Records from 2003 to 2025. Most recent: inspection, 10 March 2025.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 27 August 2014
Resolved
STBD engine failed full power trails due to an overheat. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Full power conducted for 10 minutes with no problems.
Stability › Unintentional Flooding › General
Issued 27 August 2014
Resolved
Water is entering vessel through a hole in the hull at the stern, port side. FRP matting is soaked. Remove damaged FRP and repair as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Operations/Management › Drills/Instruction › Fire
Issued 27 August 2014
Resolved
Man overboard drill was unsuccessful. Demonstrate proper man overboard drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Successfully completed MOB drill
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 August 2014
Resolved
40 PFD's were provided for inspection. COI requires 44. Provide 4 more Type I PFDs are required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2014
Resolution: Replaced with ones from a vessel no longer in service.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 27 August 2014
Resolved
Fammable/Combustible materials such as thinner and resin were being stowed under passenger seating. Remove as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2014
Resolution: Reomved from vessel
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 August 2014
Resolved
Storage of Typr I Child PFD's not labeled. Provide as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2014
Resolution: Marked child PFD storage as required.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 27 August 2014
Resolved
PFD donning instructions missing. Provide and post as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Installed new placarding in cabin and aft main deck
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 August 2014
Resolved
Anchor light inoperable. Provide an operable anchor light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 August 2014
Resolved
Dead end electrical wires found throughout vessel. Remove all unused/dead-end electrical wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Electrical › Electrical Distribution System (service) › Switch
Issued 27 August 2014
Resolved
Battery cable switch missing cover on STBD side. Provide cover as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Fuel Oil Service System › Valve
Issued 27 August 2014
Resolved
Emergency fuel cut-out valve remote handles missing label. Install label as required.
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Labeled as required
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 27 August 2014
Resolved
Emergency Broadcast Instructions indicate incorrect call sign. Provide correct information.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 27 August 2014
Resolution: Installed new plaquard with correct information
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 August 2014
Resolved
Electrical wire ends are taped together throughout the vessel. Install proper wire connectors as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Lifesaving › Hand Flares › Storage
Issued 27 August 2014
Resolved
Container for distress signals not properly marked. Mark as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Labeled as required
Engineering › Bilge Water Management System › Pump
Issued 27 August 2014
Resolved
Installed bilge pump for port hull does not meet the UL 1113 standard. Install as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Replaced with Rule UL 1113 pump
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 27 August 2014
Resolved
Four Type III child PFD's were found unservicable. Destroy as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 27 August 2014
Resolution: Destroyed in the presence of the CG MI.
Construction/Loadline › Structures › Superstructure
Issued 27 August 2014
Resolved
Rotten wood plank in interior of cabin found on STBD side of battery. Crop and renew rotten wood.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 29 October 2014
Resolution: All rotten material scarfed out from location
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 August 2014
Resolved
Last fire and man overboard drill was conducted in excess of 3 months. Conduct drill and record as required.
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Successfully completed and logged man overboard and fir drill
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 August 2014
Resolved
Raw water hose to reduction gear cooler wasted. Replace with CG approved material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Bilge Water Management System › Hose
Issued 27 August 2014
Resolved
Hoses for bilge pump overboard and r/w inlet to engine cooling single hose clammped. Double hose clamp as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Fuel Oil Service System › Filter
Issued 27 August 2014
Resolved
Fuel filters equipped with drain cocks without a cap. Cap drain cocks or remove as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Bilge Water Management System › Hose
Issued 27 August 2014
Resolved
Bilge pump discharge hose of poor quality (No reinforcement). Replace with hose of appropriate material.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 27 August 2014
Resolved
Dry portion of port engine exhaust not insulated. Provide proper insulation as required.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 27 August 2014
Resolved
Dripless shaft seal installed improperly. Install as per manufactures instruction or replace with new.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Removed tape and hose clamp. Installed perminate fasteners for compression ring. Shaft still leaking about 10 drops per minute. Owner intends on replacing bearing with new packing gland assembly
Electrical › Electric Generation Source (service) › Generator
Issued 27 August 2014
Resolved
Alternator installed improperly. Mount as per manufacture instruction.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Engineering › Bilge Water Management System › Pump
Issued 27 August 2014
Resolved
Port FWD bilge pump float switch will not float freely. Repair or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 August 2014
Resolved
Port side negative battery cable is not marine grade. Replace with requred UL boat cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Cable replaced with marine grade UL boat cable
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 27 August 2014
Resolved
Port engine clutch cable separated from sleeve. Replace cable with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Replaced with new
Engineering › Reduction Gearing/Clutches › Hose
Issued 27 August 2014
Resolved
Port reduction gear lube oil hose to cooler cracked. Replace with new SAE J-1942 hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2014
Resolved 5 September 2014
Resolution: Replaced with new
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 27 August 2014
Resolved
Port engine hard to start, vibrates excessively and emits large amounts of white smoke. Repair to proper operating condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2014
Resolution: Repaired to the satisfaction of the attending marine inspector
Stability › Watertight Integrity › General
Issued 31 August 2012
Resolved
Replace damaged watertight hatch located on stbd side, center hatch, midships.
