11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 June 2026
Resolved
Each survival craft required on a vessel by this part must meet one of the following:
(1) For an inflatable liferaft—Approved under approval series 160.151 or other standard specified by the Commandant, with the applicable equipment pack, as determined by the cognizant [name withheld] liferafts were removed for servicing. Vessel is limited to no more than 1 nautical mile from shore.
Action required: 705 - Other - as specified
Resolved 17 June 2026
Resolution: O/o submitted photographs showing liferafts had been inspected and reinstalled properly.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 June 2026
No resolution recorded
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel did not have a valid Bridge-to-Bridge certification nor a valid Safety Radio Certification.
47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment,and electrical shock. MI discovered numerous openings/missing breakers in both electrial panels on board. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2025
Resolved 4 June 2026
Resolution: O/o covered openings with blanks
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 May 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Each rescue boat required in accordance with § 180.210 of this chapter must be launched with its assigned crew aboard and maneuvered in the water as if during an actual man overboard situation. Vessel is required to conduct a successful Man Overboard Drill, including the launching of the rescue boat, prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Conducted MOB drill
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 May 2025
Resolved
Vessel does not have any primary lifesaving devices onboard. Vessel is limited to one NM from shore until such devices are re-installed and inspected.
Action required: 705 - Other - as specified
Resolved 28 May 2025
Resolution: Vessel installed serviced liferafts.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 May 2025
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021. Distress signals onboard were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator provided new distress signals
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 May 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Generator did not secure when pre-engineered system activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator made satisfactory repairs to allow fixed system to shutdown generator
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel did not
have sails rigged for the inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Conducted inspection of rig while under sail.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2025
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. There was no working nozzle on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator provided new fire nozzle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2025
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. 02 panels in the engine room entry had open breaker holes and 01 breaker box cover was not attached to the housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator installed blanks in open slots of breaker panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2025
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge pick-up in foc'sle is missing strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator equipped vessel with new bilge strainer
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Waterlight failed to blink.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator provided a new waterlight
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 05 life jackets. Total persons on board is reduced to 125 until the missing lifejackets have been replaced and inspected.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator provided vessel with 5 more lifjackets
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2025
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles on board were made of plastic.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2025
Resolution: Operator provided new non-combustible trash receptacles
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 21 May 2025
Resolved
A vessel must be fitted with a general marine radar system for surface navigation if on Limited Coastwise Route. Vessel unable to test radar during inspection. To be tested during the full sail inspection.
Action required: 705 - Other - as specified
Resolved 4 June 2026
Resolution: Witnessed operation of the radar system.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 March 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection. Vessel must undergo an inspection for certification prior to operations.
46 CFR 176.500(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 September 2022
Resolved
All electrical equipment and circuits must be clearly marked and identified. One circuit breaker on the electrical panel was not clearly marked. Appropriately mark breaker.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 23 September 2022
Resolution: Circuit breaker was marked
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 September 2022
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Flexible electric cord was spliced in forecastle of ship to power anchor light. Make connection permanent or remove from service.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 23 September 2022
Resolution: Connection was made permanent
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging,blocks, fittings, and sails. Starboard side forward
chain plate on main mast is showing signs of wear.
Make piece available for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 23 September 2022
Resolution: Chain plate was removed, cleaned, and re-inspected. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2021
Resolved
Jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Inspected new lube oil gauge and jacket water temp gauge at operating station, sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021
Resolved
Written Maintenance Plan: All inspected sailing vessel owner/operators should have a written Preventive Maintenance Plan (PMP) that specifically addresses their vessel’s sail rigging equipment and components. See NVIC 02-16 for details on what the plan should include. Provide plan and proof of implementation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 30 September 2021
Resolution: Provided plan and proof of implementation.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 September 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. EPIRB should be listed as inspected, under the Radiotelephony Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 30 September 2021
Resolution: EPIRB listed as inspected, under the Radiotelephony Safety Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2021
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Bilge pump hose on discharge of PTO pump is not in serviceable condition. Replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Hose replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 September 2021
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Panel in engine room not enclosed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Inspected electrical panels, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2021
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Inspected flame arrestor sreens, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 September 2021
Resolved
Double hose clamping is required. Both generators fuel lines not hose clamped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Inspected generator fuel lines, sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Fuel leak on small generator poses a potential fire hazard. Make repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Inspected generator fuel piping for leaks,sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2021
Resolved
Vessel was granted extension for DD. Route is limited to lakes bays and sounds untill credit hull exam is completed. NLT 31OCT2021
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 19 October 2021
Resolution: Completed dry dock sat.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 9 September 2020
Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if: The vessel is self-propelled; The vessel has an oceans, coastwise, limited coastwise, or Great Lakes route. Radar installed but not operational. Provide operational radar. 705: vessel limited to Lakes Bays Sounds route only.
