MAURY USCG vessel records
← All vessels

USNS 1ST LT JACK LUMMUS

Built
1986
Last inspected
26 February 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 February 2026
…with no type recorded10
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8302454
265629
Flag
UNITED STATES
Maury page id
psix-265629

Documentation record

Tonnage as PSIX records it32903 - Regulatory (Subpart C or D), Gross Ton
44543 - Convention (Subpart B), Gross Ton
25384 - Regulatory (Subpart C or D), Net Ton
14461 - Convention (Subpart B), Net Ton
26523 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 45 inspections, each with its date, unit and type; 44 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 45

26 February 2026 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8316795
22 January 2026 ACP Periodic Oversight · Periodic Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8299841
20 January 2026 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8308308
24 October 2025 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8259677
17 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8160804
27 January 2025 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8070093
16 January 2025 Appeal · ACP Annual Oversight · Administrative Inspection · Vessel Attendance · Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8059828
4 October 2024 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8035154
27 June 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7944097
10 June 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7932060
20 October 2023 ACP COI Oversight · ACP Drydock Oversight · Re-Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7811719
21 February 2023 Annual Inspection · ACP COI Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7637963
22 June 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7484341
18 March 2022 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7414064
18 February 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7401127
27 November 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7364311
15 November 2021 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7353331
1 October 2021 Administrative Inspection · ACP Periodic Oversight · Periodic Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7324418
8 March 2021 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7127869
21 December 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7241636
26 October 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7084051
6 January 2020 Deficiency Check · Ballast Water Examination · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6883121
10 October 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6831839
6 August 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6774668
19 July 2019 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6758379
3 December 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6591562
19 November 2018 Deficiency Check · ACP COI Oversight · ACP Drydock Oversight · Special · ACP Additional Oversight – Risk Assessment · Administrative Inspection · Underwater Inspection in lieu of Drydock · Re-Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6625795
12 November 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6579474
2 November 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6583121
26 October 2018 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6569011
29 August 2018 Deficiency Check · Periodic Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6535919
27 August 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6535936
27 July 2018 Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6497507
5 July 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6552087
19 January 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6342559
18 January 2018 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6356982
22 November 2017 ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6310539
9 November 2017 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6304191
17 January 2017 Annual Inspection · ACP Periodic Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6071272
29 October 2016 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6031552
28 October 2016 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6034972
15 September 2016 Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6020587
9 July 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6163694
16 May 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5878450
5 May 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5869751

