Inspection history · 70
10 November 2022
PSC B · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7591178
18 May 2022
PSC B · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7450433
30 August 2021
CCSSC Examination · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7300087
16 February 2021
CCSSC Examination · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7141096
7 August 2020
PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7025751
4 August 2020
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7023902
3 July 2020
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6990259
18 March 2020
PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6928401
14 August 2019
ISPS III Exam · CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6781461
30 April 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6671746
9 January 2019
CCSSC Examination · PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6606424
15 July 2018
PII Safety Exam · CCSSC Examination · Deficiency Check · Administrative Inspection · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6503272
9 January 2018
CCSSC Examination · MTSA Verification · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6333187
15 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6241336
3 August 2017
CCSSC Examination · NPV Safety Exam · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6229227
1 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6227077
6 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6167057
19 May 2017
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6150002
8 May 2017
MTSA Verification · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6139612
8 November 2016
CCSSC Examination · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6037266
16 March 2016
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5834554
10 March 2016
Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5830936
23 February 2016
CCSSC Examination · NPV Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5820387
16 September 2015
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5720527
24 August 2015
ISPS III Exam · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5221346
24 February 2015
CCSSC Examination · PII Safety Exam · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5071467
18 December 2014
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5039103
14 October 2014
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5004592
23 August 2014
MTSA Verification · PII Safety Exam · Deficiency Check · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4963056
4 March 2014
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4809910
22 February 2014
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4803831
21 February 2014
CCSSC Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4803199
1 January 2014
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4780716
10 October 2013
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4732488
21 August 2013
ISPS II Exam · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4692248
21 June 2013
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4626997
20 May 2013
CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4594992
29 January 2013
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4524530
18 January 2013
ISPS III Exam · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4518315
1 January 2013
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4509036
9 November 2012
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4478446
12 October 2012
PI Safety Exam · CCSSC Examination · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4460925
12 October 2012
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4521186
10 September 2012
PII Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4436898
10 September 2012
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4437467
8 June 2012
CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4336578
15 December 2011
CCSSC Examination · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4208685
21 September 2011
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4150953
15 September 2011
CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4145701
31 January 2011
CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 3936199
29 July 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3808109
28 November 2008
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3370465
28 November 2008
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3371719
5 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2617601
20 February 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2588732
12 October 2005
Administrative Inspection · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2512839
17 June 2005
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2393421
19 May 2005
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2362247
26 April 2005
Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2343472
18 October 2004
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2223364
7 July 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2125168
14 June 2004
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2098132
9 February 2004
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2003083
21 May 2003
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1798313
27 March 2003
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1763633
27 March 2003
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1763710
24 March 2003
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1761060
10 May 2002
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1616643
5 May 2002
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1612925
10 April 2002
Security Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1603093
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2022
Resolved
07110 - Fire fighting equipment and appliance - Every ship should be provided with a minimum of 02 fire hoses. One of the ships fire hoses was no longer serviceable. 97 CCSSC 3.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Vessel provided objective evidence to satisfy the deficiency. Vessel acquired a serviceable fire hose to replace the non serviceable fire hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2022
Resolved
11117 - Lifebuoys including provision and disposition - Lifebuoys should be marked with the name and port of registry of the ship on which it is carried. 97 CCSSC 4.12.5.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 May 2022
Resolution: Vessel Marked lifebuoy in accordance with the requirements of the code.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 30 August 2021
Resolved
The administration should provide every such ship with an appropriate safe manning document as evidence of minimum safe manning necessary to satisfy the provisions of 1.7.1
CCSSC 1.7.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2021
Resolution: Certificte sent to USCG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 August 2021
Resolved
The conditions of the ship and its equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board or the environment. Yanmar aux generator is inoperable.
CCSSC 1.11.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2021
Resolution: Verified proper operation of Aux Gen.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2021
Resolved
Every fire hose should be provided with an approved nozzle and the necessary couplings. Starboard side firehose missing nozzle.
