Records from 2002 to 2026. Most recent: inspection, 1 March 2026.
Inspection history · 56
1 March 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8325243
3 February 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8306102
9 August 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8205948
27 May 2025
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8139853
12 May 2025
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8134924
2 December 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8042087
21 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7940181
25 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7704888
24 January 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7629234
12 April 2022
Drydock Exam · Cargo Tank Internal · COI Inspection · MARPOL Annex IV Survey · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7400758
5 April 2021
Annual Inspection · MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7169233
16 March 2020
Internal Structural Exam · Periodic Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6928260
25 June 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6725354
10 June 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6703809
21 February 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6366060
6 December 2017
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6319902
8 March 2017
MARPOL Annex IV Survey · COI Inspection · Internal Structural Exam · MARPOL Annex I Examination · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6101469
21 February 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6091742
8 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5838546
19 March 2015
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5087034
2 November 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5016496
9 July 2014
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4916783
7 June 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4884385
11 November 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4482584
24 August 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4421122
1 June 2012
Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4399455
21 May 2012
Cargo Tank Internal · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4317770
19 April 2012
COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4289071
16 April 2012
Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4288322
14 August 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4115510
29 June 2011
MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex IV Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4073884
28 July 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3808235
24 May 2010
Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3732470
19 May 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3746346
17 September 2009
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3596656
15 May 2009
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3518353
27 April 2009
MARPOL Annex IV Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3456587
12 March 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3432546
2 February 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3420952
11 July 2008
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3264396
22 April 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3191201
22 October 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3085416
4 May 2007
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2922301
19 April 2007
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2911209
15 April 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2911176
13 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2711564
11 May 2006
Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2646535
10 May 2005
Annual Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2354431
2 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2183999
28 June 2004
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2353504
15 April 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2044475
5 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2000926
24 September 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1911992
15 August 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1877225
8 May 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1788674
2 April 2002
Internal Structural Exam · Construction Oversight · Hull Examination · Initial Certification · Cargo Tank Internal
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1600041
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2025
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges: (v) A white, red, green or yellow all-round light, 3 miles. The port side navigation light was not operational at the time of inspection. 33CFR83.22(a)&(v)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2025
Resolved 30 May 2025
Resolution: Bulb replaced. Operationally tested. All Sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 May 2025
Resolved
xcept as provided in paragraph (d) of this section, no person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel or facility operator, as appropriate, tests and inspects the equipment in accordance with paragraphs (b), (c) and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section..(f)(3) The frequency of the tests and inspections required by this section must be: For vessels, annually or as part of the biennial and mid-period inspections. The calibration of the pressure gauges at the transfer
station did not have a record of tests or inspections
readily accessible. Provide documentation of required
testing of equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2025
Resolved 6 June 2025
Resolution: Calibration of pressure gauges were conducted and report of test confirmed. All Sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 May 2025
Resolved
Red warning signals: During transfer of bulk cargo while fast to a dock, a red signal (flag by day and electric lantern at night) shall be so placed that it will be visible on all sides. While transferring bulk cargo at anchor, a red flag only shall be displayed. The red electric lantern (light) was not operational during the time of inspection. 46 CFR 35.30-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 30 May 2025
Resolution: Bulb replaced for bravo light and tested. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2025
Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space. The inert gas generator space was missing non-conductive matting installed in front of the blower switchboard.
46 CFR 111.30-11
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 May 2025
Resolved 29 May 2025
Resolution: Non conducting deck coverings were placed in front of the blower switch board. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2025
Resolved
All lifesaving appliances and arrangements on tank vessels must be in accordance with sub chapter W (Lifesaving Appliances and Arrangements) of this chapter... Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The light provided on the lifebuoy, starboard side, aft of the transfer station was not operational.
