BISCAYNE LADY

BISCAYNE LADY is a 2002 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 2002, most recently in May 2026, along with 58 deficiencies and 3 casualty investigations between 2007 and 2020.

Records from 2002 to 2026. Most recent: inspection, 20 May 2026.

Built
2002
Last inspected
20 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8975201 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB2148
590334
Flag
UNITED STATES
366872810
Maury page id
psix-590334

Inspections, by type

…with no type recorded3
Years with a record 24 calendar years (2002–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)103.0 ft × 44.3 ft × 11.4 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)103.0 ft × 44.3 ft × 11.4 ft
ITC tonnagegross 568 / net 194
BuilderAUSTAL USA LLC · MOBILE, AL, UNITED STATES · built 2002
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it568 - Convention (Subpart B), Gross Ton
92 - Regulatory (Subpart C or D), Gross Ton
194 - Convention (Subpart B), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
165 - Dead Weight, Ton
165 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB2148MMSI 366872810 · active · compulsorily equipped · granted 2 August 2022, expires 29 October 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

VENETIAN LADY Passenger (Inspected) · MISLE 859113 · 18 October 2007 · activity 3105226

Inspection history · 45

20 May 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8376963
30 September 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8243209
6 August 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8202031
23 July 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7964357
12 October 2023 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7809772
14 August 2023 Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7772780
7 July 2022 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7499805
14 September 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7311856
20 August 2021 Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7291148
6 August 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7025267
9 January 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6886088
13 August 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6781867
8 August 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6776459
27 February 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6633556
22 August 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6519351
14 August 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6511455
19 July 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6484530
2 March 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6364609
16 August 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6243266
3 August 2017 Internal Structural Exam · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6229430
2 August 2017 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228424
2 March 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6097680
19 October 2016 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6025089
18 August 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5219536
11 August 2015 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5212448
7 October 2014 Annual Inspection · DAPI Audit · MTSA Verification · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5011697
7 June 2012 Excursion Permit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4336368
12 August 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4113150
22 February 2010 MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3681578
10 March 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3430403
29 July 2008 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3284727
23 January 2008 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3132744
19 October 2007 Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3084338
18 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3105226
11 April 2007 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2905688
16 May 2006 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2650354
10 April 2006 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2621503
12 April 2005 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2331797
11 May 2004 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2064563
7 April 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040640
7 April 2004 MTSA Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2053828
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977560
4 October 2003 Plan Review "T" Boat
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1920944
25 November 2002 COI Inspection · Internal Structural Exam · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1710379
21 November 2002 Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1716872

