Records from 2002 to 2026. Most recent: inspection, 1 April 2026.
Inspection history · 185
1 April 2026
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8395584
24 March 2026
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8319332
21 January 2026
Damage Survey · Periodic Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8299380
21 January 2026
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8306101
16 January 2026
Periodic Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8295129
9 October 2025
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8250063
17 September 2025
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8219685
25 June 2025
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8165572
7 April 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8093399
21 January 2025
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8063250
14 January 2025
Deficiency Check · MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8063291
11 December 2024
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8047038
20 September 2024
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8003202
27 June 2024
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7936728
20 March 2024
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7879626
4 January 2024
Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7844307
3 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7844793
27 September 2023
Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7795287
20 July 2023
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7748486
5 July 2023
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7727260
22 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7694113
5 April 2023
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7666753
1 March 2023
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7644282
13 February 2023
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7634511
4 February 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7632949
4 February 2023
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7633289
9 November 2022
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7590365
8 September 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536205
3 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7444001
30 March 2022
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417429
5 February 2022
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7400544
10 January 2022
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7378123
23 December 2021
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7371948
16 December 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7368012
14 November 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7350964
7 October 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7327541
26 July 2021
Special Consideration · Appeal
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7268380
14 July 2021
Damage Survey · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7255682
25 March 2021
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7158518
7 January 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7313513
14 October 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7074574
29 July 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7011166
6 April 2020
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935973
13 March 2020
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6923736
14 February 2020
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904629
10 October 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6831885
28 July 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7076729
10 July 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6744987
24 June 2019
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6724246
7 May 2019
Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6679403
9 April 2019
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6658013
14 March 2019
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6642294
25 February 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7075880
9 January 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6610603
9 January 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6610686
6 December 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6596027
12 November 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6580894
26 September 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6548114
25 June 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6455652
23 June 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6483868
6 March 2018
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6367010
17 January 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6342011
18 December 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6364840
13 December 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6334878
20 September 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6272407
17 September 2017
Drydock Exam · Hull Examination · Construction Oversight · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6268855
9 July 2017
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6204581
26 June 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6187667
16 March 2017
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6106133
13 March 2017
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6105214
9 January 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6068232
15 November 2016
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6041223
5 October 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6016834
20 July 2016
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5946898
27 June 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5922577
7 April 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5849425
17 March 2016
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5834969
18 February 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5818492
12 January 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5796181
19 November 2015
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5766769
30 September 2015
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5732451
5 August 2015
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5206723
2 October 2014
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4998530
3 August 2014
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4945620
26 June 2014
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4901413
20 May 2014
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4864340
16 May 2014
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4860490
21 March 2014
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4820595
12 March 2014
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4814991
22 July 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4390124
18 July 2012
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4383019
22 May 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4319575
4 May 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4304121
2 May 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4301099
1 May 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4299540
18 January 2012
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4227068
18 January 2012
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4234485
6 December 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4202992
6 December 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4203029
24 September 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4158151
1 September 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4134078
10 August 2011
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4111531
12 July 2011
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4081094
12 July 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4097019
16 February 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3954971
10 February 2011
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3943103
3 February 2011
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3938669
28 January 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3938644
21 January 2011
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3931562
11 January 2011
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3925009
9 December 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3907746
6 December 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3908275
3 December 2010
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3903784
3 November 2010
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3917003
25 October 2010
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3876931
11 March 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3702771
9 March 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3693777
12 February 2010
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3679077
11 February 2010
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3678714
15 January 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3664542
4 December 2009
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3644568
2 December 2009
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3643435
28 July 2009
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3548684
21 July 2009
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3541418
8 April 2009
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3444214
2 April 2009
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3444949
5 March 2009
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3428192
4 March 2009
Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3428641
2 February 2009
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3411570
29 January 2009
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3401859
19 January 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3396976
23 December 2008
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3384478
26 November 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3372976
25 September 2008
Deficiency Check · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3332128
3 September 2008
Plan Review (Other than "T")
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3316677
2 April 2008
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3175963
27 March 2008
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3172068
15 January 2008
Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3130111
23 December 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3122933
24 October 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3086327
23 October 2007
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3085180
12 July 2007
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2992547
3 July 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2981919
14 March 2007
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2887856
14 March 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2887886
14 March 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2887906
17 January 2007
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2856654
6 October 2006
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2795302
1 September 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3007961
7 July 2006
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2704723
30 June 2006
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2699959
28 March 2006
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2608314
1 March 2006
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2593876
20 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2521101
11 October 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2512076
27 September 2005
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2501121
19 September 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2496402
23 August 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2472443
26 July 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2440877
14 July 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2426554
2 July 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2411010
29 June 2005
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2408121
13 April 2005
Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2333289
28 March 2005
COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2321603
25 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2299120
20 January 2005
Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2272922
6 January 2005
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2275417
1 November 2004
