MAURY USCG vessel records Sign in
← All vessels

OMA

OMA is a 1974 freight ship. The Coast Guard has recorded 33 inspections since 2003, most recently in January 2024, along with 50 deficiencies and 20 operational controls.

Records from 2003 to 2024. Most recent: inspection, 26 January 2024.

Built
1974
Last inspected
26 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7368607 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
563929
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-563929

Inspections, by type

…with no type recorded21
Years with a record 9 calendar years (2003–2024)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14731 - Dead Weight, Ton
891 - Regulatory (Subpart C or D), Gross Ton
891 - Convention (Subpart B), Gross Ton
552 - Regulatory (Subpart C or D), Net Ton
552 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FAMILY ISLAND Freight Ship · MISLE 274406 · 31 October 2008 · activity 3356398

Inspection history · 33

26 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856174
10 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3942071
10 January 2011 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3924142
28 December 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3916229
27 December 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3916523
14 September 2010 Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3849400
31 October 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3356398
21 July 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3274553
10 October 2007 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3077050
22 March 2007 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2892576
19 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2890372
17 July 2006 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2715761
14 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2712671
3 January 2006 ISPS III Exam · NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2559508
18 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2536865
6 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2509192
1 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2505275
22 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2471677
14 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2426653
12 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2423563
12 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2424387
6 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2381873
1 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2376011
25 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2341927
16 March 2005 NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2311512
13 May 2004 Type not recorded
No type recorded · USCGC DALLAS (WHEC 716) · Activity 2066306
22 December 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1968132
3 November 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1941643
25 July 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1856617
22 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1853856
4 April 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1768238
13 March 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1756869
10 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1754998

