MAURY USCG vessel records Sign in
← All vessels

MAJORCA

MAJORCA is a 1990 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1990, most recently in September 2025, along with 194 deficiencies and 3 operational controls.

Records from 1990 to 2025. Most recent: inspection, 24 September 2025.

Built
1990
Last inspected
24 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7334
353745
Flag
UNITED STATES
367391970, 368312090, 368323050
Maury page id
psix-353745

Inspections, by type

…with no type recorded4
Years with a record 31 calendar years (1990–2025)
The 77 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)105.8 ft × 24.0 ft × 8.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)105.8 ft × 24.0 ft × 8.8 ft
ITC tonnagegross 205 / net 61
BuilderSTEINER SHIPYARD, INC. · BAYOU LA BATRE, AL, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it205 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
61 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN9017MMSI 368323050 · active · compulsorily equipped · granted 6 July 2023, expires 6 July 2033
WDN7835MMSI 368312090 · active · compulsorily equipped · granted 4 May 2023, expires 4 May 2033
WDE7334MMSI 367391970 · active · compulsorily equipped · granted 20 November 2018, expires 23 January 2029 · licensed under a name not among this hull’s recorded names (not shown)
WBR8551MMSI not assigned · expired · compulsorily equipped · granted 4 March 1998, cancelled 31 May 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 7

Inspection history · 77

24 September 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8167120
2 April 2025 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8019354
15 February 2025 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8077570
26 September 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7942019
9 March 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875812
12 July 2023 COI Inspection · Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7676344
27 June 2023 Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655182
10 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7398195
21 September 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7317121
26 December 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6846712
10 December 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6846709
18 December 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6597420
3 April 2018 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6383365
19 December 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6314069
9 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6304234
7 November 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6302632
30 November 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6050284
15 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5799644
9 December 2015 COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5772675
27 March 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4816435
24 March 2014 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4778553
13 December 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4196834
7 September 2011 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4138755
9 December 2010 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3901994
1 March 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3680671
17 February 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3417545
2 February 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3397019
3 April 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3488715
5 December 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3109948
3 December 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3107445
12 September 2007 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3054640
4 May 2007 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2924300
29 January 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2842463
6 December 2005 Drydock Extension · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2544724
21 October 2004 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2225240
16 October 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1929206
3 October 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1920356
10 October 2002 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1687492
19 August 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663193
12 July 2002 Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1660099
2 July 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1639881
12 April 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1604400
22 March 2002 Damage Survey
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1597382
22 March 2002 Type not recorded
No type recorded · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1720198
15 November 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1426687
31 October 2001 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415719
21 March 2001 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1061454
4 January 2001 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1421992
29 October 1999 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384280
12 October 1999 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1410184
16 October 1998 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 801965
20 January 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1116209
30 December 1997 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1120802
15 December 1997 Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 779915
21 October 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 96772
1 October 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 781941
30 January 1997 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1102008
10 December 1996 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1091213
21 November 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1180300
15 October 1996 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1154495
29 March 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083501
5 December 1995 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875184
20 October 1995 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 882410
11 October 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1176208
19 February 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1163946
7 December 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 849591
14 October 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 833676
1 April 1993 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1144390
29 December 1992 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1138550
21 October 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1266970
24 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 946192
26 November 1991 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 936996
21 October 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 937781
20 May 1991 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 915139
8 November 1990 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 928616
15 October 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 906389
28 September 1990 Inclining Experiment · Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1225552

Deficiency record · 194

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 September 2025 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Marine inspector observed the line connected to the weak link would get caught and not allow the life float to float free from the vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 September 2025
Resolved 24 September 2025
Resolution: MI observed crew fixed life float rigging during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 September 2025 Resolved
A vessel on a limited coastwise route must carry six hand red flares distress signals and six hand orange smoke distress signals. Marine inspector observed the vessel was missing six hand red flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 September 2025
Resolved 24 September 2025
Resolution: MI observed crew obtained six red hand flares during inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 September 2024 Resolved
A hatch exposed to the weather must be watertight, and must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Lazarette space deck hatch steel retaining cable found broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Chain reconnected to hatch-vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Installed submersible bilge pumps in Laz and bow thruster compartments are on an automatic activation via float switch with no operating indicators on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Indicators added to operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge strainer in #2 plumbing space was found damaged and missing bottom portion of strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Strainer lowered to base of hull to prevent debris from entering bottom.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 September 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Thru-hull penetration for grey water overboard discharge found corroded (galvanic) no longer maintaining hull watertight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Temp repair completed with splash zone. Permanent repair to be completed at DD, special note added to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. Bilge manifold discharge piping missing ball valve handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Handle supplied and installed on valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Each pressure type wire connector and lug must meet UL 486A or other standard specified by the Commandant. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Spliced A/C wire in alcohol storage room made with twist-on wire nuts outside of an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Enclosure provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Switchboard missing nonconducting mat, and deck is aluminum.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Rubber matting installed in entire electrical room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Current electrical 220v installation for anchor windlass is not installed per electrical regulations; system is turned off but not properly tagged out and locked out to prevent accidental use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Breaker turned off and tag applied to breaker to prevent accidental energizing.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Hydraulic oil for bow thruster was found leaking into bilge and accumulation of hydraulic oil was present in bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Hydraulic oil removed from bilge
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical receptacle on navigational bridge found missing faceplate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Faceplate installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Accommodation, recreational facilities?)