Deficiency record · 44

02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 17 June 2025 Resolved
The administration shall satisfy itself that the general structural strength of the hull is sufficient for the draft corresponding to the free board assigned. Ships built and maintained in conformity with the requirements of a classification society recognized by the administration my be considered to possess adequate strength. The master reported that the vessel lost its port anchor chain while conducting an anchor test at the Saipan anchorage. An ABS surveyor attended the vessel to conduct a damage survey. The surveyor reported that the outboard shear pin pad-eye lower weldment inside of the chain locker void was observed with a micro-fracture and weeping fuel oil from the contiguous fuel oil tank. The crew transferred fuel below the fracture to prevent additional seepage. ABS approved temporary repairs to the affected area so that the vessel may transit to South Korea for permanent repairs. Provide a satisfactory repair proposal to ABS for approval prior to making final repairs. Provide an ABS survey report to USCG MSU Saipan after repairs are completed to the satisfaction of the attending ABS surveyor. ICLL Ch. 1 Reg 1
Action required: 10 - Deficiency Rectified
Due 17 July 2025
Resolved 17 June 2025
Resolution: ABS surveyor attended. WO 7047346 was issued and the repair will be verified by ABS in South Korea.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 January 2025 No resolution recorded
Sprinklers shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application rate of not less than 5 liters per square meter per minute over the nominal area covered by the sprinklers. Cargo holds #1 and #2 are loaded with containerized cargo, hazard class 1 explosive cargo, and the containers are stacked above the water sprinkler coverage area. There are no fire fighting measures for the explosive cargo stacked above the fixed sprinkler system in cargo holds #1 and #2. SOLAS 74 Ch. II-2 Reg 12(c) Class provided finding 1458.0 stating: It is recommended that this matter be resolved between the flag state and OPCO as flag state approved fire safety at new construction. Deficiency action code changed from "a" to "c" on May 7, 2025. This deficiency was appealed and is at CVC level, awaiting response. The deficiency was upheld by CVC. CVC response permits the 835 to be extended to the next dry dock. New extension date updated to the defienciency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 January 2025 Resolved
In all new and existing ships, fire-fighting appliances shall be kept in good order and available for immediate use at all times during the voyage. The paint locker's fixed CO2 fire extinguishing system flexible hoses are not marked with the test date and no written records were found on board for testing or renewing the hoses. SOLAS 74 Ch. II-2 Reg 15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 21 August 2025
Resolution: Received ABS report with finding number.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 January 2025 Resolved
Ventilator openings shall be provided with weather tight closing appliances. The gasket for the air escape gooseneck vent on the main deck, stbd side of centerline, at the #2 hatch, was found wasted. ICLL 1966 Ch. 1 Reg 19.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 21 August 2025
Resolution: Received ABS report with finding number.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 January 2025 Resolved
The muster list shall specify definite signals for calling all the crew to their boat, liferaft, and fire stations, and shall give particulars of these signals. These signals shall be made on the whistle or siren and they shall be supplemented by other signals which shall be electronically operated. The emergency alarm bells in the engine room were found inoperable. The alarms do not match the muster list alarms found on board the vessel used to notify crew members of an emergency. SOLAS 74 Ch. III Reg 25(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 21 March 2025
Resolution: The affected engine room alarm bells have been repaired and made operable to the satisfaction of the attending Surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 January 2025 Resolved
The ship, whether new or existing, shall carry at least two fireman's outfits complying with the requirements of Regulation 14 of this Chapter. Administrations may require in large ships additional sets of personal equipment. In accordance with MSC/USCG MOA dated 22AUG2024, Annex III – Modification of Standards, 5.c, vessel was unable to produce two or four axes per fireman’s ensembles. SOLAS 74 Ch. II-2 Reg 52(j)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 7 May 2025
Resolution: It is recommended that fireman's ensembles be outfitted with acceptable hatchets, as per Flag state interpretation of MSC/USCG MOA dated 22AUG2024, Annex III - Modification of Standards, 5 .c.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 June 2024 Resolved
The administration shall satisfy itself that the general structural strength of the hull is sufficient for the draft corresponding to the free board assigned. Ships built and maintained in conformity with the requirements of a classification society recognized by the administration my be considered to possess adequate strength. The master reported that the vessel is holed in the shell plate, approximately 3/16" diameter, at the starboard transom frame 258 behind the starboard stern ladder. Crew members witnessed sea water enter the vessel through the shell plate hole. The crew moved ballast on-board to prevent additional sea water from entering the vessel. The master reported that the crew will temporarily repair the hole prior to arrival in Saipan, CNMI, where a third party ABS surveyor can attend the vessel. Provide an ABS survey report to USCG MSU Saipan after the surveyor attends the vessel. ICLL Ch. 1 Reg 1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2024
Resolved 19 July 2024
Resolution: ABS attended the vessel and oversaw approved repairs to the holed weld at frame 258.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2023 Resolved
(a) Seventeen cubic meters (600 standard cubic feet) or less of acetylene may be stowed on or below decks on any vessel. There were 12 bottles of Acetylene stored in the passageway forward of the CO2 room. Determine the volume of the bottles, and move any bottles in excess of 600 cubic feet, to a location open to the weather decks, IAW ABS 4-6-7/7.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2024
