Records from 1994 to 2024. Most recent: inspection, 18 September 2024.
Inspection history · 26
18 September 2024
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8004032
18 September 2024
COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8006280
15 August 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7980969
13 October 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7809863
1 February 2023
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7660574
26 January 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7628091
29 September 2021
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7323417
26 August 2021
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7298096
27 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7269942
15 October 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7070383
2 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6865639
16 July 2019
Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6745086
5 December 2013
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4764489
5 December 2013
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4764617
14 January 2013
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4517350
8 December 2010
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3907425
19 February 2010
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3684197
24 November 2009
Industry Initiated Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3642665
25 October 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3652066
14 October 2009
MTSA Verification · Spot Check (Safety)
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3615402
27 June 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3252721
31 August 2007
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3051032
24 August 2006
MTSA Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2757291
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1964462
3 September 1998
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 27822
23 February 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 46838
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine inspector observed leak coming out of STBD engine on inboard side between aft-most head and engine block. Make corrections to satisfaction of marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2024
Resolved 21 September 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 January 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The Following alarms must be provided: High bilge levels. Vessel did not have installed bilge alarms in any spaces and no bilge alarm panel in operating station. Vessel is to install and show proper operation of high level bilge alarm to attending CG inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2023
Resolved 1 February 2023
Resolution: Recieved photo and video evidence of installed working bige alarm system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 29 September 2021
Resolved
Essential systems of equipment must be regularly tested and examined. If a component is found unsatisfactory, it must be repaired or replaced. Soft patch on lube oil piping in aft lazarette is deteriorated and leaking. Replace temporary soft patch with fixed piping to the satisfaction of CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 15 October 2021
Resolution: Photo received showing newly installed lube oil piping.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 September 2021
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces. Remote stop for machinery space fans are inoperable. Repair to the satisfaction of CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 15 October 2021
Resolution: Received video showing remote san shutdowns now operational.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 September 2021
Resolved
The TVR (towing vessel record) must include a chronological record of events as required by this subchapter. The vessel's logbook book does not contain required entries of navigation assessments, pre-underway checks, fire drills, or times of watch relief. Provide two weeks of completed logs with required entries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 15 October 2021
Resolution: Vessel created new logbook with required entries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 September 2021
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 1 inch high: "WATERTIGHT DOOR-KEEP CLOSED or "WATERTIGHT HATCH-KEEP CLOSED". Watertight hatch on stern does not have required marking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 15 October 2021
Resolution: All hatches/doors have been labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 29 September 2021
Resolved
Each towing vessel certificated under the provisions of this subchapter must be in full compliance with the terms of the COI. The vessel failed to have required manning specified by the COI onboard during operations over 12 hours on multiple occasions.
Action required: 10 - Deficiency Rectified
Resolved 29 September 2021
Resolution: Notified vessel representative that the vessel was not in compliance with COI and enforcement would be issued.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 July 2021
Resolved
The design of the fire detection system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section. Vessel's fire detection system is not certified under 46 CFR subchapter M. Ensure fire-detection system meets requirements listed in 46 CFR 142.330 and provide documentation of certification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2021
Resolved 29 September 2021
Resolution: Received PE letter for fire detection system. Verified during def check.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 July 2021
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room vents are not capable of being closed. Install closure devices to satisfaction of CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2021
Resolved 29 September 2021
Resolution: Installed closure devices. Verified during def check.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 July 2021
Resolved
If the vessel is engaged other than in towing exclusively on Western Rivers—(A) Coast Guard Light List;(B) Notices to Mariners published by the National Geospatial-Intelligence Agency, or LNMs published by the Coast Guard;(C) Tidal-current tables published by private entities using data provided by the NOS, or river-current tables published by a river authority;(D) Tide tables published by private entities using data provided by the NOS; and (E) U.S. Coast Pilot. Vessel has outdated publications onboard. Replace with new versions or update existing publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2021
Resolved 29 September 2021
Resolution: Publications purchased. Verified during def check.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 July 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting in engine room is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2021
Resolved 29 September 2021
Resolution: Batteries replaced in emergency lighting. Verified during def check.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 27 July 2021
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Vessel's first aid cabinets have expired medicine and equipment. Inventory cabinets and replace expired medicine and equipment as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2021
Resolved 29 September 2021
Resolution: Vessel removed expired supplies. Verified during def check.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 July 2021
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Vessel's mast light is extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2021
Resolved 29 September 2021
Resolution: Mast light replaced. Verified during def check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2020
Resolved
Propulsion machinery, including main engines, must be maintained to ensure proper operation. Vessel was unable to start main/auxiliary engines during inspection. Vessel is required to demonstrate proper operation of propulsion machinery prior to any underway operations. 46 CFR 143.205(c)(1).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2020
Resolution: Witnessed proper operation of main engines while underway.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 October 2020
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. During testing, the Port side remote fuel shutoff device broke and is unable to open or close the fuel shutoff valve remotely. Repair remote shutoff device and prove proper operation prior to any underway operations. 46 CFR 143.260 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2020
Resolution: Witnessed repairs to valve handle and proper operatin of fuel shut off valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2020
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket for each person on board. Vessel had insufficient numbers of lifejackets onboard (6 of 10 required) which were also not marked with the vessel's name. Provide ten lifejackets onboard as required by vessel's COI and mark with vessel's name. 46 CFR 141.340 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 11 November 2020
Resolution: Received photo evidence that 10 properly marked lifejackets were placed on the vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2020
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire extinguishing systems must be inspected and tested at least once every 12 months. Vessel was unable to provide documentation attesting to the 12 month inspection and testing requirements of fire-fighting equipment and appliances. Provide evidence inspections and tests were completed within the past 12 months. 46 CFR 142.240 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 15 November 2020
Resolution: Received satisfactory documentation showing inspections and tests were completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2020
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel failed to provide documentation of enrollment in a random testing program for previous crewmembers. Provide documentation of enrollment for crewmembers working onboard for the months of July, August, September, and October. 46 CFR 16.210 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2020
Resolved 15 November 2020
Resolution: Received documentation showing crewmembers took pre-employment tests and were now enrolled in a random drug testing program.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2019
Resolved
Flexible connection and discharge hoses on all semi-portable extinguishers and fixed extinguishing systems must be inspected and tested in accordance with 46CFR147.65. The flexible hose connections from the distribution piping and cylinders were bubbled with the potential of corrosion. Replace the connection hoses and provide a re-certification of the system. Complete by 16Aug19.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2019
Resolved 2 December 2019
Resolution: Received Technician's report attesting to satisfactory test of fixed fire fighting system as required following replacement of weathered hoses, all sat.