In-Service Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2242623
28 October 2004
Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2227848
14 September 2004
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2195793
8 September 2004
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2192185
23 August 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2174067
7 July 2004
MTSA Verification · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2123192
8 June 2004
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2101414
6 April 2004
COI Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2036134
1 March 2004
Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2015604
5 February 2004
In-Service Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2161167
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1981713
18 November 2003
Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1947937
14 October 2003
Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1928197
8 September 2003
Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1897536
2 August 2003
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1902671
27 May 2003
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1803202
8 May 2003
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1788997
11 December 2002
Deadweight Survey · Initial Certification · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1792803
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 January 2026
Resolved
Each generator must meet the applicable requirements for construction and testing in 4-8-3 of ABS Rules. Number 2 generator experienced an electrical fire. Repair or replace #2 generator to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 24 March 2026
Resolution: Generator was replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 January 2026
Resolved
Each opening on a weather deck must have a means to make it weather-tight. Provide hatch gasket for steering space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2026
Resolved 24 March 2026
Resolution: all sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2026
Resolved
Provide maintenance records for generators #1 and #3. Provide manufacturers recommended maintenance schedule for generators #1 and #3. Specifically related to the electrical portion of the generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2026
Resolved 24 March 2026
Resolution: Vessel to overhaul and service remaining 2 generators and follow manufactures instructions for servicing going forward.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 September 2025
Resolved
Re-label Life rings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 9 October 2025
Resolution: MI verified that all life rings were properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2025
Resolved
re-strap various cable ways.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 9 October 2025
Resolution: MI verified that all cable ways were properly re-strapped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2025
Resolved
Provide an alternant means of safety until the camera system is installed and operational.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2025
Resolved 9 October 2025
Resolution: MI verified that all 26 cameras have been restored.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2025
Resolved
replace #17 Portable Extinguiser.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 September 2025
Resolved 17 September 2025
Resolution: Replaced prior to the completion of the inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2025
Resolved
Service gates to IBA area's
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 October 2025
Resolved 17 September 2025
Resolution: Serviced prior to the completion of inspection
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 17 September 2025
Resolved
remove water on deck in bar area under cooler and determine source.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 9 October 2025
Resolution: MI verified that all standing water has been properly removed. Bar area was found to be dry and in satisfactory condition.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 17 September 2025
Resolved
Remove oil from bilge in fwd. engine room
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 9 October 2025
Resolution: MI verified that all oil in bilge space in fwd engine room has been properly removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2025
Resolved
Cables to be permanently attached with metal
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2025
Resolved 16 July 2025
Resolution: Items were cleared,
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 11 April 2025
Resolved
Hose test all main passenger area windows
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2025
Resolved 16 July 2025
Resolution: Items were cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 April 2025
Resolved
Hydro-statically test sprinkler system following scheduled repairs. Piping must hold max system pressure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 11 April 2025
Resolved
Operationally test crane following planned repairs
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2025
Resolved 16 July 2025
Resolution: Tested and cleared
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 March 2025
Resolved
Repair sprinkler piping doublers in enginroom.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 16 July 2025
Resolution: Item was repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 March 2025
Resolved
Install the correct pressure gauge on start air piping. Current gauge only reads to 160psi.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 16 July 2025
Resolution: Item corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2025
Resolved
Replace 2 fire hoses that failed pressure tests.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 18 March 2025
Resolved 18 March 2025
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 March 2025
Resolved
Repair oil leak on generator.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 March 2025
Resolved 19 March 2025
Resolution: Leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2025
Resolved
Excessive used oil in the centerline of the engine room
bilge. Remove all oil.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2025
Resolved 24 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 January 2025
Resolved
The starboard aft fire door leading into the passenger accommodation space missing door latch and unable to securely fasten. Repair/ Replace latch.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 22 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2025
Resolved
Renew lifejacket storage placard on port aft tween deck storage container.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 19 March 2025
Resolution: MI witnessed a new placard had been installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 September 2024
Resolved
Repair vent shutdown on car deck gooseneck vent to Bow Prop space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2024
Resolved 2 October 2024
Resolution: Vent shutdown was repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 September 2024
Resolved
Post the current COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2024
Resolved 20 September 2024
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 20 March 2024
Resolved
PROVE PROPER OPERATION OF SECURING DEVICES (DOGS) FOR CARGO / STORES LOADING HATCH ON UPPER DECK.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 March 2024
Resolved 20 March 2024
Resolution: CORRECTED ON THE SPOT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 March 2024
Resolved
PROVE PROPER OPERATION OF #3 VOID BILGE SUCTION.
Action required: 10 - Deficiency Rectified
Due 20 March 2024
Resolved 20 March 2024
Resolution: CORRECTED PRIOR TO THE END OF INSPECTION.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024
Resolved
PROPERLY TAG OUT OR RETURN TO NORMAL SERVICE, #10 BREAKER IN 2G DISTRIBUTION PANEL LOCATED IN GALLEY.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 3 April 2024
Resolution: O/O provided photographic proof and attestment to the correction of this item. Breaker was properly tag/locked out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024
Resolved
PROPERLY SECURE ELECTRICAL CABLE IN GALLEY BEHIND FLOOR SAFE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 3 April 2024
Resolution: O/O provided photographic proof and attestment to the correction of this item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024
Resolved
REMOVE DEAD END CABLE AT AFT PORT CAR DECK NEAR SPEAKER.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2024
Resolved 3 April 2024
Resolution: O/O provided photographic proof and attestment to the correction of this item.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 March 2024
Resolved
REPLACE FIRE HOSE
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 March 2024
Resolved 20 March 2024
Resolution: CORRECTED ON THE SPOT, HOSE REPLACED.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 July 2023
Resolved
Throttle pressure regulator clogged resulting in a decrease in air pressure from 125 psi to 85 psi.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 August 2023
Resolved 21 July 2023
Resolution: Throttle pressure regulator repaired and operating as normal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 February 2023
Resolved
Prior to operating vessel in passenger service identify and rectify the cause of loss of control air to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 February 2023
Resolved 4 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 8 September 2022
Resolved
STBD main engine high gear oil temp alarm is in a defective state.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 15 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022
Resolved
Crop/Renew raw water pipes in void #2 (for A/C system).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 3 May 2022
Resolution: MI witnessed repairs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 March 2022
Resolved
In Engine Room (MSD Space) make permanent repair to hole in fire main in way of check valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 12 April 2022
Resolution: complete
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 30 March 2022
Resolved
Make permanent repair to rusted portion of access ladder to anchor/bow area at next dry dock 2022.
Action required: 705 - Other - as specified
Resolved 12 April 2022
Resolution: complete
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2022
Resolved
Repair seals in #3 generator, oil leak (governor).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 12 April 2022
Resolution: complete
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 March 2022
Resolved
Pack Engine Room bulkhead penetration on stbd side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 12 April 2022
Resolution: complete
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 30 March 2022
Resolved
Attach boiler relief valve down pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 12 April 2022
Resolution: complete
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 30 March 2022
Resolved
Support sewage pipe in MSD space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 3 May 2022
Resolution: MI witnessed the installation of support.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2022
Resolved
Secure smoke detector "D18" port side concessions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2022
Resolved 12 April 2022
Resolution: complete
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 July 2021
Resolved
When the main steering gear includes two or more identical power units, no auxiliary steering is need if the vessel can operate the rudder as required by (b)(2) of this section while any one of the power units is not operating. The #2 steering pump could not move the rudder stock as required if the #1 steering pump was not operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2021
Resolution: Pump replaced and tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 July 2021
Resolved
Remove oil soaked pads from elevator hydraulic unit. Repair elevator hydraulic system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 4 August 2021
Resolution: Pads remvoed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2021
Resolved
Remove all fuel from flame impingement bowls on port and stbd main engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 19 July 2021
Resolution: Oil removed and flame bowls cleaned.
