Records from 1992 to 2026. Most recent: inspection, 6 March 2026.
Inspection history · 110
6 March 2026
Internal Structural Exam · Vessel Attendance · Drydock Exam · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8312011
25 November 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8265256
16 October 2024
COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7999975
10 January 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7845484
28 November 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7822132
5 May 2023
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7681772
19 January 2023
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7615364
16 February 2022
Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7398550
10 November 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7344083
29 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7084845
21 January 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6892790
25 November 2019
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6862815
29 October 2019
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840156
10 July 2019
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6744325
18 December 2018
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6599634
10 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6537032
20 August 2018
Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6518059
20 August 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6518100
13 June 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6443112
21 March 2018
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6376049
9 November 2017
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6303497
18 June 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6179491
26 October 2016
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6029778
13 August 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5973302
13 August 2016
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5975552
23 February 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5820761
11 January 2016
Administrative Inspection · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5794933
18 December 2015
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5784306
29 October 2014
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5013714
13 May 2014
Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4857499
12 May 2014
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4857448
26 July 2012
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4392124
19 July 2012
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4383988
13 July 2012
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4377466
12 July 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4382925
17 May 2012
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4314122
15 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4208698
10 February 2011
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3943328
24 November 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3898032
24 November 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3898036
22 November 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3900258
22 November 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3900285
28 November 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3374708
28 November 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3374713
30 October 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3354381
1 April 2008
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3175088
8 January 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3126583
19 November 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3100787
21 June 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3348043
6 March 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2882522
26 September 2006
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2787934
26 September 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2787946
26 September 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2789647
24 February 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2591148
3 January 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2559828
13 December 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2550399
10 June 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2386155
7 June 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2386165
1 April 2005
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2324297
19 November 2004
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2244214
31 March 2004
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2034527
23 March 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2029556
22 October 2003
Examination of Repairs · Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1934349
27 February 2003
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1750140
19 August 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663174
27 February 2002
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1490898
23 February 2001
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1437866
17 August 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1365917
4 July 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 114783
31 March 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1461273
28 February 2000
Re-Inspection · Drydock Extension
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384373
14 July 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1098608
9 July 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 115568
9 July 1999
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1466059
3 March 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 802182
25 January 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1122965
3 March 1998
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1383792
24 February 1998
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1464097
13 February 1998
Hull Examination · Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1460157
12 December 1997
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1117083
9 December 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 126184
21 October 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 96772
17 September 1997
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775956
9 September 1997
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1441296
25 June 1997
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1445233
21 May 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1100697
16 January 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099582
18 July 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462518
4 June 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1183708
16 May 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 669679
15 May 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1086285
13 May 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 214763
29 February 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 871868
11 May 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 922268
3 March 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 856270
12 May 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1170582
2 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1168543
16 April 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169239
9 November 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 851222
2 November 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 840663
22 October 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156378
30 April 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1149207
30 April 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1157779
13 April 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 832996
3 September 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1134317
3 September 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1265769
10 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952511
31 March 1992
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 952076
30 March 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 125934
27 March 1992
Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 945339
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 December 2025
No resolution recorded
Controls [for fixed CO2 systems] shall be installed in an accessible location outside the space protected.
Pressure switches were installed inside the protected engine room space. System modification to be addressed IAW decision from Marine Safety Center (MSC) and prior
2026 hull credit. 46 CFR 181.20-10(b)(3)
Action required: 705 - Other - as specified
Due 9 December 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 December 2025
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H. Doors in bulkheads required to be Class A-60, A-30, or A-15 shall be of hollow steel in equivalent metal construction solidly filled with approved structural insulation capable of meeting the requirements for a class A-15 bulkhead. Engine room door could not be confirmed to meet A-15 fire boundary. Replace door to satisfaction of attending marine inspector and prior to 2026 hull credit. 46 CFR 177.10-5, 46 CFR 72.05-25.
Action required: 705 - Other - as specified
Due 9 December 2025
Resolved 6 March 2026
Resolution: Inspected engine room fire door and found consistent construction with fire doors in other boundaries. Domestic fire doors do not require type approval. Door appears to be two 1.5mm steel panels with insulation between and are original to the construction
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2025
Resolved
At each initial and subsequent inspection for certifications and reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. Complete and simple instructions must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Marine Inspector observed failed pressure switches indicated on inspection report from Fire Equipment Inc dated 29Oct2025. Comments on the report stated pressure switches did not shut down main engines. Owner/operator to conduct additional servicing/testing of the system to verify pressure switches shut down vessel’s main diesel engines to the satisfaction of attending Marine Inspector. Provide system drawings and schematics for on board system. 46 CFR 176.25-25(Old T),
46 CFR 181.20-15(Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 November 2025
Resolved 9 December 2025
Resolution: Fire technician performed necessary tests. Pressure switches operating satisfactory. Instuctions and schematics posted in proper locations.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. Several areas of localized pitting was found in the #2 void port side forward. O/O to submit a temporary repair proposal to cognizant [name withheld] temp repair within 14 days. Permanent repairs are to then be made prior to next credit hull exam.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 8 April 2026
Resolution: Coating accepted to arrest further corrosion. Continued monitoring at annual ISEs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. Areas of corrosion and wastage were found in the way of the starboard blackwater watertight bulkhead penetration. O/O to submit repair proposal to cognizant [name withheld] repairs are to then be made prior to next credit hull exam. 46 CFR 182.40-1
Action required: 705 - Other - as specified
Due 25 November 2025
Resolved 30 March 2026
Resolution: Two inserts installed and inspected satisafactorily.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 November 2025
Resolved
All vessels shall be provided with a suitable steering apparatus. Vessel’s starboard rudder hydraulic actuator leaking hydraulic fluid. O/O to repair/replace hydraulic actuator prior to receiving next credit hull exam. 46 CFR 182.30-1.
Action required: 705 - Other - as specified
Due 25 November 2025
Resolved 8 April 2026
Resolution: Hydraulic actuator renewed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2025
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessel’s bilge pick up pipe right after strainer in #6 void and bilge line coupling in #3 void near forward bulkhead was heavily wasted. O/O to repair/replace bilge pick up lines to satisfaction of attending marine inspector prior to receiving credit hull exam. 46 CFR 182.25-1
Action required: 705 - Other - as specified
Due 25 November 2025
Resolved 8 April 2026
Resolution: Descaled bilge pipe and tested. Current condition accepted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 November 2025
Resolved
Penetrations of required watertight decks and bulkheads are prohibited except when each penetration is accomplished using an acceptable metal fitting, welded or otherwise attached to bulkhead by accepted methods, and an acceptable metallic shutoff valve is installed adjacent to the through hull fittings. Blackwater lines penetrating watertight bulkhead between void #6 and lazarette to be fitted with metallic shutoff valves. O/O to submit repair proposal to cognizant OCMI detailing inclusion of metallic shut off valves to the piping system, prior to receiving next credit hull exam.
