Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 June 2016
No resolution recorded
excesseive oil in bilge MDEs space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2016 — due date passed with no resolution recorded
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 June 2016
No resolution recorded
Remove Rule bilge pump piping from minfold. Needs to be directed overboard via shut off valve
Action required: 705 - Other - as specified
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 June 2016
No resolution recorded
port and stbd mufflers are holed and leaking
Action required: 705 - Other - as specified
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 14 June 2016
No resolution recorded
leaking cooliing water
Action required: 705 - Other - as specified
Engineering › Diesel Engine (auxiliary) › Gear, Timing
Issued 14 June 2016
No resolution recorded
install guard on rotating gears
Action required: 705 - Other - as specified
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 June 2016
No resolution recorded
stbd exhuast manifold missing bolts
Action required: 705 - Other - as specified
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 June 2016
No resolution recorded
bilge piping manifold missing valve handle
Action required: 705 - Other - as specified
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 June 2016
No resolution recorded
repair bilge manifold piping leaking water near seavalve
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2016
No resolution recorded
Remove bare wiring fwd of port MDE
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System › Piping
Issued 14 June 2016
No resolution recorded
wasted raw water through hull pipe port aft MDE space
Action required: 705 - Other - as specified
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 June 2016
No resolution recorded
Port MDE needs lagging insulation
Action required: 705 - Other - as specified
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 June 2016
No resolution recorded
MDEs space needs ventilation covers for the CO2 system
Action required: 705 - Other - as specified
Lifesaving › Lifefloat › Float-free Link
Issued 14 June 2016
No resolution recorded
lifefloats need weeklink
Action required: 705 - Other - as specified
Lifesaving › Visual Distress Signals (General) › Condition
Issued 14 June 2016
No resolution recorded
install required battery on light float
Action required: 705 - Other - as specified
Lifesaving › Lifefloat › Serviceable
Issued 14 June 2016
No resolution recorded
repair or replace 10 person lifefloat
Action required: 705 - Other - as specified
Lifesaving › Lifefloat › Paddle
Issued 14 June 2016
No resolution recorded
secure paddle in lifefloats
Action required: 705 - Other - as specified
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 June 2016
No resolution recorded
replace 15 condemmed lifejackets
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System › Pump
Issued 14 June 2016
No resolution recorded
secure bilge pump in the CO2 space
Action required: 705 - Other - as specified
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 June 2016
No resolution recorded
prove proper operation of bilge alarms
Action required: 705 - Other - as specified