Records from 2016 to 2026. Most recent: inspection, 12 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
12 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8295295
20 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8020094
18 December 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046343
7 December 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7836227
15 November 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7824617
8 May 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7683804
4 May 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7643511
28 September 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7559176
6 April 2022
Plan Review (Other than "T") · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7471471
22 March 2022
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380247
11 August 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7283536
4 March 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7138910
27 February 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6887358
12 August 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6781274
31 January 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604873
22 February 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6335199
29 August 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6254724
23 August 2017
Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6248893
9 February 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6070116
3 March 2016
DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5807441
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 February 2025
Resolved
Hull structure cracked weld going between #4 transverse frame port and #2 longitudinal stringer port from keel. Crack propagating into transverse frame.
46 CFR 116.300
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 12 March 2025
Resolution: Operator provided photo and statement of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 February 2025
Resolved
Fuel oil service system. Fuel oil shut off valve does not fully close.
46 CFR 119.435
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 12 March 2025
Resolution: Operator provided video of fuel oil shut off valve rigged and closing fully.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2024
Resolved
Materials and workmanship. The materials and construction of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. Forward in the engine room bilge, fuel valves were found to be weeping diesel fuel and wrapped in oil absorbent pads. Vessel must replace oil absorbent pads daily until fuel valves are repaired/replaced. 46 CFR 119.455 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 8 January 2025
Resolution: Vessel has repaired the weeping area by renewing the threaded pipe connection. Pipe/valve no longer weeps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2024
Resolved
Materials and workmanship. The materials and construction of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. Aft of the fuel tank room bilge, the fuel fitting at the bulkhead was found to be weeping diesel fuel. Vessel must replace oil absorbent pads daily until fuel fitting is repaired/replaced. 46 CFR 119.455 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 8 January 2025
Resolution: Vessel has repaired the weeping area by renewing the threaded pipe connection. Pipe/valve no longer weeps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2024
Resolved
A vessel must be provided with a piping system that meets § 56.50-50 in subchapter F of this chapter. Bilge foot strainer was found to be broken and not attached to bilge suction pipe. 46 CFR 119.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 2 January 2025
Resolution: Bilge foot strainer is now attached.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 December 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI. The scuttle at the forward part of the compartment was not marked with an Emergency Exit sign. 46 CFR 122.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 2 January 2025
Resolution: Scuttle in engine room has been marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 December 2023
Resolved
Observed movement on the port prop key.
Vessel is to have prop removed for inspection. Upon successful inspection prop key is to be installed IAW manufacture SPECs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2024
Resolution: inspected end of dry dock all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023
Resolved
Observed wear on the all cutlass bearings.
Vessel is to provide gauge readings of all cutlass bearings, remove and install approved cutlass bearings that are exceeding 50% wear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2024
Resolution: Cutlass bearing guaged, within spec.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2023
Resolved
Observed STBD shaft lock nut was not backed down onto prop.
Vessel is to lock shaft nut to prop IAW manufacture's SPECs.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2024
Resolved 31 January 2024
Resolution: Shaft nuts inspected end of Dry Dock, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2023
Resolved
Observed exposed dead end wire in #1 void.
Vessel is to place wire in an approved terminal box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 7 December 2023
Resolved
Observed STBD aft bulk ward at gangway entrance has weld failure at the deck.
Vessel is to clean, gouge and weld bulk ward.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2024
Resolution: Repaired weld
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022
Resolved
For subchapter K Vessels with electronic propulsion control, (subsequent) automation testing should be conducted IAW the MSC approved DVTP at commisioning. Vessel upgraded to "Glendenning" controls. Operator provide DVTP to USCG MSC ([email withheld]) for review and approval. USCG Sector LA/LB witnessed satisfactory implementation of DVTPs, vessel may continue operations during plan review.
