MAJESTIC PRINCESS

MAJESTIC PRINCESS is a 1989 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1989, most recently in March 2026, along with 130 deficiencies — 1 with no resolution recorded — and 3 casualty investigations between 2019 and 2022.

Records from 1989 to 2026. Most recent: inspection, 31 March 2026.

Built
1989
Last inspected
31 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8920
335337
Flag
UNITED STATES
367179880, 367662840
Maury page id
psix-335337

Inspections, by type

…with no type recorded19
Years with a record 34 calendar years (1989–2026)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)105.8 ft × 25.5 ft × 7.2 ft
Registered tonnagegross 69 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMINUM BOATS, INC. · CROWN POINT, LA, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8920MMSI 367662840 · active · compulsorily equipped · granted 3 January 2025, expires 21 March 2035
WDD6951MMSI 367179880 · active · compulsorily equipped · granted 22 March 2017, expires 12 April 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 7

Inspection history · 89

31 March 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8338708
25 June 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8166886
26 June 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7942436
8 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845502
22 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7693797
16 May 2023 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7694809
17 April 2023 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7670364
17 January 2023 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7619477
21 October 2022 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7581830
21 October 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7582693
30 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7569481
30 September 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7572866
16 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7452129
28 March 2022 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7420100
1 July 2021 Annual Inspection · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7241393
2 May 2021 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7189302
22 April 2021 Hull Examination · In-Service Inspection · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7180966
15 July 2020 MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7005893
16 August 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6785342
13 August 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6781889
11 June 2019 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6709799
10 May 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6681459
29 March 2019 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6652172
21 May 2018 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6419876
16 June 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6178024
17 April 2017 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6126583
31 March 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6114898
12 July 2016 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5937641
21 July 2015 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5191073
19 August 2014 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4959307
25 June 2014 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4899081
5 May 2014 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4850940
20 December 2011 Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4211489
7 July 2011 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4077459
7 July 2009 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3526531
6 May 2009 Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3468752
2 April 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3444701
25 June 2008 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247413
23 April 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3194755
11 April 2007 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2895098
15 March 2005 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2310277
6 December 2004 Re-Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2257073
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977735
11 April 2003 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1772183
20 November 2002 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1720783
19 September 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1679547
30 August 2002 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1668687
26 August 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1666575
19 August 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663752
15 November 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 772231
15 November 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1444658
24 April 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1062377
24 April 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1420498
23 August 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1451595
3 September 1999 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1375894
21 April 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1464854
26 March 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 101687
24 February 1999 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1130755
5 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413461
5 October 1998 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 801847
23 September 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 800188
29 May 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126987
21 October 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 96772
3 September 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 785366
9 April 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1103187
2 October 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 834983
5 September 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1255347
29 April 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082499
29 March 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1077951
15 November 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1184131
6 September 1995 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 871928
26 April 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 102098
7 September 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 863614
5 April 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1389803
19 October 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 842044
8 September 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142069
3 March 1993 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1150379
29 January 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1133824
9 September 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 939261
13 April 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 953132
24 October 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934140
10 September 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 942265
