Records from 2007 to 2026. Most recent: inspection, 20 June 2026.
Inspection history · 35
20 June 2026
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8427246
7 October 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8230426
21 August 2025
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8213353
26 June 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8196879
1 May 2025
Examination of Repairs · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8135908
2 October 2024
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8000491
14 May 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7914682
11 October 2023
Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7803450
22 July 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7790774
23 May 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7695139
23 May 2023
Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7695443
22 May 2023
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7686172
15 November 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7593913
2 June 2022
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7459783
14 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7255164
5 May 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7189773
3 November 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7090775
14 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7002671
24 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840926
18 April 2019
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6662635
4 December 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6591973
9 October 2018
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6580347
6 October 2018
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6556503
6 October 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6567321
25 August 2018
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6523066
25 August 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6523418
18 June 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6447931
11 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6410300
5 April 2018
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6386327
12 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6144522
3 November 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036815
13 August 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5973302
13 August 2016
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5976593
4 May 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5868870
29 March 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5842554
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 October 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:A means to
reset devices used to automatically shut down
ventilation systems and engines as required by paragraph
(a)(3) of this section. Controls failed to override the
shutoff and restart the engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2025
Resolution: Operator demonstrated satisfactory operation of the system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 October 2025
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. STBD steering linkage bolt was loose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2025
Resolution: Linkage tightened, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Port shut off valve spun fully around.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2025
Resolution: Valve tested, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 October 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel did not have required contents of first aid kit. Vessel's first aid kit was missing multiple required items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2025
Resolution: Required items added, all sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 October 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The lazarette bilge high level alarm did not provide visual alarm at operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2025
Resolution: Visual alarm repaired, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Starboard fuel tank vent flame screen was damaged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2025
Resolution: Flame screen replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2025
Resolved
Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. Fire hydrant closure valve on deck near operating station ladder was leaking while fire main was energized.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 October 2025
Resolution: Operator provided video evidence that new fire hose had been installed and leak had been corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 May 2025
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The port passenger rail stanchion 4th forward from the stern was cracked at the base. Repair to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 4 June 2025
Resolution: Operator rewelded railing
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 May 2025
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The passenger embarkation gate was missing a securing nut on the lower hinge bolt and the eye hole for the gate lock pin was excessively worn. Repair to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 4 June 2025
Resolution: Operator fixed passenger gate
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2024
Resolved
Except as otherwise allowed by this subpart, a vessel
must comply with the structural design requirements of
one of the standards listed below for the hull material
of the vessel. Aluminum hull vessels: ABS High Speed
Craft. Marine inspectors found pitting in the second
void space along the port and starboard sides of the
hull adjacent to the keelson. Pit gauge measurements
revealed individual pits and pit clusters with measured
wastage up to 3/16". Submit repair plan proposal to OCMI
for approval prior to conducting repairs. 46 CFR 177.300(d)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2025
Resolution: Repair plan submitted and approved by [name withheld] satisfactorily completed and welds of the insert tested with satisfactory results under observation of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2024
Resolved
Shutoff valves, installed so as to close against the
fuel flow, must be fitted in the fuel supply lines, one
at the tank connection and one at the engine end of the
fuel line to stop fuel flow when servicing accessories.
The shutoff valve at the tank must be manually operable
from outside the compartment in which the valve is
located. If the handle to the shutoff valve at the tank
is located inside the machinery space, it must be
located so that the operator does not have to reach more
than 12 inches into the machinery space. The cable
connected to the port fuel shutoff valve detached during
valve closure testing. Crew was able to fix the cable
linkage and successfully test the fuel shutoff valve
prior to the marine inspector departing the vessel. 46 CFR 182.455(b)(4)
Action required: 10 - Deficiency Rectified
Due 2 October 2024
Resolved 2 October 2024
Resolution: Deficiency rectified while on board.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 October 2024
Resolved
The discharge ends of fuel tank vent pipes must be
fitted with removable flame screens or flame arresters.