Issued 26 September 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Operator provided document.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel is missing all around white light that would be utilized at anchor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: All around light provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of § 84.15. Screens where LED side lights are installed are painted white on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Screens painted matt black
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2024 Resolved
If on a vessel on an oceans or coastwise route, ring buoy/s must be orange in color. All ring buoys were white in color and missing retro-reflective tape (4 strips on each side), vessel on limited-coastwise route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: All 3 ring buoys repalced with buoys that are orange in color
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vent closures need stopping devices to prevent vent covers from mis-aligning and failing to properly cover vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Spacers added in sliding vent covers to assist with alignment.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Sidelights are LED manufactured by Aqua Signal; provide UL 1104 approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Operator provided documents from manufacture
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2024 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative;The EPIRB test shall be logged or otherwise documented, as applicable. No EPRIB test has been conducted or logged since 2023, MI observed test and crew logged test.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2024
Resolution: Tested and logged
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 September 2024 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably....... insulated where necessary to prevent injuries. Lagging on aft generator exhaust was found missing; crew found lagging and reattached in presence of MI.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2024
Resolution: Lagging reapplied
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2023 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) Every power-driven vessel of 20 meters or over in length while navigating; (b) Every vessel of 100 gross tons and upward carrying one or more passengers for hire while navigating. Vessel did not receive their FCC Bridge to Bridge certificate from local FCC Technician. 47 CFR 80.1001
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 7 August 2023
Resolution: Received picture of issued FCC Bridge to Bridge Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2023 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) Every power-driven vessel of 20 meters or over in length while navigating; (b) Every vessel of 100 gross tons and upward carrying one or more passengers for hire while navigating. Vessel did not receive their FCC Radiotelephone certificate from local FCC Technician. 47 CFR 80.1001
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 7 August 2023
Resolution: Received picture of issued FCC Radiotelephone Certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 December 2019 Resolved
Repair hull pitting in compartment #6.
Action required: 705 - Other - as specified
Due 27 December 2019
Resolved 27 December 2019
Resolution: Shipyard made satisfactory repair to pitting in hull by grinding and clad welding to good aluminum.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2018 Resolved
CABLES AND WIRES WERE FOUND IN THE 3RD COMPARTMENT AFT OF THE BOW TO NOT BE INSTALLED WITH METAL SUPPORTS SPACED NOT MORE THAN 24 INCHES APART. PROVIDE METAL SUPPORTS FOR CABLES AND WIRES IN SPACE INDICATED IAW 46 CFR 183.340(b)(4).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2019
Resolved 19 December 2018
Resolution: Received proof from operator that cables and wires in the 3rd compartment aft of the bow were supported with metal supports spaced not more than 24 inches apart. 01 CG-835 cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 December 2018 Resolved
FOUND LIFEFLOAT TO NOT HAVE SERVICEABLE RETROREFLECTIVE TAPE ATTACHED. PROVIDE SERVICEABLE RETROREFLECTIVE TAPE IAW 46CFR164.018.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 December 2018
Resolved 18 December 2018
Resolution: OPERATOR PROVIDED SERVICEABLE RETROREFLECTIVE TAPE FOR LIFE FLOAT. DEFICIENCY CORRECTED ON THE SPOT.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 December 2016 Resolved
Make engine room escape hatch markings readily apparent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 7 November 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 December 2016 Resolved
Make repairs to mast light structure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 7 November 2017
Construction/Loadline › Hull › Stiffener
Issued 14 December 2016 Resolved
Secure port longitudinal stiffener near engine room entrance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 7 November 2017
Engineering › Thrusters › Piping
Issued 15 March 2016 Resolved
Secure hydraulic piping for thruster to existing brackets in #3 void.
Due 16 March 2016
Resolved 15 March 2016
Resolution: Piping attached
Construction/Loadline › Structures › Superstructure
Issued 15 March 2016 Resolved
Renew stbd anchor attachment in way of focsle mount
Due 16 March 2016
Resolved 15 March 2016
Resolution: Mount renewed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 December 2015 Resolved
Complete a satisfactory COI inspection.
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 17 December 2015
Resolution: Completed annual COI exam
Construction/Loadline › Hull › Weld
Issued 26 March 2014 Resolved
Repair as original bottom weld of transverse bulkhead separating lazarette and compartment just forward of lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2014
Resolved 2 April 2014
Resolution: Affected area was ground out and rewelded; all satisfactory.
Fire Fighting › Fire Hoses › Condition
Issued 13 December 2011 Resolved
Replace Aft Fire Hose
Condition: Design Flaw
Due 31 December 2011
Resolved 15 December 2011
Resolution: Replaced aft fire hose and removed old hose from operation.