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 1 October 2012
Resolution: Witnessed proper repair of hatch.
Construction/Loadline › Structures › Superstructure
Issued 6 July 2012
Resolved
Replace damaged windows located on vessel's superstructure.
Action required: 705 - Other - as specified
Due 31 October 2012
Resolved 29 May 2013
Construction/Loadline › Structures › Superstructure
Issued 6 July 2012
Resolved
Crop and renew as original numerous delaminated fiberglass and wood rot located on the vessel's superstructure.
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 1 October 2012
Resolution: Witnessed proper repairs.
Stability › Watertight Integrity › General
Issued 6 July 2012
Resolved
Repair / replace port-holes located on both port and stbd sides.
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 1 October 2012
Resolution: Witnessed proper repairs.
Engineering › Bilge Water Management System › Pump
Issued 30 May 2012
Resolved
Secure port bilge pump.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Bilge pump secured.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 May 2012
Resolved
Demonstrate proper operation of forward port bilge alarm.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Bilge alarm operational.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 May 2012
Resolved
Secure anchor light pole.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Anchor light pole secured.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 30 May 2012
Resolved
Label radio breaker.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Breaker labeled.
Electrical › Electrical Distribution System (service) › Switch
Issued 30 May 2012
Resolved
Provide covers for back of both port and starboard battery switches.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Covers provided.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 May 2012
Resolved
Provide drug and alcohol policy statement.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Statement provided.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 May 2012
Resolved
Provide crewmember drug awareness training.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Training completed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 May 2012
Resolved
Provide alcohol testing devices onboard vessel.
Due 30 June 2012
Resolved 28 June 2012
Resolution: Alcohol testing devices provided but kept ashore due to temperature restrictions.
Lifesaving › Hand Flares › Quantity
Issued 23 August 2011
Resolved
Provide 04 hand held red flares or 4 orange day time smoke distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2011
Resolution: Smoke signals provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 August 2011
Resolved
Provide proof of enrollment into drug testing program.
Due 30 August 2011
Resolved 24 August 2011
Resolution: DAPI enrrollment documentation provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 August 2011
Resolved
Provide operational VHF radio.
Action required: 705 - Other - as specified
Due 24 August 2011
Resolved 24 August 2011
Resolution: New radio installed and tested satisfactorily.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 August 2011
Resolved
Update expired items in first aid kit.
Due 30 August 2011
Resolved 19 October 2011
Resolution: Expired items updated.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 August 2011
Resolved
Removed dead ended wire from port hull.
Due 30 August 2011
Resolved 24 August 2011
Resolution: Wire removed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 August 2011
Resolved
Provide proper battery for ring buoy water light.
Due 30 August 2011
Resolved 19 October 2011
Resolution: Proper battery provided.
Operations/Management › Drills/Instruction › Fire
Issued 23 August 2011
Resolved
Conduct fire and man overbaord in the presence of a Coast Guard inspector.
Due 30 August 2011
Resolved 19 October 2011
Resolution: Satisfactory drills conducted.
Construction/Loadline › Hull › Hull Plating
Issued 3 August 2011
Resolved
Provide repair proposal and conduct permanent repair to hole in starboard hull. Vessel is not to carry passengers for hire until repairs are completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2011
Resolution: Hull repaired.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 12 October 2010
Resolved
Stop use/remove BBQ (charcoal) grill.
Due 12 October 2010
Resolved 12 October 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 September 2010
Resolved
Replace retro tape on lifejackets as needed.
Due 14 September 2010
Resolved 13 October 2010
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 1 September 2010
Resolved
Seal/properly re-construct P/S engine boxes (machinery spaces).
02SEP10: boxes sealed, latches for access need to be repaired/replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 13 October 2010
Lifesaving › Lifebuoys › Serviceable
Issued 1 September 2010
Resolved
Replace lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Construction/Loadline › Hull › Transverse Frame
Issued 1 September 2010
Resolved
Properly tighten fwd main beam stbd fastener.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Engineering › Bilge Water Management System › Pump
Issued 1 September 2010
Resolved
Provide hand bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 September 2010
Resolved
Repair stern light.
Due 14 September 2010
Resolved 2 September 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 September 2010
Resolved
Double hose clamp raw water and bilge hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Fire Fighting › Fire Bucket › Quantity
Issued 1 September 2010
Resolved
Provide a total of (3) fire buckets w/lanyards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 2 September 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 September 2010
Resolved
Install collision bhd panels.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2010
Resolved 3 September 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 August 2008
Resolved
Vessels COD is expired as of 31 Aug 2008, awaiting favorable status from VDC.
Action required: 705 - Other - as specified
Resolved 19 August 2009
Resolution: Vessels COD is current and in favorable status.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 May 2008
Resolved
Replace six (06) lifejackets. Reduce pax count to 43 until deficiency is corrected.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 8 July 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 May 2008
Resolved
Conduct and Log drills and monthly EPIRB test.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Engineering › Fuel Oil Service System › Filter
Issued 27 May 2008
Resolved
Install shield on port side MDE fuel filter.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 May 2008
Resolved
Replace all plastic wire hangers with metal hangers.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Resolution: Vessels reps installed wire hangers with proper spacing.