CCSSC 3.5.9
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2021
Resolution: Vesel purchased nozzels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2020
Resolved
All machinary, mechanical equiptment and associated piping systems should be of a design and construction adequate for the service for which they are intended and should be so installed and protected as to reduce to a minumu any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Soft patches exist on the bildge pump piping as well as on the engine cooling system which is not in accordance with adequate construction for service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2020
Resolved 4 August 2020
Resolution: Verified satisfactory repairs to soft patches.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 January 2019
Resolved
Emergency fire pump shall be permentantly affixed. Vessel currently has portable fire pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2019
Resolved 18 March 2020
Resolution: Deficiency Rectified. Tested emergency fire pump.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 July 2018
Resolved
0750 - Stairways and ladders should be arranged tp provide accommodation spaces ready means of escape to the open deck and thence to the survival craft. Emergency escape leading from crew accommodation space is inoperable - CCSSC (1997) 3.16.4.1 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2018
Resolved 17 July 2018
Resolution: MSD ST Thomas received email with pictures attesting the proper operation of emergency escape.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2018
Resolved
0730 - The condition of the ship and its equipment is maintained to conform with the code and will proceed to sea without danger to the ship and persons on board. Fire hydrant located on port bow is missing control handle - CCSSC (1997) 1.11.1 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2018
Resolved 17 July 2018
Resolution: MSD ST Thomas received email with pictures attesting the newly installed hydrant control handle.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 3 August 2017
Resolved
1410 - Means shall be provided whereby normal operations of machinery can be sustained. During course of examination engineer was unable to start port side main engine. PSCO witnessed arcing at starter motor lug. - CCSSC (1997) 2.35.2.1 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2017
Resolved 15 August 2017
Resolution: Vessel repaired starting arrangements and replaced exhaust manifold and after cooler. MI witnessed satisfactory starting and operation of engine.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 3 August 2017
Resolved
0230 - The administration shall provide each such ship with an appropriate safe manning document as evidence of the minimum safe manning considered necessary to satisfy the provisions of 1.7.1. Minimum safe manning document requires 01 engine rating watch or able seafarer engine with STCW III/4 or III/5. Vessel was not manned with a crewmember holding STCW III/4 or III/5. - CCSSC(97) 1.7.2 - 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2017
Resolved 15 August 2017
Resolution: Vessel replaced one of the deck crew with and engine rating watch.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 May 2017
Resolved
The position of the rudder shall be indicated on the bridge. The rudder angle indicator is currently not working. CCSS Code (1997)Chapter 2.38.8. Action 17.c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2017
Resolution: Rudder angle indicator operating properly
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 May 2017
Resolved
In all ships, fire control plans should be kept up to date. The fire control plan on board is not accurate. CCSS Code (1997)Chapter 3.13.2 Action 50.a.c
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 16 June 2017
Resolution: Updated fireplan posted.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 8 May 2017
Resolved
Every ship shall be provided with at least two anchors provided with a chain cable of adequate strength and size. Port side chain cable links are twisted and elongated. Whelps on port and starboard wildcats are wasted. CCSS Code (1997)Chapter 2.9.1. Action 50.a.c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 16 June 2017
Resolution: Wasted anchor chain and shackles replaced. Winch whelps renewed.
Deck/Cargo › Towing › Towline
Issued 8 May 2017
Resolved
The towing and mooring arrangements shall be of adequate strength and suitable for the particular type of barge. Several chain cable links on the die lock chain are elongated and missing. CCSS Code (1997)Chapter 2.11.2 Action 16.c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 9 May 2017
Resolution: Wasted links were removed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 8 May 2017
Resolved
The strength and construction of other structures and equipment should be sufficient to withstand all foreseeable conditions of the intended service. The current sewage holding tank is corroded and has multiple holes leaking into the bilge. CCSS Code (1997)Chapter 2.4.1 Action 50.a.c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 16 June 2017
Resolution: New type II MSD Installed to satisfaction of class.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 May 2017
Resolved
At least half of the number of lifebuoys shall be fitted with self-igniting lights with technical specifications as outlined in the LSA Code. The batteries for the self-igniting lights have expired. CCSS Code (1997)Chapter 4.12.2 Action 40.c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 May 2017
Resolution: New batteries were purchased and installed in the self-igniting lights.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 May 2017
Resolved
Electrical installations should be such that the safety of personnel and ship from electrical hazards will be assured. The electrical outlets in the berthing area were overloaded and multiple daisy chains were observed. CCSS Code (1997)Chapter 2.31.1.3 Action 16.a.c
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 16 June 2017
Resolution: Daisy chains removed.