10 September 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1243665
31 October 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1239185
18 September 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 908397
24 August 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1216492
12 October 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1347858
25 September 1989 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324267
1 September 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888402

Deficiency record · 130

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 March 2026 No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. Vessel Dry dock period lapsed on 28FEB2026. Complete credit dry dock prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2025 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Audible alarm is inoperable for all spaces. 46 CFR 119.530(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2025
Resolution: The master of the vessel provided satisfactory video evidence of newly installed alarm bell, MI witnessed operational testing of all spaces w/ high-level float switches.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2025 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Fire pump gage is missing a needle and inaccurate. 46 CFR 181.10-1 (c) "OLD-T"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended and verified proper gauge/psi.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 June 2025 Resolved
Vessels contracted for on or after July 1, 1961 which carry more than 150 passengers shall meet the requirements of subpart 72.01 of Subchapter H (Passenger Vessels) of this chapter. Fire Damper serving the Engine Room located on the aft E/R bulkhead, Port side does not completely secure. 46 CFR 177.10-5 (a) "OLD-T"
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2025
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2025 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Both PORT and STBD Main Engines contain multiple wasted areas on the cooling water/heat exchanger piping, elbows, and attachment points. Additionally, the PORT Main Engine contains crushed/dry-rotted piping serving the heat exchanger. Replace all affected piping sections to satisfaction of Marine Inspector on both main engines. 46 CFR 182.05-1 (a) "OLD-T"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2025
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025 Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. STBD ENG wet exhaust contains 02 injections in engine room, just FWD of the aft engine room bulkhead which are missing proper double-hose clamps. 46 CFR 182.20-20 (a) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2025
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025 Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. STBD ENG wet exhaust in lazarette is missing double hose clamps at both ends of the flexible section. 46 CFR 182.20-20 (a) "OLD T"
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2025
Resolved 24 July 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 June 2025 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Piping serving the sink drain on port side of the vessel in the fuel void contains a heavily corroded seacock which is missing a handle, unable to prevent water ingress in an emergency. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended, verified proper seacock installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2025 Resolved
All unfired pressure vessels shall be Coast Guard approved and installed to the satisfaction of the Officer in Charge, Marine Inspection. Both Port and Stbd air receivers serving the main engines for starting air are rated at 250PSI MAWP. The gauges only range to 200PSI. 46 CFR 182.10-5 (d) "OLD-T"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 24 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2025 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonable safe from electrical shock of personnel. Bar area on main deck contained a power strip with charred power receptacles. 46 CFR 183.01-5 (a) "OLD-T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended, verified removal of power strip.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2025 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended: (2) Overload or circuit protective devices. Distribution/Breaker panel in pilothouse and in fuel tank void are missing blanking devices where there are no breakers installed. 46 CFR 176.25-15 (a) (2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended, verified both panels w/ blanks installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Multiple open plastic trash cans were observed throughout all areas of the vessel. 46 CFR 116.405 (i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended, verified all non-combustible cans removed. All cans renewed w/ metallic enclosures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. No instructions for donning lifejackets were posted onboard the vessel. 46 CFR 122.516 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended, lifejacket donning placards were provided.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 25 June 2025 Resolved
A vessel at anchor shall exhibit where it can best be seen an all-round white light. Vessels anchor light was inoperable COLREGS Rule 30
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: New bulb intalled, verified operation during attendance.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 June 2025 Resolved
Suitable covers, guards or rails shall be installed in way of all exposed and hazardous places such as gears, machinery etc. There is no cover on the starboard generator and starboard main engine which both have moving belts posing a safety risk to the crew and those working in the space. 46 CFR 177.35-15 "OLD-T"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended, both eng and gen had proper guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 June 2025 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Oil pressure gauges/sensor is inoperable on the starboard engine. 46 CFR 182.20-5(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended and verified operation of gauges following new sensor installation.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 June 2025 Resolved
Fuel supply piping shall be of copper, nickel copper, or copper nickel…except that piping of other material such as seamless steel pipe or tubing which provides equivalent safety may be used. Existing valves serving both port and stbd fuel tanks are improperly terminated with non-metallic caps. 46 CFR 182.20-40(a) “Old-T”
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: Attended vessel, verified metallic plugs installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 June 2025 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. PORT generator is inoperable due to a failed starter. 46 CFR 182.10-1 "OLD-T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 21 July 2025
