RENOWN

RENOWN is a 1940 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1984, most recently in April 2020, along with 142 deficiencies — 17 with no resolution recorded —, 1 operational control, 1 with no removal date recorded and 5 casualty investigations between 2002 and 2010.

Records from 1984 to 2020. Most recent: inspection, 22 April 2020.

Built
1940
Last inspected
22 April 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WAJ2248
Flag
UNITED STATES
367015810 (licence lapsed)
Maury page id
psix-60930

Inspections, by type

…with no type recorded14
…past their stated due date1
Years with a record 35 calendar years (1984–2020)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.4 ft × 16.0 ft × 8.1 ft
Registered tonnagegross 73 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMATHIS YACHT BUILDING COMPANY · CAMDEN, NJ, UNITED STATES · built 1940
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAJ2248MMSI 367015810 · expired · compulsorily equipped · granted 19 February 2015, cancelled 3 May 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

EMERALD HORNBLOWER Passenger (Inspected) · MISLE 400746 · 20 February 2005 · activity 2308512

Inspection history · 94

22 April 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6942359
29 January 2020 Administrative Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6898630
22 January 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6893856
6 February 2019 Annual Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6621184
21 February 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359167
12 February 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6356469
18 January 2018 Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6339367
22 November 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6306534
15 February 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6088780
12 January 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5796256
12 November 2015 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5761966
15 May 2012 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4329159
25 January 2012 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4219907
1 December 2011 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4196836
1 December 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4199701
7 December 2010 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3884091
2 October 2010 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3861561
1 October 2010 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3894367
12 January 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3646538
16 December 2009 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3645865
3 December 2008 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3349372
21 June 2008 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3254925
3 January 2008 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3115686
5 December 2007 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3089131
11 January 2007 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2907784
4 January 2006 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2559866
8 December 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2528503
24 February 2005 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2298120
20 February 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2308512
9 December 2004 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2239798
11 December 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1945473
11 December 2003 Examination of Repairs · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1962840
4 November 2003 Drydock Extension · Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1924775
27 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1723331
17 December 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1717779
24 January 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1482464
3 January 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1475294
29 November 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1444621
13 February 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1058060
4 January 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406848
23 July 2000 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 820219
22 July 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 70075
25 January 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1049113
30 December 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393302
30 September 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1449272
6 May 1999 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1456692
26 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 151587
29 January 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1463430
26 January 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1124176
7 January 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471543
8 January 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409815
29 April 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374977
3 January 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1363932
20 August 1996 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1447613
23 April 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1080089
4 January 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1432993
11 May 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 105453
20 April 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1459174
11 January 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387697
3 August 1994 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1358496
14 January 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1162656
9 November 1993 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 848355
29 March 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1423762
15 January 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 829706
14 September 1992 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1261975
23 January 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370461
16 January 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 950768
1 March 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1237089
28 January 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1229672
22 January 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1210888
15 February 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1232747
31 January 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 922500
23 January 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284076
4 January 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 924075
12 December 1989 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1231603
25 August 1989 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1207848
30 June 1989 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1208350
6 June 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1196254
24 May 1989 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 897057
14 February 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1345003
8 February 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1032875
10 February 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1327225
1 December 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1308851
8 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1027539
7 April 1987 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1332619
18 February 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1321848
5 December 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1026539
4 November 1986 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1012754
14 March 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996328
18 February 1986 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295092
23 November 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295685
28 February 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 978357
28 February 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1285942
20 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1285940

Deficiency record · 142

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2020 No resolution recorded
Vessels exposed to salt water more than 3 months in any 12 month period must undergo a drydock and internal structural examination at least once every 2 years. The vessel failed to complete the required drydock and internal structural examination in accordance with 46CFR176.600(b)(1). The vessel is not permitted to carry passengers for hire until satisfactory completion of the required drydock and internal structural examination.
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020 No resolution recorded
Install emergency lighting in all spaces below the main deck accessible to passengers/crew; emergency lighting shall automatically activate upon failure of the main lighting system. Due prior to credit hull. Old-T 46CFR184.30-5.
