DOUBLE SKIN 52

DOUBLE SKIN 52 is a 2003 freight barge. The Coast Guard has recorded 43 inspections since 2003, most recently in April 2026, along with 26 deficiencies, 1 operational control and 2 casualty investigations between 2010 and 2012.

Records from 2003 to 2026. Most recent: inspection, 23 April 2026.

Built
2003
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 23 April 2026
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 21 calendar years (2003–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

589372
Flag
UNITED STATES
Maury page id
psix-589372

Documentation record

Registered dimensions (L × B × D)362.5 ft × 62.0 ft × 24.0 ft
Registered tonnagegross 4,530 / net 4,530
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2003
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4530 - Simplified, Gross Ton
4530 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WYE RIVER Towing Vessel · MISLE 936474 · 27 April 2012 · activity 4308197

Inspection history · 43

23 April 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8332491
12 February 2025 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8078520
18 December 2024 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8048839
24 November 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039189
4 October 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8014289
22 February 2024 Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7869245
7 March 2023 Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7646180
10 March 2022 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7409287
4 March 2021 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7149017
1 March 2021 Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7148266
12 November 2019 Internal Structural Exam · Construction Oversight · In-Service Inspection · COI Inspection · Administrative Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6855048
18 April 2019 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6753033
18 April 2018 COI Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6393529
1 August 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6223799
25 February 2016 MTSA Verification · MARPOL Annex I Examination · Periodic Inspection · MARPOL Annex VI Survey · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5825813
7 July 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5177136
7 July 2015 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5178520
23 March 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5088816
22 July 2014 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4924791
16 July 2012 MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4380454
27 April 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4308197
17 April 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4288766
25 March 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3705341
15 March 2010 Annual Inspection · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3695998
13 May 2009 Annual Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3473343
28 April 2008 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3192279
24 April 2008 Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3176974
15 May 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2930913
8 May 2007 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175999
18 April 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2925000
4 April 2007 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2901398
5 March 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2882141
2 March 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2880726
17 August 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2752302
12 July 2006 SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175934
30 March 2006 MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2615506
25 October 2005 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2522022
12 May 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2365778
24 March 2005 MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2318586
21 September 2004 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2201328
20 July 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2139857
16 April 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2055516
25 April 2003 Internal Structural Exam · Hull Examination · Cargo Tank Internal · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1811002

