE SMOKE DETECTION SYSTEM DIAGRAM IN THE FIRE CONTROL TO REFLECT CURRENT LAYOUT AND ZONE IDENTIFICATION.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Navigation
Issued 11 November 1989
Resolved
UPDATE VESSEL'S MAGNETIC COMPASS DEVIATION TABLE
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Navigation
Issued 11 November 1989
Resolved
PROVIDE RED LENS FOR RUDDER ANGLE INDICATOR ON BRIDGE.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Accommodation/Occupational Safety
Issued 11 November 1989
Resolved
RENEW DETERIORATED NON SKID SURFACE ON GALLEY DECK.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Accommodation/Occupational Safety
Issued 11 November 1989
Resolved
CONDUCT HYDROSTATIC TEST OF ALL PORTABLE OXYGEN CYLINDERS IN HOSPITAL SPACE WHICH HAVE PREVIOUS HYDRO TEST OF NOVEMBER 1984 OR EARLIER.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Accommodation/Occupational Safety
Issued 11 November 1989
Resolved
REPLACE DETERIORATED SPORTS DECK FAN ROOM SUPPLY FAN SCREENS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Construction/Loadline
Issued 11 November 1989
Resolved
RENEW RUBBER EXPANSION JOINTS AT FOLLOWING LOCATIONS: #4 MAIN CONDENSATE PUMP INTAKE, AFT MAIN CONDENSER LUBE OIL COOLER LOWER HEAT EXCHANGER UNIT, AND FWD MAIN CONDENSER DISCHARGE OUTLET.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Electrical
Issued 11 November 1989
Resolved
CLEAN BUSSES, CALIBRATE METERS, AND ADJUST VOLTAGE REGULATORS FOR FWD AND AFT MAIN SWITCHBOARDS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Engineering
Issued 11 November 1989
Resolved
REPACK EXCESSIVELY LEAKY #5 AUX CONDENSATE PUMP SHAFT GLAND.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Accommodation/Occupational Safety
Issued 11 November 1989
Resolved
REPACK EXCESSIVELY LEAKY #6C STBD AFT FAN ROOM A/C WARM WATER PUMP SHAFT GLAND.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Construction/Loadline
Issued 11 November 1989
Resolved
REPLACE GASKET AND MISSING DOGS FOR "B" DECK SIDE PORT DOORS AND HOSE TEST TO PROVE WATERTIGHTNESS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Construction/Loadline
Issued 11 November 1989
Resolved
REPLACE GASKET AND MISSSING DOGS FOR PORT AND STARBOARD SIDE FUELING STATION DOORS AND HOSE TEST TO PROVE WATERTIGHTNESS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Engineering
Issued 11 November 1989
Resolved
COMPLETE HYDRO TEST OF #4 BOILER PRIOR TO PLACING BOILER BACK ON LINE.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Engineering
Issued 11 November 1989
Resolved
ELIMINATE EXCESSIVE VIBRATION IN STERN THRUSTER ANGLE DRIVE UNIT AND KINETIC CONVERTER ASSEMBLY.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Engineering
Issued 11 November 1989
Resolved
ELIMINATE SEAWATER LEAKAGE AROUND STERN THRUSTER DIFFUSER VANE SHAFTS, AND HYDRAULIC FLUID LEAKS IN DIFFUSER HYDRAULIC CYLINDERS AND ASSOCIATED PIPINGSYSTEMS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Navigation
Issued 11 November 1989
Resolved
INVESTIGATE CAUSE AND MAKE PERMANENT REPAIR TO FRACTURED STEERING GEAR SIX WAY VALVE MOUNTING BRACKET ASSEMBLY.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Engineering
Issued 11 November 1989
Resolved
MAKE PERMANENT REPAIR TO ALL LEAKY SECTIONS OF FWD AND AFT ENGINE ROOM EXHAUST UPTAKES FROM BOILER EXHAUST PLENUMS TO STACK TOP HATS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Accommodation/Occupational Safety
Issued 11 November 1989
Resolved
PERMANENTLY REPAIR FWD AND AFT MACHINERY SPACE HOT WATER HEATER LEAKY SHELLASSEMBLYS.
Condition: Unknown
Due 11 November 1989
Resolved 11 November 1989
Construction/Loadline
Issued 26 August 1989
Resolved
CROP TO GOOD METAL AND REPLACE INNER BOTTOM TANK TOP PLATING UNDER BOILER #3 WITHIN THE MINIMUM PERIMETER SPECIFIED IN HANDWRITTEN REQUIREMENT OF 26 AUGUST 89; CROP TO GOOD METAL AND RENEW BOILER #3 FOUNDATION BED AND PEDES-TALS AND ASSOCIATED BRACKETS.
Condition: Unknown
Due 26 August 1989
Resolved 26 August 1989
Fire Fighting
Issued 4 August 1989
Resolved
PROMINENTLY IDENTIFY LOCATION OF FIRE STATION #39 PRESENTLY OBSCURED WHEN ADJACENT FIRE SCREEN DOOR IS IN OPEN POSITION
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Accommodation/Occupational Safety
Issued 4 August 1989
Resolved
DETERMINE IF FIRE DAMPER #61, CURRENTLY LISTED ON VESSEL'S SAFETY CHECK OFFBOOK, STILL EXISTS, AND IF SO LABEL AND PROVE OPERATION OF SAME.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Fire Fighting
Issued 4 August 1989
Resolved
PROVIDE IDENTIFICATION LABEL/STENCIL FOR FIRE STATION #54
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Construction/Loadline
Issued 4 August 1989
Resolved
CONDUCT PLATE THICKNESS GAUGING OF SPORTS DECK, AND MAIN DECK REGION IN VICINITY OF FANTAIL, AND SUBMIT RESULTS TO [name withheld]
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Engineering
Issued 4 August 1989
Resolved
REMOVE EXCESSIVE SOOT BUILDUP IN FWD AND AFT ENGINEROOM FIDLEYS
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Accommodation/Occupational Safety
Issued 4 August 1989
Resolved
ADJUST FWD ENGINEROOM "B" DECK ACCESS DOOR FOR TIGHT SEAL AND INSTALL MISSING HOSE CUT OUT HATCH PIECE
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Construction/Loadline
Issued 4 August 1989
Resolved
REINSTALL WATERTIGHT DOOR AT #2 HOLD UPPER TWEEN DECK STBD SIDE, AND ADJUSTSAME TO WATERTIGHT FIT
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Electrical
Issued 4 August 1989
Resolved
INSTALL EMERGENCY LIGHTING IN BOW THRUSTER AND STERN THRUSTER COMPARTMENTS
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Construction/Loadline
Issued 4 August 1989
Resolved
INSTALL OVERFLOW ALARM SENSORS FOR FUEL OIL OVERFLOW LINES BETWEEN FUEL OILSYSTEM AND #4 & #5 CL DEEP TANKS (MSD HOLDING TANKS); PENDING INSTALLATION OF SENSORS, PRIOR TO HOLDING TANK DISCHARGE MAKE VISUAL INSPECTION FOR OIL CONTAMINATION AND LOG SAME IN ENGINEER'S LOG.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Lifesaving
Issued 4 August 1989
Resolved
COMPLETE WORKLIST ITEMS FOR LIFEBOAT #1
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Fire Fighting
Issued 4 August 1989
Resolved
PROVE OPERATION OF FIRE SCREEN DOOR #8
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Lifesaving
Issued 4 August 1989
Resolved
COMPLETE WORKLIST ITEMS FOR LIFEBOAT #3
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Lifesaving
Issued 4 August 1989
Resolved
COMPLETE WORKLIST ITEMS FOR LIFEBOAT #5
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Fire Fighting
Issued 4 August 1989
Resolved
PROVIDE COPY OF EMS TECHNICIAN REPORT OF UPPER AND MAIN DECK FIRE DETECT- ION SYSTEM SERVICING CONDUCTED 3&4 AUG 89 AT NAWILIWILI
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Electrical
Issued 4 August 1989
Resolved
PROVE OPERATION OF SSTG#1 CIRCUIT BREAKER CONTROLLER
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Accommodation/Occupational Safety
Issued 4 August 1989
Resolved
PROMINENTLY LIST LOCATION OF THOSE FIRE DAMPERS LOCATED IN OBSCURED LOCATIONS SO AS TO PERMIT IDENTIFICATION FROM OUTSIDE COMPARTMENT; PROVIDE DIRECTIONAL ARROWS OR MARKINGS TO PERMIT PERSONS UNFAMILIAR WITH COMPART- MENT TO QUICKLY LOCATE DAMPERS.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Fire Fighting
Issued 4 August 1989
Resolved
PROVIDE IDENTIFICATION LABEL/STENCIL FOR FIRE ALARM BELL AT MAIN DECK STBD PASSAGEWAY AFT OF CREW LOUNGE
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Fire Fighting
Issued 4 August 1989
Resolved
PROVE OPERATION OF FIRE SCREEN DOOR #25 RELEASE MECHANISM
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Accommodation/Occupational Safety
Issued 4 August 1989
Resolved
ENCAPSULATE FLAKING ASBESTOS INSULATION LOCATED NEAR FIRE DAMPER BEHIND FIRE SCREEN DOOR #1
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Engineering
Issued 17 June 1989
Resolved
REPAIR MISSING REFRACTORY IN SUPERHEATER VESTIBULE, OVERHEAD AND SIDES, #2 BOILER.