Engineering › Bilge Water Management System › Not Operational
Issued 9 December 2010 Resolved
Prove proper operation of installed bilge dewatering system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2011
Resolved 14 January 2011
Resolution: Installed bilge dewatering system operated as designed in all 07 compartments.
Fire Fighting › Fire Main › Pressure
Issued 9 December 2010 Resolved
Prove proper operation of installed fire main system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2011
Resolved 7 January 2011
Resolution: Installed fire main system operated properly.
Engineering › Bilge Water Management System › Valve
Issued 9 December 2010 Resolved
Install proper size foot strainer in way of "E-2" Bilge Suction and properly install check valve to function as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Check valve and foot strainer properly installed.
Electrical › Electric Generation Source (service) › Panelboard
Issued 9 December 2010 Resolved
Provide dielectric matting in front of switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Matting provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 December 2010 Resolved
Prove proper operation of compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Compass light operated properly.
Documentation › Certificates/Documents › FCC SSL
Issued 9 December 2010 Resolved
Provide correct call sign.
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Correct call sign provided.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 December 2010 Resolved
Complete drug and alcohol audit.
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 14 February 2011
Resolution: Audit completed
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 9 December 2010 Resolved
Prove pre-employment and enrollment into random drug testing program for all crew members IAW 46 CFR16.230. Crew members not enrolled shall not perform in a safety sensitive function until such time.
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 14 February 2011
Resolution: Drug testing program proven.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 December 2010 Resolved
Provide guards for all lighting fixtures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Guards for all lighting fixtures were properly installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 December 2010 Resolved
Provide approved navigation bulb in way of anchor fixture.
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Approved navigation bulb in way of anchor fixture was installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 December 2010 Resolved
Provide globe in way of anchor light.
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Globe in way of anchor light installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 December 2010 Resolved
Provide approved bracket for portable fire extinguisher in way of forward accomodation space according to manufacturer's instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Approved bracket installed.
Construction/Loadline › Structures › Door
Issued 9 December 2010 Resolved
Renew as original, window in way of aft bulkhead door leading to stern deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Glass window renewed as original.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 December 2010 Resolved
Remove batteries in way of engine room and clean area of all corrosion, re-install.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 7 January 2011
Resolution: Area cleaned of all corrosion and batteries re-installed.
Electrical › Electric Supply System (service) › Cable
Issued 9 December 2010 Resolved
Replace in kind DC electrical cable in engine room in way of welding cable with marine grade boat cable.
Action required: 705 - Other - as specified
Due 4 January 2011
Resolved 14 February 2011
Resolution: DC electrical cable in engine room replaced with marine grade cable.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 9 December 2010 Resolved
Provide proof of pre employment drug testing and documentation kept for entire employment period.
Action required: 705 - Other - as specified
Due 7 February 2011
Resolved 14 February 2011
Resolution: Pre employment drug testing and documentation provided.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 December 2010 Resolved
Provide contact information for Substance Abuse Professional (SAP).
Action required: 705 - Other - as specified
Due 7 February 2011
Resolved 14 February 2011
Resolution: Have phone number.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 9 December 2010 Resolved
Provide proof of MIS report submission for 2010.
Action required: 705 - Other - as specified
Due 7 February 2011
Resolved 14 February 2011
Resolution: Have 2010 MIS report.
Communications › Radio Communications › EPIRB
Issued 1 March 2010 Resolved
Provide float-free device for vessel's EPIRB IAW 46CFR180.64.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 2 March 2010
Resolution: Float-free device installed, verified by attending CG marine inspector.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 1 March 2010 Resolved
Provide valid FCC station license and FCC safety certificate IAW 47CFR10.13 and 47CFR80.401.
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 2 March 2010
Resolution: Valid documents provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 March 2010 Resolved
Ensure navigation lights are installed and operate IAW 46CFR183.420.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 2 March 2010
Resolution: All nav lights operate sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2010 Resolved
Replace and/or repair 02 ring life buoys ensuring proper attachment of required line and waterlight, IAW 46CFR180.70.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 2 March 2010
Resolution: 02 new ring life buoys provided; installed and outfitted as required by regs/COI.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 March 2010 Resolved
Remove mold spores identified in vessel's galley galley and in vessel's heads IAW 46CFR16.818.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 9 March 2010
Resolution: Mold spores removed.
Fire Fighting › Fire Hoses › Condition
Issued 1 March 2010 Resolved
Provide replacement fire hose IAW 46CFR181.320(b).
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 2 March 2010
Resolution: New fire hose provided.
Fire Fighting › Fire Main › Valves
Issued 1 March 2010 Resolved
Repair and/or replace forward fire hose valve IAW 46CFR176.800.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 9 March 2010
Resolution: New valve installed, verified operational.
Construction/Loadline › Hull › Weld
Issued 1 March 2010 Resolved
Repair cracked weld at port steering gear support arm IAW 46CFR176.800.
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 2 March 2010
Resolution: Support arm weld ground out, new weld inspected, found satisfactory.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 February 2009 Resolved
Properly secure wire for stabilizer room bilge high-level alarm IAW 46 CFR 183.10.