46 CFR 182.40-1
Action required: 705 - Other - as specified
Due 25 November 2025
Resolved 8 April 2026
Resolution: Piping renewed and metalic shutoff valve installed at MTWB.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 November 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly checks on portable fire extinguishers were not completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2025
Resolved 31 December 2025
Resolution: O/O provided objective evidence showing monthly fire extinguisher inspections were completed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 October 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Operation of the fire main system and checking of the pressure at the most remote and highest outlets. When fire main was energized, the pipe burst while under pressure in the #3 void. Apply permanent repairs to fire main to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2024
Resolved 4 November 2024
Resolution: Vessel made appropriate repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Port forward engine oil pressure gauge at operating station was reading improper pressure level.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2024
Resolved 4 November 2024
Resolution: Pressure gauge was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 October 2024
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. Vessel's fire control plan is missing all required information except for fire protection/emergency equipment. Update plan to reflect required information/equipment that pertains to vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2024
Resolved 14 January 2025
Resolution: Revised fire control plan approved and onboard vessel.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 January 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of a vessel in accordance with the terms of the Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Pitting was found on the over head of the vessel's number 2 void, including approximately 10 small holes through the deck where the forward part of the superstructure meets the weather deck. Provide repair proposal and make effective repairs to the satisfaction of the attending Marine Inspector. 46 CFR 116.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2024
Resolved 1 March 2024
Resolution: 3" circular inserts accepted, visually inspected satisfactorily inside weathertight superstructure.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 January 2024
Resolved
he construction and arrangement of a vessel must allow the safe operation of a vessel in accordance with the terms of the Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Goose-neck for aft ballast tank vent on the starboard side of the aft weather-deck, found with pinhole wastage where the standpipe meets the deck. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 116.100(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2024
Resolved 1 March 2024
Resolution: No crack inspected in weld after paint was removed. O/O to weld support bracket to prevent vibration and damage. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 January 2023
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. Excessive pitting was observed in the #6 void, port #4 bulkhead stiffener from centerline. Two substantial pits were observed with a depth of .270 and .210. Vessel representative shall make a final determination through visual inspection of the hull or by other NDT methods to determine plate thickness.
Action required: 705 - Other - as specified
Due 19 January 2023
Resolved 10 January 2024
Resolution: Verified area fitted with 1/2" + 3/8" plate with primer and corrosion arrested internally. No corossion identified, NDT not required at this time.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2020
Resolved
All escape hatches shall be marked on both sides using at least 1" letters "Emergency Exit, Keep Clear". Engine room emergency escape hatch was not marked on either side. Crew mounted placards during the inspection.
46 CFR 185.30-15
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2020
Resolved 29 October 2020
Resolution: Placards mounted on both sides of hatch during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2020
Resolved
All electrical equipment must be clearly marked and identified. The port and starboard steering motor breakers were marked with the wrong amperage. (see pictures)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 11 November 2020
Resolution: Vessel rep provided steering pump breaker proper labled placards.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 November 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H (Passenger Vessels) of this chapter. The application of these requirements to specific vessels shall be as determined by the Officer in Charge, Marine Inspection.
Vessel's machinery space on the main deck and on the second deck do not meet the fire control boundary requirements of A-60 boundaries. Submit plans to OCMI for modifications to the spaces to meet structural fire protection requirements IAW: SUBCHAPTER H & NVIC 9-97.
46 CFR 177.10-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2019
Resolved 21 May 2020
Resolution: New SFP completed satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 October 2019
Resolved
Exhaust piping shall be led to the point of escape with
a minimum number of bends or elbows. It shall be
gastight throughout its length and shall be properly
supported by non-combustible hangers or blocks.
Marine inspector noted evidence of exhaust leak in
void #6 via visual condition of lagging and through
smell while machinery was online. Locate source or
exhaust leak and make repairs as nessecary to
resolve issue.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2019
Resolved 5 February 2020
Resolution: Witnessed a satisfactory welding around the exhaust.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 October 2019
Resolved
Provide mitigation plan to prevent personnel exposure
to exhaust hazard in #6 void space to remain in effect
until deficiency #1 is corrected.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: Mitigation plan provided. Added to documents.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2019
Resolved
All escape hatches and other emergency exits shall be
marked on both sides using at least 1-inch letters:
"Emergency Exit, Keep Clear", unless such markings
are deemed unnecessary by the Officer in Charge,
Marine Inspection. Fwd engine room escape hatch is
not properly marked on engine room side. Mark hatch
as required.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: Emergency escape properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2019
Resolved
All vessels except non-self-propelled vessels shall be
provided with suitable steering apparatus. Upper
rudder post plate on starboard steering arm is wasted
and visually bent due to weakened metal. Replace
stbd upper rudder post plate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2019
Resolved 4 February 2020
Resolution: Rudder post plate was replaced.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 October 2019
Resolved
Class A bulkheads shall be so insulated with approved
structural insulation, bulkhead panels, or deck
covering that the average temperatures on the
unexposed side would not rise more than 250 °F.
Insulation not properly installed in aft stbd corner of
engine room. Install missing insulation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 12 November 2019
Resolution: Missing insulation replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 October 2019
Resolved
A battery charger intended for connection to a
commercial supply voltage shall have an ammeter that
is readily visible shall be included in the battery
charger circuit. Battery charger on fwd stbd bulkhead
in engine room has a non operational ammeter that is
not properly mounted to the charger housing. Provide
operational ammeter as required.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 12 November 2019
Resolution: Battery charger meter replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 December 2018
Resolved
Each hatch cover must have a securing device. Lazarette hatch cover missing securing device.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 December 2018
Resolution: Securing device installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2018
Resolved
Engine exhaust piping shall be gastight throughout its length. Stbd forward exhaust was found with excessive pitting at the point where it meets the side shell. Make gastight. 46CFR182.20-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2019
Resolved 2 January 2019
Resolution: Pitting cleaned out and re-welded, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 December 2018
Resolved
At each vessel inspection, all observed hazardous situations must be corrected. In lazarette, stbd quarter has significant inset, above which is a crack in the side shell showing daylight. Make side shell watertight. On port quarter, one cracked weld marked for repair. 46CFR115.830
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2019
Resolved 8 January 2019
Resolution: Crack welded, all sat.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 December 2018
Resolved
At each inspection, the marine inspector may require that man overboard/fire drill be held under simulated emergency conditions. Unable to conduct drills due to strong winds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2019
Resolved 8 January 2019
Resolution: Satisfactory man overboard and fire drills conducted.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018
Resolved
Vsl is broadcasting no IMO #, not broadcasting a Call Sign, smaller than expected vessel length and no static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 November 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2018
Resolved
Remove & replace the wasted pipe on the forward generator raw water intake line. Prove proper operation of both generators while operating underway. Conduct sea trials to prove all components are in working order.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2018
Resolved 21 August 2018
Resolution: Removed & replaced the wasted pipe on the forward generator raw water intake line. Proved proper operation of both generators while operating underway. Conducted sea trials to prove all components were in working order.
Engineering › Freshwater Generation System › Piping
Issued 21 March 2018
Resolved
Several wasted pipes discovered in exhaust compartment (void #6). Issued requirement to make permanent repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2018
Resolved 13 April 2018
Resolution: Made permanent repairs on the wasted pipes.
Construction/Loadline › Hull › Hull Plating
Issued 21 March 2018
Resolved
Significant inset was discovered on the port side of the lazerette, issued requirement to make permanent repairs.
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 18 December 2018
Resolution: Permanent repair made, all sat.
Operations/Management › Vessel Activity › Underway
Issued 21 March 2018
Resolved
Vessel replaced the port outboard shaft and realigned to gear, issued requirement to conduct underway sea trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2018
Resolution: Conducted underway sea trials with satisfactory results.