Action required: 705 - Other - as specified
Resolved 17 September 2020
Resolution: Faulty power wire identified and replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2020
Resolved
Each ladder used as a means of escape must be mounted at least 180 millimeters (7 inches) from the nearest permanent object in back of the ladder. Rungs
must be: (1) At least 405 millimeters (16 inches) in width; and (2) Not more than 305 millimeters (12 inches) apart, and uniformly spaced for the length of the ladder with at least 114 millimeters (4.5 inches) clearance above each rung. In vessels salon, rope escape ladder
provided is not suitable for use as a means of escape. Provide alternative ladder arrangement. 705: No passengers in the salon
Action required: 705 - Other - as specified
Resolved 17 September 2020
Resolution: Adequate escape ladder provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 September 2020
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less
than 610 millimeters (24 inches) in diameter. Ring buoy on operating station had frayed lifelines and its
body was worn beyond repair. Provide new ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 17 September 2020
Resolution: Life ring replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2020
Resolved
A bilge suction must be fitted with a suitable strainer
having an open area not less than three times the area
of the bilge pipe. In the forecastle the bilge piping
strainer has numerous wasted areas. Replace strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 17 September 2020
Resolution: Bilge strainer replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 9 September 2020
Resolved
The owner, charterer, master, or managing operator of
a vessel carrying overnight passengers shall have a
suitable number of watchmen patrol throughout the
vessel during the nighttime, whether or not the vessel
is underway, to guard against, and give alarm in case
of, a fire, man overboard, or other dangerous situation.
Vessel master stated that vessels crew did not comply
with the regulation while moored at the pier. Provide
written policy that implements this requirement.
705: no overnight passengers
Action required: 705 - Other - as specified
Resolved 17 September 2020
Resolution: Watchman/patrolman procedure developed and crew training on requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2020
Resolved
The generator circuit breakers must be interlocked to
prevent the generators from being simultaneously
connected to the switchboard. Interlock does not
prevent the shore power and “little generator” breakers
from being energized simultaneously. Provide a
interlock that prevents any two breakers from being
simultaneously energized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 17 September 2020
Resolution: Circuit breaker interlock replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2020
Resolved
A portable or temporary electric cord or cable must be
constructed and used in compliance with the
requirements of §111.60-13 in subchapter J of this
chapter for a flexible electric cord or cable. Air
conditioner in the stbd lazarette/crew area is powered
by an extension cord and plug strip. Remove
temporary wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 September 2020
Resolution: Temoprary wiring removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2020
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Cables
penetrating watertight bulkhead in the port lazarette liquor cabinet are not watertight. Make cable penetrations watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2020
Resolution: Wire penetrations sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2020
Resolved
U.S. Vessels, in commercial service, that are bound for ports or places within the navigable waters of the United States are required to submit a notice of arrival (NOA). LIBERTY CLIPPER did not submit a NOA IAW 33CFR160.212.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 March 2020
Resolved 25 March 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 October 2019
Resolved
Each officer employed on any vessel subject to this
subchapter must have his or her license or merchant
mariner credential onboard and available for
examination at all times when the vessel is operating.
Vessel master does not have his MMC onboard.
Provide MMC as required by regulation.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2019
Resolved 5 October 2019
Resolution: Master provided valid MMC
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
All wiring and cables shall be suitable for marine
service and for the particular installation used. Non
marine grade electrical cable is permanently installed
and powering multiple power receptacles in the vessel
overnight accommodations space forward of the salon.