Deficiency record · 50

Construction/Loadline › Structures › Superstructure
Issued 14 September 2010 Resolved
Cargo hatches are missing dogs and can not be made watertight
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 14 September 2010 Resolved
Rudder angle indicator at princple steering station is innacurate by more than 5 degrees
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 September 2010 Resolved
Plastic site glass is installed in lie of steel piping on overboard side of OWS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2010
Navigation › Collision/Grounding Avoidance › Transponder
Issued 14 September 2010 Resolved
AID is broadcasting "MV OMA" instead of "OMA" has the vsl's name
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 14 September 2010 Resolved
Vsl does not have an LRIT Conformance Test Report
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2010
Operations/Management › Drills/Instruction › Safety Orientation
Issued 14 September 2010 Resolved
REQUEST THIRD PARTY AUDIT OF SMS DUE TO IMPROPER LOADING PROCEDURES. VESSEL WAS NOT LOADED IN ACCORDANCE WITH THE VESSEL'S CARGO SECURING MANUAL.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 January 2011
Resolution: RECEIVED ISM AUDIT REPORT. NEW FULL TERM ISM DOCUMENTS HAVE BEEN ISSUED.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 14 September 2010 Resolved
VESSEL DOES NOT HAVE A COMPLETE AND APPROVED STABILITY BOOKLET.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 January 2011
Deck/Cargo › Cargo Stowage › General
Issued 14 September 2010 Resolved
Cargo above hatch covers not secured in accordance with vessel cargo securing manual. Multiple vehicles and other misc. cargo was secured to cargo hatch cover wheels and hatch comings. Additionally, tensioners on securing devices were secured with twine pelican hooks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2010
Resolution: Securing arrangements were shifted to permanently affixed D-clamps on deck. Pelican hooks for tensioners were replaced with wire.
Engineering › Bilge Water Management System › Pump
Issued 31 October 2008 Resolved
Vessel must have oily water in bilge removed by a certified hazmat removal company. Currently approximately 3 inches of oily water in machinery bilges. Vessel must provide receipt of oily water removal to Sector Miami.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 2 October 2008 Resolved
Captain does not have a valid GMDSS Certificate. Provide proof of competency.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 2 October 2008 Resolved
Chief Mate has no endorsement for GMDSS. Provide Flag endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 2 October 2008 Resolved
2nd Engineer has no medical certificate. Provide proper documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 21 July 2008 Resolved
Provide all valid certificates with endorsements prior to any cargo operations or departure from port. Vessel had an expired Cargo Ship Safety Radio Certificate and did not have current endorsements for the International Ship Security, International Load Line Certificate, and International Oil Pollution Prevention Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2008
Resolution: All Certificates are current and have valid endorsments.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 July 2008 Resolved
Vessel must have a complete USCG inspection prior to departure from port or loading cargo
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2008
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 21 July 2008 Resolved
Provide a valid Certificate of Financial Responsibility
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2008
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 21 July 2008 Resolved
Provide Evidence of most recent dry-dock. Date was not noted on the Cargo Safety Construction Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2008
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 21 July 2008 Resolved
Provide dry dock dates and endoresments on Cargo Ship Safety Construction Certificate.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 December 2010
Documentation › Markings/Placards › Warning Signs
Issued 10 October 2007 Resolved
BRIDGE REQUIRED STEERING GEAR DIAGRAM
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 18 October 2007
Resolution: Steering gear diagram posted on bridge.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 October 2007 Resolved
VSL NEEDS TO UPDATE NOTICE TO MARINERS AND CHART CORRECTIONS, AND PROVIDE A CHART CORRECTIONS LOG.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 18 October 2007
Resolution: Chart corrections made, chart correction log being used.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 10 October 2007 Resolved
GMDSS AND SIDEBAND RADIO TEMPORARY INOP DUE TO SERVICING.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 26 January 2024
Resolution: Radios serviced and reinstalled. Test complete, properly working
Documentation › Logs/Records › Logbook (official)
Issued 10 October 2007 Resolved
VSL NEEDS TO UPDATE GMDSS LOG
Action required: 705 - Other - as specified
Due 10 October 2007
Resolved 18 October 2007
Resolution: GMDSS log updates and correct entries made.
Fire Fighting › Fire Main › Valves
Issued 10 October 2007 Resolved
STBD AFT SECTION OF THE FIRE MAIN AS THE VLAVE HAS A LEAK
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 18 October 2007
Resolution: Fire Main repaired by replacing valve and small pipe.
Construction/Loadline › Structures › Deck Plating
Issued 10 October 2007 Resolved
DECK PLATING ON THE FORECASTLE IS WASTED AND RUSTED THROUGH.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 18 October 2007
Resolution: Deck plating replaced on the Forcastle.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 October 2007 Resolved
OWS WILL NOT START, OVERBOARD DISCHARGE HAS BEEN SECURED.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 18 October 2007
Resolution: Power supply repaired, OWS tested and working properly.
Communications › Radio Communications › Satellite Communications Capability
Issued 22 March 2007 Resolved
Sarts on board have batteries removed ,new batteries are in-route to vessel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2007