Condition: Unknown
Due 17 June 1989
Resolved 17 June 1989
Engineering
Issued 17 June 1989
Resolved
MAKE PERMANENT REPAIRS TO LEAKING DESUPERHEATER TUBE IN WATER DRUM,#2 BOILER.
Condition: Unknown
Due 17 June 1989
Resolved 17 June 1989
Fire Fighting
Issued 29 April 1989
Resolved
INSTALL TIME DELAY FOR THE MACHINERY SPACE FIXED CO2 SYSTEM WHICH IS OF AN APPROVED TYPE WHICH WILL BE COMPATIBLE WITH THE EXISTING SYSTEM.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Accommodation/Occupational Safety
Issued 29 April 1989
Resolved
CEASE INSTALLATION OF THE AC UNIT ON THE UPPER DECK PORT SIDE IN CRIB STOREROOM FORWARD OF GYM. PRIOR TO COMMENCING ANY FURTHER WORK SUBMIT DRAWINGS TO THE [name withheld] AND APPROVAL. ONCE APPROVED WORK CAN CONTINUE BUT MUST BE TO SATISFACTION OF ATTENDING INSPECTOR.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Accommodation/Occupational Safety
Issued 15 April 1989
Resolved
PRIOR TO CONVERTING THE NO. 3 P & S CENTERLINE DEEP TANKS FROM FUEL TO MSD HOLDING TANKS, PROVIDE DETAIL DRAWING ON PIPING MODIFICATIONS TO COMPLETELYISOLATE TANKS FROM THE FUEL SYSTEM.
Condition: Unknown
Due 15 April 1989
Resolved 15 April 1989
Engineering
Issued 15 April 1989
Resolved
SUBMIT DRAWINGS ON FUEL PIPING SYSTEM TO SHOW MODIFICATIONS OF THE OVERFLOWLINES FOR THE AFT FUEL TANKS, I.E. SETTLERS, AND 3 PORT & STBD OUTBOARD DEEP FUEL TANKS.
Condition: Unknown
Due 15 April 1989
Resolved 15 April 1989
Accommodation/Occupational Safety
Issued 15 April 1989
Resolved
PROVIDE DETAILS, DRAWINGS, AND COMPLETED MODIFICATIONS TO COMPLETELY ISOLATE NO 4 & 5 CENTERLINE DEEP MSD HOLDING TANKS FROM THE FUEL SYSTEM, TOINCLUDE VENT, HEATING COILS, AND OVERFLOW PIPING. TANKS MAY NOT BE USED UNTIL THEY ARE COMPLETELY ISOLATED FROM THE FUEL SYSTEM.
Condition: Unknown
Due 15 April 1989
Resolved 15 April 1989
Engineering
Issued 8 April 1989
Resolved
REINSTALL OR REPAIR DAMAGED OR MISSING INSULATION ON PIPING SYSTEMS IN BOTHENGINE ROOMS WHERE SURFACE TEMPERATURE EXCEEDS 150 DEGREES F.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Electrical
Issued 8 April 1989
Resolved
INSTALL EMERGENCY LIGHTING IN THE FOLLOWING AREAS: STERN THRUSTER COMPT, BOW THRUSTER COMPT, AND HOLD SPACES IN VICINITY OF MSD UNITS AND HOLD ACCESS LADDERS.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Fire Fighting
Issued 8 April 1989
Resolved
HAVE ALL PORTABLE, SEMI-PORTABLE AND FIXED CO2 FIRE FIGHTING EQUIPMENT SERVICED AND A COPY OF THE SERVICING REPORT FORWARDED TO [name withheld] STATIONS, ALARMS AND VENTILATION SYSTEM SHUTDOWNS AND FLOW TEST CONDUCTED IN PRESENCE OF USCG INSPECTOR. REMOVE SPORTS DECK CO2 UNIT.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Lifesaving
Issued 8 April 1989
Resolved
CROP AND RENEW THE WASTED LOWER GUIDE PLATE ON THE FORWARD MAIN SHEAVE ON NO 8 LIFEBOAT FORWARD SHEAVE ASSEMBLY.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Lifesaving
Issued 8 April 1989
Resolved
COMPLETE ALL WORKLIST ITEMS FOR LIFEBOATS NO 8, 10 AND 12 EXCEPT ITEM COVERED BY CG-835 ITEM D2 CONCERNING FORWARD MAIN SHEAVE ASSEMBLY.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Accommodation/Occupational Safety
Issued 11 February 1989
Resolved
SUBMIT PROPOSAL TO THE [name withheld] WHERE COMBUSTIBLE FURNITURE AND FURNISHINGS HAVE BEEN INSTALLED IN SPACES OR AREAS DESIGNATED AS REQUIRING INCOMBUSTIBLE FURNITURE & FURNISHINGS AS INDICATED ON DRAWINGS 662-5, SHEETS 1-3.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
CONDUCT WEIGHT TEST IN PRESENCE OF A COAST GUARD INSPECTOR ON #4 LIFEBOAT.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Accommodation/Occupational Safety
Issued 11 February 1989
Resolved
CHANGE OUT ALL LOCKS ON CREWS CABINS WHICH DID NOT FIT THE MASTER KEY NOTEDDURING THE INSPECTIONS CONDUCTED 8 & 9 FEB89.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION TO THE KIDDE SMOKE DETECTION SYSTEM FOR ALL STATIONS. PROVIDE A FIRE WATCH TO MAKE A CHECK EACH HOUR OFALL SPACES PROTECTED BY THE SMOKE DETECTION SYSTEM UNTIL THE SYSTEM IS REPAIRED.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Construction/Loadline
Issued 11 February 1989
Resolved
REMOVE THE REFRIGERATION TEMPERATURE GAUGE FROM THE EQUALIZING PLUG TO THE BREAD AND JUICE REEFER BOX.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Navigation
Issued 11 February 1989
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE COURSE RECORDER.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE MANUFACTURER'S LABELS WITH COAST GUARD APPROVAL NUMBERS FOR BOTH LIFE FLOATS.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
TEST SAFETY VALVES IN #1 BOILER IN PRESENCE OF A COAST GUARD MARINE INSPECTOR TO ALLOW SET AND SEALING OF CRUM AND SUPERHEATER DRUM PILOT SAFETY VALVES.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
REBRICK FRONT, REAR, SIDE, ROOF AND FLOOR ON #3 BOILER.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
INSTALL DRIP PANS UNDER BOTH FUEL OIL TRANSFER PUMP STRAINERS.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Construction/Loadline
Issued 19 November 1988
Resolved
CROP AND RENEW THE WASTED TANK TOP AREA BELOW BOILER #1 USING CERTIFIED WELDERS PRIOR TO RENEWING BOILER FLOOR PLATE.
Condition: Unknown
Due 19 November 1988
Resolved 19 November 1988
Engineering
Issued 15 October 1988
Resolved
PROVIDE PROPER LUBE OIL PURIFIER BOWL FOR PURIFIER WITH BOWL PRESENTLY MISSING. VESSEL HAS TWO PURIFIERS AND ONLY ONE BOWL.
Condition: Unknown
Due 15 October 1988
Resolved 15 October 1988
Accommodation/Occupational Safety
Issued 15 October 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE SATISFACTORY OPERATION OF THE GALLEY COLD BOX CALL SYSTEM FOR ALARM BELL OPERATION ON THE RETURN MEAT BOX AND THE THAW BOX. PROPERLY MARK ALARM PANELS ON THE INDICATOR BOX IN GALLEY.