Action required: 705 - Other - as specified
Due 2 March 2009
Resolved 17 February 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 February 2009 Resolved
Make forward stabilizer room bulkhead watertight in way of bilge alarm wire.
Action required: 705 - Other - as specified
Due 2 March 2009
Resolved 17 February 2009
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 2 February 2009 Resolved
Conduct test of pressure-relief valve for air reciever IAW 46 CFR 61.10-5
Action required: 705 - Other - as specified
Due 2 March 2009
Resolved 17 February 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 December 2007 Resolved
Provide proof of valid certificate of documentation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2008
Resolved 6 December 2007
Resolution: MISLE status no longer states expired. Case is pending and this 835 is now cleared.
Documentation › Certificates/Documents › FCC SSL
Issued 3 December 2007 Resolved
Provide proof of valid FCC safety certificate IAW 46CFR184.506 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2008
Resolved 4 December 2007
Resolution: Owner/operator faxed copy of valid FCC safety certificate to inspections office.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 3 December 2007 Resolved
Make EPIRB float free IAW 46CFR180.64. Route limited to no more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 3 January 2008
Resolved 6 December 2007
Resolution: Vessel owner/operator replaced entire EPIRB.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 September 2007 Resolved
Various: fractured welds in forepeak, #2 compartment, #3 compartment, & Laz as discussed.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 13 September 2007
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 12 September 2007 Resolved
Clean shaft seal box under all mains.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 3 April 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 September 2007 Resolved
Clean bilge below battery boxes.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 13 September 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 September 2007 Resolved
Secure bilge wiring as high as practicable above bilge.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 3 April 2008
Engineering › Sea-water System (primary cooling) › Valve
Issued 12 September 2007 Resolved
Clean/service thru-hull valves as discussed.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 13 September 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 September 2007 Resolved
Install wire clamps for conductors entering black electrical panel (E/R aft bulkhead)
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 3 April 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 September 2007 Resolved
Install additional lagging on stbd generator exhaust.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 3 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2007 Resolved
Weld pit on the STBD chine in the fuel tank comp.
Action required: 705 - Other - as specified
Due 20 September 2007
Resolved 3 April 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2007 Resolved
Replace center line main raw water coolant hose.
Action required: 705 - Other - as specified
Due 21 September 2007
Resolved 3 April 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 September 2007 Resolved
Complete satisfactory check ride prior to hull credit.
Action required: 705 - Other - as specified
Due 20 September 2007
Resolved 3 April 2008
Engineering › Sea-water System (primary cooling) › Valve
Issued 12 September 2007 Resolved
Exercise centerline main raw water ball valve (STBD side leading to the muffler).
Action required: 705 - Other - as specified
Due 21 September 2007
Resolved 3 April 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 January 2007 Resolved
Provide operating instructions for fixed halon system at local station.
Action required: 705 - Other - as specified
Due 13 February 2007
Resolved 6 February 2007
Resolution: Vsl posted operating instructions.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 January 2007 Resolved
Properly label child lifejackets storage compartment on bow.
Action required: 705 - Other - as specified
Due 13 February 2007
Resolved 6 February 2007
Resolution: Vsl properly labeled lifejackets storage box.
Engineering › Thrusters › Piping
Issued 29 January 2007 Resolved
Provide plans for approval of fin stabilizer hydralic system and bow thruster to OCMI within 30 days.
Action required: 705 - Other - as specified
Due 26 February 2008
Resolved 3 December 2007
Resolution: Plans submited.
Engineering › Thrusters › Motor
Issued 29 January 2007 Resolved
Conduct operational test of fin stabilizer and bow thruster in the presence of attending marine inspector.
Action required: 705 - Other - as specified
Due 26 February 2008
Resolved 3 December 2007
Resolution: Witnessed sat test.
Construction/Loadline › Hull › Hull Plating
Issued 6 December 2005 Resolved
46 CFR 176.600.c.1 Drydock required for hull exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2005
Resolution: Vessel has received a extension for dry-dock exam.
Documentation › Logs/Records › Drug Test Records
Issued 6 December 2005 Resolved
46 CFR Part 16 Provide letter of compliance/enrollment in DAPI consortium prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2005
Resolution: Vessel is in compliance with DAPI program.
Lifesaving › Rescue Boat › Capacity
Issued 6 December 2005 Resolved
46 CFR 180.210 Provide resue boat or platform to retrieve helpless person from the water prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2005
Resolution: Vessel provided resue boat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 December 2005 Resolved
Provide cover to electrical junction box in steering compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel provided cover to electrical junction box.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 December 2005 Resolved
Provide covers to electrical outlets in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel provided electrical outlet covers.
Engineering › Steering Gear System › Pin
Issued 6 December 2005 Resolved
Provide cotter pins to steering gear drift pins.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel installed cotter pins in steering gear drift pins.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 December 2005 Resolved
Remove portable wire from permanent installation on MDEs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel removed portable wires on MDE''s.
Electrical › Electric Generation Source (service) › Panelboard
Issued 6 December 2005 Resolved
Repair voltmeter to #1 SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel repaired voltmeter.
