Records from 2016 to 2022. Most recent: inspection, 26 October 2022.
Inspection history · 18
26 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7584385
20 August 2022
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7538663
18 August 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7650141
3 August 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7522445
20 July 2022
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7510394
11 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7154443
22 February 2021
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7144749
10 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6871120
9 December 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6870594
18 November 2019
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6858526
6 December 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6592591
16 November 2017
Administrative Inspection · Annual Survey · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6310395
14 November 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6306660
27 October 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6031054
10 October 2016
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6026629
8 June 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5901198
13 January 2016
Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5796928
8 January 2016
Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5793948
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 August 2022
No resolution recorded
During a damage survey, Marine Inspectors did not see applicable charts to the proper scale for the transit outbound of Galveston. Provide evidence to USCG Marine Inspectors that a chart to proper scale has been brought on board the vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2022 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 3 August 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must be equipped with an MF-DSC radiotelephone transmitter and receiver. Vessel has no MF radio transmitter installation on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 11 August 2022
Resolution: Vessel submitting FCC exemption request for installation of MF installation due to superior satellite based communications package on board.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 August 2022
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Hailing Port on vessel is New Orleans, LA, does not match Galveston, TX as noted on COD or on other vessel certificates.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 11 August 2022
Resolution: Vsl provided documentation showing updated hailing port on vessel stern.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 December 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. The vessels charts did not contain any chart corrections. Vessel shall ensure charts are kept corrected for intended area(s) of operation. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2019
Resolution: Chart corrections completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 December 2019
Resolved
Except as otherwise provided in this section, 177.900, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. At the time of inspection, vessel was missing removable chains on the aft cargo deck. Vessel shall keep chains strung across the aft cargo deck except when operations permit. 46 CFR 177.900(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2019
Resolution: Aft removable chain rails installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 December 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Raw water overboard discharge hose for the #1 MDE clutch was discovered bulging with a 3" soft spot. Vessel shall. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2019
Resolution: Overboard raw water flexible hose replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 December 2018
Resolved
Lifefloat attached floating waterlight is not working and must be replaced with an operable one per 46 CFR 180.175(f)(4).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2018
Resolved 7 December 2018
Resolution: Corrected on the spot.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 6 December 2018
Resolved
18421 - The guard for the ventilation blower in the generator room is broken and inadequate, which needs to be replaced per 46 CFR 177.960.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2018
Resolved 6 December 2018
Resolution: Installed a new guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2018
Resolved
13199 - Two fuel strainers are missing flame shilds, which need to be installed with metallic drain plugs per 46 CFR 182.455(b)(6).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2018
Resolved 7 December 2018
Resolution: Installed new flame shields.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 December 2018
Resolved
The lifejacket stowage container in the wheelhouse must identify the number of lifejackets it contains per 46 CFR 185.604(f).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2018
Resolved 6 December 2018
Resolution: Placard placed on the stowage compartment. Corrected on the spot.
Lifesaving › Lifefloat › Serviceable
Issued 16 November 2017
Resolved
Lifefloats' color has faded and need to be repainted prior to the vessel departing to the satisfaction of a CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: All repainted.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 16 November 2017
Resolved
FCC Bridge-to-Bridge license is expired and needs to be renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Licensed 3rd party issued new FCC license.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 November 2017
Resolved
Emergency light in rudder room is inoperable and needs to be corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Light bulb changed out.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 16 November 2017
Resolved
#4 MDE was inoperable, which needs to be prepared and then conduct a propulsion check.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Starter fixed, propulsion tested. All sat.
Construction/Loadline › Hull › Weld
Issued 16 November 2017
Resolved
Cracked welds were identified on both port and starboard side boom collar to bulwarks welds.
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Welds were gouged out and redone. All sat.
Communications › Radio Communications › EPIRB
Issued 16 November 2017
Resolved
EPIRB hydrostatic release unit is expired and must be replaced prior to the vessel departing to the satisfaction of a CG marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Hydrostatic release unit was replaced.
Construction/Loadline › Structures › Scupper
Issued 16 November 2017
Resolved
Freeing port on starboard side bulwarks in the cargo deck area is damaged and needs to be fixed/rewelded.
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: Freeing port was repaired.
Fire Fighting › Fixed Deck Foam System › Foam Applicators
Issued 16 November 2017
Resolved
Firefighting foam in-line eductor for the fire hose stations is not working.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2017
Resolution: In-line eductor was fixed.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 October 2016
Resolved
VHF digital selective calling was not operable.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 October 2016
Resolved 11 October 2016
Resolution: Corrected.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 October 2016
Resolved
Did not have a current copy of US Coast Pilot onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 10 October 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 October 2016
Resolved
Did not have a current copy of CG Light List onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 11 October 2016
Resolution: Corrected on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 10 October 2016
Resolved
#2 Main Diesel automatic shutdown did not function when fixed CO2 extinguishing system pressure switch was activated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 11 October 2016
Resolution: Replaced MDE control box, retested CO2 system automatic shutdown pressure switch. All sat.
Lifesaving › Lifefloat › Painter
Issued 10 October 2016
Resolved
Painter was not secured to one of the lifefloats (in tandem).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 10 October 2016
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 October 2016
Resolved
Ring lifebuoy self-igniting light was not operable, and was not attached to the ring lifebuoy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 10 October 2016
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 October 2016
Resolved
Crew conducted a man overboard drill which was not satisfactory due to not being capable of preparing the rescue platform as well as not properly donning a rescue harness, while also taking far too long to recover someone in a real-life situation (stopped after 15 minutes).
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2016
Resolution: Crew ran drill again; addressed all issues and swiftly carried out the drill to my satisfaction.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 October 2016
Resolved
Crew conducted an abandon ship drill not to my satisfaction. Crew did not: make a distress call, break out distress signals, grab the EPIRB or donn Type I PFDs properly.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2016
Resolution: Crew ran abandon ship drill again, addressed all issues to my satisfaction.