Condition: Unknown
Due 15 October 1988
Resolved 15 October 1988
Engineering
Issued 15 October 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE OILY WATER SEPARATOR.
Condition: Unknown
Due 15 October 1988
Resolved 15 October 1988
Construction/Loadline
Issued 15 October 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE SATISFACTORY OPERATION OF WATERTIGHT DOORS9B, 5C AND 1C.
Condition: Unknown
Due 15 October 1988
Resolved 15 October 1988
Accommodation/Occupational Safety
Issued 15 October 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE GENERAL ALARM BELL LOCATED IN THE VICINITY OF CABIN CC25.
Condition: Unknown
Due 15 October 1988
Resolved 15 October 1988
Fire Fighting
Issued 15 October 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE SATISFACTORY OPERATION OF FIRE SCREEN DOORS 34,29,25,23,35,30,26,24,18,17,12,2 AND 1 ON A-DECK; 17, 16 & 10 ON B-DECK; AND 17, 12, 9, 4, AND 3 ON C-DECK.
Condition: Unknown
Due 15 October 1988
Resolved 15 October 1988
Construction/Loadline
Issued 27 August 1988
Resolved
PROVIDE U.T. GAGING REPORT FOR ALL DOUBLE BOTTOM TANK TOPS.
Condition: Unknown
Due 27 August 1988
Resolved 27 August 1988
Construction/Loadline
Issued 8 August 1988
Resolved
EFFECT PERMANENT REPAIRS TO FLAT KEEL PLATE VIA TRANSITION METHOD FOR LAPPED-RIVETED JOINTS AS CALLED FOR IN NVIC 7-68 BETWEEN FRAMES 55 TO 60 IN WAY OF #3 DOUBLE BOTTOM.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Fire Fighting
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF HENSCHEL FIRE DETECTION SYSTEM FOR ZONE 52, & TROUBLE SWITCHES FOR ZONE 25 AND 54. CONTINUOUS FIREWATCH TO BE MAINTAINED UNTIL CORRECTED.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF ALL SENSORS FOR FIRE DETECTION ZONE 38. CONTINUOUS FIREWATCH TO BE MAINTAINED UNTIL CORRECTED.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Lifesaving
Issued 15 July 1988
Resolved
IN LIFEBOAT NO. 1 RENEW CRACKED SEAT FWD PORT SIDE, REWELD SAFETY CHAIN BRACKET AT EMBARKATION LADDER AND PROVIDE LANTERN.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Lifesaving
Issued 15 July 1988
Resolved
FOR NO. 3 LIFEBOAT, CROP AND RENEW WASTED SECTION OF THE FORWARD DAVIT ARM AFT ROLLER TRACK AND AFT DAVIT WASTED SECTION OF BOTH ROLLER TRACKS AND THEFWD LOWER SECTION OF THE TRACK FOOTING ON THE AFT TRACK.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Lifesaving
Issued 15 July 1988
Resolved
REMOUNT SWITCH PANEL IN NO. 3 LIFEBOAT.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF FIRE DETECTION SENSORS IN ZONE 7 AT ENGINEERS LOUNGE FORWARD PORT SIDE AND IN DECK LOUNGE FORWARD STBD SIDE AND AFT STBD SIDE. CONTINUOUS FIREWATCHES TO BE MAINTAINED UNTIL CORRECTED.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF RESET BUTTON FOR ZONE 16 AND FOR ZONE 27 SENSOR IN SERVICE LOCKER NO. 7, AND STEWARDS LOCKER NO. 3; AND FOR ZONE 56 AT CONFERENCE ROOM ENTRANCE STBD SIDE FOR FIRE DETECTION SYSTEM. CONTINUOUS FIREWATCHES TO BE MAINTAINED UNTIL CORRECTED.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Engineering
Issued 15 July 1988
Resolved
PRIOR TO OPERATION OF NUMBER TWO MAIN PROPULSION BOILER THE DRUM AND SUPERHEATER SAFETY VALVES ARE TO BE SET AND SEALED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Accommodation/Occupational Safety
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS TO ALL VENT GOOSE NECKS ON UPPER DECK FWD AND AFT.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF FIRE SCREEN DOOR 17.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 15 July 1988
Resolved
ADJUST OVERSPEED GOVERNOR AND RETEST OVERSPEED TRIP ON NUMBER TWO SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 15 July 1988
Resolved
FIND AND CORRECT GROUND FAULT IN SHIPS 117 VOLT ELECTRICAL SYSTEM.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 15 July 1988
Resolved
PROVIDE WIRING DIAGRAM IN ALL MOTOR CONTROLLER BOXES.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Engineering
Issued 15 July 1988
Resolved
PROVIDE INSTALLATION DATES OF ALL RUBBER EXPANSION JOINTS IN MACHINERY SPACES.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Construction/Loadline
Issued 15 July 1988
Resolved
AUDIO GAUGE TANK TOP FORWARD ENGINE ROOM FLOOR SPACES BELOW NUMBER ONE AND NUMBER TWO BOILERS. CROP AND RENEW THOSE AREAS WHICH EXCEED TWENTY-FIVE PERCENT WASTAGE (NO. 6 PORT INBOARD DOUBLE BOTTOM.)
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Construction/Loadline
Issued 15 July 1988
Resolved
CROP AND RENEW FRACTURED AREA (APPROXIMATELY SIX FEET LONG) TWO FEET IN FROM FRONT OF NUMBER ONE BOILER, PARALLEL TO FRONT (BURNER SIDE) OF BOILER (NO. 6 PORT INBOARD DOUBLE BOTTOM.)
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Documentation
Issued 15 July 1988
Resolved
OBTAIN ANNUAL LOAD LINE ENDORSEMENT AND SURVEY FROM THE AMERICAN BUREAU OF SHIPPING.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
INSTALL MAGNETIC HOLD BACK DEVICE AT FIRE SCREEN DOOR (FSD-2) MAIN DECK FORWARD.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Lifesaving
Issued 15 July 1988
Resolved
PROVIDE LANTERN FOR NO. 5 LIFEBOAT AND RENEW DISENGAGING APPARATUS RELEASE HANDLE.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF SENSORS FOR FIRE DETECTION ZONE 17 AT LINEN LOCKER NO. 1 & 2, SECURE LOCKER NO. 1 & 3, AND PUSH BUTTON BY CABIN 113. CONTINUOUS FIREWATCH TO BE MAINTAINED UNTIL CORRECTED.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Lifesaving
Issued 15 July 1988
Resolved
RENEW DETERIORATED SEATS FOR LIFEBOAT NO. 10.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Accommodation/Occupational Safety
Issued 15 July 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF FIRE DAMPERS 66, 81, AND 83.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Construction/Loadline
Issued 25 June 1988
Resolved
MAKE PERMANENT REPAIRS TO ENGINE TANK TOP INSERT/DOUBLER IN NO.7 INBOARD DOUBLE BOTTOM TANK BY CROPPING OUT EXISTNG REPAIRS INSERT AND WELD IN, GOUGE ROOT AND WELD BOTTOM SIDE. ALSO RENEW WASTED TOP 3 RUNGS FWD ACCESS LADDER.
Condition: Unknown
Due 25 June 1988
Resolved 25 June 1988
Construction/Loadline
Issued 25 June 1988
Resolved
INSTALL BLANKS AT ALL FILL AND SUCTION LINES TO ISOLATE NO.1,4,5 & 6 DEEP TANKS AND ALL DOUBLE BOTTOM TANKS AND OTHER LOCKED IN FRESH WATER BALLAST TANKS TO ISOLATE THEM FROM THE FUEL SYSTEM.
Condition: Unknown
Due 25 June 1988
Resolved 25 June 1988
Construction/Loadline
Issued 25 June 1988
Resolved
REMOVE NO.6 CENTER DEEP TANK FROM MSD HOLDING TANK SYSTEM AND PLACE IN LOCKED IN FRESH WATER BALLAST SYSTEM AS PER STABILITY BOOKLET.