Resolution: New starter installed. Attending MI verified operation of gen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025 Resolved
Propulsion machinery shall be suitable in type and design. Starboard wet exhaust leak found near aft bulkhead. 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025 Resolved
Propulsion machinery shall be suitable in type and design. The starboard shaft seal has leak and packing gland has failed. 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2024 Resolved
Propulsion machinery shall be suitable in type and design for the intended purpose of vessel. Observed outboard port propulsion engine s/w leak. 46 CFR 182.05-1 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2024
Resolution: Video submitted with s/w leak fixed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 June 2024 Resolved
Vessels constructed after July 1, 1961, which carry more than 150 passengers, shall meet the requirement of Subpart 72.05 of Subchapter H. Structural Fire Protection Plan does not indicate the main deck's aft wooden bulkhead; the fire door to galley below the main deck does not adequately self-close and secure. Additionally, the fire door needs to open and close in the full range of motion as designed. 46 CFR 177.10-5 (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Fire door functional. Wooden bulkhead removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2024 Resolved
A vessel of more than 19.8 meters (65 ft) must carry a minimum of three life buoys... Upper deck life buoy not in serviceable condition. 46 CFR 117.70(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2024
Resolution: Lifeboys onboard
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 26 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Install machinery guards on engines & acquire safer gangway for vessel. 46 CFR 115.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2024
Resolution: Safer gangway installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 June 2024 Resolved
The regulations contained in this part are substantially in accord with, and in general are based upon established codes and recognized marine standards and practices. Breaker panel aft and outboard port side of the galley needs to have a breaker directory that is up-to-date IAW good marine standards. Currently, there are three locations labeling breakers on this panel that are not alike. 46 183.01-15(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2024
Resolution: Breaker panel updated.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 June 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in46 CFR 199.175(b)(10)or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel did not carry a first aid kit that was USCG approved. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2024
Resolution: medical kit purchased
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 June 2024 Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible; USCG MI observed electronic navigation system onboard vessel, however, the operator failed to demonstrate the "Declaration of Conformity" wrt the system's commercial and regulatory compliance and the last update to system was in 2019. Additionally, there were no up-to-date charts present. 46 CFR 121.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2024
Resolution: Reciept of charts purchased sent to office
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 January 2024 Resolved
Repair cracks along STBD rub rail.
Action required: 705 - Other - as specified
Due 31 January 2024
Resolved 5 February 2024
Resolution: Vessel repaired cracks along STBD rubrail. Item has been resolved.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2023 Resolved
A door must not be undercut more than 12.7 millimeters (0.5 inches) above the door sill or deck covering. Rugs and carpets must not pass through doorways, but linoleum and similar deck covering may. Vessel's plan is to cut the carpet under the pilot house door, in the "A" class boundary, and secure a threshold plate to the deck. (46 CFR 116.435(c)(5))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 June 2023
Resolution: Attended vessel and verified def rectified.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] hatch located in the forward main deck dinning area was covered by a table and chairs, and was not marked. (46 CFR 122.606)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 June 2023
Resolution: Attended vessel and verified def rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2023 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the cognizant OCMI. The frame or support of each fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck. (46 CFR 118.520)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 June 2023
Resolution: Attended vessel and verified def rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 May 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. The connection for the bilge alarm in the lazarette does not meet the above condition. 46 CFR 120.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 14 June 2023
Resolution: Attended vessel and verified def rectified.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 April 2023 Resolved
There is excessive pitting in the tank space compartment, located forward of engine room. Crop and renew bottom plating in forward three-quarters of tank space where bottom hull plating is 3/8" thick. Must be completed prior to next drydock credit, due 01Jan2024.
Action required: 705 - Other - as specified
Due 1 January 2024
Resolved 7 February 2024
Resolution: Repairs have been completed IAW approved repair plan. Work item has been resolved.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 April 2023 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. A crack was found on the weld of the second from top railing on the aft starboard quarter, main deck. 46 CFR 116.900
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 16 May 2023
Resolution: Provided photo evidence of required repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 April 2023 Resolved
Deck rails (and bulwarks) must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Two cracks were found on welds on the starboard bow bulwark, main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 16 May 2023
Resolution: Provided photo evidence of required repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2022 Resolved
The storage or use of compressed natural gas (CNG) containers within the accommodation area, machinery spaces, bilges, or other enclosed spaces is prohibited. During deficiency check inspection, observed six portable butane stoves and several butane gas canisters presumably used as cooking devices in the vessel’s galley located below the main deck. Butane is considered a compressed natural gas and the portable stoves were not compliant with NFPA 302. The owner/operator verified the butane canisters and stoves would be removed from the vessel prior to passengers. In order to properly document and avoid future occurrences; this CG-835 will be uploaded into the vessel's documents record via MISLE CASE NUMBER:7452129”
