Records from 2009 to 2025. Most recent: inspection, 21 July 2025.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 July 2025
Resolved
STBD side ladder has a broken locking device and needs to be repaired/replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2025
Resolved 23 July 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 April 2024
Resolved
None of the starboard side and one on port side aft bilge high water alarms and bilge pumps were working. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 April 2024
Resolved
One fire bucket had a large crack. Must replace fire bucket with lanyard so you have a total of 3 on board prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2023
Resolved
Steering system has issues and unable to steer both outboards in sync. Must make repairs and conduct test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 April 2023
Resolved
Unable to get vessel underway for drills due to steering issues. Once steering system is repaired, must conduct drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 April 2023
Resolved
Life floats retro reflective tape was found worn/faded. Both life floats needs retro reflective tape replaced with SOLAS approved retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 29 May 2023
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 1 August 2022
Resolved
Several cracks through out the deck were found, STBD side stern has a crack about 2 feet long that is separated from the transom making compartment non watertight. Must make repairs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2022
Resolution: Completed drydock inspection/repairs
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2022
Resolved
3 adult life jackets needs replacing and 5 adult life jackets needs repairs. Total passenger count on board reduced to 45 total.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 19 November 2022
Resolution: 8 new life jackets were placed onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 1 August 2022
Resolved
Life jacket storage boxes/passenger seating need to be secured to deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 19 November 2022
Resolution: Storage boxes were through bolted to deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2022
Resolved
Life ring grab line is dry rotted and braking apart. Must replace grab line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 28 November 2022
Resolution: New anchor on board
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 August 2022
Resolved
Both life floats are "black" from mildew. Must clean both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 19 November 2022
Resolution: Two new life floats were placed onboard vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 1 August 2022
Resolved
Anchor is rusted and some areas are wasted more than 25 percent. Must make repairs or replace anchor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2022
Resolved 28 November 2022
Resolution: new line attached to life ring
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 12 August 2020
Resolved
Renew exterior seal on the viewing panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2020
Resolution: Vessel rep cleaned old sealant around viewing panel and installed new 5200.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 August 2020
Resolved
Make watertight the penetrations in the vessel's stern that are used for running the outboard engine controls prior to credit hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2020
Resolution: Vessel rep installed a new watertight coupling for the port and starboard engine controls to pass through the transom.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2020
Resolved
Install 02 new life floats in a float-free manner and attach them to the vessel with a float-free link and painter. Prior to operating beyond 03 miles from shore.
Action required: 705 - Other - as specified
Resolved 29 July 2020
Resolution: Life floats installed to vessel with float-free link and painter.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 July 2020
Resolved
Make masthead light operational so vessel is in compliance with applicable navigation rules.
Action required: 10 - Deficiency Rectified
Resolved 23 July 2020
Resolution: Vessel rep replaced fuse for masthead light.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 July 2020
Resolved
Provide updated copy of Coast Guard Light List for operational area.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2020
Resolution: Vessel provided 2020 Coast Guard Light List.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2020
Resolved
Make the starboard side forward submersible electric bilge pump operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2020
Resolution: Submersible electric bilge pump is operational.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 July 2020
Resolved
Make the port bilge high level alarm operational with a visual and audible alarm at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2020
Resolution: High level alarm is operational with a visual and audible indicator at the operating station.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 July 2020
Resolved
Conduct test of the main steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2020
Resolution: Conducted satisfactory sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2020
Resolved
Conduct test of propulsion engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2020
Resolution: Conducted satisfactory sea trials
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2020
Resolved
Remove dead end wiring from under the steering console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 July 2020
Resolution: Dead end wiring removed from under steering console.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2019
Resolved
Bilge pumps must have a UL approval. Current Bilge pumps (Rule 1500) are not UL approved. Pumps must be permanently mounted, one pump was not secured. None of the pumps had grounding wires attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 26 August 2019
Resolution: New UL Rule 2000gph pumps installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2019
Resolved
Fuel tanks must be be electrical bonded to a common ground. There was no grounding wire present on either fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 19 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 July 2019
Resolved
Life floats must have the approval label, vessel name, and max passengers visible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 23 July 2019
Resolution: relabled the floats and identified the label.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 July 2019
Resolved
Coast Pilot and Light List must be current and up to date. Both were out dated. Charts must be of large enough scale to make safe navigation possible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 19 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 October 2018
Resolved
Raw water inlet for MSD seized in the open position. Replace shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Valve was renewed/repaired, tested all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 October 2018
Resolved
Repair/replace all positive shutoff valves for bilge pump hoses at the hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: All bilge pump valves were renewed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 18 October 2018
Resolved
Repair FRP tabbing on STBD side deck beam just below ladder on outboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Deck beam tabbing was repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 October 2018
Resolved
Repair FRP on both Port and STBD transom knees on internal side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Both port and stbd transom knees were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 October 2018
Resolved
STBD transom engine mount bolts (bottom 2) need to be replaced/rebedded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Hardware on both transom platform/engine mounts have been renewed.
Fire Fighting › Fire Bucket › Capacity
Issued 23 April 2018
Resolved
Vessel required to have 2.5 gallon firebuckets instead of 5 gallon
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 22 May 2018
Resolution: New fire buckets onboard
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 23 April 2018
Resolved
Inadequate retro reflective tape on 20 lifejackets, required to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 22 May 2018
Resolution: New tape added
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 October 2016
Resolved
Provide indicators for all automatic bilge pumps.
Action required: 705 - Other - as specified
Due 24 November 2016
Resolved 20 December 2016
Lifesaving › Lifebuoys › Serviceable
Issued 24 October 2016
Resolved
Repair/replace life rings due to hole
Action required: 705 - Other - as specified
Due 24 November 2016
Resolved 3 November 2016
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 24 October 2016
Resolved
Electrically bond fuel tanks to common ground
Action required: 705 - Other - as specified
Due 26 November 2016
Resolved 20 December 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 24 October 2016
Resolved
Provide waste management vessel
Action required: 705 - Other - as specified
Due 24 November 2016
Resolved 3 November 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 October 2016
Resolved
Provide complete first aid kit
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 3 November 2016