MAURY USCG vessel records Sign in
← All vessels

KEYS DIVER

KEYS DIVER is a 1987 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1989, most recently in March 2025, along with 43 deficiencies — 5 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2006 and 2019.

Records from 1989 to 2025. Most recent: inspection, 27 March 2025.

Built
1987
Last inspected
27 March 2025
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAP6567
282145
Flag
UNITED STATES
366665460, 368123550
Maury page id
psix-282145

Inspections, by type

…with no type recorded7
…past their stated due date4
Years with a record 30 calendar years (1989–2025)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.6 ft × 14.3 ft × 8.0 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBETHLEHEM FAB INC · BOWLING GREEN, FL, UNITED STATES · built 1987
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Net Ton
30 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL3634MMSI 368123550 · active · compulsorily equipped · granted 10 December 2019, expires 10 December 2029
WDI9961MMSI 366665460 · active · compulsorily equipped · granted 8 September 2016, expires 8 September 2026
WAP6567MMSI 366665460 · expired · compulsorily equipped · granted 10 September 2005, cancelled 16 January 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENCOUNTER Passenger (Inspected) · MISLE 786325 · 1 March 2019 · activity 6710868DOLPHIN Passenger (Inspected) · MISLE 449765 · 26 December 2017 · activity 6334263FL4341NG Passenger (Uninspected) · MISLE 875122 · 26 October 2006 · activity 2811471

Inspection history · 50

27 March 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8100496
22 October 2021 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7337815
22 September 2020 COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7062789
21 November 2019 Administrative Inspection · Hull Examination · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6860518
1 March 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6710868
18 December 2018 Administrative Inspection · Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6601334
26 December 2017 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6334263
8 December 2017 Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6558724
29 November 2017 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6538046
3 October 2017 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293548
8 September 2016 Deficiency Check · Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5998554
29 February 2016 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5842846
24 September 2015 Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5726883
13 December 2011 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4212098
13 September 2010 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3848819
24 September 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3331531
27 April 2008 Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 3193321
26 November 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3104248
24 September 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3064877
26 October 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2811471
25 September 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2784592
12 September 2005 COI Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2490258
6 October 2004 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2207094
10 October 2003 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1922901
23 September 2003 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1907896
16 October 2002 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1688571
15 October 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1412374
26 September 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426668
2 October 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1444415
16 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 812572
8 November 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393269
13 September 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1463517
26 October 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457607
9 October 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1109633
9 September 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 786039
29 October 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164266
5 December 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183590
27 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880750
16 October 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879561
11 September 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 873585
12 October 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1177927
19 October 1993 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838124
2 March 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839287
30 October 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 826218
15 October 1991 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938146
19 September 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1214994
7 September 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911582
27 April 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1346629
14 March 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1207414
3 March 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1032672