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 22 March 2007 Resolved
Suits onboard are proximity suits not fire fighting suits per FSS code
Condition: Design Flaw
Due 29 March 2007
Resolved 3 April 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 22 March 2007 Resolved
Equipment and radio certs are expired. Flag issued an extention untill 30 March 07.
Due 30 March 2007
Resolved 3 April 2007
Stability › Weathertight Integrity › General
Issued 22 March 2007 Resolved
March 14, 2007 Vessel was struck by another vessel in Haiti. Request Administration asses damages for seaworthiness.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2007
Construction/Loadline › Markings › Load Line Mark
Issued 22 March 2007 Resolved
Load line markings for regional waters not permantly fixed to vessel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2007
Electrical › Electric Generation Source (service) › Conductor
Issued 22 March 2007 Resolved
Battery box for winch on port bridge wing is broken and battery is exposede to weather. Nails and jagged wood also appear to be hazzardous.
Condition: Damaged By Earlier Event
Due 21 April 2007
Resolved 21 April 2007
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 22 March 2007 Resolved
Anchors shackle broke. contractors are hired to retrieve anchore and re attach. request administration survey anchor and chain.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 3 January 2006 Resolved
Emergency fuel shutdown is not operational for SS GEN #2 Inspectors doubt the operation of all emergency fuel shutdowns.
Action required: 705 - Other - as specified
Due 3 January 2006
Resolved 10 January 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 January 2006 Resolved
Update fire control plan to reflect EEBD locations and halon alarm. FCP must be approved by vessels flag administration
Action required: 705 - Other - as specified
Due 3 January 2006
Resolved 10 January 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 January 2006 Resolved
OWS piping system diargram and instructions were missing. Permanently post diargram and instructions.
Action required: 705 - Other - as specified
Due 3 January 2006
Resolved 10 January 2006
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 12 July 2005 Resolved
Vessel entered U.S. waters without submitting a proper NOA. Vessel was issued COTP denying entry. Vessel proceeded to Miami anchorage after having received COTP order.
Action required: 705 - Other - as specified
Resolved 13 July 2005
Lifesaving › Rescue Boat Equipment
Issued 25 June 2003 Resolved
Prove current rescue boat davit installationis origional or provide motor for raising rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2003
Fire Fighting › Fire Main
Issued 4 April 2003 Resolved
Pipe patch in STBD firemain piping. Permanently and properly repair firemain. LEGACY COMPONENT DESC: Material
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2003
Resolution: croped and renewed
Documentation › Certificates/Documents
Issued 4 April 2003 Resolved
Vessel's current Safety Radio Certificate was only good for one voyage. Provide a valid Safety Radio Certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2003
Resolution: New Safety Radio Cert. issued.
Operations/Management › Drills/Instruction
Issued 4 April 2003 Resolved
Vessel unable to complete drills due to adverse weather. Complete fire and abandon ship drills. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2003
Resolution: Drills completed - Sat.
Fire Fighting › Fire Main
Issued 13 March 2003 Resolved
Make permanent and proper repairs to fire main piping to the satisfaction of flag surveyor. LEGACY COMPONENT DESC: Condition
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Resolution: Tested sat onboard.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 13 March 2003 Resolved
Make permanent & proper repairs to Halon alarm in engine room to the satisfaction of flag surveyor.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Documentation › Certificates/Documents
Issued 13 March 2003 Resolved
Expired or missing three certificates: COFR, Registration Certificate, and Safety Radio Certificate. Status of all certificates shall be verified by flag surveyor.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Stability › Weathertight Integrity
Issued 13 March 2003 Resolved
All port holes are not weathertight due to wastage. Repair to the satisfaction of the flag surveyor.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 13 March 2003 Resolved
Provide proper cover behind switchboard. Repair to the satisfaction of the flag state. Also, verify that space behind the switchboard is not used as a storage room. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Construction/Loadline › Structures
Issued 13 March 2003 Resolved
Make permanent and proper repairs on deck and hull to the satisfaction of flag state; doublers are not acceptable. LEGACY COMPONENT DESC: Deck Plating & Hull
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Communications › Radio Communications
Issued 13 March 2003 Resolved
Replace incorrect hydrostatic release on EPIRB; it is currently using one for liferafts (i.e. not for EPIRB). LEGACY COMPONENT DESC: EPIRB
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Documentation › Certificates/Documents
Issued 13 March 2003 Resolved
Update fire plan to indicate the exact location of International Shore Connection (ISC) and lifesaving equipment (i.e. fire suites). LEGACY COMPONENT DESC: Fire Plan
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Engineering › Lubricating Oil Storage/Transfer System
Issued 13 March 2003 Resolved
Make proper repairs to cargo hydraulic lines to the satisfaction of flag state surveyor. Doublers are not acceptable. LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Fire Fighting › International Shore Connection
Issued 13 March 2003 Resolved
Provide washers for international shore connection. This shall be certified by the flag state surveyor. LEGACY COMPONENT DESC: Washers
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003
Deck/Cargo › Cargo Stowage
Issued 13 March 2003 Resolved
Replace worn cargo hatch retraction cables. This shall be certified by flag state surveyor. LEGACY COMPONENT DESC: Retraction cables
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2003

Ownership record