Records from 2002 to 2024. Most recent: inspection, 20 November 2024.
Documentation record
Registered dimensions (L × B × D)121.9 ft × 42.0 ft × 21.8 ft
Registered tonnagegross 265 / net 180
ITC dimensions (L × B × D)121.9 ft × 42.0 ft × 21.8 ft
ITC tonnagegross 963 / net 288
BuilderMARINETTE MARINE CORPORATION · MARINETTE, WI, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it265 - Regulatory (Subpart C or D), Gross Ton
963 - Convention (Subpart B), Gross Ton
180 - Regulatory (Subpart C or D), Net Ton
288 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 56
20 November 2024
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8034974
3 October 2024
Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8013949
14 August 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981411
8 August 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7763192
26 September 2022
MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7560421
26 August 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7544334
25 July 2022
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7512131
20 July 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7492439
19 May 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7504059
17 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7433925
19 July 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7261615
12 February 2020
MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6911151
20 March 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6645942
12 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6559959
4 December 2017
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6317876
28 September 2017
MTSA/ISPS Verification
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6267480
1 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5818557
28 October 2015
Administration
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5758895
16 April 2015
MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5104420
17 October 2014
Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5012816
18 October 2013
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4736860
9 June 2013
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4615109
16 November 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4492075
9 October 2012
MTSA/ISPS Verification · MARPOL Annex IV Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4457411
13 April 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4286240
24 October 2011
MARPOL Annex IV Survey · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4175737
17 October 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4170101
19 January 2011
MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3929345
12 August 2010
Deficiency Check · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3822021
11 March 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3694384
7 December 2009
MTSA/ISPS Verification · MARPOL Annex IV Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3650482
28 October 2008
Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3350835
20 July 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3274699
27 December 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3121625
27 December 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3137633
11 October 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3077687
19 September 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3062347
20 August 2007
MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3033962
28 July 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3028777
2 March 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2882736
1 December 2006
Uninspected Other
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2838391
15 September 2006
MTSA/ISPS Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2779047
30 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2695979
30 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2695983
18 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2537071
6 November 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2242126
31 October 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2231956
2 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2184010
28 June 2004
MTSA/ISPS Verification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2109525
2 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2000938
24 September 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1911992
30 April 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1783916
16 February 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1752216
11 February 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1794180
9 February 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1765979
16 October 2002
In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1690813
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2022
Resolution: Vessel completed satisfactory COI exam and has been issued a valid COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 April 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board the Vessel under normal and emergency conditions. Vessel is experiencing a malfunction in the main steering gear. Complete repairs to the satisfaction of class prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2022
Resolved 19 April 2022
Resolution: Received ABS report attesting to satisfactory repairs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. It was reported that the vessels emergency steering pump was not functioning as intended during pre-departure checks. Vessel is authorized a single transit to the lower fina anchorage in Port Arthur to conduct repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2022
Resolved 19 April 2022
Resolution: Received report from ABS attesting to satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2021
Resolved
Damage to bearings and cylinder found on No. 12 cylinder of Port Main Engine. Vessel to continue root cause analysis and repair as appropriate to bring Port Main Engine back into safe operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2021
Resolved 3 August 2021
Resolution: ABS provided report confirming cylinder was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 October 2018
Resolved
LENGTH DIFF: greater/smaller than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 March 2019
Resolution: Length broadcast is correct
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 October 2013
Resolved
Vessel to conduct repair of faulty x-band radar prior to departure from port. Vessel to notify Coast Guard MSU Portland Inspection office upon completion of repairs. 33CFR164.72
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2013
Resolved 18 October 2013
Resolution: Received technician service report - all sat.