Deficiency record · 58

10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 30 September 2025 Resolved
Each power motor for the main and auxiliary steering gear must have a “motor running” indicator light in the pilothouse, and in the machinery space, that activates when the motor is energized. Vessel has no "motor running" indicator light in the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 8 October 2025
Resolution: Operator installed motor running light in the pilot house.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; MI discovered open electrical junction box in the port fwd void beneath stairwell.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2025
Resolved 8 October 2025
Resolution: e;ecgtrical junction box repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 July 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment,electrical shock. 46 CFR 120.200 Replace cracked outlet on bridge, remove loose wiring in stbd male head, and remove extension cord and replace electrical cord for warmer.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2024
Resolved 25 July 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 July 2024 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Install emergency lighting in freezer compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 25 July 2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2024 Resolved
For portable fire extinguishers... inspections required by chapter 4 of NFPA 10... A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. Create a inspection tag or log for all portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 30 July 2024
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 August 2018 Resolved
AIS data showing zero length or beam/zero draft due to missing length of vessel points from AIS ANT location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 September 2019
Resolution: data points were properly input into AIS to get the correct measurements of the vessel.
Engineering › Bilge Water Management System › Strainer
Issued 18 August 2015 Resolved
Renew emergency bilge strainer under STBD main engine.
Due 20 August 2015
Resolved 20 August 2015
Resolution: Strainer was renewed and replaced in kind.
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 August 2015 Resolved
Prove outboard main engine butterfly valve disc fastening to stem (port main engine water suction)
Due 20 August 2015
Resolved 18 August 2015
Resolution: Corrected same day. Vessel crew members proved proper seal.
Communications › Radio Communications › EPIRB
Issued 7 October 2014 Resolved
Properly replace EPIRB Battery
Due 28 October 2014
Resolved 28 October 2014
Resolution: EPIRB battery replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2014 Resolved
Remove dead end wires from port pump room.
Due 28 October 2014
Resolved 28 October 2014
Resolution: Dead end wires were properly terminated in a receptacle.
Fire Fighting › Fire Pumps › Pressure
Issued 7 October 2014 Resolved
Prove proper operation of the stbd fire pump gauge.
Due 28 October 2014
Resolved 28 October 2014
Resolution: Replaced stbd fire pump gauge.
Electrical › Electric Supply System (service) › Battery Charger
Issued 7 October 2014 Resolved
Properly install battery charger ammeter.
Due 24 November 2014
Resolved 24 November 2014
Resolution: Intalled ammeter on battery chargers.
Construction/Loadline › Penetrations › Valve Flange
Issued 12 August 2011 Resolved
All valves within six inches of the water line are being replaced with new valves (13 total).
Action required: 705 - Other - as specified
Resolved 19 August 2011
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 22 February 2010 Resolved
Prove proper operation of flame failure device.
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 4 March 2010
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 22 February 2010 Resolved
Prove proper indication on the bridge of the main deck port and starboard aft call point.
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 4 March 2010
Communications › Radio Communications › EPIRB
Issued 10 March 2009 Resolved
Provide proof of NOAA registration for EPIRB.
Action required: 705 - Other - as specified
Resolved 25 March 2009
Lifesaving › Lifebuoys › Serviceable
Issued 10 March 2009 Resolved
Properly replace grab line on port bridge wing ring buoy.
Action required: 705 - Other - as specified
Resolved 10 March 2009
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 10 March 2009 Resolved
Provide current deviation table.
Action required: 705 - Other - as specified
Resolved 23 March 2009
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 March 2009 Resolved
Properly paint with contrast in color draft marks forward and aft.
Action required: 705 - Other - as specified
Resolved 23 March 2009
Communications › Public Address System › Loudspeaker
Issued 10 March 2009 Resolved
Make proper repairs to PA speaker on upper deck aft port side.
Action required: 705 - Other - as specified
Resolved 23 March 2009
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 14 February 2008 Resolved
Ensure LPG system is installed IAW 46 CFR 121.240 and ABYC or NFPA.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 29 July 2008
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 14 February 2008 Resolved
Continuous pilot lights are prohibited per 46 CFR 121.240 (d). Provide certification that the current stove meets ABYC or provide a stove without a continuous pilot light.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 29 July 2008
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 14 February 2008 Resolved
Provide a flam failure device on all burners and pilot lights that will prevent gas form flowing to the burner if a flame is present.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 29 July 2008
Electrical › Electric Supply System (service) › Cable
Issued 23 January 2008 Resolved
Secure wires IAW 46 CFR 120.340 (i). When using twist-on type wire nuts ensure connectors are secure and connection is made within an enclosure in sewage pump void/men’s head.
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 1 February 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 January 2008 Resolved
Properly mark lifejacket lockers both P/S side, upper deck IAW 46 CFR 122.604 (f).
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 1 February 2008
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 January 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 1 February 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 23 January 2008 Resolved
Provide company and consortium complete employee list.