Condition: Improper Installation
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 January 2020 No resolution recorded
Renew rotten sheer clamp, port side galley. Due prior to credit hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 January 2020 No resolution recorded
Renew rotten frames and hull at galley starboard side window (remove coverings for further inspection). Due prior to credit hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 January 2020 No resolution recorded
Renew rotten hatch at forward escape. Due prior to credit hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 January 2020 No resolution recorded
Replace broken window in forward escape trunk, port side. Due prior to credit hull.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 January 2020 No resolution recorded
Renew rotten deck, port side main deck at galley/sheer clamp. Due prior to credit hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 January 2020 No resolution recorded
Install non combustible waste receptacles in passenger lounge areas. Due 22Feb2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 January 2020 No resolution recorded
Provide repair plan for fixed bilge system - system shall contain manifold with individual stop valves, check valves, and strainers for each suction line. System is to be operationally tested after repairs, due prior to carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2020 No resolution recorded
Provide repair plan for fuel piping arrangements meeting the requirements in 46CFR182.455. System is to be operationally tested following repairs, prior to carriage of passengers.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2020 No resolution recorded
Install permanent fuel vent flame screen at vent terminus; minimum 30x30 mesh. Due prior to credit hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020 No resolution recorded
Install outlet cover on galley hot plate outlet. Due 22Feb2020.
Condition: Improper Installation
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 January 2020 No resolution recorded
Make three (03) electrical j-boxes on cabin top above wheel house water tight. Due prior to credit hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 January 2020 No resolution recorded
Remove obstruction (light strip) from port side galley window. Due prior to credit hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 January 2020 No resolution recorded
Renew rotten overhead in wheel house under port side running light. Due prior to credit hull.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 22 January 2020 No resolution recorded
Crop and renew aft water tight bulkhead where wasted; make bulkhead water tight. Due prior to credit hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 February 2019 Resolved
Provide vessel with 03 additional flares
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019 Resolved
Terminate open wires in junction box on vessel's stern
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 6 February 2019 Resolved
Remove all oily water from eninge room and galley bilges
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2019 Resolved
Label life jacket stowage on vessel's bow
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2019
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 February 2019 Resolved
Complete underway drills with full crew onboard
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 12 April 2019
Resolution: Drills conducted.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 February 2019 Resolved
Properly mount steering pump accumulator
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 12 April 2019
Resolution: Pump mounted.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 February 2019 Resolved
Renew 02 kinked steering control pipes
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 12 April 2019
Resolution: REplaced w/ hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2019 Resolved
Renew 02 generator fuel hoses
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 12 April 2019
Resolution: Hoses replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 6 February 2019 Resolved
Properly mount fire pump
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 12 April 2019
Resolution: Pump mounted.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 6 February 2019 Resolved
Provide one-line diagram of new battery charger power
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 18 June 2019
Resolution: Vessel rep provided drawing, loaded drawing into activity documents.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 6 February 2019 Resolved
Provide one-line diagram of new throttle control power
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 18 June 2019
Resolution: Vessel rep provided drawing, loaded drawing into activity documents.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 6 February 2019 Resolved
Provide MSC approved PSTP's and DVTP's for propulsion throttle controls
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 22 April 2020
Resolution: Received approval letter from MSC.
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 21 February 2018 Resolved
Demonstrate proper operation of propulsion system due to repeated loss of propulsion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2018
Resolved 23 February 2018
Resolution: Electrical ground found. All new wiring from engine to helm controls installed.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 21 February 2018 Resolved
Provie proper operation of both MDE temp guages.
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 23 February 2018
Resolution: Gauges rewired.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 12 February 2018 Resolved
Demonstrate proper operation of vessel shaft. Make available for inspection prior to operations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2018
Resolution: Seatrails conducted. Did not see vessel in dry dock due to operator leaving before CG arrived.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 15 February 2017 Resolved
Provide master with valid marine radio operators permit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2017
Resolved 15 February 2017
Resolution: GMDSS Radio operators license provided.
Engineering › Steering Gear System › Piping
Issued 15 February 2017 Resolved
Remove bucket of hydraulic oil under helm.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 9 March 2017
Resolution: Bucket removed.