Condition: Unknown
Due 25 June 1988
Resolved 25 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
OPEN, CLEAN, GAS FREE AND HAVE INSPECTED #6 PORT INBOARD, #7 PORT INBOARD AND #7 STBD INBOARD DOUBLE BOTTOMS AND THE AFT PEAK TANK.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
RENEW WASTED LADDER RINGS ON #2 PORT DOUBLE BOTTOM AFT MANHOLE ENTRANCE.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
PORT, STBD AND AFT COFFERDAMS IN LOWER #4 HOLD TANK TOP AREA TO BE DEWATERED AND CLEARED OF TRASH AND JUNK. THIS REQUIREMENT TO BE MET PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
EFFECT PERMANENT REPAIRS TO FLAT KEEL PLATE VIA TRANSITION METHOD FOR CAPPED-RIVITED JOINTS AS CALLED FOR IN NVIC 7-68 BETWEEN FRAMES 55 TO 60 IN WAY OF #3 DOUBLE BOTTOM.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
EFFECT PERMANENT REPAIRS TO PORT BOTTOM A AND B STRAKES, FRAMES 55-65, AT SET IN AREAS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
MAKE PERMANENT REPAIRS TO THE CHAIN LOCKER SUMP SOUNDING PIPE IN WAY OF RED HAND PATCH ADJACENT TO THE STBD CHAIN LOCKER MANHOLE COVER.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
VESSEL IS TO BE DRYDOCKED NOT LATER THAN 31 DEC 1989 IN ORDER THAT PERMANENT HULL REPAIRS BE COMPLETED AS CALLED FOR IN ITEMS 10, 11 AND 12.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
EFFECT PERMANENT REPAIRS TO STBD SIDESHELL C STRAKE BETWEEN FRAMES 46 TO 60 WHERE SET IN.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Electrical
Issued 4 June 1988
Resolved
AFFIX GLOBE GUARDS TO EXPOSED LIGHT BULBS ABOVE AND ADJACENT TO THE MSD'S AND IN THE ADJACENT REFRIGERATOR HOLD IN #4 CARGO HOLD. THIS REQUIREMENT TO BE MET PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Unknown
Issued 4 June 1988
Resolved
CLEAN DEBRIS, OLD BOARDS, TRASH, AND REFRIGERATOR DOORS FROM #4 LOWER CARGOHOLD. THIS REQUIREMENT TO BE MET PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
DEMONSTRATE DEWATERING OF BILGE WELLS IN THE FOLLOWING COMPARTMENTS VIA THEFIXED BILGE/BALLAST SYSTEM: #2 AND #3 REEFER CARGO HOLDS, #4 HOLD, #7 HOLDAND SHAFT ALLEY. THIS REQUIREMENT TO BE MET PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Lifesaving
Issued 4 June 1988
Resolved
LIFEBOAT DAVITS #1 AND #3 ARE TO BE WEIGHT TESTED. THIS REQUIREMENT TO BE MET PRIOR TO TAKING ON PASSENGERS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
EFFECT PERMANENT REPAIRS TO STARBOARD SIDESHELL C STRAKE BETWEEN FRAMES 45 AND 60 WHERE SET IN.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
VESSEL IS TO BE DRYDOCKED NO LATER THAN 31 DECEMBER 1989 IN ORDER THAT PERMANENT HULL REPAIRS ARE COMPLETED AS CALLED FOR IN ITEMS 10, 11 & 12.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
EFFECT PERMANENT REPAIRS TO FLAT KEEL PLATE VIA TRANSITION METHOD FOR LAPPED-RIVETED JOINTS AS CALLED FOR IN NVIC 7-68 BETWEEN FRAMES 55 AND 60 IN WAY OF #3 DOUBLE BOTTOMS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
EFFECT PERMANENT REPAIRS TO PORT BOTTOM A AND B STRAKES BETWEEN FRAMES 55 AND 60 AT SET IN AREAS.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 4 June 1988
Resolved
RENEW WASTED LADDER RUNGS ON #2 PORT DOUBLE BOTTOM AFT MANHOLE ENTRANCE.
Condition: Unknown
Due 4 June 1988
Resolved 4 June 1988
Construction/Loadline
Issued 16 April 1988
Resolved
CONDUCT UT GAUGING TO DETERMINE EXTENT OF TANKTOP WASTAGE IN WAY OF #8 PORTINBOARD DOUBLE BOTTOM TANK BETWEEN FLOORS 6 AND 7 FROM THE FORWARD END. REPAIR AS DIRECTED BY THE COGNIZANT OCMI.
Condition: Unknown
Due 16 April 1988
Resolved 16 April 1988
Construction/Loadline
Issued 16 April 1988
Resolved
CROP AND RENEW WASTED SECTIONS OF SOUNDING TUBE IN #8 STBD OUTBOARD DOUBLE BOTTOM TANK.
Condition: Unknown
Due 16 April 1988
Resolved 16 April 1988
Fire Fighting
Issued 9 April 1988
Resolved
REMOVE SANITARY LINE FROM FIRE MAIN IN FORWARD ENGINEROOM.
Condition: Unknown
Due 9 April 1988
Resolved 9 April 1988
Lifesaving
Issued 2 April 1988
Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF FLEMING GEAR FOR LIFEBOAT #8.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Lifesaving
Issued 2 April 1988
Resolved
CLEAN/RENEW AS REQUIRED BRAKE PADS AND OIL SEALS FOR THE CENTRIFUGAL BRAKESON LIFEBOAT WINCHES FOR BOATS #8 & 10. COMPLETE SURVEY ON ALL OTHER L/B WINCHES, REPAIR AS NECESSARY. PROVIDE REPORT ON FINDINGS & ACTION TAKEN.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Engineering
Issued 2 April 1988
Resolved
MAKE PERMANENT REPAIRS TO FUEL OIL LEAK IN FWD ENGINEROOM FWD BULKHEAD PORTSIDE.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Lifesaving
Issued 2 April 1988
Resolved
RENEW DETERIORATED SEATS ON LIFEBOATS #8,10 & 12. RENEW WASTED RELEASING GEAR MOUNTING BRACKET ON L/B #12. REPLACE MISSING BLOCK RETAINING PINS ASSEMBLY ON AFT BLOCK OF #8 L/B AND PROVIDE HYDROSTATIC RELEASE AND MFG STAMPS FOR LIFERAFTS #4 & 6.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Lifesaving
Issued 2 April 1988
Resolved
PROVIDE WATERTIGHT COVER FOR LINE THROWING GUN CONTAINER.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Construction/Loadline
Issued 2 April 1988
Resolved
REMOVE WOOD PLUGS IN THE TANK TOP PENETRATIONS IN 9 PORT OUTBOARD AND 9 STBD OUTBOARD AND MAKE PERMANENT WELD CLOSURES.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Fire Fighting
Issued 2 April 1988
Resolved
REMOVE PAINT FROM THE CO2 PERFORATED PIPING IN ALL 3 MACHINERY SPACES IN WAY OF THE DISCHARGE HOLES.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Fire Fighting
Issued 2 April 1988
Resolved
MAKE REPAIRS AND PROVE OPERATION OF HEAT DETECTOR SENSORS FOR ZONE 31 AND REPAIR RESET FOR ZONES 24, 40 & 52 ON MENSCHEL UNIT. VESSEL MUST MAINTAIN FIRE WATCH PATROL EVERY 30 MINUTES IN THESE ZONES UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Fire Fighting
Issued 2 April 1988
Resolved
RE-LABEL FIRE SCREEN DOORS 2 & 3 ON SUNDECK WITH PERMANENT LABELS AND REPAIR CLOSING DEVICE FOR FIRE SCREEN DOOR 13 ON B-DECK.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Fire Fighting
Issued 2 April 1988
Resolved
OPEN UP FOR INSPECTION FIRE DAMPER #28 LOCATED IN FAN ROOM 5A, B7-DECK.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Engineering
Issued 2 April 1988
Resolved
INSTALL 2 PROTECTIVE GUARDS OVER STERN THRUSTER SHAFT COUPLINGS.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Engineering
Issued 2 April 1988
Resolved
SURVEY ALL REMOTE PNEUMATIC AND HYDRAULIC VALVES AT STATION 1 & 2, REPAIR AND DEMONSTRATE OPERATION TO COAST GUARD INSPECTOR.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Electrical
Issued 26 March 1988
Resolved
REMOVE PAINT FROM FWD BOSUN HOLDS OR INSTALL EXPLOSIVE PROOF ELECTRICAL EQUIPMENT, SWITCHES, LIGHTING, ETC. AND EXTEND VENT DUCTING TO MAIN DECK.
Condition: Unknown
Due 26 March 1988
Resolved 26 March 1988
Construction/Loadline
Issued 19 March 1988
Resolved
PERMANENT REPAIRS MUST BE COMPLETED TO UPSET AREAS AND ALL AFFECTED STRUCTURAL MEMBERS IN DOUBLE BOTTOM TANKS 4 STBD, 5 STBD INBD, AND 6 STBD OUTBD.