Action required: 10 - Deficiency Rectified
Due 16 May 2022
Resolved 16 May 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 April 2022 Resolved
The wire connections for the bilge sensor, for the void before the engine room was not made in a box but twisted and taped in the bilge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 16 March 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 April 2022 Resolved
The bilge alarm in the void before the engine room compartment was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 16 March 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2021 Resolved
Pr-employment testing is required for any individual to serve as crew member unless the individual has passed a chemical test within the previous 6 months OR was subject to random drug testing within the past 185 days. Vessel representative informed attending Coast Guard that 02 members on board where newly hired and were subject to preemployment/random testing. Provide evidence of such testing. Additional, when the individual's exceed this time frame they must be added to the current company's drug and alcohol program. Cite:46 CFR 16.210 (b)
Action required: 705 - Other - as specified
Due 8 July 2021
Resolved 12 August 2021
Resolution: Observed updated DAPI paperwork.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2021 Resolved
Employers must maintain records of chemical tests and must make these records available to Coast Guard officials upon request. Vessel did not have drug and alcohol records on board ready for inspection. Provide a maintained consolidated program on board at all times for inspection. Cite:46 CFR 16.260 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 12 August 2021
Resolution: Observed updated DAPI paperwork.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2021 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test unfired pressure vessels to the extent necessary to determine that their condition is satisfactory. Two PVs in enginre room are overdue for internal visual exam. Cite:46 CFR "OLD" T 176.25-30
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 12 August 2021
Resolution: Conducted successful visual inspection of 02 Pressure vessels on board.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 July 2021 Resolved
At each inspection the marine inspector shall require that all observed unsafe practices and hazardous situations are corrected. Witnessed on most forward starboard side bulkhead a large 4' x 4' section of insulation and hydraulic steering lines exposed to the elements of the galley. Considering its adjacent location to the deep fat fryers and galley stove/oven being a significant ignition source, the existing paneling that was removed to protect the insulation and hydraulic fluid lines shall be replaced to maintain structural fire protection. Cite:46 CFR "OLD" T 176.25-50 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 12 August 2021
Resolution: Observed new paneling covering hydraulic steering lines in galley.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 1 July 2021 Resolved
The master or person in charge of a ship shall ensure that the ship is not operated unless a garbage management plan meeting this section is on the ship and that each person handling garbage follows the plan. (b) Each garbage management plan must be in writing and describe procedures for minimizing, collecting, processing, storing and discharging garbage. As well as designate the person who is in charge of carrying out the plan. No garbage management plan was on board. Cite: 33 CFR 151.57
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 12 August 2021
Resolution: Owner has garbage management plan displayed on the bridge.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2021 Resolved
First aid kits on board must include the following contents that were missing or expired during inspection: (1) Tourniquet, (1) Wire splint, (10) ammonia inhalants Cite:46 CFR 160.041-4 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 12 August 2021
Resolution: Verified items in first aid kit were present.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2020 Resolved
Vessel's fire damper on the port aft side did not operate properly. Ensure port aft fire damper closes satisfactorily. Cite: 46CFR116.610
Action required: 10 - Deficiency Rectified
Due 15 July 2020
Resolved 15 July 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 July 2020 Resolved
Vessel's emergency lightting continuously trips the breaker. Ensure emergency lighting operates as intended. Cite: 46CFR120.432
Action required: 10 - Deficiency Rectified
Due 15 July 2020
Resolved 15 July 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 July 2020 Resolved
Vessel's FCC Safety and Operator Certificates are expired. Renew FCC certificates. Vessel must operate within 1000ft from shore. Cite: 47CFRPart13
Action required: 10 - Deficiency Rectified
Due 15 July 2020
Resolved 15 July 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2019 Resolved
Prior to departure from the pier submit a dive report to the attending MI.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2019 Resolved
Conduct sea trials with the approval of the attending MI.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2019 Resolved
High level bilge alarm in E/R must be placed in junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 11 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 June 2019 Resolved
Thread metallic fitting on port overboard discharge for old AC condensate overboard valve to mirror stbd side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 11 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 June 2019 Resolved
Service both remote damper closures and both remote fuel shutoff valves. Must close 100% and with reasonable amount of effort. Schedule USCG site visit in advance of 30 day due date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 11 July 2019
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2017 Resolved
Provide updated charts
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 4 May 2017
Resolution: Witnessed updated marine charts.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 April 2017 Resolved
Provide 2017 light list and coast pilot publications
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 4 May 2017
Resolution: Witnessed new 2017 Coast Pilot and Light List pubs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 April 2017 Resolved
Remove extension cords and surge protectors throughout vessel
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 4 May 2017
Resolution: Witnessed removal of all extension cords and surge protectors.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 April 2017 Resolved
Provide FCC operator license
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 4 May 2017
Resolution: Witnessed new FCC operator license.