Engineering › Steering Gear System › Piping
Issued 15 February 2017 Resolved
Cap hydraulic lines under helm.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 9 March 2017
Resolution: Lines capped.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 February 2017 Resolved
Replace battery in lifebuoy light with approved type.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 9 March 2017
Resolution: Battery replaced.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 February 2017 Resolved
Update placard for child lifejackets.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 9 March 2017
Resolution: Placard updated.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 February 2017 Resolved
Provide blank in engineroom swithcboard.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 9 March 2017
Resolution: Blank provided.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 February 2017 Resolved
Ensure sewage valve is locked while not pumping sewage.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 24 February 2017
Resolution: Locked valve.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2017 Resolved
Cap exposed wires on port engine.
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 9 March 2017
Resolution: Wiring capped.
Stability › Incline Test › General
Issued 15 February 2017 No resolution recorded
Vessel is not permitted to carry passengers with the canopy structure installed over the aft cockpit. Prove vessel is in compliance with current stability letter. Vessel made unauthorized alteration to stern portion of vessel by adding awning.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 November 2015 Resolved
Provide Portable emergency flashlight for pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 20 November 2015
Resolution: Emergency light provided
Engineering › Fuel Oil Service System › Filter
Issued 12 November 2015 Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 20 November 2015
Resolution: A marine grade fuel filter was provided.
Construction/Loadline › Structures › End Bulkhead
Issued 12 November 2015 Resolved
Make forward engine room bulkhead fumetight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 20 November 2015
Resolution: Forward bulkhead is now water tight
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Communications › Alarms/Indicators › High Water Alarm
Issued 1 December 2011 Resolved
Renew or prove proper operation of the port main engine water temp gauge at the operating station.
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 4 January 2012
Engineering › Fuel Oil Service System › Valve
Issued 1 December 2011 Resolved
Properly label fuel remote shut off valves.
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 4 January 2012
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 1 December 2011 Resolved
Label port pights in the engine room "CLOSE WHEN ENGINES ARE RUNNING"
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 4 January 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 28 November 2011 Resolved
Remove old galley light fixture and wiring or prove proper operation.
Action required: 705 - Other - as specified
Due 1 January 2012
Resolved 4 January 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 December 2010 Resolved
Provide updated publications as per 46 CFR 184.420
Condition: Invalid
Due 7 January 2011
Resolved 5 January 2011
Resolution: Updated all pubs as per 46 CFR 184.420
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 December 2010 Resolved
Provide 06 type I lifejackets to replace the 06 that failed inspection. Restricted to 59 adult adult passengers until replaced.
Due 7 January 2011
Resolved 5 January 2011
Resolution: Replaced 06 type 1 lifejackets.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 December 2009 Resolved
Replace expired aspirin in first aid kit.
Condition: Improper/Lack of Maintenance
Due 30 December 2009
Resolved 6 January 2010
Resolution: Replaced expired aspirin.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 December 2009 Resolved
Provide permanent cap or valve on thru hull located in the crews head.
Condition: Improper/Lack of Maintenance
Due 30 December 2009
Resolved 6 January 2010
Resolution: Installed permanent cap on thru hull.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 December 2009 Resolved
Provide guard for port engine belt pulley.
Due 30 December 2009
Resolved 6 January 2010
Resolution: Installed guard for port engine belt pulley.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 16 December 2009 Resolved
Provide cover for external shore tie connection on STBD side.
Condition: Unknown
Due 30 December 2009
Resolved 6 January 2010
Resolution: Installed cover on shore tie connection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 December 2009 Resolved
Conduct annual service on Fire boy located inside generator enclosure.
Condition: Improper/Lack of Maintenance
Due 30 December 2009
Resolved 6 January 2010
Resolution: Conducted annual service on fire boy.
Fire Fighting › Fire Main › Condition
Issued 16 December 2009 Resolved
Provide permanent repair on leaking fire main piping in engine room.
Condition: Unknown
Due 30 December 2009
Resolved 8 January 2010
Resolution: Repaired leaking fire main piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 3 December 2008 Resolved
Provide instructions procedures to operate engines and reduction gears locally in the event pilot house control air is lost. 46 CFR 184.620 (a)
Due 12 December 2008
Resolved 19 December 2008
Resolution: Procedures/instructions posted, crew trained on procedures, demonstrations of procedures performed to attending MI''''''''s satisfaction.