Condition: Unknown
Due 19 March 1988
Resolved 19 March 1988
Construction/Loadline
Issued 19 March 1988
Resolved
NO. 6 STBD OUTBD DOUBLE BOTTOM TANK IS TO BE PUMPED, AND THE CONDITION OF THE TANK IS TO BE NOTED IN THE ENGINEERING LOG. THE TANK IS TO BE KEPT DRYTHE WEEK OF 21 MARCH FOR VISUAL INSPECTION AND HYDROSTATIC TESTING ON 26 MARCH 1988.
Condition: Unknown
Due 19 March 1988
Resolved 19 March 1988
Electrical
Issued 5 February 1988
Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS: (1) PORTSIDE IN THE MAIN GALLEY AND STENCIL; (2) IN WAY OF CABIN A317; (3) IN WAY OF W.T.D. #9A ON "A" DECK; AND (4) IN CARPENTERS SHOP AND STENCIL.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988
Resolved
REMOVE LIFEBOAT #2 TO SHORE IN ORDER TO INSPECT AND MAKE REPAIRS. REMOVE FLOORING AND PAINT SO THAT DETERIORATED PLATING AND RIVETS CAN BE INSPECTED. REPAIR AS DIRECTED INCLUDING A HOLE BY THE RIVETED SEAM JUST STARBOARD OF CENTERLINE AMIDSHIPS.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988
Resolved
REPAIR THE FRACTURED WELD ON LIFEBOAT #6 BETWEEN THE BOTTOM OF THE STERN TUBE AND THE KEEL PLATE.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Construction/Loadline
Issued 5 February 1988
Resolved
RENEW ROTTEN PLANKING AT THE WHEELHOUSE TOP STEERING STATION.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Construction/Loadline
Issued 5 February 1988
Resolved
PROPERLY SECURE THE MANHOLE COVERS IN THE FORWARD BOSUN STORES ON "B" DECK AND PROVIDE A CAP FOR THE SOUNDING TUBE OPENING.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988
Resolved
PROPERLY TENSION ALL LIFERAFT HYDROSTATIC RELEASES.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Electrical
Issued 5 February 1988
Resolved
REINSTALL CIRCUIT BREAKER COVERS AT ELECTRICAL STATION #31 IN THE GALLEY.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Accommodation/Occupational Safety
Issued 5 February 1988
Resolved
LABEL THE REFRIGERATION ALARM PANEL TO MATCH THE REFRIGERATION BOXES.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988
Resolved
PROVIDE A WATERLIGHT MOUNTING BRACKET FOR THE 2ND LIFE FLOAT.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Fire Fighting
Issued 5 February 1988
Resolved
REPAIR THE FOLLOWING FIRE STATIONS: (1) REPLACE NOZZLE TIP AT F/S #63 WITH NON-CLOGGING TYPE; (2) PROVIDE NOZZLE AND SPANNER AT F/S #73A, AND STENCIL ON THE FIRE CONTROL PLAN; (3) FREE UP NOZZLE BAIL AT F/S #83; (4) PROVIDE NOZZLE SPUD AT F/S #86.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988
Resolved
CORRECT LIFEBOAT DISCREPANCIES PER ISSUED WORKLIST.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Electrical
Issued 5 February 1988
Resolved
REPAIR AND PROVE THE OPERATION OF THE EMERGENCY GENERATOR ROOM'S FORWARD BULKHEAD VENTILATION LOUVERS.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Engineering
Issued 5 February 1988
Resolved
IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR, OPEN FOR INSPECTION BOILER #1 MOUNTINGS.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Engineering
Issued 5 February 1988
Resolved
IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR, OPEN FOR INSPECTION BOILER #3 MOUNTINGS.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Accommodation/Occupational Safety
Issued 5 February 1988
Resolved
CORRECT FIRE DAMPER AND VENTILATION DISCREPANCIES PER ISSUED WORKLIST.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Fire Fighting
Issued 5 February 1988
Resolved
CORRECT FOUR FIRE SCREEN DOOR DISCREPANCIES PER ISSUED WORKLIST.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Fire Fighting
Issued 5 February 1988
Resolved
INSTALL MAGNETIC HOLDBACK DEVICE FOR FIRE SCREEN DOOR #34 ON "A" DECK.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Construction/Loadline
Issued 5 February 1988
Resolved
RENEW GASKETS ON 2 SIDEPORTS (1 USED IN KONA, HI, AND ONE ON THE OPPOSITE SIDE OF THE VESSEL).
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Construction/Loadline
Issued 5 February 1988
Resolved
REPAIR AND PROVE WATERTIGHT THE FORWARD STBD FUELING SIDEPORT DOORS.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 5 February 1988
Resolved
CONDUCT WEIGHT TEST OF LIFEBOAT #4.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Unknown
Issued 28 October 1987
Resolved
IN THE PRESENCE OF A COAST GUARD INSPECTOR, HYDROSTATICALLY TEST ALL STEAM PIPING SUBJECT TO BOILER PRESSURE AND OF A NOMINAL DIAMETER OF 3 INCHES AND OVER. TEST PRESSURE TO BE 1 1/4 MAWP AND IS TO BE DONE AT NEXT DOCKSIDE AVAILABILITY.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Lifesaving
Issued 28 October 1987
Resolved
CORRECT THE MISALIGNMENT OF THE RELEASE ROD FOR THE ROTTMER GEAR IN LIFEBOAT #7. THE GEAR MUST BE ALIGNED IN A WAY WHICH PERMITS THE FORWARD AND AFTER FALLS TO RELEASE SIMULTANEOUSLY.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Unknown
Issued 21 October 1987
Resolved
OPEN FOR INSPECTION THE FORWARD ENGINEROOM D.C. HEATER.
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Unknown
Issued 21 October 1987
Resolved
OPEN FOR INSPECTION THE AFTER ENGINEROOM D.C. HEATER.
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Lifesaving
Issued 21 October 1987
Resolved
DRAIN, CLEAN AND RENEW ALL MOTOR LIFEBOAT DIESEL FUEL OIL TANKS WITH NEW FUEL OIL.
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Engineering
Issued 21 October 1987
Resolved
IN BOILER #1, REBRICK FRONT AND BACK WALLS, AND AS NECESSARY SIDEWALKL/ ROOF, BAFFLES AND FLOOR.
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Engineering
Issued 21 October 1987
Resolved
IN BOILER #4, REBRICK FRONT AND BACK WALLS, AND AS NECESSARY SIDEWALL/ ROOF, BAFFLES AND FLOOR.
Condition: Unknown
Due 21 October 1987
Resolved 21 October 1987
Unknown
Issued 30 June 1987
Resolved
HYDROSTATICALLY TEST ALL PORTABLE CO2 FIRE EXTINGUISHERS WITH A TEST DATE OVER 5 YEARS OLD.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR THE FOLLOWING LIFEBOAT EMBARKATION LIGHTS: LIFEBOAT #2, LIFEBOAT #5,LIFEBOAT #9.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR THE STARBOARD NAVIGATION LIGHT ALARM BUZZER ON THE CONTROL PANEL.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR THE WINCH COVER HINGES FOR LIFEBOAT #11.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR THE RELEASING GEAR HANDLE CONNECTING SLEEVE FOR LIFEBOAT #1.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE AFT ENGINE ROOM REMOTE VENTILATION SHUTDOWN.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE #1 BOILER FUEL OIL SOLENOID VALVE.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
PROVE PROPER OPERATION OF ZONE 35 IN THE FIRE DETECTION SYSTEM.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
PROVIDE A FLOAT FREE LINK FOR LIFERAFT #6.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
PROVIDE A FLOAT FREE LINK FOR LIFERAFT #8.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
RENEW OR SERVICE THE HYDROSTATIC RELEASE FOR LIFERAFT #4.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
REPAIR THE EMBARKATION LADDER FOR LIFEBOAT #11.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
RENEW THE FOLLOWING LIFEBOAT EMBARKATION LIGHT MOUNTING BRACKETS: LIFEBOAT #8, LIFEBOAT #11, LIFEBOAT #12.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
PROVIDE KEEPER DEVICES FOR THE RELEASING GEAR LINKAGE JOINT PINS FOR LIFEBOAT #1.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
PROVIDE 110 QUARTS OF WATER FOR LIFEBOAT #3.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
PROVIDE 234 QUARTS OF WATER FOR LIFEBOAT #5.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
RENEW THE DETERIORATED WOOD BENCHES AS MARKED IN LIFEBOAT #5.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
RENEW THE WINCH CONTROL SWITCH MOUNTING BRACKET FOR LIFEBOAT #5.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 15 April 1987
Resolved
REMOVE OR SEAL WELD SOIL LINE CLEANOUT PLUG LOCATED OVER SWITCHBOARD IN FORWARD ENGINE ROOM.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
RENEW BRASS CABLE GLAND IN WTBHD 128 OVER ENGINEROOM WTD #2 WITH APPROPRIATE SIZE, MATERIAL AND INSTALLATION.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
RENEW DATA PLATES ON ALL FOUR BLOWERS (MISSING).