Resolution: Master reported that excess bottles of acetylene have been relocated to the wx deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 October 2021 Resolved
Main source of electrical power shall consist of at least two generating sets. Vessel has 3 ship service diesel generators, 2 of which are experiencing operability issues. #2 SSDG down due to issues with Auto Voltage Regulator (AVR) #1 SSDG experiencing issues with tripping offline while running at random times, engineers onboard troubleshooting. Vessel shall make effective repairs to restore at least two generating sets for electrical power prior to departure. Vessel authorized to shift in [name withheld] anchorage area and complete short runs in local vicinity of harbor for routine discharge ops at sea. Harbor assistance tugs shall be on standby. 74 SOLAS (1981) II-1/41.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2021
Resolution: Short term SLC certificate issues with due date of 22FEB2022 for satisfactory repairs - parts and technician estimated for attendance in late Nov/early Dec.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 28 October 2021 Resolved
Fireman's outfits & equipment shall be ready for immediate use. Noted 08 defective regulator hoses for various self-contained breathing appartuses throughout the vessel (refer to 2021 Harris Fire Servicing Report for specific SCBA serial numbers). Hoses shall be replaced with satisfactory replacements as per manufacturer recommendation. 74 SOLAS II-2/52(i)(iii)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2021
Resolved 16 November 2021
Resolution: Vessel meets minimum number of fire fighters outfits specified in SOLAS II-2/10.2. Deficiency will be tracked by ABS due to inclusion of additional bottles (20 total) on approved fire control plan.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 6 January 2020 Resolved
OIL FINTERING EQUIPMENT SHALL BE OF A DESIGN APPROVED BY THE ADMINSTRATION AND SHALL BE SUCH AS WILL ENSURE ANY OILYMIXTURE DISWCHARGE INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAD AN OIL CONTENT NOT EXCEEDING 15 PARTS PER MILLION. THE VESSELS OIL FILTERING EQUIPMENT FAILED TO OPERATE AS DESIGNED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 24 February 2020
Resolution: SLUDGE WAS REMOVED FROM THE OWS, OPERATIONAL RECIRCULATION TEST CONDUCTED WITH [name withheld] OF ALARM HISTORY CONDUCTED. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020 Resolved
DATA SHALL BE STAMPED DIRECTLY ON THE PRESSURE VESSELS. tHE VESSELS START AIR RECEIVER TANKS ARE MISSING DATA PLATES.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 24 February 2020
Resolution: DATA PLATES WERE COVERED IN PAINT, PAINT WAS REMOVED AND THE REQUIRED DATA WAS MADE VISIBLE.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 September 2018 Resolved
46 CFR 113.25-12(a),(c): Total of 06, general alarm signals located in interior of house and on secon flat/motor room in bow thruster space are inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2018
Resolution: Verified general alarms at locations work.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 September 2018 Resolved
SOLAS 74 III/9(a)(ii): The engine and its accessories shall be suitably enclosed to ensure operation under adverse weather conditions. Make repairs to No. 1, starboard motor air shroud cover with hole.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2018
Resolution: Crew cropped out hole on air shroud and replaced with new metal to as original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 September 2018 Resolved
A safety system shall be provided to ensure that serious malfunction in machinery or boiler operations, which presents an immediate danger, shall initiate the automatic shut-down of that part of the plant and that an alarm shall be given. The electrical component that controls the low lube oil and engine over speed shutdowns for the emergency diesel generator is operating intermittently, the emergency generator operates normally despite the intermittent issue and supplies power to the ships emergency bus. Repair/replace electrical component, should the emergency generator be run for an extended period to provide emergency power prior to the repair or replacement of the component, regular rounds of the emergency generator space shall be made to monitor operations. SOLAS 74(81 Amend.) II-1/52
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 21 June 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 September 2018 Resolved
The function of the detection system shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fire which the detector is designed to respond. The smoke detector in the A-Deck laundry room did not activate or alarm when tested. Repair/replace smoke detector. SOLAS 74(81 Amend.) II-2/13.1.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2018
Resolved 20 September 2018
Resolution: Verified locally and remotely smoke detector alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2018 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. A dead ended wire was found on the starboard side main deck. Remove or isolate wire in a junction box to eliminate potential electrical hazards. SOLAS 74(81 Amend.) II-1/40.1.3
Action required: 10 - Deficiency Rectified
Due 18 September 2018
Resolved 18 September 2018
Resolution: Dead ended electrical wire was removed. all sat.
Fire Fighting › Fire Main › Condition
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed.) II-2/21 and 46 CFR 91.45-1: Repair fire main line in way of fire main station No. 91, with pin hole leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repairs completed and main tested to the satisfaction of attending MI and Class Surveyor.
Fire Fighting › Fire Main › Condition
Issued 22 November 2017 Resolved
SOLAS 74/78 (81 ed) II-2/21 and 46 CFR 91.45-1: Repair wasted foam pipe at fire main station No. 97, on flight deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repair and tested to the satisfaction of attending MI and Class Surveyor.
Fire Fighting › Nozzles › Condition
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed) II-2/21 and 46 CFR 91.45-1: Repair engine room bilge foam sprinkler starboard side nozzle wasted and broken off. Upon completion of repair, bilge foam sprinkler lines must be flushed out with water and waste removed from bilge prior to next USCG visit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repaired and tested to the satisfaction of attending MI.
Fire Fighting › Fire Main › Condition
