Records from 2009 to 2026. Most recent: inspection, 23 February 2026.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS FL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Net Ton
9 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
23 February 2026
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8305728
15 May 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8136827
26 March 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8105072
22 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7899256
17 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7668503
1 March 2023
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7643687
19 May 2022
Examination of Repairs · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7453867
19 February 2021
Internal Structural Exam · Deficiency Check · Examination of Repairs · COI Inspection · Administrative Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7142929
11 June 2020
Internal Structural Exam · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6974698
17 May 2019
Annual Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6688865
1 February 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6618492
24 May 2018
In-Service Inspection · Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661126
26 December 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6334263
23 January 2017
Internal Structural Exam · Hull Examination · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6108086
3 May 2016
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 5878920
17 February 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5816934
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 February 2026
Resolved
New life ring is need on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 February 2026
Resolved
Replace missing barrel bolt on PORT side ladder.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 February 2026
Resolved
Replace worn life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2025
Resolved
Provide a forward masthead light prior to operating in periods of reduced visibility.
Action required: 705 - Other - as specified
Resolved 15 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2025
Resolved
Attach the painter to each life float and properly stow it to allow the survival craft to float free and engage the float-free link prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 15 May 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 April 2024
Resolved
Hydrostatic release expired in 2023. Must install new hydrostatic release and mark to expire in two years from date of install.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 23 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
Both life floats were almost completely black on top from the sun. Must clean and or repaint both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 23 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2024
Resolved
Starboard side aft auto bilge pump would turn on, but the visual indicator at the operating station was not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2024
Resolved 23 April 2024
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 April 2023
Resolved
Bilge high water alarm switch on operating station was not working properly. Only the visual indicator was working, not the audioable indicator. Replace switch and test to the satisfaction of attending CG Marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 17 April 2023
Resolution: New switch was installed and tested before end of day.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2023
Resolved
Failed to conduct drydock and internal structural inspection before due date. Vessel must conduct a drydock and internal structural inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2023
Resolution: Conducted drydock and internal structural inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2022
Resolved
Port outboard engine unable to start due to needing repairs. Must conduct repairs and satisfactory sea trials prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2022
Resolution: Rebuilt power head, conducted satisfactory sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022
Resolved
STBD life float needs repainting and labeling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 17 March 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2021
Resolved
COI expired 17 FEB 2021. Vessel must conduct a new COI inspection prior to carrying passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2021
Resolved 24 February 2021
Resolution: Conducted COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2021
Resolved
Both life floats have heavy black mold all over. Some areas are fadded. Must clean and repaint both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 19 March 2021
Resolution: Owner/ Operator recently purchased 2 new lifefloats, replacing previously inspected. Confirmed both lifefloats contain both vessel's name and passenger count.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 February 2021
Resolved
Vessel has automatic bilge pumps and no visual indicators at the operating station to alert when bilge pumps are running. Must install visual indicators at the helm station for each bilge pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 22 March 2021
Resolution: Four visual indicators were installed at the helm, one light per pump. Visually inspected and confirmed operational function of each bilge light.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 June 2020
Resolved
Port fuel tank vent is missing the flame screen. Provide new screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2020
Resolution: New screen was installed in the Fuel tank vent pipe.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 24 May 2018
Resolved
All bilge pump hoses are wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Renewed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 May 2018
Resolved
Port hull audible bilge alarm is too weak to hear, renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 May 2018
Resolved
Renew reflective material on all PFD that have 25% or more loss of cells.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Renewed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2018
Resolved
Batteries are not mounted and do not have covers. Mount batteries, and provide covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Batteries mounted, and covers provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 May 2018
Resolved
Needs to provide VHF that has GPS and MMSI input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Provided
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 3 March 2017
Resolved
Fuel tank vent is missing flame screen
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 20 March 2017
Resolution: Flame screen was installed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 March 2017
Resolved
Compass light is extinguished. Renew/repair.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 20 March 2017
Resolution: New Compass was installed.