Records from 2002 to 2016. Most recent: inspection, 14 September 2016.
Inspection history · 40
14 September 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6000413
18 February 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5817436
26 January 2016
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5803348
10 November 2015
Ballast Water Examination · ISPS III Exam · NPV Safety Exam · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5760768
10 November 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5761172
9 November 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5760612
7 August 2015
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5205614
22 December 2011
COE-Administrative
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4212646
24 September 2011
COE-Dockside
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4153232
18 July 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4086125
27 November 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3898093
15 March 2010
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3696300
5 March 2010
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3690693
3 March 2010
COE-Dockside
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3689264
26 December 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3654170
5 December 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3374716
1 November 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3355529
28 November 2007
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3105684
21 September 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3062635
21 September 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3062636
21 September 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3062638
5 September 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3049903
25 June 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2973943
15 June 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2962584
14 June 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2961066
20 September 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2782806
20 September 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2783565
29 August 2006
ISPS II Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2758040
19 October 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2513941
7 October 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2510000
14 October 2004
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2220895
6 October 2004
Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2214646
30 July 2004
ISPS II Exam · In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2150845
30 July 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2153054
29 December 2003
Type not recorded
No type recorded · USCGC CAMPBELL (WMEC 909) · Activity 1972014
3 October 2003
Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1920676
9 July 2003
Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1840448
23 August 2002
Deficiency Check
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1666362
23 August 2002
Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1666571
5 August 2002
Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1651288
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 November 2015
Resolved
1745- Oil filtering equipment shall be provided with alarm arrangements to ensure that any dishcharge of oily mixtures is automatically stopped when the effluent exceed 15 ppm. In considering the design of such equipment and approvals, the administration shall have regard to the specification recommended by the organization. See full deficiency in narrative. MARPOL 73-78 Annex I/14.7 MEPC. 107 (4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2015
Resolution: Reviewed Class report, SAT.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 November 2015
Resolved
0981- The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. In the engine room, PSCO observed multiple soft patches on the steam condensing lines and a broken step on the stairway leading to the engine control room. 74 SOLAS (2014)I/11 16ac
Action required: 705 - Other - as specified
Due 24 November 2015
Resolved 21 November 2015
Resolution: Reviewed class report, SAT.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 November 2015
Resolved
0750-In addition to complying with specific provisions for fire integrity of bulkheadsand decks mentioned elsewhere in this part,the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. Bulkhead fire protection insulation was damaged in port aft side of CO2 room and bottom section of the bulkhead in the battery room behind the bridge.74 SOLAS(2001)II-2/44.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 November 2015
Resolution: Reviewed class report, SAT.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 November 2015
Resolved
0230- Satisfactory means (in the form of guard rails, life lines, gangways, or under deck passages, etc) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and all other parts used in the necessary work of the ship. Side railing is damaged port side, outboard of #4 cargo hold. See full deficiency in narrative. ICLL 66/25.4 50ac
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 21 November 2015
Resolution: Reviewed class report, SAT.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 November 2015
Resolved
0950- Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed dead end wiring on #1 hopper located on the aft section in the overhead. 74 SOLAS (2004)II-1/40.1.3 50ac
Action required: 705 - Other - as specified
Due 10 December 2015
Resolved 21 November 2015
Resolution: Reviewed class report, SAT.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 10 November 2015
Resolved
1540- A gyro compass heading repeater, or other means to supply heading information visually at the emergency steering postion if provided. The compass at the emergency steering station was not accurate and showed a heading of 171' while multiple compass stations on the bridge showed 178'. 74 SOLAS (2014)V/14.2.5.2 10c
Action required: 705 - Other - as specified
Resolved 10 November 2015
Lifesaving › Lifeboat Equipment › Thermal Protective Aid
Issued 5 December 2008
Resolved
74 SOLAS (2004 Cons.) CH. III, Reg. 32 (3.2); LSA Code CH. IV (4.1.S.1.24): 01 thermal protective aids are missing in each port and starboard lifeboats. Provide proof of purchase of 02 thermal protective aids to the USCG prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2008
Resolution: Received receipt of purchase and delivery of 02 thermal protective aids.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 5 December 2008
Resolved
74 SOLAS (2004 Cons.) CH. III, Reg. 31.1.1.1; LSA Code CH. IV (4.6.1): 09 food rations (05 port/04 starboard) are wasted. Provide proof of purchase to the USCG prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2008
Resolution: Received receipt of purchase and delivery of 09 food rations.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 18 October 2005
Resolved
Code 0230 - SOLAS Cargo Ship Safety Equipment Certificate provided for 27 crew members and the vessel wants to sail with 29 crew members [name withheld] is scheduled to attend vessel prior to departure and attest to the capacity of the life saving equipment and amend the certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2005
Resolution: Received Class Survey by fax stating it was determined the previous certificate was a typographical error and a new certificate has been issued.
Fire Fighting › Structural - B Class Divisions › Store-rooms
Issued 6 October 2004
Resolved
Crew has made storerooms on upper deck and decks "A" and "B", rooms have been installed in void spaces with wooden doors. Class to approve the installation of these spaces and doors to ensure that they conform to SOLAS II-2 44.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 14 October 2004
Resolution: Recieved class report from DNV # 54140491, 10/07/2004, attesting to approval of spaces
Deck/Cargo › Mooring/Anchoring › Winch
Issued 6 October 2004
Resolved
Coal dust is being drawn into the steering space, and this dust is being drawn into the electric motors for the hydraulic pumps, which operate the aft mooring deck winches. Class to examine this arrangement and ensure that this will not effect the operation of the motors, so not to cause a failure.
Action required: 705 - Other - as specified
Due 6 November 2004
Resolved 14 October 2004
Resolution: Recieved class report from DNV # 54140491, 10/07/2004, ensuring air filters fitted in air supply duct will not effect operation of motors.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 30 July 2004
Resolved
Vessel's self unloader cargo conveyor boom failed and wrecked across deck and pier. Wreckage to be removed by commercial salvage with salvage plan approved by USCG prior to commencing work on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 5 August 2004
Resolution: DNV has atttested to all wreckages being successfully removed this date with no damages to hull or surrounding vessel structures. The vessel has been declared fit for continued route and service this date.
Construction/Loadline › Structures › Superstructure
Issued 30 July 2004
Resolved
Vessel must complete a special survey by class surveyor prior to departing the port of NY to attest to fitness of vessel for continued route and service after boom wreckage is removed from vessel by commercial salvage company.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 5 August 2004
Resolution: DNV has atttested to all wreckages being successfully removed this date with no damages to hull or surrounding vessel structures. The vessel has been declared fit for continued route and service this date.
Stability › Intact Righting Energy › General
Issued 30 July 2004
Resolved
Vessel must remain securely moored at curent berthing location and monitor mooring arrangement and pollution prevention booms until such time as all cargo boom wreckage has been removed from the vessel by commerical salvage company.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 5 August 2004
Resolution: DNV has atttested to all wreckages being successfully removed this date with no damages to hull or surrounding vessel structures. The vessel has been declared fit for continued route and service this date.
Navigation › Collision/Grounding Avoidance
Issued 5 August 2002
Resolved
Radar on port side of bridge inoperable. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2002
Resolved 6 August 2002
Resolution: Received Technition report stating that temporary repairs had been made. Vessel is being issued new COTP order to depart the Port of Bridgeport, CT. and will be required to have permenant repairs made prior to next U.S. voyage.