Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-57755
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2022Resolved
Installed electrical power sources must be capable of carrying the electrical load of the towing vessel under normal operating conditions. Vessel's Generator went offline due to a faulty voltage regulator while operating. Vessel notified CG. ABS to clear deficiency (TSMS).
Action required: 705 - Other - as specified
Due 23 January 2022
Resolved 26 January 2022
Resolution: Received class report attesting to satisfactory testing of 01 Generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2020Resolved
steering cable jumps from track of pulley. Repair so the cable cannot jump out of the track.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2020
Resolved 16 August 2021
Resolution: TPO responsibility