Records from 2014 to 2025. Most recent: inspection, 12 December 2025.
Inspection history · 17
12 December 2025
PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8279948
28 July 2024
COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7969156
24 May 2023
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7694657
18 August 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7650141
16 June 2022
PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7470954
10 June 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7474847
28 May 2021
Deficiency Check · PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7201283
28 May 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7247358
21 May 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7202902
20 May 2021
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7201691
22 June 2019
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6717607
10 January 2018
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6334134
12 February 2017
COC-TVE Renew · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6083624
12 February 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6087047
11 February 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6086584
5 October 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4992080
5 October 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5001176
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 28 May 2021
Resolved
AUDIBLE AND VISUAL ALARMS ARE TO BE INITIATED IN THE CARGO CONTROL ROOM, NAVIGATION BRIDGE AND AT THE ANALYSING UNIT WHEN THE VAPOUR CONCENTRATION IN A GIVEN SPACE REACHES A PRE-SET VALUE. PSCO OBSERVED NO AUDIBLE OR VISUAL ALARM AT THE CONTROL PRANEL IN THE CARGO CONTROL ROOM FOR THE WATER BALLAST TANK SENSORS FOR THE FIXED HYDROCARBON GAS DETECTION SYSTEM.
SOLAS 74 (14) II-2/4.5.7.3.1
FSS CODE 16.2.2.3.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2021
Resolution: Verified tech report replacing and testing of hyrdocarbon gas sensor. Class report confirmed acceptance of repairs/replacement.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 12 February 2017
Resolved
The last 1.0 meter (3.3 feet) of vapor piping before the vessel vapor connection must be labeled "VAPOR" in black letters at least 50 millimeters (2 inchs) high. Vapor line was not marked with "VAPOR". 46CFR39.20-1(d)(2) 50c
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 21 February 2017
Resolution: Received email from vessel Master attesting to the rectification of the deficiency.