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Engineering
Issued 11 April 1987
Resolved
REBRICK FRONT AND BACK WALLS OF THE FIRE BOX IN BOILER NO. 2.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Engineering
Issued 11 April 1987
Resolved
RETUBE MISSING AND PLUGGED TUBES IN WAY OF TUBES 6 - 15 LOCATED IN THE FIRST PASS OF THE SUPERHEATER IN BOILER NO. 2.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Electrical
Issued 11 April 1987
Resolved
RENEW EMERGENCY GENERATOR STARTING BATTERY BANK AND DEMONSTRATE PROPER OPERTION.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Engineering
Issued 11 April 1987
Resolved
UPON COMPLETION OF SUPERHEATER REPAIRS ON NO. 2 BOILER, HYDROSTATICALLY TEST THE BOILER TO 1-1/4 MAWP IN THE PRESENCE OF A COAST GUARD INSPECTOR. SET AND SEAL SAFETY VALVES.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Fire Fighting
Issued 11 April 1987
Resolved
INSTALL BREAK-GLASS HAMMERS AT FIRE CALL STATIONS 18 AND 26.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Documentation
Issued 11 April 1987
Resolved
PROVIDE A COPY OF THE WELDER QUALIFICATION CARD TO THE [name withheld] FOR THE WELDERS WHO ACCOMPLISHED THE REPAIRS TO THE BOILER NO.2 SUPERHEATER TUBES.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Accommodation/Occupational Safety
Issued 11 April 1987
Resolved
PROVIDE REGISTERED PROFESSIONAL ENGINEER STAMPED DRAWING OFTHE ASME AIR RECEIVER LOCATED IN THE PASSENGER EXERCISE ROOM FOR REVIEW BY A COAST GUARDINSPECTOR. MAKE RECEIVER AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Fire Fighting
Issued 11 April 1987
Resolved
REMOVE SANITARY CROSSOVER LINE FROM THE FIRE MAIN.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Electrical
Issued 11 April 1987
Resolved
TEST ALL SAFETY DEVICES ON THE EMERGENCY GENERATOR IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Navigation
Issued 11 April 1987
Resolved
INSTALL ALARMS IN STEERING SYSTEM AS REQUIRED BY 46 CFR 111.93-13 AND 46 CFR 113.43-3.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Engineering
Issued 11 April 1987
Resolved
IN THE PRESENCE OF A COAST GUARD INSPECTOR, HYDROSTATICALLY TEST ALL STEAM PIPING SUBJECT TO BOILER PRESSURE AND OF A NOMINAL DIAMETER OF 3 INCHES ANDOVER. TEST PRESSURE TO BE 1-1/4 MAWP AND IS TO BE DONE AT THE NEXT SCHEDULED DRYDOCK OR DOCKSIDE AVAILABILITY.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Electrical
Issued 11 April 1987
Resolved
REPLACE OR REPAIR THE FOLLOWING GENERAL ALARM BELLS: BETWEEN CAPT. AND CH. ENG. ROOM; P-51; MAIN GALLEY PORT AND STBD; CA14; CB13; CA58; B402; CC5; CC26; FWD ENG. ROOM B-FLAT; AFT ENGINE ROOM B-DECK.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Fire Fighting
Issued 11 April 1987
Resolved
PROVIDE NON-CLOGGING TIPS ON ALL FIRE STATION APPLICATORS.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Fire Fighting
Issued 11 April 1987
Resolved
INSTALL A 1-1/2 INCH FORE STATION ON THE 'A' DECK, PORT SIDE, AFT OF FIRE STATION 73. SUBMIT MODIFICATION TO FIRE CONTROL PLAN TO THE [name withheld].
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Engineering
Issued 11 April 1987
Resolved
ALL BOILER DRUM VENTS ARE TO HAVE TWO VALVES INSTALLED PRIOR TO VENTING AT ATMOSPHERE IN THE FIRE ROOM.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987
Unknown
Issued 23 February 1987
Resolved
RENEW TO ORIGINAL THE DEFORMED PLATE AT THE VESSELS BOW STEM BETWEEN DRAFT MARKS 24 AND 34 NOT LATER THAN THE COMPLETION OF THE VESSEL'S NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Unknown
Issued 4 February 1987
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED ROTOR ON #2 SHIP SERVICE TURBINE GENERATOR AND DEMONSTRATE PROPER OPERATION IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Unknown
Issued 27 January 1987
Resolved
REPLACE BELL ALARM FOR ALARM PANEL IN AFTER ENGINEROOM WITH THE SAME TYPE SIREN ALARM INSTALLED IN FORWARD ENGINEROOM.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Unknown
Issued 27 January 1987
Resolved
PLACE ON BOARD #4 LIFEBOAT 138 OUNCES OF EMERGENCY DRINKING WATER.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Unknown
Issued 27 January 1987
Resolved
DEMONSTRATE PROPER OPERATION OF #1 DRUM SAFETY VALVE ON #1 BOILER.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Unknown
Issued 27 January 1987
Resolved
MAKE PERMANENT REPAIRS TO BROKEN HANDLE FOR MAIN VENTILATION CIRCUIT BREAKER ON AFTER ENGINE ROOM MAIN SWITCHBOARD.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Construction/Loadline
Issued 12 December 1986
Resolved
CLEAN GASKETS TO PORT & STBD "B" DECK AFT (KONA) SIDEPORT
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
OPEN "A" DECK FWD & AFT/PORT & STBD CARGO SIDEPORTS FOR INSPECTION (4 TOTAL
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Deck/Cargo
Issued 12 December 1986
Resolved
ISTALL GUARDS OVER ELECTRICAL BREAKERS TO CARGO LIFTS IN WAY OF FORWARD & AFT "A" DECK SIDEPORTS.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Engineering
Issued 12 December 1986
Resolved
REPAIR CLOSURE INDICATOR ON STBD MAIN CONDENSER OVERBOARD VALVE LOCATED IN FORWARD ENGINEROOM
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Engineering
Issued 12 December 1986
Resolved
REPLACE EXPANSION JOINT TO CONDENSATE PUMP SUCTION LINE FORWARD ENGINEROOM(APPROX 18")
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
RENEW SEATING SURFACE, IN THE VALVE BODY, TO CLAPPER VALVES LOCATED IN THE FOLLOWING AREAS: 1. FWD ENGINEROOM BEHIND SWITCHBOARD (FWD) 2. #7 HOLD PORTFWD BULKHEAD 3. #7 HOLD PORT AFT BULKHEAD 4. #5 HOLD PORT FWD BULKHEAD 5. #5 HOLD MSD ROOM STBD.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
PROVIDE DECK GUAGING REPORT FOR THE FOLLOWING AREAS: 1. TWEEN DECK # 7 HOLD IN WAY OF OMNI-THRUSTER 2. # 5 HOLD IN WAY OF MSD ROOM 3. # 2 HOLD TWEEN DECK AFT IN WAY OF MSD
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
MAKE AVAILABLE #1 PORT & STBD AND #5 PORT DOUBLE BOTTOM BALLAST RTANKS FOR INSPECTION.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
PROVIDE GUAGING REPORT FOR HULL IN WAY OF THE WIND AND WATER STRAKE AND SEA CHESTS.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
RENEW GASKETS ON THE SIDEPORTS LOCATED IN THE FOLLOWING AREAS: A. PORT & STBD FORWARD FUELING STATION B. PORT & STBD "B" DECK CREW SIDEPORT C. PORT & STBD AFT FUELING STATION
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Construction/Loadline
Issued 12 December 1986
Resolved
PROVIDE PITTING REPORT FOR THE HULL FROM THE KEEL TO THE WIND AND WATER STRAKE
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Documentation
Issued 12 December 1986
Resolved
POST OIL TRANSFER PROCEDURES AT PORT FORWARD FUELING STATION
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Unknown
Issued 25 October 1986
Resolved
MAKE PERMANENT REPAIRS TO #7 PORT AND STARBOARD OUTBOARD DOUBLE BOTTOMS AT ROSE BOXES AND #7 PORT INBOARD DOUBLE BOTTOM WHERE AIR RECEIVER DRAIN LEAKSON TANK TOP.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Unknown
Issued 25 October 1986
Resolved
PROVE SATISFACTORY OPERATION OF AFT DRUM SAFETY VALVE ON #4 BOILER.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Unknown
Issued 25 October 1986
Resolved
MAKE REPAIRS TO THE SIDE SHELL VERTICAL FRAME, PORT SIDE, FORE PEAK TANK: FRAMES 1 & 2 FORWARD, SECOND DECK UP FROM THE BOTTOM OF THE VESSEL, AND THEFIRST FRAME FORWARD OF THE AFT BULKHEAD, SECOND DECK.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Unknown
Issued 25 October 1986
Resolved
MAKE PERMANENT REPAIRS TO PREVENT THE LEAKAGE OF STEAM INTO THE STEAM DRUM OF #4 BOILER FROM THE FOLLOWING 4 STEAM VALVES - THE AUXILIARY FEED STOP VALVE, THE AUXILIARY CHECK VALVE, THE MAIN FEED STOP VALVE AND THE MAIN CHECK VALVE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Unknown
Issued 21 August 1986
Resolved
SET AND SEAL NO. 3 BOILER SAFETY VALVES IN THE PRESENCE OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 21 August 1986
Resolved 21 August 1986
Unknown
Issued 21 August 1986
Resolved
REPAIR HEATING DRAIN RETURN LINE TO THE ATMOSPHERIC DRAIN TANK AT FRAME 128 IN FORWARD PART OF AFT ENGINE ROOM.
