Records from 2003 to 2026. Most recent: inspection, 23 April 2026.
Inspection history · 43
23 April 2026
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8332491
12 February 2025
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8078520
18 December 2024
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8048839
24 November 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039189
4 October 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8014289
22 February 2024
Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7869245
7 March 2023
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7646180
10 March 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7409287
4 March 2021
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7149017
1 March 2021
Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7148266
12 November 2019
Internal Structural Exam · Construction Oversight · In-Service Inspection · COI Inspection · Administrative Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6855048
18 April 2019
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6753033
18 April 2018
COI Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6393529
1 August 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6223799
25 February 2016
MTSA Verification · MARPOL Annex I Examination · Periodic Inspection · MARPOL Annex VI Survey · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5825813
7 July 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5177136
7 July 2015
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5178520
23 March 2015
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5088816
22 July 2014
MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4924791
16 July 2012
MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4380454
27 April 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4308197
17 April 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4288766
25 March 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3705341
15 March 2010
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3695998
13 May 2009
Annual Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3473343
28 April 2008
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3192279
24 April 2008
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3176974
15 May 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2930913
8 May 2007
SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175999
18 April 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2925000
4 April 2007
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2901398
5 March 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2882141
2 March 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2880726
17 August 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2752302
12 July 2006
SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175934
30 March 2006
MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2615506
25 October 2005
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2522022
12 May 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2365778
24 March 2005
MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2318586
21 September 2004
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2201328
20 July 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2139857
16 April 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2055516
25 April 2003
Internal Structural Exam · Hull Examination · Cargo Tank Internal · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1811002
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2024
Resolved
Each pressure vessel listed on the COI that is fitted with a manhole or other inspection opening so it can be satisfactorily examined internally, must be opened for internal examination every 5 years.
VSL requested to extend the internal pressure vessel inspection to align with the COI expiration date (17DEC24).
VSL's pressure vessel internal inspection has be extended to 17DEC24. VSL is required to have the pressure vsl internal inspected conducted no later than 17DEC24 (COI expiration date).
46 CFR 61.10-5(b)(2)
705C due at 17DEC24/COI date
Action required: 705 - Other - as specified
Due 17 December 2024
Resolved 17 December 2024
Resolution: Conducted internal inspection of pressure vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2022
Resolved
Sidelights shall have an intensity so as to be seen at a
minimum range of 3 miles. The port bow sidelight had
diminished intensity as a result of the lamp being too
high in the fixture. Provide corrective actions. Vessel
will use portable sidelight as mitigating factor while
this sidelight is out of service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 17 March 2022
Resolution: Light has had proper parts installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 March 2021
Resolved
Significant damage identified in aft rake, starboard side during ISE inspection below the waterline. C/R as marked prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 31 March 2021
Resolved 10 March 2021
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 1 August 2017
Resolved
Install required stud in the Port Side Vapor Control Flange at the manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Required stud is installed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 August 2017
Resolved
Repair electrical ground as indicated on #2 generator switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Ground was located in way of the forward starboard navigation light, the plug was replaced clearing the ground as previously indicated by the switchboard ground detector.
Construction/Loadline › Markings › Load Line Mark
Issued 1 August 2017
Resolved
Freeboard measurement on the special service loadline certificate issued by ABS on 29May2013 is not as listed on the ABS Stability Letter dated 25Feb2003. Confirm accuracy of both documents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 8 September 2017
Resolution: Received copy of updated Special Service Load Line Certificate dated 05Sep2017, expires 24April2018.
Engineering › Compressed Air System (start air) › Piping
Issued 1 August 2017
Resolved
Make permanent repairs to 1 1/2" service air piping; aft of the stbd cargo pump house & below the entrance to the port cargo pump house. Once repairs are completed, conduct a 1 1/2 MAWP hydrostatic test of all exterior service air piping to the satisfaction af an attending marine inspector. Until corrected, the exterior service air piping must remain secured with no pressure in the system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Approximately 100' of sevice air piping was replaced using schedule 40 A53 1 1/2". Piping was leak tested using nitorgen at 225 psi.
Construction/Loadline › Hull › Stiffener
Issued 25 February 2016
Resolved
Replace transverse stiffener in 1STBD, Bay 6 and 4PORT, Bay 8 as marked.
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 29 February 2016
Resolution: Vessel renewed both stiffeners as marked. Visual inspection of welds SAT.