Engineering › Bilge Water Management System › Manifold
Issued 17 April 2017 Resolved
Prove proper operation of fixed bilge piping system in tank room
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Operator installed new valve, tested satisfactory.
Engineering › Bilge Water Management System › Interface Detector
Issued 17 April 2017 Resolved
Prove proper operation of bilge high water alarm in engine room.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Operator installed new bilge sensor, tested satisfactory.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 April 2017 Resolved
Properly label all breakers
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 4 May 2017
Resolution: Witnessed proper labeling of breaker panels.
Navigation › Piloting/Steering › Marine Charts
Issued 13 July 2016 Resolved
Charts are out of date.
Condition: Improper/Lack of Maintenance
Due 20 July 2016
Resolved 28 July 2016
Resolution: UPDATED CHARTS PROVIDED.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 July 2015 Resolved
KB06- Water leaking from port inboard engine exhaust, identified crack in exhaust piping. Repair/Replace exhaust.
Due 1 August 2015
Resolved 1 September 2015
Resolution: Inspected piping repaired aft of the port inboard engine. Started engine and observed no visible leaks from exhaust piping.
Engineering › Bilge Water Management System › Piping
Issued 21 July 2015 Resolved
KB04-Alternate bilge pump suction piping IWO strainer wasted and holed.
Due 1 August 2015
Resolved 1 September 2015
Resolution: Observed installation of two new stainless steel nipples, observed no leaks or corrosion in the vicinity of the strainer.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 21 July 2015 Resolved
KB05-Observed bulging shaft tube hose on port inboard engine, and aged hoses on all four shafts. Submit repair proposal to USCG Sector NY.
Due 21 August 2015
Resolved 1 September 2015
Resolution: Owner states that repair proposal has been submitted to Sector New York detailing a plan to haul out in April, 2016 to effect repairs.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 July 2015 Resolved
KB02- Install corrosion resistant clip on life ring w/ float light.
Due 21 August 2015
Resolved 1 September 2015
Resolution: Observed properly functioning, corrosion resistant clip installed on float light.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2015 Resolved
KB01-Numerous wires dead ended and connected with wire nuts under console. Make proper connections and remove dead end wires.
Due 21 August 2015
Resolved 1 September 2015
Resolution: Inspected wiring under console, improper wire splices removed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 21 July 2015 Resolved
KB03- Prove proper operations of ground detection on engine room switchboard.
Due 21 August 2015
Resolved 1 September 2015
Resolution: Performed operational test of switch board ground detection, with no deflection. Gauge reads 0 amps. Operator states that electrician will submit letter attesting to the proper operation of ground detection.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 June 2014 Resolved
Prepare Drug and Alcohol policy/program and records for audit.
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 7 August 2014
Resolution: Conducted audit of Drug and Alcohol policy/program.
Lifesaving › Lifebuoys › Serviceable
Issued 25 June 2014 Resolved
Renew pilot house ring buoy/wasted grab line, IAW 46 CFR 117.70
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 21 July 2014
Resolution: Provided email documentation with picture showing new life ring.
Lifesaving › Lifebuoys › Serviceable
Issued 25 June 2014 Resolved
Renew retro-reflective tape to aft ring buoy.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 21 July 2014
Resolution: Provided email documentation with picture showing new retro-reflective tape
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 June 2014 Resolved
Provide loading mark to side of the hull IAW stability letter dated 6/4/2012, mark on hull will need to be permanent at next dry dock May 31, 2015.
Action required: 705 - Other - as specified
Due 31 May 2015
Resolved 14 August 2014
Resolution: This item has not been completed but is being closed to accommodate a MISLE update. Unit does not want extended outstanding DEF''s.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 25 June 2014 Resolved
Provide company Policy/Statement.
Action required: 705 - Other - as specified
Due 14 August 2014
Resolved 14 August 2014
Resolution: Company policy signed by all active crew.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 25 June 2014 Resolved
Provide proof of supervisor 1 hour EAP training.
