Inspection history · 51
14 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8251402
15 October 2025
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8253117
16 January 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8015642
14 October 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8019771
6 March 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7881173
4 October 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7803197
21 April 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7691345
9 September 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557154
28 July 2022
Deficiency Check · Drydock Extension · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7518645
5 October 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7323641
25 June 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7263677
18 May 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7219399
21 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7039055
14 July 2020
Deficiency Check · Initial Certification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7006261
26 August 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6794809
27 April 2015
Marine Casualty Follow Up
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5111546
24 April 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5110054
24 April 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5111446
5 September 2013
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4707128
5 April 2011
Industry Initiated Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3980212
3 November 2010
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3917003
4 November 2008
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3366767
16 May 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2932686
27 November 2006
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2829355
7 July 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2705749
21 September 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2499324
29 August 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478687
28 April 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2345521
27 April 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2362173
23 November 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2247148
9 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2213016
13 February 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2229904
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973042
24 September 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1911834
23 September 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1911703
5 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1787435
3 August 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1657251
30 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1643338
28 May 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1624386
17 July 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 181631
14 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 682720
29 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 111683
7 March 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 108996
10 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 682711
2 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 69438
18 June 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 75978
8 April 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 682703
1 November 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 682699
26 October 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 160771
30 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 129652
10 June 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 686283
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 November 2025
Resolved
The fire main system must be charged, and sufficient pressure must be verified at the most remote and highest outlets. Port side fire hydrant standpipe had significant pinhole leak once energized. Adequate pressure was still delivered through the fire hose. Current standpipe appears to have past repairs, therefore crop and renew of entire standpipe is necessary for full permanent repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 24 November 2025
Resolution: Received objective evidence from operator that port side fire hydrant standpipe was completely replaced and does not leak when energized. Video shows entire hydrant connected with hose and energized.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 November 2025
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm)). Pressure from the fire pump appeared adequate, however, pressure gauge on the fire pump itself would not give an accurate reading. It would not go above 10 psi. Replace pressure gauge on fire pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 24 November 2025
Resolution: Received objective evidence from operator that new pressure gauge was replaced on fire pump and is displaying adequate pressure while fire pump is running.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 October 2024
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel is overdue for her Annual Inspection as of 13OCT24. Vessel must obtain a valid COI prior to conducting towing operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 January 2025
Resolved 16 January 2025
Resolution: Issued COI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Vessels Shore power indicator light and Port Generator light covers on the switchboard were missing. Replace light covers in accordance with manufacturer instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 2 November 2023
Resolution: light cover replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Electrical wire connections above the port engine was missing a cover on the junction box. Replace cover on junction box to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 2 November 2023
Resolution: cover has been replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Notice raw gauge and jacket water gauge on the Port Engine were broken. Replace gauges in accordance with manufactures instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2023
Resolved 2 November 2023
Resolution: Guages have been replaced