This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it34224 - Displacement, Metric Ton 27185 - Dead Weight, Metric Ton 15724 - Convention (Subpart B), Gross Ton 7925 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 1 January 2018Resolved
Instrumentation shall be fitted for continuously indicating and permanently recording, when the inert gas is being supplied. PSCO's observed 14 inoperable indicator lights on the inert gas generator control panel which have not yet been rectified since being noted on previous USCG examination, 25OCT2017. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2018
Resolution: Received Class report attesting to proper repairs. Also witnessed IGG control panel working properly.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 25 October 2017Resolved
The arrangements and position of openings in cargo tank deck from which emissions from flamable vapors can occur, shall be such as to minimize the possibility of flammable vapors being admitted or collecting in the vicinity of deck machinery or equipment which may constitute an ignition hazard. Cargo tank hatches missing dogging devices.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 January 2018
Resolution: Reviewed Class Survey Statement as well as observed newly installed dogging devices on cargo tank hatches.
Deck/Cargo › Inert Gas System › Deck Mechanical Non-Return Valve
Issued 25 October 2017Resolved
At least 02 non- return devices shall be fitted in the inert gas supply main in order to prevent the return of hydrocarbon vapor to the machinery space. The valve housing on the double block and bleed actuator is fractured, preventing the valve from operating correctly, posing a danger of flammable vapors migrating back to the machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 January 2018
Resolution: Reviewed Class Survey Statement as well as observed new valve housing installation
Lifesaving › Lifeboat Equipment › Food Ration
Issued 25 October 2017Resolved
Each ship survival craft shall be stowed fully equipped as required by the code: Food rations shall be kept in an airtight packaging and stowed in an airtight container. Vessel's freefall lifeboat contained 09 food rations that were no longer airtight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2017
Resolution: Received a survey statement narrative from the Classification society attesting to the purchase of new lifeboat food rations.
Deck/Cargo › Inert Gas System › Deck Mechanical Non-Return Valve
Issued 25 October 2017Resolved
Each inert gas system must be designed, constructed, and installed in accordance with provisions of 74 Solas (2001) II-2/62.1 with the following provisions (1) acceptable types of water seals include the wet and semi-wet type. OTher types of seals may be accepted on a case by case basis if approval is given by the Coast Guard MArine Safety Center. Vessel unable to provide proof of Marine Safety Center acceptance of the double block and bleed arrangement.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 17 April 2018
Resolution: SEC HOU-GAL PSC received a letter from MSC satisfying the requirement.
Engineering › Lubricating Oil Service System › Cooler
Issued 25 October 2017Resolved
Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ships in all respects will remain fit and proceed to sea without danger to the ship or persons onboard. Vessel's #3SSDG Lube oil/seawater heat exchanger is leaking saltwater.
Action required: 705 - Other - as specified
Due 25 November 2017
Resolved 1 January 2018
Resolution: Reviewed Class Survey Statement as well as observed leak-free seawater heat exchanger.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 25 October 2017Resolved
Inert gas systems shall be operated as to render and maintain the atmosphere of the cargo tank non-flammable at all times. Vessel proved unable to demonstrate proper operation of the system with deficiencies noted as to the pressure regulating valve, oxygen and pressure recording device, various inoperable alarms, and 14 inoperable indicator lights.
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Deficiency was rectified on the spot.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 25 October 2017Resolved
The fire integrity of the bulkheads and decks shall be maintained as surveyed. The insulaton on the A-60 bulkhead in the vestibule between the steering gear and the engine room is damaged.
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Vessel repaired damaged bulkhead with supplies that were on board.
Efficient guard rails or bulwarks shall be fitted on all exposed parts of the freeboard and superstructure side aft quarter main deck railing bars missing. ICLL 66 Reg 25 (2)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 March 2017
Resolved 17 March 2017
Resolution: Recieved class report satisfying the deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 26 August 2016Resolved
Alarm system shall be provided for all important pressure, temperatures and fluid level and other essential parameters. The High Temp Water Outlet Temp Alarm on the ships auxiliary generators frailer to activate at the required temperature. SOLAS (2001 Cons) II-I/ 53.4.3 17(a)
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 26 August 2016
Resolution: Class issued a Condition, allowing the vessel to sail, but the engineers must continuously monitor the jacket water temps. util 9/9/16
The company should establish procedures, including checklist for key shipboard operation. The departure checklist does not include all required procedures. 74 SOLAS(09 CONS) IX-1/3.1 ISM Part A 7 Request audit from RO
Action required: 705 - Other - as specified
Due 4 September 2016
Resolved 16 September 2016
Resolution: The company and vessel updated their prior to departure procedures.
The company should clearly define and document the masters responsibility with regard to verifying that specified requirements are observed. Master did not give engineering adequate amount of time to follow checklist, prior to departure. 74 SOLAS (09 CONS) IX/ 3.1 ISM Part A5.1.4 Request Audit from RO
Action required: 705 - Other - as specified
Due 4 September 2016
Resolved 16 September 2016
Resolution: The Company and Vessel update their procedures, to ensure the ER has the amount of time needed to follow checklist.
The company should clearly define and document the masters responsibility with regard to verifying the specified requirements are observed. Master did not ensure STCW Requirements have been met due to hours of rest log, not depicting a true picture of crews rest, on 25AUG16. 74 SOLAS(09 Cons) IX/3.1 ISM Part A 5.1.4 Request audit from RO
Action required: 705 - Other - as specified
Due 4 September 2016
Resolved 16 September 2016
Resolution: Class has signed off on the vessel's following the proper amount of rest/ work. Cites, the violation was due to a lack of proper planning during unforeseen circumstances.
Oil filtering equipment shall indicate when 15ppm can not be maintained. The ODM is running in a fault mode. Can not read 0. MARPOL 2011 Ann.1 reg 14.7 15a
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2016
Resolved 26 August 2016
Resolution: Class was on board when the new sensor arrived and cleared the deficiency
Lifesaving › Lifefloat › Serviceable
Issued 25 August 2016Resolved
Every lifeboat shall be made for ahead and astern propulsion. The gear box needed to be replaced. SOLAS 14 Ch.3 Reg 34 LSA Ch.IV Reg. 4.4.6.5 10abc
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Resolution: The vessel had ordered a replacement gearbox. A Tech was there to install it and properly tested it for Class, Flag rep and Coast Guard inspectors to witness.