MAURY USCG vessel records
← All vessels

MAP 602

MAP 602 is a 2003 tank barge. The Coast Guard has recorded 34 inspections since 2003, most recently in September 2021, along with 7 deficiencies.

Records from 2003 to 2021. Most recent: inspection, 22 September 2021.

Built
2003
Last inspected
22 September 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 22 September 2021
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 18 calendar years (2003–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

607012
Flag
UNITED STATES
Maury page id
psix-607012

Documentation record

Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 34

22 September 2021 Internal Structural Exam · Drydock Exam · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7316631
14 December 2020 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7111682
22 November 2019 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6870932
27 December 2018 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6603128
14 December 2017 Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6324523
7 December 2017 Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6322512
19 October 2017 COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6290956
5 April 2017 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6118382
26 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5862638
16 December 2015 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5783492
9 March 2015 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5081059
19 December 2014 MTSA Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5038719
27 January 2014 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4789659
11 January 2012 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4226315
11 January 2012 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4237786
16 December 2011 Examination of Repairs · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4209530
11 January 2010 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3662198
17 March 2009 Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3435033
9 December 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3376844
7 March 2008 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3162384
9 January 2007 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2852932
27 September 2006 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2788262
28 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2762039
11 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2621984
14 March 2006 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2602506
6 January 2006 Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2562175
5 August 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2452172
28 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2321497
18 March 2005 MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2320327
14 January 2005 Annual Inspection · MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2274985
10 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238831
20 February 2004 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2009905
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1984539
20 March 2003 Hull Examination · Cargo Tank Internal · Initial Construction-Excluding Oversight · Initial Certification · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1749158

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 December 2020 Resolved
Each cargo tank of a tank barge must have the means to check the liquid overfill protection arrangements at the tank for proper operation prior to each loading. During the inspection, the portable alarm system indicated an incorrect alarming sequence due possibly to an improper installation. Verify and/or correct prior to conducting cargo loading operations. 46 CFR 39.20-9(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2020
Resolution: The alarms have been fixed and are working properly on the MAP 602. Submitted by Chris Stafford
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 November 2019 Resolved
The emergency stop for the pump engine failed to shut the engine down.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 22 November 2019
Resolution: Fixed cabling and engine shit down as intended.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 November 2019 Resolved
Port #1 void hatch lid had a broken hinge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 10 December 2019
Resolution: Replaced lid
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 12 December 2014 Resolved
Slop Tank gauging system inoperable. Needs to be repaired or replaced.
Action required: 705 - Other - as specified
Due 19 January 2015
Resolved 9 January 2015
Resolution: Replace with new gauge stick.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 12 December 2014 Resolved
Alarm junction box placard label "Connection for barge Overflow Control System" not legible. Needs to be legible.
Action required: 705 - Other - as specified
Due 19 January 2015
Resolved 9 January 2015
Resolution: Reinstalled new label.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 December 2011 Resolved
#3 Stbd cargo tank high level alarm not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2011
Resolved 21 December 2011
Resolution: ERL technicain replaced sensors and tested sat.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 December 2011 Resolved
Broken clamp on prime mover exhaust piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2011
Resolved 21 December 2011
Resolution: New clamp installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.