SALACIA

SALACIA is a 2000 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 2016, most recently in May 2026, along with 31 deficiencies and 5 casualty investigations between 2006 and 2021.

Records from 2006 to 2026. Most recent: inspection, 11 May 2026.

Built
2000
Last inspected
11 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 May 2026
…with no type recorded38
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF4062
Flag
UNITED STATES
Maury page id
psix-5672

Documentation record

Registered dimensions (L × B × D)126.8 ft × 39.0 ft × 12.5 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)126.8 ft × 39.0 ft × 12.5 ft
ITC tonnagegross 537 / net 213
BuilderDUCLOS CORP DBA GLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 2000
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Regulatory (Subpart C or D), Net Ton
213 - Convention (Subpart B), Net Ton
167 - Displacement, Ton
91 - Regulatory (Subpart C or D), Gross Ton
537 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 81

11 May 2026 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8371156
31 March 2026 Damage Survey · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8338830
25 February 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8305552
11 June 2025 Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8166744
20 March 2025 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8091862
6 March 2025 Plan Review (Other than "T")
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8110035
7 November 2024 Deficiency Check · Internal Structural Exam · In-Service Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8031689
13 December 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7830094
4 September 2023 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7784669
4 September 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7784821
29 June 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7723955
2 June 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7713370
5 May 2023 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7672372
25 January 2023 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7616399
18 January 2023 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7626047
13 October 2022 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7571088
12 May 2022 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7444050
8 February 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7392734
19 November 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7354216
8 August 2021 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7280602
8 August 2021 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7281174
20 May 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7201602
1 April 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161236
31 March 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7166371
25 January 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7131655
24 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6978061
24 January 2020 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6896828
10 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6871079
25 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841798
13 May 2019 MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6682799
15 March 2019 Plan Review "T" Boat · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6638568
13 December 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6597040
10 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6536866
10 September 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6537036
20 June 2018 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6448895
30 April 2018 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6400783
20 April 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6397412
3 April 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6384574
19 March 2018 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6374730
19 March 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6379463
12 March 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6370335
5 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6318245
28 June 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6189739
16 May 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6146509
20 April 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6124493
17 March 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6107858
13 March 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6103810
7 February 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6084023
7 February 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6084026
7 February 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6084030
7 February 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6084033
8 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037908
8 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037910
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037186
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037189
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037191
7 November 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037192
2 September 2016 MTSA Verification · Damage Survey · Security Breach
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5990309
16 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5942559
16 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5942575
9 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5934959
4 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5929321
4 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5929322
4 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5929635
4 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5929646
3 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5929286
3 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5929317
26 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5919436
26 June 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5919503
25 May 2016 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5886685
29 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5865295
29 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5865304
29 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5865321
29 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5865379
8 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5849792
8 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5849799
25 February 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5821981
19 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5800117
19 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5800121
19 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5800126
19 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5800128