Action required: 705 - Other - as specified
Due 14 August 2014
Resolved 14 August 2014
Resolution: Owner ordered training video from consortium.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 June 2014 Resolved
Provide Substance Abuse Professional name and contact information.
Action required: 705 - Other - as specified
Due 14 August 2014
Resolved 14 August 2014
Resolution: Verified SAP name and contact information.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 7 July 2011 Resolved
Vessel was built with four engines and two generators; one stb engine is broke and in-operable. Vessel must repair this engine then conduct full power trials with a Coast Guard Marine Inspector.
Due 31 October 2011
Resolved 17 April 2012
Resolution: Witnessed proper operations of the stbd engine.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 July 2011 Resolved
Vessel is required to have a fixed fire system in the galley as per the CFR/COI; system has not been checked annually and owner states he wants to take it out of service due to the non-use of the stove. Vessel must not use the galley stove until the FF system is serviced or permanently disable the galley equipment and FF system. Vessel must notify the Chief of Small Passenger Vessels Branch upo
Due 8 August 2011
Resolved 11 August 2011
Resolution: Received letter from [name withheld] and certificates and pictures attesting to satisfactory servicing of fixed fire extinguishing system in the galley.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 July 2011 Resolved
Vessel must update and redo the fire control plan as discussed with CGMI.
Due 30 September 2011
Resolved 20 December 2011
Resolution: Vessel rep submitted fire control plan. Attended vessel to confirm location of fire protection equipment. Drafted plan review letter approving fire control plan.
Documentation › Logs/Records › Drug Test Records
Issued 7 July 2011 Resolved
Vessel must have all crew members in a DAPI or a way for crew sharing to be reported.
Due 21 July 2011
Resolved 11 August 2011
Communications › Radio Communications › EPIRB
Issued 7 July 2009 Resolved
Epirb Hydrostatic release expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2009
Resolved 7 July 2009
Resolution: New Hydrostatic release procured and installed
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 April 2008 Resolved
Existing BA's badly worn, cracked and dry rotted. Renew 8 ba's. Route reduced until resolved.
Action required: 705 - Other - as specified
Resolved 8 January 2009
Resolution: Cleared. Owner chose to reduce route in lieu of satisfying requirement as vessel operate within the harbor.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 23 April 2008 Resolved
Renew torn flame screens on port and stbd gooseneck vent.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Corrected
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 April 2008 Resolved
Prove proper operation of bilge alarms for all (3) compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Corrected
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 April 2008 Resolved
Prove proper operation of aft engine room ventilation dampers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2008 Resolved
Provide proper first aid kit.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 28 April 2008
Resolution: Corrected
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 April 2008 Resolved
Provide compass deviation card.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 28 April 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 April 2008 Resolved
Provide proof of enrollment in drug testing program.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 11 June 2008
Resolution: Corrected
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 April 2008 Resolved
Provide current tide tables.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 28 April 2008
Resolution: Corrected
Navigation › Piloting/Steering › US Coast Pilot
Issued 23 April 2008 Resolved
Provide current coast pilot.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 28 April 2008
Resolution: Corrected
Fire Fighting › Combustible Materials › Insulation
Issued 23 April 2008 Resolved
Replace missing exhaust lagging on port generator exhaust piping.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 11 June 2008
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 April 2008 Resolved
Renew missing insulation/lagging on main engine exhaust pipes in lazzarette.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 11 June 2008
Resolution: Corrected
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 23 April 2008 Resolved
Renew aft engine room vent louvers due to wastage of closure fins.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 8 January 2009
Resolution: Corrected
Engineering › Fuel Oil Service System › Piping
Issued 11 April 2007 Resolved
Repair fuel oil leak to return piping to starboard generator.
Condition: Unknown
Due 18 April 2007
Resolved 18 April 2007
Resolution: Owner repaired oil leak
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 11 April 2007 Resolved
Provide proper lagging to exhaust piping for the starboard generator.