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Ship security plan
Issued 25 March 2021
Resolved
Vessels security plan needs to be amended to reflect what is contained in the appendices vs. what is in the appendices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2021
Resolved 19 July 2021
Resolution: SSP updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2021
Resolved
Vessels #2 steering pump has a hydro license leak, approximately 1 oz per min. The seal leaks more when cold. Renew seal and prove proper operation of the #2 steering pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 19 July 2021
Resolution: Leak repaired. New pump installed.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 25 March 2021
Resolved
Prove proper operation of heigh water temp. on emergency generator and bow thruster. Both sensors broke while testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 19 July 2021
Resolution: Sensors replaced and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2021
Resolved
The fuel oil hand priming pump has a small leak. Repair hand pump and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 19 July 2021
Resolution: hand pump repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 25 March 2021
Resolved
Vessels main deck port forward life ring water light is cracked and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 19 July 2021
Resolution: New water light installed.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 25 March 2021
Resolved
Fire alarm light in bow thruster does not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 19 July 2021
Resolution: New light installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 July 2020
Resolved
Repair or replace E/R smoke detector (stbd side) D37.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 15 October 2020
Resolution: verified on inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2020
Resolved
Replace bilge straininer in steering room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 15 October 2020
Resolution: verified on inspection
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 July 2020
Resolved
Repair hanging light in steering space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 14 October 2020
Resolution: verified on inspection
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 March 2020
Resolved
Repair or replace smoke detector D19 in main passenger cabin. Detector was operational; however the outer casing was damaged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2020
Resolved 29 July 2020
Resolution: New smoke detector installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 March 2020
Resolved
VHF radios do not provide latitude and longitude. Ensure VHF DSC radios can relay position information.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2020
Resolved 29 July 2020
Resolution: VHF radio's now have lat and long.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 March 2020
Resolved
Mag. compasss is inaccurate. Complete deviation test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2020
Resolved 29 July 2020
Resolution: New compass deviation test performed and updated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2020
Resolved
During fire hose pressure test 01 hose failed. A new hose was provided.
Action required: 10 - Deficiency Rectified
Due 13 March 2020
Resolved 13 March 2020
Resolution: New hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 March 2020
Resolved
Provide suitable insulation for stbd M/E lube oil jacket water cooling line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2020
Resolved 29 July 2020
Resolution: M/E lube oil jacket water cooling line was insulated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2020
Resolved
Remove all oil soaked sorbent pads from M/E and generators.
Action required: 10 - Deficiency Rectified
Due 13 March 2020
Resolved 13 March 2020
Resolution: Oil pads were removed.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 10 July 2019
Resolved
Engineer's alarm needs to be installed in Engineers state room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2019
Resolved 13 March 2020
Resolution: Alarm installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2019
Resolved
New cable from state rooms to main electrical panal needs to be secured to the bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2019
Resolved 13 March 2020
Resolution: Cable secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2019
Resolved
Replace directional control valve on the #2 pump valve is leaking.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2019
Resolved 11 July 2019
Engineering › Bilge Water Management System › Not Operational
Issued 6 March 2018
Resolved
Pressure guages on the bilge pumps were not operational
Due 28 April 2018
Resolved 25 June 2018
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 6 March 2018
Resolved
Engine was leaking lube oil from the stbd side
Due 28 April 2018
Resolved 25 June 2018
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 6 March 2018
Resolved
#1 SSG Reverse Power Relay did not function
Due 28 April 2018
Resolved 25 June 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 17 January 2018
Resolved
Repair light fixtures in Eng Room 1 PS 1 STBD 1 PS MSD space and 1 STBD rudder space. 2 STBD side car deck AFT.
Due 17 February 2018
Resolved 25 June 2018
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 17 January 2018
Resolved
Repair low oil pressure alarms on #1 and #2 bow thrusters.
Due 17 February 2018
Resolved 25 June 2018
Engineering › Fuel Oil Service System › Hose
Issued 26 June 2017
Resolved
Chafed high pressure fuel oil hoses from oil filter to pump on both port and stbd main engines
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 20 September 2017
Engineering › Thrusters › Hose
Issued 26 June 2017
Resolved
Replace chafed fuel return line on #2 bow thruster
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 20 September 2017
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 26 June 2017
Resolved
Replace #1 bow thruster water temperature sensor.
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 20 September 2017
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 9 January 2017
Resolved
Repair jacketwater leaks in both bow thruster engines.
Due 9 March 2017
Resolved 29 March 2017
Accommodation/Occupational Safety › Heating › Piping
Issued 9 January 2017
Resolved
Blank off old A/C overboard discharge lines, both port and starboard sides in engine room.
Due 9 March 2017
Resolved 29 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 9 January 2017
Resolved
Repair extinguished light fixture, starboard upper car deck, IWO fire station #2.
Due 16 January 2017
Resolved 29 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 9 January 2017
Resolved
Repair (2) extinguished lights on aft car deck.
Due 16 January 2017
Resolved 29 March 2017
Fire Fighting › Fire Hydrants › Condition
Issued 9 January 2017
Resolved
Exercise all fire station hydrant valves.
Due 16 January 2017
Resolved 29 March 2017
Construction/Loadline › Structures › Door
Issued 30 March 2016
Resolved
Repair/replace wheel guide on the Bow Door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Engineering › Fuel Oil Service System › Valve, Control
Issued 30 March 2016
Resolved
Repair Fuel leak at PORT / Starboard B/T Emergency Fuel Shut Off Valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Engineering › Steam Boiler (auxiliary/waste heat) › Regulator
Issued 30 March 2016
Resolved
Provide manufacturers test procedures for package boiler test IAW
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 29 March 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 March 2016
Resolved
Correct label all E Power lights on Car deck.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Engineering › Thrusters › Motor
Issued 30 March 2016
Resolved
Conduct over speed on FWD Bow Thruster.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Engineering › Thrusters › Motor
Issued 30 March 2016
Resolved
Conduct HI Jacket water test on AFT Bow Thruster.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 30 March 2016
Resolved
Conduct Low Fuel Alarm on P/S fuel tanks.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 30 March 2016
Resolved
Repair leak at union on zone 3, sprinkler heads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 31 March 2016
Resolution: System fixed.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 30 March 2016
Resolved
Clear 2 sprinkler heads zone 4/5 center upper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 7 April 2016
Lifesaving › Buoyant Smoke Signals › General
Issued 19 February 2016
Resolved
Sun deck water light was cracked
Due 30 March 2016
Resolved 7 April 2016
Fire Fighting › Nozzles › Location
Issued 19 February 2016
Resolved
Provide blow off cap for forward nozzel on deli fryer wet chemical extinguishing system
Due 30 March 2016
Resolved 23 March 2016
Lifesaving › Rescue Boat › Drain Valve
Issued 19 February 2016
Resolved
Replace scupper drain hoses
Due 30 March 2016
Resolved 23 March 2016
Electrical › Electric Supply System (service) › Cable
Issued 19 February 2016
Resolved
Remove dead end wiring on car deck stbd side aft
Due 30 March 2016
Resolved 7 April 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 November 2015
Resolved
Watertight closure indicator at the operating station for the engine room watertight door was inoperable
Condition: Improper Installation
Due 19 December 2015
Resolved 12 January 2016
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 19 November 2015
Resolved
All onboard weekly/monthly maintenance/safety check sheets need to be updated to reflect current onboard equipment
Condition: Invalid
Due 26 January 2016
Resolved 19 February 2016
Resolution: New check sheet provided.
