Records from 2007 to 2025. Most recent: inspection, 23 September 2025.
Documentation record
Registered dimensions (L × B × D)115.0 ft × 28.2 ft × 9.4 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)115.0 ft × 28.2 ft × 9.4 ft
ITC tonnagegross 431 / net 129
BuilderISLAND BOATS INC. · JEANERETTE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it431 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
129 - Convention (Subpart B), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
23 September 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8239920
4 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7995860
21 August 2024
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7986341
12 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7807814
23 August 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7540897
27 July 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7516097
22 September 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7318259
12 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7035517
5 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7025168
8 October 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6830120
14 August 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6511514
7 August 2018
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6503222
24 July 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6488396
2 August 2017
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6220227
2 August 2017
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228381
21 March 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6109660
30 November 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6049994
16 August 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5974032
4 August 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5962196
13 October 2015
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5746124
5 August 2014
Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4943557
7 April 2009
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3447099
13 August 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3297196
27 May 2008
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3218543
18 October 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3105226
22 March 2007
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2892963
15 February 2007
Hull Examination · Inclining Experiment · COI Inspection · Initial Construction-Excluding Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2872471
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including...Operation of the fire main system and checking of the pressure at the most remote and highest outlets. Pipe in the tank room leading to the 2nd deck stern fire hose had a leak, posing a risk to adequate fire main pressure if the pipe continues to corrode.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 23 September 2025
Resolution: Pipe was replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 September 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station...A light to indicate discharge. The fixed fire extinguishing system indicator at the operating station was faulty; it incorrectly indicated that the system had discharged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2025
Resolved 25 September 2025
Resolution: Indicator replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 September 2024
Resolved
Whenever damage or deterioration to hull plating or structural assess.. permanent repair.
46 CFR 176.600 (d)
Port and Starboard exhaust frames have cracks and missing welds.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2024
Resolved 21 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023
Resolved
Electrical equipment on a vessel mist be installed and
maintained. Renew door for electrical box at operating
station to allow for closure.
46 CFR 183.700
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Each battery must be... secured to protect against
shifting. Install straps on batter installation.
46 CFR 183.350(b)
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 12 October 2023
Resolved
The construction and arrangement of a vessel must allow
for the safe operation of the vessel. Observed complete
wastage/hole of through-hull fitting for the bilge
manifold discharge allowing for light/water to enter the
port side tank room from exterior.
Renew.46 CFR 177.100
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 25 October 2023
Resolution: Through-hull fitting cropped and renewed, all sat. Pictures in docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
All machinery and equipment must be installed and
maintained in such a manner as to afford adequate
protection from causing fire, explosion, machinery
failure and personnel injury. Sea suction to starboard
generator is leaking. Renew.
46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 12 October 2023
Resolved
An exposed hazard, such as gears or rotating machinery,
must be properly protected by a cover, guard or rail.
Protective guard for engine room ventilation fan
requires replacement.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 25 October 2023
Resolution: Guards replaced over port and starboard ventillation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023
Resolved
The engine head, block, and exhaust manifold must be
water-jacketed and cooled by water from a pump that
operated whenever the engine is in operation. Sea water
suction line is corroded and has broken hose clamps.
Replace to satisfaction of CG MI.
46 CFR 182.420(a)(1)
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023
Resolved
Electrical equipment on a vessel must be installed and
maintained to minimize accidental personnel contact with
energized parts. Loose/exposed wires identified near
HVAC system. Identify origin of wires and secure.
46 CFR 183.200(c)
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 August 2018
Resolved
AIS data showing zero length or beam/zero draft due to missing length of vessel points from AIS ANT location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 January 2019
Construction/Loadline › Hull › Bottom Plating
Issued 5 August 2014
Resolved
Address area of pitting located on port side galley (under cook top) Provide repair proposal if gauging determines the pitting exceeds 25% of original plate thickness.
Action required: 705 - Other - as specified
Resolved 8 August 2014
Resolution: Observed satisfactory cut-out, fit-up, weld, and non-destructive testing on 41x48in and 43x42in aluminium sections of hull bottom plating.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 March 2007
Resolved
Mount PFD placards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2007
Fire Fighting › Fire Pumps › Pressure
Issued 22 March 2007
Resolved
Prove fire pump output at pump is at least 60 PSI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 22 March 2007
Resolved
Provide a BII fire extinguisher in galley.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2007
Documentation › Markings/Placards › Warning Signs
Issued 22 March 2007
Resolved
Mount "May Day" placard at radio station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 22 March 2007
Resolved
Label breakers properly in engine room.
Due 10 April 2007
Resolved 11 April 2007