Fire Fighting › Combustible Materials › Insulation
Issued 6 December 2005 Resolved
Re-attach lagging above port engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel reattached loose lagging above port engine.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 6 December 2005 Resolved
Provide black matt behind port nave light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2006
Resolved 12 December 2005
Resolution: Vessel painted navigation light backing on portside.
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 21 October 2004 Resolved
PRIOR TO CARRYING PASSENGERS, PROPERLY INSTALL FIXED FIRE EXTINGUISHING SYSYTEM FOR ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2004
Resolved 23 November 2004
Resolution: E/R FIRE EXTINGUISHING SYSTEM IS PROPERLY INSTALLED.
Lifesaving › Lifefloat › Lifeline
Issued 21 October 2004 Resolved
REPLACE LIFE LINES ON LIFE FLOATS.
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 23 November 2004
Resolution: LIFE LINES REPLACED.
Lifesaving › Lifefloat › Float-free Link
Issued 21 October 2004 Resolved
PROPERLY INSTALL WEAKLINK ON LIFE FLOAT ARRANGEMENT
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 23 November 2004
Resolution: WEAKLINK PROPERLY INSTALLED.
Communications › Audible Communications › Bell
Issued 21 October 2004 Resolved
PROPERLY INSTALL BELL ONBOARD
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 23 November 2004
Resolution: BELL INSTALLED ONBOARD.
Documentation › Certificates/Documents › FCC SSL
Issued 21 October 2004 Resolved
FAX FCC SAFETY CERTIFICATE RENEWAL.
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 23 November 2004
Resolution: FCC SAFETY CERTIFICATION IS ACTIVE.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 21 October 2004 Resolved
FAX FCC MARINE RADIO OPERATOR'S PERMIT
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 23 November 2004
Resolution: RADIO OPERATOR''S PERMIT WAS MADE AVAILABLE FOR INSPECTION.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 21 October 2004 Resolved
PROPERLY POST LIFE JACKET SIGNS ON APPROPRIATE STOWAGE LOCATIONS.
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 23 November 2004
Resolution: SIGNS PROPERLY POSTED.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 16 October 2003 Resolved
Prior to operating perform annual service on fixed Halon system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2003
Resolved 23 October 2003
Lifesaving › Visual Distress Signals (General)
Issued 16 October 2003 Resolved
Provide 6 day and 6 night visual distress signals. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 23 October 2003
Construction/Loadline › Hull
Issued 16 October 2003 Resolved
Make proper weld repairs to cracks on aft rail (3) and cracked weld in #2 void, 4th frame back at 4th long up on stbd side. LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 31 December 2003
Resolution: Examined satisfactory weld repairs.
Stability › Watertight Integrity
Issued 16 October 2003 Resolved
Repair/replace watertight gaskets on all (6) round scuttles.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2003
Resolved 31 December 2003
Resolution: Examined satisfactory gaskets on all scuttles.
Stability › Watertight Integrity
Issued 16 October 2003 Resolved
Install packing on 3 airline runs at fwd engine room bulkhead, and #4 fwd bulkhead, stbd side.
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 31 December 2003
Resolution: Examined bulkhead air line penetrations and found satisfactory.
Engineering › Fuel Oil Service System
Issued 16 October 2003 Resolved
Install handles on Racor fuel filters on port and stbd engines. LEGACY COMPONENT DESC: Valve, Control
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 31 December 2003
Resolution: Examined handles and witnessed satisfactory test of valve closure using new handles.
Pollution Prevention/Response › Prevention Equipment
Issued 16 October 2003 Resolved
Make proper repairs to port sewage drain line. LEGACY COMPONENT DESC: Sewage System Piping
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 31 December 2003
Resolution: Examined satisfactory sewage drain lines. Witnessed satisfactory hydrostatic test of same.
Construction/Loadline › Hull
Issued 16 October 2003 Resolved
Prove watertight integrity of 3 new side shell penetrations from rerouted MDE crankcase breathers (2 stbd / 1 port). LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 3 March 2004
Communications › Alarms/Indicators
Issued 10 October 2002 Resolved
Prior to carrying passengers make repairs to audible engine room bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 29 October 2002
Lifesaving › Embarkation Appliances/Stations
Issued 10 October 2002 Resolved
Vessel is limited to Lake, Bays and Sound route until Lifefloats are properly installed. LEGACY COMPONENT DESC: Designated Location
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 29 October 2002
Navigation › Piloting/Steering
Issued 10 October 2002 Resolved
Provide proper Nav. pubs for operating area (Coast Pilot, Light list, tide/current table). LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 29 October 2002
Accommodation/Occupational Safety › Heating
Issued 10 October 2002 Resolved
Repair Emergency cutout switch (remote) for Fuel Oil furnace.
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 29 October 2002
Stability › Watertight Integrity
Issued 10 October 2002 Resolved
Make proper weld repairs to chip in Compartment #6 watertight scuttle deck ring.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 October 2002
Resolved 29 October 2002
Construction/Loadline › Hull › Weld
Issued 12 July 2002 Resolved
Provide repair proposal for damaged stiffeners and popped welds in steering laz and make proper repairs once approval is granted.
