Records from 2002 to 2007. Most recent: inspection, 1 April 2007.
Documentation record
Registered dimensions (L × B × D)38.0 ft × 14.0 ft × 4.6 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLAMETTE JETBOAT EXCURSIONS LLC · PORTLAND, OR, UNITED STATES · built 2002
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portWISCONSIN DELLS, WI
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
16 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
1 April 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3158192
15 March 2007
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2886592
25 July 2006
Damage Survey · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2725530
28 April 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2632326
4 May 2005
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2343576
1 July 2004
Simplified Stability Test · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2113824
20 May 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2074312
5 April 2004
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2031094
24 March 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2017256
16 May 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1794917
17 April 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1771020
20 November 2002
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1713939
30 April 2002
COI Inspection · Hull Examination · Construction Oversight · Simplified Stability Test
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1661861
Construction/Loadline › Structures › Superstructure
Issued 22 July 2006
Resolved
Renew windshield where broken. Passengers may not be carried until broken glass is removed from the vessel.
Condition: Placed in Improper Service
Due 25 July 2006
Resolved 25 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 28 April 2005
Resolved
Submit proposal for making perm. repairs to hull: (a) insert btm shell plating IWO fracture, portside on coll. blkhd seam; (b) insert lower portion of coll.blkhd due to multiple fractures/holes; (c) insert side shell portside (dblr repair) IWO letter "P" (in vessel name on bow); (d) mods to int struct. framing fwd of coll. blkhd.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2005
Resolved 4 May 2005
Resolution: Satisfactory proposal submitted for repairs to hull and repairs verified by attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 April 2004
Resolved
Renew the battery in the ring buoy float light (check mfg requirements for battery). Vessel may not operate at night until corrected. 46 CFR 180.70 (d) LEGACY COMPONENT DESC: Float Light
Due 5 May 2004
Resolved 4 May 2005
Resolution: Proved operation ring buoy float light satisfactorily.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 April 2004
Resolved
Provide original Certificate of Inspection, to be placed on board the vessel. This certificate must be on board prior to the carriage of passengers. 46 CFR 176.100
Due 5 May 2004
Resolved 8 April 2004
Operations/Management › Drills/Instruction
Issued 5 April 2004
Resolved
Provide an emergency instruction list. The emergency instructions should be applicable to the vessel's route and operation. 46 CFR 185.510 LEGACY COMPONENT DESC: Emergency Instructions
Due 5 May 2004
Resolved 20 May 2004
Stability › Incline Test › General
Issued 5 April 2004
Resolved
Have vessel undergo a new simplified stability test. 46 CFR 178.210 (Due to post-removal of hard boat top) Until this has been corrected, vessel may carry not more than 49 passengers. LEGACY COMPONENT DESC: Simplified Test
Due 5 May 2004
Resolved 1 July 2004
Engineering › Bilge Water Management System
Issued 17 April 2003
Resolved
Replace the bilge overboard hose with an approved type. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Due 17 May 2003
Resolved 23 April 2003
Documentation › Certificates/Documents
Issued 17 April 2003
Resolved
Provide valid FCC operator and station license. LEGACY COMPONENT DESC: FCC Licenses
Condition: Unknown
Due 17 May 2003
Resolved 23 April 2003
Documentation › Markings/Placards
Issued 17 April 2003
Resolved
Provide an emergency broadcast placard and mount close to the radio. LEGACY COMPONENT DESC: Emergency Broadcast Placard
Condition: Unknown
Due 17 May 2003
Resolved 14 May 2003
Engineering › Compressed Air System (control)
Issued 15 August 2002
Resolved
Prove proper operation of Port air tank relief valve. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2002
Resolved 15 August 2002
Navigation › Collision/Grounding Avoidance
Issued 30 April 2002
Resolved
Complete Installation of horm and prove proper operation of same.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2002
Resolved 8 May 2002
Resolution: Corrected
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 30 April 2002
Resolved
Mount two(2) B-1 fire extinguishers in passenger space.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2002
Resolved 8 May 2002
Resolution: Corrected
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 April 2002
Resolved
Install gas shocks on aft passenger cabin doors to assit onboard air system for operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 May 2002
Resolved 14 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 April 2002
Resolved
Label Emergency release valves for Passenger cabin doors.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2002
Resolved 8 May 2002
Resolution: Corrected
Operations/Management › Passenger Operations
Issued 30 April 2002
Resolved
Complete Installation of Videao Monitoring System for passenger space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 May 2002
Resolved 8 May 2002
Resolution: Corrected.
Lifesaving › Hand Flares › Quantity
Issued 30 April 2002
Resolved
Provide 3 smoke and 3 orange flares in brightly colored and labeled container.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2002
Resolved 8 May 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 April 2002
Resolved
Repair locking assembly on Portside passenger space door.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2002
Resolved 8 May 2002
Resolution: Corrected.