Inspection history · 20
17 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8269590
15 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7896132
16 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7824425
6 October 2022
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7572975
21 October 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7337803
7 June 2019
MTSA/ISPS Verification · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6706515
27 March 2019
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6650828
20 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6485450
12 June 2018
MTSA/ISPS Verification · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6435572
22 March 2018
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6377142
21 February 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6358740
18 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6298745
4 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6298738
17 August 2017
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6243573
30 May 2017
DAPI Audit · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6160107
29 March 2017
Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6112209
13 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5939574
9 June 2016
MTSA/ISPS Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5902125
3 June 2016
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5896513
28 March 2016
Internal Structural Exam · Drydock Exam · Examination of Repairs · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5842280
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 March 2019
Resolved
Make permanent repairs to crack/hole in port side quarter at sheer.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: Properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 March 2019
Resolved
Make permanent repairs to (03) holes found on starboard hull inboard side approximately 15' from stern.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: Holes properly clad welded.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 March 2019
Resolved
Make permanent repairs to wastage/holes identified by VISR inside of port side hull outboard side sheer below deck.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2019
Resolution: Holes properly clad welded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 27 March 2019
Resolved
Make permanent draft markings at each end of vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2019
Resolution: Draft marks added.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 March 2019
Resolved
Witnessed several wiring modifications and electrical hazards posing severe risk of fire and or electrical shock in both engine rooms and lazarettes. Provide approved electrical plans as well as electrical survey by a certified marine electrician attesting to compliance to the approved electrical plans.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: Incorrect wiring removed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2019
Resolved
Both engine rooms and lazarettes had excessive oil and oily residues in bilge as well as on electrical equipment and batteries. Remove oily residues and degrease all electrical equipment.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: Spaces cleaned of excess oil.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2019
Resolved
Portable fire extinguisher found to be discharged. Provide fire service report for all portable and fixed fire extinguishing equipment onboard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: All fire equipment servied by Caribe Supply.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2019
Resolved
Make vessel available for in service inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 May 2019
Resolution: Completed.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 12 June 2018
Resolved
Prove proper operation of fire detection system. Main deck accomodation space fire detection showing fault. Vessel is restricted to 150 passengers until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 1 May 2019
Resolution: At owner's request vessel permanetly dropped to a maximum of 150 passengers and sub chapter T.
Engineering › Bilge Water Management System › Pump
Issued 12 June 2018
Resolved
Prove proper operation of bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2018
Resolved 14 June 2018
Resolution: Vessel demonstrated proper operations.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2018
Resolved
Provide updated Coast Pilot [name withheld] and Tide Tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 14 June 2018
Resolution: Vessel provided current publications.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2018
Resolved
Prove proper operation of port side engine room high bilge alarm indicator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 14 June 2018
Resolution: Vessel replaced bulb and showed operation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 June 2018
Resolved
Attach ring buoy light with 3-6' line and clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 14 June 2018
Resolution: Vessel provided line and clip.
Fire Fighting › Fire Hoses › Connections
Issued 12 June 2018
Resolved
Provide spanner wrench at each fire hydrant.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 July 2018
Resolution: Vessel provided spanner wrenches.
Construction/Loadline › Hull › Side Shell
Issued 22 March 2018
Resolved
Make permanent repairs to crack found on starboard quarter.
Action required: 705 - Other - as specified
Resolved 23 March 2018
Resolution: Crack ground out and welded.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 22 March 2018
Resolved
Replace missing SFP on port side exhaust piping in lazarette.
Action required: 705 - Other - as specified
Resolved 12 June 2018
Resolution: SPF replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 March 2018
Resolved
Make permanent repairs to damaged deck railing on bow.
Action required: 705 - Other - as specified
Resolved 12 June 2018
Resolution: Rails properly welded.
Construction/Loadline › Structures › Superstructure
Issued 22 March 2018
Resolved
Make permanent repairs to hole found in superstructure just above sheer on port side amidship. Minimum 18"x18" insert.