Engineering › Feedwater/Condensate Water System › Piping
Issued 21 March 2018
Resolved
Repair cracked weld on starboard inboard raw water pipe intake for the engine at the forward bulkhead in void #6. Conduct additional rounds every 30 minutes to ensure condition does not worsen.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 17 April 2018
Resolution: Weld was repaired and air lance/soap tested. All sat.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 9 November 2017
Resolved
Troubleshoot and repair stbd inboard MDE over speed alarm.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 21 November 2017
Resolution: Repaired sensor in alarm. All sat.
Electrical › Electric Supply System (service) › Battery Charger
Issued 9 November 2017
Resolved
Repair or renew battery charger in pilothouse.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 30 November 2017
Resolution: Battery charger was replaced with new unit.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 November 2017
Resolved
Provide cover for distribution panel in pilothouse.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 21 November 2017
Resolution: Replaced distribution panel cover.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 November 2017
Resolved
Provide platform on MOB ladder.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2017
Resolved 30 November 2017
Resolution: Platform on MOB ladder was added.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 November 2016
Resolved
Crop and renew wasted bulkhead IWO sewage tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2016
Resolution: Approx area of 20" X 30" aluminum plate was croppped out and renewed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 November 2016
Resolved
Repair or replace wasted salt water overboard piping for generators.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2016
Resolution: Salt water piping was replaced in kind.
Engineering › Freshwater Generation System › Piping
Issued 9 November 2016
Resolved
Repair or replace wasted fresh water piping in exhaust void.
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 28 November 2016
Resolution: Fresh water piping was replaced in kind.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 October 2016
Resolved
During MOB drill rescue platform was inadequate. Vessel to provide satisfactory arrangements to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2016
Resolution: Received photograph from vessel rep showing adequate modifications made to the rescue platform.
Construction/Loadline › Structures › Door
Issued 26 October 2016
Resolved
Engine room door does not latch.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Engine door handle assembly was replaced with new.
Construction/Loadline › Structures › Door
Issued 26 October 2016
Resolved
Stair tower doors have carpet installed on the threshold and doors do not self close.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Stair tower carpet was removed from both door thresholds and properly close.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 26 October 2016
Resolved
Provide instructions for fixed firefighting arrangements.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Instruction were provided for fixed fire fighting system.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 26 October 2016
Resolved
Make pressure vessel available for inspection and replace relief valve.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Pressure vessel was made available for inspection, conducted satisfactory internal visual inspection. Tested new safety relief, test sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 October 2016
Resolved
Make permanent repairs to A/C raw water line in fuel void. A/C not to be used until repaired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: A/C piping and bulkhead coupling was replaced in kind and satisfactorily tested.
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 October 2016
Resolved
Compass light inoperable. Vessel restricted to daylight operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Compass light was inspected and found to be operational.
Documentation › Certificates/Documents › Stability Letter
Issued 26 October 2016
Resolved
Provide current stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Current stability letter was provided.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 26 October 2016
Resolved
Make exhaust space safe and available for inspection. High levels of CO2 were found indicating an exhaust leak. Repair exhaust leak.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Exhaust void was made available for inspection.
Engineering › Compressed Air System (control) › Valve
Issued 13 August 2016
Resolved
Vessels propulsion controls (pnuematic) inop for outboard starboard engine (locked in forward). Repair and test to the satisfaction of MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2016
Resolution: New valve has been installed and tested by attending [name withheld].
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 August 2016
Resolved
02 Windows damaged due to collision. Replace to the satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2016
Resolution: Windowns have been replaced and inspected. SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 January 2016
Resolved
Crack was found in port fwd engine exhaust in void #6. Repair. 46CFR182.15-20(d)
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 21 January 2016
Resolution: Exhaust pipe repaired.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 20 January 2016
Resolved
Have non-conductive mat in front of switchboard. (Corrected on the spot)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 20 January 2016
Resolution: corrected on the spot.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 18 December 2015
Resolved
THE VESSEL'S 50-PERSON INFLATABLE BUOYANT APPARATUS HAS BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL'S ROUTE IS LIMITED TO NOT MORE THAN ONE NAUTICAL MILE FROM SHORE UNTIL THE IBA HAS BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 February 2016
Resolved 3 February 2016
Resolution: VSL changed route to LBS.
Lifesaving › Lifefloat › Serviceable
Issued 29 October 2014
Resolved
3 life floats were found with rotten and wasted lifeline straps. Capacity is reduced to 72 on limited coastwise route, and 144 on route between 1 and 3 nm from shore. Provide new life floats or IBA.
Action required: 705 - Other - as specified
Due 12 November 2014
Resolved 3 February 2016
Resolution: VSL changed route to LBS.
Lifesaving › Lifebuoys › Serviceable
Issued 29 October 2014
Resolved
2 life rings on bridge have broken life lines or are unserviceable. replace or repair.
Action required: 705 - Other - as specified
Due 12 November 2014
Resolved 12 November 2014
Resolution: 2 new life rings installed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 October 2014
Resolved
Overhead and Bulkheads in Engineroom are "A60" boundary and require insulation. Insulation above Stbd generator, and aft BLKD were missing. Repair to original.
Action required: 705 - Other - as specified
Due 26 November 2014
Resolved 26 November 2014
Resolution: A60 boundry has been properly installed.
Fire Fighting › Fire Main › Pressure
Issued 29 October 2014
Resolved
Fire pump is required to have a pressure gage fitted at the pump outlet. Fire main does not have a gage. Provide a gage at the pump outlet.
Action required: 705 - Other - as specified
Due 12 November 2014
Resolved 12 November 2014
Resolution: New pressure gauge installed and tested.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 October 2014
Resolved
Survival craft and epirb maintenance and testing must be logged. Logs are not maintained. provide required logs.
Action required: 705 - Other - as specified
Due 12 November 2014
Resolved 12 November 2014
Resolution: Survival craft maintence and EPIRB tested and logged
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 May 2014
Resolved
Port aft engine ECU deutsch engine control harness connection plug is broken. Engine is inoperable. Repair broken connector and test engine operation.
Action required: 705 - Other - as specified
Due 27 May 2014
Resolved 15 May 2014
Resolution: New emgine control harness connection plug installed and ran sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 July 2012
Resolved
Change vessel's name on hull, documents, licenses, lifesaving equipment, AIS, logs, plans, etc to correspond to recently issued Certificate of Documentation.
Due 2 August 2012
Resolved 27 July 2012
Resolution: All items corrected sat.
Construction/Loadline › Hull › Hull Plating
Issued 13 July 2012
Resolved
Vessel sustained damage to port side hull plating above the waterline caused by contact with pier that punctured through the hull approximately 12 inches long by 2.5 inches tall penetrating into the #2 void compartment. Vessel is required to make permanent repairs (crop and renew damaged plate in kind). Make repairs to the satisfaction of attending Marine Inspector prior to taking passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2012
Resolved 13 July 2012
Resolution: Damaged area of aluminum hull plating was cropped and renewed to the satisfaction of attending Marine Inspector. Visual inspection and hose test was conducted and found to be satisfactory.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 May 2012
Resolved
Provide certificate of documentation showing name change to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2012
Resolved 31 May 2012
Resolution: Application made to VDOC.
