MAURY USCG vessel records
← All vessels

MAJORCA

Built
1990
Last inspected
24 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 September 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE7334
353745
Flag
UNITED STATES
Maury page id
psix-353745

Documentation record

Registered dimensions (L × B × D)105.8 ft × 24.0 ft × 8.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)105.8 ft × 24.0 ft × 8.8 ft
ITC tonnagegross 205 / net 61
BuilderSTEINER SHIPYARD, INC. · BAYOU LA BATRE, AL, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it205 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
61 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

24 September 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8167120
2 April 2025 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8019354
15 February 2025 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8077570
26 September 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7942019
9 March 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875812
12 July 2023 COI Inspection · Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7676344
27 June 2023 Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655182
10 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7398195
21 September 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7317121
26 December 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6846712
10 December 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6846709
18 December 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6597420
3 April 2018 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6383365
19 December 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6314069
9 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6304234
7 November 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6302632
30 November 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6050284
15 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5799644

Deficiency record · 30

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 September 2025 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Marine inspector observed the line connected to the weak link would get caught and not allow the life float to float free from the vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 September 2025
Resolved 24 September 2025
Resolution: MI observed crew fixed life float rigging during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 September 2025 Resolved
A vessel on a limited coastwise route must carry six hand red flares distress signals and six hand orange smoke distress signals. Marine inspector observed the vessel was missing six hand red flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 September 2025
Resolved 24 September 2025
Resolution: MI observed crew obtained six red hand flares during inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 September 2024 Resolved
A hatch exposed to the weather must be watertight, and must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Lazarette space deck hatch steel retaining cable found broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Chain reconnected to hatch-vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Installed submersible bilge pumps in Laz and bow thruster compartments are on an automatic activation via float switch with no operating indicators on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Indicators added to operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge strainer in #2 plumbing space was found damaged and missing bottom portion of strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Strainer lowered to base of hull to prevent debris from entering bottom.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 September 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Thru-hull penetration for grey water overboard discharge found corroded (galvanic) no longer maintaining hull watertight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Temp repair completed with splash zone. Permanent repair to be completed at DD, special note added to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2024 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. Bilge manifold discharge piping missing ball valve handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Handle supplied and installed on valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Each pressure type wire connector and lug must meet UL 486A or other standard specified by the Commandant. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Spliced A/C wire in alcohol storage room made with twist-on wire nuts outside of an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Enclosure provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Switchboard missing nonconducting mat, and deck is aluminum.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Rubber matting installed in entire electrical room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Current electrical 220v installation for anchor windlass is not installed per electrical regulations; system is turned off but not properly tagged out and locked out to prevent accidental use.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Breaker turned off and tag applied to breaker to prevent accidental energizing.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Hydraulic oil for bow thruster was found leaking into bilge and accumulation of hydraulic oil was present in bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Hydraulic oil removed from bilge
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical receptacle on navigational bridge found missing faceplate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 17 October 2024
Resolution: Faceplate installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Accommodation, recreational facilities?)
Issued 26 September 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Operator provided document.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel is missing all around white light that would be utilized at anchor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: All around light provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of § 84.15. Screens where LED side lights are installed are painted white on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Screens painted matt black
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2024 Resolved
If on a vessel on an oceans or coastwise route, ring buoy/s must be orange in color. All ring buoys were white in color and missing retro-reflective tape (4 strips on each side), vessel on limited-coastwise route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: All 3 ring buoys repalced with buoys that are orange in color
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vent closures need stopping devices to prevent vent covers from mis-aligning and failing to properly cover vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Spacers added in sliding vent covers to assist with alignment.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Sidelights are LED manufactured by Aqua Signal; provide UL 1104 approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 17 October 2024
Resolution: Operator provided documents from manufacture
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2024 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative;The EPIRB test shall be logged or otherwise documented, as applicable. No EPRIB test has been conducted or logged since 2023, MI observed test and crew logged test.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2024
Resolution: Tested and logged
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 September 2024 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably....... insulated where necessary to prevent injuries. Lagging on aft generator exhaust was found missing; crew found lagging and reattached in presence of MI.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2024
Resolution: Lagging reapplied
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2023 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) Every power-driven vessel of 20 meters or over in length while navigating; (b) Every vessel of 100 gross tons and upward carrying one or more passengers for hire while navigating. Vessel did not receive their FCC Bridge to Bridge certificate from local FCC Technician. 47 CFR 80.1001
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 7 August 2023
Resolution: Received picture of issued FCC Bridge to Bridge Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 July 2023 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) Every power-driven vessel of 20 meters or over in length while navigating; (b) Every vessel of 100 gross tons and upward carrying one or more passengers for hire while navigating. Vessel did not receive their FCC Radiotelephone certificate from local FCC Technician. 47 CFR 80.1001
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 7 August 2023
Resolution: Received picture of issued FCC Radiotelephone Certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 December 2019 Resolved
Repair hull pitting in compartment #6.
Action required: 705 - Other - as specified
Due 27 December 2019
Resolved 27 December 2019
Resolution: Shipyard made satisfactory repair to pitting in hull by grinding and clad welding to good aluminum.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2018 Resolved
CABLES AND WIRES WERE FOUND IN THE 3RD COMPARTMENT AFT OF THE BOW TO NOT BE INSTALLED WITH METAL SUPPORTS SPACED NOT MORE THAN 24 INCHES APART. PROVIDE METAL SUPPORTS FOR CABLES AND WIRES IN SPACE INDICATED IAW 46 CFR 183.340(b)(4).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2019
Resolved 19 December 2018
Resolution: Received proof from operator that cables and wires in the 3rd compartment aft of the bow were supported with metal supports spaced not more than 24 inches apart. 01 CG-835 cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 December 2018 Resolved
FOUND LIFEFLOAT TO NOT HAVE SERVICEABLE RETROREFLECTIVE TAPE ATTACHED. PROVIDE SERVICEABLE RETROREFLECTIVE TAPE IAW 46CFR164.018.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 December 2018
Resolved 18 December 2018
Resolution: OPERATOR PROVIDED SERVICEABLE RETROREFLECTIVE TAPE FOR LIFE FLOAT. DEFICIENCY CORRECTED ON THE SPOT.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 December 2016 Resolved
Make engine room escape hatch markings readily apparent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 7 November 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 December 2016 Resolved
Make repairs to mast light structure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 7 November 2017
Construction/Loadline › Hull › Stiffener
Issued 14 December 2016 Resolved
Secure port longitudinal stiffener near engine room entrance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2017
Resolved 7 November 2017
Engineering › Thrusters › Piping
Issued 15 March 2016 Resolved
Secure hydraulic piping for thruster to existing brackets in #3 void.
Due 16 March 2016
Resolved 15 March 2016
Resolution: Piping attached
Construction/Loadline › Structures › Superstructure
Issued 15 March 2016 Resolved
Renew stbd anchor attachment in way of focsle mount
Due 16 March 2016
Resolved 15 March 2016
Resolution: Mount renewed