Deficiency record · 26

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2024 Resolved
Each pressure vessel listed on the COI that is fitted with a manhole or other inspection opening so it can be satisfactorily examined internally, must be opened for internal examination every 5 years. VSL requested to extend the internal pressure vessel inspection to align with the COI expiration date (17DEC24). VSL's pressure vessel internal inspection has be extended to 17DEC24. VSL is required to have the pressure vsl internal inspected conducted no later than 17DEC24 (COI expiration date). 46 CFR 61.10-5(b)(2) 705C due at 17DEC24/COI date
Action required: 705 - Other - as specified
Due 17 December 2024
Resolved 17 December 2024
Resolution: Conducted internal inspection of pressure vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2022 Resolved
Sidelights shall have an intensity so as to be seen at a minimum range of 3 miles. The port bow sidelight had diminished intensity as a result of the lamp being too high in the fixture. Provide corrective actions. Vessel will use portable sidelight as mitigating factor while this sidelight is out of service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 17 March 2022
Resolution: Light has had proper parts installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 March 2021 Resolved
Significant damage identified in aft rake, starboard side during ISE inspection below the waterline. C/R as marked prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 31 March 2021
Resolved 10 March 2021
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 1 August 2017 Resolved
Install required stud in the Port Side Vapor Control Flange at the manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Required stud is installed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 August 2017 Resolved
Repair electrical ground as indicated on #2 generator switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Ground was located in way of the forward starboard navigation light, the plug was replaced clearing the ground as previously indicated by the switchboard ground detector.
Construction/Loadline › Markings › Load Line Mark
Issued 1 August 2017 Resolved
Freeboard measurement on the special service loadline certificate issued by ABS on 29May2013 is not as listed on the ABS Stability Letter dated 25Feb2003. Confirm accuracy of both documents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 8 September 2017
Resolution: Received copy of updated Special Service Load Line Certificate dated 05Sep2017, expires 24April2018.
Engineering › Compressed Air System (start air) › Piping
Issued 1 August 2017 Resolved
Make permanent repairs to 1 1/2" service air piping; aft of the stbd cargo pump house & below the entrance to the port cargo pump house. Once repairs are completed, conduct a 1 1/2 MAWP hydrostatic test of all exterior service air piping to the satisfaction af an attending marine inspector. Until corrected, the exterior service air piping must remain secured with no pressure in the system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 11 September 2017
Resolution: Approximately 100' of sevice air piping was replaced using schedule 40 A53 1 1/2". Piping was leak tested using nitorgen at 225 psi.
Construction/Loadline › Hull › Stiffener
Issued 25 February 2016 Resolved
Replace transverse stiffener in 1STBD, Bay 6 and 4PORT, Bay 8 as marked.
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 29 February 2016
Resolution: Vessel renewed both stiffeners as marked. Visual inspection of welds SAT.
Construction/Loadline › Hull › Transverse Frame
Issued 25 February 2016 Resolved
Grind and reweld marked areas in 1 STBD Bay 5, 3 STBD Bay 2 and 4, 4STBD Bay 2. Drill stop, grind and reweld marked area in 2PORT Bay 8.
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 29 February 2016
Resolution: All areas rewelded. Visual inspection of welds SAT.
Electrical › Electric Supply System (service) › Battery Charger
Issued 7 July 2015 Resolved
Permanently wire both battery chargers is in accordance with electrical plan. 46 CFR 111.15-30, 111.01-9
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 10 July 2015
Resolution: Battery chargers removed from generator battery banks and origional alternators install to manufacturer spec.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 7 July 2015 Resolved
ABS documents need to be issued, restricted to domestic route. 46CFR 31.25-1
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 10 July 2015
Resolution: ABS documents endorsed by attending ABS surveyor.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2015 Resolved
Remove permanently installed extension cords in galley. 46CFR 111.79
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 10 July 2015
Resolution: Permenantly installed extension cord removed from galley/accomadations.
Documentation › Markings/Placards › Warning Signs
Issued 7 July 2015 Resolved
Ensure bravo flag is painted red. 46CFR35.30-1
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 8 July 2015
Resolution: Corrected on the spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2015 Resolved
Port and Starboard watertight service lights have water intrusion. Repair to the satisfaction of the attending CG Marine Inspector. 46CFR111.75-20(d)(1)
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Drained water and re-sealed lights.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 July 2015 Resolved
Distribution panel on generator switchboard is missing a breaker. Must blank off unused spot to the satisfaction of the attending CG Marine Inspector. 46CFR111.50-5
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Missing breaker was blanked off.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 July 2015 Resolved
Provide proper installation of generator battery casing and cover on port and starboard side to the satisfaction of the attending CG Marine Inspector. 46CFR111.15-5(d)
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Removed strap in bag and used strap to secure cover to battery.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 7 July 2015 Resolved
Renew missing label for emergency stop for both cargo pumps forward to the satisfaction of the attending CG Marine Inspector. 46CFR32.50-35
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Emergency stop forward was properly labeled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 July 2015 Resolved
Renew deteriorated and missing deck railing/chain on port and starboard side to the satisfaction of the attending CG Marine Inspector. 46CFR32.02-10
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Installed chains of at least 15 inches apart.
Lifesaving › Inflatable Liferafts › Markings
Issued 7 July 2015 Resolved
Replace all weathered life saving markers, including the liferaft and EPIRB decals to the satisfaction of the attending CG Marine Inspector. 46CFR199.178
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Replaced weathered decals.
Deck/Cargo › Vapor Control Systems › Manual Isolation Valve
Issued 7 July 2015 Resolved
Number five port cargo tank transfer valve leaking cargo and fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Packing was tightened on valve. Valve no longer leaks.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 July 2015 Resolved
Vertical trunks 1, 2, 4, and 5 are leaking cargo fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Seal was replaced. Hatches do not leak.
Deck/Cargo › Holds/Tanks › Ullage
Issued 7 July 2015 Resolved
Port and starboard ullage hatches are leaking cargo fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Leaking hatches had seals replaced. No leaks could be found.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 7 July 2015 Resolved
Port and starboard liquid level indicators are leaking cargo fumes, identify cause and make repairs to the satisfaction of the attending CG Marine Inspector. 46CFR153.935
Action required: 705 - Other - as specified
Resolved 8 July 2015
Resolution: Liquid level stick tubes no longer leak.
Deck/Cargo › Cargo Stowage › General
Issued 26 April 2012 Resolved
Vessel is prohibited from carrying the following cargoes until a satisfactory cargo tank internal exam is conducted by the attending USCG MI: Crude hydrocarbon feedstock (CHG), Hydrocarbon 5-9 (HFN), Styrene (Crude)(STX), Vinyl Neodecanate (VND).
Action required: 705 - Other - as specified
Resolved 30 July 2012
Resolution: Vessel received new CAA, removing these four cargoes.
Construction/Loadline › Hull › Double Hull
Issued 25 October 2005 Resolved
Make proper repairs to sideshell IWO SSL no. 5 & 7 (from top), no.1 port void IWO damaged area (8ft x 6ft). To be completed at next drydock.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 30 March 2006
Construction/Loadline › Hull › Double Hull
Issued 25 October 2005 Resolved
Make proper repairs to damaged internal structures IWO damage in no. 1 port void, bay no. 4. To be completed at next drydock.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 30 March 2006

Casualty record · 2

25 March 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3705341
27 April 2012Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4308197
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.