Records from 2016 to 2025. Most recent: inspection, 16 April 2025.
Inspection history · 12
16 April 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8105348
25 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890730
21 March 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7658556
8 February 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7634219
28 February 2022
Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7401365
9 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7257997
17 June 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6992944
19 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6956247
26 March 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6644829
27 March 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6386205
27 March 2017
Hull Examination · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6100749
21 March 2016
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5837421
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 March 2024
Resolved
All flexible fuel lines designed for use with hose clamps must be installed with clamps at both ends of the hose. Main fuel lines only have one clamp on each end. Must rectify to the satisfaction of the USCG OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 5 April 2024
Resolution: Received pictures of added hose clamps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2024
Resolved
There must be enough approved life jackets for full passenger count and crew IAW the Certificate of Inspection. Vessel crew required to remove one (01) non approved life jacket by US regulations and one (01) life jacket that was in poor condition. Passenger count is reduced to fourteen (14) until rectified to the satisfaction of USCG OCMI.
Action required: 705 - Other - as specified
Resolved 8 April 2024
Resolution: Received pictures of new life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 9 March 2021
Resolved
The battery containment area was littered with several oily rags. Remove the oily rags and any oil build up.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 9 March 2021
Resolution: Rags were removed and containment area was cleaned.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 March 2021
Resolved
A light was out in the main cabin. Repair/replace the identified light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 9 March 2021
Resolution: Witnessed a satifactory test of the light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2021
Resolved
02 fire buckets were cracked. Replace the 02 cracked fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 9 March 2021
Resolution: Vessel acquired 02 new fire buckets with line and appropriate labeling.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2021
Resolved
Ring buoy light line was found unserviceable. Replace the light line on the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 9 March 2021
Resolution: Vessel acquired new light line for ring buoy.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2016
Resolved
Renew lens on starboard running light
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 5 April 2016
Resolution: Lens renewed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 March 2016
Resolved
Renew battery for life ring buoy light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 2 April 2016
Resolution: battery renewed
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 21 March 2016
Resolved
prove proper operation for the emergency light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 5 April 2016
Resolution: Emergency flashlight now working properly
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 March 2016
Resolved
provide burn cream for first aid kit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 22 April 2016
Documentation › Markings/Placards › Warning Signs
Issued 21 March 2016
Resolved
properly label emergency cut out valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 5 April 2016