Action required: 705 - Other - as specified
Resolved 23 March 2018
Resolution: 18x18 insert welded in place.
Communications › Radio Communications › EPIRB
Issued 4 October 2017
Resolved
Provide operable EPIRB ina proper float free arrangement.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 18 October 2017
Resolution: EPIRB installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 October 2017
Resolved
Provide new antennas for VHF radios.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 October 2017
Resolved 18 October 2017
Resolution: VHF radios repaired.
Electrical › Electric Supply System (service) › Battery Charger
Issued 4 April 2017
Resolved
Replace temporary non-marine grade battery chargers for house batteries with a permanant marine grade battery charger.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 13 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 March 2017
Resolved
Provide a permanent repair or renewal of the wasted areas on Stbd MDE exhaust piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 13 April 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 March 2017
Resolved
Conduct Optest in presence of Coast Guard Marine Inspector to verify the new shaft seals, hydraulic steering, fuel system leaks, and exhaust repairs.
Action required: 705 - Other - as specified
Due 4 July 2017
Resolved 13 April 2017
Communications › Alarms/Indicators › Fire Alarm
Issued 10 June 2016
Resolved
Properly mount broken heat detector in port side engine room.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 July 2016
Resolution: Heat detector properly mounted.
Electrical › Electric Supply System (service) › Battery Charger
Issued 10 June 2016
Resolved
Properly mount broken battery chargers in both port and starboard side lazarettes.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Battery chargers mounted.
Engineering › Fuel Oil Service System › Piping
Issued 10 June 2016
Resolved
Provide flame screens for fuel tank vent piping in way of center fuel tank on the port side.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 July 2016
Resolution: Flame screens installed on fuel vent pipe.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 10 June 2016
Resolved
Provide service reports for all (03) Inflatable Buoyant apparatus.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 July 2016
Resolution: Witnessed service reports for IBAs.
Lifesaving › Lifefloat › Markings
Issued 10 June 2016
Resolved
Properly mark life floats and lifefloat paddles.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Lifefloats properly marked.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 June 2016
Resolved
Repair or replace electrical outlet in main cabin on the starboard side, aft.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Outlet repaired.
Stability › Severe Wind/Roll › General
Issued 10 June 2016
Resolved
Secure vending machines to prevent movement.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Vending machines secured with cargo straps.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 10 June 2016
Resolved
Provide shackles for IBA weaklinks.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Shackles installed.
Engineering › Fuel Oil Service System › Valve
Issued 10 June 2016
Resolved
Properly placard emergency fuel shut-off valves.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Valves properly labeled.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 June 2016
Resolved
Properly mount all high-water alarm switches.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Switches secured.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 June 2016
Resolved
Repair or replace junction box in way of bow air conditioning unit cabling.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 June 2016
Resolution: Junction box replaced.
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 June 2016
Resolved
investigate, diagnose and correct steering system hydraulic "hammering."
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 13 July 2016
Resolution: Steering hydraulics found to be working satisfactorily.
Communications › Alarms/Indicators › Fire Alarm
Issued 6 June 2016
Resolved
Prove proper operation of fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: System properly operating.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 June 2016
Resolved
Provide service report for fixed CO2 system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 10 June 2016
Resolution: System properly insptected.
Construction/Loadline › Hull › Bottom Plating
Issued 28 March 2016
Resolved
Make bottom plating in port side #2 compartment where pitted in way of transducer.
Action required: 705 - Other - as specified
Resolved 30 March 2016
Resolution: Operator cropped out the pitted area and inserted new bottom plating.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 28 March 2016
Resolved
Prove proper operation of through hull valves servicing the main engines on port and starboard sides, generator valve and bilge valve in starboard steering compartment.
Action required: 705 - Other - as specified
Resolved 30 March 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 28 March 2016
Resolved
Prove operation of sewage ball valve starboard side.
Action required: 705 - Other - as specified
Resolved 29 March 2016