Inspection history · 27
31 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8338696
26 September 2025
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8242122
5 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8202820
16 May 2024
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7913456
25 January 2024
Drydock Exam · In-Service Inspection · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7855669
5 January 2024
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7845530
5 January 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7848506
23 August 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7776565
12 May 2023
MARPOL Annex VI Survey · COI Inspection · MARPOL Annex I Examination · In-Service Inspection · MARPOL Annex IV Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7674776
21 January 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7636700
8 December 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7573089
6 January 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329240
25 June 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7238131
24 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7169871
5 January 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7118267
1 July 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7044697
5 February 2020
Damage Survey · Examination of Repairs · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6902870
16 October 2019
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6825105
25 June 2019
Deficiency Check · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6713376
17 October 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6555226
5 January 2018
Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333235
19 October 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6261858
16 October 2017
Administrative Inspection · Deficiency Check · Inclining Experiment
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6291295
7 September 2017
Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6261346
26 October 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5999213
23 May 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5845405
22 February 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5819779
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 June 2024
Resolved
No means shall be provided for locking doors giving access to either of the two required means of escape, except that crash doors or locking devices, capable of being easily forced in an emergency, may be employed provided a permanent and conspicuous notice to this effect is attached to both sides of the door.
MI observed the engine room aft means of escape secured with a chain and latch pin. Provide plan/checklist that reflects ensuring this door is not latched or pinned prior to getting underway to MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024
Resolved
Each cable installation must meet Sections 6, of IEEE 45.8-2016 (incorporated by reference; see § 110.10-1 of this subchapter). MI observed several cables along the overhead of the aft engine room in way of the port main engine that were not supported properly by hangers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 17 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024
Resolved
Ground indicators must be at the vessel's ship's service generator distribution switchboard for the normal power, normal lighting, and emergency lighting systems.
MI observed the port generator “A” phase ground detection light extinguished. Ensure proper operation the “A” phase light to the satisfaction of USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 17 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 June 2024
Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards.
MI observed 2 bench grinders with no guards installed. Install guards or remove bench grinders to the satisfaction of USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2024
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 June 2024
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date.
The information on the EPIRB registration is incorrect and must be updated to reflect the proper vessel type and total number of persons it can carry, i.e. change 200 persons to 20 persons.
47 CFR 80.1061(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 20 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2024
Resolved
A survey, either general or partial, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its equipment, or whenever any important repairs or renewals are made. The survey shall insure that the necessary repairs been effectively made.
Vessel's port propeller shaft was slipping out of it's coupling causing flooding within vessel. Identify and conduct repairs to the satisfaction of the attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2024
Resolution: Vessel conducted satisfactory repairs. The repairs were inspected and the shaft was operationally tested, all satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 5 January 2021
Resolved
Each pump must be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approximately 50 psi. The vessel's fire pump discharge pressure is 44 psi in the E/R. Vessel must prove proper operation of the fire pump by the end the vessel's next dry dock date to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2021
Resolved 25 June 2021
Resolution: Witnessed satisfactory operation and pressure of the vessel's fire pump.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 January 2021
Resolved
All firehose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 psi. The firehoses onboard could not be tested to 100 psi. Prove satisfactory firehose test at minimum 100 psi.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 29 January 2021
Resolution: Firehoses tested at 250 psi.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 January 2021
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: Every power driven vessel of 20 meters or over in length while navigating. Vessel does not have a Bridge-to-Bridge certificate. Obtain valid Bridge-to-Bridge Certificate. 47 CFR 80.1001.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 29 January 2021
Resolution: Vessel has valid Bridge to Bridge Certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2019
Resolved
All fire hoses must be subject to a test pressure equivalent to the maximum pressure to which they may be subjected to in service, but not less than 100psi.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 17 October 2019
Resolution: Received records of testing by Breakwater International.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 October 2019
Resolved
Each immersion suit must have a lifejacket light. Three immersion suits on bridge had expired lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 17 October 2019
Resolution: Received invoice of purchase and pictures of proper installations.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 October 2019
Resolved
Each circuit breaker must meet the general provisions of article 240 of NFPA 70. 14awg cable 15amp max, 12awg 20amp max, etc. The following breakers are to remain open until conductors are properly protected: Bridge panel – Breakers #9, #13, and #24. Galley Panel: Breakers #3, #4, #5, #6, #10, and #17. Engine Room Panel: Breakers #6, #7, #9, #12, #22, #24 and #26.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 17 October 2019
Resolution: Received invoice of purchase and pictures of proper installations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 October 2019
Resolved
After any survey of the vessel no change shall be in vessel’s structure, material or scantlings without approval. MCT (Roxtec) between tunnels has 02 blocks that need replaced in accordance with type approval.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 17 October 2019
Resolution: Received invoice of purchase and pictures of proper installations.
Engineering › Bilge Water Management System › Valve
Issued 19 October 2017
Resolved
provide and prove proper operation of 04 stop/check bilge zone suction valves.
Action required: 705 - Other - as specified
Due 20 November 2017
Resolved 15 November 2017
Resolution: 2" check valves installed below bilge stop valves. System operations tested, all sat.
Stability › Incline Test › General
Issued 16 October 2017
Resolved
Provide a list of all weight changes since 2012 stability test.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 29 August 2018
Resolution: USCG received approved T&S booklet by ABS under NVIC 3-97.
Stability › Incline Test › General
Issued 16 October 2017
Resolved
Provide approved stability letter from appropriate stability test if wirght changes exceed thresholds identified in Marine technical Note 04-95, Lightship Change Determination: Weight-Momment Calculations vs. Deadwieght Survey vs. Full Stability Test.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 29 August 2018
Resolution: USCG received approved T&S booklet by ABS under NVIC 3-97.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 26 October 2016
Resolved
Prove proper operation of engine room fire detection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2016
Resolution: All fire detection equipment is operational.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 October 2016
Resolved
Label all reachrod remote shutdwons
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: All reachrod remote sutdowns properly labled.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 26 October 2016
Resolved
Prove proper operation of all temp/pressure alarms/shutdowns, & overspeeds on mains and generators.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 3 November 2016
Resolution: Observed proper operation of designed shut down/ alarms for both mains and generators. All sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 26 October 2016
Resolved
Remove camera cables from passageway to engine room MCT. Only 1 cable allowed per block.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: camera cables removed and properly sealed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 October 2016
Resolved
Replace grab line on stbd side ring bouy.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: Grab line on stbd side ring bouy replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 October 2016
Resolved
Properly secure float light line to ring bouy port and stbd brige.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: float lights properly secured to ring bouys.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 October 2016
Resolved
Replace batteries in all ring life bouy float lights.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: Replaced all batteries in ring life bouys float lights.
Fire Fighting › Fire Hydrants › Condition
Issued 26 October 2016
Resolved
Repair or replace valve handel on fire monitor.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: Replaced valve handle on fire monitor.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 October 2016
Resolved
Properly secure stern light for proper arc of visibility.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 31 October 2016
Resolution: Stern light properly mounted.