The flame screens must consist of a single screen of
corrosion resistant wire of at least 30 x 30 mesh. The
port side fuel vent was missing the removable flame
screen. Install flame screen to the satisfaction of the
attending marine inspector. 46 CFR 182.450(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 17 October 2024
Resolution: Flame screen was installed on the port side fuel tank vent. Attended vessel to verify satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2024
Resolved
Portable fire extinguishers must be located so that they
are clearly visible and readily accessible from the
space being protected. The installation and location must be to the satisfaction of the OCMI. The portable fire extinguisher located at the operating station was not bracketed in place to as to be secured in its stored position. Properly secure portable fire extinguisher to the satisfaction of the attending marine inspector. 46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 17 October 2024
Resolution: Portable fire extinguishing located at operating station was properly secured via mounting bracket. Attended vessel to verify satisfactory arrangement.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2024
Resolved
A vessel must comply with the structural design
requirements of one of the standards listed below for
the hull material of the vessel. Aluminum hull vessels:
ABS High Speed Craft. The third void space port hull
sideshell had three holes where bolts had previously
secured a metal plate to the hull. The holes are located
above the waterline but below the weather deck. Holes to
be repaired to restore watertight integrity to hull
sideshell to the satisfaction of the marine inspector. 46 CFR 177.300(d)(2)
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 17 October 2024
Resolution: Vessel had the same type of metal cover with bolts reinstalled to restore watertight integrity. Attended vessel to inspect replacement of cover.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 October 2024
Resolved
Except for a storage battery used in a rescue boat, each
battery without an expiration date indicated on it or
for which the owner or managing operator does not have a
record of the expiration date, used in an item of
lifesaving equipment, must be replaced during the annual
inspection. The water light batteries for the life
floats and ring buoys did not have expiration dates
marked on the batteries. Renew water light batteries to
the satisfaction of the attending marine inspector. 46 CFR 185.726(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 17 October 2024
Resolution: Battery replaced in ring life buoy water light. Inspected expiration date marking while on board.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 October 2024
Resolved
Each vessel must be equipped with at least two operable
portable battery lights. Vessel was missing one portable
battery light. Prior to MI departing crew provided two
functioning portable lights. 46 CFR 183.430
Action required: 10 - Deficiency Rectified
Due 2 October 2024
Resolved 2 October 2024
Resolution: Corrected during the inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 October 2024
Resolved
Every vessel subject to Part III of Title III of the
Communications Act must have a detailed inspection of
the radio installation by an FCC-licensed technician in
accordance with 47 CFR 80.59 once every five years and
be issued a Communications Act Safety Radiotelephony
Certificate. The Safety Radiotelephony Certificate was
expired. Vessel is restricted to operating no further
than 1,000 feet from shore while in service until issued
a Safety Radiotelephony Certificate. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 2 June 2025
Resolution: Operator provided evidence in the form of emailed attachment of the radio safety telephony certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 October 2024
Resolved
Rail courses or the equivalent must be installed between
a top rail required by paragraph (a) of this section,
and the deck so that no open space exists that is more
than 12 inches high except on passenger decks of a
vessel on an excursion trip the following must be
installed... bars, slats, rail courses, or an equivalent
spaced at intervals of not more than 4 inches. Vessel's
aft deck section has an opening between the deck and the
stern bench exceeding 12 inches in height without a rail
course of not more than 4 inch intervals. Submit repair
proposal to OCMI for approval prior to repair work. 46 CFR 177.900(g)(1)(iii)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 4 June 2025
Resolution: Operator installed appropriate courses.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 October 2023
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light fixture in engine room was missing guard and light bulb. 46 CFR 183.410(a) 701c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 28 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 October 2023
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Submersible pump in lazarette does not engage when automatic switch is activated.46 CFR 182.100 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2023
Resolved 19 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 May 2023
Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from machinery failure. Vessel experienced a loss of maneuverability while transiting inbound to dock. Vessel to identify cause of machinery failure, affect repairs and conduct satisfactory sea trial in presence of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2023
Resolved 27 May 2023
Resolution: Vessel diagnosed issue to be an unknown redundant power switch for the maneuvering buckets. Vessel removed extra switch and satisfactory sea trials were conducted in presence of Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 May 2023
Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from machinery failure. Vessel experienced an allision while docking due to unknown issue with jet drive propulsion system. Vessel to identify cause of machinery failure, affect repairs and conduct satisfactory sea trial in presence of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2023
Resolved 24 May 2023
Resolution: Verified proper operation of maneuvering system and conducted satisfactory sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2023
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The fire extinguisher located at the operation station was not stored in permanent bracket or in a manner that would prevent damage to extinguisher while underway.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 June 2023
Resolved 17 August 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 May 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length,
a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting such as a lazarette.