46 CFR 31.36-1
46 CFR 199.190(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 29 May 2025
Resolution: The light attached to the life buoy was replaced. Tested; All Sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2023
Resolved
Electrical installations on vessels must ensure: maintenance of system integrity through compliance with the applicable system requirements (NEC) to which plan review has been approved. Vessels cargo deck area explosion proof/intrinsically safe fittings found painted/taped over obscuring the approval data and rendering their condition in question. Close up inspection by a qualified person to be conducted to ascertain condition of equipment and fittings within the hazardous area. 46 CFR 111.01-1(a)(3)
46 CFR 111.105-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2023
Resolution: Electricans report provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2023
Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Junction box on the port aft notch area of the barge has a non securing cover for the electrical supply cable from the tug. 46 CFR 111.01(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2023
Resolution: Latch installed for securing the junction box.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 May 2023
Resolved
No cargo tank hatches, ullage holes, or Butterworth plates shall be opened or shall remain open without flame screens.. the ullage opening at cargo hold #6 port was found missing its cover. 46 CFR 35-30.10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 May 2023
Resolution: Ullage cap was found and placed back in service during the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 May 2023
Resolved
The terms, endorsements and conditions set forth on the certificate of inspection shall have the same force as the regulations contained in this sub chapter. Vessel found inconsistently complying with the provisions of conditional occupancy as outlined on the COI and in the operations manual. 46 CFR 31.05-15
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 25 May 2023
Resolution: Review of operations manual and clairifying disucssions held with crew during the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2020
Resolved
Reachrod and vavle found to be seized for forepeak dewatering.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 March 2020
Resolution: Reachrod and vavle freed. Tested operation on dewatering of forepeak from reachrod operation, all sat.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 February 2018
Resolved
Provide completed copy of oil transfer procedures, posted and available for use by personnel involved in transfer procedures. 33CFR155.720-750
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 2 April 2018
Resolution: Vessel POC provided copy of complete transfer procedures for all class 550 barges.
Construction/Loadline › Structures › Superstructure
Issued 21 February 2018
Resolved
Provide detailed report outlining location, length (NDT), and position relative to hazardous locations for each of the seven identifed fractures on the deckhouses.
Due 15 March 2018
Resolved 2 April 2018
Resolution: Vessel provided details as requested; repairs to follow.
Construction/Loadline › Structures › Superstructure
Issued 21 February 2018
Resolved
Make repairs to the deteriorated/holed conduit standpipe for the transfer drive antenna. 46CFR171.122(b)
Due 21 March 2018
Resolved 2 April 2018
Resolution: Cracks were drill stopped, gouged out, and welded. PT conducted prior to repairs and after completed weld repairs; all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 6 December 2017
Resolved
Provide proper operation of the #4 prime mover. All repairs chall be made to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 8 December 2017
Resolution: Replaced #4 PTO bearing.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 19 April 2012
Resolved
PV valves could not be opened for examination as tanks were laden and inerted. All PV valves will be opened and examined at the barge's upcoming drydock.
Due 21 May 2012
Resolved 23 May 2012
Resolution: Inspected PV valves.
Engineering › Pressure Vessel › Weld
Issued 19 April 2012
Resolved
Barge has two pressure vessels which are not listed on the COI. Make available for internal inspection at upcoming drydock. (Safety valves already tested and found to be sat.)
Due 21 May 2012
Resolved 23 May 2012
Resolution: Inspected (visual) pressure vessels satisfactory.
Construction/Loadline › Structures › Rake
Issued 19 April 2012
Resolved
Aft rake had not been opened and gas freed. Make available for internal inspection at next drydock.
Due 21 May 2012
Resolved 23 May 2012
Resolution: Inspected satisfactory.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 April 2009
Resolved
Need to properly fix piping on the Inert Gas System (IGS), noticed that the vessels sea suction piping that draws water from the ballast system had a hole in he piping, discussed the issue with the vessel rep. Representative explained that prior to departure that would cut and re-weld new piping joint.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 15 May 2009
Resolution: IG sea suction piping repaired.
Construction/Loadline › Hull › Hull Plating
Issued 19 April 2007
Resolved
Make temporary watertight repairs to damaged hull plating in the port skeg void aft of the Intercon ladder. Repairs to be made prior to departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2007
Resolved 20 April 2007
Resolution: Temporary repairs made utilizing a 3/8" steel double plate. The doubler plate covered the entire damaged section and provided the needed watertight integrity for the transit to dry dock.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 19 April 2007
Resolved
Repair damaged electrical "tug to barge" shore-tie connection.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2007
Resolved 20 April 2007
Resolution: A new electrical shore tie box was installed and the configuration was changed to allow the tug to disconnect electrically from the barge in a future emergency to prevent this damage from re-occuring.
Construction/Loadline › Hull › Hull Plating
Issued 19 April 2007
Resolved
Make permanent repairs to the damaged section of the port skeg void. Vessel restricted from all cargo operations until repairs are completed. Repairs to be completed NLT 15 MAY 2007 or next dry docking, whichever comes first.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 4 May 2007
Resolution: Vessel Repaired.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 15 May 2002
Resolved
Restricted from Cargo Ops until MSC completes plan review.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2002
Resolution: MSC approval of plans.