Remove non marine grade cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 5 October 2019
Resolution: Cable replaced with proper marine grade cable.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 October 2019
Resolved
Suitable covers, guards, or rails shall be installed in
way of all exposed and hazardous places. Blades for
exhaust/supply fan in over head of engine space
vestibule are missing their guard. Provide guard for
fan blades.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 4 October 2019
Resolution: Metal guard installed over fan blades.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 3 October 2019
Resolved
Each overnight accommodation space on a vessel
with overnight accommodations for passengers must
be fitted with an independent modular smoke detection
and alarm unit that is UL217 approved. Port and stbd
aft most overnight accommodations spaces do not
have UL217 smoke detectors installed. Install smoke
detectors as required.
***Prior to carrying overnight pax
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 October 2019
Resolved 4 October 2019
Resolution: UL217 smoke detectors installed and verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Port aft most overnight accommodations space has
a light fixture mounted to the overhead that is powered
by a permanently installed extension cord. Remove
permanently installed extension cord.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 October 2019
Resolved 4 October 2019
Resolution: Extension cords removed. Permanent wiring installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Port aft most overnight accommodations space has
a red light fixture on ceiling missing lamp and terminal
covers. Provide lamp and terminal covers for light.
Action required: 705 - Other - as specified
Due 17 October 2019
Resolved 4 October 2019
Resolution: Covers provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Central accommodations space immediately
forward of the salon, inside cabin 6, has an electrical
connection box with exposed electrical terminals.
Connection box is at ground level stbd of the entrance
door behind the sink. Provide cover for connection
box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 4 October 2019
Resolution: Cover for connection box installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Central accommodations space immediately
forward of the salon, inside cabin 6, has a fan powered
by a permanently installed and spliced extension cord.
Remove permanently installed extension cord.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 October 2019
Resolved 4 October 2019
Resolution: Extension cord removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. A electrical cable splice outside of an enclosure
located Inside forward most accommodations space
along the upper edge of the stbd aft bulkhead. Make
electrical connections inside of an approved
enclosure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 October 2019
Resolved 4 October 2019
Resolution: Electrical box installed for connections.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Lights found hanging by wires in the salon along the
aft bulkhead amidships. Install lights as designed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 October 2019
Resolved 4 October 2019
Resolution: Lights mounted to surface as designed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Two box fans found powered by a permanently
installed extension cord in the salon overhead.
Remove permanently installed extension cord.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 4 October 2019
Resolution: Extension cords removed. Permanent wiring installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Dead ended electrical cable found on port side of
engine space vestibule. Remove dead ended cable or
insulate conductors and terminate inside of an
approved electrical enclosure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2019
Resolved 4 October 2019
Resolution: Electrical box installed and cable conductors properly insulated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2019
Resolved
Electrical installations and equipment shall be
maintained to result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Correct the following
discrepancy prior to carrying passengers overnight. Openings to live electrical components found
inside lower port side breaker panel inside the engine
space vestibule. Provide adequate covers for all
openings in breaker panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Covers installed over all openings for breaker panel.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 July 2019
Resolved
Openings in Watertight Bulkheads must have means to make them watertight.
MTWB between E/R and Captain's Qtrs has multiple areas where corrosion/wastage has holed the bulkhead.
Make written proposal for permanent repair to OCMI, and upon approval, complete work to satisfaction of attending [name withheld] must be satisfactorily completed prior to annual voyage south, and no later than 05OCT2019.
****In the interim, vessel is restricted to protected waters only, and no more than 1 NM from shore.****
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2019
Resolved 27 September 2019
Resolution: Repairs completed and tested sat. See Activity 6808106 for details.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 June 2019
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protection space. Automatic shutdown does not work.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2019
Resolution: Tested shutdown, sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 June 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 June 2019
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel does not have a valid FCC Station License
47 CFR 80.13
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 3 July 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: Updated charts and publications provided.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 17 June 2019
Resolved
EACH VESSEL THAT OPERATES ON THE HIGH SEAS, OR THAT OPERATES BEYOND THREE MILES FROM THE COASTLINE OF THE GREAT LAKES, MUST HAVE ON BOARD A FCC TYPE ACCEPTED CATEGORY 1, 406 MHZ EPIRB, INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE.