Communications › Visual Communication › Warning Sign (gangway)
Issued 5 August 2015
Resolved
Label Port side upper deck Emergency Hatch
Due 5 September 2015
Resolved 28 September 2015
Resolution: Hatch labeled.
Lifesaving › Lifebuoys › Serviceable
Issued 5 August 2015
Resolved
Replace retro tape on all identified life rings
Due 5 September 2015
Resolved 28 September 2015
Resolution: Life bouy retro tape replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 August 2015
Resolved
Lable emergency light fixtures located on the car deck
Due 5 September 2015
Resolved 28 September 2015
Resolution: Emergency light labeled.
Construction/Loadline › Structures › Door
Issued 5 August 2015
Resolved
Repair door latch stbd fwd on main car deck
Due 5 September 2015
Resolved 12 January 2016
Engineering › Fuel Oil Service System › Valve
Issued 5 August 2015
Resolved
Remove/properly install ball valve on emergency generator fuel supply line
Due 5 September 2015
Resolved 28 September 2015
Resolution: Valve replaced.
Fire Fighting › Fire Hydrants › Condition
Issued 2 October 2014
Resolved
Repair hydrant at fire staton #27.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Valve replaced on fire station #27.
Fire Fighting › Fire Hydrants › Material
Issued 2 October 2014
Resolved
Provide longer lanyard for spanner wrench at fire station #17.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Lanyard attached on spanner wrench.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 October 2014
Resolved
Secure J-box on port aft car deck.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: J-box secured.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 October 2014
Resolved
Replace fire extinguisher #20 bracket, (car deck).
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Bracket replaced.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 2 October 2014
Resolved
Provide proper sized dog wrench at stbd embarkation station.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Dog wrench provided.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 October 2014
Resolved
Replace hydraulic lines on #1 & #2 steering system in MSD space.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Hydraulic lines replaced.
Engineering › Steering Gear System › Ram Seal
Issued 2 October 2014
Resolved
Replace leaking seal on stbd steering ram.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Leaking seal on stbd steering ram replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 October 2014
Resolved
Install time delay bypass on Egen CO2 system as designed.
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 10 December 2014
Resolution: Time delay installed.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 26 June 2014
Resolved
Clean under oven/fryer remove grease
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Grease removed under oven/fryer.
Engineering › Lubricating Oil Service System › Hose
Issued 26 June 2014
Resolved
Replace L/O line on stbd eng.
Action required: 705 - Other - as specified
Due 2 November 2014
Resolved 10 December 2014
Resolution: Lube line replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 June 2014
Resolved
Fire Ext #2 PORT side missing glass cover
Due 26 July 2014
Resolved 2 October 2014
Resolution: Glass replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 June 2014
Resolved
Replace brackets on exit signs FWD PORT and STBD on weather deck. Will be conducted at next dry dock inspection.
Action required: 705 - Other - as specified
Resolved 1 April 2015
Resolution: Brackets have been replaced.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 June 2014
Resolved
Fix leak on STBD MSD sensor
Due 26 July 2014
Resolved 2 October 2014
Resolution: Solid plate installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 June 2014
Resolved
Replace brackets on exit signs and brackets fwd port and stbd weather deck.
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 27 June 2014
Engineering › Steering Gear System › Hydraulic Hose
Issued 12 March 2014
Resolved
Install chafing gear on hydraulic hose.
Due 1 May 2014
Resolved 3 April 2014
Resolution: Chafing gear installed.
Engineering › Steering Gear System › Differential Assembly
Issued 12 March 2014
Resolved
Re-new Bow thruster L/O caps on both engine transmissions.
Due 30 June 2014
Resolved 26 June 2014
Resolution: 02 new L/O caps were installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 March 2014
Resolved
Conduct MOB drill / rescue boat operation.
Due 30 June 2014
Resolved 26 June 2014
Resolution: MOB drill was witnessed sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 12 March 2014
Resolved
Replace CO2 bottles with RFI bottles. Bottles need hydrostatic test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2014
Resolution: RFI bottles installed. Time delay and alarm tested.
Engineering › Steering Gear System › Hydraulic Hose
Issued 12 March 2014
Resolved
Repair leak on AFT steering pump
Due 1 May 2014
Resolved 3 April 2014
Resolution: Leak repaired. O-ring replaced.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 18 January 2012
Resolved
Port side shoretie locking ring missing. Provide lock ring to electrical shoretie port side aft.
Action required: 705 - Other - as specified
Due 30 October 2012
Resolved 15 January 2013
Lifesaving › Launching Appliances › Davit
Issued 12 July 2011
Resolved
Replace wasted bracket on Rescue Boat davit accumulator.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 9 August 2011
Fire Fighting › Structural - A Class Divisions › Windows
Issued 12 July 2011
Resolved
Repair window clips to prevent the rescue boat painter from snagging on them.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 9 August 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2011
Resolved
Secure wiring in elevator J-box.
Due 14 October 2011
Resolved 9 August 2011
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 July 2011
Resolved
Repair various leaks on port MSD system
Due 14 October 2011
Resolved 18 January 2012
Resolution: Attended vessel, MSD system being repiped.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 July 2011
Resolved
Repair stripped bolts on port MSD C-cell lid.
Due 14 October 2011
Resolved 9 August 2011
Engineering › Fuel Oil Service System › Piping
Issued 12 July 2011
Resolved
repair fuel leak on #1 bow thruster engine check valve.
Due 14 October 2011
Resolved 9 August 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 February 2011
Resolved
Install permanent electrical outlet on bridge.
Due 10 March 2011
Resolved 8 March 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 February 2011
Resolved
Separate child PFD's from adult at stowage location port cabinet.
Due 10 March 2011
Resolved 8 March 2011
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 10 February 2011
Resolved
Service sliding fire-control boundary doors to ensure automatic closure.
Due 10 March 2011
Resolved 8 March 2011
Engineering › Fuel Oil Service System › Valve
Issued 10 February 2011
Resolved
Repair F/O leak on port MDE supply valve
Due 10 March 2011
Resolved 8 March 2011
Engineering › Sea-water System (primary cooling) › Pump
Issued 10 February 2011
Resolved
Repair R/W pump on port sewage system.
Due 10 March 2011
Resolved 8 March 2011
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 10 February 2011
Resolved
Replace flex hose on water gauge line #1MDE
Due 10 March 2011
Resolved 8 March 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 October 2010
Resolved
Prove watertight integrity of stbd steering access hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2010
Resolved 11 January 2011
Resolution: Crew repaired hatch and proved watertight integrity.