Engineering › Fuel Oil Service System › Valve
Issued 17 May 2012
Resolved
Repair inoperative fuel shut-off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2012
Resolved 31 May 2012
Resolution: Repairs made sat.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 17 May 2012
Resolved
Provide approval for newly installed carpet.
Due 17 June 2012
Resolved 31 May 2012
Resolution: Approvals provided sat.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 17 May 2012
Resolved
Inspect installation of IBA
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 15 June 2012
Resolution: Installed IBA for 25 persons on the upper deck aft. Inspectec SAT.
Documentation › Certificates/Documents › Stability Letter
Issued 15 December 2011
Resolved
The vessel's owner/operator has not requested an initial or updated stability letter or has not certified compliance with the revised stability criteria for assumed average weight per person (AAWPP) of 185 pounds. Based upon a weight ratio calculation, the vessel's capacity is therefore limited to: 307 persons (passengers and crew). 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 16 December 2011
Resolution: Received updated stability letter from MSC.
Documentation › Logs/Records › Logbook (official)
Issued 10 February 2011
Resolved
Drills, Training, Emergency equipment testing, monthly EPIRB testing has not been properly documented. Provide documented proof in way of official log book & lifesaving equipment maintenance & testing record. 46CFR185 Operations, as applicable to existing vessels. 30 days to complete
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 19 May 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 February 2011
Resolved
Bar/Food service area on main deck in unsanitary condition. Beverege dispensing system in need of sanitation, re-new water filter under sink, ice coolers dirty, bevereges located in bin cooler covered with dust/debris. Sanitize all storage, working surfaces & decks. 46 CFR 176.25-45 old T & 46 CFR 176.818. 30 days to complete.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 February 2011
Resolved
Compressed gas cylinders for beverage service system not constrained & are potential missle hazard. A gas cylinder must be securley fastned, supported, & protected from damage so as not to hazard the vessel or persons being transported. 46 CFR 185.100 as applicable to existing vessels. 30 days to complete.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 February 2011
Resolved
Electrical outlet covers missing in bar area. Install proper covers on all outlet boxes. 46 CFR 183.01-15 (a). 30 days to complete.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Lifesaving › Lifefloat › Serviceable
Issued 10 February 2011
Resolved
Lifefloats in reduced state of readiness. Replace worn & deteriorated lifefloat & sea painter lines; Replace all wood dunnage seperating floats; Properly secure paddles & interior netting so not tangled with neighboring raft in stack, several rafts stacked so paddles are situated under netting, turn rafts right side up. 46 CFR 180 as applies to existing vessels. 30 days to complete
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 19 May 2011
Lifesaving › Lifefloat › Float-free Link
Issued 10 February 2011
Resolved
Lifefloat weak-links are missing CG approval tags. Float free link must be certified to meet 46 CFR 160.073 in subchapter Q. Ensure link is properly attached to floats & adequately secure point on vessel.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 February 2011
Resolved
Lifejackets in maindeck fwd storage area. Child & adult jackets stored together. Storage container identifies only children's PFD's. Make provisions to properly mark storage area & keep children & adult PFD's seperated to avoid confusion. 46 CFR 180.78 as applies to exisiting vessels. 30 days to complete
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Electrical › Electric Supply System (service) › Battery Charger
Issued 10 February 2011
Resolved
Port side engineroom battery charge missing indicating needle, install new indicating device. 46 CFR 183.350 (f) as applies to existing vessels. 30 days to complete. It may be written the charger is good but it still needs an indicating device.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 19 May 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 February 2011
Resolved
Emergency lighting has missing lights or inoperable lights & needs to be properly labeled. Make proper repairs, properly identify emergency lights, & satisfactorily test in presence of CG Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2011
Resolved 17 February 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 10 February 2011
Resolved
Unprotected or missing light fixtures on main deck and 02 deck, replace or install as necessary. 46 CFR 183.01-15 Old "T"
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 February 2011
Resolved
Exhaust piping leaking in muffler compartment. Make suitable repairs, test to satisfaction of CG Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2011
Resolved 17 February 2011
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 February 2011
Resolved
Fuel oil valves servicing furnace missing handles. Re-install handles.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 February 2011
Resolved
Remove flammable materials from under switchboard & remove spare parts crates from top of batteries boxes. Find suitable storage for these items away from electrical service system. 46 CFR 183.01-5 Old "T"
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 17 February 2011
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 February 2011
Resolved
No indications EPIRB was being tested monthly. Provide documentation of future monthly tests for newly installed EPIRB. 46 185.25-20 Old "T"
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 19 May 2011
Engineering › Bilge Water Management System › Not Operational
Issued 30 October 2008
Resolved
high level alarm for engineroom inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2008
Resolved 3 November 2008
Resolution: Repaired and tested sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 November 2007
Resolved
resecure electrical junction boxes on forward main deck.
Due 30 November 2007
Resolved 4 December 2007
Resolution: Secured sat.
Stability › Watertight Integrity › General
Issued 19 November 2007
Resolved
Re-weld bulkhead penetration in the #4 forward bulkhead stbd side.
Due 30 November 2007
Resolved 4 December 2007
Resolution: re-welded sat.
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2007
Resolved
repair electrical cable conduit.
Due 30 November 2007
Resolved 4 December 2007
Resolution: repaired sat.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 November 2007
Resolved
Replace both flexible discharge hoses for the raw water disharge side for both port MDE's.
Due 30 November 2007
Resolved 4 December 2007
Resolution: hoses replaced sat.
Fire Fighting › Fire Hoses › Condition
Issued 19 November 2007
Resolved
Re-install both fire hose hangars om main deck.
Due 30 November 2007
Resolved 4 December 2007
Resolution: completed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 November 2007
Resolved
repair fire door latch.
Due 30 November 2007
Resolved 4 December 2007
Resolution: repaired sat.
Fire Fighting › Fire Main › Condition
Issued 19 November 2007
Resolved
repair leak in the fire main aft main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2007
Resolved 20 November 2007
Resolution: fire main repaired sat.
Engineering › Steering Gear System › Rudder
Issued 26 September 2006
Resolved
Make repairs to and prove proper operation of hydraulic steering system and jockey bar.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2006
Resolved 28 September 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 March 2006
Resolved
Secure lagging on stbd side exhaust in #6 void.
Due 2 April 2006
Resolved 4 April 2006
Engineering › Fuel Oil Service System › Hose
Issued 3 March 2006
Resolved
Replace chafing gear and ensure proper condition of hose forward of the fwd generator.
Due 2 April 2006
Resolved 4 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 March 2006
Resolved
Complete repairs on longitudnal framing and associated webbing aft of the sewage tank in the lazarette.
Due 2 April 2006
Resolved 4 April 2006
Communications › Radio Communications › EPIRB
Issued 13 December 2005
Resolved
Battery out of date.
Due 16 December 2005
Resolved 30 December 2005
Resolution: Corrected sat.
Communications › Radio Communications › EPIRB
Issued 13 December 2005
Resolved
Hyrdostatic release out of date.
Due 16 December 2005
Resolved 30 December 2005
Resolution: Corretected sat.
Communications › Radio Communications › EPIRB
Issued 13 December 2005
Resolved
On/off switch for EPIRB is broken.
Due 16 December 2005
Resolved 30 December 2005
Resolution: Corrected sat.