CG-CVC Policy Ltr 17-07 6.c.ii
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 5 October 2022
Resolution: Operator obtained MSC Approved DVTP's
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
REMOVE ALL DECK PLATES IN ENGINE ROOM TO ALLOW INSPECTION.
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
PROVIDE REPAIR PLAN FOR ALL CROP AND RENEW PATCHES TO USCG FOR REVIEW PRIOR TO CONDUCTING REPAIRS
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
REMOVE STBD SIDE CLEAT FOR INSPECTION.
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
RENEW AFT E/R CENTERLINE BULKHEAD 12” UP
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
CROP AND RENEW MARKED AREAS IWO STBD AND PORT SHAFT SEALS
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
REPLACE ALL BOTTOM PLATE IN VOID 4
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
RENEW MARKED AREAS ON PORT AND STBD SIDE SHELL IN VOID 4
Action required: 705 - Other - as specified
Resolved 28 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2021
Resolved
CROP AND RENEW MARKED AREAS IN PORT SIDE LAZERETTE
Action required: 705 - Other - as specified
Resolved 28 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2020
Resolved
Vessel to renew flexible bilge hose connection in the forepeak, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Vessel properly renew/replaced hose, as indicated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2020
Resolved
Vessel to have 3rd party company properly service & document completed servicing for all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Vessel had company reattend and conduct proper servicing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2020
Resolved
Vessel to remove excess fuel from aft racor bowl on the STBD main propulsion engine, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Vessel removed & cleaned fuel from racor bowl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2020
Resolved
Vessel to properly fix/tighten sea strainer fittings for the STBD main propulsion engine raw water supply, as indicated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Vessel was able to effect repairs and tighten raw water fittings for the STBD main propulsion sea strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2019
Resolved
Each life ring buoy must be in good and serviceable condition. Found tear on port side life ring; replace with new life ring.
Cite from OLD T-L: 46CFR180.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 16 May 2019
Resolution: A new life ring was placed in service
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 January 2019
Resolved
Properly insulate engine room with A-60 structural fire protection in various areas as indicated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 16 May 2019
Resolution: CG approved insulation was installed in all areas of the engine room as identified.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 31 January 2019
Resolved
Provide training log showing proof that crew completed security training IAW ASP.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2019
Resolved 16 May 2019
Resolution: A properly formatted training log has been placed in service.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 31 January 2019
Resolved
Provide updated fire control safety plan submittal.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 16 May 2019
Resolution: Fire control plan has been submitted and placed in service.
Construction/Loadline › Hull › Weld
Issued 25 August 2017
Resolved
Lazarette compartment, upper corner of STBD transom, where deck intersects with hull plating: Deck plating was found to be separated from the hull plating and interior welds were found to be cracked and in poor condition. Repair area to satisfaction of attending Sector LALB CG Marine Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 31 August 2017
Construction/Loadline › Structures › Deck Plating
Issued 25 August 2017
Resolved
Lazzarette compartment, upper corner of Port transom, where deck intersects with hull plating. Deck plating was found with sharp buckles both concave and convex and shows signs of deck plate separation from the hull plating as evidenced by interior weld cracks and gaps. Bent frames and stringers were also noted IVO buckling. Crop and renew buckling deck area (Apx 36 inch long X 14 inch wide) and c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 31 August 2017
Engineering › Pressure Vessel › Weld
Issued 25 August 2017
Resolved
Engine room air receiver: Complete either an internal visual inspection or hydro test. IAW 46CFR 61.10-5 via 176.812
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 29 August 2017
Engineering › Fuel Oil Service System › Vent Pipe
Issued 23 August 2017
Resolved
Renew fuel tank vent screens with corrosion resistant 30X30 wire mesh. IAW 46CFR182.450(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 31 August 2017
Construction/Loadline › Structures › Deck Plating
Issued 9 February 2017
Resolved
Crop and renew to original the hole in void #5 just forward of the lazarette on starboard aft corner.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 23 February 2017
Resolution: Deck plating repaired to the satisfaction of the attending Marine inspector.