Due 12 August 2002
Resolved 12 August 2002
Resolution: Observed proper welds to corner brackets, new plate insert to msd forward bulkhead, and several pick up welds in the lazarette.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 July 2002 Resolved
Provide service report for fixed fire-fighting extinguisher system.
Due 12 August 2002
Resolved 12 August 2002
Resolution: Witnessed new time release bottle and fittings.
Lifesaving
Issued 4 January 2001 Resolved
Prior to carrying passengers for hire, make rescue platform safe for use, or provide a suitable rescue boat.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 4 January 2001 Resolved
Prior to carrying passengers for hire, make proper repair to approximate 8"x 1/2" hole in sideshell plating in #2 void, last frame bay on port side just above the 3rd longitudinal stringer up from the chine.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Lifesaving
Issued 4 January 2001 Resolved
Prior to carrying passengers for hire, prove float-free ability of all lifefloats found to have lines frozen to the deck.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Engineering
Issued 4 January 2001 Resolved
Prior to carrying passengers for hire, repair leaking diesel fuel return piping in fuel tank space.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Navigation
Issued 4 January 2001 Resolved
Provide a suitably sized bell for sound signalling as frequired by the Inland Navigation Rules, Rule 5.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Fire Fighting
Issued 4 January 2001 Resolved
Prior to carrying passengers for hire, prove proper operation of the aft fire hose station.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 4 January 2001 Resolved
Replace all non-metallic vital system piping sleeve connections with metallic fittings.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Navigation
Issued 4 January 2001 Resolved
Provide 2001 edition of Tidal Current Tables for vessel's area of operations.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 4 January 2001 Resolved
Prior to carrying passengers for hire, make proper repair to broken bilge piping sleeve connection in #6 void and prove proper operation of same to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 19 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 29 October 1999 Resolved
Properly repair the fractures and cracked welds on the port inboard keelsonin the # 6 compartment. Cracks are in the insert plate.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 29 October 1999 Resolved
Remove the lifefloats from under the "A" frame on the bridge overhead.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Construction/Loadline
Issued 29 October 1999 Resolved
Properly repair the cracks in the hull plating in the lazarette space. They are located on the outboard side of the rudderpost at the doubler plate for the outboard gusset.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Navigation
Issued 12 October 1999 Resolved
INSTALL A COAST GUARD APPROVED LIGHT BULB IN ANCHOR LIGHT
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 12 October 1999 Resolved
REPAIR AND REWELD TOP MOST FRAME ON STBD QUARTER.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 12 October 1999 Resolved
REPAIR AND REWELD TRANSOM WEB FRAME, SECOND FRAME FROM STBD SIDE AS MARKED.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 12 October 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARM IN AFTER LAZARETTE AND OPERATIONALLY TEST ALL BILGE HIGH LEVEL ALARMS.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 12 October 1999 Resolved
PROVIDE SERVICE REPORT FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 12 October 1999 Resolved
REPAIR CRACKED WELDS AS MARKED IN #2 VOID SPACE.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Navigation
Issued 16 October 1998 Resolved
Reweld fractured weld on strongback for port steering ram.
Condition: Unknown
Due 23 October 1998
Resolved 26 October 1998
Construction/Loadline
Issued 16 October 1998 Resolved
Make proper repairs, to the satisfaction of the attending marine inspector,to fractured weld on port bottom chord in lazarette in way of aft-most transverse frame.
Condition: Unknown
Due 23 October 1998
Resolved 26 October 1998
Construction/Loadline
Issued 16 October 1998 Resolved
Make proper repair, to the satisfaction of the attending marine inspector, to three(3) fractures on web surface of port bottom chord in way of transom.
Condition: Unknown
Due 23 October 1998
Resolved 26 October 1998
Engineering
Issued 20 January 1998 Resolved
INSTALL FLAME IMPINGEMENT BOWL ON RACOR FUEL FILTER FOR OIL FIRE HEATER.
Condition: Unknown
Due 27 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 20 January 1998 Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THAT THE HALON BOTTLE HAS AN ADEQUATE CHARGE. PROVIDE WRITTEN ATTESTATION FROM SERVICING REPRESENTATIVE TO THIS EFFECT.
Condition: Unknown
Due 27 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 20 January 1998 Resolved
REPLACE SEA VALVE FOR CENTERLINE MAIN ENGINE.
Condition: Unknown
Due 20 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 20 January 1998 Resolved
CROP AND RENEW HULL PLATE IN STEERING GEAR COMPARTMENT 4 INCHES AFT OF STBDRUDDERPOST. THERE IS A 9 INCH CRACK RUNNING TRANSVERSE ACROSS DEEP LONG.
