Inspection history · 49
1 June 2026
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8384534
1 December 2025
COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8262416
2 June 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8146943
1 May 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8126470
2 December 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8040504
24 June 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7938494
3 May 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7905823
4 December 2023
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7832143
4 December 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7849742
24 July 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7750815
9 June 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7709379
10 April 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7665779
9 December 2022
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7605871
2 November 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7587951
9 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7574244
6 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572630
6 June 2022
PSC B · COC-CVE Quarterly · Deficiency Check · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7469604
9 March 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7408556
9 December 2021
PSC A · Administrative Inspection · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7358361
6 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6936060
2 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6934727
22 February 2020
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6914273
14 December 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6873841
7 December 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6869183
15 October 2019
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6834167
5 September 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6804546
13 April 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6658430
10 March 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6638791
10 February 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6622983
8 December 2018
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6600784
27 October 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6569054
13 October 2018
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559593
10 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6558418
15 June 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6445234
7 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6442177
8 April 2018
ISPS III Exam · Deficiency Check · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6387762
22 October 2017
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6290731
12 August 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6240446
12 July 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6206767
16 June 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6177890
25 May 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6155127
20 April 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6128938
9 March 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6105835
26 February 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6099674
29 January 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6079675
9 November 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6038129
23 October 2016
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6027105
8 May 2016
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5871723
21 April 2016
Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5859415
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs observed 02 pipe leaks: 01 hot water pipe leak in Room 1021 and freshwater pipe leak behind FSD 3.006.
74 SOLAS (20) I/Reg. 11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 19 June 2025
Resolution: Received Class Survey Report attesting that corroded parts of pipes were renewed by crew inside of passenger cabin 1021 and inside of store room (FSD 3.006), leakages were eliminated and inspected by DNV surveyor with satisfactory result.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 June 2025
Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO's observed lifeboat #7 starboard side main steering arrangement not operating.
74 SOLAS 20 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 December 2024
Resolved
All ifesaving appliances and arrangements shall comply with the applicable requirements of the Code. LSA states the container shall be marked with multiple items such as serial number for example. PSCOs observed on port forward liferaft station that the container was not marked with all proper items such as serial number.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 2 December 2024
Resolved 2 December 2024
Resolution: Used p-touch and liferaft service cert to replace required marking.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 December 2024
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevent catagory having the most stringent boundary requirements. PSCOs observed cardboard and wood being stored in an electrical locker. FSD.0.067
Action required: 10 - Deficiency Rectified
Due 2 December 2024
Resolved 2 December 2024
Resolution: Removed materials from electrical locker.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 June 2024
Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Emergency powered lights for starboard side embarkation areas over lifeboats 5, 7, and 9 are non-operational.
74 SOLAS (20) III/16.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
Resolution: Vessel electrician conducted repairs and showed PSCO working emergency lights before exam was completed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 June 2024
Resolved
All "A" class doors located on stairways, public spaces and main vertical zone bulkheads in escape routes shall be equipped with a self-closing hose port of material, construction and fire resistance which is equivalent to the door into which is fitted... FSD 2956 was wedged open and not self closing.
74 SOLAS(01) II-2/30.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 June 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 June 2024
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. Deck 10 forward passenger stairwell had a laundry bin blocking safe means of escape.
74 SOLAS (01) II-2/28.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2023
Resolved
Vessel with voyage time less than 96 hours must submit a NOA before departure but at least 24 hours before arriving at port. Vessel submitted a notice of arrival at approximately 1918 on July 23rd, 2023 and arrived at the Port of Miami, FL on July 24th, 2023 at or around 0628.
33CFR160.212(a)(4)(II)
Action required: 10 - Deficiency Rectified
Resolved 24 July 2023
Resolution: Vessel was notified of proper reporting requirements for eNOA. Including phone or fax.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 June 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The onboard davit break release cable was broken and did not operate as intended on lifeboats 12, 18, and 22.