Electrical › Lighting (service) › Conductor
Issued 25 October 2010
Resolved
Starboard fiddly (e/r) 220v welder supply need insulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 November 2010
Resolved 11 January 2011
Resolution: Crew corrected deficiency by hard wiring supply outlet to breaker panel.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 25 October 2010
Resolved
Repair/Replace tachometer on stbd bridge wing (readings are high).
Action required: 705 - Other - as specified
Due 26 November 2010
Resolved 11 January 2011
Resolution: Crew replaced tachometer.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 25 October 2010
Resolved
Repair/Replace tachometer on port bridge wing (not reading forward/aft).
Action required: 705 - Other - as specified
Due 26 November 2010
Resolved 11 January 2011
Resolution: Crew replaced tachometer.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 February 2010
Resolved
Remove excessive water from engine room bilge.
Due 16 February 2010
Resolved 8 April 2010
Resolution: Bilge water removed. Dripless shaft seals will be installed at next drydock.
Construction/Loadline › Structures › Door
Issued 12 February 2010
Resolved
Repair door to elevator vestibule; 01 deck. Door does not completely close.
Due 26 November 2010
Resolved 11 January 2011
Resolution: Crew replaced handle on door, test sat.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 February 2010
Resolved
Replace broken glass on the following FSDs:
A. Starboard upper car ramp forward.
B. Port main car deck forward.
Due 26 February 2010
Resolved 8 April 2010
Resolution: Windows replaced.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 February 2010
Resolved
Provide exterior vent for crew toilet. To be corrected at next yard period.
Action required: 705 - Other - as specified
Resolved 10 February 2011
Fire Fighting › Ventilation Systems › Ducts
Issued 12 February 2010
Resolved
Provide louver for engine room ventilation system.
Due 26 February 2010
Resolved 8 April 2010
Resolution: Louver provided.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 February 2010
Resolved
Remove excessive combustibles material from MSD space.
Due 26 February 2010
Resolved 8 April 2010
Resolution: Excessive materials removed.
Construction/Loadline › Structures › Scuttle
Issued 12 February 2010
Resolved
Make repairs to aft steering space hatch.
Due 26 February 2010
Resolved 8 April 2010
Resolution: Hatch repaired.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 February 2010
Resolved
Remove hydraulic oil from aft steering space.
Due 16 February 2010
Resolved 8 April 2010
Resolution: Oil removed.
Engineering › Bilge Water Management System › Pump
Issued 12 February 2010
Resolved
Prove operation of port shaft sump pump.
Due 26 February 2010
Resolved 8 April 2010
Resolution: Pump repaired.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 28 July 2009
Resolved
Provide lids for all waste receptacles.
Due 28 August 2009
Resolved 28 August 2009
Resolution: Sighted lids
Lifesaving › Launching Appliances › Winch Brake
Issued 28 July 2009
Resolved
Adjust control cables so that they operate properly from all stations, in the vessel and at the winch.
Due 28 August 2009
Resolved 3 September 2009
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 28 July 2009
Resolved
Adjust fire doors at: Port Aft main DK, Port FWD WX Dk., Strb Car deck ramp aft so that they close properly.
Due 28 August 2009
Resolved 28 August 2009
Resolution: Tested doors
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 28 July 2009
Resolved
Clear the nozzles in zone 5 (fwd inboard on port ramp) and 6 (stb car ramp) of the car deck sprinkler system.
Due 28 August 2009
Resolved 28 August 2009
Resolution: Tested system
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 28 July 2009
Resolved
Make repairs to Temp gauge for #3 Generator
Due 28 August 2009
Resolved 28 August 2009
Resolution: Gauge repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 28 July 2009
Resolved
Prove operation of all lights in Steering Space.
Due 28 August 2009
Resolved 3 September 2009
Construction/Loadline › Structures › Scuttle
Issued 28 July 2009
Resolved
Make repairs to scuttle to steering space and prove watertight integrity.
Due 28 August 2009
Resolved 3 September 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 July 2009
Resolved
Make repairs to vent on Sea Chest in AFT engine room. Leaks water
Due 28 August 2009
Resolved 28 August 2009
Resolution: Vent fixed
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2009
Resolved
Make repairs to power cable for light over port workbench in engine room.
Due 28 August 2009
Resolved 28 August 2009
Resolution: Light fixture repaired
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 28 July 2009
Resolved
Remove plastic trash can from engine room.
Due 28 August 2009
Resolved 28 August 2009
Resolution: Trash can removed
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 April 2009
Resolved
Fire door at STBD aft main deck ladder well does not automatically close.
Due 22 April 2009
Resolved 6 May 2009
Resolution: Proved proper operation of fire door at STBD aft main deck ladder well.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 8 April 2009
Resolved
Replace wasted hydraulic hoses for cargo crane. Also replace several severely rusted flare nuts.
Due 30 June 2009
Resolved 6 May 2009
Resolution: Replaced wasted hydraulic hoses for cargo crane and replaced numerous rusted flare nuts.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 April 2009
Resolved
Exit signs were inoperable at Port and STBD fwd ladderwells at the car deck, when operating on emergency power.
Due 15 April 2009
Resolved 28 July 2009
Resolution: Sighted working lights.
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 8 April 2009
Resolved
Correct re-starting problems with emergency diesel generator set. Electric starter re-engaged after CO2 system activated shutdown prime mover.
Due 15 April 2009
Resolved 28 July 2009
Resolution: Tested Sat
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 8 April 2009
Resolved
Perform satisfactory six year servicing requirements on 50 pound ABC extinguisher in Engine room.
Due 22 April 2009
Resolved 6 May 2009
Resolution: Provided proof of servicing for 50 pound semi-portable extinguisher in Engine room.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 April 2009
Resolved
Provide (2) 10 pound serviced/charged BII portable extinguishers onboard to replace 2 that are currently due for six year service.
Due 9 April 2009
Resolved 6 May 2009
Resolution: Provided (2) 10 pound serviced/charged B-II portable CO2 extinguishers onboard to replace 2 that are currently out for six year servicing.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 8 April 2009
Resolved
Replace worn operating control cable on lifeboat davit
Due 30 June 2009
Resolved 28 July 2009
Resolution: Sighted new cables on vessel.
Fire Fighting › Grease Extraction Hood › General
Issued 8 April 2009
Resolved
Provide satisfactory service report for galley fixed fire extinguishing system prior to using galley while passengers are onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: Provided servicing report for galley fixed fire extinguishing system the day after the inspection was completed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 April 2009
Resolved
Repair exit signs on main deck at FWD port and stbd ladderwells.
Due 15 April 2009
Resolved 6 May 2009
Resolution: Repaired exit signs on main deck at FWD port and stbd ladderwells.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 April 2009
Resolved
Providing blanking cover for open slot on port side forward electrical panel on bridge.