Construction/Loadline › Hull › Side Shell
Issued 3 December 2008 Resolved
Provide repair proposal for STBD transom surface damage.
Due 3 January 2009
Resolved 23 January 2009
Resolution: Repair made to satisfaction of marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 December 2008 Resolved
Replace 18 adult size and 1 child size life preservers for a total of 65 adult and 7 child preservers IAW 46 CFR 180.71. Vsl is restricted to carrying 47 adults and 6 children until corrected.
Action required: 705 - Other - as specified
Resolved 4 December 2008
Resolution: Replaced required life preservers as listed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 December 2008 Resolved
Replace 1 water light due to crack in body of light. 46 CFR 180.71. Vsl is restricted to day time operation until corrected.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 4 December 2008
Resolution: Replaced with new light.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 December 2008 Resolved
Install high level bilge alarm in lazarette. 46 CFR 182.530
Due 3 January 2009
Resolved 19 December 2008
Resolution: Installed high level indicating float switch alarm.
Engineering › Steering Gear System › Chain
Issued 21 June 2008 Resolved
Affect permanent repair to steering system and complete satisfactory check-ride in presence of CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2008
Resolved 21 June 2008
Resolution: Removed broken cable, replaced w/ new, & lubricated all roller guides.
Engineering › Steering Gear System › Chain
Issued 21 June 2008 Resolved
Replace worn starboard steering cable to even tension on system w/ new port cable.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 27 June 2008
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 21 June 2008 Resolved
Provide documented system of preventive maintenance and daily pre-operational testing of steering system to include visual observation of cable condition during tests, and to include accountability verification.
Action required: 705 - Other - as specified
Due 21 July 2008
Resolved 1 August 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 April 2008 Resolved
Label fore peak bilge alarm on panel.
Due 24 April 2008
Resolved 28 April 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 April 2008 Resolved
Remove bilge alarm "mute" switch on bilge alarm panel. Bilge alarms must give audible and visual indication at all times. Switch must be in "bell" mode at all times until removed.
Due 24 April 2008
Resolved 28 April 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 17 April 2008 Resolved
Remove semi-permanent fan in galley port hole and submit proposal for permanent ventilation arrangement. Crew continues to install port hole fan, existing natural ventilation is probably not adequate.
Due 24 April 2008
Resolved 24 July 2008
Resolution: New exhaust hose was install, placard was made to secure port hole when leaving the bay, orginal requirement was not required.
Engineering › Bilge Water Management System › Valve
Issued 16 January 2008 Resolved
Free up fore peak bilge bulkhead valve.
Due 16 February 2008
Resolved 29 February 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 16 January 2008 Resolved
Provide proposal to properly duct food warmer/oven unit.
Due 16 February 2008
Resolved 24 July 2008
Resolution: Proposal was submitted, but is not required
Construction/Loadline › Penetrations › Valve Flange
Issued 3 January 2008 Resolved
Replace fire pump though hull valve.
Action required: 705 - Other - as specified
Resolved 11 January 2008
Construction/Loadline › Hull › Keel
Issued 3 January 2008 Resolved
Pull marked fasteners and 1 keel bolt.
Action required: 705 - Other - as specified
Resolved 11 January 2008
Construction/Loadline › Hull › Side Shell
Issued 3 January 2008 Resolved
Repair crack on starboard side wood underneath strut.
Action required: 705 - Other - as specified
Resolved 14 January 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 January 2008 Resolved
Replace ban strap on lower transom.
Action required: 705 - Other - as specified
Resolved 14 January 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 January 2008 Resolved
Replace frame blocks in galley, port and starboard.
Action required: 705 - Other - as specified
Resolved 11 January 2008
Construction/Loadline › Structures › Deck Plating
Issued 3 January 2008 Resolved
Repair or replace floor support frame underneath shower fire ext. box.
Action required: 705 - Other - as specified
Resolved 14 January 2008
Construction/Loadline › Structures › End Bulkhead
Issued 3 January 2008 Resolved
Repair/replace lower bulkhead penetrations in all lower frames of the ship.