Construction/Loadline › Hull › Transverse Frame
Issued 25 February 2016
Resolved
Grind and reweld marked areas in 1 STBD Bay 5, 3 STBD Bay 2 and 4, 4STBD Bay 2. Drill stop, grind and reweld marked area in 2PORT Bay 8.
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 29 February 2016
Resolution: All areas rewelded. Visual inspection of welds SAT.
Electrical › Electric Supply System (service) › Battery Charger
Issued 7 July 2015
Resolved
Permanently wire both battery chargers is in accordance with electrical plan. 46 CFR 111.15-30, 111.01-9
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 10 July 2015
Resolution: Battery chargers removed from generator battery banks and origional alternators install to manufacturer spec.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 7 July 2015
Resolved
ABS documents need to be issued, restricted to domestic route. 46CFR 31.25-1
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 10 July 2015
Resolution: ABS documents endorsed by attending ABS surveyor.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2015
Resolved
Remove permanently installed extension cords in galley. 46CFR 111.79
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 10 July 2015
Resolution: Permenantly installed extension cord removed from galley/accomadations.
Documentation › Markings/Placards › Warning Signs
Issued 7 July 2015
Resolved
Ensure bravo flag is painted red. 46CFR35.30-1
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 8 July 2015
Resolution: Corrected on the spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2015
Resolved
Port and Starboard watertight service lights have water intrusion. Repair to the satisfaction of the attending CG Marine Inspector. 46CFR111.75-20(d)(1)
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Drained water and re-sealed lights.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 July 2015
Resolved
Distribution panel on generator switchboard is missing a breaker. Must blank off unused spot to the satisfaction of the attending CG Marine Inspector. 46CFR111.50-5
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Missing breaker was blanked off.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 July 2015
Resolved
Provide proper installation of generator battery casing and cover on port and starboard side to the satisfaction of the attending CG Marine Inspector. 46CFR111.15-5(d)
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Removed strap in bag and used strap to secure cover to battery.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 7 July 2015
Resolved
Renew missing label for emergency stop for both cargo pumps forward to the satisfaction of the attending CG Marine Inspector. 46CFR32.50-35
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Emergency stop forward was properly labeled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 July 2015
Resolved
Renew deteriorated and missing deck railing/chain on port and starboard side to the satisfaction of the attending CG Marine Inspector. 46CFR32.02-10
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Installed chains of at least 15 inches apart.
Lifesaving › Inflatable Liferafts › Markings
Issued 7 July 2015
Resolved
Replace all weathered life saving markers, including the liferaft and EPIRB decals to the satisfaction of the attending CG Marine Inspector. 46CFR199.178
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Replaced weathered decals.
Deck/Cargo › Vapor Control Systems › Manual Isolation Valve
Issued 7 July 2015
Resolved
Number five port cargo tank transfer valve leaking cargo and fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Packing was tightened on valve. Valve no longer leaks.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 July 2015
Resolved
Vertical trunks 1, 2, 4, and 5 are leaking cargo fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Seal was replaced. Hatches do not leak.
Deck/Cargo › Holds/Tanks › Ullage
Issued 7 July 2015
Resolved
Port and starboard ullage hatches are leaking cargo fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Leaking hatches had seals replaced. No leaks could be found.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 7 July 2015
Resolved
Port and starboard liquid level indicators are leaking cargo fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Liquid level stick tubes no longer leak.
Deck/Cargo › Cargo Stowage › General
Issued 26 April 2012
Resolved
Vessel is prohibited from carrying the following cargoes until a satisfactory cargo tank internal exam is conducted by the attending USCG MI: Crude hydrocarbon feedstock (CHG), Hydrocarbon 5-9 (HFN), Styrene (Crude)(STX), Vinyl Neodecanate (VND).
Action required: 705 - Other - as specified
Resolved 30 July 2012
Resolution: Vessel received new CAA, removing these four cargoes.
Construction/Loadline › Hull › Double Hull
Issued 25 October 2005
Resolved
Make proper repairs to sideshell IWO SSL no. 5 & 7 (from top), no.1 port void IWO damaged area (8ft x 6ft). To be completed at next drydock.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 30 March 2006
Construction/Loadline › Hull › Double Hull
Issued 25 October 2005
Resolved
Make proper repairs to damaged internal structures IWO damage in no. 1 port void, bay no. 4. To be completed at next drydock.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 30 March 2006