Action required: 705 - Other - as specified
Due 6 February 2008
Resolved 1 February 2008
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 23 January 2008 Resolved
Prove proper operation, to a USCG Marine Inspector, that the detection system for the LP system is fully operational and operates IAW MFG instruction.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 29 July 2008
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 19 October 2007 Resolved
Make proper repairs to windows (03 port side) prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2007
Electrical › Electric Generation Source (service) › Conductor
Issued 11 April 2006 Resolved
Remove Dead end wires at starboard Vent Stop Motor.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Fire Fighting › Fire Hoses › Location
Issued 11 April 2006 Resolved
Properly mount cables at starboard Forward Fire Station.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 April 2006 Resolved
Provide latch at Oven Door in Galley
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 April 2006 Resolved
Provide Securing Gear for Stores in Galley.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Engineering › Fuel Oil Service System › Valve
Issued 11 April 2006 Resolved
Provide proper operation of Fuel Shut-offs, no later than Drydock.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 11 April 2006
Engineering › Fuel Oil Service System › Filter
Issued 11 April 2006 Resolved
Provide Flash covers (bowls) and Metal Petcocks on Fuel Filters.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Electrical › Electric Generation Source (service) › Conductor
Issued 11 April 2006 Resolved
Provide Bracing at all Battery Boxes (inside Battery Box).
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Electrical › Electrical Distribution System (service) › Switch
Issued 11 April 2006 Resolved
Provide watertight covers at electrical switches for Fire pump and Fuel pump on Port and Starboard sides.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 11 April 2006 Resolved
Properly attach pull device for fire suppression system in Galley.
Action required: 705 - Other - as specified
Due 12 April 2006
Resolved 11 April 2006
Fire Fighting › Fire Main › Condition
Issued 11 April 2006 Resolved
Repair leak at Fire Main coupling at port side.
Action required: 705 - Other - as specified
Due 12 April 2006
Resolved 11 April 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 April 2006 Resolved
Re-attach Insulation at Starboard engine Room hatch.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Electrical › Electrical Distribution System (service) › Switch
Issued 11 April 2006 Resolved
Replace Broken 110v duplex outlet at Starboard Bar.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 11 April 2006 Resolved
Conduct Monthly fire and Abandonment Drills.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 April 2006 Resolved
Prove proper operation of Fire Alarm panel, pulls and Detectors.
Action required: 705 - Other - as specified
Due 12 April 2006
Resolved 11 April 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 11 April 2006 Resolved
Prove proper operation emergency lighting system.
Action required: 705 - Other - as specified
Due 12 April 2006
Resolved 11 April 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2006 Resolved
Properly attach Float light Lanyard to body of Life ring.
Action required: 705 - Other - as specified
Due 25 April 2006
Resolved 11 April 2006
Lifesaving › Visual Distress Signals (General) › Expired
Issued 11 April 2006 Resolved
Provide a proper Hydrostatic release for EPIRB out of date.
Action required: 705 - Other - as specified
Due 12 April 2006
Resolved 11 April 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 April 2005 Resolved
Portable fire extinguisher not properly mounted. Provide brackets for fire extinguisher to the satisfaction of the attending Marine Inspector.
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Electrical › Electrical Distribution System (service) › Cable
Issued 12 April 2005 Resolved
Improper cable runs into main switchboard, missing stuffing tube. Make permanent and proper repairs.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2005 Resolved
Cable runs out of engine rooms chaffing, make permanent and proper repairs.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2005 Resolved
Improper radius on cables in bow thruster compartment, correct radius as much as possible and provide chaffing material. Make permanent and proper repairs.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Fire Fighting › Grease Extraction Hood › General
Issued 12 April 2005 Resolved
Label door to fire controls outside galley "Galley range fire fighting controls, do not block door." Make permanent and proper repairs.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2005 Resolved
Improper wiring to decorative lighting on stairways, make permanent and proper repairs.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Fire Fighting › Ventilation Systems › Ducts
Issued 12 April 2005 Resolved
Several Fire Damper closed permanently and not indicating on the panel. Reconnect indicators or label panel as closed and have the light indicate properly.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 19 May 2005
Resolution: Cleared via e-mail w/ photos
Engineering › Bilge Water Management System › Piping
Issued 11 May 2004 Resolved
Prove proper operation of bilge de-watering system in all compartments.
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 20 August 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 11 May 2004 Resolved
Prove proper operation or renew port side inboard seachest valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2004
Resolved 12 May 2004
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 11 May 2004 Resolved
Renew/ repair propellers and port side propeller key.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2004
Resolved 12 May 2004
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 11 May 2004 Resolved
Prove proper operation of anchor system.
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 20 August 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 11 May 2004 Resolved
Tighten fire extingisher bracket and provide brackets for all fire extingishers on station.
Due 11 May 2004
Resolved 11 May 2004

Casualty record · 3

18 October 2007Routine · role: Involved in a Marine Casualty · activity 3105226
19 July 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6484530
9 January 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6886088
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.