Lifesaving › Lifebuoys › Serviceable
Issued 13 December 2005
Resolved
Replace lifering outside pilot house.
Due 30 December 2005
Resolved 30 December 2005
Resolution: Corrected sat.
Engineering › Steering Gear System › Bracket/Clamp
Issued 13 December 2005
Resolved
Bracket for hydrualic steering ram broken.
Due 30 December 2005
Resolved 30 December 2005
Resolution: Corrected sat.
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 December 2005
Resolved
Hydraulic hose has split in lazz.
Due 30 December 2005
Resolved 30 December 2005
Resolution: Corrected sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 November 2004
Resolved
Provide repair proposal to address fractured welds & structural members, and localized pitting in lazarette and #6 void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2004
Resolved 7 December 2004
Resolution: Received proposal for temporary repairs to structural issues in lazarette and #6 void. Permanent repairs to be made in drydock over the winter. The vessel will not be used after 01Jan2005 until permanent repairs are examined by a Marine Inspector.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 November 2004
Resolved
Make permanent repairs to fractured welds on longitudinal and transverse frames in lazarette and #6 void.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 29 March 2005
Resolution: see narrative
Construction/Loadline › Penetrations › Pipe Flange
Issued 19 November 2004
Resolved
Renew two wasted penetrations on fwd transverse bulkhead in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2005
Resolved 15 December 2004
Resolution: Examined renewed penetrations. All sat.
Engineering › Steering Gear System › Bracket/Clamp
Issued 19 November 2004
Resolved
Renew broken port rudder stop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2004
Resolved 15 December 2004
Resolution: Examined repair. All sat.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 November 2004
Resolved
Repair broken latch on engine room door.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2004
Resolved 15 December 2004
Resolution: Examined and tested new door latch. All sat.
Construction/Loadline › Hull › Bottom Plating
Issued 19 November 2004
Resolved
Make permanent repairs to localized pitting on interior of bottom plating on port/stbd of keel IWO ladder in #6 void.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 29 March 2005
Resolution: see narrative
Engineering › Steering Gear System
Issued 31 March 2004
Resolved
Install cotter pins on steering rams prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 31 March 2004
Resolution: Installed cotter pins.
Engineering › Fuel Oil Service System
Issued 31 March 2004
Resolved
Reclamp fuel pipe and filter for upper heater prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 31 March 2004
Resolution: Reclamped fuel pipe and filter for upper heater prior to carrying passengers.
Engineering
Issued 31 March 2004
Resolved
Replace access door on upper heater prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 31 March 2004
Resolution: Replaced access door on upper heater prior to carrying passengers.
Fire Fighting › Fire Hydrants › Condition
Issued 31 March 2004
Resolved
Repair fire station valve and prove proper operation.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 14 April 2004
Resolution: Repaired fire station valve and proved proper operation.
Electrical › Electric Supply System (service)
Issued 31 March 2004
Resolved
Remove dead ended wiring from lower heater room.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 14 April 2004
Resolution: Dead ended wire is removed from lower heater room.
Electrical › Electric Supply System (service)
Issued 31 March 2004
Resolved
Replace burned electric coil in controller in lower heating room.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 14 April 2004
Resolution: Replaced burned electric coil in controller in lower heating room.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 31 March 2004
Resolved
Prove proper operation of main deck door leading up stairwell.
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 8 July 2004
Resolution: Witnessed satisfactory test of self-closing door.
Engineering › Fuel Oil Service System
Issued 31 March 2004
Resolved
Replace/Install proper 30/30 mesh in fuel tank vent.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 14 April 2004
Resolution: Replaced 30/30 mesh in fuel tank vent.
Engineering › Bilge Water Management System
Issued 31 March 2004
Resolved
Provide Bilge instructions for engine room.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 14 April 2004
Resolution: Instructions for bilge system are in place.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 March 2004
Resolved
Find and repair port side exhaust leak in the #6 void space and replace lagging. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2004
Resolved 31 March 2004
Resolution: Replaced flange gasket and reinstalled lagging.
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Reweld side shell at the chine, starboard side, aft corner in the lazzerette. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 April 2004
Resolved 31 March 2004
Resolution: Welding repair complete.
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Reweld port side I-beam under hydro ram in the lazzerette. LEGACY COMPONENT DESC: Girder
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 April 2004
Resolved 31 March 2004
Resolution: Welding repair complete.
Stability › Watertight Integrity
Issued 22 October 2003
Resolved
Prior to operating make proper repairs to port aft corner as discussed with BHC welder (Matt).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2003
Resolved 1 December 2003
Construction/Loadline › Hull
Issued 22 October 2003
Resolved
Prior to operating make proper repairs to cracked long. on port side at steering ram connection point. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2003
Resolved 1 December 2003
Construction/Loadline › Structures
Issued 22 October 2003
Resolved
Prior to operating install gasket in lazzerette scuttle. LEGACY COMPONENT DESC: Scuttle
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2003
Resolved 1 December 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 February 2003
Resolved
Prior to operating complete annual service on Portable and Fixed Fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2003
Resolved 14 March 2003
Fire Fighting › Fire Main
Issued 27 February 2003
Resolved
Prior to operating prove proper operation of Fire Main system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2003
Resolved 14 March 2003
Lifesaving › Rigid Liferafts
Issued 27 February 2003
Resolved
Vessel is limited to within 1 mile from shore until Lifefloats are properly stowed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 14 March 2003
Lifesaving › Rigid Liferafts
Issued 27 February 2003
Resolved
Replace painter line on portside lifefloat above wheelhouse. LEGACY COMPONENT DESC: Painter
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 14 March 2003
Stability › Watertight Integrity
Issued 27 February 2003
Resolved
Replace scuttle gaskets for lazerette and void space 4.
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 14 March 2003
Electrical › Electrical Distribution System (service)
Issued 27 February 2003
Resolved
Install wiresplice in proper junction box in void space 4. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 14 March 2003
Operations/Management › Pollution
Issued 27 February 2003
Resolved
Clean sewage from lazerette bilge to facilitate CG internal exam to lazerette space. LEGACY COMPONENT DESC: Control of Discharge of Sewage
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 14 March 2003
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 February 2003
Resolved
Vessel is limited to 352 persons until 1 Adult PFD is provided. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 15 December 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 27 February 2003
Resolved
Make proper repairs to stbd forward handrail between main and second deck LEGACY COMPONENT DESC: Hand Grab
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 14 March 2003
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 February 2003
Resolved
Provide proper pubs and charts for vessel operating area.
Action required: 705 - Other - as specified
Resolved 27 February 2003
Construction/Loadline › Penetrations
Issued 27 February 2002
Resolved
Submit a detail repair proposal for cracks in after engine room bulkhead and deck in way of main engine exhaust penetrations.
Condition: Design Flaw
Due 27 March 2002
Resolved 25 April 2002
Engineering › Steering Gear System
Issued 27 February 2002
Resolved
Re-weld broken bracket for hydraulic steering ram in lazarette.
Due 27 March 2002
Resolved 25 April 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 27 February 2002
Resolved
Remove fuel/water from fuel tank compartment and tighten union.
Due 27 March 2002
Resolved 25 April 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 February 2002
Resolved
Renew brackets for fixed halon fire fighting system.