Action required: 705 - Other - as specified
Resolved 14 January 2008
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 3 January 2008 Resolved
Remove both props and repair damaged blades.
Action required: 705 - Other - as specified
Resolved 11 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 December 2007 Resolved
Install proper bulbs in Port and Starboard nav lights. Correct prior to operating at night or during reduced visibility.
Due 19 December 2007
Resolved 16 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 December 2007 Resolved
Replace lens on Starboard nav light.
Due 19 December 2007
Resolved 16 January 2008
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 5 December 2007 Resolved
Secure hot plate and repair element.
Due 19 December 2007
Resolved 17 April 2008
Resolution: Hot plate removed.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 December 2007 Resolved
Seal bulkhead penetrations, fwd E/R bhd, to make vapor tight.
Due 19 December 2007
Resolved 29 February 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 December 2007 Resolved
Replace (10) adult and (1) child Type 1 PFD's. Vsl restricted to not more than (55) total persons, (6) children, until corrected.
Due 19 December 2007
Resolved 29 February 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 December 2007 Resolved
Repair water light for lifebuoy. Correct prior to operating at night or during reduced visibility
Due 19 December 2007
Resolved 16 January 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 December 2007 Resolved
Provide boxes for all batteries.
Due 19 December 2007
Resolved 16 January 2008
Construction/Loadline › Structures › Ventilators
Issued 5 December 2007 Resolved
Repair all portholes to make watertight.
Due 4 January 2008
Resolved 29 February 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 December 2007 Resolved
Re-install secondary means of escape (ladder) from fwd pantry.
Due 19 December 2007
Resolved 16 January 2008
Fire Fighting › Fire Pumps › Pressure
Issued 5 December 2007 Resolved
Repair fire pump to provide at least 60psi of pressure.
Due 19 December 2007
Resolved 16 January 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 December 2007 Resolved
Install bilge alarm in fore peak. Ensure penetrations for wires are kept as high and center as possible and remain water tight.
Due 16 February 2008
Resolved 17 April 2008
Electrical › Electric Supply System (service)
Issued 17 December 2002 Resolved
Shore cable cracked and wasted. Must be replaced or renewed. IAW 46 CFR 183.390 LEGACY COMPONENT DESC: Cable
Due 17 January 2003
Resolved 24 January 2003
Electrical › Lighting (service)
Issued 17 December 2002 Resolved
Permanately mount motor atop of hot water heater. IAW 46 CFR 183.220
Due 17 January 2003
Resolved 24 January 2003
Accommodation/Occupational Safety › Heating › Radiator
Issued 17 December 2002 Resolved
Band Hot water heater to bulkhead. IAW 46 CFR 182.320
Due 17 January 2003
Resolved 19 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 17 December 2002 Resolved
Relocate emergency escape sign. IAW 46 CFR 185.606
Due 17 January 2003
Resolved 19 December 2002
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 December 2002 Resolved
Must install dead front on Nav. marking switch panel. IAW 46 CFR 183.320
Due 17 January 2003
Resolved 19 December 2002
Operations/Management › Lifesaving
Issued 17 December 2002 Resolved
MOB Drill- Spotter location, rescue platform, crews preperation of rescue platform and crew must prep rescue area prior to retrival. An announcement to all passengers and donning of life jackets is required by all crew members. IAW 46 CFR 185.520 LEGACY COMPONENT DESC: MOB Drill
Due 17 January 2003
Resolved 19 December 2002
Operations/Management › FireFighting
Issued 17 December 2002 Resolved
Fire Drill- Must secure ventilation, needs to discuss steering options and must take managerial control of passengers. IAW 46 CFR 185.520 LEGACY COMPONENT DESC: Fire Drill
Due 17 January 2003
Resolved 19 December 2002
Navigation › Electronic Positioning
Issued 4 January 2002 Resolved
Repair compass light at operating station. LEGACY COMPONENT DESC: Compass Light