Condition: Unknown
Due 21 August 1986
Resolved 21 August 1986
Unknown
Issued 25 July 1986
Resolved
REMOVE PAINT FROM EXISTING WOODEN DECK MATTING OR PROVIDE APPROVED ELECTRICAL SAFETY MATTING FOR ALL SWITCHBOARDS.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Unknown
Issued 25 July 1986
Resolved
MAKE PERMANENT REPAIRS TO THE AFT ENGINE ROOM VENTILATION REMOTE STOP SWITCH AND DEMONSTRATE PROPER OPERATION IN THE PRESENCE OF THE COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Unknown
Issued 25 July 1986
Resolved
MAKE PERMANENT REPAIRS TO THE NO. 3 LIFEBOAT RADIO AND SEARCHLIGHT AND DEMONSTRATE PROPER OPERATION IN THE PRESENCE OF THE COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Unknown
Issued 25 July 1986
Resolved
MAKE PERMANENT REPAIRS TO THE NO. 3 AUXILIARY GENERATOR LOW LUBE OIL ALARM AND DEMONSTRATE PROPER OPERATION IN THE PRESENCE OF THE COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Unknown
Issued 25 July 1986
Resolved
OPEN ALL MOUNTINGS ON NO. 2 BOILER FOR INSPECTION BY THE COAST GUARD MARINEINSPECTOR.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Unknown
Issued 25 July 1986
Resolved
REPLACE ALL MISSING INCANDESCENT LIGHT GLOBES AND GUARDS IN THE ENGINE'S ROOMS, MACHINERY SPACE, AND SHAFT ALLEYS.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Unknown
Issued 16 April 1986
Resolved
REPAIR LEAKS IN PIPING AND PACKING ON REEL-TYPE FIRE HOSE STATIONS NO. 111 AND NO. 112 IN AFT ENGINE ROOM.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
OPEN BOILER MOUNTS ON #2 AND #4 BOILERS FOR FOUR YEAR INSPECTION.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
REPAIR WIPERS ON FORWARD BRIDGE WINDOWS.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
SERVICE FORWARD AND AFT ENGINE ROOM FIXED FIREFIGHTING CO2 LINES TO CLEAR CLOGGED DISCHARGE HOLES.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
REPAIR AND TEST FIXED CO2 SYSTEM IN SPORT DECK PAINT LOCKER.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
PROVIDE REPAIRS TO CARGO HANDLING EQUIPMENT AND TEST FOR CARGO GEAR CERTIFICATE.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
REPAIR STARBOARD CONDENSATE DISCHARGE PUMP CASING.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
PROVIDE APPROVED REPAIRS TO DETERIORATED PORTSIDE MIDSHIPS SECTION OF HULL ON LIFEBOAT NO. 7
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 14 March 1986
Resolved
PROVIDE APPROVED HATCHETS FOR LIFEBOATS 1 THROUGHH 12 IN ACCORDANCE WITH 46 CFR 160.013.
Condition: Unknown
Due 14 March 1986
Resolved 14 March 1986
Lifesaving
Issued 6 February 1986
Resolved
SUBMIT A REPAIR PROCEDURE IN ACCORDANCE WITH NAVIC 2-63 FOR OCMI'S REVIEW PRIOR TO MAKING PERMANENT REPAIRS TO THE LOOSE RIVETS LOCATED EXTERIOR PORT SIDE (MIDSHIP) OF LIFEBOAT NO. 12.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Lifesaving
Issued 6 February 1986
Resolved
PROVIDE APPROVED HATCHETS FOR LIFEBOATS 1 THROUGH 12 IN ACCORDANCE WITH 46 CFR 160.013.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Fire Fighting
Issued 6 February 1986
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING GENERAL ALARMS: ROOMS 262, 265, 104106, BETWEEN CH. ENG. AND MASTER'S ROOM, 313, 305, FIRE SCREEN DOOR 61, CA8STEWARD MESS, AFT OF WTD 9B, AFT OF WTD 19B, MAIN GALLEY PORT SIDE, HIBISCUS DINING ROOM.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Lifesaving
Issued 6 February 1986
Resolved
PROVIDE ONE QUART OF ILLUMINATING OIL FOR LIFEBOAT NO. 2.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Lifesaving
Issued 6 February 1986
Resolved
MAKE LIFEBOAT NO. 4 AVAILABLE FOR ANNUAL WEIGHT TEST.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Lifesaving
Issued 6 February 1986
Resolved
PROVIDE ONE QUART OF ILLUMINATING OIL FOR LIFEBOAT NO. 4.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Construction/Loadline
Issued 6 February 1986
Resolved
MAKE ROSE BOXES IN NO. 3 CARGO HOLD AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Construction/Loadline
Issued 6 February 1986
Resolved
MAKE ROSE BOXES IN NO. 2 CARGO HOLD AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Fire Fighting
Issued 6 February 1986
Resolved
REMOVE DEBRIS AND MAKE CO2 ROOM AVAILABLE FOR REINSPECTION.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Electrical
Issued 6 February 1986
Resolved
REMOVE TEMPORARY WIRING FROM NO. 3 HOLD (C DECK) STORE ROOM.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Unknown
Issued 11 January 1986
Resolved
PROVE REPAIRS TO CARGO WINCH BRAKE PRIOR TO USING CARGO GEAR.
