Records from 2003 to 2021. Most recent: inspection, 22 September 2021.
Inspection history · 35
22 September 2021
Internal Structural Exam · Drydock Exam · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7316631
14 December 2020
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7111682
22 November 2019
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6870932
27 December 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6603128
14 December 2017
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6324523
7 December 2017
Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6322512
19 October 2017
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6290956
5 April 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6118382
26 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5862638
16 December 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5783492
9 March 2015
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5081059
19 December 2014
MTSA Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5038719
27 January 2014
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4789659
11 January 2012
Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4226315
11 January 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4237786
16 December 2011
Examination of Repairs · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4209530
20 January 2011
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3950198
11 January 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3662198
17 March 2009
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3435033
9 December 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3376844
7 March 2008
COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3162384
9 January 2007
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2852932
27 September 2006
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2788262
28 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2762039
11 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2621984
14 March 2006
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2602506
6 January 2006
Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2562175
5 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2452172
28 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2321497
18 March 2005
MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2320327
14 January 2005
Annual Inspection · MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2274985
10 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238831
20 February 2004
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2009905
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1984539
20 March 2003
Initial Construction-Excluding Oversight · Initial Certification · Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1749158
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 14 December 2020
Resolved
Each cargo tank of a tank barge must have the means to check the liquid overfill protection arrangements at the tank for proper operation prior to each loading. During the inspection, the portable alarm system indicated an incorrect alarming sequence due possibly to an improper installation. Verify and/or correct prior to conducting cargo loading operations. 46 CFR 39.20-9(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2020
Resolution: The alarms have been fixed and are working properly on the MAP 602.
Submitted by Chris Stafford
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 November 2019
Resolved
The emergency stop for the pump engine failed to shut the engine down.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 22 November 2019
Resolution: Fixed cabling and engine shit down as intended.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 November 2019
Resolved
Port #1 void hatch lid had a broken hinge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 10 December 2019
Resolution: Replaced lid
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 12 December 2014
Resolved
Slop Tank gauging system inoperable. Needs to be repaired or replaced.
Action required: 705 - Other - as specified
Due 19 January 2015
Resolved 9 January 2015
Resolution: Replace with new gauge stick.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 12 December 2014
Resolved
Alarm junction box placard label "Connection for barge Overflow Control System" not legible. Needs to be legible.
Action required: 705 - Other - as specified
Due 19 January 2015
Resolved 9 January 2015
Resolution: Reinstalled new label.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 December 2011
Resolved
#3 Stbd cargo tank high level alarm not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2011
Resolved 21 December 2011
Resolution: ERL technicain replaced sensors and tested sat.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 December 2011
Resolved
Broken clamp on prime mover exhaust piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2011
Resolved 21 December 2011
Resolution: New clamp installed.