Due 27 March 2002
Resolved 25 April 2002
Construction/Loadline › Hull
Issued 27 February 2002
Resolved
Dye penetrate test cracks to bottom hull plating located below the port main engine foundation.
Due 27 March 2002
Resolved 25 April 2002
Electrical
Issued 23 February 2001
Resolved
Replace broken light switch cover in storage room, 2nd deck aft.
Condition: Unknown
Due 26 March 2001
Resolved 3 April 2001
Accommodation/Occupational Safety
Issued 23 February 2001
Resolved
Make proper repairs to stern rails and bow rails.
Condition: Unknown
Due 26 March 2001
Resolved 3 April 2001
Accommodation/Occupational Safety
Issued 23 February 2001
Resolved
Make proper repairs to door latch, 2nd deck, port side aft.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Electrical
Issued 23 February 2001
Resolved
REPLACE MISSING LIGHT COVER IN STBD STAIRWAY AND STBD BOW, FWD OF HOUSE.
Condition: Unknown
Due 26 March 2001
Resolved 3 April 2001
Accommodation/Occupational Safety
Issued 23 February 2001
Resolved
Replace missing vent screens (2) from burner room to storage room, 2nd deckaft.
Condition: Unknown
Due 26 March 2001
Resolved 3 April 2001
Unknown
Issued 23 February 2001
Resolved
Provide proper gauge on air receiver and prove proper operation of relief valves.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Construction/Loadline
Issued 23 February 2001
Resolved
Make proper repairs to hole in port bow gunwhale.
Condition: Unknown
Due 26 March 2001
Resolved 3 April 2001
Construction/Loadline
Issued 23 February 2001
Resolved
Prove proper operation of forepeak bilge system.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Unknown
Issued 23 February 2001
Resolved
Prove proper operation of P.A. system.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Electrical
Issued 23 February 2001
Resolved
Replace missing electrical junction box covers (2) in #3 void.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Construction/Loadline
Issued 23 February 2001
Resolved
Make proper repairs to cracked frame in void #6.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Electrical
Issued 23 February 2001
Resolved
Replace missing electrical outlet covers inboard of inboard stbd engine.
Condition: Unknown
Due 31 March 2001
Resolved 3 April 2001
Lifesaving
Issued 28 February 2000
Resolved
PROVIDE AN ACCEPTABLE ARRANGEMENT TO ALLOW THE DECKHANDS ACCESSIBILITY TO RETRIEVE A PERSON FROM THE WATER.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Construction/Loadline
Issued 28 February 2000
Resolved
8. PROPERLY REPAIR/REPLACE THE BROKEN AND MISSING DOGS ON THE PORT AND STARBOARD LOADING DOORS.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Construction/Loadline
Issued 28 February 2000
Resolved
REMOVE DEBRIS FROM THE BILGE IN THE MUFFLER SPACE.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Construction/Loadline
Issued 28 February 2000
Resolved
REPAIRED THE LEASH FOR THE FOREPEAK.
Condition: Unknown
Due 28 February 2000
Resolved 2 March 2000
Lifesaving
Issued 28 February 2000
Resolved
2. REPLACED TWO MISSING ADULT LIFEJACKETS.
Condition: Unknown
Due 28 February 2000
Resolved 2 March 2000
Lifesaving
Issued 28 February 2000
Resolved
REPAIR THE LIFE FLOAT ATTACHMENTS (INCORRECTLY HOOKED UP).
Condition: Unknown
Due 28 February 2000
Resolved 2 March 2000
Fire Fighting
Issued 28 February 2000
Resolved
REPLACED THE MISSING FOG NOZZLE ON THE #2 FIRE HOSE.
Condition: Unknown
Due 28 February 2000
Resolved 2 March 2000
Documentation
Issued 28 February 2000
Resolved
PROPERLY LABEL THE HAILING PORT ON THE STERN.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Accommodation/Occupational Safety
Issued 28 February 2000
Resolved
PROPERLY REPAIR THE VENT BALL FOR THE COMPARTMENT VENT, PORT BOW.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Lifesaving
Issued 28 February 2000
Resolved
PROPERLY REPAIR THE LIFEFLOAT BASKET FOR THE AFT UPPER LIFEFLOAT.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Fire Fighting
Issued 28 February 2000
Resolved
PROVIDE A SERVICING REPORT FOR THE FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Electrical
Issued 28 February 2000
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHT ON THE SECOND DECK STARBOARD SIDE.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Electrical
Issued 28 February 2000
Resolved
PROVIDE COVER FOR THE ELECTRICAL CONNECTIONS AND REMOVE THE WIRE NUTS ON THE CONNECTION FOR THE LIGHTS IN THE GALLEY OVERHEAD.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Accommodation/Occupational Safety
Issued 28 February 2000
Resolved
PROPERLY REPAIR THE BROKEN WINDOW, MAIN DECK PORT SIDE AMIDSHIPS.
Condition: Unknown
Due 8 March 2000
Resolved 13 March 2000
Construction/Loadline
Issued 9 July 1999
Resolved
BILGE HIGH LEVEL ALARM NOT OPERATION. ISSUED REQUIREMENT TO MAKE AN HOURLY CHECK OF THE SPACE UNTIL PROPER OPERATION PROVED TO AUS COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 July 1999
Resolved 9 July 1999
Construction/Loadline
Issued 3 March 1999
Resolved
PROVIDE HIGH LEVEL BILGE ALARM IN LAZARETTE.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Construction/Loadline
Issued 24 February 1998
Resolved
Gooseneck vents forward main deck screens wasted and holed. Renew screens as original.
Condition: Unknown
Due 5 March 1998
Resolved 30 March 1998
Accommodation/Occupational Safety
Issued 24 February 1998
Resolved
Renew cracked urinal in men's head main deck. Urinal cannot be properly sanitized. 46CFR 115.818. _x001C_
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Documentation
Issued 24 February 1998
Resolved
FCC Radiotelephony Safety Certificate Expired. Vessel limited to operationnot more than 1000 feet from land.
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Electrical
Issued 24 February 1998
Resolved
Properly label furnace and machinery space emergency shut downs.
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Engineering
Issued 24 February 1998
Resolved
Main deck furnace room fuel hose chafing against sheet metal furance cover. Properly secure fuel hose.
Condition: Unknown
Due 5 March 1998
Resolved 30 March 1998
Construction/Loadline
Issued 24 February 1998
Resolved
Tidy up muffler room and lazarette, miscellaneous debris in bilge, properlysecure pipes missing clamps.
Condition: Unknown
Due 5 March 1998
Resolved 30 March 1998
Construction/Loadline
Issued 24 February 1998
Resolved
Repair crack in main deck in way of muffler room sounding tube. and all cracks as marked in the muffler room and lazerette.
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Lifesaving
Issued 24 February 1998
Resolved
Forced hot air furnace stove pipe in disrepair. Properly secure furnace stove pipes.
Condition: Unknown
Due 5 March 1998
Resolved 30 March 1998
Construction/Loadline
Issued 24 February 1998
Resolved
Frame notched in lazarette. Properly repair frame. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Boat cable in use for electric lighting runs. Submit fire load calculations for all cable in use onboard the vessel other than armored cable.