Due 15 April 2009
Resolved 28 July 2009
Resolution: New cover sighted.
Construction/Loadline › Hull › Transverse Frame
Issued 4 March 2009
Resolved
The SPONSON MODIFICATION FRAME 5-20 presented on JOHN W. GILBERT Associates, Inc. drawing D-323-100 dated 1/09 shall be accomplished at the next scheduled drydocking and no later than 30 APR 10.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 4 May 2010
Resolution: Examined modifications.
Construction/Loadline › Hull › Transverse Frame
Issued 29 January 2009
Resolved
Upset frames & stiffeners in bow thruster space. Grind out Fx welds and re-weld.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 25 June 2009
Resolution: MI attended vessel and cleared requirement
Construction/Loadline › Hull › Transverse Frame
Issued 29 January 2009
Resolved
Make available for internal exam, (chemist cert safe for workers), all spaces below main deck forward of the bow thruster space.
Action required: 705 - Other - as specified
Due 4 March 2009
Resolved 25 June 2009
Resolution: MI attended vessel and cleared requirement
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 September 2008
Resolved
Replace expired EPIRB battery.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Replaced expired EPIRB battery.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 September 2008
Resolved
Replace all expired first aid kit medications with current meds.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Replaced all expired first aid kit medications with current meds.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 September 2008
Resolved
Properly secure all garbage cans to ensure they are secure for sea under any conditions.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Properly secured all garbage cans throughout vessel.
Electrical › Lighting (service) › Switch
Issued 25 September 2008
Resolved
Repair light switch under starboard side of bar.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Repaired light switch under starboard side of bar.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 25 September 2008
Resolved
Replace cover for receptacle outlet in aft bar.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Replaced cover for receptacle outlet in aft bar.
Fire Fighting › Fire Hoses › Number
Issued 25 September 2008
Resolved
Stencil fire hose station # 22.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Stenciled fire hose station # 22.
Construction/Loadline › Structures › Scuttle
Issued 25 September 2008
Resolved
Make necessary repairs to scuttle for forpeak.
Due 10 October 2008
Resolved 7 October 2008
Resolution: Made repairs to scuttle for forpeak.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 27 March 2008
Resolved
Repack electrical penetration in bulkhead between the fuel tank and water tank voids. (Depth sounder cable).
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 January 2009
Resolution: Completed sat.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 15 January 2008
Resolved
Continue to review, update & edit the ships Periodic Safety Test Procedures. Submit to OCMI for review a rough draft NLT 1/2/08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2009
Resolved 21 July 2009
Resolution: Received and implemented. See special note of 21JUL09.
Stability › Watertight Integrity › General
Issued 15 January 2008
Resolved
The watertight door in aft bhd of engine room closes too fast. Adjust closure time to between 20 & 40 seconds.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 9 April 2008
Resolution: Door closed within the required 20-40 second window.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 15 January 2008
Resolved
Properly label EOT power failure alarm on the bridge repeater for the machinery automation alarm system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 15 January 2008
Resolution: label installed to ID the alarm light.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 15 January 2008
Resolved
Review the operating system for the EOT power failure alarm installed to the EOT station on the bridge & determine the operational function that will cause the alarm to activate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 9 May 2008
Resolution: This power failure indicator light was part of the original equipment, but the circuit was installed and wired to the ships main alarm system, which operates correctly.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 October 2007
Resolved
Portable CO2 fire extinguishers are due for hydro test this month.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 25 October 2007
Resolution: Service company provided CO2 BII portables with current hydro dates. Verified during third Qrtly exam.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 October 2007
Resolved
Prove proper operation of fire detection system in galley stores/cooking space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 15 January 2008
Resolution: Heat detector tested satisfactorily during periodic exam. Unit was misidentified during exam as a smoke detector.
Fire Fighting › Means of Escape › Blocked
Issued 23 October 2007
Resolved
Provide a key to release the escape door on from the stack space at the upper deck level. A means of operating the door release from the outside is needed should the internal release not be accessible for escape or rescue.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 15 January 2008
Resolution: A release key has been provided in the near proximity of the escape door that is capable of operating the door from the outside.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 October 2007
Resolved
Replace inoperative heat detector in the paint locker.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 15 January 2008
Resolution: Verified compliance during third qtrly. Replacement in kind w/ a new detection unit was icompleted by engineer.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 23 October 2007
Resolved
Conduct general housekeeping in paint locker. Remove materials stored and debris IWO fixed CO2 system.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 31 October 2007
Resolution: Verified during 3rd Qtrly exam.
Fire Fighting › Grease Extraction Hood › General
Issued 12 July 2007
Resolved
Have Grease Extraction Hood on galley range serviced. Service inspection sticker is expired.
Due 20 July 2007
Resolved 17 August 2007
Resolution: Grease Extraction hood on galley range was serviced.
Construction/Loadline › Structures › Superstructure
Issued 12 July 2007
Resolved
Replace missing port hole cover on vessels superstructure, leading to crew's quarters.
Due 20 July 2007
Resolved 17 August 2007
Resolution: Replaced missing port hole cover on vessels superstructure, leading to crew''s quarters.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 March 2007
Resolved
Repair fractures in forward bulkhead of bowthruster space at lower port and stbd. chine.
Due 15 April 2007
Resolved 7 May 2007
Resolution: Repaired fractures in forward bulkhead of bowthruster space at lower port and stbd. chine.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 March 2007
Resolved
Repair multiple fractures in frames within bow thruster space in way of chine step port and stbd.
Due 15 April 2007
Resolved 7 May 2007
Resolution: Repaired multiple fractures in frames within bow thruster space in way of chine step port and stbd.
Engineering › Steering Gear System › Ram
Issued 14 March 2007
Resolved
Repair oil leak in stbd steering ram.
Due 15 April 2007
Resolved 7 May 2007
Resolution: Repaired oil leak in stbd steering ram.
Construction/Loadline › Penetrations › Weld
Issued 14 March 2007
Resolved
Repair fractured weld at base of aft engine wire race in bow thruster space.
Due 15 April 2007
Resolved 7 May 2007
Resolution: Repaired fractured weld at base of aft engine wire race in bow thruster space.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 March 2007
Resolved
Renew worn gasket on fire door to paint locker.
Due 15 April 2007
Resolved 7 May 2007
Resolution: Renewed worn gasket on fire door to paint locker.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 14 March 2007
Resolved
Clean all spaces under galley counters and equipment.