HYDROSTATIC RELEASE ON EPIRB IS EXPIRED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: Valid hydrostatic release provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 June 2019
Resolved
A HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT. CHAINLOCKER HATCH GASKET IS WASTED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: New gasket installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2019
Resolved
A PORTABLE OR TEMP ELECTRIC CORD MUST BE CONSTRUCTED AND USED IN COMPLIANCE WITH REQUIREMENTS OF 111.60-13 IN SUBCHAPTER J FOR A FLEXIBLE ELECTRIC CORD. LARGE NUMBER OF NON-COMPLIANT EXTENSION CORDS USED THROUGHOUT ACCOMODATION SPACES.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: EXTENSION CORDS REMOVED FROM VESSEL.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2019
Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, OTHER PERSONS, AND THE VESSEL FROM ELECTRICAL HAZARDS, INCLUDING FIRE, CAUSED BY OR ORIGINATING IN ELECTRICAL EQUIPMENT , AND ELECTRICAL SHOCK. LIGHT FIXTURE IN FWD COMPARTMENT DOES NOT HAVE A COVER, AND HAS EXPOSED WIRE SPLICES.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: LIGHT FIXTURE PROPERLY FITTED WITH A COVER, EXPOSED WIRES CONTAINED.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2019
Resolved
FOR PORTABLE FIRE EXTINGUISHERS... THE OWNER/MANAGING OPERATOR SHALL PROVIDE SATISFACTORY EVIDENCE OF THE REQUIRED SERVICING TO THE MARINE INSPECTOR. PORTABLE CO2 EXTINGUISHER IN STBD AMIDSHIPS COMPARTMENT HAS A WASTED HOSE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: A COMPLIANT EXTINGUISHER WAS PROVIDED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 June 2019
Resolved
A VOLTMETER, AMMETER, AND MEANS FOR MEASURING FREQUENCY SHALL BE PROVIDED FOR A GENERATOR THAT IS IN OPERATION. PROPER FUNCTIONING GAUGES NOT PROVIDED FOR EACH GENERATOR
46 CFR 183.10-5(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: GAUGES REPAIRED AND ARE OPERATING IN COMPLIANCE
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 June 2019
Resolved
ALL PIPING, VALVES, AND FITTINGS SHALL BE IN ACCORDANCE WITH GOOD MARINE PRACTICE AND SUITABLE FOR THE PURPOSE INTENDED. FIRE MAIN HAS AN UNAUTHORIZED TEMPORARY REPAIR IN THE PORT SIDE MACHINERY SPACE.
46 CFR 181.15-5 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: PERMANENT SATISFACTORY REPAIR MADE TO FIRE MAIN.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2019
Resolved
ALL VESSELS OF 26 FEET IN LENGTH AND OVER SHALL BE PROVIDED WITH INDIVIDUAL BILGE LINES AND BILGE SUCTIONS FOR EACH WATERTIGHT COMPARTMENT. BILGE SUCTION ARRANGEMENT UNDER THE CAPTAINS QUARTERS DOES NOT MEET THE REQUIREMENTS OF 46 CFR 182.25-5(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 3 July 2019
Resolution: BILGE SUCTION TESTED SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2019
Resolved
AN ADULT LIFE JACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD A VESSEL.
VESSEL IS RESTRICTED TO CARRYING 127 PASSENGERS, INCLUDING CREW, UNTIL ADDITIONAL LIFE JACKETS ARE PROVIDED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 18 June 2019
Resolution: PROVIDED 03 ADDITIONAL LIFE JACKETS TO MEET REQUIREMENTS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2019
Resolved
THE COGNIZANT OCMI MAY REQUIRE THAT A VESSEL AND ITS EQUIPMENT UNDERGO ANY ADDITIONAL TEST OR INSPECTION DEEMED REASONABLE AND NECESSARY TO DETERMINE THAT THE VESSEL AND ITS EQUIPMENT ARE SUITABLE FOR THE SERVICE IN WHICH THEY ARE TO BE EMPLOYED.