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 4 January 2002
Stability › Watertight Integrity
Issued 4 January 2002 Resolved
Remove water from bilges in galley and main state room. LEGACY COMPONENT DESC: Water in bilges
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 15 January 2002
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 4 January 2002 Resolved
Provide 30 X 30 mesh for fuel tank vents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 4 January 2002
Deck/Cargo › Holds/Tanks
Issued 4 January 2002 Resolved
Attach captive chain to aft steering hatch cover. LEGACY COMPONENT DESC: Hatch
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 15 January 2002
Engineering › Bilge Water Management System
Issued 29 November 2001 Resolved
Demonstrate proper operation of bilge high level alarms. LEGACY COMPONENT DESC: high level bilge alarm
Action required: 705 - Other - as specified
Due 30 November 2001
Resolved 30 November 2001
Electrical
Issued 4 January 2001 Resolved
BATTERY BOXES IN MACHINERY SPACE WASTED AND MISSING CORROSION RESISTENT TRAY.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Lifesaving
Issued 4 January 2001 Resolved
MISSING RESCUE HARNESS LISTED IN VESSEL'S EMERGENCY INSTRUCTIONS FOR MAN OVERBOARD RESCUE.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 4 January 2001 Resolved
INTERIOR DECORATIVE LIGHTS CREATE EXCESSIVE HEAT AND MAY CAUSE BURNS UPON CONTACT. WIRING INSIDE LIGHT ALSO SHOWING SIGNS OF FAILURE DUE TO EXCESSIVEHEAT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Accommodation/Occupational Safety
Issued 4 January 2001 Resolved
FORWARD RAIL COURSES EXCEED 12" SPACING REQUIREMENT.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Navigation
Issued 4 January 2001 Resolved
EXPIRED CHARTS AND PUBLICATIONS
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Navigation
Issued 23 July 2000 Resolved
Renew steering cable as discussed. Test in the presence of and to the satisfaction of attending USCG Marine Inspector. Do not take passengers for hire prior to approval of OCMI rep.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Navigation
Issued 30 December 1999 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Lifesaving
Issued 30 December 1999 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Construction/Loadline
Issued 30 December 1999 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Construction/Loadline
Issued 30 December 1999 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Lifesaving
Issued 30 December 1999 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Lifesaving
Issued 30 September 1999 Resolved
SECURE/REFASTEN STANCHIONS AND CAP RAIL AS NECESSARY.
Condition: Unknown
Due 15 November 1999
Resolved 9 December 1999
Construction/Loadline
Issued 30 September 1999 Resolved
MAKE REPAIRS/REPLACE ROTTEN FRAME MEMBER, STARBOARD SIDE IN STEERING SPACE.
Condition: Unknown
Due 15 November 1999
Resolved 9 December 1999
Unknown
Issued 30 September 1999 Resolved
FORWARD CLEAT BOLTS MUST REACH RULL DEPTH OF NUTS.
Condition: Unknown
Due 15 November 1999
Resolved 9 December 1999
Construction/Loadline
Issued 7 January 1999 Resolved
Repair broken glass windows on sides of vessel by 21JAN99.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Electrical
Issued 7 January 1999 Resolved
Secure wiring in way of engine room with metal bands by 21JAN99.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Documentation
Issued 16 January 1992 Resolved
PROVIDE DOCUMENTATION TO SUPPORT THE DRUG AND ALCOHOL TESTING PROGRAM OF VESSEL'S PRESONNEL IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Documentation
Issued 16 January 1992 Resolved
PROVIDE A CERTIFICATE OF DOCUMENTATION ON BOARD WITH VALID RENEWAL STICKER AFFIXED.
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Electrical
Issued 16 January 1992 Resolved
REPAIR ONE(1) EMERGENCY LIGHT IN THE GALLEY. _x001C_ _x001C_ _x001C_ X
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Fire Fighting
Issued 16 January 1992 Resolved
RENEW OR REPAIR THE FIRE PUMP GAUGE IN THE ENGINE ROOM.
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Construction/Loadline
Issued 16 January 1992 Resolved
REPAIR THE BILGE AUDIBLE ALARM AND PROVE THE PROPER OPERATION.