Condition: Unknown
Due 18 April 2007
Resolved 18 April 2007
Resolution: Owner installed lagging
Engineering › Fuel Oil Service System › Hose
Issued 11 April 2007 Resolved
Provide chaffing gear for the port generator fuel oil return line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 18 April 2007
Resolution: Owner installed chafing gear
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 11 April 2007 Resolved
Provide proper clamps for port muffler/exhaust piping.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 18 April 2007
Resolution: Owner installed proper clamps to port muffler
Engineering › Bilge Water Management System › Interface Detector
Issued 11 April 2007 Resolved
Repair lazarette bilge high level alarm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 18 April 2007
Resolution: High level alarm repaired and operational
Communications › Radio Communications › EPIRB
Issued 26 March 2007 Resolved
Epirb expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 11 April 2007
Resolution: Owner renewed Epirb
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 March 2007 Resolved
All extinguishers on board inspection service expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 11 April 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 26 March 2007 Resolved
Repair or replace holes in BA'S
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 11 April 2007
Resolution: Owner repaired B/A''S
Construction/Loadline › Structures › Deck Plating
Issued 15 March 2005 Resolved
Vee-stop and weld cracked plate and weld on swim platform, starboard side.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 16 March 2005
Resolution: Examined satisfactory welding repair.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 15 March 2005 Resolved
Weld pinhole leak on port generator keel cooler.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 16 March 2005
Resolution: Examined satisfactory weld repair. Witnessed satisfactory test of piping under service pressure from the jacketwater inside the piping.
Construction/Loadline › Penetrations › Valve Flange
Issued 15 March 2005 Resolved
Renew wasted bolt on starboard/outboard MDE raw water spool piece.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 16 March 2005
Resolution: Examined new bolt. All sat.
Engineering › Steering Gear System › Rudder
Issued 15 March 2005 Resolved
Renew parted keeper on starboard rudder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 16 March 2005
Resolution: Examined new keeper. All sat.
Lifesaving › Buoyant Apparatus
Issued 30 August 2002 Resolved
Renew retro tape and properly make up pendants on all buoyant apparatuses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 9 September 2002
Resolution: Examined and found satisfactory all pendants.
Navigation › Piloting/Steering
Issued 30 August 2002 Resolved
Provide current copies of Tide Tables, Tidal Current Tables and Navigation Rules publications. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 9 September 2002
Resolution: Examined and found satisfactory all required nav pubs.
Fire Fighting
Issued 23 August 2000 Resolved
Repair leaking flexhose to Jabsco firepump.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Documentation
Issued 23 August 2000 Resolved
The vessel is restricted to not more than 1000 feet from shore until the Radiotelephony Certificate is renewed.
Condition: Unknown
Due 27 September 2000
Resolved 3 October 2000
Documentation
Issued 23 August 2000 Resolved
Provide a copy of the waste management plan.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Documentation
Issued 23 August 2000 Resolved
The vessel is restricted to not more than 1000 feet from shore until the master provides hi FCC operators permit.
Condition: Unknown
Due 27 September 2000
Resolved 3 October 2000
Navigation
Issued 23 August 2000 Resolved
Provide Coast Pilot [name withheld] and current table for operating area.
Condition: Unknown
Due 27 September 2000
Resolved 3 October 2000
Fire Fighting
Issued 23 August 2000 Resolved
Prior to carrying passengers, provide an appropriate fire hose.
Condition: Unknown
Due 27 September 2000
Resolved 3 October 2000
Documentation
Issued 23 August 2000 Resolved
Provide copy of drug testing policy and hotline numbers.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Construction/Loadline
Issued 3 September 1999 Resolved
PROPERLY ADJUST (TIGHTEN) DOGS ON BOTH WATERTIGHT DOORS IN ENGINE ROOM.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Fire Fighting
Issued 3 September 1999 Resolved
PROVIDE SERVICE REPORT FOR GALLEY HOOD FIRE SYSTEM.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Construction/Loadline
Issued 3 September 1999 Resolved
PROPERLY REPAIR BILGE HIGH LEVEL ALARM IN TANK ROOM AND AFTER LAZARETTE.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Lifesaving
Issued 3 September 1999 Resolved
PROPERLY STENCIL B/A WITH VESSEL'S NAME AND CAPACITY. (FORWARDMOST AND UPPERMOST B/A)
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Accommodation/Occupational Safety
Issued 5 January 1999 Resolved
PROVIDE PROOF THAT THE VESSEL MEETS REQUIREMENTS OF 46 CFR 116.500, REGARDING THE TWO MEANS OF ESCAPE FROM THE MAIN DECK CABIN, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Accommodation/Occupational Safety
Issued 5 January 1999 Resolved
PROVIDE PROOF THAT THE VESSEL MEETS REQUIREMENTS OF 46 CFR 116.520(b)(1) asdefined by 46 CFR 114.400(b)(10), REGARDING AREA OF REFUGE, TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Electrical
Issued 23 September 1998 Resolved
BUNDLED CABLE RUNS ADRIFT PORT AND STARBOARD SIDE OF ENGINEROOM. PROPERLY SECURE CABLE RUNS.