Condition: Unknown
Due 11 January 1986
Resolved 11 January 1986
Construction/Loadline
Issued 21 December 1985
Resolved
SEWAGE SYSTEM VENT PIPING (PVC) INSTALLATION, WATERTIGHT BULKHEAD PENETRATIONS - SPOOL PIECES SHALL BE FITTED WITH AN ACCEPTABLE METALLIC SHUT-OFF VALVE ON EACH SIDE OF THE BULKHEAD OR THE VALVE SHALL BE OPERABLE FROM ABOVE THAT SPACE DECK.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Construction/Loadline
Issued 21 December 1985
Resolved
AFTER SEWAGE SPACE PORT SIDE, PVC PIPE PENETRATION WATERTIGHT BULKHEAD 198 SHALL BE FITTED WITH AN ACCEPTABLE SHUT-OFF VALVE.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Construction/Loadline
Issued 21 December 1985
Resolved
AFTER-PEAK PVC DRAIN PIPING SHALL BE FITTED WITH ACCEPTABLE SHUT-OFF VALVES.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Navigation
Issued 21 December 1985
Resolved
REMOVE SLACK FROM PORT AND STARBOARD STEERING GEAR FOLLOWUP LINKAGE AND PROVE SYSTEM.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Construction/Loadline
Issued 21 December 1985
Resolved
MAKE AVAILABLE ALL TANK TOPS, VOIDS, DOUBLE BOTTOMS, AND BALLAST TANKS FOR USCG EXAMINATION OF INTERNAL STRUCTURES. A SCHEDULE SHALL FIRST BE PROVIDED WITH TANK AVAILABILITY.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Construction/Loadline
Issued 21 December 1985
Resolved
PORT MAIN CONDENSER SCOOP OUTBOARD OF THE SEA VALVES, 12"X36" DOUBLER SHALL BE REMOVED. ALL DETERIORATED METAL SHALL BE CROPPED TO GOOD METAL ANDINSERTED TO THE MATING VALVE FLANGE AT NEXT DRYDOCKING.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Construction/Loadline
Issued 21 December 1985
Resolved
PORT MAIN CONDENSER DISCHARGE OUTBOARD OF THE SEA VALVE, 26"X36" DOUBLER, SHALL BE REMOVED. ALL DETERIORATED METAL SHALL BE CROPPED TO GOOD METAL AND INSERTED TO THE MATING VALVE FLANGE AT NEXT DRYDOCKING.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Construction/Loadline
Issued 21 December 1985
Resolved
PORT SIDE "J" STRAKE AFT OF BULKHEAD 86 TO JUST FORWARD OF FRAME 85 IS DETERIORATED AND SHELL PLATE 3'X8' SHALL BE CROPPED TO NEW PLATE AND INSERTED BY NEXT DRYDOCKING.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Engineering
Issued 21 December 1985
Resolved
PERMANENT REPAIRS SHALL BE MADE TO STARBOARD PROPELLER TAILSHAFT WITHIN THE AREA OF LINER AND SHAFT CORROSION, 23" FORWARD OF THE PROPELLER TAPER EXTENDING FORWARD APPROXIMATELY 31". ALL REPAIRS SHALL BE CG APPROVED. TEMPORARY REPAIRS SHALL BE REEXAMINED NOT LATER THAN JUL 86.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Lifesaving
Issued 21 December 1985
Resolved
LIFEBOAT DAVIT #11 WEIGHT TEST AT 110% MAXIMUM WORKING LOAD PRIOR TO THE INSTALLATION OF A LIFEBOAT.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Unknown
Issued 21 December 1985
Resolved
FORWARD STACK WASTED AQREAS AS MARKED SHALL BE REPAIRED. ALL INSULATION WHICH IS DETERIORATED, LOOSE AND MISSING SHALL BE RENEWED USING ONLY USCG APPROVED MATERIALS.
Condition: Unknown
Due 21 December 1985
Resolved 21 December 1985
Fire Fighting
Issued 11 November 1985
Resolved
PROVE PROPER OPERATION OF FORWARD ENGINE ROOM FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Engineering
Issued 11 November 1985
Resolved
REPAIR OR REPLACE ROOT VALVE FOR 1001BS STEAM REGULATOR.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Engineering
Issued 11 November 1985
Resolved
HYDRO NUMBER 4 BOILER MAIN STEAM LINE.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985
Resolved
MAKE PERMANENT REPAIR TO TWO CRACKS IN OVERHEAD OF FAN ROOM AFT OF STARLIGHT LOUNGE.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Accommodation/Occupational Safety
Issued 11 November 1985
Resolved
REPAIR AND TEST FRESH WATER LINE OVER FORWARD AFTER ENGINE ROOM WATERTIGHT DOOR.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Engineering
Issued 11 November 1985
Resolved
REPAIR OR REPLACE FORWARD ENGINE ROOM AIR EJECTOR BYPASS VALVE.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 17 August 1985
Resolved
A FIRE PATROLMAN WATCH MUST PHYSICALLY INSPECT ALL SPACES PROTECTED BY VESSEL'S SMOKE DETECTION SYSTEM ONCE EACH HOUR 24-HOURS A DAY. EACH PATROL IS TO BE OFFICIALLY LOGGED. PATROL TO BE MAINTAINED UNTIL SMOKE DETECTION SYSTEM IS SATISFACTORILY OPERATIVE.
Condition: Unknown
Due 17 August 1985
Resolved 17 August 1985
Engineering
Issued 2 August 1985
Resolved
PROVE NO. 2 AND 5 FEED PUMP OVERSPEED TRIPS.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Construction/Loadline
Issued 2 August 1985
Resolved
RENEW DECK COVERING WHERE CRACKED AND HOLED ON MAIN DECK FROM FRAME #10 AFT TO SUPERSTRUCTURE.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Construction/Loadline
Issued 2 August 1985
Resolved
RENEW DECK COVERING ON SPORT DECK WHERE CRACKED AND HOLED.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Accommodation/Occupational Safety
Issued 2 August 1985
Resolved
REPAIR OR REPLACE SALT WATER SUPPLY LINE (LOCATED IN AFTER STEERING SPACE) SERVING HOSPITAL TOILETS.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Accommodation/Occupational Safety
Issued 2 August 1985
Resolved
REPAIR OR REPLACE LAUNDRY ROOM VENT SUPPLY LINE.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Accommodation/Occupational Safety
Issued 2 August 1985
Resolved
REPAIR LEAKS IN MAIN GALLEY AND BAKERY GAYLORD HOOD SYSTEM.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Fire Fighting
Issued 2 August 1985
Resolved
REPAIR AND TEST THE KIDDE SMOKE DETECTING SYSTEM IN THE PRESENCE OF A COASTGUARD INSPECTOR. UNTIL SUCH TIME AS THIS ITEM IS SATISFIED, HOURLY FIRE PATROLS SHALL BE MADE IN THE PROTECTED SPACES.
Condition: Unknown
Due 2 August 1985
Resolved 2 August 1985
Lifesaving
Issued 29 July 1985
Resolved
MAKE PERMANENT REPAIRS TO LIFEBOAT NO. 11 AND ASSOCIATED DAVIT TO THE SATISFACTION OF THE [name withheld] TIME AS THIS ITEM IS CLEARED OWNER SHALL INSTALL AND MAINTAIN ABOARD VESSEL ADDITIONAL INFLAT- ABLE LIFERAFTS WITH CAPACITY FOR 150 PERSONS.
Condition: Unknown
Due 29 July 1985
Resolved 29 July 1985
Lifesaving
Issued 13 April 1985
Resolved
DEMONSTRATE/WEIGHT TEST EMBARCATION LADDERS FOR LIFEBOATS NO. 8, 10, AND 12
Condition: Unknown
Due 13 April 1985
Resolved 13 April 1985
Accommodation/Occupational Safety
Issued 13 April 1985
Resolved
PROVIDE PROTECTING FIXTURES OR REPLACE ALL EXPOSED INCANDESCENT LIGHT BULBSIN CREW DECK PASSAGES ON A, B, AND C DECKS.
Condition: Unknown
Due 13 April 1985
Resolved 13 April 1985
Deck/Cargo
Issued 13 April 1985
Resolved
REMOVE ALL DEBRIS, DISCONTINUED INSULATION, WOOD, ETC., FROM CARGO HOLDS NO. 3 AND NO. 4 ON OR BEFORE NEXT DRYDOCKING.
Condition: Unknown
Due 13 April 1985
Resolved 13 April 1985
Unknown
Issued 13 April 1985
Resolved
PROVIDE EVIDENCE OF ELEVATOR SERVICING/CONDITION FOR ALL VESSEL ELEVATORS.
Condition: Unknown
Due 13 April 1985
Resolved 13 April 1985
Lifesaving
Issued 1 February 1985
Resolved
MAKE PERMANENT REPAIRS TO FLEMMING GEAR IN NO. 9 LIFEBOAT.
Condition: Unknown
Due 1 February 1985
Resolved 1 February 1985
Lifesaving
Issued 1 February 1985
Resolved
PROVIDE A GUARD OVER THE EXHAUST PIPE FOR LIFEBOAT NO. 4.
Condition: Unknown
Due 1 February 1985
Resolved 1 February 1985
Electrical
Issued 1 February 1985
Resolved
DEMONSTRATE THAT THE EMERGENCY GENERATOR ENGINE WILL AUTOMATICALLY SHUT DOWN UPON LOSS OF LUBRICATING OIL PRESSURE AND UPON OPERATION OF THE FIXED CO2 SYSTEM PER 46 CFR 112.50-1(A).
Condition: Unknown
Due 1 February 1985
Resolved 1 February 1985