Due 4 April 2007
Resolved 7 May 2007
Resolution: Cleaned all spaces under galley counters and equipment.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 17 January 2007
Resolved
Renew faded IBA instruction cards on upper passenger deck.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Renewed all faded IBA instruction cards on upper passenger deck with new cards.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 January 2007
Resolved
Eliminate dead end wire in galley overhead.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Removed all dead end wire in the galley overhead.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 17 January 2007
Resolved
Remove all ice and water from containment on the lower car deck.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Removed all ice and water from containment on the lower car deck.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 January 2007
Resolved
Replace portable fire extinguisher # 22 on the aft lower car deck.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Replaced portable fire extinguisher # 22 on the aft lower car deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 January 2007
Resolved
Check all emergency exit signs on the upper and lower car decks to ensure proper operation.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Checked all emergency exit signs on the upper and lower car decks to ensure proper operation.
Construction/Loadline › Structures › Door
Issued 17 January 2007
Resolved
Repair Port and Stbd aft main passenger deck doors so as to ensure proper closing.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Repaired Port and Stbd aft main passenger deck doors so as to ensure proper closing.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 17 January 2007
Resolved
Mount and secure battery covers in engine room.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Mounted and secured battery covers in engine room.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 January 2007
Resolved
Properly secure junction box forward of boiler.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Properly secured junction box forward of boiler.
Engineering › Steering Gear System › Follow-up Assembly
Issued 17 January 2007
Resolved
Repair port hydralic electric connection to directional control valve.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Repaired port hydralic electric connection to directional control valve.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 January 2007
Resolved
Install locking pin on rudder room hatch cover.
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: Installed locking pin on rudder room hatch cover.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 6 October 2006
Resolved
Prove proper operation of reverse power relay between all SSDG'S
Due 20 October 2006
Resolved 20 October 2006
Resolution: Provided proof of proper operation of reverse power relay''s between all SSDG''s
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 October 2006
Resolved
Repair Starboard stair tower door to proper operation.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Repaired Starboard stair tower door to proper operation.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 October 2006
Resolved
Tighten both shaft packings.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Tightened both shaft packings to reduce leakage.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 October 2006
Resolved
Prove reliable operation of engine room vent fan/ controller overheating causing it to trip.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Provided proof of reliable operation of engine room vent fan controller.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 October 2006
Resolved
Replace break glass on CO2 control valve for the EDG space.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Replaced break glass on CO2 control valve for the EDG space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 October 2006
Resolved
Remove deadend wire in boiler room space.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Removed deadend wire in boiler room space.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 6 October 2006
Resolved
Plug open spots in deck and bulkhead wire penetrations in the boiler room.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Plug open spots in deck and bulkhead wire penetrations in the boiler room.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 6 October 2006
Resolved
Clean vent hood and duct work in galley.
Due 20 October 2006
Resolved 20 October 2006
Resolution: Cleaned vent hood and duct work in galley.
Electrical › Electric Generation Source (service) › Generator
Issued 7 July 2006
Resolved
Repair #1 SSDG Voltage Regulator
Condition: Unknown
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2006
Resolved
Repair Shore Tie cable.
Condition: Damaged By Earlier Event
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 July 2006
Resolved
Repair/prove proper operation of reverse power relay for #3 SSDG
Condition: Unknown
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Accommodation/Occupational Safety › Messroom › Size
Issued 7 July 2006
Resolved
Clean under serving line in Galley.
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 July 2006
Resolved
Clean/clear out items stored and repair lighting in referigeration space
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 July 2006
Resolved
Remove trash cans from stair towers.
Condition: Improper Installation
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 7 July 2006
Resolved
Repair accomodation access doors so that all close properly.
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 24 July 2006
Resolution: 24JUL06: Received letter from O/O attesting to clearance of all items issued under this activity.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 October 2005
Resolved
Repair/replace lighting fixtures in CO2 room (port side), steering compartment center light, and all lights in void #5 .
Due 1 November 2005
Resolved 28 March 2006
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 27 September 2005
Resolved
Pride proof of or conduct required weight test of rescue boat.
Condition: Unknown
Due 25 October 2005
Resolved 20 October 2005
Resolution: 21 bags of 60lb of sand were used.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 September 2005
Resolved
Repair/replace fire extiguisher bracket at station #22.
Condition: Improper/Lack of Maintenance
Due 25 October 2005
Resolved 20 October 2005
Resolution: moved fwd of where was because cars kept rubing against it.
Engineering › Steam Boiler (auxiliary/waste heat) › Gauge Glass
Issued 27 September 2005
Resolved
Replace cracked Fire eye glass on burner.
Condition: Unknown
Due 25 October 2005
Resolved 20 October 2005
Resolution: 14NOV05: Def Check, Received letter from owner operator attesting to completion of all 835''''s issued.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2005
Resolved
Repair mounting bracket on light fixture at port side steering room.
Condition: Improper/Lack of Maintenance
Due 25 October 2005
Resolved 20 October 2005
Resolution: 14NOV05: Def Check, Received letter from owner operator attesting to completion of all 835''''''''s issued.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 27 September 2005
Resolved
De-water and clean out all fuel oil containments on car deck.
Condition: Unknown
Due 25 October 2005
Resolved 20 October 2005
Resolution: !4NOV05: Def Check, Received letter from owner operator attesting to completion of all 835''''s issued.
Deck/Cargo › Cargo Stowage › General
Issued 27 September 2005
Resolved
Replace retaining clip on cargo hoist hook.
Condition: Unknown
Due 25 October 2005
Resolved 20 October 2005
Resolution: !4NOV05: Def Check, Received letter from owner operator attesting to completion of all 835''s issued.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 June 2005
Resolved
Label emergency egress from MSD room.
Condition: Unknown
Due 21 July 2005
Resolved 20 October 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 June 2005
Resolved
Post operating instructions for galley fire suppression system.
Condition: Unknown
Due 21 July 2005
Resolved 20 October 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 June 2005
Resolved
Replace pump seal on port MSD macerator pump.
Condition: Unknown
Due 21 July 2005
Resolved 20 October 2005
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2005
Resolved
Prove proper operation of all generator reverse power relay devices.
Condition: Improper/Lack of Maintenance
Due 21 July 2005
Resolved 20 October 2005
Engineering › Thrusters › Blade
Issued 13 April 2005
Resolved
Remove line from port and stbd bow thrusters
Due 13 May 2005
Resolved 20 October 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 April 2005
Resolved
Label both vehicle decks with NO SMOKING signs.
Due 13 May 2005
Resolved 29 June 2005
Resolution: Complete.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 April 2005
Resolved
Replace burned out light in steering cmpt, CO2 room aft port side, void 5 stbd side.
Due 13 May 2005
Resolved 20 October 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 April 2005
Resolved
Replace missing bolt in void 6, bay 3, overhead stbd side in pipe bracket
Due 13 May 2005
Resolved 20 October 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 28 March 2005
Resolved
Remove oily water from engineroom bilge prior to 11 Apr 05.