74 SOLAS 20 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 June 2022
Resolution: Vessel submitted LR report attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 December 2019
Resolved
The condition of the ship and its condition shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons on board. The grey water pipe that passes through the aft peak ballast tank has a hole and is leaking grey water into the tank.
74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2019
Resolved 28 December 2019
Resolution: All grey water pipes repaired.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 October 2018
Resolved
0299 - Other (crew)- Every crew member shall be given instructions which shall include but not necessarily be limited to the operation and use of the ships inflatable liferafts and operation and use of fire extinguishing appliances. Vessels liferaft crews were unfamiliar with the procedures to secure, level and safely embark liferaft. Additionally, stairwell guides did not have knowledge of fire extinguishing appliances in the stairwell.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2018
Resolved 27 October 2018
Resolution: Vessel provided extra training to the satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 13 October 2018
Resolved
0999 - Other (Safety in General) - In ships carrying more than 36 passangers the hull, superstructure and deckhouse shall be subdivided into main vertical zones by "A-60" class divisions. MVZ2 Deck 0 had missing lagging above door F.S.D 0.080 compromising A-60 boundary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2018
Resolved 27 October 2018
Resolution: Vessel installed A class insulation in required areas to the satisfaction of class
Fire Fighting › Means of Escape › Emergency Lighting
Issued 8 April 2018
Resolved
0350- Means of escape - Means of Escape shall be marked by lighting or photoluminescent strip indicators placed not more than .3 m above the deck. Photoluminescent tape located throughout deck 0 is missing and in need of repair along evacuation routes. - SOLAS (01) II-2/28.1.10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2018
Resolved 25 April 2018
Resolution: Received class survey report attesting to the correction of missing photoluminescent tape throughout deck 0.
Personnel › Training › Fire Fighting Basic
Issued 8 April 2018
Resolved
0750-Personnel Training- Crew Members shall be trained to be familiar with the arrangement of the ship as well as the location and operation of any fire fighting systems and appliances that they may be called upon to use. Numerous crew members found to be unfamiliar with fire fighting appliances on board. - SOLAS (14) II-2/15.2.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2018
Resolved 25 April 2018
Resolution: Received class survey report attesting to the correction of crew member knowledge through training on fire fighting appliances and systems.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 April 2018
Resolved
-0750- A Class Division Penetration- A class divisions are those divisions that shall be constructed of steel and constructed as to be capable of preventing the passage of smoke and flame to the end of the one hour standard fire test. A-Class bulkhead surrounding emergency generator is severly wasted. SOLAS (01) II-2/3.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2018
Resolved 16 June 2018
Resolution: Wasted area was cropped and renewed. Reveiwed class approval and visually inspected the repair.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 October 2017
Resolved
1730 - Any ship of 10k GT and above shall be fitted with oil filtering equipment. As of short term IOPP the ship is required to have 01 operational oil filtering equipment, the vessel oil filtering equipment is not fully operational. MARPOL Annex I Reg. 14.2
Due 22 October 2017
Resolved 22 October 2017
Resolution: Technicians and class demonstrated proper operation of Oil Filtering Equipment.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 May 2017
Resolved
Oil filtering equipment shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15PPM. Vessel Primary oily water seperator's recirculation 3 way valve does not receive the signal to change posistions when the oil content reaches 15 PPM. 16ac
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 6 June 2017
Resolution: Received completed survey report from [name withheld] stating that the Westfailia No 1 Port Side OWS control panel and all connections restored. The OWS was tested under working conditions to the surveyor satisfaction.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 23 October 2016
Resolved
0220 - Certificates of competency - Documentary proof shall be readily available that application for endorsement has been submitted to the Administration. Proof of application for endorsement for several licensed officers was not available. 78 STCW (11 Cons.)Reg. I/10
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 October 2016
Resolution: Copies of crew application for endorsement from flag state submitted by the company. See attached documents.