Condition: Unknown
Due 1 October 1998
Resolved 5 October 1998
Fire Fighting
Issued 5 September 1996 Resolved
Trouble shoot repair and prove proper closure of lower deck and upper deck stairway fire doors.
Condition: Unknown
Due 6 October 1996
Resolved 2 October 1996
Fire Fighting
Issued 6 September 1995 Resolved
PROVIDE COPY OF CURRENT FIRE SERVICE REPORT FOR FIXED WET CHEMICAL SYSTEM TO GALLEY RANGE PRIOR TO PLACING RANGE IN OPERATION OF 15SEP95.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Construction/Loadline
Issued 6 September 1995 Resolved
PROVIDE MEANS TO MAKE PVC DRAIN LINE IN WAY OF FWD WATERTIGHT BULKHEAD PORTSIDE WATERTIGHT IN ACCORDANCE WITH 46 CFR 171.114. ON OR BEFORE NEXT SCHEDULED DRYDOCK 05APR96.
Condition: Unknown
Due 6 September 1995
Resolved 6 September 1995
Accommodation/Occupational Safety
Issued 8 September 1993 Resolved
INDICATE THE MAXIMUM PASSENGERS ALLOWED ON THE UPPER DECK IN ACCORDANCE WITH THE VESSEL'S STABILITY LETTER AS PER 46 CFR PART 185.30-3(e) NO LATER THAN 08 OCTOBER 93.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Unknown
Issued 29 January 1993 Resolved
RESOLVE DISCREPANCY BETWEEN OBSERVED FREEBOARD ON JANUARY 29, 1993 AND FREEBOARD REQUIRED BY VESSEL'S CURRENT STABILITY LETTER PRIOR TO 5 MARCH 1993.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Lifesaving
Issued 9 September 1992 Resolved
PROVIDE LABEL FOR ENGINEROOM SIDE OF ENGINE ROOM EMERGENCY ESCAPE HATCH_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Fire Fighting
Issued 9 September 1992 Resolved
PRIOR TO OPERATING GALLEY RANGE MAKE REPAIRS TO EXHAUST DUCT AUTOMATIC DAMPER AS PER 46 CFR 72.05-50(H)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Lifesaving
Issued 9 September 1992 Resolved
ALL 12 DISTRESS SIGNALS ARE EXPIRED. REPLACE ALL 12 DISTRESS SIGNALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Accommodation/Occupational Safety
Issued 9 September 1992 Resolved
PROVIDE SUITABLE BRACKET FOR HOT WATER HEATER IN TANK ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Lifesaving
Issued 9 September 1992 Resolved
INSTALL PAINTER LINE BETWEEN ONE B.A. AND THE FIVE REMAINING B.A'S.
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Lifesaving
Issued 9 September 1992 Resolved
PROVIDE LABEL FOR FIRE DAMPERS PULL HANDLES SERVING ENGINEROOM AIR SUPPLY_x001C_ VENT FANS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 September 1992
Resolved 15 September 1992
Engineering
Issued 24 August 1990 Resolved
REMOVE OIL IN MACHINERY SPECE BILGE PRIOR TO CARRIAGE OF PASSENGERS. NOTIFYOFFICER IN CHARGE OF MARINE INSPECTION UPON COMPLETION.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990

Casualty record · 3

16 August 2019Routine · role: Involved in a Marine Casualty · activity 6785342
30 September 2022Routine · role: Involved in a Marine Casualty · activity 7572866
21 October 2022Routine · role: Involved in a Marine Casualty · activity 7582693
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.