Vessel's engine room high water alarm did not have a working visual indicator at operating station and vessel's lazarette audible and visual high water alarm were completely inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 24 May 2023
Resolution: Verified proper operation, visual and audible, of both high water alarms onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Navigational charts that were on board the vessel were from 2014 and 2017 respectively and were not corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 6 June 2023
Resolution: Proper updated charts for the operating area have been purchased and placed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personal injury. Vessel's port main diesel engine had a significant oil leak on aft end of engine underneath turbo charger posing a possible fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 24 May 2023
Resolution: Verified leak was from faulty oil sensor seal. Replaced seal and cleaned up fire hazard.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 2 June 2022
Resolved
Penetrations in watertight bulkheads must be made to be watertight. The watertight bulkhead between the tank and engine room has penetration from an old electrical cable. Make the penetration watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 2 June 2022
Resolution: Rcvd photos showing the penetrations were made watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2022
Resolved
Connections must be made to battery terminals with permanent type connectors. The connectors are using temporary wingnuts. Replace the wingnuts with permanent connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 2 June 2022
Resolution: Rcvd photos of the battery terminals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2021
Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. A stop-check valve located at a control point or manifold will meet the requirements for both a stop valve and a check valve. The bilge suction lines did not have a check valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 18 August 2021
Resolution: Inspected installed check valves on all bilge suction lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2021
Resolved
A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less than 25 millimeters (1 inch) nominal pipe size. A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. The bilge strainer on the Lazarette and the two spaces forward did not meet the strainer size.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 18 August 2021
Resolution: Inspected installed strainers on all bilge suctions are of appropriate size.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 July 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Expose wires at the operation station, and the electrical switch panel was empty and not blanked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 10 August 2021
Resolution: Wires were covered and the switch panel were blanked properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump, provided that the pump is permanently mounted. Engine room electric submersible pump was not permanently mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 10 August 2021
Resolution: The electric submersible pump was permanently mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Engine room electric submersible pump light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 10 August 2021
Resolution: The light is working properly on manual and automatic.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 July 2021
Resolved
A power driven vessel underway shall exhibit sidelights.
The vessel sidelight on the STBD was not exhibiting an unbroken light arc of the horizon of 112.5 degree. Demonstrate proper operation of the navigation light. Vessel restricted to day operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 10 August 2021
Resolution: The navigation light is operating correctly as per regulation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2021
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge. The pressure gauge on the pump did not read 60 psi. After changing the gauge the PSI was satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 July 2021
Resolution: Tested fire pump, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. The markings for the fuel shutoff were not present.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 August 2021
Resolution: Inspected markings for fuel shut off, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2021
Resolved
Ring life buoy must be marked with Type II
retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring Buoy was missing the retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 18 August 2021
Resolution: Inspected ring buoy, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 July 2021
Resolved
Repairs or alterations to the hull, machinery, or
equipment that affect the safety of the vessel must not
be made without the approval of the recognized OCMI...