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Navigation
Issued 22 January 1991 Resolved
GET VESSEL UNDERWAY IN A "WORST CASE" SITUATION AND CONDUCT DRILLS TO THE_x001C_ SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Electrical
Issued 22 January 1991 Resolved
PROVIDE 4 DOUBLE BREAKER BLANKS AND 4 SINGLE BREAKER BLANKS IN MAIN _x001C_ ELECTRICAL PANEL.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Fire Fighting
Issued 22 January 1991 Resolved
PROVIDE A HAND OPERATED FIRE/BILGE PUMP
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Engineering
Issued 22 January 1991 Resolved
PROVIDE FUEL TANK VENT FLAME SCREENS AT ALL TANK VENTS.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Engineering
Issued 23 January 1990 Resolved
ELIMINATE ASBESTOS DUST CONTAMINATION OR EXPOSURES IN WAY OF THE ENGINE ROOM DRY EXHAUST SYSTEM. TO BE CORRECTED NO LATER THAN THE VESSEL'S NEXT DRYDOCKING SCHEDULE.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Engineering
Issued 23 January 1990 Resolved
PROVIDE SAFETY GUARD COVER TO POWER TAKE OFF BILGE PUMP IN WAY OF MAIN DIESEL ENGINE PORTSIDE.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Fire Fighting
Issued 23 January 1990 Resolved
PROVIDE ONE (1) B-II PORTABLE FIRE EXTINGUISHER FOR MAIN DECK LOUNGE AREA PROTECTION. TO BE CORRECTED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Fire Fighting
Issued 23 January 1990 Resolved
PROVIDE ONE FIRE AX ON BOARD. TO BE CORRECTED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Unknown
Issued 6 June 1989 Resolved
CLEAN ENGINEROOM BILGES FREE OF OIL RESIDUE AT NEXT DRYDOCKING.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Unknown
Issued 24 May 1989 Resolved
CLEAN BILGES IN THE ENGINEROOM FREE OF OIL RESIDUE.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Unknown
Issued 8 February 1989 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Lifesaving
Issued 8 February 1989 Resolved
REPLACE LINES ON LIFE RING BUOY WITH A 60 FEET POLYPROPHYLINE LINES.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Engineering
Issued 10 February 1988 Resolved
SECURE MAIN PROPULSION DIESEL RAW WATER COOLING DISCHARGE LINE TO OVERBOARDDISCHARGE VALVE WITH DOUBLE CLAMP.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Engineering
Issued 10 February 1988 Resolved
SECURE BILGE PUMP DISCHARGE LINE TO OVERBOARD DISCHARGE VALVE WITH DOUBLE CLAMP.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Electrical
Issued 10 February 1988 Resolved
INSTALL FREQUENCY METER FOR THE SHIP SERVICE GENERATOR.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Unknown
Issued 18 February 1987 Resolved
INSTALL A COAST GUARD APPROVED MARINE SANITATION DEVICE, AFTER SUBMITTING AND OBTAINING APPROVAL OF PLANS AND SPECIFICATIONS FOR INSTALLATION OF SAME.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Construction/Loadline
Issued 18 February 1987 Resolved
REPLACE BROKEN GLASS IN PORT HOLE IN WAY OF HEAD, STARBOARD SIDE.
Condition: Unknown
Due 18 February 1987
Resolved 18 February 1987
Construction/Loadline
Issued 4 November 1986 Resolved
REFASTEN WORM SHOE IN AFT AREA OF KEEL
Condition: Unknown
Due 4 November 1986
Resolved 4 November 1986
Construction/Loadline
Issued 4 November 1986 Resolved
SUBMIT PROPOSAL TO PLUMB GRAY WATER INTO HOLDING TANK
Condition: Unknown
Due 4 November 1986
Resolved 4 November 1986
Construction/Loadline
Issued 4 November 1986 Resolved
RENEW AREA OF WORM SHOE AFT OF STEM
Condition: Unknown
Due 4 November 1986
Resolved 4 November 1986

Casualty record · 5

24 January 2002Routine · role: Involved in a Marine Casualty · activity 1482464
27 December 2002Routine · role: Involved in a Marine Casualty · activity 1723331
20 February 2005Routine · role: Involved in a Marine Casualty · activity 2308512
26 August 2009Routine · role: Involved in a Marine Casualty · activity 3579347
1 October 2010Routine · role: Involved in a Marine Casualty · activity 3894367
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.