Condition: Unknown
Due 28 February 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Properly pour all bulkhead/deck cable penetrations using accepted fire stopsystem. (fire stops)
Condition: Unknown
Due 28 February 1998
Resolved 31 March 1998
Engineering
Issued 13 February 1998
Resolved
Provide manufactures data report for new air receiver (pressure). See 46 CFR 54.
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Electrical
Issued 13 February 1998
Resolved
Provide documentation that fluorescent fixtures meet UL 595. See 46CFR 120.410.
Condition: Unknown
Due 28 February 1998
Resolved 31 March 1998
Engineering
Issued 13 February 1998
Resolved
Properly secure all fuel lines insure all flexible hose complies with 46CFR119.455 and 46CFR 56.60-25.
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
The oil fired furnaces are not enclosed by an A-60 bulkheads as indicated on the approved plans. See oil fired heater installation plan approved February 1992.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Electrical
Issued 13 February 1998
Resolved
Power ventilation shutdown switches for engineroom are located inside the space protected. (See 46 CFR 111.103-9)
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
No instructions are provided for operation of the fixed fire system at the local controls. Provide operating instructions. [See 46 CFR 76.15-10(h)].
Condition: Unknown
Due 28 February 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Door closers are not provided for the doors located on the main deck_x001C_ providing access to the upper deck. Provide and install and prove proper operation of door closers. [See 46 CFR 72.05-25(i)].
Condition: Unknown
Due 28 February 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Halon fire system cylinder storage area is boxed in, not readily accessible. Make cylinder storage area accessible. [See 46 CFR 76.20(e)].
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Provide means of closing engineroom air supply vent closurers.
Condition: Unknown
Due 28 February 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Provide complete servicing of fixed fire system. Servicing to be to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Halon system controls are in the protected space, i.e. pressure switches for vent and engine shutdowns. [See 46 CFR 76.15-10(a)]
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Documentation
Issued 13 February 1998
Resolved
Provide specifications, manufacturers data sheets, UL approvals, specs, etc, for all equipment, carpet, adhesive, under layment, etc. new or replacement installed on the vessel.
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Engineering
Issued 13 February 1998
Resolved
Properly secure all pipe runs against excessive movement and vibration by the use of non-ferrous metal straps. See 46CFR 119.455
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Construction/Loadline
Issued 13 February 1998
Resolved
Muffler room, aft of engineroom, has approximately 12" of water in bilge, dewater void aft of engineroom.
Condition: Unknown
Due 5 March 1998
Resolved 30 March 1998
Electrical
Issued 13 February 1998
Resolved
Properly secure cable runs in accordance with IEEE-45, eliminate all chafing points.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Electrical
Issued 13 February 1998
Resolved
Electrical distribution panel placed in furnace room in back of water heater, not accessible. Remove breaker box from furnace room on the main deck and restore A-60 bulkheads.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Fire Fighting
Issued 13 February 1998
Resolved
CO2 storage location temperature to be within 32-120 degrees F. See Note 10 Plan-Halon 1301 Fire suppression system.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Fire Fighting
Issued 13 February 1998
Resolved
Properly mark fixed gas alarm "When alarm sounds vacate at once Halon being released" IAW 46CFR122.612(b).
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Properly insulate underside of 01 and 02 decks to A 30. "I" Beams supporting the deck are not properly insulated. See AP4 FIRE 2 plan. 17 Feb 98
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Engineering
Issued 13 February 1998
Resolved
Renew as original all damaged fuel lines.
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Engineering
Issued 13 February 1998
Resolved
Properly secure all hoses eliminate all chafing points on hoses etc. see 46CFR 119.410.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Documentation
Issued 13 February 1998
Resolved
Provide approved plans for newly installed vent cut into the main deck aft.Properly radius corners. (2 holes cut in open deck approximately 8X8 inches I"I" beam supports damaged) See NVIC 10-92, CH-1.
Condition: Unknown
Due 5 March 1998
Resolved 31 March 1998
Fire Fighting
Issued 13 February 1998
Resolved
Instructions for operation of the Halon System missing from the cylinder storage area. Provide conplete operating instructions.
Condition: Unknown
Due 28 February 1998
Resolved 30 March 1998
Engineering
Issued 12 December 1997
Resolved
Vessel suffered engineroom fire. Renew/repair as original and prove properoperation of all engineering systems prior to carrying passengers.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Accommodation/Occupational Safety
Issued 12 December 1997
Resolved
Vessel has only one emergency exit from the open upper deck which is an aluminum ladder aft. Provide second means of escape from upper open upper deck.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Construction/Loadline
Issued 17 September 1997
Resolved
PLACE DOCUMENTED NAME ON VESSEL HULL, JAMES J. DOHERTY.
Condition: Unknown
Due 30 September 1997
Resolved 24 October 1997
Lifesaving
Issued 17 September 1997
Resolved
RELABEL LIFE SAVING EQUIPMENT AND FIRE AXE WITH VESSEL'S DOCUMENTED NAME, JAMES J. DOHERTY.
Condition: Unknown
Due 30 September 1997
Resolved 24 October 1997
Lifesaving
Issued 25 June 1997
Resolved
REMAKE PAINTER FOR STARBOARD LIFEFLOAT STACK.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 25 June 1997
Resolved
PROVIDE NEW LINE FOR STARBOARD BRIDGE WING LIFE RING.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 25 June 1997
Resolved
PROPERLY REMOUNT FLOAT LIGHTS FOR LIFE FLOATS ATOP THE PILOTHOUSE.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Electrical
Issued 25 June 1997
Resolved
PROVE PROPER OPERATION OF INSTALLED EMERGENCY LIGHTING.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 25 June 1997
Resolved
PROVIDE PROPER GASKET FOR WATERTIGHT HATCH IN THE FIRST DECK BAR AREA.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 25 June 1997
Resolved
PROVIDE SECURING DEVICES FOR EACH WATERTIGHT HATCH ON THE WEATHER DECK.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Fire Fighting
Issued 25 June 1997
Resolved
PROVE PROPER OPERATION OF THE HAND PUMP.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 25 June 1997
Resolved
PROVIDE NEW LANYARDS FOR ALL FLOAT LIGHTS ON LIFE FLOATS.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 15 May 1996
Resolved
PROPERLY LABEL LIFEJACKET STOWAGE LOCKERS ON THE MAIN DECK.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Construction/Loadline
Issued 15 May 1996
Resolved
MAKE PERMANENT REPAIRS TO FRACTURES NOTED IN THE LAZARETTE COMPARTMENT.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Construction/Loadline
Issued 15 May 1996
Resolved
MAKE PERMANENT REPAIRS TO FRACTURES LOCATED IN THE MUFFLER SPACE.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Fire Fighting
Issued 15 May 1996
Resolved
PROVE PROPER OPERATION OF VENTILATION AND ENGINE SHUTDOWN DEVICES FOR HALONFIREFIGHTING SYSTEM UPON DISCHARGE INTO ENGINE ROOM.
Condition: Unknown
Due 15 May 1996
Resolved 30 May 1996
Lifesaving
Issued 15 May 1996
Resolved
PROPERLY CONNECT LIFE FLOATS TOGETHER WITH PROPER PAINTER LINES WHERE MISSING.