The shore side installation does not match the approved
drawing approved by MSC. Operator or owner must submit drawings for approval, until approved the circuit must not be utilized.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 15 October 2021
Resolution: locally approved line drawing, verified installation.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 November 2020
Resolved
During a drydock examination, all accessible parts of the vessel's underwater body will be examined. The turnbuckles and bolts in vicinity of port and starboard aft jet drives are corroded.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 5 May 2021
Resolution: Operator submitted photos of turnbuckles and bolts. They were cleaned and are in good condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 November 2020
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other device of substantial strength to prevent its loss. #4 void watertight hatch cover is inadequately attached to the vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 5 May 2021
Resolution: Operator submitted photos of captive chain installed correctly to hatch cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2020
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Vessel's steering rod is deformed and not of acceptable strength for normal operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2020
Resolved 16 July 2020
Resolution: New steering rod installed as per original design. Tested underway with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 July 2020
Resolved
On a vessel of not more than 65 feet carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute and not less than 60 psi. Vessel's fire pump reached a maximum output of 30 psi.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2020
Resolved 16 July 2020
Resolution: New pressure gauge installed. Tested fire pump. Reached 60 psi output at the pump.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2020
Resolved
On a vessel of at least 26 feet, a visual and audible indicator must be provided at the operating station to indicate a high water level. Indicator light for high water level alarm was not operable. Vessel is given 7 days to rectify from the date of Inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2020
Resolved 16 July 2020
Resolution: Retested bilge high level switch. Indicator light activated properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2019
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment. Starboard fuel shutoff valve inoperable.
(Prior to carrying passengers)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
Resolution: New valve was installed. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2019
Resolved
At each subsequent inspection the portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. The portable fire extinguisher located at the operating station and the portable fire extinguisher located at the bottom of the stairs are low.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2019
Resolved 18 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2019
Resolved
03:Each item of lifesaving equipment determined by the Marine Inspector to not be in serviceable condition must be repaired or replaced. The life ring grab line is deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 2 May 2019
Resolution: New life ring was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2018
Resolved
Propulsion machinery must be suitable in type design for propulsion requirements and capable of operating at constant machine load under such requirements. Vessel was experiencing intermittent engine shut down. Vessel required to conduct sea trials & prove proper engine operations under normal conditions.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2018
Resolution: Vessel conductED sea trials & prove proper engine operations under normal conditions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 August 2018
Resolved
Remove and replace cracked nozzle on the port engine. Conduct sea trials to prove proper operation after repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2018
Resolved 26 August 2018
Resolution: Removed and replaced cracked nozzle on the port engine. Conducted sea trials to prove proper operation of both engines.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 11 May 2018
Resolved
Multiple battery terminals are broke. Replace terminals.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2018
Resolution: All battery terminals were found to be intact and securely fastened to the battery posts.
Fire Fighting › Fire Pumps › Pressure
Issued 11 May 2018
Resolved
Pressure guage missing on firepump. Install gauge.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 15 May 2018
Resolution: Fire pump pressure gauge was installed and operational.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 May 2018
Resolved
Pre-Engineered system means to reset device is inoperable. Prove proper operation of reset device.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2018
Resolution: Pre-engineered fire system was fully functional in normal and override modes.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 May 2018
Resolved
Conduct underway drills.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2018
Resolution: Conducted satisfactory underway man overboard and fire drills.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2017
Resolved
Port fwd handrails are cracked. Port aft handrails are cracked. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 31 May 2017
Resolution: Handrails repaired forward and replaced aft.
Construction/Loadline › Hull › Hull Plating
Issued 13 August 2016
Resolved
Damage caused by collision to both port and starboard aft sections of the vessel. Repair and make watertight to the satisfaction of attending Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2016
Resolution: Voids were welded and made watertight. SAT.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 May 2016
Resolved
Stantion #6 and #7 on port side are cracked. Grind and weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 24 May 2016
Resolution: Welds on stancions re-welded.
Construction/Loadline › Hull › Weld
Issued 4 May 2016
Resolved
STBD side seat row #3, #3, #4, and rows #2, and #3 on port side have cracked welds. Grind and weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 24 May 2016
Resolution: Broken welds on seats re-welded.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 May 2016
Resolved
Port and STBD side hand rail courses missing. Install courses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 24 May 2016
Resolution: Rail courses installed usiing cable.