Deficiency record · 43

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2021 No resolution recorded
Vessel failed to have its 2 yr drydock inspection. Must conduct drydock inspection and complete and repairs prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 October 2021 No resolution recorded
MDE dropped a valve and engine needs rebuilt. After rebuild or repower, must conduct engine alarm testing and sea trials prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 24 September 2020 Resolved
50% of crew must be current in CPR. Vessel is not allowed to carry passengers until proof of current CPR. NVIC 1-91
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2020
Resolved 25 September 2020
Resolution: picture was texted to duty phone with Captain and deckhand current CPR card
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 September 2020 No resolution recorded
Old paper chart from 2009 with no updates and torn onboard and GPS last revsion was 2017. Provide new approved paper chart or update electronic chart on GPS. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 September 2020 No resolution recorded
Sea painter line on life float is dry rotted. Replace sea painter line with new correct line. 46 CFR 180.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 24 September 2020 No resolution recorded
Provide proof that the annual MIS report was submitted to the Coast Guard for calendar yr 2019. 46 CFR 16
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 24 September 2020 Resolved
Provide updated crews list and proof of each crew memeber is enrolled in DAPI. 46 Cfr 16
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 25 September 2020
Resolution: Updated copy of crews list was texted to duty phone. All SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2020 Resolved
Captain is only logging Drills as completed. Must log drills with Date, and general description of the drill scenario and training topics. 46 CFR 185.520 & 46 CFR 185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 25 September 2020
Resolution: Instructed both to owner and Captain on how to properly log drills and training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2020 Resolved
Crew training is not being logged. Crew training for new hire's and at least once every month must be logged with date and general description of the training topic. 46 CFR 185.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2020
Resolved 25 September 2020
Resolution: Explained to Owner and Captain both on how and when to log crew training
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2019 Resolved
Renew hose clamps on starboard exhaust muffler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 January 2020
Resolution: Renewed hose clamp with proper clamps and satisfactory test was run.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 December 2019 Resolved
Stern, mast head and anchor lights are extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: Bulb in stern mast head light was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 December 2019 Resolved
Mark life floats with passenger capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: Both life floats were properly marked with passenger capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 December 2019 Resolved
Life ring is missing reflective tape and clip for storage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: Reflective tape and clip were replaced on life ring.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2019 Resolved
First aid kit must be in a sealable water tight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: New first aid kit was purchased and replaced on the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 December 2019 Resolved
VHF must be linked to GPS or have built in GPS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: New VHS radio was purchased with internal GPS integrated.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 December 2019 Resolved
Remote shutoff valves are not marked. Mark per CFR.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: Remote shutoff valves were marked per CFR in a satisfactory location.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2019 Resolved
Renew fire extinguisher brackets and provide 3rd extinguisher in lower cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 January 2020
Resolution: New fire extinguisher brackets were installed and a new 40B:C extinguisher was purchased and put into service.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 December 2019 Resolved
Permanently attach EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2020
Resolution: EPIRB bracket was permanently attached.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 December 2018 Resolved
EPIRB battery is expired. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 18 December 2018 Resolved
Bilge high level visual alarm is inoperable. Repair/Replace
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 December 2018 Resolved
Anchor light is expired. Repair/Replace
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 December 2018 Resolved
Foam life float has rotten straps. Repair/Replace
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 December 2018 Resolved
Provide FCC Station license.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 December 2018 Resolved
VHF must be linked to GPS, and have MMSI# input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2018 Resolved
Bilge pump automatic operation mucst have a light at operation station to notify when pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2019
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 September 2016 Resolved
Retro wasted and missing from several life jackets.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 27 September 2016
Resolution: New retro was installed, and sat.
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 September 2016 Resolved
Life float is missing some of its retro.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 27 September 2016
Resolution: Life Float was repainted and new retro was installed all sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 September 2016 Resolved
Compass light is extinguished.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 27 September 2016
Resolution: Compass light was changed and tested all sat.
Engineering › Bilge Water Management System › Interface Detector
Issued 8 September 2016 Resolved
Bilge visual alarm is inop.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 27 September 2016
Resolution: New bilge alarm was installed and tested all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 September 2016 Resolved
Batteries in float light are extinguished.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 8 September 2016
Resolution: New batteries were installed and tested all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 17 September 2010 Resolved
Update chart and sign, keep charts up to date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2010
Resolution: New chart on board. All sat.
Communications › Radio Communications › EPIRB
Issued 17 September 2010 Resolved
EPIRB registration out of date renew as soon as possible. Vessel restricted to 3 nm from shore until complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2010
Resolved 24 September 2010
Resolution: EPIRB registration complete. All sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 September 2010 Resolved
Small Lifefloat water light needs new batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2010
Resolved 24 September 2010
Resolution: New batteries installed in all float lights. All sat.
Communications › Radio Communications › EPIRB
Issued 17 September 2010 Resolved
EPIRB hydrostatic release is out of date, install new hydrostatic release. Vessel restricted to no more than 3 nm from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2010
Resolved 24 September 2010
Resolution: New hydrostatic release installed. All sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 September 2010 Resolved
Guards for both MDE belts and pulleys are missing. Provide proper guards for MDE's
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2010
Resolved 24 September 2010
Resolution: New guards fabricated for both MDE''s. All sat.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 17 September 2010 Resolved
Freshwater cooling pump on port MDE leaking excessively. Repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2010
Resolution: New pump installed, tested with no leaks. All sat.
Communications › Radio Communications › EPIRB
Issued 10 October 2003 Resolved
Renew hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 13 October 2003
Resolution: Cleared. Received fax receipt indicating a new hydrostatic release was purchased.
Lifesaving
Issued 2 October 2000 Resolved
Replace the hydrostatic release and re-register the EPIRB with NOAA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 October 2000
Resolved 26 October 2000
Lifesaving
Issued 2 October 2000 Resolved
Affix new retro-reflective tape and replace 1 paddle on the L/Fs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 October 2000
Resolved 26 October 2000
Documentation
Issued 8 November 1999 Resolved
Provide a proper current drug testing program as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Lifesaving
Issued 16 October 1995 Resolved
Attach a water light to the ring lifebuoy being used as primary lifesaving equipment. Also, attach the ring lifebuoy to the lifefloats as discussed with inspector.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Accommodation/Occupational Safety
Issued 16 October 1995 Resolved
Replace broken plexiglass window in way of main cabin forward.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Documentation
Issued 3 March 1989 Resolved
PROVIDED LICENSED OPERATOR. (COPY OF OPERATOR'S LICENSE TO BE FORWARDED TO THIS OFFICE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989

Casualty record · 3

26 October 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2811471
29 February 2016Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 dead · activity 5842846
1 March 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6710868
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.