Engineering › Fuel Oil Service System › Filter
Issued 8 May 2017
Resolved
Pipes, fittings, and valves handling fuel oil should be of the steel or other approved material. The current fuel filters are missing the manufacturer's flame bowl. CCSS Code (1997)Chapter 3.19.6 Action 16.c
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Resolution: Flame bowls were placed on all glass fuel filters.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2015
Resolved
Moving parts of machinery which are so exposed as to cause accidents should be properly guarded. Starboard diesel generator missing guard over belts. CCSSC 2.12.6 16(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 16 September 2015
Resolution: Guard has been placed over belts of starboard diesel generator
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 August 2014
Resolved
1410- Condition of ship and its equipment will remain fit to proceed to sea without danger to ship, persons onboard or the environment. Starboard engine jacket water pipe ruptured. CCSSC Code Ch. 1.11.1. 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2014
Resolved 26 August 2014
Resolution: Vessel crew replaced ruptured pipe.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 23 August 2014
Resolved
1320 - Every ship should be provided with at least two anchors of which is provided with a chain cable of adequate strength and size and windlass. Vessels anchor windlass is inoperable. CCSSC Code CH. 2.9
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 18 December 2014
Resolution: Work repairs completed in bow area anchor winch
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 February 2014
Resolved
At least half the number of lifebuoys should be fitted with a self igniting light. Light on the aft bridge bulkhead does not turn on
Action required: 705 - Other - as specified
Due 7 March 2014
Resolved 4 March 2014
Resolution: Vessels agent provided evidence (video) of kight in operational status and receipt for the purchase of a battery for the light.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 21 February 2014
Resolved
Each vessel must have an echo depth sounding device. Vessels echo depth finder has a short and is not functioning
Action required: 17 - Rectify deficiencies prior to departure
Due 21 February 2014
Resolved 21 February 2014
Resolution: Tech came on board and got echo depth sounder functioning.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 21 August 2013
Resolved
0650-STBD lifebuoy line is wasted- CCSSC 4.12.4
Condition: Improper/Lack of Maintenance
Due 28 August 2013
Resolved 10 October 2013
Resolution: Attending Marine Inspector witnessed satisfactory new lifebuoy line.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 August 2013
Resolved
1560 - VSL does not have up to date charts (corrected), chart correction log or notice to mariners - CCSSC 6.2
Due 28 August 2013
Resolved 10 October 2013
Resolution: Attending marine Inspector wittnessed satisfactory corrections to charts, chart correction log and notice to mariners.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 August 2013
Resolved
1570 - VSL does not have up to date nautical publications on board. - CCSSC 6.2
Due 28 August 2013
Resolved 10 October 2013
Resolution: Attending marine Inspector witnessed satisfactory new nautical publications.
Engineering › Lubricating Oil Service System › Pump
Issued 20 May 2013
Resolved
Vessels has excessive fuel leak coming from fuel injector pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2013
Resolution: Received tech report and Flag statement attesting to the replacement of fuel injector pump.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 20 May 2013
Resolved
Vessels rudder angle indicator only operates to 20 degrees to STBD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2013
Resolution: Received tech report and Flag statement attesting to the repair of vessels rudder angle indicator.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 May 2013
Resolved
Vessels has temparary patch on 1 foot section of piping leading to ships sewage tank.
Action required: 705 - Other - as specified
Due 19 June 2013
Resolved 21 June 2013
Resolution: Attending Marine Inspector witnessed new section of pipe that was installed to replace the wasted section.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 9 November 2012
Resolved
0135 - Personnel - Every vessel subject to CCSSC shall have a minimum safe manning document. Vessel has switched flags and has not received copy of minimum safe manning document from administration. CCSSC 1.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2012
Resolution: Vessel provided minimum safe manning document and is in compliance.
Electrical › Electric Generation Source (service) › Panelboard
Issued 12 October 2012
Resolved
1499 - Other - Main and emergency switchboards should be arranged to give easy access and should have no exposed live parts. Vessel has debris behind electrical switchboard. The vessel also has a panel that is not showing amps and has clear access through the panel to the electrical components system. CCSCC CH.2.27.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2013
Resolved 29 January 2013
Resolution: Received, reviewed and accepted class report from Panama Maritime Documentation Services stating the deficiency was rectified. Six missing gauges for the electrical panel were replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 October 2012
Resolved
1460 - Guards and Fencing - Condition of ship should ensure that in all aspects will remain fit to proceed to sea without danger to persons on board. Vessels STBD generator does not have a guard over the belts, which causes a safety hazard. CCSC CH. 1.11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2012
Resolved 9 November 2012
Resolution: CG examiner witnessed an installed guard over vessels STBD generator belts.