CONDITIONS OF STANDING RIGGING NOTED DURING ANNUAL INSPECTION ON 26SEP2017 WHICH WERE INDICATED BY MASTER TO HAVE BEEN IDENTIFIED FOR RENEWAL DURING 2018 DRYDOCK, HAVE NOT BEEN ADDRESSED. ITEMS DURING 2017 INSPECTION NOTED AS FOLLOWS:
(1) Foremast starboard mid shroud has a bottomed-out turnbuckle
(2) Lower main mast port/stbd fore shrouds: wire rope eyes slightly "bird caged" in thimbles IWO turnbuckles
(3) Upper main mast stbd shroud: shackle connection to chain plate has improperly sized pin and turnbuckle is bowed.
(4) Main sheet traveler end gussets corroded to about 50% of 1" original thickness.
IN ADDITION, DURING CURRENT ANNUAL INSPECTION, MAIN TOPMAST SHROUD CHAINPLATE ON P/S WAS OBSERVED TO BE DEPLETED FROM CORROSION, AND TWISTED/DEFORMED.
SUBMIT WRITTEN PLAN WITH TIMELINE TO SECTOR BOSTON TO ADDRESS THESE ISSUES AND ENSURE OVERALL INTEGRITY OF RIG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 1 August 2019
Resolution: Revised action plan submitted.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 June 2018
Resolved
Prove proper operation of pre-engineered fire extinguishing system. Ensure automatic shutdown of generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2018
Resolved 28 June 2018
Resolution: Tested auto shutdown of all machinery in engineroom. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2018
Resolved
Properly mark and affix retro-relective tape on stbd ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2018
Resolved 23 July 2018
Resolution: Retro-relective tape properly installed on life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2018
Resolved
Provide functional lights on 03 life preservers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2018
Resolved 23 July 2018
Resolution: New lifepreserver lights purchased and tested sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 June 2018
Resolved
Make penetrations in aft bulkhead of forecastle, stbd side, watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2018
Resolved 23 July 2018
Resolution: Penetrations in aft bulkhead of forecastle sealed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 June 2018
Resolved
Make proper connections/terminations of emergency lighting conductor stbd midships.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2018
Resolved 23 July 2018
Resolution: Conductors for emergency lighting stbd midships properly insulated and repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 September 2017
Resolved
Two fire extinguishers found inoperable in Forecastle (dry chem - discharged) and Nav Shack (CO2 - hose worn/cracked). Provide 02 fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2017
Resolved 28 September 2017
Resolution: Replaced extinguisher.
Electrical › Lighting (service) › Switch
Issued 26 September 2017
Resolved
Mount light switch in receptacle in forward compartment
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Light switch circuit was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 September 2017
Resolved
Place spliced electrical wires in j-box with cover in port midships compartment.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: wires were placed in a junction box.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 September 2017
Resolved
Replace/repair distribution panel cover in port midships compartment
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Panel cover was repaired.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 September 2017
Resolved
Make all engines that draw air from within space capable of shut down with Fireboy activation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 28 September 2017
Resolution: Vessel rep ensured generator shutdown with fireboy activation.
Lifesaving › Lifebuoys › Serviceable
Issued 2 June 2017
Resolved
Grabline was wasted. Vsl had three other serviceable RLBs. Renew/remove from vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: Master removed RLB from vsl.
Communications › Radio Communications › EPIRB
Issued 2 June 2017
Resolved
EPIRB NOAA registration was expired. Vsl restricted to <3 NM from shore. Also required to mark date on hydrostatic release.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 19 June 2017
Resolution: Vsl operator installed new EPIRB hydrostatic release unit with expiration of June 2019.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 September 2016
Resolved
Prove proper operation of pre-engineered system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2016
Resolution: Tested shutdown of pre-engineered system and bypass. All sat.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 26 September 2016
Resolved
Provide 02 liferafts. VSL restricted to 03 miles from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 30 September 2016
Resolution: Two 25 Person ILRs were installed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 September 2016
Resolved
Replace EPIRB battery. VSL restricted to 03 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 30 September 2016
Resolution: Battery was replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 26 September 2016
Resolved
Install retro reflective tape on 02 lifebouys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 30 September 2016
Resolution: Retro reflective tape installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 September 2016
Resolved
Replace STBD midships #3 fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 30 September 2016
Resolution: Extinguisher was replaced.