Condition: Unknown
Due 15 May 1996
Resolved 30 May 1996
Lifesaving
Issued 15 May 1996
Resolved
RENEW RETROREFLECTIVE MATERIAL ON LIFE JACKETS IN THE FORWARD MAIN DECK LOCKER, WHERE NEEDED.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996
Resolved
PROPERLY SPACE APART ALL LIFEFLOATS WHERE VERTICALLY STACKED.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996
Resolved
PROVIDE OAR FOR LIFEFLOAT AND STENCIL, WHERE MISSING.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Accommodation/Occupational Safety
Issued 15 May 1996
Resolved
PROPERLY LABEL 3RD DECK PASSENGER CAPACITY IN ACCORDANCE WITH VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996
Resolved
PROVIDE ORANGE STORAGE CONTAINER FOR DISTRESS SIGNALS AND PROPERLY LABEL.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996
Resolved
PLACE 4, 2" WIDE BANDS OF RETROREFLECTIVE TAPE MATERIAL ON EACH RING LIFE BUOY, BOTH SIDES.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Electrical
Issued 15 May 1996
Resolved
PROPERLY SPLICE WIRES TO BOTH VHF-FM RADIOS IN THE PILOT HOUSE.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Navigation
Issued 15 May 1996
Resolved
PROVE PROPER OPERATION OF STERN NAVIGATIONAL LIGHT.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Documentation
Issued 29 February 1996
Resolved
PROVIDE PROOF OF PAYMENT OF THE INSPECTION USER FEE PRIOR TO RECEIVING ANY CREDIT FOR DRYDOCK EXAMINATION.
Condition: Unknown
Due 29 February 1996
Resolved 1 March 1996
Construction/Loadline
Issued 29 February 1996
Resolved
MAKE PERMANENT REPAIRS TO ALL FRACTURES IDENTIFIED IN THE LAZARETTE COMPARTMENT.
Condition: Unknown
Due 29 February 1996
Resolved 1 March 1996
Construction/Loadline
Issued 29 February 1996
Resolved
PROPERLY MARK DRAFT MARKS ON VESSEL'S HULL, FORE AND AFT, PORT AND STARBOARD.
Condition: Unknown
Due 29 February 1996
Resolved 1 March 1996
Construction/Loadline
Issued 29 February 1996
Resolved
MAKE AVAILABLE FOR INSPECTION THE LAZARETTE COMPARTMENT (REMOVE WATER AND ICE).
Condition: Unknown
Due 29 February 1996
Resolved 1 March 1996
Construction/Loadline
Issued 29 February 1996
Resolved
PROPERLY WELD THROUGH HULL FITTING TO THE STARBOARD SIDE A/C COOLING WATER INTAKE.
Condition: Unknown
Due 29 February 1996
Resolved 1 March 1996
Construction/Loadline
Issued 29 February 1996
Resolved
PLACE GASKET ON LAZARETTE HATCH COVER.
Condition: Unknown
Due 29 February 1996
Resolved 1 March 1996
Lifesaving
Issued 11 May 1995
Resolved
RENEW PADDLES FOR LIFE FLOATS.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 11 May 1995
Resolved
PROVIDE SERVICE REPORT INDICATING TESTING OF FIXED HALON SYSTEM TIME DELAY.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 11 May 1995
Resolved
MOUNT GALLEY B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Electrical
Issued 11 May 1995
Resolved
REPAIR EMERGENCY LIGHTS WHERE EXTINGUISHED.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 11 May 1995
Resolved
LABLE PFD STORAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Accommodation/Occupational Safety
Issued 11 May 1995
Resolved
LABEL 02 DECK NUMBER OF PASSENGERS/PERSONS PERMITTED.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 11 May 1995
Resolved
SCHEDULE UNDERWAY EMERGENY DRILLS FOR MASTER AND CREW.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Electrical
Issued 2 May 1994
Resolved
PRIOR TO OPERATING THE #2 SSG BUT NOT LATER THAN 06MAY94, RENEW AND MAKE WATERTIGHT THE NIPPLE CONNECTION IN THE MUFFLER COMPARTMENT ON THE RAW WATER DISCHARGE LINE.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Lifesaving
Issued 2 May 1994
Resolved
STENCIL ALL LIFEFLOATS WITH PERSON CAPACITY AND STENCIL THE NAME OF THE VESSEL ON THE LIFEFLOAT PADDLES NO LATER THAN 06MAY94.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Lifesaving
Issued 2 May 1994
Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTING NO LATER THAN 06MAY94.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Engineering
Issued 2 May 1994
Resolved
PRIOR TO OPERATION, RENEW THE FLAME SCREEN ON THE FUEL TANK VENT LINE.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Accommodation/Occupational Safety
Issued 2 May 1994
Resolved
PRIOR TO OPERATION, INSTALL THE 10 MISSING AIR CONDITIONING PLUGS ON THE PUMPS IN THE ENGINE ROOM.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 2 May 1994
Resolved
PRIOR TO OPERATION, PROVE PROPER OPERATION OF THE PRESSURE RELIEF VALVE ON THE AIR RECIEVER.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 2 May 1994
Resolved
PRIOR TO OPERATION, REMOVE AND PROPERLY STOW ALL FLAMMABLE LIQUIDS FROM THE2ND DECK STORAGE LOCKER.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Fire Fighting
Issued 2 May 1994
Resolved
PRIOR TO OPERATION, PROVIDE FIXED HALON SYSTEM SERVICING REPORT.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 2 May 1994
Resolved
RENEW THE WATERLIGHT ON THE AFT MAIN DECK RING BUOY.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 2 May 1994
Resolved
REHANG ALL LIFE PRESERVER STORAGE PLACARDS NO LATER THAN 06MAY94.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Construction/Loadline
Issued 16 April 1994
Resolved
REPAIR FRACTURED WELDS IN CHAIN LOCKER, #2 COMPARTMENT, #5 COMPARTMENT AND LAZARETTE AS INDICATED.
Condition: Unknown
Due 16 April 1994
Resolved 16 May 1994
Fire Fighting
Issued 30 April 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 30 April 1993
Resolved
AS PER 46 CFR 185.30.3(E) LABEL MAXIMUM PERSONS PERMITTED ON THE TWO UPPER DECKS NO LATER THAN 14 MAY 1993.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 3 September 1992
Resolved
INSTALL SUITABLE ACCESS TO POTABLE WATER TANK FORWARD OF BALLAST TANK LOCATED BETWEEN FRAMES 12 AND 15 TO FACILITATE INSPECTION ON A REGULAR BASIS.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Navigation
Issued 3 September 1992
Resolved
REMOVE UNDERSIZED 12.5 MA CIRCUIT BREAKERS PROTECTING THE VESSEL'S TWO STEERING GEAR MOTORS AND RENEW WITH 25 MA BREAKER SET BETWEEN 193 - 210 AMPERES.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Documentation
Issued 27 March 1992
Resolved
PROVIDE AN APPROVED ELECTRICAL PLAN AND MAKE VESSEL AVAILABLE FOR EXAMINATION.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Documentation
Issued 27 March 1992
Resolved
PROVIDE A VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Documentation
Issued 27 March 1992
Resolved
PRIOR TO CARRYING PASSENGERS POST A VALID STABILITY LETTER FOR VESSEL.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Documentation
Issued 27 March 1992
Resolved
RESUBMIT DECK ARRANGEMENT PLAN AND STRUCTURAL FIRE PROTECTION PLAN TO REFLECT AS BUILT.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992