Documentation › Logs/Records › Oil Record Book
Issued 10 September 2012
Resolved
Oil record book is not been propely updated as events occur. Oil record book has had no entries since April, 2012.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2012
Resolved 10 September 2012
Resolution: Oil Record Book has been properly updated and reflects all transfers correctly.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 June 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2012
Resolution: A copy of a application of [name withheld] was provided by company operator.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Chief Mate
Issued 8 June 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2012
Resolution: New chief mate sent to vessel.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 8 June 2012
Resolved
Emergency fire pump portable was not in operational condition. Repair / replaced portable emergency fire pump prior to departure from the port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2012
Resolution: New portable emergency fire pump procured.
Fire Fighting › Firemans Outfit › Quantity
Issued 8 June 2012
Resolved
Firemen outfit not on board for inspection. As per CCSSC certificate a firemen outfit should be on board. Provide a firmen outfit as describe by the CCSSC certificate prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2012
Resolution: New fire fighting outfits procured and placed on board.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 15 December 2011
Resolved
First officer do not available a valid endorsement or current application from Flag. Provide a endorsement or a copy of the application for endorsement from flag prior to departure. STCW 78 II/4.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2011
Resolved 21 December 2011
Resolution: First Officer application for endorsement has been sent, we have copy of application.
Lifesaving › Inflatable Liferafts › Servicing
Issued 15 December 2011
Resolved
STBD side liferaft servicing is overdue, Re-service or replace liferaft with proper installation prior to departure. CCSSC Chap 5.7.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2011
Resolved 21 December 2011
Resolution: New liferaft has been placed on board with new hydrostatic release.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 December 2011
Resolved
Vessel do not have on board two portable 2 way VHF radiotelephone. Provide two vhf portables radios prior to departure CCSSC Chap 5.7.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2011
Resolved 21 December 2011
Resolution: Two VHF portable radios have been placed on board.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 15 December 2011
Resolved
Emergency fire pump is out of service / not operational. Repair or replaced emergency fire pump prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2011
Resolved 21 December 2011
Resolution: Tested emergency fire pump, is working properly. New hoses have been placed on board, instructed Captain to stencil with vessel name.
Fire Fighting › Fire Hoses › Condition
Issued 15 December 2011
Resolved
Vessel is missing 1 of the 2 fire hoses required. Replace a fire hose prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2011
Resolved 21 December 2011
Resolution: New hoses have been placed on board.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 15 September 2011
Resolved
Original Min Safe Manning and Caribbean Cargo Ship Safety Certificate were not on board. Originals are required to be placed on board at next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 September 2011
Resolution: ATTENDED VESSEL AND VERIFIED ORIGINAL DOCUMENTS ON BOARD
Electrical › Electric Generation Source (service) › Generator
Issued 31 January 2011
Resolved
Ship's second electrical generator is not operational. Generator engine was out of order. Repair / Replace generator to satisfaction to local U.S. Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2011
Resolution: Ships generator’s back on operational status.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 April 2005
Resolved
Prior to Bunkering in U.S. waters, to include to or from the vessel or tank to tank within the vessel, provide evidence of Oil Transfer Procedure to the cognizant OCMI I.A.W 33 CFR 155.750.
Action required: 703 - Prior to bunkering operations
Due 26 April 2005
Resolved 19 May 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 April 2005
Resolved
Prior to next U.S. port, provide current light list.
Action required: 15 - Rectify deficiencies by next port
Due 26 April 2005
Resolved 19 May 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2005
Resolved
Prior to next U.S. port, refresh name and hailing port on all Lifebuoys
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2005
Resolution: DEF CORRECTED.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 October 2004
Resolved
Provide flag state endorsement for master and chief mate licenses.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Resolution: def corrected
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 18 October 2004
Resolved
Provide required manning in accordance with miniumum safe manning document.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Resolution: def corrected
Engineering › Steering Gear System › Ram
Issued 18 October 2004
Resolved
Demonstrate proper operation of vessels steering system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Resolution: def corrected
Operations/Management › Drills/Instruction › Fire
Issued 18 October 2004
Resolved
Demonstrate proper fire and abandonship drills in the presence of a Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Resolution: def corrected
Electrical › Lighting (emergency)
Issued 9 February 2004
Resolved
Prove proper operation of both Emergency Light fixtures located in engine room athwartship passageway. LEGACY COMPONENT DESC: Lighting Fixture
Due 9 March 2004
Resolved 14 June 2004
Resolution: def corrected
Engineering › Fuel Oil Service System
Issued 9 February 2004
Resolved
Provide and install metal splash shield for all RACOR fuel filters. LEGACY COMPONENT DESC: Filter
Due 9 March 2004
Resolved 14 June 2004
Resolution: def corrected
Navigation › Piloting/Steering
Issued 9 February 2004
Resolved
Provide current magnetic compass Deviation Card prior to departing the port of ST. Thomas, VI. LEGACY COMPONENT DESC: Deviation Table/Graph
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2004
Resolved 14 June 2004
Resolution: def corrected.