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed) II-2/21 and 46 CFR 91.45-1:Repair main salt water pipe for bilge foam sprinklers severely pitted forward of main engine below deck plate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repaired and tested to the satisfaction of the attending MI.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed.) II-2/21: Remove paint from pressure switch in front of paint locker room on Level 63 and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Verified by attending MI and tested by attending Class Surveyor.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 November 2017 Resolved
46 CFR 91.45-1 & SOLAS 74/78 II-1/3-1: Repair EDG emergency remote fuel oil shut off valve broken off and inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repaired and tested to the satisfaction of the attending MI.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 22 November 2017 Resolved
SOLAS 74/78 II-1/43: It was observed that the fuel oil tank level would not supply all those services that are essential for safety in an emergency for the required period hours. Maintain EDG fuel oil tank to 95%.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Verified to the satisfaction of the attending MI.
Fire Fighting › Combustible Materials › Insulation
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed) II-2/51: Remove oil soaked lagging on lube oil valves throughout engine room and replace with new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Replaced with new lagging to the satisfaction of attending MI.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 November 2017 Resolved
ICLL 66 Reg. 1 and 46 CFR 42.09-50: Provide proof of Class approval for alteration (circular cutout) made to overhead above 63 Level in way of watertight hatch cover near machine shop.
Action required: 705 - Other - as specified
Resolved 29 November 2017
Resolution: Attending Class Surveyor assessed and witnessed satisfactory watertight test with crew. Class approved penetration in overhead of Level 63. See Class Survey Report attached under Documents.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 November 2017 Resolved
SOLAS 74/78 II-2/20.1: Update fire control plant to show installed smoke detector in emergency diesel generator space and submit to Class for approval. Onboard ship’s approved fire control plan only shows Heat as the fire detection system for EDG space.
Action required: 705 - Other - as specified
Resolved 29 November 2017
Resolution: Class verified and approved updated Fire Control Plan. See Class Survey report saved under Documents.
Lifesaving › Launching Appliances › Davit
Issued 22 November 2017 Resolved
SOLAS 74/78 (14 cons) III 20.2: Repair aft horizontal bracket for No. 4, forward horizontal bracket for No. 6 and horizontal sheave guard for No. 3 lifeboats with wastage.
Action required: 705 - Other - as specified
Due 22 November 2018
Resolved 21 June 2019
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed) II-2/44.1: Replace missing fire stop in cable penetrations through bulkhead in various workshops (Service spaces-high risk) and low pressure CO2 space (Control station) on 63 Level.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 November 2017 Resolved
46 CFR 111.01-1: Remove or properly cap off exposed dead end wires penetrating through bulkhead in way of MOGAS pump #2, in cargo pump room.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom Ventilation
Issued 22 November 2017 Resolved
46 CFR 91.45-1: Repair wasted ventilation openings and ducts to as original in cargo pump room.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 22 November 2017 Resolved
46 CFR 111.01-1: Install chaffing guard on float sensor cable in way of MOGAS pump #1, in cargo pump room.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 November 2017 Resolved
46 CFR 91.25-45: Remove all waste oil in engine room bilge and make ready for USCG inspection.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Engineering › Fuel Oil Service System › Heater
Issued 22 November 2017 Resolved
SOLAS 74 (81 ed) II-2/51: Secure leak on #3 SSDG lube oil heater and crank case access covers.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Communications › Alarms/Indicators › General Alarm
Issued 22 November 2017 Resolved
46 CFR 113.25-9: Repair inoperable general alarms in crew passage way in vicinity of machine shop and low pressure CO2 room on 63 Level.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2017 Resolved
46 CFR 50.01-10: Rotate lagging on forward boiler’s main steam stop valve to the top and re-fastened.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Engineering › Lubricating Oil Service System › Piping
Issued 22 November 2017 Resolved
46 CFR 50.01-10: Repair piping not secured to brackets throughout engine room (example: lube oil purifier from main sump and bilge suction pipe port side).
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 November 2017 Resolved
46 CFR 50.01-10: Repair main salt water discharge line for gauge leaking and built up with salt.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 November 2017 Resolved
46 CFR 91.45-1 / ICLL 66 Reg. 1: Repair main Deck 1-2050 passage door with cracked glass porthole.
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 29 November 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2017 Resolved
46 CFR 111.01-1: Repair electrical panel detached from bulkhead in crew laundry.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 November 2017 Resolved
46 CFR 190.70(b)(3) and (4)(i): Stencil missing vessel name onto life jackets and replace expired life jacket lights with new.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2017 Resolved
46 CFR 91.45-1: Repair water leak from overhead pipe in machine shop on Level 63.
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 21 December 2017
Resolution: Verified by C/E that there was no leak. Removed paint and traced line with no evidence of a water leak. See email correspondence attached under Documents dtd 21DEC2017, from C/E.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 29 October 2016 Resolved
Make permanent repairs to pump room and equipment affectred by pump room fire.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 December 2016
Resolved 17 January 2017
Resolution: See activity: 6071272
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 15 September 2016 Resolved
Crew installed flexible hose with spigot to "decant" waste oil. Installatio was not approved by ABS or USCG
Due 17 October 2016
Resolved 19 September 2016
Resolution: Captain sent email stating that hose installation was removed by crew. Will verify during Nov 16 ACP.

Recorded names · 1

1ST LT. JACK LUMMUS (2003–2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.