Condition: Unknown
Due 21 January 1998
Resolved 26 January 1998
Engineering
Issued 20 January 1998 Resolved
MAKE CUTLASS BEARINGS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 22 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 30 December 1997 Resolved
COMPARTMENT NR 6 1ST DEEP LONG FROM CENTERLINE BOTH PORT AND STB. WEB FRACTURED AT JUNCTION OF LONG AND FRAMES. ALL CRACKS TO BE DRILLED STOPPED. PERMANENT REPAIR PROPOSAL TO BE SUBMITTED TO MSO BOSTON.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997 Resolved
RUDDER SUPPORT PORT SIDE AFT FRACTURE OF PLATE 4 FEET FROM BOTTOM MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997 Resolved
COMPARTMENT NR. 6 OUTBOARD LONGS BOTH PORT AND STB 4 TOTAL FRACTURED WELDS AT JUNCTION OF LONGS AND 1ST AND 3RD FRAMES.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997 Resolved
COMPARTMENT NR. 7 FRACTURED WELDS AT JUNCTION OF FRAMES AND DEEP LONGS. 2 PORT AND 1 STB.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Navigation
Issued 1 October 1997 Resolved
AT NEXT DRYDOCK APPLY PERMANENT DRAFT MARKINGS TO HULL.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Fire Fighting
Issued 1 October 1997 Resolved
REPLACE BROKEN PRESSURE GAUGE ON DISCHARGE SIDE OF FIRE PUMP.
Condition: Unknown
Due 1 October 1997
Resolved 6 October 1997
Construction/Loadline
Issued 1 October 1997 Resolved
REPLACE FOUR MISSING DOGS ON STARBOARD LOADING DOOR.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997
Construction/Loadline
Issued 15 October 1996 Resolved
PLACE DRAFT MARKS ON THE VESSEL.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Lifesaving
Issued 15 October 1996 Resolved
PROPERLY INSTALL A LIFE JACKET STORAGE PLACARD INDICATING THE NUMBER AND TYPE OF LIFE JACKETS STORED ON THE UPPER DECK.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Accommodation/Occupational Safety
Issued 15 October 1996 Resolved
PROPERLY INSULATE THE MAIN DECK HEATER EXHAUST VENT ELBOW LOCATED ON THE UPPER DECK.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Construction/Loadline
Issued 15 October 1996 Resolved
REPLACE/RENEW AS ORIGINAL THE FIRE/BILGE SEA SUCTION VALVE HANDLE SO AS TO POSITIVELY INDICATE THE POSITION OF THE VALVE.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Construction/Loadline
Issued 15 October 1996 Resolved
GRIND OUT AND REWELD THE FIVE FRACTURED WELDS IN THE LAZARETTE AS DISCUSSEDAND MARKED.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Engineering
Issued 15 October 1996 Resolved
RENEW THE FUEL TANK VENT LINE FLAME SCREEN.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Accommodation/Occupational Safety
Issued 15 October 1996 Resolved
PROPERLY MARK THE MAIN DECK SIDE OF THE ENGINE ROOM EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Lifesaving
Issued 15 October 1996 Resolved
MOVE BOTH GENSET FAN BELT GUARDS SO AS TO INCLUDE PROTECTION FROM ROTATING BELT HUB ASSEMBLY.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Electrical
Issued 15 October 1996 Resolved
REPLACE THE TWO LIGHT GLOBES AND GUARDS IN THE MAIN DECK FORWARD SALON WHERE MISSING.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Construction/Loadline
Issued 5 December 1995 Resolved
RE-ATTACH SECURING CABLE TO COMPARTMENT NUMBER 2 HATCH COVER.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Engineering
Issued 5 December 1995 Resolved
FREE-UP BALL VALVES FOR BOTH PORT AND CENTER MAIN ENGINE COOLING WATER INTAKES.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Construction/Loadline
Issued 5 December 1995 Resolved
RE-ATTACH GASKET MATERIAL TO HATCH COVER FOR THE NO. 2 COMPARTMENT.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Construction/Loadline
Issued 5 December 1995 Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN COMPARTMENT NUMBER 6, PRIOR TO RECEIVING CREDIT FOR DRYDOCK EXAMINATION.
Condition: Unknown
Due 5 December 1995
Resolved 7 December 1995
Construction/Loadline
Issued 5 December 1995 Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN COMPARTMENT NUMBER 2 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO RECEIVING CREDIT FOR DRYDOCK.
Condition: Unknown
Due 5 December 1995
Resolved 7 December 1995
Construction/Loadline
Issued 5 December 1995 Resolved
MAKE PERMANENT REPAIRS TO ALL FRACTURES IN LAZARETTE COMPARTMENT (NO. 7) PRIOR TO RECEIVING CREDIT FOR DRYDOCK, AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1995
Resolved 7 December 1995
Documentation
Issued 5 December 1995 Resolved
PAY INSPECTION USER FEE DUE 01 NOVEMBER 1995 IN THE AMOUNT OF $975.00.