Due 11 April 2005
Resolved 13 April 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 March 2005
Resolved
Re-label breaker panels throughout ship, ensure labelled amperages match breakers prior to 11 Apr 05.
Due 11 April 2005
Resolved 22 April 2005
Resolution: As per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 January 2005
Resolved
Provide plan information for electrical installation in new elevator vestibules. Submit to local OCMI, prior to 20 Feb 05.
Due 20 February 2005
Resolved 10 February 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 28 October 2004
Resolved
Remove oily water and debris from engineroom and bowthruster room bilges.
Due 14 November 2004
Resolved 1 December 2004
Resolution: Per faxed ltr from Port Engineer, ltr scanned into documents section of activities.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 October 2004
Resolved
Repair or replace fire extinguisher #22's mounting bracket.
Due 14 November 2004
Resolved 3 November 2004
Resolution: Per faxed ltr from Master, ltr scanned into documents section of vsl details.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 28 October 2004
Resolved
Provide tamperseal on fire extinguishers #5, 10, 19.
Due 14 November 2004
Resolved 3 November 2004
Resolution: Per faxed ltr from Master, ltr scanned into documents section of vsl details.
Fire Fighting › Fire Hydrants › Condition
Issued 28 October 2004
Resolved
Connect spanner wrenches to fire station #17 and unmarked station on stbd side of #17.
Due 14 November 2004
Resolved 3 November 2004
Resolution: Per faxed ltr from Master, ltr scanned into documents section of vsl details.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 7 July 2004
Resolved
Adjust fire dooron lower car deck starboard side aft.
Due 14 July 2004
Resolved 26 July 2004
Resolution: Doors runners were cleaned and greased, per phoncon with [name withheld].
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 July 2004
Resolved
Replace waterlight on ringbouy on portside stack.
Due 14 July 2004
Resolved 7 July 2004
Deck/Cargo › Cargo Stowage › General
Issued 7 July 2004
Resolved
Repair cargo davit hook safety latch.
Due 14 July 2004
Resolved 7 July 2004
Engineering › Compressed Air System (start air) › Valve
Issued 6 April 2004
Resolved
Repair or replace the relief valve for the upper air receiver, valve not set correctly. LEGACY COMPONENT DESC: Valve
Due 6 July 2004
Resolved 7 July 2004
Resolution: Valve replaced.
Accommodation/Occupational Safety › Messroom › Size
Issued 6 April 2004
Resolved
Clean under coolers and equipment in the food service area.
Due 6 July 2004
Resolved 1 November 2004
Resolution: Inspected by [name withheld], cleaning completed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 September 2003
Resolved
Prove proper installation of anchor light in accordance with navrules. LEGACY COMPONENT DESC: Navigation Lights
Due 8 January 2004
Resolved 7 July 2004
Resolution: Owner constructed separate anchor light mast on upper deck stern rail.
Documentation › Markings/Placards
Issued 8 September 2003
Resolved
Label watertight door controls in engineroom-"Manual" and "Hand power".
Due 8 October 2003
Resolved 14 October 2003
Pollution Prevention/Response › Prevention Equipment
Issued 8 September 2003
Resolved
Clean trash and drain water from gear and lube oil fill/vent containment. LEGACY COMPONENT DESC: Fixed Containment
Due 8 October 2003
Resolved 14 October 2003
Electrical › Electric Generation Source (service)
Issued 22 May 2003
Resolved
Demonstrate SSDG reverse power relays.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 8 September 2003
Electrical › Electric Generation Source (service) › Generator
Issued 22 May 2003
Resolved
Demonstrate the load shedding capabilities of the #1,2,3 SSDG to the satisfaction of the attending Marine inspector.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 28 March 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 December 2002
Resolved
Provide QFA, FEMA, ATP to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 1 November 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 December 2002
Resolved
Complete design verification test using an approved procedure for vital systems.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 1 November 2004
Documentation › Safety Management System
Issued 11 December 2002
Resolved
Resubmit periodic test procedures IAW MSC letter dated 08 MAY 2003. LEGACY COMPONENT DESC: Reports and Analysis Procedures
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 2 March 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 11 December 2002
Resolved
Demonstrate local engine control to comply with MSC letter dated 08 May 03 and capability to locally control engines and clutches for prolonged periods.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 1 November 2004
Resolution: Conducted design verification, all sat.
Documentation › Certificates/Documents
Issued 11 December 2002
Resolved
Provide approved Interior Communications drawings IAW 46 CFR 110.25.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 2 March 2004
Documentation › Manuals/Policy Documentation
Issued 11 December 2002
Resolved
Provide short circuit analysis for distribution system IAW 46 CFR 111.52.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 2 March 2004
Documentation › Certificates/Documents
Issued 11 December 2002
Resolved
Resubmit Electrical load analysis of as built vessel electrical system.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 2 March 2004
Documentation › Certificates/Documents
Issued 11 December 2002
Resolved
Resubmit electrical one line diagram for MSC approval prior to 22 Jun 03 reflecting as built condition.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 2 March 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 December 2002
Resolved
Provide engine control arrangement to meet fail safe(ASIS) speed of main engines IAW 46 CFR 62.35-5(e)(3).
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 1 November 2004
Personnel › Training
Issued 11 December 2002
Resolved
Upon arrival to home port, demonstrate Fire Drill, Man overboard/Abandonship drills. LEGACY COMPONENT DESC: Passenger Safety
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 27 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 December 2002
Resolved
Prior to use of the elevator, demonstrate communication.
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 8 September 2003
Electrical › Electrical Distribution System (emergency)
Issued 11 December 2002
Resolved
Relocate EDG manual voltage regulator control to EDG switchboard. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 6 April 2004
Electrical › Electrical Distribution System (emergency)
Issued 11 December 2002
Resolved
Plug hole in Emergency switchboard with proper cover. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 8 September 2003
Electrical › Electrical Distribution System (service)
Issued 11 December 2002
Resolved
Clear ground on 440v main switchboard. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 8 September 2003
Electrical › Electric Generation Source (service)
Issued 11 December 2002
Resolved
Install #1 SSDG manual voltage regulator. LEGACY COMPONENT DESC: Overcurrent Device
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 6 April 2004
Electrical › Electric Generation Source (service)
Issued 11 December 2002
Resolved
Relocate #2 SSDG manual voltage regulator. LEGACY COMPONENT DESC: Overcurrent Device
Action required: 705 - Other - as specified
Due 22 June 2003
Resolved 8 September 2003
Engineering › Steam System (auxiliary)
Issued 11 December 2002
Resolved
Install an interlock preventing the boiler and steam genie from simultanious operation. Due to the vessel's sharing the same exhaust stack. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 7 June 2003
Resolved 8 September 2003