Deficiency record · 31

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 February 2026 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Inflatable survival craft were ashore for servicing and not available for inspection. Limited to 1 mile from shore.
Action required: 705 - Other - as specified
Resolved 11 May 2026
Resolution: Verified serviced IBAs were properly re-installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 June 2025 Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F of this chapter. The vessel's approved DVTPs for the Reversing bucket system were in correcntly subbmitted for approval. Re-submit the proper DVTP for the reversing system to the Marine Safety Center.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 26 June 2025
Resolution: Operator re-submitted DVTPs to MSC
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 March 2025 Resolved
Whenever deterioration to hull plating that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural exam (ISE) and may require the vessel to effect permanent repairs. During the ISE, found three isolated pitts in the #2 Port void, bay one, clad weld to the satisfaction of the CGMI.
Action required: 705 - Other - as specified
Due 30 May 2025
Resolved 11 June 2025
Resolution: All pitts were properly clad welded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of electrical equipment and systems. Repair all Marine Cable Transits (MCT) in the port and stbd engineroom. Cracked, not properly installed. Submit to USCG product that vessel intends to use to ensure proper approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 11 June 2025
Resolution: All Marine Cable Transits were properly sealed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of electrical equipment and systems. Re-seal stbd jet room aft bulkhead Marine Cable Transit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 11 June 2025
Resolution: All Marine Cable Transits were properly sealed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of electrical equipment and systems. Re-seal port jet room aft bulkhead Marine Cable Transit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 11 June 2025
Resolution: All Marine Cable Transits were properly sealed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall have the vessel ready for inspection of the hull structure and its appurtenances, including inspection of all railings and bulwarks and their attachment to the hull structure. Repair the 2 identified areas on aft 01 deck railing at the corners.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 11 June 2025
Resolution: Deck railing was properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 March 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Inspect all house mounts and replace damaged mounts and hardware to the satisfaction of the [name withheld] requires isolation kits to ensure stainless hardware does not come in contact with aluminum.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 11 June 2025
Resolution: Item was extended by Sector Boston. This item was cleared and a new item was issued by [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 November 2024 Resolved
Carbon dioxide cylinders forming part of a fixed fire extinguishing system must be maintained as follows: cylinders must be retested every 12 years. The fixed fire CO2 cylinders were last hydro tested in 2011. Schedule and have serviced hydro test for the CO2 cylinders.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2024
Resolved 8 January 2025
Resolution: Vessel had cylinders hydro tested with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2024 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the OCMI. The starboard side engine room portable fire extinguisher bracket was broken. Repair/replace bracket to OCMI satisfaction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 8 January 2025
Resolution: Fire extinguisher bracket was replaced with a new approved bracket and mounted in the original location.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 7 November 2024 Resolved
waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacle on the bridge was made of combustible material. O/O is to remove or replace with proper style non-combustible waste receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 8 January 2025
Resolution: Waste recepticles were replaced with ones of metal construction.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 November 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlet receptacle outside the port electrical closet in main deck passenger space had a loose top outlet showing an open ground. O/O is to repair or replace to satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 8 January 2025
Resolution: Outlet was replaced and operational test was conducted in the presence of the attending CGMI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 November 2024 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. The battery for the ring life buoy water light was expired. Crew member replaced battery during the inspection.
Action required: 10 - Deficiency Rectified
Due 7 November 2024
Resolved 7 November 2024
Resolution: Crew member replaced battery during the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlet receptacle in port side aft jet room had a broken cover. O/O is to repair or replace receptacle cover to the satisfaction of attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 7 November 2024
Resolved 7 November 2024
Resolution: Crew members replaced the cover with a new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2024 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel’s STBD side bilge pump had a cracked male threaded pipe adjoining the bilge pump to the bilge suction line. O/O to repair or replace threaded pipe to the satisfaction of attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 7 November 2024
Resolved 7 November 2024
Resolution: Pipe section was replaced in kind and satisfactory tests were conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 November 2024 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel’s port side #2 void bilge suction line pipe union was severely deteriorated and leaking. O/O is to repair or replace piping union to satisfaction of attending marine inspector.
Action required: 10 - Deficiency Rectified
Due 7 November 2024
Resolved 7 November 2024
Resolution: pipe union was replaced in kind to the satisfaction of the attending CGMI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2024 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. O/O is to repair or replace all overhead and vertical cable support hangers with metal supports/retention devices spaced no more than 48 inches apart prior to next credit hull/drydock exam.
Action required: 705 - Other - as specified
Due 31 May 2025
Resolved 20 March 2025
Resolution: Supports added
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 September 2023 Resolved
A vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Aluminum hull vessels: (1) Rules and Regulations for the Classification of Yachts and Small Craft, Lloyd's; or (i) For a vessel of more than 30.5 meters (100 feet) in length—Rules for Building and Classing Aluminum Vessels, ABS. Vessel allided with the pier after disembarking passengers in Provincetown, MA. Found vessel's starboard quarter external structure inset approximately 2 inches by 1 foot, with a popped butt weld between the top rail and topmost longitudinal external frame. Structure comprised of external sheet aluminum, framing, and welded tube which protects the jet drive and scoop, aft of each hull. No penetration witnessed in the watertight envelope of starboard hull upon internal and external inspection. Repairs shall be made to return vessel to original design, to the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 2 November 2023
Resolution: Verified repaired fashion plate and rewelding of cracked welds. Visual NDT accepted as repair made to non watertight envelope.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 September 2023 Resolved
Immediately after addressing resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest sector office, marine inspection office, or Coast guard group office, whenever a vessel is involved in a marine casualty consisting of an occurrence materially and adversely affecting the vessel's seaworthiness or fitness for service or route. Vessel allided with the pier while mooring in Provincetown, MA causing damage to the vessel and the pier. Vessel is required to conduct a damage survey and any necessary repairs to the satisfaction of the attending USCG marine inspector. 46 CFR 122.202
Action required: 60 - Rectify deficiencies prior to movement
Due 5 September 2023
Resolved 4 September 2023
Resolution: USCG Sector Boston attended vessel, found no further damage. Cleared Def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2023 Resolved
Except as provided in paragraph (d) of this section, this subpart applies to each self-propelled vessel that (1) Carries oil of any kind as fuel for propulsion; (2) Is not a tank vessel; (3) Operates upon the navigable waters of the United States; and (4) is 400 gross tons or more as measured under the convention measurement system. Vessel does not have a Nontank Vessel Response Plan (NTVRP). Provide copy of NTVRP.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2023
Resolved 14 August 2023
Resolution: Recieved NTVRP approval letter.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 January 2023 Resolved
A pull cable used to activate the system controls must be enclosed in conduit. Cable pulley box in Port Side CO2 system cover is disconnected and deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2023
Resolution: Pulley box was properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel suffered a fire onboard in starboard engine room due to an overheated PTO hydraulic pump on #3 MDE. Vessel is restricted from carrying passengers until repairs are made to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2021
Resolution: Temporary repairs completed and approved.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 June 2020 Resolved
Controls and valves for operation of a fixed gas fire extinguishing system must be located outside the space protected by the system; and not located in a space that might be inaccessible in the event of fire in the space protected by the system. System engine shutdown pressure switched located inside of the protected space on both hulls. Submit plan to OCMI for relocation of engine shutdown pressure switches outside of the protected space. Upon approval relocate switches to a location outside of the protected space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 25 January 2021
Resolution: Equivelancy request approved.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 24 June 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. 04 cracked longitudinal welds marked in the port and stbd forepeak. Repair weld to the satisfaction of attending marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 26 June 2020
Resolution: Cracked welds in port and stbd forepeak repaired.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
Vsl is broadcasting invalid IMO # and no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 October 2018
Resolution: While running a query in VIVS, the draft and IMO number for the vessel had been updated and AIS was broadcasting the proper information.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 20 June 2018 Resolved
Piping for stbd CO2 system is wasted. Have fire servicing technician attest to integrity of system or renew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 2 July 2018
Resolution: Attended the vessel with Gorham fire rep to discuss tests/inspections conducted on piping. Piping system Sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 June 2018 Resolved
Ensure fire control plan is posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 2 July 2018
Resolution: 02 fire control plans posted.
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2018 Resolved
Replace 3 temporary repair patches (approx 4x6 inches) with proper full inserts of new plate in way of scrape damage on starboard quarter.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 16 May 2018
Resolution: Repairs complete, test welds, all sat.
Construction/Loadline › Hull › Hull Plating
Issued 19 March 2018 Resolved
Prior to carrying passengers, provide temporary repairs to 3 holes in hull, stbd aft above waterline, and provide repair for gouges to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2018
Resolved 20 March 2018
Resolution: Temporary repair patches inspected and tested satisfactorily using air lance. Fill welding on gouge inspected satisfactorily.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 13 March 2017 Resolved
All of the vessel's inflatable buoyant apparatus have been removed for annual servicing. The vessel is limited to a Lakes, Bays, and Sounds route not more than one nautical mile from shore until the IBAs have been re-installed to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 23 March 2017
Resolution: Verified annual servicing and proper reinstallation of four IBAs.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 25 February 2016 Resolved
THE VESSEL'S INFLATABLE BUOYANT APPARATUS HAVE BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL'S ROUTE IS LIMITED TO LAKES, BAYS & SOUNDS AND NOT MORE THAN ONE NAUTICAL MILE FROM SHORE UNTIL THE IBA HAVE BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 25 March 2016
Resolution: IBA's installed and ispected

Casualty record · 5

3 January 2006Routine · role: Involved in a Marine Casualty · activity 2559828
17 November 2012Routine · role: Involved in a Marine Casualty · activity 4487035
17 March 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6107858
19 March 2018Routine · role: Involved in a Marine Casualty · activity 6379463
8 August 2021Routine · role: Involved in a Marine Casualty · activity 7281174
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.