Condition: Unknown
Due 21 December 1995
Resolved 27 December 1995
Lifesaving
Issued 20 October 1995 Resolved
RE-ATTACH LABEL FOR LIFEJACKET STORAGE ON THE MAIN DECK.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Lifesaving
Issued 20 October 1995 Resolved
ATTACH WATERLIGHT TO THE 4TH LIFEFLOAT WHERE MISSING.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Accommodation/Occupational Safety
Issued 20 October 1995 Resolved
PROVE PROPER OPERATION OF THE STARBOARD AFT HEAD.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Electrical
Issued 20 October 1995 Resolved
PROPERLY SPLICE WIRES TO SPEAKER ON BRIDGE, PORT SIDE.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Fire Fighting
Issued 20 October 1995 Resolved
PROPERLY LABEL FIRE AXE WITH VESSEL'S NAME.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Electrical
Issued 20 October 1995 Resolved
PROVE PROPER OPERATION OF THE AFT GENERATOR SET, UNDER LOAD.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Fire Fighting
Issued 20 October 1995 Resolved
CORRECTLY LABEL BOTH HALON SYSTEM TIME DELAY PLACARDS.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Navigation
Issued 20 October 1995 Resolved
PROVE PROPER OPERATION OF PORT SIDE RADAR UNIT, NO LATER THAN 20 NOVEMBER 1995.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 20 October 1995 Resolved
IN COMPARTMENT NUMBER 6 FROM FORWARD, MAKE PERMANANT REPAIRS TO ALL FRACTURES NOTED, NO LATER THAN 20 NOVEMBER 1995.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 20 October 1995 Resolved
IN LAZARETTE COMPARTMENT, MAKE PERMANANT REPAIRS TO ALL FRACTURES NOTED, NOLATER THAN 20 NOVEMBER 1995.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Deck/Cargo
Issued 20 October 1995 Resolved
PROVE PROPER OPERATION OF THE AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Fire Fighting
Issued 20 October 1995 Resolved
SERVICE BII DRY CHEMICAL FIRE EXTINGUISHER ON BRIDGE.
Condition: Unknown
Due 3 November 1995
Resolved 6 November 1995
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELD LOCATED AT STARBOARD LONGITUDINAL SECOND FRAME IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELD LOCATED AT STARBOARD SIDE DECK BEAM SECOND FRAME IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELD LOCATED OUTBOARD AFTERMOST TRANSVERSE FRAME IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELD LOCATED AT STARBOARD TRANSVERSE FRAME SECOND LONGITUDINAL FROM OVERHEAD IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Electrical
Issued 11 October 1994 Resolved
INSTALL MARINE TYPE WIRE CONNECTOR ON SPLICED WIRING TO STERN LIGHT.
Condition: Unknown
Due 18 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELD AT PORT SIDE AFTERMOST TRANSVERSE DECK BEAM SECOND SUPPORT INBOARD IN STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELD LOCATED AT PORT SIDE LONGITUDINAL SECOND FRAME INBOARD AND OUTBOARD SIDES IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
VEE-OUT AND REWELD FRACTURED WELDS AT PORT TRANSVERSE FRAME SECOND LONGITUDINAL FROM OVERHEAD BOTH SIDES OF BEAM IN STEERING COMPARTMENT.
Condition: Unknown
Due 11 November 1994
Resolved 10 November 1994
Accommodation/Occupational Safety
Issued 11 October 1994 Resolved
REPLACE BROKEN WINDOW IN AFT MAIN DECK DOOR.
Condition: Unknown
Due 18 October 1994
Resolved 10 November 1994
Construction/Loadline
Issued 19 February 1994 Resolved
RENEW BOTH FRACTURED WELDS IN THE STEERING SPACE, PORT QUARTER, TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 February 1994
Resolved 20 February 1994
Construction/Loadline
Issued 19 February 1994 Resolved
RENEW BOTH FRACTURED WELD IN COMPARTMENT #2 ON THE PORT SIDE AFT WHERE THE FRAMES INTERSECT THE FLOOR STRINGERS TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 February 1994
Resolved 20 February 1994
Documentation
Issued 14 October 1993 Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM LAND PROVIDE CURRENT FCC RADIOTELEPHONE CERTIFICATE.
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Documentation
Issued 21 October 1992 Resolved
RENEW THE VESSEL'S CERTIFICATE OF DOCUMENTATION PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Engineering
Issued 28 September 1990 Resolved
PROVIDE GUARD FOR MECHANICAL BILGE PUMP BELT, CENTER ENGINE.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Lifesaving
Issued 28 September 1990 Resolved
PLACE ALL FIREFIGHTING AND LIFESAVING EPUIPMENT ON BOARD VESSEL. CORRECT NUMBERS PROVIDED BUT REMOVED FOR PAINTING
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Lifesaving
Issued 28 September 1990 Resolved
POST EMERGENCY INSTRUCTIONS. CORRECTION TO BE MADE TO THE SATISFACTION OF BOSTON [name withheld] PASSENGERS FOR HIRE.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
PROVIDE ALL NECCESARY FCC DOCUMENTS
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
PROVIDE AND POST APPROVED STABILITY LETTER IN AREA TO BE SEEN BY THE PASSENGERS
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990 Resolved
POST CERTIFICATE OF INSPECTION
Condition: Unknown
Due 15 November 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 28 September 1990 Resolved
PROVIDE CORRECT MARKING FOR STOWAGE OF LIFE PRESERVERS
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.