Lifesaving › Lifebuoys › Approval
Issued 27 May 2008
Resolved
Replace lifering with CG approved lifering.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Resolution: Vessels reps replaced ring with approved type.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 May 2008
Resolved
provided proof of enrollment for Drug and Alcohol program.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 8 July 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 27 May 2008
Resolved
Replace plastic through hull valves with metal valves
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Resolution: Vessels reps replaced all plastice through hull valves with metallic caps, all sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 May 2008
Resolved
Provided service report for fire extinguishers.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Resolution: All extinguishers are all sat with inspection dates.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 May 2008
Resolved
Install missing screws on forwrd deck.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Construction/Loadline › Hull › Side Shell
Issued 27 May 2008
Resolved
Make port cat hull midship damage section available fro inspection.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Resolution: Vessels reps opened area and proved area is dry, requested owner to repair with a 12:1 repair.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 May 2008
Resolved
Install forward mast head light.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 29 May 2008
Resolution: Vessels reps installed and tested new fwd nav light.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 August 2006
Resolved
Replace calbes to pull stations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 11 August 2006
Resolved
Connect cables to bottles on system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 August 2006
Resolved
Make permanent repairs to E/R blkhds to ensure FF agent is effective.
Due 25 August 2006
Resolved 1 September 2006
Lifesaving › Lifefloat › Serviceable
Issued 11 August 2006
Resolved
Replace ring buoy.
Due 25 August 2006
Resolved 1 September 2006
Engineering › Fuel Oil Service System › Piping
Issued 11 August 2006
Resolved
Repair/replace fuel shut off cables and pipes.
Due 25 August 2006
Resolved 1 September 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 August 2006
Resolved
Install high level visual alarms for bilge.
Due 25 August 2006
Resolved 1 September 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 August 2006
Resolved
Replace port bilge alarm.
Due 25 August 2006
Resolved 1 September 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 August 2005
Resolved
Replace retroreflective tape on lifejackets as needed.
Due 19 August 2005
Resolved 5 August 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 August 2005
Resolved
Replace/repair stbd side bilge high water alarm/indicator.
Due 19 August 2005
Resolved 19 August 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 August 2005
Resolved
Install bench supports on port side bench.
Due 19 August 2005
Resolved 19 August 2005
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 5 August 2005
Resolved
Provide valid radio operators permit.
Due 19 August 2005
Resolved 21 August 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 5 August 2005
Resolved
Repair fixed firefighting equipment. Engines did not shut down upon system activation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2005
Lifesaving › Lifebuoys › Serviceable
Issued 19 August 2004
Resolved
Replace/repair ring life buoy.
Due 2 September 2004
Resolved 2 September 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 19 August 2004
Resolved
Provide radio station license.
Due 2 September 2004
Resolved 2 September 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 19 August 2004
Resolved
Provide valid Radio Safety Certificate.
Due 2 September 2004
Resolved 2 September 2004
Lifesaving › Lifebuoys › Serviceable
Issued 19 August 2004
Resolved
Install detachable clip on Buoy light
Due 2 September 2004
Resolved 2 September 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 19 August 2004
Resolved
Replace fire extinguisher at operating station.
Due 2 September 2004
Resolved 27 August 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 August 2004
Resolved
Provide proof of servicing.
Due 2 September 2004
Resolved 2 September 2004
Engineering › Sea-water System (primary cooling) › Valve
Issued 19 August 2004
Resolved
Replace/repair R/W sea valve.
Due 2 September 2004
Resolved 2 September 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 August 2004
Resolved
Replace/repair port bilge high level alarm.
Due 2 September 2004
Resolved 27 August 2004
Engineering › Bilge Water Management System › Not Operational
Issued 19 August 2004
Resolved
Demonstrate proper operation.
Due 2 September 2004
Resolved 27 August 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 19 August 2004
Resolved
Properly mark Emergency Escape Hatches.
Due 2 September 2004
Resolved 2 September 2004
Documentation › Markings/Placards › Official Number (US)
Issued 8 April 2003
Resolved
Engrave or otherwise permanently attach vessel official numbers to hull interior or main structural member of hull. Numbers to be at least three inches in height and of block-type Arabic numerals. Numbers must be so afixed that alteration, removal or replacement will be obvious. 46 CFR 67.121.
Due 3 August 2003
Resolved 20 August 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 April 2003
Resolved
Provide MSO Guam with a copy of vessel's Certificate of Documentation, reflecting new name of vessel.
Due 3 August 2003
Resolved 20 August 2004
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2003
Resolved
Replace all existing CG Approved Type A1 fuel hose with fuel hose meeting SAE J-1942 specifications, including factory attached end fittings.
Due 2 September 2004
Resolved 27 August 2004
Stability › Severe Wind/Roll › General
Issued 8 April 2003
Resolved
Vessel owner to contact MSO Guam when ready to perform vessel stability test to be witnessed by CG Marine Inspector. Test to be conducted to make final determination for total number of passengers allowed. Until such time this number can be determined, vessel is restricted to 27 total persons.
Due 3 August 2003
Resolved 20 August 2004