Electrical › Electrical Distribution System (service)
Issued 9 February 2004
Resolved
Remove all stores and install non-conducting matting for rear of engine room electrical switchboard. LEGACY COMPONENT DESC: Switchboard
Due 9 March 2004
Resolved 14 June 2004
Resolution: def corrected
Fire Fighting › Miscellaneous Items
Issued 9 February 2004
Resolved
Make permanent repairs to Fire Alarm push button station in engine room.
Due 9 March 2004
Resolved 14 June 2004
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety
Issued 9 February 2004
Resolved
Install anti-slip surface in way of decks & platforms in machinery spaces, floor of galley, decks at winches & areas at the foot & head of ladders and in front of doors and steps of ladders.
Due 9 March 2004
Resolved 14 June 2004
Resolution: def corrected
Construction/Loadline › Structures
Issued 9 February 2004
Resolved
Identify engine room Emergency Escape hatch. LEGACY COMPONENT DESC: Machinery Space Opening
Due 9 March 2004
Resolved 14 June 2004
Resolution: def corrected
Documentation › Certificates/Documents
Issued 27 March 2003
Resolved
Provied evidence of the supplement list for the CCSSC.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 March 2003
Resolution: Recieved fax of vessel''s CCSSC with supplement list from flag.
Documentation › Certificates/Documents
Issued 24 March 2003
Resolved
Provide evidence of the supplement list for the CCSSC.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 March 2003
Fire Fighting › Fire Pumps
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, make both fire/bilge pumps operable. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2002
Resolution: Both fire/bilge pumps made operable and tested satisfactory.
Personnel › Manning/Qualifications
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, provide all required personnel IAW vessel safe manning document. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2002
Resolved 12 April 2002
Resolution: Adequate crew provided.
Lifesaving › Inflatable Liferafts
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, attach liferafts painters to vessel with appropriate weak link devices. LEGACY COMPONENT DESC: Weak Link
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2002
Resolution: Liferafts properlt rigged.
Lifesaving › Inflatable Liferafts
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, test or renew liferaft hydrostatic release units. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2002
Resolution: Hydrostatic release units renewed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, make operable watertight cover for emergency fuel shut-off controls.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2002
Resolution: Watertight cover repaired.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, make operable engine room escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2002
Resolution: Hatch repaired.
Operations/Management › Drills/Instruction
Issued 10 April 2002
Resolved
Prior to departing St Thomas, USVI, conduct fire and abandon ship drills to the satisfaction of the attending Coast Guard inspector. LEGACY COMPONENT DESC: Fire
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2002
Resolution: Proper drills conducted.
Fire Fighting › Combustible Materials
Issued 10 April 2002
Resolved
Remove paint from steering room and store in appropriate fire protected space. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Placed in Improper Service
Due 10 May 2002
Resolved 10 May 2002
Construction/Loadline › Structures
Issued 10 April 2002
Resolved
Remove unauthorized door in engine room forward bulkhead. LEGACY COMPONENT DESC: Door
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 10 April 2002
Lifesaving › Buoyant Smoke Signals
Issued 10 April 2002
Resolved
Repair electrical lights on both man overboard smoke signals.
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 10 May 2002
Navigation › Piloting/Steering
Issued 10 April 2002
Resolved
Provide light list, coast pilot, tide & tidal current tables or acceptable substitute. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 May 2002
Resolved 10 May 2002
Navigation › Piloting/Steering
Issued 10 April 2002
Resolved
Provide updated compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Due 30 May 2002
Resolved 10 April 2002
Communications › Radio Communications
Issued 10 April 2002
Resolved
Renew EPRIB hydrostatic release unit. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 12 April 2002
Resolution: EPRIB hydrostatic release renewed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 April 2002
Resolved
Make magnetic compass light operable.
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 11 April 2002
Resolution: Compass light repaired and tested satisfactory.